Distribution Grid Automation Controller COM600, rackmount Technical Manual

Transcript of Distribution Grid Automation Controller COM600, … · 2018-05-09 · Operating a system at a high...

Distribution Grid Automation ControllerCOM600, rackmountTechnical Manual

Document ID: 1VAC456801-MBIssued: 2016-06-17

Revision: AProduct version: 4.1

© Copyright 2016 ABB. All rights reserved

Copyright

This document and parts thereof must not be reproduced or copied without writtenpermission from ABB, and the contents thereof must not be imparted to a third party, norused for any unauthorized purpose.

The software or hardware described in this document is furnished under a license and maybe used, copied, or disclosed only in accordance with the terms of such license.

TrademarksABB and Relion are registered trademarks of the ABB Group. All other brand or productnames mentioned in this document may be trademarks or registered trademarks of theirrespective holders.

WarrantyPlease inquire about the terms of warranty from your nearest ABB representative.

ABB Inc.

Distribution Automation

4300 Coral Ridge Drive

Coral Springs, FL 33065, USA

Toll-free: 1 (800) 523-2620

Phone: +1 954-752-6700

Fax: +1 954 345-5329

http://www.abb.com/substationautomation

Disclaimer

The data, examples and diagrams in this manual are included solely for the concept orproduct description and are not to be deemed as a statement of guaranteed properties. Allpersons responsible for applying the equipment addressed in this manual must satisfythemselves that each intended application is suitable and acceptable, including that anyapplicable safety or other operational requirements are complied with. In particular, anyrisks in applications where a system failure and/or product failure would create a risk forharm to property or persons (including but not limited to personal injuries or death) shallbe the sole responsibility of the person or entity applying the equipment, and those soresponsible are hereby requested to ensure that all measures are taken to exclude ormitigate such risks.

This product has been designed to be connected and communicate data and informationvia a network interface which should be connected to a secure network. It is the soleresponsibility of the person or entity responsible for network administration to ensure asecure connection to the network and to take the necessary measures (such as, but notlimited to, installation of firewalls, application of authentication measures, encryption ofdata, installation of anti virus programs, etc.) to protect the product and the network, itssystem and interface included, against any kind of security breaches, unauthorized access,interference, intrusion, leakage and/or theft of data or information. ABB is not liable forany such damages and/or losses.

This document has been carefully checked by ABB but deviations cannot be completelyruled out. In case any errors are detected, the reader is kindly requested to notify themanufacturer. Other than under explicit contractual commitments, in no event shall ABBbe responsible or liable for any loss or damage resulting from the use of this manual or theapplication of the equipment.

Conformity

This product complies with the directive of the Council of the European Communities onthe approximation of the laws of the Member States relating to electromagneticcompatibility (EMC Directive 2004/108/EC) and concerning electrical equipment for usewithin specified voltage limits (Low-voltage directive 2006/95/EC). This conformity isthe result of tests conducted by ABB in accordance with the product standards EN 50263and EN 60255-26 for the EMC directive, and with the product standards EN 60255-1 andEN 60255-27 for the low voltage directive. The product is designed in accordance with theinternational standards of the IEC 60255 series and ANSI C37.90.

Table of contents

Section 1 Introduction............................................................................3This manual.............................................................................................. 3Intended audience.................................................................................... 3Product documentation.............................................................................3

Document revision history................................................................... 3Related documentation........................................................................4

Symbols and conventions.........................................................................4Symbols...............................................................................................4Document conventions........................................................................ 4

Section 2 Safety instructions................................................................. 5General safety.......................................................................................... 5Environmental factors............................................................................... 5Power safety.............................................................................................6CMOS battery........................................................................................... 7

Removing battery.................................................................................8Maintenance and disposal of components............................................... 9

Section 3 Mounting..............................................................................11Rack-mounting the device...................................................................... 11

Section 4 Physical connections...........................................................13Rear power and I/O connections............................................................ 13Jumper settings and pin definitions........................................................ 14

Jumper settings................................................................................. 16Rear panel pin assignments.............................................................. 23

Section 5 Technical data..................................................................... 29

Section 6 Glossary.............................................................................. 31

Table of contents

COM600, rackmount 1Technical Manual

2

Section 1 Introduction

1.1 This manual

The technical manual contains mounting instructions and descriptions of physicalconnections. The manual can be used as a technical reference during the engineeringphase, installation and commissioning phase, and during normal service.

1.2 Intended audience

This manual addresses system engineers and installation and commissioning personnel,who use technical data during engineering, installation and commissioning, and in normalservice.

