Ceco Door Products DISTRIBUTOR TECH DATADistributor Tech Data
General Information:Index, Section 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-001
Profile Guidelines:Comparison of Series DQ and DJ Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-101DQ Series Slip-On Drywall Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-102DU Series Slip-On Drywall Frames. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-103DU Series WK Weatherstrip-Kerf Drywall Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-104
Frame Construction:DQ & DU Series Double Rabbet, KD Corner Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-201DQ Series 4” Head, KD Corner Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-202DC Series Cased Opening, KD Corner Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-203DQW Series Weatherstrip - Kerf, KD Corner Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . .13-204DQ & DU Series - Jamb Anchor Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-205DQ & DU Series Double/Single Rabbet, Adjustable Plumb Anchor . . . . . . . . . . . . . . . . . 13-206DC Series Cased Opening, Adjustable Plumb Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-207DQW Series Weatherstrip - Kerf, Adjustable Plumb Anchor . . . . . . . . . . . . . . . . . . . . . . 13-208DQ & DU Series and Standard Sill Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-209DQ Series Optional Sill Strap Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-210DQ Series - Hospital Sanitary Stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-211
Application Guidelines for Drywall Frames:DQ & DU Series Double and Single Rabbets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-301DC Series Cased Opening . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-302Drywall Construction Rough Opening Recommendations . . . . . . . . . . . . . . . . . . . . . . . .13-303Drywall Construction, Light Gage Metal Studs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-304, 13-305
SECTION 13 - DRYWALL FRAMES
INDEX
13-001
UNEQUAL RABBETS
EQUAL RABBETS
The backbend dimensionof Series DQ profiles isalways 1/2". The throatopening is thus equal toframe depth minus oneinch.
This page should be used for general reference only. The standard SeriesDQ and DU frame profiles and sizes are shown in detail on the followingpages.
(DU)
(DQ)
The backbend dimension ofSeries DU profiles can be sized 5/8", 9/16", or 7/16"during forming to providethe throat opening for eachstandard depth.
FACE
THROATDetermined by backbend dimension
and depth of frame
Variable Variable
1-9/16" 1-15/16"
DEPTH
1-9/16"
1-15/16"
1-9/16"
1-15/16"
DEPTH
Constant Constant Determined by depth of frame
THROAT
RABBET RABBET
SOFFIT
BACKBEND BACKBEND
STOPHEIGHT
BACKBENDRETURN
1-3/8" DOOR
1-3/4" DOOR
1-3/4" DOOR
COMPARISONSERIES DQ AND DU FRAMES
13-101
13-102
Ceco Door Products DISTRIBUTOR TECH DATADistributor Tech Data
DRYWALL FRAME PROFILESSERIES DQ, DR & DC SLIP-ON
F
E
D
M M
M E M
K
D
F
G
L
K
D
L
F
M E
K
G
M
N
N
N
FINISH
E. THROAT 1" LESS THAN DEPTH
PRIME PAINTED
G. STOP HEIGHT 5/8"
I. OPENING WIDTH: SINGLE
DOUBLE
2'-0" TO 9'-0"OPENING HEIGHT:
1'-0" THRU 4'-0"3'-0" THRU 8'-0"
K.
L. SOFFIT: 3/4" MINIMUM
J.
RABBET 1-15/16"
FOR OTHER SIZES OR VARIATIONS, CONTACT CUSTOMER SERVICE.
COLD ROLLEDMATERIALB.
ASTM A60 Galv
3-5/8" TO 14" (18, 16 and 14 GAGE)
4-5/8" TO 14" (18, 16 and 14 GAGE)D.
DEPTH SINGLE RABBET
DEPTH DOUBLE RABBET
C.
2"F. FACE *
KD H. CORNER CONDITION
BACKBENDSM. 1/2"
18, 16 & 14A. GAGE
DC
DR
DQ
3/8"BACKBEND RETURNN.
* 4" Heads are available with 2" Face Jambs
or CASED OPENING
E
K L
F
N
M
D
K
G
M
FOR OTHER SIZES OR VARIATIONS, CONTACT CUSTOMER SERVICE.
