DiVA portal946975/FULLTEXT01.pdf · ii Industrial Pilot Scale Leaching and Recovery of Zinc from...
Transcript of DiVA portal946975/FULLTEXT01.pdf · ii Industrial Pilot Scale Leaching and Recovery of Zinc from...
This thesis comprises 60 ECTS credits and is a compulsory part in the Master of Science
with a Major in Resource Recovery – Sustainable Engineering, 120 ECTS credits
No. 2016.13.06
Industrial Pilot Scale
Leaching and Recovery of Zinc from Waste-to-
Energy Fly Ash using Scrubber Liquids
Manuela Wagner
ii
Industrial Pilot Scale Leaching and Recovery of Zinc from Waste-to-Energy Fly Ash
using Scrubber Liquids
Manuela Wagner, [email protected]
Master thesis
Subject Category: Technology
University of Borås
School of Engineering
SE-501 90 BORÅS
Telephone +46 033 435 4640
Examiner: Dr. Anita Pettersson
Supervisor, name: Dr. Karin Karlfeldt Fedje Dr. Sven Andersson
Supervisor, address: Renova AB Götaverken Miljö AB
Box 156 Anders Carlssons gata 14
401 22 Göteborg 417 55 Göteborg
Date: 2016-06-03
Keywords: pilot plant, zinc recovery, fly ash, WtE, scrubber liquids, leaching, precipitation, chlorides
iii
Abstract
Previous studies from laboratory experiments and a similar process at a plant in Switzerland, led to the pilot plant project at Renova AB, which will be described in this master thesis. In cooperation with Götaverken Miljö AB it was investigated if fly ash, produced at the Renova Waste-to-Energy plant in Gothenburg, could be treated with own scrubber liquids in order to recover zinc. If successful, Renova might build this tested pilot process in to a big scale. The pilot plant has a scale of 16 times smaller than a future big scale process. The goal of the project is to leach zinc from fly ash and gain a fly ash residue, which is classified as non-hazardous waste. The filtrate from the leaching campaign is treated so that the containing zinc is recovered. The zinc cake end product shall has a quality so that it can be sold to other industries or upgraded to high purity zinc metal. The evaluation of the experiments showed that the pilot plant process was successful. It was possible to leach out zinc by a maximum quote of 74%. The total recovery of zinc could be achieved by a maximum of 72%. The final zinc cake product was achieved through a precipitation and filtration campaign. This thesis evaluates, which process set-ups for zinc recovery through leaching and precipitation & filtration are the best and can be recommended for a big scale process. In addition, it briefly analyses the zinc product quality. Future studies will be necessary within: cost analysis of the process, zinc product quality and an analysis of the ash residue. Keywords: pilot plant, zinc recovery, zinc hydroxide, fly ash, WtE, scrubber liquids, leaching, precipitation, filtration
iv
Table of contents
Abstract .................................................................................................................................... iii
Table of Figures ....................................................................................................................... vi
Table of Tables ...................................................................................................................... viii
Table of Abbreviations ............................................................................................................ ix
1. Introduction ...................................................................................................................... 1
2. Background ....................................................................................................................... 2
3. Description of the Waste-to-Energy Process at Renova ............................................... 4
4. Material ............................................................................................................................. 6
4.1 Fly Ash ......................................................................................................................... 6
4.2 Scrubber liquids ........................................................................................................... 7
4.2.1 Hydrochloric acid ............................................................................................... 7
4.2.2 Sodium sulphate solution .................................................................................... 8
4.2.3 Condensate water ................................................................................................ 8
4.3 Other liquids ................................................................................................................. 8
4.3.1 Sulphuric acid ..................................................................................................... 8
4.3.2 Sodium Hydroxide .............................................................................................. 9
5. Pilot Plant Principle ......................................................................................................... 9
6. Laboratory experiments ................................................................................................ 11
6.1 Laboratory Set-up....................................................................................................... 11
6.2 Zn-Precipitation Method in Laboratory ..................................................................... 13
7. Pilot Plant: Leaching Campaign ................................................................................... 14
7.1 Leaching Set-up ......................................................................................................... 14
7.2 Leaching Method ....................................................................................................... 17
8. Pilot Plant: Precipitation and Filtration Campaign.................................................... 20
8.1 Precipitation and Filtration Set-up ............................................................................. 21
8.2 Precipitation and Filtration Method ........................................................................... 22
9. Results and Discussion ................................................................................................... 27
9.1 Pilot Plant Leaching ................................................................................................... 27
9.2 Laboratory Precipitation and Filtration ...................................................................... 30
9.3 Pilot Plant: Precipitation and Filtration ...................................................................... 32
9.4 Total zinc recovery from the pilot plant ..................................................................... 35
v
9.5 Zinc cake end product from the pilot plant ................................................................ 36
10. Conclusion ................................................................................................................. 39
11. Outlook ...................................................................................................................... 40
References ................................................................................................................................ ix
Appendix 1: Calculations....................................................................................................... xii
Appendix 2: Eurofins Result Tables
Appendix 3: Tables from Excel
vi
Table of Figures
Figure 1.1: Municipal Solid Waste Treatment Methods World-Wide & Sweden 1
Figure 3.1: Simplified WtE and Flue Gas cleaning process 5
Figure 4.1: Fly ash from 2 different samples 6
Figure 4.2: Average composition of the used fly ash in percent by weight 7
Figure 4.3: HCl appearance and average composition in percent by weight 7
Figure 4.4: Sodium Sulphate Solution average composition in percent by weight 8
Figure 5.1: a) Leaching Principle b) Pilot Plant Pictures of Leaching Process 10
Figure 5.2: a) Principle of Precipitation b) Pilot Plant Pictures of Precipitation Process 11
Figure 6.1: Scheme of Laboratory Set-Up 12
Figure 6.2: Laboratory Equipment 12
Figure 7.1: Big bag on big bag cutter 15
Figure 7.2: Blending tank during leaching 15
Figure 7.3: Leaching Process Set-up 16
Figure 7.4: Inside of the vacuum belt filer with ash residue and washing procedure 17
Figure 8.1: Precipitation of Heavy Metal Hydroxides 20
Figure 8.2: Precipitaion of Zinc and other metals 21
Figure 8.3 Set-up of Precipitation and Filtration Process 22
Figure 8.4: Warming procedure of Zinc Liquid in Cipax tank 23
Figure 8.5: Flotation procedure of Zinc Liquid in Cipax Tank 23
Figure 9.3: Leaching result of Zinc from Fly Ash 27
Figure 9.4: Zinc leaching efficiency over pH 28
Figure 9.5: Leaching efficiency of Zinc and Magnesium over pH 28
Figure 9.6: Zinc leaching efficiency over L/S 29
Figure 9.7: Zinc leaching efficiency over Residence time 29
Figure 9.1: Zinc precipitation and filtration rate in laboratory 31
Figure 9.2: Magnesium precipitation and filtration rate in laboratory 31
Figure 9.8: Precipitation and Filtration rate: Zinc 32
Figure 9.9: Zinc Precipitation and Filtration rate over pH 33
Figure 9.10: Zinc Precipitation and Filtration over pH + prefill 33
Figure 9.11: Zinc Precipitation and Filtration over Flocculent 34
Figure 9.12: Zinc Precipitation and Filtration over zinc cake formation time 34
vii
Figure 9.13: Zinc Precipitation and Filtration over zinc cake wash time 34
Figure 9.14: Total zinc recovery from fly ash to zinc cake 35
Figure 9.15: Average composition of the wet zinc cake end product 36
Figure 9.16: Average composition of the dry zinc cake end product 36
viii
Table of Tables
Table 6.1: Overview over Laboratory variations 13
Table 6.2: Overview over Laboratory sample preparation 14
Table 7.1: Overview of Leaching Variations 18
Table 7.2: Leaching Campaign with Hydrochloric Acid A, B, C, G, H, J 18
Table 7.3: Leaching Campaign with Hydrochloric Acid and Sodium Sulphate Solution D, F
19
Table 7.4: Leaching Campaign with Hydrochloric Acid and Condensate I 19
Table 7.5: Leaching Campaign with Sulphuric Acid and Condensate K 19
Table 7.6: Leaching Campaign with Condensate E 20
Table 8.1: Overview of Precipitation and Filtration variations 26
Table 9.1: Laboratory results: zinc and magnesium precipitation 31
Table 9.2: Zinc win from 10 kg virgin fly ash 35
Table 9.3: Composition of dry zinc cake end product per campaign 37
Table 9.4: Parameters, influencing the zinc cake product quality 38
ix
Table of Abbreviations
HCl Hydrochloric acid
H2O2 Hydrogen peroxide L/S Liquid to solid ratio
MSWI Municipal Solid Waste Incineration
NaOH Sodium hydroxide Na2SO4 Sodium sulphate solution P&F Precipitation and Filtration
wt% Percent by weight WtE Waste-to-Energy
1
Municipal Solid Waste Treatment Methods
1. Introduction
Living in a “throwaway society”, the amount of solid household waste steadily increases. Whereas Sweden and other European countries have strict legacies on how waste is handled, most other countries world-wide still simply dump their waste in the nature or on uncontrolled landfills (Hoornweg & Bhada-Tata 2012). As consequence, waste liquids drain into ground water and methane gas emits in the atmosphere. Based on the data from Hoornweg & Bhada-Tata (2012) What a Waste – A global review of solid waste management, figure 1.1 shows that Waste-to-Energy (WtE) is the most common waste treatment method in Sweden with 50%. Whereas, taking the average of all other countries, dumping and landfilling (19% & 52%) are far more common world-wide than WtE (4%).
* World-Wide means: Algeria, Antigua and Barbuda, Armenia, Australia, Austria, Belarus, Belgium, Belize, Bulgaria, Cambodia, Cameroon, Canada, Chile, Colombia, Costa Rica, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Dominica, Greece, Grenada, Guatemala, Guyana, Haiti, Hong Kong, China, Hungary, Iceland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Korea (South), Kyrgyz Republic, Latvia, Lebanon, Lithuania, Luxembourg, Macao, China, Madagascar, Malta, Marshall Islands, Mauritius, Mexico, Monaco, Morocco, Netherlands, New Zealand, Nicaragua, Niger, Norway, Panama, Paraguay, Peru, Poland, Portugal, Romania, Singapore, Slovak Republic, Slovenia, Spain, St. Kitts and Nevis, St. Lucia, St. , St. Vincent and Grenadines, Suriname, Sweden, Switzerland, Syrian Arab Republic, Thailand, Trinidad and Tobago, Tunisia, Turkey, Uganda, United Kingdom, United States, Uruguay, Venezuela, West Bank and Gaza
Figure 1.1: Municipal Solid Waste Treatment Methods World-Wide & Sweden
(Hoornweg & Bhada-Tata 2012) The reason for a more sustainable waste treatment in Sweden is the high legislation standard. Landfills need to be set up in a controlled way, fees apply to landfill waste, it is forbidden to landfill organic waste and even higher fees apply if hazardous waste is landfilled. Bulky wastes are therefore avoided to be landfilled as it is firstly very cost intensive and secondly not sustainable as the number of landfills in Sweden are decreasing in the same time (Hansson 2013). A rather simple method on how to reduce the big waste volume, especially bulky waste, is incineration. As this process produces energy, it can be considered as sustainable. To assure a controlled incineration process without any harm to the environment the WtE plants need to have good flue gas cleaning systems. In addition safe treatment methods of the resulting ashes are required.
Dumps
19%
Landfills
52%
Compost
3%
Recycled
6%
WtE
4%
Other
16%
World-Wide*
Dumps
0%Landfills
5%
Compost
10%
Recycled
34%
WtE
50%
Other
1%
Sweden
2
One WtE plant in Sweden is owned and run by Renova AB, located in Sävenäs in Gothenburg: see chapter 4 for a detailed process description. In total there are 32 WtE plants in Sweden (Johansson, 2012), which have produced over 200 000 tonnes of fly ash in the year 2012 (Flyhammar 2013). 50% of the Swedish household and industrial waste is energetically processed for both electricity and district heating, which refers to 5 000 000 tonnes burning material per year (Avfall Sverige, 2012). Slag or bottom ashes from waste incineration can be used as additives in construction materials, whereas fly ash is classified as hazardous waste due to its high concentration of easily dissolved chlorides and heavy metals (Pettersson et al., 2013; Steenari & Zhao 2010). As a consequence it can only be landfilled or treated outside of Sweden (Pettersson et al. 2013; Avfall Sverige, 2012). Half of the annually produced Swedish fly ash is transported to Langøya in Norway or old German salt mines where it is treated and used as filling material (Pettersson et al., 2013). Renova stabilises the fly ash through the so called “Bamberg method”. The resulting product is a “Bamberg cake” which can be landfilled as non-hazardous waste (Renova AB 2013). Hereby, the fly ash is blended with thickened water treatment sludge by a portion of one weight part sludge to two weight parts ash. The outcome is a pasty product, which sets fast without any chemicals added. It is almost impermeable to water: if exposed to water only 5% results in leakage water (Thomé-Kozmiensky, 1994). Future Swedish legislations may however lead to the situation that this method no longer can be used. Henceforth, even though stabilised by the Bamberg method, the fly ash would still be classified as hazardous waste. Therefore new treatment methods need to be found in order to avoid high landfilling costs. One interesting component in fly ash is the heavy metal zinc. Pure zinc is applied in different industries. Even though a definite amount of virgin metal is indispensable, a certain demand could be satisfied by metal recovery from fly ash instead of developing new mines. Studies showed that the content of zinc in some fly ashes is comparable to the content in ores where new zinc mines are set up (Boliden Group 2013). As the zinc content in the fly ash from Renova is rather high, it is investigated if a recovery process through leaching and precipitation + filtration of zinc hydroxide is applicable. The zinc hydroxide product may then be sold directly to relevant companies or further upgraded to high purity zinc metal. This master thesis will take a deeper look into the overall process of the municipal solid waste incineration (MSWI) plant Renova AB. In form of a pilot plant, a possible applicable process is shown, on how to treat fly ash in order to minimize its toxicity and to recover zinc by using scrubber liquids. The pilot plant is 16 times smaller than if applied to the real life process at Renova.
2. Background
Acidic leaching of fly ash decreases the heavy metal part in this respect so that a back delivery into the furnace results in a transformation to bottom ash and therefore to non-
3
hazardous waste (Pettersson et al. 2013). A method, which is already applied in a plant in Switzerland. The results of all studies mentioned below are used as a basis for this pilot plant: its scale, construction and the variation of the experiments in the different campaigns. Additionally some experiments are made in the laboratory of Renova itself. One of the studies discussed how to wash fly ash from Renova with normal water in a multiple step process (Steenari & Zhao 2010). The fly ash was mixed with water and blended for a certain time. When filtrated, the filtrate liquid was stored and used to wash unwashed ash. The result of the study showed that chlorides could be washed out by washing the ash with normal water and reusing the wash water as first washing liquid. The fact that normal water can wash out chlorides is used during the leaching and the precipitation and filtration experiments (P&F) of the pilot plant. Another study, which knowledge is used, is the master thesis from Preiss, 2013. The thesis studied the behaviour of fly ash from Renova when mixed with HCl and, which blending is best to leach out zinc. The most important results from the thesis applied at the pilot plant leaching campaigns are:
pH value of 3,5 is ideal to leach zinc liquid to solid ratio (L/S) shall be over 3 best residence time for the fly ash HCl blending is 10 – 20 minutes zinc concentration decreases if the residence time is over 30 minutes pH value increases over time if no more acid is added
The study also suggests a two-step leaching process, which is not applied at the pilot plant as it is considered that a one step process will have enough zinc outcome and less costs. The study from Pettersson, and co-workers 2013 is the main study for this pilot plant project. A scenario is suggested in, which zinc is leached from fly ash using hydrochloric acid and where the ash residue from the leaching campaign is washed with water in order to reduce the chloride content. The residence time in the blending tank during the leaching process shall last less than 30 minutes and the L/S shall be 3. The separation of the ash residue from the zinc liquid filtrate shall be done by a vacuum belt filter. Separated from chlorides and other heavy metals, the ash residue might then be incinerated in order to destroy dioxins. The method of reincineration of the ash residue is already applied in a plant in Switzerland without any negative consequences (Schlumberger, Schuster, Ringmann & Koralewska 2007 & BSH Umweltservice AG 2013). The stored liquid from the leaching process shall be set into a neutralisation tank, in which the pH value shall be increased up to a level of 9.0 – 9.3. This can be done by blending the liquid with sodium hydroxide. By increasing the pH value, zinc hydroxide will precipitate and can then be separated from the liquid by using a chamber press filter. The economical conclusion of the study is that: by applying the described process, Renova could reduce its CO2 emission and reduce the process costs compared to the treatment that is used today in assumption that it is possible to sell the zinc product to other industries.
4
Another possibility to leach out zinc, is to use an alkali solution. However this also implies a lower leaching efficiency of zinc and the leaching of elements, which are not intended to be in the end product (Pettersson et al., 2013). This possibility is therefore not considered to be tested in the pilot plant.
3. Description of the Waste-to-Energy Process at Renova
The process at Renova AB is a standard process similar to any other WtE plant. Figure 3.1 is a simplified process illustration by means that it only shows the steps relevant for the pilot plant project. Waste is collected from the Gothenburg region by trucks and transported to the Renova WtE plant in Sävenäs. Here the waste is collected in a big waste bunker. A crane puts a certain amount of waste into the furnace of the boiler. While the waste material is burnt, no other fuel needs to be added. The energy is both used for electricity and district heating production. The bottom ash, consisting of fine particles up to larger metal scrap parts is transported to another plant of Renova located in Tagene where the material is sorted and recycled. The raw gas from the furnace is led into an electric filter where most of the solid particles are captured. This is the fly ash, which is used for the pilot plant experiments. The rest of the flue gas is led into different scrubbers for further cleaning steps. The first step is to wash the flue gas with normal water in order to release chlorides and by which hydrochloric acid is created. The following desulphurisation step is made by washing the remaining flue gas with sodium hydroxide solution (NaOH). It creates the sodium sulphate solution, which is used in the leaching campaign of the pilot plant experiments. A future process would be to use hydrogen peroxide (H2O2) instead of NaOH in the desulphurisation step where the outcome would be sulphuric acid instead of sodium sulphate solution.
The same NaOH solution, which is used for flue gas cleaning, is also used at the pilot plant throughout the precipitation and filtration campaign. Another outcome of the scrubbers is condensate water, which originates when the flue gas cools down and, which is also used throughout the pilot plant experiments.
5
Figure 3.1: Simplified WtE and Flue Gas cleaning process
Waste
Bottom Ash
Furnace
Hydrochloric Acid Sodium Sulphate Solution Condensate Water
Raw Gas E-Filter
Fly Ash
H2O wash
NaOH wash
Simplified WtE and Flue Gas Cleaning Process at Renova
Scrubbers
Waste-to-Energy
Flue Gas Cleaning
District
Heating
6
4. Material
All materials used during the pilot plant project are products or by-products created at the Renova WtE plant in Gothenburg. Some of the products such as fly ash are created during the incineration process whereas most of the liquids are produced during the flue gas cleaning process. See the previous chapter for more information. The element analysation of the material is based on a blending sample consisting of at least 4 single samples taken to different times throughout the experiments.
4.1 Fly Ash
Two types of ashes are created during waste incineration: bottom and fly ash. Whereas bottom ash also contains scrap metals, fly ash mostly consists of fine powder and larger black soot particles. Figure 4.1 shows that the colour of fly ash can vary between lighter and darker grey and sometimes even appear slightly yellow.
Figure 4.1: Fly ash from 2 different samples
The overall composition of fly ash from waste incineration plants is hard to predict as the different components of the fuel “waste” are changing continuously. Most of the elements in the fly ash are not existent in its pure form but in the form of oxides (Kalogirou et al., 2013). Figure 4.2 illustrates the average composition of the fly ash, which is used throughout the leaching experiments. The figure shows the most common elements in the fly ash in percent by weight in its pure form. The relatively high fraction “other” is mainly the weight of the oxide component oxygen. Calcium and chlorine has the biggest element fraction with 19wt% whereas zinc and magnesium only have a weight percent fraction of 2 and 1 respectively.
7
Figure 4.2: Average composition of the used fly ash in percent by weight
The fly ash samples for the leaching experiments are collected in so called “big bags”, which are commonly used for bulk powder storage and handling. Big bags are big plastic bags, which have a volume of around one cubic meter and are easy to cut from the bottom. The fly ash is collected at the “Bamberg blender”. Therefore the sludge flow into the blender is stopped so that only fly ash enters the blender. It is therefore possible to collect the fly ash at the place where usually the “Bamberg cake” is the outcome. The fly ash samples for analysation have been taken before the fly ash entered the blending tank of the ash leaching campaign. See chapter 5 and 7 for a detailed description of the pilot plant.
4.2 Scrubber liquids
4.2.1 Hydrochloric acid
The hydrochloric acid solution (HCl 3.5 wt%) is generated at the first flue gas cleaning scrubber when the incoming flue gas is washed with normal water. It has a transparent to light yellow appearance with small black particles. Figure 4.3 shows this appearance some weeks after the sample was taken and furthermore illustrates that around 4 % of the liquid consists of chlorides whereas the metal part is so low that it can be neglected.
Figure 4.3: HCl appearance and average composition in percent by weight
Cl
4 wt%
Metals
0 wt%
H2O +
Other
96 wt%
HCl
Cl
Metals
Cl
11%
S
5%
Zn
2%
Mg
1%
Al
3%
Ca
19%
Fe
2% K
5%
Na
6%Si
6%
Ti
1%
Other
39%
Average composition
of used Fly Ash in wt%
Cl S
Zn Mg
Al Ca
Fe K
Na Si
Ti Other
8
HCl has a very low pH value, which is around 0. Today at Renova it is neutralized with CaCO3 and Ca(OH)2, producing a CaCl2 solution, which is later in the process used for the production of gypsum.
4.2.2 Sodium sulphate solution
The Sodium sulphate solution (Na2SO4) is created during the desulphurisation cleaning step when the flue gas is washed with sodium hydroxide (NaOH). Figure 4.4 illustrates its composition. It is a transparent liquid, which has a low percent fraction of sodium (2%) and sulphate (1%).
Figure 4.4: Sodium Sulphate Solution average composition in percent by weight
After undergoing several cleaning steps the solution is nowadays mixed with the CaCl2 solution, producing gypsum. The gypsum is dewatered in a vacuum filter, similar to the pilot filter used in this project (Andersson 2016).
4.2.3 Condensate water
Condensate water is created when the flue gas in the condensing scrubber cools down, whilst energy is recovered and converted for the district heating process. It has the same properties as normal water although it has a slightly lower pH value and is warmed up to 60°C.
4.3 Other liquids
4.3.1 Sulphuric acid
The sulphuric acid solution (H2SO4) was bought special for this project. It is tested as a substitute for HCl. Future processes at Renova might lead to an internal production of this particular acid. The background idea is to use hydrogen peroxide (H2O2) instead of NaOH for the desulphurisation step (Andersson et al. 2013).
Cl
1 wt%Na
2 wt%
S
1 wt%
Ti
1 wt%
Other Metals
0 wt%
H2O + Other
95 wt%
Sodium
Sulphate
Solution
Cl
Na
S
Ti
9
4.3.2 Sodium Hydroxide
Sodium hydroxide (NaOH) is used at Renova in the internal waste water treatment. It is a 25wt% diluted, water based, transparent, solution, which is produced through chlorine-alkali-electrolysis and bought from external producers.