COLD ROLLED OR ASTM A60 GALV
2'-0" THRU 4'-0"
PRIME PAINTED
4'-0", 5’-0” THRU 6'-0"
4-5/8" TO 14"
4-3/4” DEPTH: 3-1/2” THROAT5-3/4” DEPTH: 4-5/8” OR 4-7/8” THROAT
4-3/4” DEPTH: 1/4”5-3/4” DEPTH: 5/16” OR 7/16”ALL OTHERS = 3/8”
4-3/4” DEPTH: 5/8”5-3/4” DEPTH: 9/16” OR 7/16”ALL OTHERS = 1/2”
UNEQUAL, 1-15/16" and 1-9/16"
DEPTH MINUS 3-1/2”
5/8"
CORNER CONDITION
OPENING HEIGHT:
OPENING WIDTH: SINGLE
BACKBENDS
RABBET
SOFFIT:
BACKBEND RETURNSN.
L.
M.
J.
K.
H.
I. DOUBLE
KD
MATERIAL
THROAT
STOP HEIGHT
(DEPTH MINUS 2 x DIM "M")
DEPTH: DOUBLE RABBET
FINISH
F.
G.
FACE
E.
D.
A. GAGE
B.
C.
2"
16
6'-8" AND 7'-0"
DRYWALL FRAME PROFILESSERIES DU SLIP-ON
13-103
13-104
Ceco Door Products DISTRIBUTOR TECH DATADistributor Tech DataSERIES DQW FRAMESWEATHERSTRIP-KERF PROFILES
F
EM M
K L
D
F
M ME
K L K
D
W
G
G
W
3/8"1/8"
N
N
3/8"1/8"
C. FINISH PRIME PAINTED
E. THROAT 1" LESS DEPTH
F. FACE 2"
G. STOP HEIGHT 5/8"
H. CORNER CONDITION K.D.
I. OPENING WIDTH: SINGLE DOUBLE
2'-0" THRU 4'-0"4'-0" THRU 8'-0"
K.
L.
RABBET EQUAL, 2-1/8" FOR 1-3/4" DOOR
FOR OTHER SIZES OR VARIATIONS, CONTACT CUSTOMER SERVICE.
18 & 16 GAGEA.
B. MATERIAL COLD ROLLED
ASTM A60 GALV
DEPTH: SINGLE RABBETD.5-1/2" TO 9"3-5/8" TO 6"
DOUBLE RABBET
2'-0" THRU 8'-0" OPENING HEIGHT:J.
SINGLE RABBETSOFFIT: DOUBLE RABBET
NORMALLY DEPTH MINUS 2-1/8"NORMALLY DEPTH MINUS 4-1/4"
BACKBENDSM. 1/2"
W. WEATHERSTRIP FOAM FILLED, FIRE RATED
DRW
DQW
BACKBEND RETURN 3/8"N.
TAB
SLOTS
ASSEMBLY PROCEDURE:1. Align head-tabs with jamb
slots. Slide components together while engaging tabs in slots. Tabs and slots are mated when miter seam is closed tight.
FRAME CORNER TABWelded to jamb.
Refer topage 13-205
HEAD
JAMB
ASSEMBLY
Series DQ and DU slip-on drywall frames are designed for installation after thepartition framework is constructed, after the gypsum wallboard is applied and the surface is finished, and after the walls are decorated. To realize this design intent,Series DQ and DU drywall frames are always furnished knocked-down.
Plumb anchor accesshole w/screw
TAB
DOUBLE RABBET FRAMES “KD” CORNER ASSEMBLY
SERIES DQ AND DU
13-201
Ceco Door Products DISTRIBUTOR TECH DATADistributor Tech Data
13-202
OPTIONAL 4” HEAD “KD” CORNER ASSEMBLYSERIES DQ, DU
ASSEMBLY PROCEDURE:1. Align head-tabs with jamb
slots. Slide components together while engaging tabs in slots. Tabs and slots are mated when miter seam is closed tight.
FRAME MITER GUIDESWelded to jamb.
HEAD
ASSEMBLY
Refer topage 13-205
Series DQ & DU slip-on drywall frames are designed for installation after the partitionframework is constructed, after the gypsum wallboard is applied and the surfaceis finished, and after the walls are decorated. To realize this design intent, SeriesDQ & DU drywall frames are always furnished knocked-down.
Welded to head.FRAME CORNER BRACKET
Plumb anchor accesshole w/screw JAMB
TAB
TAB SLOTS
TAB
SLOTS
HEAD
ASSEMBLY
ASSEMBLY PROCEDURE:1. Align head-tabs with jamb
slots. Slide components together while engaging tabs in slots. Tabs and slots are mated when miter seam is closed tight.
FRAME MITER GUIDESWelded to jamb.
Refer topage 13-205
Series DC slip-on drywall frames are designed for installation after thepartition framework is constructed, after the gypsum wallboard is applied and the surface is finished, and after the walls are decorated. To realize this design intent,Series DC drywall frames are always furnished knocked-down.
Plumb anchor accesshole w/screw
JAMB
TAB
SERIES DC CASED OPENING FRAMES“KD” CORNER ASSEMBLY
13-203
Ceco Door Products DISTRIBUTOR TECH DATADistributor Tech Data
13-204
SERIES DQW WEATHERSTRIP-KERF FRAMESCORNER ASSEMBLY
2-1/4"
ASSEMBLY PROCEDURE:1. Align head-tabs with jamb
slots. Slide components together while engaging tabs in slots. Tabs and slots are mated when miter seam is closed tight.
Series DQW slip-on drywall frames are designed for installation after thepartition framework is constructed, after the gypsum wallboard is applied and the surface is finished, and after the walls are decorated. To realize this design intent,Series DQW drywall frames are always furnished knocked-down.
hole w/screwPlumb anchor access
JAMB
HEAD
ASSEMBLY
SLOTS
FRAME MITER GUIDESWelded to jamb
Plumb AnchorPage 13-206 Page 13-206
Plumb AnchorPage 13-207Plumb Anchor
STRIKE JAMB SHOWNHINGE JAMB SIMILAR STRIKE JAMB SIMILAR
HINGE JAMB SHOWN BOTH JAMBS SIMILAR
DOUBLE RABBETSeries DQ and DU Series DR
SINGLE RABBETSeries DC
CASED OPENING
Sill AnchorsPage 13-209or 13-210
Page 13-209or 13-210
Sill AnchorsPage 13-209or 13-210
Sill Anchors
2-1/4" 2-1/4" 2-1/4"
SERIES DQ AND DU FRAMESJAMB ANCHOR DATA
13-205
13-206
Ceco Door Products DISTRIBUTOR TECH DATADistributor Tech DataSERIES DQ AND DU FRAME DOUBLE RABBETADJUSTABLE PLUMB ANCHOR
5/16" dia. access hole-Fastener sits flush
with frame soffit
Projection weld(4) places
Projection weld(4) places
JAMB
Screwed inplace
A
B
C
16 ga. galvanized steel ANCHOR BASE3-5/8" long centered in frame soffit
16 ga. galvanized steel PRESSURE BRACKET
18 ga. galvanized steel MITER GUIDEone each side
A
B
C
SINGLE RABBETPROFILE (DR Only)
3/4" MIN.
3/4"MIN.
1-1/4"MAX.
5/16" dia. access hole-fastener sits flush
with frame soffit
Projection weld(4) places
Projection weld(4) places
JAMB
Screwed inplace
A
B
C
16 ga. galvanized steel ANCHOR BASE3-5/8" long centered in frame soffit
16 ga. galvanized steel PRESSURE BRACKET
18 ga. galvanized steel MITER GUIDEone each side
A
B
C
1-3/8"MIN.
1-7/8"MAX.
SERIES DC CASED OPENING FRAMESADJUSTABLE PLUMB ANCHOR
13-207
13-208
Ceco Door Products DISTRIBUTOR TECH DATADistributor Tech DataSERIES DQW WEATHERSTRIP-KERF FRAMESADJUSTABLE PLUMB ANCHOR
16 ga. galvanized steel ANCHOR BASE3-5/8" long centered in frame soffit
16 ga. galvanized steel PRESSURE BRACKET
18 ga. galvanized steel MITER GUIDEone each side
C
B
A
Projection weld(4) places
Screwed inplace
C
B
Projection weld(4) places
A
5/16" dia. access hole-fastener sits flush
with frame soffit
SINGLE RABBETPROFILE (Series DRW)
MIN.3/4"
1-1/4"MAX.
1/2"
1/2" min.3/4" max.
SERIES DQ AND DU FRAMESSTANDARD SILL ANCHORAGE
13-209
Clearance notch (in shop)for fastener (DU only)whenever required
Punch and Dimple for#10 FH Screw oneplace each face
For cased opening frames referto page 12-305, Fig. 2
Installer fastens jambto wall framework.Screws by others.
Dimpled hole sill anchor technique is the standard design.Screw type fastener for fixing to wall is furnished byframe installer. Fastener should be of sufficient length so as to penetrate wall framework.