5. Pilot Plant Principle
The pilot plant set-up is based on results from previous studies and adjusted through conclusions made within the project. The campaigns can be divided into two parts: leaching and precipitation + filtration. Figure 5.1 illustrates the principle of the leaching process and shows pictures from the pilot plant leaching campaign. The fly ash is blended with hydrochloric acid or other scrubber liquids in order to leach out zinc. The residence time and pH value of the slurry is regulated to an intended value. The liquid is separated from the ash residue by the usage of a vacuum belt filter. The zinc filtrate liquid is stored in so called “cipax tanks” and the ash residue in big plastic containers.
a) Leaching Principle
Ash residue
10
b) Pilot Plant Leaching Campaign
Figure 5.1: a) Leaching Principle b) Pilot Plant Pictures of Leaching Process
The second step is to blend the stored zinc liquid with sodium hydroxide in order to achieve a precipitation of zinc hydroxide. The suspension is then filtered in a chamber press filter from, which the outcome is a “zinc cake” and filtration liquid. Figure 5.2 illustrates this principle and shows pictures from the pilot plant precipitation + filtration campaign (P&F).
a) Precipitation Principle
Big Bag with fly ash
on big bag cutter
Fly Ash is blended with
Scrubber Liquids. The
pH value of the Slurry
is pH regulated
Filtered Slurry (Ash
Residue) on vacuum
belt filter
Filtrate (Zinc Liquid)
from vacuum belt
filter stored in cipax
tank
Precipitation of Zinc Hydroxide when
NaOH is blended with Zinc Liquid
11
b) Pilot Plant P&F Campaign
Figure 5.2: a) Principle of Precipitation b) Pilot Plant Pictures of Precipitation Process
6. Laboratory experiments
Additional to the pilot plant, laboratory experiments are made in order to investigate the precipitation behaviour of zinc and magnesium in the zinc liquid. The experiments are done in the laboratory of the university in Borås.
6.1 Laboratory Set-up
Zinc liquids from the pilot plant leaching campaign are taken to Borås. Different pH values for the zinc hydroxide precipitation are set throughout several experiments. The zinc liquid is blended in a glass flask with the same NaOH solution that is used in the pilot plant P&F experiments (see chapter 8). After the intended pH value of the suspension is set and kept constant for at least 30 minutes, the suspension is filtered in a vacuum filter. The zinc hydroxide crystals fasten in the filter whereas the filtrate liquid passes the filter and is collected in the vacuum flask. Figure 6.1 illustrates the laboratory set-up.
NaOH is filled into
blending tank where it is
mixed with the Zinc Liquid
The pH value of the solution is
regulated so that Zinc Hydroxide
precipitates
Zinc Cake Product, from the filtered
suspension though the chamber press filter
12
Figure 6.1: Scheme of Laboratory Set-Up
Samples of the produced zinc cake are then analysed with a spectrometer in order to determine the zinc and magnesium content. Figure 6.2 shows the same set-up in real pictures of the used equipment.
Equipment from laboratory
Figure 6.2: Laboratory Equipment
Vacuum filter
Computer
stirring device
Laboratory Set-Up
Zinc cake
pH regulated
zinc liquid
Filtrate liquid
Suspension
pH electrode
b) pH-adjustment a) Filtration of Zn(OH)
a) pH-adjustment b) Filtration of Zn(OH)
13
6.2 Zn-Precipitation Method in Laboratory
The pH value of the zinc liquid is adjusted with different prefill methods in the same way as it is done in the pilot plant P&F campaign (see chapter 8). One prefill liquid is NaOH solution, the other one is zinc liquid itself. The different prefill methods are done as the morphology of the zinc hydroxide crystal formation is changing depending on, which prefill method is chosen (Top & Cetinkaya 2015). Different crystal formations may lead to a different product quality regarding different element contents in the product. The zinc cake product content is further investigated in this report whereas the morphology isn’t. The pH values for both prefill methods are adjusted to 7, 8, 9 and 10. The used zinc liquids are those from the leaching campaign C and D as those are the campaigns, which seem the most probable for a future big scale process at Renova (see chapter 7). 100 ml zinc liquid and as much NaOH solution as needed are mixed until the intended pH value is achieved. The stirring device is set to a slow blending rotation for 30 minutes before the suspension is filtered. The suspension is filled into the filter. It is done by filling in 25 ml at a time, pouring in more suspension before cracks in the zinc cake are formed. The filter time is measured until all the suspension is filled into the filter and the first cracks are formed. The filter time measurement indicates better or worse filtration. Table 6.1 shows the variations and filter time of the laboratory experiments.
Table 6.1: Overview over Laboratory variations
The filter cake and the filtrate is analysed by a spectrometer. The water content of the zinc cake is analysed by drying a sample in the oven over 2 days at a temperature of 100°C.
Experiment Zinc liquid pH NaOH prefill Time of filtration [min]
C1 C 10 x 03:30
C2 C 9 x 09:28
C3 C 8 x 05:15
C4 C 7 x 02:34
C5 C 7 - 01:33
C6 C 8 - 03:45
C7 C 9 - 06:28
C8 C 10 - 07:56
D1 D 10 x 08:41
D2 D 9 x 12:08
D3 D 8 x 15:08
D4 D 7 x 15:00
D5 D 7 - 16:43
D6 D 8 - 14:17
D7 D 9 - 16:43
D8 D 10 - 12:21
14
The zinc cake samples are prepared by dissolving a small amount in nitric acid, which is then diluted with distilled water. Table 6.2 shows the dilution.
Table 6.2: Overview over Laboratory sample preparation
After the liquid samples from the pipe have been taken, they are mixed with 250 ml of distilled water in a glass flask. A sample from the glass flask is then taken to analysation. For the filtrate: 0.4 ml filtrate sample is taken and mixed with 100 ml distilled water in a glass flask. It is then analysed with a spectrometer.
7. Pilot Plant: Leaching Campaign
Based on the results from previous studies a liquid to solid ratio of a minimum of 3 and a pH value of 3.5 is mainly studied throughout the leaching experiments (see chapter 2). A residence time, lower than 20 minutes is set in the blending tank.
7.1 Leaching Set-up
The regulation of the level in the tank and the pH value is stirred manually. The numbers shown in the tables below refer to the average value when the intended circumstances remain constant throughout at least 20 minutes and samples are taken. Figure 7.3 shows the set-up of the leaching process. The tank is first filled with scrubber liquid until a level of 60 litres. The big bag with fly ash is set onto the big bag cutter (also see figure 7.1). Two knives cut a hole into the bottom of the bag. The fly ash falls into transport screws, which move the fly ash into the blending tank. The ash flow is turned on once the liquid in the blending tank reaches the 60 litres mark. The blending device is turned on and
Zinc Cake
Experiment Total suspension
[ml]
sample
cake [g]
nitric acid
[ml]
dist. Water in
pipe [ml]
liquid sample from
pipe [ml]
C1 103 0,89 0,1 50 0,3
C2 102 1,46 0,2 50 0,3
C3 112 1,94 0,2 50 0,3
C4 111 1,36 0,2 50 0,5
C5 101 1,30 0,2 50 0,5
C6 102 1,20 0,2 50 0,3
C7 102 1,50 0,2 50 0,3
C8 103 1,62 0,2 50 0,3
D1 102 1,49 0,2 50 0,5
D2 108 0,93 0,2 50 0,5
D3 109 0,79 0,2 50 0,5
D4 106 1,13 0,2 50 0,5
D5 111 1,26 0,2 50 0,5
D6 111 1,26 0,2 50 0,5
D7 101 0,91 0,2 50 0,5
D8 102 1,16 0,2 50 0,5
15
both flows fill up the tank to an intended level (usually 90 – 110 litres; also see figure 7.2). The produced slurry in the blending tank is pH regulated (usually to around pH 3.5). The pH value is measured by a pH electrode, which is located at the inside of the tank. A pump transports the slurry from the blending tank to the vacuum belt filter once the intended slurry level is reached. The pump efficiency is set to a level so that the inflow stream is equal the outflow stream. The slurry from the tank reaches the vacuum belt filter from the top. The belt of the filter is moving from one end to another in several steps. Once the slurry reaches the belt, a vacuum from the bottom sucks away the zinc liquid filtrate. It is pumped into a cipax tank and stored for the P&F campaign. The ash residue on the belt filter is washed twice. First with the collected washing water from the second washing step and then with condensate water from the scrubber (see figure 7.3). Once the ash residue is transported to the end of the filter it is collected in a plastic container.
Figure 7.1: Big bag on big bag cutter Figure 7.2: Blending tank during leaching
Big Bag with
Fly Ash
Big Bag
cutter Fly Ash
Agglomeration
Fly Ash
Income pH-
electrode
Slurry
Blending
Device
Liquid
Income
16
Leaching Set-Up
Figure 7.3: Leaching Process Set-up
The blending device in the blending tank is a small propeller in the middle of the tank. As the propeller is only attached on the top of the tank a liquid level of a minimum of 60 litres is needed. A lower liquid level might cause a high vibration of the propeller, which may lead to a damage. The primary liquid fill up also minimizes the risk of agglomeration of fly ash in the tank, which otherwise could lead to a process stop or a damage of the propeller. A scale was manually written on the outside of the tank in order to control the liquid level in the tank. Throughout the experiments it happened that the agglomeration in the hoses from the blending tank to the filter is so high that a pump stop occurs. If that occurs the pump direction is changed every 5 seconds so that the back and forth movement of the liquid resolves the blockage in the hose. The pH electrode in the blending tank is calibrated every week. Depending on the set-up, the belt of the vacuum belt filter moves every 10 to 15 seconds. In total it has around 12 movement steps from when the slurry enters until the ash residue is collected. The filter is divided into different zones (also see figure 7.4). The first zone, which covers two movement steps, collects the zinc liquid filtrate from the slurry. The washing process of the ash residue covers around three movement steps. During the remaining movement steps the liquid in the ash residue is vacuumed, collected in a different zone from the filtrate and led to the drain.
Big Bag with
Fly Ash
Knives
Dosing Screws
Blending Tank
Income Scrubber
Liquids
Slurry
Vacuum Belt Filter
Zinc Liquid to Cipax
Ash
residue
Wash 2
Condensate Water
Wash 1
Recirculated
Wash Water
Filtrate from
Wash 2
Wash Water
to drain
17
Figure 7.4: Inside of the vacuum belt filer with ash residue and washing procedure
7.2 Leaching Method
Eleven different leaching variations are made in how the fly ash is blended with scrubber liquids in order to leach out zinc. The campaigns are called A to K. They are mainly focused on mixtures with fly ash and hydrochloric acid as this will most likely be applied at Renova AB in a big scale process. Table 7.1 gives an overview over the variations of the leaching campaign. The different colours in the table indicate the different scrubber liquids. All parameters for the blending are:
different scrubber liquids: Hydrochloric acid
Sodium sulphate solution
Condensate
Sulphuric acid
pH value, which was tried to be kept between 3 and 4 when acid liquids were used: pH 3.2 – 3.6
Liquid to solid ratio (L/S); indicates how much liquid is added to ash L/S 3 means that there is 1 part ash to 3 parts liquid:
L/S 3 – 6
residence time in the blending tank: Residence time 8 – 16 min
Ash residue
Condensate
wash
Recirculated
wash
Slurry
income
18
Campaign Hydrochloric
Acid
Sodium
Sulphate
Solution
Condensate Sulphuric
Acid pH L/S
Residence
time
[min]
A x - - - 3,6 3,1 13
B x - - - 3,6 3,3 8
C x - - - 3,3 3,5 10
G x - - - 3,3 3,6 11
H x - - - 3,2 4,4 16
J x - - - 3,4 3,3 13
D x x - - 3,5 6,2 8
F x x - - 3,6 5,5 9
I x - x - 3,5 5,8 9
K - - x x 3,6 3,9 10
E - - x - 10,2 3,9 9
Table 7.1: Overview of Leaching Variations
The leaching in campaign A, B, C, G, H and J is made with hydrochloric acid and fly ash only. An overview therefore can be seen in Table 7.2. The purpose of campaign A is to get to know the equipment and develop a feeling for the manual stirring by using the real material. An ash flow of 100 kg/h and a hydrochloric flow of 306 l/h is found in order to keep the pH value at 3.6 at a residence time of 11 minutes. In campaign B the maximum capacity of the vacuum belt filter is tested by using a higher ash and hydrochloric acid flow. The residence time hereby is kept rather low at 7 minutes. The campaigns C, G and J are set up like campaign A although ashes from different big bags are used. This is made to obtain more data and henceforth achieve more reliable results. Campaign H has the purpose to test a higher residence time.
Ash (kg/h) HCl [l/h]
Slurry on
filter [l/h] L/S
Level in
Tank [l]
Residence
time [min] pH
A 100 300 516 3,1 98 11 3,6
B 150 500 816 3,3 96 7 3,6
C 100 350 450 3,5 82 9 3,3
G 100 364 575 3,6 93 10 3,3
H 100 437 647 4,4 155 14 3,2
J 80 325 493 3,3 97 12 3,4
Table 7.2: Leaching Campaign with Hydrochloric Acid A, B, C, G, H, J
A higher residence time than in campaign H couldn’t be tested as the tank is designed for a maximum of 200 litres. A danger of over floating would therefore be present if a higher level than 160 litres was chosen as sudden stops in the pump from the tank to the filter can occur. Campaign D and F are set up with hydrochloric acid and sodium sulphate solution. This process set up might also find application in a big scale process. Nowadays the sodium sulphate solution is used for the production of gypsum together with hydrochloric acid. As
19
hydrochloric acid might be used for the leaching of zinc, a big part of the sodium sulphate solution might be overproduced. It is hence tested how the leaching efficiency of zinc from fly ash is affected if sodium sulphate solution is also brought into the process. Table 7.3 illustrates that the campaigns are set up in a rather similar way. The pH value is set to 3.5 and 3.6 with a residence time of 8 minutes in both experiments. The main variation is made within the liquid ratio. In campaign D a higher ratio of sodium sulphate solution is used whereas campaign F has a higher ratio of hydrochloric acid.
Ash
(kg/h)
HCl
[l/h]
Sodium
Sulphate
Solution [l/h]
Slurry
on filter
[l/h]
L/S Level in
Tank [l]
Residence
time
[min]
pH
D 75 211 250 619 6,2 81 8 3,5
F 100 356 194 760 5,5 106 8 3,6
Table 7.3: Leaching Campaign with Hydrochloric Acid and Sodium Sulphate Solution D, F
After evaluating the first results it is considered that a high L/S ratio is profitable for a high zinc leaching efficiency and a good process stirring. Campaign I investigates if it is really due to the higher L/S ratio and not due to the sodium sulphate solution. A blending as in campaign D is therefore set up by using condensate water instead of sodium sulphate solution. The pH value is kept at 3.5 and the residence time at 9 minutes (table 7.4).
Ash
(kg/h)
HCl
[l/h]
Condensate
[l/h]
Slurry
on filter
[l/h] L/S
Level in
Tank [l]
Residence
time [min] pH
I 75 216 223 596 5,8 86 9 3,5
Table 7.4: Leaching Campaign with Hydrochloric Acid and Condensate I
As already mentioned, a future process at Renova could lead to a production of sulphuric acid. It is therefore tested in campaign K if sulphuric acid can replace hydrochloric acid in the zinc leaching campaign. The used sulphuric acid solution has a higher concentration as the hydrochloric acid solution from the scrubber and is therefore blended with condensate water. The L/S ratio, residence time and pH value is approximately the same as when hydrochloric acid is used. Table 7.5 illustrates the data of campaign K.
Ash
(kg/h)
Condensate
[l/h]
Sulphuric
acid (l/h)
Slurry
on filter
[l/h] L/S
Level in
Tank [l]
Residence
time
[min] pH
K 100 320 71 601 3,9 93 9 3,6
Table 7.5: Leaching Campaign with Sulphuric Acid and Condensate K
As it is the last experiment of the leaching campaign the pump has stopped frequently due to high agglomeration in the hoses. It is therefore important for the big scale process that frequent maintenance is applied.
20
Campaign E is made in order to evaluate the chloride washout in the fly ash. Therefore ash is blended with condensate water only. As the pH value is far too high (pH 10.2) to leach out zinc it is not expected to obtain a good zinc liquid filtrate. Table 7.6 shows the details of campaign E.
Ash
(kg/h)
Condensate
[l/h]
Slurry on
filter [l/h] L/S
Level in
Tank [l]
Residence
time [min] pH
E 125 490 753 3,9 97 8 10,2
Table 7.6: Leaching Campaign with Condensate E
The calculations of the different values in the tables can be found in Appendix 1. During the campaign experiments itself, the numbers were estimated in a simpler way so that faster adjustments of the settings could be made. The ash residue is delivered back into the furnace after being washed on the vacuum belt filter. In theory the chlorides are washed out (Steenari & Zhao 2010), dioxins get destroyed through re-incineration and instead of recreating fly ash the ash residue will terminate as bottom ash (Vehlow et al, 1991). Results and further description of the back delivery of the ash residue into the furnace isn’t discussed in this thesis but in the final report of the “Energiforsk” project: Hållbar behandling av avfallsflygaska genom lakning, termisk
behandling och zinkåtervinning.
8. Pilot Plant: Precipitation and Filtration Campaign
The precipitation of zinc hydroxide from the previously stored zinc liquid shall be achieved by regulating the pH value of the liquid to 9.25 (EPA 1980). As figure 8.1 shows, this is the value where the solubility of zinc hydroxide is the lowest and therefore the precipitation the highest.
Figure 8.1: Precipitation of Heavy Metal Hydroxides
(EPA 1980)
21
Figure 8.2 underlines why a pH of 9.25 is chosen. It shows that the preciptiation of zinc can also be achieved at higher pH values towards pH 10. Though is also the precipitation of cadmium, nickel and lead higher towards this value. As the precipitation and filtration campaign concentrates on the precipitation of zinc, the pH value is chosen, which lays below a high precipitation rate of these elements: 9.25.
Figure 8.2: Precipitaion of Zinc and other metals
(Hoffland Env. 2012)
Further investigation of the precipitation behaviour with the used material were made in the laboratory of the University of Borås (see the results in chapter 9.1).
8.1 Precipitation and Filtration Set-up
The same blending tank and pH electrode as in the leaching experiments are used for the P&F experiments. Both are cleaned before the start of the experiments and the pH electrode is newly calibrated. The regulation of the pH value in the blending tank is stirred manually in the same way as it was done throughout the leaching experiments. Figure 8.3 illustrates the set-up of the precipitation and filtration experiment. The zinc liquid is filled into the blending tank to a level of approximately 190 litres. The pH value is regulated to the intended value by using a 25wt% sodium hydroxide solution. The suspension is pumped into the chamber press filter. The zinc hydroxide crystals agglomerate in the chambers of the filter, forming the end product, the zinc cake. The filtrate liquid is pressed out, collected and its flow rate and volume measured. Around 100 litres of suspension is pumped into the filter before the suspension flow is turned off. The amount of 100 litres is chosen to assure enough production of zinc cake. Once the suspension flow is turned off, the wash water is pumped into the chamber press filter and pressed through the zinc cake in order to wash out chlorides. The rest of the filtrate liquid is pressed out by using both mechanical
22
pressure and pressurised air. The out coming wash water filtrate is pumped to the drain. The chamber press filter is then opened and the zinc cake collected.
Precipitation and Filtration Set-Up
Figure 8.3 Set-up of Precipitation and Filtration Process
The calibration of the pH electrode is done regularly. The formation of zinc hydroxide crystals is ensured by setting the blending device to a low mixing rate for a certain time (minimum 30 minutes). The suspension is pumped from the blending tank into the chamber press filter through a hose, which is put from the top opening of the blending tank, reaching down to the tank bottom. The flow rate of the suspension into the chamber press filter is stirred by manual pump regulation with no direct flow rate measurement. If more than 100 litres of suspension are pumped into the filter, the zinc hydroxide crystals don’t agglomerate anymore as the capacity of the filter is exceeded. Instead, the suspension instantly exits the filter.
8.2 Precipitation and Filtration Method
Different parameters are set throughout the P&F experiments. After the first results of the experiments are evaluated further variations are made based on this data. The parameters of the P&F experiments are:
Zinc Liquid
Different zinc liquids originating from the different leaching campaigns are tested. In order to know, which zinc liquid is used, the P&F campaigns are marked with the
NaOH 25%
Zinc Liquid
Blending Tank
Suspension
Wash Water
1. Filtrate to internal
water cleaning
2. Wash Water Filtrate
to drain
Zinc Cake
Chamber Press Filter
23
same letter as used in the leaching campaign (A-K; e.g. FA refers to the zinc liquid from the leaching campaign A).
Warmed Zinc Liquid
The zinc liquid is warmed to approximately 40°C directly in the cipax tank. A hose with warm condensate water is therefore put into the cipax. The condensate water is not mixed with the zinc liquid but led through a hose into the drain. Figure 8.4 illustrates this warming process.
Figure 8.4: Warming procedure of Zinc Liquid in Cipax tank
Flotation
The purpose of flotation is to mix the liquid in the cipax tank. The fine solid particles (fly ash that follows the zinc liquid filtrate at the leaching campaign), which have sunken to the bottom during the storing time are bloated back into the liquid. Therefore pressurised air is led into the cipax by a hose and an attached staff at its end. Figure 8.5 illustrates this procedure.
Figure 8.5: Flotation procedure of Zinc Liquid in Cipax Tank
Cipax with Zinc Liquid
Warm
Condensate
Condensate
to drain
Pressurised Air
Cipax with Zinc Liquid
24
Prefill of Zinc Liquid or Sodium Hydroxide Solution
The regulation of the pH value is done by two variations. The first one is to fill up the blending tank with zinc liquid and then adjust the pH value by adding sodium hydroxide. The other variation is to prefill the tank with the sodium hydroxide solution and then regulate the pH value by adding the zinc liquid. The difference between those variations may affect the formation behaviour of the zinc hydroxide crystals. If the zinc liquid is prefilled, the crystals experience an alkali environment around pH 6. At the variation where the sodium hydroxide solution is prefilled the crystals experience a high pH value environment of around pH 12 before the value is lowered to the intended pH 9.25. Different elements can therefore be built into the crystal structure, which may lead to a changed zinc cake composition (Separation Science and Technology, 2009).
pH Value
The variation of the pH value may as well affect the composition of the zinc cake. Depending on its value other components (e.g. magnesium) of the zinc liquid also precipitate more or less (Materials science forum, 2014). A variation is therefore made in order to find the perfect zinc cake composition.
Blending Time
The blending time affects the formation of the zinc hydroxide crystals. In total all experiments are blended for at least 30 minutes. Some of them even have a blending time of more than one hour.
Precoating
Precoating means that a bit of ash residue from the leaching campaign is blended into the regulated pH suspension. The idea is that the zinc cake gets more porous and is therefore better to wash as the occurrence of big cracks minimizes.
Flocculent
A flocculent shall bind the formed crystals more together in order to ease the filtration. However the experiments showed that the addition of the flocculent (Magnafloc) had no effect, which leads to the decision to use no flocculent at the P&F experiments. Therefore the flocculent is only added in the first experiments.
Amount of suspension into filter
The amount of suspension into the filter is tried to be kept at 100 litre. The same suspension volume ensures an accurate comparison of the zinc cake product. Nevertheless the out coming filtrate water is sometimes getting turbid before the 100 litre mark is reached. Turbid filtrate liquid indicates an existing highly sealed zinc cake in the filter. As consequence no more suspension can be filtrated. If that occurs the input of suspension into the filter is stopped.