STUDS (wood or metal).For metal studs lighterthan 20 gauge refer topage 13-304, Fig. 1
5/8"
Door Opening1"
Rough Opening
3"
3/4"
3/4"
9/16"
1/4"1/2"
1/4"
3/4"Wall Thickness
(Throat)
STRAP type SILL ANCHORS are availablefor drywall frames as an option. Thebasic anchor construction for standardsize double rabbet profiles is shown below.
Wall Board
Base board conceals strap
Installer attaches strapto wall frameworkScrews by others
MATERIAL: 16 gage galv. steel
STRAP ANCHOR (channel type)formed to fit wall
ZEE BRACKET, length to suitframe profile
A
B
STUDS (wood or metal)For metal studs lighterthan 20 gage refer topage 13-304, Fig. 1
Anchor weldedto jamb in theshop
Portion of jambremoved forclarity
1/4"
Spot weld toZee brackets(2) places
Spot weld to
(4) placesjamb
A
B
For Cased Openingsee page 13-305Fig. 2
JAMB
13-210
Ceco Door Products DISTRIBUTOR TECH DATADistributor Tech Data
(OPTIONAL) SILL STRAP ANCHORSERIES DQ & DU FRAMES
1. Notch stop and trim area at the bottom of jamb (shaded portion) in the "flat". This terminates the flap as shown after the jamb is formed.
2a. Form flap (45? offset) to cap bottom of stop and to close the jamb flush beneath terminated
2b. Weld the special floor anchor to jamb and to flap.
3a. Weld seams between flap and jamb. Fill as required. Grind smooth.
3b. Spot paint
Seam is Completely Invisible
FLAP
FLOORANCHOR
stop.
4" or 6"
17/64"
45?
4" or 6"
SERIES DQ AND DU FRAMESHOSPITAL SANITARY STOP
13-211
ADD 2" TO DOOR OPENING WIDTHADD 1" TO DOOR OPENING HEIGHT
Push
Jamb
Head
Push
Jamb
LEVEL
PLUMB PLUMB
TO DETERMINE ROUGH OPENING:
PROCEDURE:STEP 1Begin installation by pushing the top of onejamb over the wall.Hold the top in place then push the bottom intowards and over the wall.
STEP 2Position frame head over the wall.Align head tabs with jamb slots then slide headtowards jamb and engage tabs in slots.
STEP 3Push the top of the remaining jamb over walland mate jamb slots and head tabs.Push the bottom of this jamb in towards andover the wall.Level the head.
STEP 4
screws. Alternately adjust top plumb anchorsuntil they bear firmly against studs.
Adjust intermediate plumb anchors (if present)until they too bear firmly against studsInstall mutes in holes provided in door stops.
Place a temporary wood spreader betweenjambs at sill. Adjust strike jamb to fit firmlyagainst spreader and fasten at bottom of thisjamb.
Plumb hinge jamb and fasten at sill.*
*
A.
B.
A.B.
A.
B.
C.
A.
B.C.
D.
E.
Anchor ScrewAccess Holes
TOP
Spreader
Intermediateif Present
* Some installers prefer to hang door and fit frame to door prior to
anchoring at sill.
The bottom ofeach jamb faceis punched anddimpled for atype "S" buglehead, drywallscrew
STANDARD SILL ANCHOR
Sillstrapanchor
1 1
1
e.g., For a 3068 door opening, the rough opening is: 38" x 81"
Insertfasteners
(not included)and fix jamb
to wall framing
Insert screw driver into top plumb anchor
(DOES NOT APPLY TO LABELED OR CASED OPENING FRAMES)
WALL WALL
STEP 1 STEP 2
STEP 3 STEP 4
SERIES DQ, DU AND DRSLIP-ON DRYWALL FRAMESINSTALLATION INSTRUCTIONS
13-301
OPTIONAL SILL ANCHOR
runner
ADD 3/4" TO DOOR OPENING HEIGHT
Push
Jamb
Head
Push
Jamb
LEVEL
PLUMB
TO DETERMINE ROUGH OPENING:
PROCEDURE:
STEP 1Begin installation by pushing the top of onejamb over the wall.Hold the top in place then push the bottom intowards and over the wall.
STEP 2Position frame head over the wall.Align head tabs with jamb slots then slide headtowards jamb and engage tabs in slots.
STEP 3Push the top of the remaining jamb over walland mate jamb slots and head tabs.Push the bottom of this jamb in towards andover the wall.Level the head.
STEP 4
screws. Alternately adjust top plumb anchorsuntil they bear firmly against studs.
Adjust intermediate plumb anchors (if present)until they too bear firmly against studs
Place a temporary wood spreader betweenjambs at sill. Adjust strike jamb to fit firmlyagainst spreader and fasten at bottom of thisjamb.