25
Zinc cake build up time
A pump regulates the flow rate of the suspension into the filter and therefore the rapidness of the cake build up (~10-30 min). A slower cake build up might lead to a better washing rate and therefore a better product.
Type of wash water
Two different wash waters are used: normal tab water and warm condensate water from the scrubber (~40°C). Both liquids might get used at a big scale process.
Amount of wash water and time of washing
Different wash settings may lead to different properties of the zinc cake product (e.g. chloride content). A lower flowrate might minimize big cracks in the zinc cake and therefore avoid a one-sided washing.
Washing method
Two different wash settings are available at the used chamber press filter. One way is to wash the cake in the filter from the centre to the outside. The other method is to do a cross wash where the wash water enters the cake from each corner. A variation of these washing methods is done by either using only the centre wash or applying both methods. If both methods are applied it is firstly washed from the centre and then changed to the cross wash (half cross wash).
Repulp
The repulp campaign is tested in order to reduce the chloride content in the zinc cake product. A zinc cake product is put into a big bucket and blended with water. This mix is manually blended for around 20 minutes. The suspension is then pumped into the filter and filtrated again.
Table 8.1 shows the parameters for each P&F campaign. The different colours imply, which zinc liquid was used. Grey stands for zinc liquid that was produced by only using hydrochloric acid, green for hydrochloric acid + sodium sulphate solution, blue for hydrochloric acid + condensate water and yellow for sulfuric acid + condensate water. For the repulp campaign, the cake from campaign F11D is used and is therefore also marked as green.
26
Washing
Campaign Warmed Flotation
Zinc
Liquid
prefill
NaOH
prefill Precoating pH Flocculent
1h
blending
Suspension
[l] Water
Condensate
water
Cake build
up [min]
Cake
Washing
[min]
Cake
build up
[l]
Cake
Washing
[l]
half
cross
wash
F1B x - x - - 9,0 x - 100 - x 30 12 90 80 -
F2B x - x - - 9,0 x - 90 - x 21 14 80 30 -
F3A x - x - - 9,1 x - 85 - x 12 8 60 50 -
F4A* x - x - - 9,2 x - 60 - x 16 5 60 40 -
F5A x x x - - 10,5 x - 72 - x 10 8 70 50 -
F6C x x x - - 9,0 - - 98 - x 9 8 90 80 -
F7C* x x x - - 9,2 - - 98 x - 14 24 110 80 x
F12C x x - x x 10,5 - x 87 x - 26 18 70 110 -
F13C* x x - x x 8,1 - x 95 x - 22 20 80 110 -
F11D - - x - - 9,1 x - 110 x - 13 0 130 0 -
F14D x x - x - 9,3 - x 90 x - 17 24 80 110 -
F15D* x x - x x 9,3 - x 75 x - 22 23 80 110 -
F16D x x - x - 6,9 - x 82 x - 22 36 70 110 -
F17D* x x - x - 7,9 - x 83 x - 19 35 80 120 -
F10I - - x - - 9,3 - - 120 x - 9 6 110 70 x
F8K x - x - - 9,0 - - 98 x - 12 10 90 70 x
F9K* x - x - - 9,0 - - 79 x - 10 12 80 70 x
F18K x x - x - 9,6 - x 85 x - 36 37 70 110 -
F19K* x x - x - 7,8 - x 99 x - 37 37 90 110 -
Repulp** - - - - - 8,5 - - 95 x - - - 80 0 -
*Mixture is based on suspension of previous campaign e.g.: F3A was the base for the suspension of F4A **Zinc cake from campaign F11D was used
Table 8.1: Overview of Precipitation and Filtration variations
27
9. Results and Discussion
All results and conclusions are funded on: the samples from the pilot plant, which are analysed by an external laboratory, the experiments in the laboratory in the University of Borås and the conclusions during the pilot plant process. The samples from the pilot plant experiments are aggregate samples. They consists of single samples, which are collected to different times of the experiments and then mixed together before sent in to the external laboratory. These aggregate samples consist of a minimum of four different single samples. The purpose of this procedure is to prevent single outrages. The rule of thumb is: the more single samples form the aggregate sample, the more realistic are the results.
9.1 Pilot Plant Leaching
The average zinc leaching efficiency of all leaching experiments is 60% (figure 9.3). It refers to the zinc content in the fly ash and the zinc concentration in the zinc liquid. The average of 60% doesn’t include the results from campaign E as the leaching of zinc is not its main priority. However, all results are shown in figure 9.3, including campaign E. The best leaching result of 74% is achieved in campaign D where the fly as is mixed with HCl and sodium sulphate solution. 47% is the lowest leaching result except from E (25%) and occurred at campaign I where HCl was mixed with condensate water. Campaign B, G, H and K have leaching results above average whereas A, C, J and F show lower results. As predicted E has a much lower leaching result with only 25 %.
Figure 9.3: Leaching result of Zinc from Fly Ash
The pH value is kept between 3.2 and 3.7. As figure 9.4 illustrates, all tested pH values led to a zinc leaching efficiency over 45%. The best pH value from previous laboratory investigation is at 3.5 (Pettersson et al., 2013). However, in the pilot plant the best and the worst leaching efficiency was achieved at this value. The results don’t show if different pH values shall be applied to different liquid blends. It can be assumed that the blending with HCl and condensate water leads to the worst leaching of zinc (campaign I 45%). However as this blending was only tested once the result can also be an individual case. Future studies in
0%
20%
40%
60%
80%
100%
D H K G B C F A J I E
Leaching: Zinc
Linear (Total) Linear (Average)
*
*not included in the average calculation
28
this field might be of interest. In total it can be said that all pH settings showed a satisfying zinc leaching efficiency.
Figure 9.4: Zinc leaching efficiency over pH
A valuable end product has a high purity of zinc. In order to obtain a high purity product, a leaching efficiency is preferred that gives a low concentration of other metals. Figure 9.5 compares the leaching efficiency of zinc and magnesium. The magnesium content is of importance as relevant customers demand a low content (Boliden: 2735 mg/kg Zinc). Relevant customers are companies, to, which it might be able to sell the zinc product. It can be said that if the leaching efficiency of zinc is higher, the leaching efficiency of magnesium is higher as well. The linear line for both metals shows that the magnesium leaching efficiency at higher pH values seems to minimize whereas the leaching efficiency of zinc keeps rather constant. For the big scale process a higher pH value of the tested range (pH 3.7) is therefore recommended.
Figure 9.5: Leaching efficiency of Zinc and Magnesium over pH
Previous laboratory studies showed that the best leaching efficiency of zinc was achieved at a pH value of 4.2 (Preiss 2013). It might therefore even be possible to set the future leaching process to 4.2. As the pH value of 4.2 wasn’t tested throughout the leaching experiment it cannot be confirmed that the high zinc leaching efficiency also applies to a big scale process. A higher pH value blending will be positive as less acid solution is necessary to achieve this value.
0%
20%
40%
60%
80%
100%
3,2 3,3 3,4 3,5 3,6 3,7 pH
Leaching efficiency:
pH
Leaching rate Zinc
Leaching rate Magnesium
Linear (Leaching rate Zinc)
Linear (Leaching rate
Magnesium)
0%
20%
40%
60%
80%
100%
3,2 3,3 3,4 3,5 3,6 3,7 pH
Zinc leaching:
pH
HCl
HCl + SSS
HCl + Cond.
SulA. + Cond.
29
Whereas continuous adjustments of the different flows are necessary at lower L/S rates in order to keep the pH value of the mixture stable, a higher L/S rate: over 5, facilitates the manual regulation of the process. However this problem will not apply to the big scale process as all regulations will be done automatically. As figure 9.6 shows, the leaching efficiency at L/S 4 is lower than the leaching efficiency towards L/S 5. Higher L/S blends didn’t influence the leaching efficiency in a positive way. This behaviour has also been found in previous studies: “the L/S ratio … played a minor role for the leaching effect as long as it was high enough to ensure a good blending.” (Pettersson et al., 2013). Therefore an L/S ratio of 4 to 5 should be sufficient for a big scale process.
Figure 9.6: Zinc leaching efficiency over L/S
The residence time doesn’t play a major role for the zinc leaching efficiency (figure 9.7). Figure 9.7 shows that the best result is achieved at 9 minutes. One campaign was set to a residence time of 16 minutes but didn’t achieve a greater leaching efficiency.
Figure 9.7: Zinc leaching efficiency over Residence time
The best process set ups are short in time and with a minimal amount of process steps. A low residence time, at 10 minutes can therefore be chosen for a big scale process. It is highly recommended to perform a frequent maintenance of the process equipment to ensure a smooth process flow. Otherwise agglomeration may lead to a process stop, which
0%
20%
40%
60%
80%
100%
2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0 6,5L/S
Zinc leaching:
L/S
HCl
HCl + SSS
HCl + Cond.
SulA. + Cond.
0%
20%
40%
60%
80%
100%
7 9 11 13 15 17min
Zinc leaching:
Residence time [min]
HCl
HCl + SSS
HCl + Cond.
SulA. + Cond.
30
was also discovered in one of the previous studies (Steenari & Zhao 2010). As different scrubber liquids were mixed throughout the pilot plant leaching experiments, an agglomeration of gypsum and ash occurred in the blending tank, the vacuum belt filter and the hoses from the blending tank to the filter. These agglomerations made the regulation of the process more difficult towards the last experiments. One maintenance method to minimize these agglomerations might be to rinse the devices with one of the scrubber acids or to clean the equipment manually with a brush and change the hoses frequently. The zinc liquids A, B, C, D, I and K are chosen for the precipitation and filtration campaign. A, B and C are gained from a leaching with hydrochloric acid only. They are most investigated as a leaching with hydrochloric acid is the set-up, which will most likely become realistic in a big scale process. D (hydrochloric acid + sodium sulphate solution) and I (hydrochloric acid + condensate water) are chosen in order to investigate in zinc liquids, which have been leached by adding other scrubber liquids as this might also be applied in a big scale process. K (sulphuric acid + condensate water) is tested as it might become interesting for Renova for a future process in, which sulphuric acid is produced as scrubber liquid. 9.2 Laboratory Precipitation and Filtration
The laboratory experiments are evaluated by analysing two probes from all samples and using the average value. The P&F efficiency is evaluated by comparing the zinc content in the zinc liquid filtrate and the zinc content in the zinc cake. The experiments in the laboratory show much lower zinc P&F efficiencies than compared to the results from the experiments in the pilot plant. Whereas the pilot plant shows an average zinc P&F efficiency of 82% (see chapter 9.3), the average zinc P&F efficiency in the laboratory is at 15% (Table 9.1). The maximum zinc P&F efficiency of 32% is achieved in experiment D1 with a pH value of 10 and where sodium hydroxide is prefilled. On the other hand the same set up with the zinc liquid of campaign C achieves the lowest zinc P&F efficiency with only 4%. A good zinc cake product has a high zinc and a low magnesium content, therefore the P&F efficiency for magnesium is subtracted from the zinc P&F efficiency. The highest percentage of this subtraction shows the best P&F rate towards a high quality product. It is achieved at pH values around 7 and 8. The figures 9.1, 9.2 and table 9.1 illustrate the results of the laboratory.
Experiment pH NaOH first Rate Zn % Rate Mg % Difference Zn - Mg
C1 10 x 4% 4% 0%
C2 9 x 11% 8% 3%
C3 8 x 17% 11% 6%
C4 7 x 20% 1% 19%
C5 7 - 15% 1% 14%
C6 8 - 7% 1% 6%
C7 9 - 10% 2% 7%
C8 10 - 17% 16% 1%
D1 10 x 32% 29% 3%
D2 9 x 14% 7% 6%
31
D3 8 x 9% 1% 8%
D4 7 x 15% 1% 14%
D5 7 - 19% 1% 18%
D6 8 - 21% 1% 20%
D7 9 - 8% 0% 7%
D8 10 - 21% 16% 5%
Average 15% 6%
Table 9.1: Laboratory results: zinc and magnesium precipitation
Figure 9.1: Zinc precipitation and filtration rate in laboratory
Figure 9.2: Magnesium precipitation and filtration rate in laboratory
A reason for why the laboratory P&F experiments showed a much lower P&F efficiency compared to the pilot plant P&F experiments, could be an inaccurate sample taking. As mentioned before, the zinc and magnesium content in the zinc liquid and the final zinc cake product content is compared to evaluate the P&F efficiency. The samples from the zinc liquid have been taken when the leaching campaign was performed. The hose, which led from the vacuum belt filter to the cipax tank was therefore taken out of the cipax and the zinc liquid filtrate was filled into sample containers. However the zinc liquid filtrate for the laboratory experiments has been taken after the leaching experiments were already finished and the zinc liquid already has been stored several months. The samples have been taken through a small opening at the top of the cipax tank. Even though manual stirring with a stick has been done before the samples have been taken, it may have occurred that some zinc hydroxide crystals have already been precipitated, sunken to the bottom and couldn’t be floated back into the
0
2000
4000
6000
8000
10000
6,9 7,4 7,9 8,4 8,9 9,4 9,9
Co
nce
ntr
ati
on
mg
/kg
pH
Laboratory: Zinc
P&F efficiency
C: Zn NaOH prefill
C: Zn zinc liquid prefill
D: Zn NaOH prefill
D: Zn zinc liquid prefill
0
100
200
300
400
6,9 7,4 7,9 8,4 8,9 9,4 9,9
Co
nce
tra
tio
n m
g/k
g
pH
Laboratory:
Magnesium
P&F efficiency
C: Mg NaOH prefill
C: Mg zinc liquid prefill
D: Mg NaOH prefill
D: Mg zinc liquid prefill
32
liquid. A reason for this early precipitation might be that the pH value of the zinc liquid increased from pH 3 to pH 6 during the storing time of 2 months due to fine ash particles in the liquid.
9.3 Pilot Plant: Precipitation and Filtration
In order to find out, which set-up lead to the best result, the zinc concentration in the zinc liquid is compared to the correspondent zinc content in the zinc cake. Hence, it shall be studied how much of the available zinc in the zinc liquid could be precipitated in the final product. A maximum P&F rate of 100% is possible. The results show an average rate of 82% and a maximum of 109% (figure 9.8). A maximum of 109% is theoretically not possible and probably comes from measurement inaccuracies, which can be up to 25% for the measurement of zinc. It shows the importance of more investigation and experiments. Figure 9.8 shows all the results. The repulp campaign is not included in the evaluation of the average rate as it is a 2 step process and henceforth different from the other precipitation and filtration experiments. F2B, F12C, F11D and F10I have the best results with a range from 109% to 97% whereas F3A, F14D, F8K and F18K show the lowest but still good rates between 64% and 70%.
Figure 9.8: Precipitation and Filtration rate: Zinc
It is mentioned in chapter 8 that the precipitation of zinc is best obtained at a pH value of 9.2. Figure 9.9 shows that most of the campaigns are set to this value. Other pH values are tested at a range from 7 to 10.5 in order to investigate if the product quality changes in a positive way (e.g. lower magnesium content). The evaluation of the product quality is briefly done in chapter 9.4 and further discussed in the final report: Hållbar behandling av avfallsflygaska
genom lakning, termisk behandling och zinkåtervinning (Energiforsk)
0%
20%
40%
60%
80%
100%
P&F rate: Zinc
Linear (Total) Linear (Average)
*
*not included in the average calculation
33
Figure 9.9: Zinc Precipitation and Filtration rate over pH
The precipitation of zinc is possible at all investigated pH values, which means that a minimum of 64% of zinc could be precipitated and filtrated from the former zinc liquid. Based on the results from the pilot plant, it cannot be said that there is a particular pH value, which can be prioritised by just focusing on the zinc P&F efficiency. A low pH value is beneficial for a future big scale process as it implies less NaOH usage and therefore less costs. The results from the laboratory experiments also showed that a low pH might be beneficial in order to obtain a low magnesium content (chapter 9.1). The results of the two prefill variations are illustrated in figure 9.10. The experiments F1B to F11D are done by a prefill of zinc liquid whereas the other experiments with higher numbers are done by a prefill of sodium hydroxide.
Figure 9.10: Zinc Precipitation and Filtration over pH + prefill
In order to evaluate, which prefill method is preferable, an investigation of the product quality (chapter 9.4 + final report) and future studies in the crystal formation are necessary.
50%
60%
70%
80%
90%
100%
110%
6,8 7,1 7,4 7,7 8,0 8,3 8,6 8,9 9,2 9,5 9,8 10,1 10,4 10,7pH
Zinc
P&F: pH
HCl
HCl + SSS
HCl + Cond.
SulA. + Cond.
50%
60%
70%
80%
90%
100%
110%
6,8 7,1 7,4 7,7 8,0 8,3 8,6 8,9 9,2 9,5 9,8 10,1 10,4 10,7 pH
Zinc P&F:
pH + prefill
Zinc Liquid
prefill
NaOH prefill
34
Figure 9.11 shows that no effect on the zinc P&F could be observed when a flocculent is used. It is therefore not recommended to use a flocculent for a big scale process.
Figure 9.11: Zinc Precipitation and Filtration over Flocculent
A slight influence of the zinc cake formation time and zinc cake washing time is shown in figure 9.12 and 9.13. The trend goes towards that as longer both processes take, the lower is the recovery of zinc. Although it isn’t of great difference in both cases, future studies can investigate if longer times lead to a lower chloride content and therefore a higher quality of the zinc cake product.
Figure 9.12: Zinc Precipitation and Filtration over zinc cake formation time
Figure 9.13: Zinc Precipitation and Filtration over zinc cake wash time
50%
60%
70%
80%
90%
100%
110%
6,8 7,1 7,4 7,7 8,0 8,3 8,6 8,9 9,2 9,5 9,8 10,1 10,4 10,7 pH
Zinc P&F:
Flocculent
With Flocculent
Without Flocculent
50%
60%
70%
80%
90%
100%
110%
0 5 10 15 20 25 30 35 40min
Zinc P&F:
Zinc cake
wash time
HCl
HCl + SSS
HCl + Cond.
SulA. + Cond.
50%
60%
70%
80%
90%
100%
110%
0 5 10 15 20 25 30 35 40min
Zinc P&F:
Zinc cake
formation time
HCl
HCl + SSS
HCl + Cond.
SulA. + Cond.
35
9.4 Total zinc recovery from the pilot plant
Figure 9.14 illustrates the total zinc recovery from the fly ash to the zinc cake end product. Therefore the zinc content in the fly ash is compared to the zinc content in the final zinc cake. The best results are achieved in the campaigns F11D (72%), F10I (67%) and F12C (62%). The average is at 53%; the minimum at 41% (F18K).
Figure 9.14: Total zinc recovery from fly ash to zinc cake
Campaign I shows that a high zinc recovery (67%) could be obtained even though the zinc leaching efficiency was low (47%). Table 9.2 shows the total recovery of zinc in gram from 10 kg of fly ash and the zinc content in 10 kg virgin fly ash.
Table 9.2: Zinc win from 10 kg virgin fly ash
Zinc win [g] from
10 kg fly ash
Zinc [g] in 10 kg
resp. Fly Ash
F1B 122 248
F2B 151 248
F3A 108 248
F4A 151 248
F5A 125 248
F6C 130 258
F7C 142 258
F12C 159 258
F13C 144 258
F11D 199 277
Zinc win [g] from
10 kg fly ash
Zinc [g] in 10 kg
resp. Fly Ash
F14D 131 277
F15D 150 277
F16D 153 277
F17D 156 277
F10I 145 218
F8K 118 278
F9K 129 278
F18K 114 278
F19K 130 278
Repulp 63 277
0%
20%
40%
60%
80%
100%
Total Zinc recovery from Fly Ash to Zinc Cake
Linear (Total) Linear (Average)
*
*not included in the average calculation
36
The evaluation of the best method cannot be done by only looking at the zinc recovery efficiency. An evaluation of the best methods is therefore done in the next chapter by including the product quality. 9.5 Zinc cake end product from the pilot plant
In average the zinc cake end product has a content as shown in figure 9.15 and figure 9.16. The data in figure 9.15 refers to a zinc cake, which is freshly extracted from the chamber press filter whereas figure 9.16 shows the composition of the dry product. The part “non-metals” in both figures mainly consists of oxygen and hydrogen as the main compounds are hydroxides.
Figure 9.15: Average composition of the wet zinc cake end product
Figure 9.16: Average composition of the dry zinc cake end product
The quality of the zinc cake end product is evaluated in table 9.3. It shows the element percentage of a dry product. The perfect end product has a high zinc content and a low amount of other contents. A factor for the best product is developed in, which the content of Mg and Cl is subtracted from the content of zinc. The higher the value of the best product is, the better the zinc cake product in aspect of low Mg- and Cl-content. The green colour indicates a good, whereas the red colour indicates a less good product quality.
Zn
9% Cl
3%
Mg
1%
Other
7%
Moisture
80%
Average
Zinc Cake composition
wet product
wt% Zn
Cl
Mg
non metals
Moisture
Zn
45%
Cl
16%
Mg
5%
Other
34%
Average
Zinc Cake composition
dry product
wt%
Zn
Cl
Mg
non metals
37
Factor for best product Zn Mg Cl Other metals Non metals
F16D 49% 50% 0% 1% 14% 35%
Repulp 45% 52% 4% 3% 7% 34%
F6C 41% 48% 4% 3% 5% 40%
F15D 35% 45% 5% 5% 14% 32%
F17D 32% 46% 1% 13% 13% 28%
F18K 32% 44% 1% 11% 16% 28%
F19K 32% 42% 0% 10% 14% 33%
F7C 28% 42% 5% 9% 9% 35%
F3A 27% 42% 7% 8% 7% 36%
F11D 23% 34% 4% 8% 11% 44%
F9K 21% 36% 7% 8% 11% 38%
F10I 21% 38% 7% 10% 9% 36%
F14D 18% 40% 5% 17% 13% 25%
F8K 15% 32% 7% 10% 14% 38%
F5A 9% 30% 9% 12% 15% 34%
F2B 6% 31% 5% 21% 15% 29%
F1B 4% 32% 5% 24% 15% 24%
F4A 0% 26% 5% 21% 15% 33%
F13C -3% 38% 6% 35% 20% 1%
F12C -7% 37% 7% 37% 17% 2%
Table 9.3: Composition of dry zinc cake end product per campaign
Generally the trend indicates that products with higher quality have been gained through a leaching with hydrochloric acid + sodium sulphate solution (FD). All products with low quality originate from a leaching with hydrochloric acid only (FA, FB). Although FC is also a hydrochloric acid leachate, it shows one of the best and the worst product qualities. All products from zinc liquid C (F6C, F7C, F13C and F12C) show a good zinc content (minimum 37%). However the high amount of chlorides in campaign F13C (Cl 35%) and F12C (Cl 37%), minimizes the product quality affectedly. A reason might be that the precoating method was applied in both campaigns (table 9.4). As mentioned before the precoating method implies a higher concentration of ash residue in the final zinc product (see chapter 8.2), which should improve the chloride washout. But, as the ash residue itself contains chlorides, a chloride embedding into the crystal structure during the zinc hydroxide precipitation is possible, which prevented a chloride washout. If the embedding of chlorides into the structure can be proved by future studies, the zinc cake washing will be irrelevant as it even minimizes the zinc content in the final product (figure 9.13). On the other hand a higher washing rate applied to zinc products with a higher quality (table 9.4). A combination of both theories might therefore be accurate: some chlorides embed in the crystal structure during the zinc hydroxide precipitation whereas those chlorides, which are not embedded can be washed out. Another reason why a combination of both theories is reasonable is the result of the repulp campaign (see chapter 8.2 for more description of the repulp campaign). The zinc cake of
38
F11D showed a moderate product quality (Zn 34%, Mg 4%, Cl 8%). When it was taken to be blended with water and filtered again, the product quality increased significantly (Zn 52%, Mg 4%, Cl 3%). Future studies are necessary in order to evaluate the feasibility of this two-step process. The necessity of further evaluation of the repulp campaign is due to its low zinc recovery efficiency from the fly ash to the final product (23% figure 9.14). Whereas a pH value of 7-8 was found to be profitable towards a high quality product (chapter 9.1) the pilot project didn’t show a trend towards a preferred pH value for the P&F campaign (table 9.4). Future studies, considering further elements in the zinc cake product are necessary in order to evaluate the best pH value. Most of the products with high qualities were gained through a prefill with sodium hydroxide solution (table 9.4). Future studies in the crystal structure are necessary in order to evaluate why this method is superior to a prefill with zinc liquid. A 1 h suspension blending time and a longer cake build up time seem profitable for the zinc cake quality (table 9.4).
Camp.
Factor for
best
product
Zn Prec. Washing
[min] pH
Zn Liq.
prefill
NaOH
prefill
1h
blend
Cake
build up
[min]
F16D 48,6% 50,0% - 36 7 - x x 22
F6C 41,1% 48,0% - 8 9 x - - 9
F15D 35,4% 45,0% x 23 9 - x x 22
F17D 32,4% 46,0% - 35 8 - x x 19
F18K 32,1% 44,0% - 37 10 - x x 36
F19K 31,7% 42,0% - 37 8 - x x 37
F7C 27,8% 42,0% - 24 9 x - - 14
F3A 26,5% 42,0% - 8 9 x - - 12
F11D 22,5% 34,0% - 0 9 x - - 13
F9K 21,2% 36,0% - 12 9 x - - 10
F10I 20,7% 38,0% - 6 9 x - - 9
F14D 17,8% 40,0% - 24 9 - x x 17
F8K 15,5% 32,0% - 10 9 x - - 12
F5A 9,1% 30,0% - 8 10 x - - 10
F2B 5,7% 31,0% - 14 9 x - - 21
F1B 3,7% 32,0% - 12 9 x - - 30
F4A 0,0% 26,0% - 5 9 x - - 16
F13C -3,1% 38,0% x 20 8 - x x 22
F12C -6,8% 37,0% x 18 10 - x x 26
Table 9.4: Parameters, influencing the zinc cake product quality
In total it can be said that the production of a zinc product from Waste-to-Energy fly ash was successfully accomplished. The zinc cake product shows potential to be sold to other industries. Industries of interest might be those, which upgrade zinc from zinc ores e.g. Boliden. The final report of this project will evaluate if zinc cake product can be sold. In case that it is not possible to sell the current product, variations in the leaching and P&F process can be done in order to full fill different content criteria.
39
Another alternative might be that Renova AB develops an internal process in order to upgrade the zinc cake product to high purity zinc metal.
10. Conclusion
A high zinc containing end product could be gained through the leaching of fly ash using plant internal scrubber liquids. The Pilot Plant:
A zinc leaching from fly ash is possible in a process scale using 100 kg/h of fly ash. A zinc precipitation and filtration is possible in a batch process using 100 litre of zinc
liquid from the leaching process. The results for the zinc leaching efficiency from the fly ash to the zinc liquid filtrate
are: Maximum 74%; Average 60%; Minimum 47% The zinc P&F efficiencies from the zinc liquid to the zinc cake product are: Maximum
100%; Average 82%; Minimum 64% The total zinc recovery efficiencies from the fly ash to the zinc cake product are:
Maximum 72%; Average 53%; Minimum 41% Laboratory experiments:
pH values of 7 and 8 might lead to a lower magnesium content in the zinc product. pH values of 9 and 10 showed a higher zinc content in the end product but also a
lower product quality due to a high magnesium content. Pilot Plant Leaching:
pH values towards 3.7 showed a high zinc leaching efficiency and a lower magnesium leaching than pH values towards 3.2.
A residence time of 10 minutes is sufficient for the leaching process of zinc. A L/S of 5 ensures a stable process.
Pilot Plant P&F:
A flocculent is not needed for the P&F experiments as it showed no effect on the filtration ability.
A cake build up time from 8 to 20 minutes is preferred in order to ensure a high zinc content in the final product.
Low washing of the zinc cake leads to a higher content of zinc in the final product. Product Quality:
Precoating shall be avoided as it might lead to a lower product quality due to a higher chloride content.
A washing of the zinc cake increases the product quality as it decreases the chloride content.
40
A prefill of sodium hydroxide decreases the magnesium content and leads therefore to a high quality of the final product.
Other conclusions:
A high regular maintenance of the equipment for the leaching process is necessary in order to prevent agglomeration of fly ash and gypsum.
11. Outlook
Future studies would be interesting in:
a two-step leaching process in order to minimize the chloride content in the zinc cake end product and higher zinc leaching efficiency from the fly ash
a pH value of 4.2 for the leaching campaign a combination of zinc recovery and the recovery of salts from fly ash the crystal structure of zinc hydroxides at different prefill methods at the P&F
experiments cost analysation:, which process optimization are feasible towards a high quality end
product feasibility for Renova AB to process the zinc product through electrolysis the repulp method during P&F the back delivery of the ash residue into the furnace further usage of the ash residue
ix
References
Andersson, S., GMAB, Personal communication through E-mail (2016-03-10) Andersson, S., Blomqvist, E. W., Bäfver, L., Jones, F., Davidsson, K., Froitzheim, J., Karlsson, M., Larsson, E., Liske, J., (2013), Sulfur recirculation for increased electricity
production in Waste-to-Energy plants Waste Management 34 Avfall Sverige Utveckling, (2015) Hantering av flygaska från avfallsförbränning. Dagens
hantering och framtida vägval Rapport 2015:27, ISSN 1103-4092 Avfall Sverige AB, (2012) Svensk Avfallshantering 2012, Avfall Sverige, Malmö, Sverige, http://www.avfallsverige.se/fileadmin/uploads/Arbete/Nyhetsbrev/SAH_2012.pdf BSH Umweltservice AG (2013), http://www.bsh.ch/de/home.aspx (2013-10-22). Boliden Group (2013) Mineraltillgångar och mineralreserver, http://www.boliden.com/Documents/Operations/Exploration/Malmbas_2012-12-31_tillgangar_SV.pdf and http://www.boliden.com/Documents/Operations/Exploration/Malmbas_2012-12- 31_reserver_SV.pdf (2013-09-17). Flyhammar, P., personal conversation 2013, Avfall Sverige Hansson, D. (2013) När är svenska deponier sluttäckta? Askdagen 2013, Svenska Energiaskor, Stockholm, 17 April 2013, http://www.energiaskor.se/pdf-dokument/Askdagen2013/Presentation%20askdagen%20David%20Hansson.pdf Boliden Group, Mineralreserver (2013-11-26). Hoffland Env. (2012) http://www.hofflandenv.com/hydroxide-precipitation/ (2016-06-04) Hoornweg, D. & Bhada-Tata, P., (2012) What a waste – A global review of solid waste
management, Urban development series knowledge papers, The world bank Johansson, I. (2012), Avfall Sverige AB, Uppdaterad 2012-08-03 Inge Johansson http://www.avfallsverige.se/avfallshantering/energiaatervinning/anlaeggningar/ (2016-02-26) NOAH AS, (2012) Deponiene på Langøya, Holmestrand, Norge, http://www.noah.no/ OmNOAH/OmLangøya/tabid/554/Default.aspx (2012-10-18) EPA, (1980) Control and Treatment Technology for the Metal Finishing Industry Sulfide
Precipitation, Summary Report, April 1980
x
Kalogirou, E.,Themelis, N., Samaras, P., Karagiannidis, A. (2013) Fly Ash Characteristics
From Waste-to-Energy Facilities and Processes For Ash Stabilization
Materials science forum, (2014) Yamagata, C., Systematic Precipitation of Magnesium
Hydroxide Using NH4OH to Preparing MgO-PSZ Precursor Powder, ISSN: 0255-5476 Pettersson, A., Karfeldt Fedje, K., Andersson, S., Modin, O., Frändegård, P., (2013) Metallutvinning med fokus på Zn från avfallsflygaska med hjälp av sura processvatten. SP Sverige Tekniska Forskningsinstitut. Slutrapport: WR-58. Borås Preiss, M. K., (2013) Method Development to recover Zinc from Fly Ash originating from
Municipal Solid Waste Incineration in Sweden, University of Borås, Master thesis Renova AB, (2013) Miljörapport 2012 för avfallskraftvärmeverket och
sorteringsanläggningen, inklusive återvinningscentralen vid Sävenäs http://www.renova.se/Global/pdf/Miljorapport_2012.pdf (2013-10-01). Samuelsson, P.-O., Magnusson, G., Bengtsson, H., Seland, M., Karlsson, M., (2013) Miljögifter och muddring. Hav möter Land, Länsstyrelsen i Västra Götalands län. Slutrapport från temagrupp 3.6 Schecter, A., Birnbaum, L., Ryan, J. J., Constable J. D., (2006) Dioxins: An overview, Science Direct, Environmental Research, Elsevier Schlumberger, S., Bühler, J., (2012) Metal recovery in fly and filter ash in waste to energy
plants. Ash, Stockholm, Sweden, 25-27 January 2012. Schlumberger, S., Schuster, M., Ringmann, S., Koralewska, R. (2007) Recovery of high
purity zinc from filter ash produced during the thermal treatment of waste and
inerting of residual materials. Waste management and research. 2007, 25, 547-555. Separation Science and Technology, (2009) Vian, A., Rodriguez, J.J., Guardiola E., Zinc
Oxide Extraction from Pyrite Ashes Leaching Liquors, ISSN: 0149-6395 Steenari, B.-M., Zhao, D., (2010) Vattentvätt av flygaska från avfallsförbränning, Projektnummer WR-17, Waste Refinery, ISSN 1654-4706. TETRA Technologies, Inc., (2007) Engineered Solution Guide http://solutionsguide.tetratec.com/index.asp?Page_ID=730&AQ_Magazine_Date=Current&AQ_Magazine_ID=2195 (2016-02-26)
xi
Thomé-Kozmiensky, K. J., (1994) Thermische Abfallbehandlung, EF-Verlag für Energie- und Umwelttechnik GmbH Top, A., Cetinkaya, H. (2015) Zinc oxide and zinc hydroxide formation via aqueous
precipitation: Effect of the preparation route and lysozyme addition, Materials Chemistry and Physics 167, p. 77-87 Vehlow, J., Braun, H., Fahlenkamp, H., Merz, A., Schneider, J., Stieglitz, L., Vogg, H. (1991) Das 3R-Verfahren zur Behandlung von Stäuben aus der Müllverbrennung
xii
Appendix 1: Calculations
[1] L/S � = �� � [ /ℎ]ℎ [ /ℎ]
[2] Residence time
[ � ] = � � � [ ] � [ /ℎ] ∗
[3] Leaching efficiency Zinc
It is estimated that the content of silicon is not effected by the leaching treatment. By using this factor it can be estimated how much of the total fly ash is transferred from the solid to the liquid phase. The silicon content can also be used to determinate the actual leaching efficiency of zinc: � ℎ� � [%] = − ( ∗∗ ) ∗
[ ] = � � ℎ [ ] ∗ − � � ℎ %
[ ] = � � ℎ [ ] ∗ − � � ℎ %
[ ] = � � � ℎ [ ] ∗ − � � ℎ %
[ ] = � � � ℎ [ ] ∗ − � � ℎ %
[4] Factor for Fly Ash from kg to litre
It is measured: ℎ ≜ ℎ
0,4754 g/ml or 0,4754 kg/l
xiii
[5] Figure 8.6
For Fly Ash content concentration: results from Eurofins tables [mg/kg] * 0,4754 kg/l mg/l [6] Precipitation and Filtration rate Zinc
Assumption 1l suspension = 1kg suspension
[%] = � � � � [ ] ∗ [%] ∗ � [ ]� [ ] ∗ � � � [ ] ∗
Ts = dry substance
[7] Total zinc recovery
� [%] =
D = zinc mass in zinc cake from 100 kg fly ash [kg] G = Zinc mass in 100 kg fly ash [kg] = ∗
A= fly ash mass used in leaching campaign to obtain zinc cake in P&F [kg] H = zinc mass in resp. zinc cake [kg] = . �& [ ]�⁄ . ℎ� �
= ∗ � � . �& [ ] I = zinc content [g/kgwetcake] = � [ ] ∗⁄ [%]
xiv
Appendix 2: Eurofins Result Tables
Appendix 3: Tables from Excel
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
Analysrapport
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-168378-01
EUSELI2-00284517
Kundnummer: SL8420465
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10090700
Aska
2015-10-09
2015-10-22
Provmärkning: 1 Aska
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
a)
0.8Fukthalt % 10% EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
a)
10.91Klor Cl % Ts 15% SS 187185 a)*
22000Aluminium Al mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
41000Aluminiumoxid Al2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
6500Fosfor P mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
15000Fosforoxid P2O5 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
15000Järn Fe mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
21000Järnoxid Fe2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
260Kadmium Cd mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
160000Kalcium Ca mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
220000Kalciumoxid CaO mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
58000Kalium K mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
70000Kaliumoxid K2O mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
52000Kisel Si mg/kg Ts 20% EN 14385 / ICP-AES a)*
110000Kiseloxid SiO2 mg/kg Ts 30% EN 14385 a)*
11000Magnesium Mg mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
19000Magnesiumoxid MgO mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
690Mangan Mn mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1100Manganoxid MnO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
64000Natrium Na mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
87000Natriumoxid Na2O mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
11000Titan Ti mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
18000Titanoxid TiO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1700Arsenik As mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
1600Antimon Sb mg/kg Ts 15% EN 13656 mod. / ICP-MS a)
1300Barium Ba mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
< 2.6Berylium Be mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
6200Bly Pb mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
26Kobolt Co mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
2600Koppar Cu mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
530Krom Cr mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
30Molybden Mo mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
99Nickel Ni mg/kg Ts 35% EN 13656 mod. / ICP-MS a)
55000Svavel S mg/kg Ts 25% EN 13656 mod. / ICP-AES a)*
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
AR-15-SL-168378-01
EUSELI2-00284517
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10090700
Aska
2015-10-09
2015-10-22
Provmärkning: 1 Aska
Analys Resultat Enhet Metod/refMäto.
1000Tenn Sn mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
45Vanadin mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
25000Zink Zn mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
220Bor B mg/kg Ts 15% SS 028150-2 / ICP-AES a)*
0.88Kvicksilver Hg mg/kg Ts 25% SS 028150-2 / AFS a)*
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Lars Rosengren, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Johanna Eriksson ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
Analysrapport
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-168379-01
EUSELI2-00284517
Kundnummer: SL8420465
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10090701
Aska
2015-10-09
2015-10-22
Provmärkning: 1 Askrest
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
a)
36.9Fukthalt % 10% EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
a)
0.27Klor Cl % Ts 15% SS 187185 a)*
42000Aluminium Al mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
80000Aluminiumoxid Al2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
9400Fosfor P mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
21000Fosforoxid P2O5 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
20000Järn Fe mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
29000Järnoxid Fe2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
88Kadmium Cd mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
220000Kalcium Ca mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
300000Kalciumoxid CaO mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
7700Kalium K mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
9200Kaliumoxid K2O mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
87000Kisel Si mg/kg Ts 20% EN 14385 / ICP-AES a)*
190000Kiseloxid SiO2 mg/kg Ts 30% EN 14385 a)*
13000Magnesium Mg mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
21000Magnesiumoxid MgO mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
840Mangan Mn mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1300Manganoxid MnO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
7300Natrium Na mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
9900Natriumoxid Na2O mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
15000Titan Ti mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
25000Titanoxid TiO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
2400Arsenik As mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
2400Antimon Sb mg/kg Ts 15% EN 13656 mod. / ICP-MS a)
650Barium Ba mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
< 2.8Berylium Be mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
7500Bly Pb mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
29Kobolt Co mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
3300Koppar Cu mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
860Krom Cr mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
37Molybden Mo mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
160Nickel Ni mg/kg Ts 35% EN 13656 mod. / ICP-MS a)
79000Svavel S mg/kg Ts 25% EN 13656 mod. / ICP-AES a)*
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
AR-15-SL-168379-01
EUSELI2-00284517
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10090701
Aska
2015-10-09
2015-10-22
Provmärkning: 1 Askrest
Analys Resultat Enhet Metod/refMäto.
1500Tenn Sn mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
61Vanadin mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
18000Zink Zn mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
140Bor B mg/kg Ts 15% SS 028150-2 / ICP-AES a)*
4.4Kvicksilver Hg mg/kg Ts 25% SS 028150-2 / AFS a)*
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Lars Rosengren, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Johanna Eriksson ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB
(Lidköping)
Box 887Sjöhagsg. 3SE-53119 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8390
AR-15-SL-171563-01
EUSELI2-00284953
Analysrapport
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2015-10130173Provnummer:
Provet ankom:
Övrigt förorenat vattenMatris:
2015-10-07
Utskriftsdatum: 2015-10-28
Provmärkning: Filtrat
Analys Resultat Enhet Metod/refMäto.
mg/l78000Klorid a)SS-EN ISO 10304-1:200910%
mg/l25000Natrium Na (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l22000Kalium K (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l11000Kalcium Ca (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
15%
mg/l7.0Järn Fe (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
25%
mg/l1300Magnesium Mg (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l44Mangan Mn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l18Aluminium Al (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
15%
mg/l10Antimon, Sb (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
25%
mg/l8.6Arsenik As (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l15Barium Ba (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l< 0.0020Beryllium Be (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
35%
mg/l76Bly Pb (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 3
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v37
AR-15-SL-171563-01
EUSELI2-00284953
mg/l52Bor, B (uppsluten) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l< 120Fosfor P (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l73Kadmium Cd (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l< 200Kisel, Si (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
15%
mg/l0.96Kobolt Co (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l5.7Koppar Cu (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
15%
mg/l0.43Krom Cr (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
25%
mg/l< 20Litium, Li (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
25%
mg/l0.47Molybden, Mo (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l0.59Nickel Ni (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
15%
mg/l0.034Selen, Se (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
35%
mg/l0.082Silver Ag (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l32Strontium, Sr (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l740Svavel, S (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.35Tallium, Tl (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l2.0Tenn Sn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l< 20Titan, Ti (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.00094Uran U (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l0.24Vanadin V (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l5400Zink Zn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
Kemisk kommentarHöjd rapporteringsgräns för metaller på grund av svår matris.
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 3
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v37
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-170640-01
EUSELI2-00285422
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10140390
Aska
2015-10-14
2015-10-27
Provtagare Sven Andersson
Provmärkning: Aska
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
a)
0.7Fukthalt % 10% EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
a)
11.93Klor Cl % Ts 15% SS 187185 a)*
31000Aluminium Al mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
59000Aluminiumoxid Al2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
6800Fosfor P mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
16000Fosforoxid P2O5 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
15000Järn Fe mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
22000Järnoxid Fe2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
250Kadmium Cd mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
180000Kalcium Ca mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
260000Kalciumoxid CaO mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
37000Kalium K mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
44000Kaliumoxid K2O mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
49000Kisel Si mg/kg Ts 20% EN 14385 / ICP-AES a)*
110000Kiseloxid SiO2 mg/kg Ts 30% EN 14385 a)*
12000Magnesium Mg mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
20000Magnesiumoxid MgO mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
680Mangan Mn mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1100Manganoxid MnO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
66000Natrium Na mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
89000Natriumoxid Na2O mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
11000Titan Ti mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
19000Titanoxid TiO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1600Arsenik As mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
1500Antimon Sb mg/kg Ts 15% EN 13656 mod. / ICP-MS a)
1100Barium Ba mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
< 2.6Berylium Be mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
6100Bly Pb mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
23Kobolt Co mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
2600Koppar Cu mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
650Krom Cr mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
30Molybden Mo mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
86Nickel Ni mg/kg Ts 35% EN 13656 mod. / ICP-MS a)
56000Svavel S mg/kg Ts 25% EN 13656 mod. / ICP-AES a)*
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
AR-15-SL-170640-01
EUSELI2-00285422
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10140390
Aska
2015-10-14
2015-10-27
Provtagare Sven Andersson
Provmärkning: Aska
Analys Resultat Enhet Metod/refMäto.
1000Tenn Sn mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
43Vanadin mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
25000Zink Zn mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
210Bor B mg/kg Ts 15% SS 028150-2 / ICP-AES a)*
0.93Kvicksilver Hg mg/kg Ts 25% SS 028150-2 / AFS a)*
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Lars Rosengren, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Johanna Eriksson ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-170641-01
EUSELI2-00285422
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10140391
Aska
2015-10-14
2015-10-27
Provtagare Sven Andersson
Provmärkning: Askrest
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
a)
38.9Fukthalt % 10% EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
a)
0.51Klor Cl % Ts 15% SS 187185 a)*
46000Aluminium Al mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
87000Aluminiumoxid Al2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
9400Fosfor P mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
22000Fosforoxid P2O5 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
21000Järn Fe mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
30000Järnoxid Fe2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
110Kadmium Cd mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
220000Kalcium Ca mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
310000Kalciumoxid CaO mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
8600Kalium K mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
10000Kaliumoxid K2O mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
90000Kisel Si mg/kg Ts 20% EN 14385 / ICP-AES a)*
190000Kiseloxid SiO2 mg/kg Ts 30% EN 14385 a)*
13000Magnesium Mg mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
22000Magnesiumoxid MgO mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
830Mangan Mn mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1300Manganoxid MnO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
8500Natrium Na mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
11000Natriumoxid Na2O mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
16000Titan Ti mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
27000Titanoxid TiO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
2200Arsenik As mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
2200Antimon Sb mg/kg Ts 15% EN 13656 mod. / ICP-MS a)
680Barium Ba mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
< 2.9Berylium Be mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
9300Bly Pb mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
29Kobolt Co mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
3900Koppar Cu mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
880Krom Cr mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
45Molybden Mo mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
130Nickel Ni mg/kg Ts 35% EN 13656 mod. / ICP-MS a)
75000Svavel S mg/kg Ts 25% EN 13656 mod. / ICP-AES a)*
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
AR-15-SL-170641-01
EUSELI2-00285422
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10140391
Aska
2015-10-14
2015-10-27
Provtagare Sven Andersson
Provmärkning: Askrest
Analys Resultat Enhet Metod/refMäto.