Plumb hinge jamb and fasten at sill.
*
A.
B.
A.B.
A.
B.
C.
A.
B.C.
D.
Anchor ScrewAccess Holes
TOP
Spreader
Intermediateif Present
* Some installers prefer to hang door and fit frame to door prior to
anchoring at sill.
The bottom ofeach jamb faceis punched anddimpled for atype "S" buglehead, drywallscrew
STANDARD SILL ANCHOR
Sillstrapanchor
1 1
1
Insertfasteners
(not included)and fix jamb
to wall framing
Insert screw driver into top plumb anchor
WALL WALL
(DOES NOT APPLY TO DRYWALL FRAMES WITH INTEGRAL DOOR STOPS)
ADD 2-3/4" TO DOOR OPENING WIDTH
e.g., For a 3068 door opening, the rough opening is 38-3/4" x 80-3/4"
PLUMB*
STEP 1 STEP 2
STEP 3 STEP 4
OPTIONAL SILL ANCHOR
runner
13-302
Ceco Door Products DISTRIBUTOR TECH DATADistributor Tech DataSERIES DC, CASED OPENING,SLIP-ON DRYWALL FRAMEINSTALLATION INSTRUCTIONS
PARTITION ELEVATION
1. Jambs of rough framing should beplumb and in the same plane.See Fig. 1.
2. Rough header should be level andform a right angle (90?) with jambs.
3. To determine rough openingdimension, refer to installationinstructions.
4. Measurement for rough openingshould be taken:A. WIDTH at head and sillB. HEIGHT at both jambs
5. Tolerances for rough openingdimensions: minus = 0, plus = 1/2"(total).
RIGHT WRONG WRONG
Plu
mb
Lin
e
Plu
mb
Lin
e
Plu
mb
Lin
e
Walls adjacent todoor opening areplumb and in thesame plane.
Walls are notin the same plane.
Walls are in thesame plane butare not plumb.
4A
4A
4B 4B
2 2
Fig.1
Fig.1
Fig.1
DRYWALL CONSTRUCTIONROUGH OPENING RECOMMENDATIONS
13-303
Distortion Of Light Gage MetalStuds Or Floor Runners (ThinnerThan 20 Gage) May Occur WhenThe Plumb Anchor Is CompressedOr When Point Of Sill AnchorFastener Does Not PenetrateFloor Runner.
The following methods will providethe necessary rigidity to preventthis distortion:
1. Provide wood (2x4) cripples at the door frame side of the light gage studs. Cripples to run from floor to underside of steel stud header. Refer to Fig. 1.
2 Provide two 16 gage steel studs (back to back) on either side of the door frame. Refer to Fig. 2.
If only light gage steel studs are usedfor framing the drywall frame, refer topage 13-305 Fig. 1 and 2.
Rough OpeningWidth Dimension
Heig
ht D
imen
sion
Roug
h Op
enin
g
Width DimensionRough Opening
Heig
ht D
imen
sion
Roug
h Op
enin
g
R
LS
WC
HS
Steel Studs, less than 20 gage
Steel Floor Runner
Wood Cripple (1-1/2" thick)
Steel Studs, 16 gage
Note: Rip 2 x 4 to fit ifstud is less than 3-1/2"
WC
LS
R R
LS
LS
R R
LS
HS
LS
HS
WC
Section A-A
Section B-B
A A
BB
Rough OpeningWidth Dimension
Width DimensionRough Opening
LS
Fig. 1
Fig. 2
JAMBS
SILL
13-304
Ceco Door Products DISTRIBUTOR TECH DATADistributor Tech DataDRYWALL CONSTRUCTIONLIGHT GAGE METAL STUDS
1-3/8"
Runner 5/8" pastrough-in opening
SERIES DQ, DU and DR
Notch studs as required toprovide clearance for block.
Cut block to fit and placein channel as shown. Alignwith end of runner.(Block need not exceed 6" long.)
Less than 20 gage
Either type ofsill anchor
Project floor runners 5/8"past rough-in openingsat both corners. (Notrequired when optional strap type sill anchor isused.) See Fig. 3
A and B proceed as in Fig. 1 above.
A
B
Fig. 1
Fig. 2
A
B
B
A
Less than 20 gage
SERIES DC withSTANDARD SILL ANCHOR
Fig. 3
DRYWALL CONSTRUCTIONLIGHT GAGE METAL STUDS
13-305