1300Tenn Sn mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
60Vanadin mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
18000Zink Zn mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
150Bor B mg/kg Ts 15% SS 028150-2 / ICP-AES a)*
14Kvicksilver Hg mg/kg Ts 25% SS 028150-2 / AFS a)*
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Lars Rosengren, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Johanna Eriksson ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB
(Lidköping)
Box 887Sjöhagsg. 3SE-53119 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8390
AR-15-SL-171544-01
EUSELI2-00285339
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2015-10140178Provnummer: Provtagare Sven Andersson
Provet ankom:
Övrigt förorenat vattenMatris:
2015-10-13
Utskriftsdatum: 2015-10-28
Provmärkning: filtrat
Analys Resultat Enhet Metod/refMäto.
mg/l68000Klorid a)SS-EN ISO 10304-1:200910%
mg/l23000Natrium Na (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l20000Kalium K (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l9300Kalcium Ca (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
15%
mg/l3.6Järn Fe (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
25%
mg/l1100Magnesium Mg (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l39Mangan Mn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l8.3Aluminium Al (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
15%
mg/l8.6Antimon, Sb (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
25%
mg/l7.2Arsenik As (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l13Barium Ba (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l< 0.0020Beryllium Be (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
35%
mg/l91Bly Pb (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 3
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v37
AR-15-SL-171544-01
EUSELI2-00285339
mg/l47Bor, B (uppsluten) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l< 120Fosfor P (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l68Kadmium Cd (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l< 200Kisel, Si (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
15%
mg/l0.88Kobolt Co (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l8.2Koppar Cu (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.25Krom Cr (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
25%
mg/l< 20Litium, Li (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
25%
mg/l0.53Molybden, Mo (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l0.60Nickel Ni (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
15%
mg/l0.035Selen, Se (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
35%
mg/l0.091Silver Ag (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l28Strontium, Sr (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l800Svavel, S (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.33Tallium, Tl (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l0.87Tenn Sn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l< 20Titan, Ti (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.00055Uran U (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l0.19Vanadin V (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l4500Zink Zn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
Kemisk kommentarHöjd rapporteringsgräns för metaller på grund av svår matris.
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 3
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v37
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-174464-01
EUSELI2-00286971
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10200894
Aska
2015-10-19
2015-11-02
Provtagare Sven Andersson
Provmärkning: Aska C
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
a)
0.9Fukthalt % 10% EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
a)
8.88Klor Cl % Ts 15% SS 187185 a)*
31000Aluminium Al mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
59000Aluminiumoxid Al2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
7000Fosfor P mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
16000Fosforoxid P2O5 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
16000Järn Fe mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
23000Järnoxid Fe2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
250Kadmium Cd mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
190000Kalcium Ca mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
270000Kalciumoxid CaO mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
63000Kalium K mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
76000Kaliumoxid K2O mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
50000Kisel Si mg/kg Ts 20% EN 14385 / ICP-AES a)*
110000Kiseloxid SiO2 mg/kg Ts 30% EN 14385 a)*
12000Magnesium Mg mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
20000Magnesiumoxid MgO mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
720Mangan Mn mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1100Manganoxid MnO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
66000Natrium Na mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
88000Natriumoxid Na2O mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
12000Titan Ti mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
19000Titanoxid TiO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1600Arsenik As mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
1600Antimon Sb mg/kg Ts 15% EN 13656 mod. / ICP-MS a)
1200Barium Ba mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
< 2.6Berylium Be mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
6200Bly Pb mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
24Kobolt Co mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
2600Koppar Cu mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
620Krom Cr mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
32Molybden Mo mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
110Nickel Ni mg/kg Ts 35% EN 13656 mod. / ICP-MS a)
55000Svavel S mg/kg Ts 25% EN 13656 mod. / ICP-AES a)*
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
AR-15-SL-174464-01
EUSELI2-00286971
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10200894
Aska
2015-10-19
2015-11-02
Provtagare Sven Andersson
Provmärkning: Aska C
Analys Resultat Enhet Metod/refMäto.
950Tenn Sn mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
45Vanadin mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
26000Zink Zn mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
210Bor B mg/kg Ts 15% SS 028150-2 / ICP-AES a)*
0.86Kvicksilver Hg mg/kg Ts 25% SS 028150-2 / AFS a)*
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Mikael Sandin, Rapportansvarig
Denna rapport är elektroniskt signerad.
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-174466-01
EUSELI2-00286971
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10200896
Aska
2015-10-19
2015-11-02
Provtagare Sven Andersson
Provmärkning: Askrest C
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
a)
39.7Fukthalt % 10% EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
a)
0.53Klor Cl % Ts 15% SS 187185 a)*
47000Aluminium Al mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
89000Aluminiumoxid Al2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
10000Fosfor P mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
23000Fosforoxid P2O5 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
24000Järn Fe mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
34000Järnoxid Fe2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
100Kadmium Cd mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
240000Kalcium Ca mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
340000Kalciumoxid CaO mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
9100Kalium K mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
11000Kaliumoxid K2O mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
86000Kisel Si mg/kg Ts 20% EN 14385 / ICP-AES a)*
180000Kiseloxid SiO2 mg/kg Ts 30% EN 14385 a)*
13000Magnesium Mg mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
21000Magnesiumoxid MgO mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
860Mangan Mn mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1400Manganoxid MnO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
8800Natrium Na mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
12000Natriumoxid Na2O mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
16000Titan Ti mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
27000Titanoxid TiO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
2300Arsenik As mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
2400Antimon Sb mg/kg Ts 15% EN 13656 mod. / ICP-MS a)
410Barium Ba mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
< 2.8Berylium Be mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
8700Bly Pb mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
29Kobolt Co mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
3700Koppar Cu mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
730Krom Cr mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
43Molybden Mo mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
120Nickel Ni mg/kg Ts 35% EN 13656 mod. / ICP-MS a)
79000Svavel S mg/kg Ts 25% EN 13656 mod. / ICP-AES a)*
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
AR-15-SL-174466-01
EUSELI2-00286971
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10200896
Aska
2015-10-19
2015-11-02
Provtagare Sven Andersson
Provmärkning: Askrest C
Analys Resultat Enhet Metod/refMäto.
1400Tenn Sn mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
64Vanadin mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
19000Zink Zn mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
150Bor B mg/kg Ts 15% SS 028150-2 / ICP-AES a)*
0.13Kvicksilver Hg mg/kg Ts 25% SS 028150-2 / AFS a)*
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Mikael Sandin, Rapportansvarig
Denna rapport är elektroniskt signerad.
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB
(Lidköping)
Box 887Sjöhagsg. 3SE-53119 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8390
AR-15-SL-176484-01
EUSELI2-00286790
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2015-10200124Provnummer: Provtagare Sven Andersson
Provet ankom:
Övrigt förorenat vattenMatris:
2015-10-19
Utskriftsdatum: 2015-11-04
Provmärkning: Filtrat C
Analys Resultat Enhet Metod/refMäto.
mg/l61000Klorid a)SS-EN ISO 10304-1:200910%
mg/l21000Natrium Na (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l19000Kalium K (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l9300Kalcium Ca (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
15%
mg/l5.5Järn Fe (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
25%
mg/l1100Magnesium Mg (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l39Mangan Mn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l13Aluminium Al (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
15%
mg/l9.1Antimon, Sb (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
25%
mg/l7.2Arsenik As (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l11Barium Ba (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l< 0.0020Beryllium Be (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
35%
mg/l61Bly Pb (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 3
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v37
AR-15-SL-176484-01
EUSELI2-00286790
mg/l45Bor, B (uppsluten) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l< 120Fosfor P (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l66Kadmium Cd (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l< 200Kisel, Si (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
15%
mg/l0.83Kobolt Co (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l4.7Koppar Cu (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
15%
mg/l0.34Krom Cr (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
25%
mg/l< 20Litium, Li (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
25%
mg/l0.44Molybden, Mo (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l0.49Nickel Ni (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
15%
mg/l0.033Selen, Se (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
35%
mg/l0.065Silver Ag (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l28Strontium, Sr (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l850Svavel, S (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.28Tallium, Tl (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l1.6Tenn Sn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
µg/l< 20000Titan, Ti (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.00071Uran U (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l0.20Vanadin V (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l4700Zink Zn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
Kemisk kommentarHöjd rapporteringsgräns för metaller på grund av svår matris.
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 3
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v37
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-174465-01
EUSELI2-00286971
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10200895
Aska
2015-10-19
2015-11-02
Provtagare Sven Andersson
Provmärkning: Aska D
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
a)
1.0Fukthalt % 10% EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
a)
9.38Klor Cl % Ts 15% SS 187185 a)*
33000Aluminium Al mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
63000Aluminiumoxid Al2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
7300Fosfor P mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
17000Fosforoxid P2O5 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
17000Järn Fe mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
24000Järnoxid Fe2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
270Kadmium Cd mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
200000Kalcium Ca mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
280000Kalciumoxid CaO mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
65000Kalium K mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
78000Kaliumoxid K2O mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
48000Kisel Si mg/kg Ts 20% EN 14385 / ICP-AES a)*
100000Kiseloxid SiO2 mg/kg Ts 30% EN 14385 a)*
12000Magnesium Mg mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
21000Magnesiumoxid MgO mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
740Mangan Mn mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1200Manganoxid MnO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
68000Natrium Na mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
92000Natriumoxid Na2O mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
11000Titan Ti mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
19000Titanoxid TiO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1700Arsenik As mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
1600Antimon Sb mg/kg Ts 15% EN 13656 mod. / ICP-MS a)
1400Barium Ba mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
< 2.6Berylium Be mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
6800Bly Pb mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
24Kobolt Co mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
2600Koppar Cu mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
500Krom Cr mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
31Molybden Mo mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
93Nickel Ni mg/kg Ts 35% EN 13656 mod. / ICP-MS a)
57000Svavel S mg/kg Ts 25% EN 13656 mod. / ICP-AES a)*
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
AR-15-SL-174465-01
EUSELI2-00286971
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10200895
Aska
2015-10-19
2015-11-02
Provtagare Sven Andersson
Provmärkning: Aska D
Analys Resultat Enhet Metod/refMäto.
970Tenn Sn mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
46Vanadin mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
28000Zink Zn mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
210Bor B mg/kg Ts 15% SS 028150-2 / ICP-AES a)*
0.85Kvicksilver Hg mg/kg Ts 25% SS 028150-2 / AFS a)*
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Mikael Sandin, Rapportansvarig
Denna rapport är elektroniskt signerad.
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-174467-01
EUSELI2-00286971
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10200897
Aska
2015-10-19
2015-11-02
Provtagare Sven Andersson
Provmärkning: Askrest D
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
a)
36.3Fukthalt % 10% EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
a)
0.28Klor Cl % Ts 15% SS 187185 a)*
40000Aluminium Al mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
75000Aluminiumoxid Al2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
8000Fosfor P mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
18000Fosforoxid P2O5 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
19000Järn Fe mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
28000Järnoxid Fe2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
58Kadmium Cd mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
220000Kalcium Ca mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
310000Kalciumoxid CaO mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
6800Kalium K mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
8100Kaliumoxid K2O mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
93000Kisel Si mg/kg Ts 20% EN 14385 / ICP-AES a)*
200000Kiseloxid SiO2 mg/kg Ts 30% EN 14385 a)*
11000Magnesium Mg mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
19000Magnesiumoxid MgO mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
710Mangan Mn mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1100Manganoxid MnO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
7100Natrium Na mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
9600Natriumoxid Na2O mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
14000Titan Ti mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
24000Titanoxid TiO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1900Arsenik As mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
2100Antimon Sb mg/kg Ts 15% EN 13656 mod. / ICP-MS a)
1600Barium Ba mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
< 2.8Berylium Be mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
7000Bly Pb mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
24Kobolt Co mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
3300Koppar Cu mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
890Krom Cr mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
36Molybden Mo mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
90Nickel Ni mg/kg Ts 35% EN 13656 mod. / ICP-MS a)
85000Svavel S mg/kg Ts 25% EN 13656 mod. / ICP-AES a)*
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
AR-15-SL-174467-01
EUSELI2-00286971
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10200897
Aska
2015-10-19
2015-11-02
Provtagare Sven Andersson
Provmärkning: Askrest D
Analys Resultat Enhet Metod/refMäto.
1300Tenn Sn mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
52Vanadin mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
14000Zink Zn mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
140Bor B mg/kg Ts 15% SS 028150-2 / ICP-AES a)*
4.2Kvicksilver Hg mg/kg Ts 25% SS 028150-2 / AFS a)*
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Mikael Sandin, Rapportansvarig
Denna rapport är elektroniskt signerad.
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB
(Lidköping)
Box 887Sjöhagsg. 3SE-53119 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8390
AR-15-SL-176487-01
EUSELI2-00286790
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2015-10200127Provnummer: Provtagare Sven Andersson
Provet ankom:
Övrigt förorenat vattenMatris:
2015-10-19
Utskriftsdatum: 2015-11-04
Provmärkning: Filtrat D
Analys Resultat Enhet Metod/refMäto.
mg/l42000Klorid a)SS-EN ISO 10304-1:200910%
mg/l26000Natrium Na (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l12000Kalium K (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l1100Kalcium Ca (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
15%
mg/l13Järn Fe (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l650Magnesium Mg (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l24Mangan Mn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l74Aluminium Al (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
15%
mg/l12Antimon, Sb (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
25%
mg/l4.2Arsenik As (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l1.8Barium Ba (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l0.0043Beryllium Be (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
35%
mg/l110Bly Pb (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 3
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v37
AR-15-SL-176487-01
EUSELI2-00286790
mg/l26Bor, B (uppsluten) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l< 120Fosfor P (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l46Kadmium Cd (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l320Kisel, Si (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
15%
mg/l0.59Kobolt Co (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l15Koppar Cu (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.38Krom Cr (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
25%
mg/l< 20Litium, Li (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
25%
mg/l0.33Molybden, Mo (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l0.79Nickel Ni (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
15%
mg/l0.045Selen, Se (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
35%
mg/l0.14Silver Ag (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l4.7Strontium, Sr (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
15%
mg/l5900Svavel, S (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.22Tallium, Tl (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l1.4Tenn Sn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
µg/l< 20000Titan, Ti (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.0014Uran U (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l0.27Vanadin V (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l3200Zink Zn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
Kemisk kommentarHöjd rapporteringsgräns för metaller på grund av svår matris.
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 3
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v37
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-178635-01
EUSELI2-00288505
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10270158
Aska
2015-10-23
2015-11-06
Provtagare Sven Andersson
Provmärkning: Aska KE
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
a)
0.8Fukthalt % 10% EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
a)
11.52Klor Cl % Ts 15% SS 187185 a)*
33000Aluminium Al mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
62000Aluminiumoxid Al2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
6600Fosfor P mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
15000Fosforoxid P2O5 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
17000Järn Fe mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
24000Järnoxid Fe2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
260Kadmium Cd mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
190000Kalcium Ca mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
270000Kalciumoxid CaO mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
58000Kalium K mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
70000Kaliumoxid K2O mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
51000Kisel Si mg/kg Ts 20% EN 14385 / ICP-AES a)*
110000Kiseloxid SiO2 mg/kg Ts 30% EN 14385 a)*
12000Magnesium Mg mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
20000Magnesiumoxid MgO mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
690Mangan Mn mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1100Manganoxid MnO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
67000Natrium Na mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
90000Natriumoxid Na2O mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
11000Titan Ti mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
19000Titanoxid TiO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1600Arsenik As mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
1600Antimon Sb mg/kg Ts 15% EN 13656 mod. / ICP-MS a)
1200Barium Ba mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
< 2.6Berylium Be mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
6700Bly Pb mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
24Kobolt Co mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
2700Koppar Cu mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
580Krom Cr mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
23Molybden Mo mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
85Nickel Ni mg/kg Ts 35% EN 13656 mod. / ICP-MS a)
1000Tenn Sn mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
AR-15-SL-178635-01
EUSELI2-00288505
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10270158
Aska
2015-10-23
2015-11-06
Provtagare Sven Andersson
Provmärkning: Aska KE
Analys Resultat Enhet Metod/refMäto.
48Vanadin mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
26000Zink Zn mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
200Bor B mg/kg Ts 15% SS 028150-2 / ICP-AES a)*
0.62Kvicksilver Hg mg/kg Ts 25% SS 028150-2 / AFS a)*
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Mikael Sandin, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Karin Karlfeldt-Fedje ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-178636-01
EUSELI2-00288505
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10270159
Aska
2015-10-23
2015-11-06
Provtagare Sven Andersson
Provmärkning: Askrest KE
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
a)
46.3Fukthalt % 10% EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
a)
0.70Klor Cl % Ts 15% SS 187185 a)*
43000Aluminium Al mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
81000Aluminiumoxid Al2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
8500Fosfor P mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
20000Fosforoxid P2O5 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
22000Järn Fe mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
31000Järnoxid Fe2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
340Kadmium Cd mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
240000Kalcium Ca mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
340000Kalciumoxid CaO mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
9400Kalium K mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
11000Kaliumoxid K2O mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
89000Kisel Si mg/kg Ts 20% EN 14385 / ICP-AES a)*
190000Kiseloxid SiO2 mg/kg Ts 30% EN 14385 a)*
16000Magnesium Mg mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
27000Magnesiumoxid MgO mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
880Mangan Mn mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1400Manganoxid MnO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
11000Natrium Na mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
15000Natriumoxid Na2O mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
16000Titan Ti mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
27000Titanoxid TiO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
2100Arsenik As mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
2300Antimon Sb mg/kg Ts 15% EN 13656 mod. / ICP-MS a)
1300Barium Ba mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
< 2.7Berylium Be mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
8500Bly Pb mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
32Kobolt Co mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
3400Koppar Cu mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
840Krom Cr mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
29Molybden Mo mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
120Nickel Ni mg/kg Ts 35% EN 13656 mod. / ICP-MS a)
1300Tenn Sn mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
AR-15-SL-178636-01
EUSELI2-00288505
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-10270159
Aska
2015-10-23
2015-11-06
Provtagare Sven Andersson
Provmärkning: Askrest KE
Analys Resultat Enhet Metod/refMäto.
65Vanadin mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
34000Zink Zn mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
250Bor B mg/kg Ts 15% SS 028150-2 / ICP-AES a)*
1.0Kvicksilver Hg mg/kg Ts 25% SS 028150-2 / AFS a)*
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Mikael Sandin, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Karin Karlfeldt-Fedje ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-204183-01
EUSELI2-00297948
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11300217
Aska
2015-11-27
2015-12-11
Provtagare Sven Andersson
Provmärkning: Aska F Tidigare 177-2015-11060364
Analys Resultat Enhet Metod/refMäto.
10.59Klor Cl % Ts 15% a)*SS 187185
42000Svavel S mg/kg Ts 25% a)*EN 13656 mod. / ICP-AES
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Lars Rosengren, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Karin Karlfeldt-Fedje ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 1
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v12
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-182553-01
EUSELI2-00291775
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11060364
Aska
2015-11-06
2015-11-12
Provtagare Sven Andersson
Provmärkning: Aska F
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
a)
0.9Fukthalt % 10% EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
a)
38000Aluminium Al mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
72000Aluminiumoxid Al2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
7700Fosfor P mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
18000Fosforoxid P2O5 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
15000Järn Fe mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
22000Järnoxid Fe2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
190Kadmium Cd mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
200000Kalcium Ca mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
280000Kalciumoxid CaO mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
52000Kalium K mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
62000Kaliumoxid K2O mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
65000Kisel Si mg/kg Ts 20% EN 14385 / ICP-AES a)*
140000Kiseloxid SiO2 mg/kg Ts 30% EN 14385 a)*
15000Magnesium Mg mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
24000Magnesiumoxid MgO mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
760Mangan Mn mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1200Manganoxid MnO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
55000Natrium Na mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
74000Natriumoxid Na2O mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
14000Titan Ti mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
23000Titanoxid TiO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
710Arsenik As mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
1500Antimon Sb mg/kg Ts 15% EN 13656 mod. / ICP-MS a)
1700Barium Ba mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
< 2.6Berylium Be mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
2900Bly Pb mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
25Kobolt Co mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
1800Koppar Cu mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
580Krom Cr mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
33Molybden Mo mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
84Nickel Ni mg/kg Ts 35% EN 13656 mod. / ICP-MS a)
850Tenn Sn mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
62Vanadin mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
AR-15-SL-182553-01
EUSELI2-00291775
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11060364
Aska
2015-11-06
2015-11-12
Provtagare Sven Andersson
Provmärkning: Aska F
Analys Resultat Enhet Metod/refMäto.
23000Zink Zn mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
210Bor B mg/kg Ts 15% SS 028150-2 / ICP-AES a)*
0.49Kvicksilver Hg mg/kg Ts 25% SS 028150-2 / AFS a)*
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Mikael Sandin, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Karin Karlfeldt-Fedje ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-204185-01
EUSELI2-00297948
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11300219
Aska
2015-11-27
2015-12-11
Provtagare Sven Andersson
Provmärkning: Askrest F Tidigare 177-2015-11060366
Analys Resultat Enhet Metod/refMäto.
0.45Klor Cl % Ts 15% a)*SS 187185
65000Svavel S mg/kg Ts 25% a)*EN 13656 mod. / ICP-AES
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Lars Rosengren, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Karin Karlfeldt-Fedje ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 1
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v12
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-182555-01
EUSELI2-00291775
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11060366
Aska
2015-11-06
2015-11-12
Provtagare Sven Andersson
Provmärkning: Askrest F
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
a)
34.9Fukthalt % 10% EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
a)
46000Aluminium Al mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
87000Aluminiumoxid Al2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
8800Fosfor P mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
20000Fosforoxid P2O5 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
19000Järn Fe mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
27000Järnoxid Fe2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
72Kadmium Cd mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
200000Kalcium Ca mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
290000Kalciumoxid CaO mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
8800Kalium K mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
11000Kaliumoxid K2O mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
93000Kisel Si mg/kg Ts 20% EN 14385 / ICP-AES a)*
200000Kiseloxid SiO2 mg/kg Ts 30% EN 14385 a)*
14000Magnesium Mg mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
24000Magnesiumoxid MgO mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
800Mangan Mn mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1300Manganoxid MnO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
10000Natrium Na mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
14000Natriumoxid Na2O mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
16000Titan Ti mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
27000Titanoxid TiO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
900Arsenik As mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
1900Antimon Sb mg/kg Ts 15% EN 13656 mod. / ICP-MS a)
1600Barium Ba mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
< 2.8Berylium Be mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
3500Bly Pb mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
36Kobolt Co mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
2300Koppar Cu mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
780Krom Cr mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
35Molybden Mo mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
120Nickel Ni mg/kg Ts 35% EN 13656 mod. / ICP-MS a)
1100Tenn Sn mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
86Vanadin mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
AR-15-SL-182555-01
EUSELI2-00291775
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11060366
Aska
2015-11-06
2015-11-12
Provtagare Sven Andersson
Provmärkning: Askrest F
Analys Resultat Enhet Metod/refMäto.
14000Zink Zn mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
140Bor B mg/kg Ts 15% SS 028150-2 / ICP-AES a)*
5.4Kvicksilver Hg mg/kg Ts 25% SS 028150-2 / AFS a)*
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Mikael Sandin, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Karin Karlfeldt-Fedje ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-204184-01
EUSELI2-00297948
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11300218
Aska
2015-11-27
2015-12-11
Provtagare Sven Andersson
Provmärkning: Aska G Tidigare 177-2015-11060365
Analys Resultat Enhet Metod/refMäto.
10.87Klor Cl % Ts 15% a)*SS 187185
42000Svavel S mg/kg Ts 25% a)*EN 13656 mod. / ICP-AES
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Lars Rosengren, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Karin Karlfeldt-Fedje ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 1
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v12
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-182554-01
EUSELI2-00291775
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11060365
Aska
2015-11-06
2015-11-12
Provtagare Sven Andersson
Provmärkning: Aska G
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
a)
1.4Fukthalt % 10% EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
a)
38000Aluminium Al mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
73000Aluminiumoxid Al2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
7500Fosfor P mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
17000Fosforoxid P2O5 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
16000Järn Fe mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
23000Järnoxid Fe2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
190Kadmium Cd mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
200000Kalcium Ca mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
280000Kalciumoxid CaO mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
54000Kalium K mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
64000Kaliumoxid K2O mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
58000Kisel Si mg/kg Ts 20% EN 14385 / ICP-AES a)*
120000Kiseloxid SiO2 mg/kg Ts 30% EN 14385 a)*
14000Magnesium Mg mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
24000Magnesiumoxid MgO mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
750Mangan Mn mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1200Manganoxid MnO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
56000Natrium Na mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
75000Natriumoxid Na2O mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
13000Titan Ti mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
22000Titanoxid TiO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
500Arsenik As mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
1600Antimon Sb mg/kg Ts 15% EN 13656 mod. / ICP-MS a)
1700Barium Ba mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
< 2.6Berylium Be mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
3000Bly Pb mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
27Kobolt Co mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
1700Koppar Cu mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
480Krom Cr mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
27Molybden Mo mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
87Nickel Ni mg/kg Ts 35% EN 13656 mod. / ICP-MS a)
880Tenn Sn mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
67Vanadin mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
AR-15-SL-182554-01
EUSELI2-00291775
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11060365
Aska
2015-11-06
2015-11-12
Provtagare Sven Andersson
Provmärkning: Aska G
Analys Resultat Enhet Metod/refMäto.
23000Zink Zn mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
200Bor B mg/kg Ts 15% SS 028150-2 / ICP-AES a)*
0.51Kvicksilver Hg mg/kg Ts 25% SS 028150-2 / AFS a)*
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Mikael Sandin, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Karin Karlfeldt-Fedje ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-204186-01
EUSELI2-00297948
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11300220
Aska
2015-11-27
2015-12-11
Provtagare Sven Andersson
Provmärkning: Askrest G Tidigare 177-2015-11060367
Analys Resultat Enhet Metod/refMäto.
1.01Klor Cl % Ts 15% a)*SS 187185
49000Svavel S mg/kg Ts 25% a)*EN 13656 mod. / ICP-AES
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Lars Rosengren, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Karin Karlfeldt-Fedje ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 1
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v12
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-182556-01
EUSELI2-00291775
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11060367
Aska
2015-11-06
2015-11-12
Provtagare Sven Andersson
Provmärkning: Askrest G
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
a)
36.2Fukthalt % 10% EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
a)
50000Aluminium Al mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
95000Aluminiumoxid Al2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
9000Fosfor P mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
21000Fosforoxid P2O5 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
21000Järn Fe mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
31000Järnoxid Fe2O3 mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
120Kadmium Cd mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
190000Kalcium Ca mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
260000Kalciumoxid CaO mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
11000Kalium K mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
13000Kaliumoxid K2O mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
100000Kisel Si mg/kg Ts 20% EN 14385 / ICP-AES a)*
220000Kiseloxid SiO2 mg/kg Ts 30% EN 14385 a)*
14000Magnesium Mg mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
24000Magnesiumoxid MgO mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
860Mangan Mn mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
1400Manganoxid MnO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
11000Natrium Na mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
15000Natriumoxid Na2O mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
17000Titan Ti mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
28000Titanoxid TiO2 mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
730Arsenik As mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
2100Antimon Sb mg/kg Ts 15% EN 13656 mod. / ICP-MS a)
2000Barium Ba mg/kg Ts 30% EN 13656 mod. / ICP-AES a)
< 2.7Berylium Be mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
4600Bly Pb mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
38Kobolt Co mg/kg Ts 30% EN 13656 mod. / ICP-MS a)
2400Koppar Cu mg/kg Ts 20% EN 13656 mod. / ICP-AES a)
760Krom Cr mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
34Molybden Mo mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
140Nickel Ni mg/kg Ts 35% EN 13656 mod. / ICP-MS a)
1100Tenn Sn mg/kg Ts 20% EN 13656 mod. / ICP-MS a)
100Vanadin mg/kg Ts 25% EN 13656 mod. / ICP-MS a)
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
AR-15-SL-182556-01
EUSELI2-00291775
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11060367
Aska
2015-11-06
2015-11-12
Provtagare Sven Andersson
Provmärkning: Askrest G
Analys Resultat Enhet Metod/refMäto.
15000Zink Zn mg/kg Ts 25% EN 13656 mod. / ICP-AES a)
150Bor B mg/kg Ts 15% SS 028150-2 / ICP-AES a)*
3.7Kvicksilver Hg mg/kg Ts 25% SS 028150-2 / AFS a)*
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Mikael Sandin, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Karin Karlfeldt-Fedje ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v10
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-204187-01
EUSELI2-00297948
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11300221
Aska
2015-11-27
2015-12-11
Provtagare Sven Andersson
Provmärkning: Aska H
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning a)EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
2.8Fukthalt % 10% a)EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
11.65Klor Cl % Ts 15% a)*SS 187185
36000Aluminium Al mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
68000Aluminiumoxid Al2O3 mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
7200Fosfor P mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
16000Fosforoxid P2O5 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
15000Järn Fe mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
22000Järnoxid Fe2O3 mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
220Kadmium Cd mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
190000Kalcium Ca mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
260000Kalciumoxid CaO mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
53000Kalium K mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
64000Kaliumoxid K2O mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
57000Kisel Si mg/kg Ts 20% a)*EN 14385 / ICP-AES
120000Kiseloxid SiO2 mg/kg Ts 30% a)*EN 14385
13000Magnesium Mg mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
22000Magnesiumoxid MgO mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
720Mangan Mn mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
1100Manganoxid MnO2 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
55000Natrium Na mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
74000Natriumoxid Na2O mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
12000Titan Ti mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
20000Titanoxid TiO2 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
490Arsenik As mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
2000Antimon Sb mg/kg Ts 15% a)EN 13656 mod. / ICP-MS
1500Barium Ba mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
< 2.6Berylium Be mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
3400Bly Pb mg/kg Ts 20% a)EN 13656 mod. / ICP-MS
32Kobolt Co mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
1700Koppar Cu mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
470Krom Cr mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
27Molybden Mo mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
89Nickel Ni mg/kg Ts 35% a)EN 13656 mod. / ICP-MS
43000Svavel S mg/kg Ts 25% a)*EN 13656 mod. / ICP-AES
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v12
Denna rapport är elektroniskt signerad.
AR-15-SL-204187-01
EUSELI2-00297948
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11300221
Aska
2015-11-27
2015-12-11
Provtagare Sven Andersson
Provmärkning: Aska H
Analys Resultat Enhet Metod/refMäto.
940Tenn Sn mg/kg Ts 20% a)EN 13656 mod. / ICP-MS
81Vanadin mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
23000Zink Zn mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
230Bor B mg/kg Ts 15% a)*SS 028150-2 / ICP-AES
0.50Kvicksilver Hg mg/kg Ts 25% a)*SS 028150-2 / AFS
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Lars Rosengren, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Karin Karlfeldt-Fedje ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v12
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-204188-01
EUSELI2-00297948
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11300222
Aska
2015-11-27
2015-12-11
Provtagare Sven Andersson
Provmärkning: Askrest H
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning a)EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
38.9Fukthalt % 10% a)EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
1.70Klor Cl % Ts 15% a)*SS 187185
51000Aluminium Al mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
97000Aluminiumoxid Al2O3 mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
10000Fosfor P mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
23000Fosforoxid P2O5 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
21000Järn Fe mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
31000Järnoxid Fe2O3 mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
110Kadmium Cd mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
190000Kalcium Ca mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
270000Kalciumoxid CaO mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
13000Kalium K mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
15000Kaliumoxid K2O mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
98000Kisel Si mg/kg Ts 20% a)*EN 14385 / ICP-AES
210000Kiseloxid SiO2 mg/kg Ts 30% a)*EN 14385
13000Magnesium Mg mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
22000Magnesiumoxid MgO mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
850Mangan Mn mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
1300Manganoxid MnO2 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
12000Natrium Na mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
16000Natriumoxid Na2O mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
17000Titan Ti mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
28000Titanoxid TiO2 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
670Arsenik As mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
2500Antimon Sb mg/kg Ts 15% a)EN 13656 mod. / ICP-MS
600Barium Ba mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
< 2.8Berylium Be mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
5400Bly Pb mg/kg Ts 20% a)EN 13656 mod. / ICP-MS
36Kobolt Co mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
2500Koppar Cu mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
670Krom Cr mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
38Molybden Mo mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
140Nickel Ni mg/kg Ts 35% a)EN 13656 mod. / ICP-MS
57000Svavel S mg/kg Ts 25% a)*EN 13656 mod. / ICP-AES
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v12
Denna rapport är elektroniskt signerad.
AR-15-SL-204188-01
EUSELI2-00297948
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11300222
Aska
2015-11-27
2015-12-11
Provtagare Sven Andersson
Provmärkning: Askrest H
Analys Resultat Enhet Metod/refMäto.
1200Tenn Sn mg/kg Ts 20% a)EN 13656 mod. / ICP-MS
110Vanadin mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
14000Zink Zn mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
150Bor B mg/kg Ts 15% a)*SS 028150-2 / ICP-AES
3.7Kvicksilver Hg mg/kg Ts 25% a)*SS 028150-2 / AFS
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Lars Rosengren, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Karin Karlfeldt-Fedje ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v12
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-204189-01
EUSELI2-00297948
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11300223
Aska
2015-11-27
2015-12-11
Provtagare Sven Andersson
Provmärkning: Aska I
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning a)EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
0.8Fukthalt % 10% a)EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
11.67Klor Cl % Ts 15% a)*SS 187185
37000Aluminium Al mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
71000Aluminiumoxid Al2O3 mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
7200Fosfor P mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
17000Fosforoxid P2O5 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
16000Järn Fe mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
23000Järnoxid Fe2O3 mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
220Kadmium Cd mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
190000Kalcium Ca mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
270000Kalciumoxid CaO mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
52000Kalium K mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
63000Kaliumoxid K2O mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
66000Kisel Si mg/kg Ts 20% a)*EN 14385 / ICP-AES
140000Kiseloxid SiO2 mg/kg Ts 30% a)*EN 14385
13000Magnesium Mg mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
22000Magnesiumoxid MgO mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
730Mangan Mn mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
1200Manganoxid MnO2 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
54000Natrium Na mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
73000Natriumoxid Na2O mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
12000Titan Ti mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
20000Titanoxid TiO2 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
470Arsenik As mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
2000Antimon Sb mg/kg Ts 15% a)EN 13656 mod. / ICP-MS
1500Barium Ba mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
< 2.6Berylium Be mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
3500Bly Pb mg/kg Ts 20% a)EN 13656 mod. / ICP-MS
35Kobolt Co mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
1700Koppar Cu mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
460Krom Cr mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
27Molybden Mo mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
97Nickel Ni mg/kg Ts 35% a)EN 13656 mod. / ICP-MS
42000Svavel S mg/kg Ts 25% a)*EN 13656 mod. / ICP-AES
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v12
Denna rapport är elektroniskt signerad.
AR-15-SL-204189-01
EUSELI2-00297948
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11300223
Aska
2015-11-27
2015-12-11
Provtagare Sven Andersson
Provmärkning: Aska I
Analys Resultat Enhet Metod/refMäto.
910Tenn Sn mg/kg Ts 20% a)EN 13656 mod. / ICP-MS
84Vanadin mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
22000Zink Zn mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
190Bor B mg/kg Ts 15% a)*SS 028150-2 / ICP-AES
0.48Kvicksilver Hg mg/kg Ts 25% a)*SS 028150-2 / AFS
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Lars Rosengren, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Karin Karlfeldt-Fedje ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v12
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-204191-01
EUSELI2-00297948
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11300225
Aska
2015-11-27
2015-12-11
Provtagare Sven Andersson
Provmärkning: Askrest I
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning a)EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
31.8Fukthalt % 10% a)EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
0.35Klor Cl % Ts 15% a)*SS 187185
51000Aluminium Al mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
96000Aluminiumoxid Al2O3 mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
9500Fosfor P mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
22000Fosforoxid P2O5 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
21000Järn Fe mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
30000Järnoxid Fe2O3 mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
70Kadmium Cd mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
210000Kalcium Ca mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
290000Kalciumoxid CaO mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
8500Kalium K mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
10000Kaliumoxid K2O mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
91000Kisel Si mg/kg Ts 20% a)*EN 14385 / ICP-AES
190000Kiseloxid SiO2 mg/kg Ts 30% a)*EN 14385
15000Magnesium Mg mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
25000Magnesiumoxid MgO mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
910Mangan Mn mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
1400Manganoxid MnO2 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
8800Natrium Na mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
12000Natriumoxid Na2O mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
17000Titan Ti mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
28000Titanoxid TiO2 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
570Arsenik As mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
2500Antimon Sb mg/kg Ts 15% a)EN 13656 mod. / ICP-MS
1200Barium Ba mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
< 2.8Berylium Be mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
4600Bly Pb mg/kg Ts 20% a)EN 13656 mod. / ICP-MS
36Kobolt Co mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
2300Koppar Cu mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
630Krom Cr mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
34Molybden Mo mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
130Nickel Ni mg/kg Ts 35% a)EN 13656 mod. / ICP-MS
52000Svavel S mg/kg Ts 25% a)*EN 13656 mod. / ICP-AES
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v12
Denna rapport är elektroniskt signerad.
AR-15-SL-204191-01
EUSELI2-00297948
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11300225
Aska
2015-11-27
2015-12-11
Provtagare Sven Andersson
Provmärkning: Askrest I
Analys Resultat Enhet Metod/refMäto.
1200Tenn Sn mg/kg Ts 20% a)EN 13656 mod. / ICP-MS
110Vanadin mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
16000Zink Zn mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
160Bor B mg/kg Ts 15% a)*SS 028150-2 / ICP-AES
3.3Kvicksilver Hg mg/kg Ts 25% a)*SS 028150-2 / AFS
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Lars Rosengren, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Karin Karlfeldt-Fedje ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v12
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB
(Lidköping)
Box 887Sjöhagsg. 3SE-53119 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8390
AR-15-SL-202873-01
EUSELI2-00297261
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2015-11260677Provnummer: Ankomsttemp °CProvtagareProvtagningsdatum
17,2Sven Andersson2015-11-17
Provet ankom:
Övrigt förorenat vattenMatris:
2015-11-26
Utskriftsdatum: 2015-12-09
Provmärkning: Filtrat I
Provtagningsplats: 4197
Analys Resultat Enhet Metod/refMäto.
mg/l43000Klorid a)SS-EN ISO 10304-1:200910%
mg/l10000Natrium Na (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l9500Kalium K (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l7500Kalcium Ca (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
15%
mg/l0.65Järn Fe (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l6100Magnesium Mg (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l200Mangan Mn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l4.7Aluminium Al (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
15%
mg/l4.9Antimon, Sb (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
30%
mg/l0.35Arsenik As (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l2.0Barium Ba (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.00069Beryllium Be (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
35%
mg/l380Bly Pb (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 3
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v38
AR-15-SL-202873-01
EUSELI2-00297261
mg/l14Bor, B (uppsluten) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.60Fosfor P (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l350Kadmium Cd (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l420Kisel, Si (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
15%
mg/l0.24Kobolt Co (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l10.0Koppar Cu (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.051Krom Cr (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l8.1Litium, Li (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
25%
mg/l0.059Molybden, Mo (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.40Nickel Ni (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.026Selen, Se (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
35%
mg/l0.063Silver Ag (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l210Strontium, Sr (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l5600Svavel, S (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.18Tallium, Tl (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l0.21Tenn Sn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
µg/l< 50Titan, Ti (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.00023Uran U (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l0.095Vanadin V (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l2300Zink Zn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 3
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v38
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-204190-01
EUSELI2-00297948
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11300224
Aska
2015-11-27
2015-12-11
Provtagare Sven Andersson
Provmärkning: Aska J
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning a)EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
0.9Fukthalt % 10% a)EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
12.48Klor Cl % Ts 15% a)*SS 187185
34000Aluminium Al mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
64000Aluminiumoxid Al2O3 mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
6700Fosfor P mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
15000Fosforoxid P2O5 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
16000Järn Fe mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
23000Järnoxid Fe2O3 mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
260Kadmium Cd mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
180000Kalcium Ca mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
250000Kalciumoxid CaO mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
55000Kalium K mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
66000Kaliumoxid K2O mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
65000Kisel Si mg/kg Ts 20% a)*EN 14385 / ICP-AES
140000Kiseloxid SiO2 mg/kg Ts 30% a)*EN 14385
13000Magnesium Mg mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
21000Magnesiumoxid MgO mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
660Mangan Mn mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
1100Manganoxid MnO2 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
57000Natrium Na mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
77000Natriumoxid Na2O mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
12000Titan Ti mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
19000Titanoxid TiO2 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
510Arsenik As mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
1800Antimon Sb mg/kg Ts 15% a)EN 13656 mod. / ICP-MS
1400Barium Ba mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
< 2.6Berylium Be mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
4100Bly Pb mg/kg Ts 20% a)EN 13656 mod. / ICP-MS
28Kobolt Co mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
1800Koppar Cu mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
420Krom Cr mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
22Molybden Mo mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
90Nickel Ni mg/kg Ts 35% a)EN 13656 mod. / ICP-MS
39000Svavel S mg/kg Ts 25% a)*EN 13656 mod. / ICP-AES
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v12
Denna rapport är elektroniskt signerad.
AR-15-SL-204190-01
EUSELI2-00297948
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11300224
Aska
2015-11-27
2015-12-11
Provtagare Sven Andersson
Provmärkning: Aska J
Analys Resultat Enhet Metod/refMäto.
1100Tenn Sn mg/kg Ts 20% a)EN 13656 mod. / ICP-MS
59Vanadin mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
26000Zink Zn mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
240Bor B mg/kg Ts 15% a)*SS 028150-2 / ICP-AES
0.60Kvicksilver Hg mg/kg Ts 25% a)*SS 028150-2 / AFS
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Lars Rosengren, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Karin Karlfeldt-Fedje ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v12
Denna rapport är elektroniskt signerad.
Eurofins Environment Sweden AB (Lidköping)
Box 887
Sjöhagsg. 3
SE-53119 Lidköping
Tlf: +46 10 490 8110
Fax: +46 10 490 8390
AnalysrapportUppdragsmärkn.
Götaverken Miljö AB
Sven Andersson
Box 8876
402 72 GÖTEBORG
AR-15-SL-204192-01
EUSELI2-00297948
Kundnummer: SL8420465
4197
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11300226
Aska
2015-11-27
2015-12-11
Provtagare Sven Andersson
Provmärkning: Askrest J
Analys Resultat Enhet Metod/refMäto.
1.0Provberedning krossning, malning a)EN 14780:2011/EN 15443:2011/SS
187114:1992/SS 1871
33.8Fukthalt % 10% a)EN 14774-1,2,3:2009
mod/15414-1,2,3:2011 mod/SS187
0.33Klor Cl % Ts 15% a)*SS 187185
51000Aluminium Al mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
97000Aluminiumoxid Al2O3 mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
9600Fosfor P mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
22000Fosforoxid P2O5 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
24000Järn Fe mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
35000Järnoxid Fe2O3 mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
120Kadmium Cd mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
200000Kalcium Ca mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
290000Kalciumoxid CaO mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
10000Kalium K mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
12000Kaliumoxid K2O mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
110000Kisel Si mg/kg Ts 20% a)*EN 14385 / ICP-AES
230000Kiseloxid SiO2 mg/kg Ts 30% a)*EN 14385
14000Magnesium Mg mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
24000Magnesiumoxid MgO mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
840Mangan Mn mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
1300Manganoxid MnO2 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
10000Natrium Na mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
14000Natriumoxid Na2O mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
18000Titan Ti mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
30000Titanoxid TiO2 mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
760Arsenik As mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
2600Antimon Sb mg/kg Ts 15% a)EN 13656 mod. / ICP-MS
230Barium Ba mg/kg Ts 30% a)EN 13656 mod. / ICP-AES
< 2.8Berylium Be mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
5400Bly Pb mg/kg Ts 20% a)EN 13656 mod. / ICP-MS
37Kobolt Co mg/kg Ts 30% a)EN 13656 mod. / ICP-MS
2600Koppar Cu mg/kg Ts 20% a)EN 13656 mod. / ICP-AES
620Krom Cr mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
31Molybden Mo mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
120Nickel Ni mg/kg Ts 35% a)EN 13656 mod. / ICP-MS
56000Svavel S mg/kg Ts 25% a)*EN 13656 mod. / ICP-AES
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v12
Denna rapport är elektroniskt signerad.
AR-15-SL-204192-01
EUSELI2-00297948
Provbeskrivning:
Provnummer:
Provet ankom:
Matris:
Utskriftsdatum:
177-2015-11300226
Aska
2015-11-27
2015-12-11
Provtagare Sven Andersson
Provmärkning: Askrest J
Analys Resultat Enhet Metod/refMäto.
1400Tenn Sn mg/kg Ts 20% a)EN 13656 mod. / ICP-MS
87Vanadin mg/kg Ts 25% a)EN 13656 mod. / ICP-MS
20000Zink Zn mg/kg Ts 25% a)EN 13656 mod. / ICP-AES
190Bor B mg/kg Ts 15% a)*SS 028150-2 / ICP-AES
3.3Kvicksilver Hg mg/kg Ts 25% a)*SS 028150-2 / AFS
Utförande laboratorium/underleverantör:
a) Eurofins Environment Sweden AB (Lidköping), SWEDEN
Lars Rosengren, Rapportansvarig
Denna rapport är elektroniskt signerad.
Kopia till:
Karin Karlfeldt-Fedje ([email protected])
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför
Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till
det insända provet.Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-007v12
Denna rapport är elektroniskt signerad.
177-2015-11300227 177-2015-11300228
2015-11-27 2015-11-27Aska K Askrest K
Ämne EnhetProvberedning krossning, malning 1 1Fukthalt % 0,8 38,2Klor Cl % Ts 12,66 0,31Aluminium Al mg/kg Ts 36000 42000Aluminiumoxid Al2O3 mg/kg Ts 68000 80000Fosfor P mg/kg Ts 7000 8000Fosforoxid P2O5 mg/kg Ts 16000 18000Järn Fe mg/kg Ts 16000 18000Järnoxid Fe2O3 mg/kg Ts 23000 26000Kadmium Cd mg/kg Ts 270 61Kalcium Ca mg/kg Ts 180000 210000Kalciumoxid CaO mg/kg Ts 260000 300000Kalium K mg/kg Ts 58000 9000Kaliumoxid K2O mg/kg Ts 70000 11000Kisel Si mg/kg Ts 61000 88000Kiseloxid SiO2 mg/kg Ts 130000 190000Magnesium Mg mg/kg Ts 13000 12000Magnesiumoxid MgO mg/kg Ts 22000 20000Mangan Mn mg/kg Ts 670 700Manganoxid MnO2 mg/kg Ts 1100 1100Natrium Na mg/kg Ts 60000 8200Natriumoxid Na2O mg/kg Ts 80000 11000Titan Ti mg/kg Ts 13000 15000Titanoxid TiO2 mg/kg Ts 21000 26000Arsenik As mg/kg Ts 520 640Antimon Sb mg/kg Ts 1800 2300Barium Ba mg/kg Ts 1200 240Berylium Be mg/kg Ts < 2,6 < 2,9Bly Pb mg/kg Ts 4400 5100Kobolt Co mg/kg Ts 30 28Koppar Cu mg/kg Ts 1900 2400Krom Cr mg/kg Ts 430 510Molybden Mo mg/kg Ts 24 24Nickel Ni mg/kg Ts 94 120Svavel S mg/kg Ts 41000 81000Tenn Sn mg/kg Ts 1000 1300Vanadin mg/kg Ts 60 72Zink Zn mg/kg Ts 28000 15000Bor B mg/kg Ts 200 140Bor B mg/kg TsKvicksilver Hg mg/kg Ts 0,73 1,1
Eurofins Environment Sweden AB
(Lidköping)
Box 887Sjöhagsg. 3SE-53119 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8390
AR-15-SL-202865-01
EUSELI2-00297255
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2015-11260646Provnummer: Ankomsttemp °CProvtagareProvtagningsdatum
18,1Sven Andersson2015-11-18
Provet ankom:
Övrigt förorenat vattenMatris:
2015-11-26
Utskriftsdatum: 2015-12-09
Provmärkning: Filtrat K
Provtagningsplats: 4197
Analys Resultat Enhet Metod/refMäto.
mg/l33000Klorid a)SS-EN ISO 10304-1:200910%
mg/l15000Natrium Na (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l14000Kalium K (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l1100Kalcium Ca (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
15%
mg/l13Järn Fe (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l900Magnesium Mg (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l28Mangan Mn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l94Aluminium Al (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
15%
mg/l7.3Antimon, Sb (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
30%
mg/l1.4Arsenik As (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l0.65Barium Ba (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.0055Beryllium Be (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
35%
mg/l64Bly Pb (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 3
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v38
AR-15-SL-202865-01
EUSELI2-00297255
mg/l28Bor, B (uppsluten) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l3.3Fosfor P (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l65Kadmium Cd (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l51Kisel, Si (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
15%
mg/l0.75Kobolt Co (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l5.2Koppar Cu (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.33Krom Cr (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
25%
mg/l8.3Litium, Li (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
25%
mg/l0.21Molybden, Mo (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l1.3Nickel Ni (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.028Selen, Se (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
35%
mg/l0.048Silver Ag (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l6.1Strontium, Sr (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l3800Svavel, S (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.10Tallium, Tl (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l0.94Tenn Sn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
µg/l1100Titan, Ti (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
mg/l0.0020Uran U (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
20%
mg/l0.33Vanadin V (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 17294-2 utg1 mod
30%
mg/l4300Zink Zn (uppslutet) a)SS-EN ISO 15587:2009 /SS-EN ISO 11885 utg2 mod
20%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 3
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v38
Eurofins Environment Testing Sweden AB
Box 887513 19 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-018993-01
EUSELI2-00310812
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-02030537Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-01-26
Provet ankom:
Övrigt fast materialMatris:
2016-01-29
Utskriftsdatum: 2016-02-12
Provmärkning: F1B Kaka
Analys Resultat Enhet Metod/refMäto.
%73.9Fukthalt a)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
% Ts23.77Klor Cl a)*SS 18718515%
mg/kg Ts310Aluminium Al a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts580Aluminiumoxid Al2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts380Fosfor P a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts880Fosforoxid P2O5 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts210Järn Fe a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts300Järnoxid Fe2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1500Kadmium Cd a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts38000Kalcium Ca a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts54000Kalciumoxid CaO a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts40000Kalium K a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts48000Kaliumoxid K2O a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts5500Kisel Si a)*EN 14385 / ICP-AES20%
mg/kg Ts12000Kiseloxid SiO2 a)*EN 1438530%
mg/kg Ts45000Magnesium Mg a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts74000Magnesiumoxid MgO a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts3000Mangan Mn a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts4700Manganoxid MnO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts58000Natrium Na a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts78000Natriumoxid Na2O a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts110Titan Ti a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts190Titanoxid TiO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts51Arsenik As a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts440Antimon Sb a)*EN 13656 mod. / ICP-MS15%
mg/kg Ts< 55Barium Ba a)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-018993-01
EUSELI2-00310812
mg/kg Ts< 2.8Berylium Be a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts5500Bly Pb a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts76Kobolt Co a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts360Koppar Cu a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts9.4Krom Cr a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts< 22Molybden Mo a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts72Nickel Ni a)*EN 13656 mod. / ICP-MS35%
mg/kg Ts15Tenn Sn a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts< 2.8Vanadin a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts320000Zink Zn a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts400Bor B a)*SS 028150-2 / ICP-AES15%
mg/kg Ts0.41Kvicksilver Hg a)*SS 028150-2 / AFS25%
Utförande laboratorium/underleverantör:
a) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected]) ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 887513 19 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-018994-01
EUSELI2-00310812
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-02030538Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-01-26
Provet ankom:
Övrigt fast materialMatris:
2016-01-29
Utskriftsdatum: 2016-02-12
Provmärkning: F2B Kaka
Analys Resultat Enhet Metod/refMäto.
%72.8Fukthalt a)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
% Ts20.66Klor Cl a)*SS 18718515%
mg/kg Ts190Aluminium Al a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts370Aluminiumoxid Al2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts350Fosfor P a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts790Fosforoxid P2O5 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts280Järn Fe a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts410Järnoxid Fe2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1500Kadmium Cd a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts34000Kalcium Ca a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts48000Kalciumoxid CaO a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts39000Kalium K a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts47000Kaliumoxid K2O a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts5900Kisel Si a)*EN 14385 / ICP-AES20%
mg/kg Ts13000Kiseloxid SiO2 a)*EN 1438530%
mg/kg Ts46000Magnesium Mg a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts75000Magnesiumoxid MgO a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts2900Mangan Mn a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts4600Manganoxid MnO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts57000Natrium Na a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts77000Natriumoxid Na2O a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts38Titan Ti a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts64Titanoxid TiO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts18Arsenik As a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts410Antimon Sb a)*EN 13656 mod. / ICP-MS15%
mg/kg Ts< 56Barium Ba a)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-018994-01
EUSELI2-00310812
mg/kg Ts< 2.8Berylium Be a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts4800Bly Pb a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts68Kobolt Co a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts350Koppar Cu a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts15Krom Cr a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts< 23Molybden Mo a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts49Nickel Ni a)*EN 13656 mod. / ICP-MS35%
mg/kg Ts6.2Tenn Sn a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts< 2.8Vanadin a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts310000Zink Zn a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts400Bor B a)*SS 028150-2 / ICP-AES15%
mg/kg Ts0.36Kvicksilver Hg a)*SS 028150-2 / AFS25%
Utförande laboratorium/underleverantör:
a) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected]) ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 887513 19 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-018995-01
EUSELI2-00310812
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-02030539Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-01-27
Provet ankom:
Övrigt fast materialMatris:
2016-01-29
Utskriftsdatum: 2016-02-12
Provmärkning: F3A Kaka
Analys Resultat Enhet Metod/refMäto.
%80.9Fukthalt a)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
% Ts8.19Klor Cl a)*SS 18718515%
mg/kg Ts170Aluminium Al a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts330Aluminiumoxid Al2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts400Fosfor P a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts930Fosforoxid P2O5 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts120Järn Fe a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts170Järnoxid Fe2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts2800Kadmium Cd a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts22000Kalcium Ca a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts31000Kalciumoxid CaO a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts12000Kalium K a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts15000Kaliumoxid K2O a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts4500Kisel Si a)*EN 14385 / ICP-AES20%
mg/kg Ts9700Kiseloxid SiO2 a)*EN 1438530%
mg/kg Ts73000Magnesium Mg a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts120000Magnesiumoxid MgO a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts3700Mangan Mn a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts5800Manganoxid MnO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts18000Natrium Na a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts24000Natriumoxid Na2O a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts31Titan Ti a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts52Titanoxid TiO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts37Arsenik As a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts440Antimon Sb a)*EN 13656 mod. / ICP-MS15%
mg/kg Ts< 56Barium Ba a)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-018995-01
EUSELI2-00310812
mg/kg Ts< 2.8Berylium Be a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts4300Bly Pb a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts87Kobolt Co a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts520Koppar Cu a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts3.5Krom Cr a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts< 23Molybden Mo a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts56Nickel Ni a)*EN 13656 mod. / ICP-MS35%
mg/kg Ts5.5Tenn Sn a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts< 2.8Vanadin a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts420000Zink Zn a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts460Bor B a)*SS 028150-2 / ICP-AES15%
mg/kg Ts0.63Kvicksilver Hg a)*SS 028150-2 / AFS25%
Utförande laboratorium/underleverantör:
a) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected]) ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 887513 19 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-018996-01
EUSELI2-00310812
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-02030540Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-01-27
Provet ankom:
Övrigt fast materialMatris:
2016-01-29
Utskriftsdatum: 2016-02-12
Provmärkning: F4A Kaka
Analys Resultat Enhet Metod/refMäto.
%73.9Fukthalt a)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
% Ts20.96Klor Cl a)*SS 18718515%
mg/kg Ts260Aluminium Al a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts490Aluminiumoxid Al2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts310Fosfor P a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts710Fosforoxid P2O5 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts370Järn Fe a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts530Järnoxid Fe2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts2000Kadmium Cd a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts34000Kalcium Ca a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts47000Kalciumoxid CaO a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts34000Kalium K a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts41000Kaliumoxid K2O a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts6700Kisel Si a)*EN 14385 / ICP-AES20%
mg/kg Ts14000Kiseloxid SiO2 a)*EN 1438530%
mg/kg Ts50000Magnesium Mg a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts84000Magnesiumoxid MgO a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts2300Mangan Mn a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts3700Manganoxid MnO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts63000Natrium Na a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts85000Natriumoxid Na2O a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts35Titan Ti a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts58Titanoxid TiO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts22Arsenik As a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts280Antimon Sb a)*EN 13656 mod. / ICP-MS15%
mg/kg Ts< 55Barium Ba a)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-018996-01
EUSELI2-00310812
mg/kg Ts< 2.8Berylium Be a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts2800Bly Pb a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts56Kobolt Co a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts340Koppar Cu a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts28Krom Cr a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts< 22Molybden Mo a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts39Nickel Ni a)*EN 13656 mod. / ICP-MS35%
mg/kg Ts4.4Tenn Sn a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts< 2.8Vanadin a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts260000Zink Zn a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts430Bor B a)*SS 028150-2 / ICP-AES15%
mg/kg Ts0.13Kvicksilver Hg a)*SS 028150-2 / AFS25%
Utförande laboratorium/underleverantör:
a) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected]) ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 887513 19 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-018997-01
EUSELI2-00310812
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-02030541Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-01-27
Provet ankom:
Övrigt fast materialMatris:
2016-01-29
Utskriftsdatum: 2016-02-12
Provmärkning: F5AS Kaka
Analys Resultat Enhet Metod/refMäto.
%78.1Fukthalt a)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
% Ts12.28Klor Cl a)*SS 18718515%
mg/kg Ts790Aluminium Al a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1500Aluminiumoxid Al2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts590Fosfor P a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts1400Fosforoxid P2O5 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts390Järn Fe a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts550Järnoxid Fe2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts4100Kadmium Cd a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts47000Kalcium Ca a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts66000Kalciumoxid CaO a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts29000Kalium K a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts35000Kaliumoxid K2O a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts14000Kisel Si a)*EN 14385 / ICP-AES20%
mg/kg Ts29000Kiseloxid SiO2 a)*EN 1438530%
mg/kg Ts86000Magnesium Mg a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts140000Magnesiumoxid MgO a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts2800Mangan Mn a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts4500Manganoxid MnO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts42000Natrium Na a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts57000Natriumoxid Na2O a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts240Titan Ti a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts400Titanoxid TiO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts320Arsenik As a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts610Antimon Sb a)*EN 13656 mod. / ICP-MS15%
mg/kg Ts400Barium Ba a)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-018997-01
EUSELI2-00310812
mg/kg Ts< 2.9Berylium Be a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts3800Bly Pb a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts66Kobolt Co a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts460Koppar Cu a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts35Krom Cr a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts< 23Molybden Mo a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts45Nickel Ni a)*EN 13656 mod. / ICP-MS35%
mg/kg Ts87Tenn Sn a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts9.2Vanadin a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts300000Zink Zn a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts250Bor B a)*SS 028150-2 / ICP-AES15%
mg/kg Ts0.46Kvicksilver Hg a)*SS 028150-2 / AFS25%
Utförande laboratorium/underleverantör:
a) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected]) ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 887513 19 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-018998-01
EUSELI2-00310812
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-02030542Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-01-28
Provet ankom:
Övrigt fast materialMatris:
2016-01-29
Utskriftsdatum: 2016-02-12
Provmärkning: F6CS Kaka
Analys Resultat Enhet Metod/refMäto.
%77.3Fukthalt a)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
% Ts2.80Klor Cl a)*SS 18718515%
mg/kg Ts600Aluminium Al a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1100Aluminiumoxid Al2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts600Fosfor P a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts1400Fosforoxid P2O5 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts350Järn Fe a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts500Järnoxid Fe2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts2000Kadmium Cd a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts14000Kalcium Ca a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts19000Kalciumoxid CaO a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts1900Kalium K a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts2300Kaliumoxid K2O a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts11000Kisel Si a)*EN 14385 / ICP-AES20%
mg/kg Ts24000Kiseloxid SiO2 a)*EN 1438530%
mg/kg Ts41000Magnesium Mg a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts69000Magnesiumoxid MgO a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts4100Mangan Mn a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts6400Manganoxid MnO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts14000Natrium Na a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts18000Natriumoxid Na2O a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts210Titan Ti a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts340Titanoxid TiO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts180Arsenik As a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts640Antimon Sb a)*EN 13656 mod. / ICP-MS15%
mg/kg Ts150Barium Ba a)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-018998-01
EUSELI2-00310812
mg/kg Ts< 2.8Berylium Be a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts3900Bly Pb a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts98Kobolt Co a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts460Koppar Cu a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts23Krom Cr a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts< 23Molybden Mo a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts61Nickel Ni a)*EN 13656 mod. / ICP-MS35%
mg/kg Ts56Tenn Sn a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts4.5Vanadin a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts480000Zink Zn a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts340Bor B a)*SS 028150-2 / ICP-AES15%
mg/kg Ts1.0Kvicksilver Hg a)*SS 028150-2 / AFS25%
Utförande laboratorium/underleverantör:
a) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected]) ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 887513 19 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-018999-01
EUSELI2-00310812
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-02030543Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-01-28
Provet ankom:
Övrigt fast materialMatris:
2016-01-29
Utskriftsdatum: 2016-02-12
Provmärkning: F7CS Kaka
Analys Resultat Enhet Metod/refMäto.
%78.8Fukthalt a)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
% Ts8.81Klor Cl a)*SS 18718515%
mg/kg Ts540Aluminium Al a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1000Aluminiumoxid Al2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts580Fosfor P a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts1300Fosforoxid P2O5 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts380Järn Fe a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts540Järnoxid Fe2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts2500Kadmium Cd a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts22000Kalcium Ca a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts30000Kalciumoxid CaO a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts13000Kalium K a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts16000Kaliumoxid K2O a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts12000Kisel Si a)*EN 14385 / ICP-AES20%
mg/kg Ts26000Kiseloxid SiO2 a)*EN 1438530%
mg/kg Ts54000Magnesium Mg a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts89000Magnesiumoxid MgO a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts3600Mangan Mn a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts5700Manganoxid MnO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts27000Natrium Na a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts37000Natriumoxid Na2O a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts200Titan Ti a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts330Titanoxid TiO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts210Arsenik As a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts590Antimon Sb a)*EN 13656 mod. / ICP-MS15%
mg/kg Ts250Barium Ba a)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-018999-01
EUSELI2-00310812
mg/kg Ts< 2.8Berylium Be a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts3700Bly Pb a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts84Kobolt Co a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts400Koppar Cu a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts26Krom Cr a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts< 23Molybden Mo a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts53Nickel Ni a)*EN 13656 mod. / ICP-MS35%
mg/kg Ts67Tenn Sn a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts5.8Vanadin a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts420000Zink Zn a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts480Bor B a)*SS 028150-2 / ICP-AES15%
mg/kg Ts0.20Kvicksilver Hg a)*SS 028150-2 / AFS25%
Utförande laboratorium/underleverantör:
a) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected]) ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 887513 19 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-019000-01
EUSELI2-00310812
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-02030544Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-01-28
Provet ankom:
Övrigt fast materialMatris:
2016-01-29
Utskriftsdatum: 2016-02-12
Provmärkning: F8K Kaka
Analys Resultat Enhet Metod/refMäto.
%77.7Fukthalt a)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
% Ts9.93Klor Cl a)*SS 18718515%
mg/kg Ts6100Aluminium Al a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts12000Aluminiumoxid Al2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts470Fosfor P a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts1100Fosforoxid P2O5 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts1100Järn Fe a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1600Järnoxid Fe2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts4400Kadmium Cd a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts22000Kalcium Ca a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts31000Kalciumoxid CaO a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts35000Kalium K a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts42000Kaliumoxid K2O a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts11000Kisel Si a)*EN 14385 / ICP-AES20%
mg/kg Ts24000Kiseloxid SiO2 a)*EN 1438530%
mg/kg Ts66000Magnesium Mg a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts110000Magnesiumoxid MgO a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts2400Mangan Mn a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts3700Manganoxid MnO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts51000Natrium Na a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts68000Natriumoxid Na2O a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts45Titan Ti a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts75Titanoxid TiO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts21Arsenik As a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts140Antimon Sb a)*EN 13656 mod. / ICP-MS15%
mg/kg Ts< 58Barium Ba a)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-019000-01
EUSELI2-00310812
mg/kg Ts< 2.9Berylium Be a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts3900Bly Pb a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts71Kobolt Co a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts370Koppar Cu a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts18Krom Cr a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts< 23Molybden Mo a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts130Nickel Ni a)*EN 13656 mod. / ICP-MS35%
mg/kg Ts5.5Tenn Sn a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts8.1Vanadin a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts320000Zink Zn a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts710Bor B a)*SS 028150-2 / ICP-AES15%
mg/kg Ts0.085Kvicksilver Hg a)*SS 028150-2 / AFS25%
Utförande laboratorium/underleverantör:
a) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected]) ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 887513 19 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-019001-01
EUSELI2-00310812
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-02030545Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-01-28
Provet ankom:
Övrigt fast materialMatris:
2016-01-29
Utskriftsdatum: 2016-02-12
Provmärkning: F9K Kaka
Analys Resultat Enhet Metod/refMäto.
%80.8Fukthalt a)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
% Ts7.56Klor Cl a)*SS 18718515%
mg/kg Ts6100Aluminium Al a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts12000Aluminiumoxid Al2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts370Fosfor P a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts840Fosforoxid P2O5 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts190Järn Fe a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts270Järnoxid Fe2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts4900Kadmium Cd a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts20000Kalcium Ca a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts28000Kalciumoxid CaO a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts26000Kalium K a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts31000Kaliumoxid K2O a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts11000Kisel Si a)*EN 14385 / ICP-AES20%
mg/kg Ts24000Kiseloxid SiO2 a)*EN 1438530%
mg/kg Ts72000Magnesium Mg a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts120000Magnesiumoxid MgO a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts2400Mangan Mn a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts3800Manganoxid MnO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts37000Natrium Na a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts50000Natriumoxid Na2O a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts24Titan Ti a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts41Titanoxid TiO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts24Arsenik As a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts160Antimon Sb a)*EN 13656 mod. / ICP-MS15%
mg/kg Ts< 57Barium Ba a)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-019001-01
EUSELI2-00310812
mg/kg Ts< 2.9Berylium Be a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts4400Bly Pb a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts79Kobolt Co a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts420Koppar Cu a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts11Krom Cr a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts< 23Molybden Mo a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts140Nickel Ni a)*EN 13656 mod. / ICP-MS35%
mg/kg Ts4.7Tenn Sn a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts7.1Vanadin a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts360000Zink Zn a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts640Bor B a)*SS 028150-2 / ICP-AES15%
mg/kg Ts0.10Kvicksilver Hg a)*SS 028150-2 / AFS25%
Utförande laboratorium/underleverantör:
a) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected]) ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 887513 19 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-019002-01
EUSELI2-00310812
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-02030546Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-01-29
Provet ankom:
Övrigt fast materialMatris:
2016-01-29
Utskriftsdatum: 2016-02-12
Provmärkning: F10l Kaka
Analys Resultat Enhet Metod/refMäto.
%79.1Fukthalt a)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
% Ts9.89Klor Cl a)*SS 18718515%
mg/kg Ts310Aluminium Al a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts580Aluminiumoxid Al2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts360Fosfor P a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts830Fosforoxid P2O5 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts< 120Järn Fe a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts<170Järnoxid Fe2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts3700Kadmium Cd a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts27000Kalcium Ca a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts38000Kalciumoxid CaO a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts12000Kalium K a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts15000Kaliumoxid K2O a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts8400Kisel Si a)*EN 14385 / ICP-AES20%
mg/kg Ts18000Kiseloxid SiO2 a)*EN 1438530%
mg/kg Ts74000Magnesium Mg a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts120000Magnesiumoxid MgO a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts3400Mangan Mn a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts5400Manganoxid MnO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts21000Natrium Na a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts29000Natriumoxid Na2O a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts< 23Titan Ti a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts<38Titanoxid TiO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts12Arsenik As a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts670Antimon Sb a)*EN 13656 mod. / ICP-MS15%
mg/kg Ts< 57Barium Ba a)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-019002-01
EUSELI2-00310812
mg/kg Ts< 2.9Berylium Be a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts6100Bly Pb a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts100Kobolt Co a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts1500Koppar Cu a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts< 2.9Krom Cr a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts< 23Molybden Mo a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts160Nickel Ni a)*EN 13656 mod. / ICP-MS35%
mg/kg Ts3.5Tenn Sn a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts< 2.9Vanadin a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts380000Zink Zn a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts390Bor B a)*SS 028150-2 / ICP-AES15%
mg/kg Ts0.055Kvicksilver Hg a)*SS 028150-2 / AFS25%
Utförande laboratorium/underleverantör:
a) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected]) ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 887513 19 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-019800-01
EUSELI2-00310816
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-02030553Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-01-29
Provet ankom:
Övrigt fast materialMatris:
2016-02-01
Utskriftsdatum: 2016-02-15
Provmärkning: F11D Kaka
Analys Resultat Enhet Metod/refMäto.
%83.4Fukthalt a)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
% Ts7.80Klor Cl a)*SS 18718515%
mg/kg Ts5100Aluminium Al a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts9600Aluminiumoxid Al2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts540Fosfor P a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts1200Fosforoxid P2O5 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts< 150Järn Fe a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts<210Järnoxid Fe2O3 a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts2800Kadmium Cd a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts6600Kalcium Ca a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts9300Kalciumoxid CaO a)*EN 13656 mod. / ICP-AES30%
mg/kg Ts18000Kalium K a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts21000Kaliumoxid K2O a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts15000Kisel Si a)*EN 14385 / ICP-AES20%
mg/kg Ts32000Kiseloxid SiO2 a)*EN 1438530%
mg/kg Ts37000Magnesium Mg a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts62000Magnesiumoxid MgO a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts2600Mangan Mn a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts4100Manganoxid MnO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts51000Natrium Na a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts68000Natriumoxid Na2O a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts56Titan Ti a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts93Titanoxid TiO2 a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts320Arsenik As a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts390Antimon Sb a)*EN 13656 mod. / ICP-MS15%
mg/kg Ts< 74Barium Ba a)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-019800-01
EUSELI2-00310816
mg/kg Ts< 3.7Berylium Be a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts3600Bly Pb a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts71Kobolt Co a)*EN 13656 mod. / ICP-MS30%
mg/kg Ts1500Koppar Cu a)*EN 13656 mod. / ICP-AES20%
mg/kg Ts18Krom Cr a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts< 30Molybden Mo a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts98Nickel Ni a)*EN 13656 mod. / ICP-MS35%
mg/kg Ts10Tenn Sn a)*EN 13656 mod. / ICP-MS20%
mg/kg Ts13Vanadin a)*EN 13656 mod. / ICP-MS25%
mg/kg Ts340000Zink Zn a)*EN 13656 mod. / ICP-AES25%
mg/kg Ts370Bor B a)*SS 028150-2 / ICP-AES15%
mg/kg Ts< 0.066Kvicksilver Hg a)*SS 028150-2 / AFS25%
Utförande laboratorium/underleverantör:
a) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected]) ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 737531 17 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-040365-01
EUSELI2-00319331
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-03090337Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-02-29
Provet ankom:
Övrigt fast materialMatris:
2016-03-07
Utskriftsdatum: 2016-03-22
Provmärkning: F12CS10.5P Kaka
Provtagningsplats: 4197
Analys Resultat Enhet Metod/refMäto.
%77.8Fukthalt b)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
mg/kg Ts7300Aluminium Al b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts14000Aluminiumoxid Al2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1900Fosfor P b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts4400Fosforoxid P2O5 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts3100Järn Fe b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts4500Järnoxid Fe2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts3300Kadmium Cd b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts53000Kalcium Ca b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts75000Kalciumoxid CaO b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts21000Kalium K b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts25000Kaliumoxid K2O b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts36000Kisel Si b)*EN 14385 / ICP-AES20%
mg/kg Ts77000Kiseloxid SiO2 b)*EN 1438530%
mg/kg Ts68000Magnesium Mg b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts110000Magnesiumoxid MgO b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts2600Mangan Mn b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts4200Manganoxid MnO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts30000Natrium Na b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts41000Natriumoxid Na2O b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts2100Titan Ti b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts3400Titanoxid TiO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts740Arsenik As b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts1000Antimon Sb b)*EN 13656 mod. / ICP-MS15%
mg/kg Ts850Barium Ba b)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-040365-01
EUSELI2-00319331
mg/kg Ts< 2.9Berylium Be b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts5100Bly Pb b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts69Kobolt Co b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts760Koppar Cu b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts170Krom Cr b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts< 23Molybden Mo b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts70Nickel Ni b)*EN 13656 mod. / ICP-MS35%
mg/kg Ts330Tenn Sn b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts29Vanadin b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts370000Zink Zn b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts290Bor B b)*SS 028150-2 / ICP-AES15%
mg/kg Ts0.97Kvicksilver Hg b)*SS 028150-2 / AFS25%
% Ts37Klorid b)*
g/100 g8.31Klorid a)*Silvernitrattitrering
Utförande laboratorium/underleverantör:
a) Eurofins Food & Feed Testing Sweden (Lidköping), SWEDENb) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected])Karin Karlfeldt ([email protected])Sven Brantebäck ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 737531 17 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-040366-01
EUSELI2-00319331
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-03090338Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-02-29
Provet ankom:
Övrigt fast materialMatris:
2016-03-07
Utskriftsdatum: 2016-03-22
Provmärkning: F13CS8P kaka
Provtagningsplats: 4197
Analys Resultat Enhet Metod/refMäto.
%76.3Fukthalt b)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
mg/kg Ts10000Aluminium Al b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts19000Aluminiumoxid Al2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts2300Fosfor P b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts5300Fosforoxid P2O5 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts6100Järn Fe b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts8800Järnoxid Fe2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1400Kadmium Cd b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts54000Kalcium Ca b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts75000Kalciumoxid CaO b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts26000Kalium K b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts32000Kaliumoxid K2O b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts48000Kisel Si b)*EN 14385 / ICP-AES20%
mg/kg Ts100000Kiseloxid SiO2 b)*EN 1438530%
mg/kg Ts61000Magnesium Mg b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts100000Magnesiumoxid MgO b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts3100Mangan Mn b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts4900Manganoxid MnO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts35000Natrium Na b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts47000Natriumoxid Na2O b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts2600Titan Ti b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts4300Titanoxid TiO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts930Arsenik As b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts1200Antimon Sb b)*EN 13656 mod. / ICP-MS15%
mg/kg Ts1100Barium Ba b)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-040366-01
EUSELI2-00319331
mg/kg Ts< 3.5Berylium Be b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts5900Bly Pb b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts73Kobolt Co b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts860Koppar Cu b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts180Krom Cr b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts< 28Molybden Mo b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts65Nickel Ni b)*EN 13656 mod. / ICP-MS35%
mg/kg Ts400Tenn Sn b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts33Vanadin b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts380000Zink Zn b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts790Bor B b)*SS 028150-2 / ICP-AES15%
mg/kg Ts1.7Kvicksilver Hg b)*SS 028150-2 / AFS25%
% Ts35Klorid b)*
g/100 g8.40Klorid a)*Silvernitrattitrering
Utförande laboratorium/underleverantör:
a) Eurofins Food & Feed Testing Sweden (Lidköping), SWEDENb) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected])Karin Karlfeldt ([email protected])Sven Brantebäck ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 737531 17 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-040360-01
EUSELI2-00319331
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-03090332Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-03-01
Provet ankom:
Övrigt fast materialMatris:
2016-03-07
Utskriftsdatum: 2016-03-22
Provmärkning: Kaka F14DS9.25
Provtagningsplats: 4197
Analys Resultat Enhet Metod/refMäto.
%79.9Fukthalt b)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
mg/kg Ts8700Aluminium Al b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts16000Aluminiumoxid Al2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1200Fosfor P b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts2800Fosforoxid P2O5 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts1000Järn Fe b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1500Järnoxid Fe2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts4100Kadmium Cd b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts15000Kalcium Ca b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts21000Kalciumoxid CaO b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts11000Kalium K b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts14000Kaliumoxid K2O b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts48000Kisel Si b)*EN 14385 / ICP-AES20%
mg/kg Ts100000Kiseloxid SiO2 b)*EN 1438530%
mg/kg Ts52000Magnesium Mg b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts86000Magnesiumoxid MgO b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts3100Mangan Mn b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts4900Manganoxid MnO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts20000Natrium Na b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts27000Natriumoxid Na2O b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts490Titan Ti b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts810Titanoxid TiO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts720Arsenik As b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts2100Antimon Sb b)*EN 13656 mod. / ICP-MS15%
mg/kg Ts210Barium Ba b)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-040360-01
EUSELI2-00319331
mg/kg Ts< 2.9Berylium Be b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts7900Bly Pb b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts110Kobolt Co b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts1700Koppar Cu b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts100Krom Cr b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts25Molybden Mo b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts160Nickel Ni b)*EN 13656 mod. / ICP-MS35%
mg/kg Ts240Tenn Sn b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts48Vanadin b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts400000Zink Zn b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts320Bor B b)*SS 028150-2 / ICP-AES15%
mg/kg Ts1.0Kvicksilver Hg b)*SS 028150-2 / AFS25%
% Ts17Klorid b)*
g/100 g3.46Klorid a)*Silvernitrattitrering
Utförande laboratorium/underleverantör:
a) Eurofins Food & Feed Testing Sweden (Lidköping), SWEDENb) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected])Karin Karlfeldt ([email protected])Sven Brantebäck ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 737531 17 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-040361-01
EUSELI2-00319331
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-03090333Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-03-01
Provet ankom:
Övrigt fast materialMatris:
2016-03-07
Utskriftsdatum: 2016-03-22
Provmärkning: Kaka F15S9.25P
Provtagningsplats: 4197
Analys Resultat Enhet Metod/refMäto.
%79.9Fukthalt b)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
mg/kg Ts14000Aluminium Al b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts26000Aluminiumoxid Al2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1500Fosfor P b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts3500Fosforoxid P2O5 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts2900Järn Fe b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts4200Järnoxid Fe2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts3700Kadmium Cd b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts18000Kalcium Ca b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts26000Kalciumoxid CaO b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts4800Kalium K b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts5800Kaliumoxid K2O b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts66000Kisel Si b)*EN 14385 / ICP-AES20%
mg/kg Ts140000Kiseloxid SiO2 b)*EN 1438530%
mg/kg Ts46000Magnesium Mg b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts76000Magnesiumoxid MgO b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts3100Mangan Mn b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts4900Manganoxid MnO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts7100Natrium Na b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts9500Natriumoxid Na2O b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts1300Titan Ti b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts2100Titanoxid TiO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts670Arsenik As b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts1800Antimon Sb b)*EN 13656 mod. / ICP-MS15%
mg/kg Ts290Barium Ba b)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-040361-01
EUSELI2-00319331
mg/kg Ts< 3.1Berylium Be b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts8900Bly Pb b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts86Kobolt Co b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts1900Koppar Cu b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts130Krom Cr b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts31Molybden Mo b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts130Nickel Ni b)*EN 13656 mod. / ICP-MS35%
mg/kg Ts300Tenn Sn b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts48Vanadin b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts450000Zink Zn b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts220Bor B b)*SS 028150-2 / ICP-AES15%
mg/kg Ts2.1Kvicksilver Hg b)*SS 028150-2 / AFS25%
% Ts5.0Klorid b)*
g/100 g1.00Klorid a)*Silvernitrattitrering
Utförande laboratorium/underleverantör:
a) Eurofins Food & Feed Testing Sweden (Lidköping), SWEDENb) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected])Karin Karlfeldt ([email protected])Sven Brantebäck ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 737531 17 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-040362-01
EUSELI2-00319331
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-03090334Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-03-01
Provet ankom:
Övrigt fast materialMatris:
2016-03-07
Utskriftsdatum: 2016-03-22
Provmärkning: Kaka F16DS7
Provtagningsplats: 4197
Analys Resultat Enhet Metod/refMäto.
%73.4Fukthalt b)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
mg/kg Ts15000Aluminium Al b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts28000Aluminiumoxid Al2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1300Fosfor P b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts3000Fosforoxid P2O5 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts1800Järn Fe b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts2500Järnoxid Fe2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts830Kadmium Cd b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts10000Kalcium Ca b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts14000Kalciumoxid CaO b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts6500Kalium K b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts7900Kaliumoxid K2O b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts77000Kisel Si b)*EN 14385 / ICP-AES20%
mg/kg Ts160000Kiseloxid SiO2 b)*EN 1438530%
mg/kg Ts4600Magnesium Mg b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts7600Magnesiumoxid MgO b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1100Mangan Mn b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts1700Manganoxid MnO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts3400Natrium Na b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts4600Natriumoxid Na2O b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts860Titan Ti b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts1400Titanoxid TiO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts870Arsenik As b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts2800Antimon Sb b)*EN 13656 mod. / ICP-MS15%
mg/kg Ts380Barium Ba b)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-040362-01
EUSELI2-00319331
mg/kg Ts< 3.1Berylium Be b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts13000Bly Pb b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts63Kobolt Co b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts2300Koppar Cu b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts200Krom Cr b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts74Molybden Mo b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts100Nickel Ni b)*EN 13656 mod. / ICP-MS35%
mg/kg Ts350Tenn Sn b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts65Vanadin b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts500000Zink Zn b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts48Bor B b)*SS 028150-2 / ICP-AES15%
mg/kg Ts0.82Kvicksilver Hg b)*SS 028150-2 / AFS25%
% Ts0.98Klorid b)*
g/100 g0.26Klorid a)*Silvernitrattitrering
Utförande laboratorium/underleverantör:
a) Eurofins Food & Feed Testing Sweden (Lidköping), SWEDENb) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected])Karin Karlfeldt ([email protected])Sven Brantebäck ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 737531 17 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-040363-01
EUSELI2-00319331
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-03090335Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-03-01
Provet ankom:
Övrigt fast materialMatris:
2016-03-07
Utskriftsdatum: 2016-03-22
Provmärkning: Kaka F17DS8
Provtagningsplats: 4197
Analys Resultat Enhet Metod/refMäto.
%74.8Fukthalt b)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
mg/kg Ts13000Aluminium Al b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts25000Aluminiumoxid Al2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1200Fosfor P b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts2700Fosforoxid P2O5 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts1400Järn Fe b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts2100Järnoxid Fe2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1200Kadmium Cd b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts10000Kalcium Ca b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts14000Kalciumoxid CaO b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts5800Kalium K b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts7000Kaliumoxid K2O b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts69000Kisel Si b)*EN 14385 / ICP-AES20%
mg/kg Ts150000Kiseloxid SiO2 b)*EN 1438530%
mg/kg Ts6400Magnesium Mg b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts11000Magnesiumoxid MgO b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1500Mangan Mn b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts2400Manganoxid MnO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts3400Natrium Na b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts4600Natriumoxid Na2O b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts730Titan Ti b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts1200Titanoxid TiO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts730Arsenik As b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts2400Antimon Sb b)*EN 13656 mod. / ICP-MS15%
mg/kg Ts290Barium Ba b)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-040363-01
EUSELI2-00319331
mg/kg Ts< 2.8Berylium Be b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts12000Bly Pb b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts80Kobolt Co b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts2200Koppar Cu b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts120Krom Cr b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts64Molybden Mo b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts120Nickel Ni b)*EN 13656 mod. / ICP-MS35%
mg/kg Ts300Tenn Sn b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts52Vanadin b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts460000Zink Zn b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts68Bor B b)*SS 028150-2 / ICP-AES15%
mg/kg Ts1.1Kvicksilver Hg b)*SS 028150-2 / AFS25%
% Ts1.3Klorid b)*
g/100 g0.32Klorid a)*Silvernitrattitrering
Utförande laboratorium/underleverantör:
a) Eurofins Food & Feed Testing Sweden (Lidköping), SWEDENb) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected])Karin Karlfeldt ([email protected])Sven Brantebäck ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 737531 17 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-040358-01
EUSELI2-00319331
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-03090330Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-03-02
Provet ankom:
Övrigt fast materialMatris:
2016-03-07
Utskriftsdatum: 2016-03-22
Provmärkning: Kaka F18KS7
Provtagningsplats: 4197
Analys Resultat Enhet Metod/refMäto.
%77.9Fukthalt b)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
mg/kg Ts13000Aluminium Al b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts25000Aluminiumoxid Al2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1500Fosfor P b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts3400Fosforoxid P2O5 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts3300Järn Fe b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts4700Järnoxid Fe2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts830Kadmium Cd b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts20000Kalcium Ca b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts27000Kalciumoxid CaO b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts8100Kalium K b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts9700Kaliumoxid K2O b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts81000Kisel Si b)*EN 14385 / ICP-AES20%
mg/kg Ts170000Kiseloxid SiO2 b)*EN 1438530%
mg/kg Ts9400Magnesium Mg b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts16000Magnesiumoxid MgO b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1500Mangan Mn b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts2400Manganoxid MnO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts20000Natrium Na b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts26000Natriumoxid Na2O b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts860Titan Ti b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts1400Titanoxid TiO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts330Arsenik As b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts1800Antimon Sb b)*EN 13656 mod. / ICP-MS15%
mg/kg Ts360Barium Ba b)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-040358-01
EUSELI2-00319331
mg/kg Ts< 3.6Berylium Be b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts5700Bly Pb b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts54Kobolt Co b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts730Koppar Cu b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts87Krom Cr b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts37Molybden Mo b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts110Nickel Ni b)*EN 13656 mod. / ICP-MS35%
mg/kg Ts320Tenn Sn b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts57Vanadin b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts440000Zink Zn b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts150Bor B b)*SS 028150-2 / ICP-AES15%
mg/kg Ts0.33Kvicksilver Hg b)*SS 028150-2 / AFS25%
% Ts11Klorid b)*
g/100 g2.43Klorid a)*Silvernitrattitrering
Utförande laboratorium/underleverantör:
a) Eurofins Food & Feed Testing Sweden (Lidköping), SWEDENb) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected])Karin Karlfeldt ([email protected])Sven Brantebäck ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 737531 17 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-040359-01
EUSELI2-00319331
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-03090331Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-03-02
Provet ankom:
Övrigt fast materialMatris:
2016-03-07
Utskriftsdatum: 2016-03-22
Provmärkning: Kaka F19KS8
Provtagningsplats: 4197
Analys Resultat Enhet Metod/refMäto.
%76.9Fukthalt b)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
mg/kg Ts13000Aluminium Al b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts24000Aluminiumoxid Al2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1200Fosfor P b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts2800Fosforoxid P2O5 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts2900Järn Fe b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts4100Järnoxid Fe2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1200Kadmium Cd b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts15000Kalcium Ca b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts21000Kalciumoxid CaO b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts6100Kalium K b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts7400Kaliumoxid K2O b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts71000Kisel Si b)*EN 14385 / ICP-AES20%
mg/kg Ts150000Kiseloxid SiO2 b)*EN 1438530%
mg/kg Ts3200Magnesium Mg b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts5300Magnesiumoxid MgO b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1800Mangan Mn b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts2900Manganoxid MnO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts20000Natrium Na b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts26000Natriumoxid Na2O b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts550Titan Ti b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts920Titanoxid TiO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts200Arsenik As b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts1400Antimon Sb b)*EN 13656 mod. / ICP-MS15%
mg/kg Ts230Barium Ba b)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-040359-01
EUSELI2-00319331
mg/kg Ts< 2.9Berylium Be b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts6400Bly Pb b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts92Kobolt Co b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts570Koppar Cu b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts87Krom Cr b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts32Molybden Mo b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts170Nickel Ni b)*EN 13656 mod. / ICP-MS35%
mg/kg Ts260Tenn Sn b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts50Vanadin b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts420000Zink Zn b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts140Bor B b)*SS 028150-2 / ICP-AES15%
mg/kg Ts0.11Kvicksilver Hg b)*SS 028150-2 / AFS25%
% Ts10Klorid b)*
g/100 g2.42Klorid a)*Silvernitrattitrering
Utförande laboratorium/underleverantör:
a) Eurofins Food & Feed Testing Sweden (Lidköping), SWEDENb) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected])Karin Karlfeldt ([email protected])Sven Brantebäck ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
Eurofins Environment Testing Sweden AB
Box 737531 17 Lidköping
Tlf: +46 10 490 8110Fax: +46 10 490 8051
AR-16-SL-040364-01
EUSELI2-00319331
Analysrapport
Uppdragsmärkn.
4197
Götaverken Miljö AB Sven AnderssonBox 8876402 72 GÖTEBORG
Kundnummer: SL8420465
Provbeskrivning:
177-2016-03090336Provnummer: ProvtagareProvtagningsdatum
Sven Andersson2016-02-29
Provet ankom:
Övrigt fast materialMatris:
2016-03-07
Utskriftsdatum: 2016-03-22
Provmärkning: Repulp 1 Kaka
Provtagningsplats: 4197
Analys Resultat Enhet Metod/refMäto.
%81.1Fukthalt b)EN 14774-1,2,3:2009 mod/15414-1,2,3:2011 mod/SS187
10%
mg/kg Ts8800Aluminium Al b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts17000Aluminiumoxid Al2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1100Fosfor P b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts2400Fosforoxid P2O5 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts930Järn Fe b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts1300Järnoxid Fe2O3 b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts3900Kadmium Cd b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts7400Kalcium Ca b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts10000Kalciumoxid CaO b)*EN 13656 mod. / ICP-AES30%
mg/kg Ts2200Kalium K b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts2700Kaliumoxid K2O b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts29000Kisel Si b)*EN 14385 / ICP-AES20%
mg/kg Ts63000Kiseloxid SiO2 b)*EN 1438530%
mg/kg Ts39000Magnesium Mg b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts64000Magnesiumoxid MgO b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts4000Mangan Mn b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts6300Manganoxid MnO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts3700Natrium Na b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts5000Natriumoxid Na2O b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts890Titan Ti b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts1500Titanoxid TiO2 b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts540Arsenik As b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts820Antimon Sb b)*EN 13656 mod. / ICP-MS15%
mg/kg Ts100Barium Ba b)*EN 13656 mod. / ICP-AES30%
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 1 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39
AR-16-SL-040364-01
EUSELI2-00319331
mg/kg Ts< 2.8Berylium Be b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts6200Bly Pb b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts100Kobolt Co b)*EN 13656 mod. / ICP-MS30%
mg/kg Ts2400Koppar Cu b)*EN 13656 mod. / ICP-AES20%
mg/kg Ts58Krom Cr b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts< 22Molybden Mo b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts150Nickel Ni b)*EN 13656 mod. / ICP-MS35%
mg/kg Ts110Tenn Sn b)*EN 13656 mod. / ICP-MS20%
mg/kg Ts24Vanadin b)*EN 13656 mod. / ICP-MS25%
mg/kg Ts520000Zink Zn b)*EN 13656 mod. / ICP-AES25%
mg/kg Ts180Bor B b)*SS 028150-2 / ICP-AES15%
mg/kg Ts4.3Kvicksilver Hg b)*SS 028150-2 / AFS25%
% Ts3.3Klorid b)*
g/100 g0.62Klorid a)*Silvernitrattitrering
Utförande laboratorium/underleverantör:
a) Eurofins Food & Feed Testing Sweden (Lidköping), SWEDENb) Eurofins Environment Testing Sweden AB, SWEDEN
Kopia till:
([email protected])Karin Karlfeldt ([email protected])Sven Brantebäck ([email protected])
Denna rapport är elektroniskt signerad.
Needa Shaheen, Rapportansvarig
Mätosäkerheten, om inget annat anges, redovisas som utvidgad mätosäkerhet med täckningsfaktor 2. Undantag relaterat till analyser utförda utanför Sverige kan förekomma. Ytterligare upplysningar samt mätosäkerhet och detektionsnivåer för mikrobiologiska analyser lämnas på begäran.
Denna rapport får endast återges i sin helhet, om inte utförande laboratorium i förväg skriftligen godkänt annat. Resultaten relaterar endast till det insända provet. Sida 2 av 2
Förklaringar
Laboratoriet/laboratorierna är ackrediterade av respektive lands ackrediteringsorgan. Ej ackrediterade analyser är markerade med *
AR-003v39