The system engineer must have a thorough knowledge of protection systems, protectionequipment, protection functions and the configured functional logic in the protectionrelays. The installation and commissioning personnel must have a basic knowledge inhandling electronic equipment.

1.3 Product documentation

1.3.1 Document revision historyDocument revision/date Product version HistoryA/2016-06-17 4.1 First release

Download the latest documents from the ABB Web sitehttp://www.abb.com/substationautomation.

1VAC456801-MB A Section 1Introduction

COM600, rackmount 3Technical Manual

1.3.2 Related documentation

Product series- and product-specific manuals can be downloaded from the ABB Web sitehttp://www.abb.com/substationautomation.

1.4 Symbols and conventions

1.4.1 Symbols

The electrical warning icon indicates the presence of a hazard which couldresult in electrical shock.

The warning icon indicates the presence of a hazard which could result inpersonal injury.

The caution icon indicates important information or warning related to theconcept discussed in the text. It might indicate the presence of a hazardwhich could result in corruption of software or damage to equipment orproperty.

The information icon alerts the reader of important facts and conditions.

The tip icon indicates advice on, for example, how to design your projector how to use a certain function.

Although warning hazards are related to personal injury, it is necessary to understand thatunder certain operational conditions, operation of damaged equipment may result indegraded process performance leading to personal injury or death. Therefore, complyfully with all warning and caution notices.

1.4.2 Document conventions

• Abbreviations and acronyms are spelled out in the glossary. The glossary alsocontains definitions of important terms.

Section 1 1VAC456801-MB AIntroduction

4 COM600, rackmountTechnical Manual

Section 2 Safety instructions

2.1 General safety

The device arrives assembled in a shipping box and needs to be carefully unpacked toavoid causing any damage. No special tools or considerations are needed.

The device is under no special consideration for lifting, and can be lifted by a singleperson.

Before cleaning this device, the power cord needs to be disconnected. The outside devicechassis surfaces can be cleaned with a soft cloth dampened with water. A mild detergentmay be used. Aerosol cleaners, or any cleaner that contains flammable substances mustnot be used. The device should be allowed to dry before reconnecting the power cord tothe electrical outlet.

Check equipment ratings, operating instructions and installationinstructions before commissioning or maintenance.

Do not operate this device with any covers removed.

Do not use this device in a wet environment where it could be subject tosplashing, sprayed or dripping water, or other liquids.

2.2 Environmental factors

TemperatureThe ambient temperature within an enclosure may be greater than room ambienttemperature. Installation in an enclosure should be such that the amount of air flowrequired for safe operation is not compromised. Consideration should be given to themaximum rated ambient temperature.

1VAC456801-MB A Section 2Safety instructions

COM600, rackmount 5Technical Manual

Overheating can cause a variety of problems, including premature aging and failure ofchips or mechanical failure of devices.

If the system has been exposed to abnormally cold temperatures, a two hour warm-upperiod is necessary to bring it up to normal operating temperature before turning it on.Failure to do so may cause damage to internal components, particularly the hard diskdrive.

HumidityHigh-humidity can cause moisture to enter and accumulate in the system. This moisturecan cause corrosion of internal components and degrade such properties as electricalresistance and thermal conductivity. Extreme moisture buildup inside the system canresult in electrical shorts, which can cause serious damage to the system. Buildings inwhich climate is controlled usually maintain an acceptable level of humidity for systemequipment. However, if a system is located in an unusually humid location, a dehumidifiercan be used to maintain the humidity within an acceptable range.

AltitudeOperating a system at a high altitude (low pressure) reduces the efficiency of the coolingfans to cool the system. This can cause electrical problems related to arcing and coronaeffects. This condition can also cause sealed components with internal pressure, such aselectrolytic capacitors, to fail or perform at reduced efficiency.

2.3 Power safety

The device relies on an internal power supply fuse for short-circuit (overcurrent)protection.

Ensure that the plug/socket combination on the rear panel of the device isaccessible at all times because it serves as the main power disconnectingthe device.

The rear panel power connector supports +Vin, -Vin, and GND. Both Vin pins are isolatedfrom the chassis while the GND pin is connected to the chassis ground.

Chassis is required to be grounded with a 18 AWG/300 V wire to the designated andlabeled grounding post on the chassis. System is required to connect to power using a 18AWG/300 V wire.

Ensure the integrity of any protective conductor connections beforecarrying out any other actions.

Section 2 1VAC456801-MB ASafety instructions

6 COM600, rackmountTechnical Manual

Power protectionThe greatest threats to a system’s supply of power are power loss, power spikes, and powersurges caused by electrical storms, which interrupt system operation or damage systemcomponents. To protect the system, always properly ground powered device and use oneof the following devices.

• Surge protector• Surge protectors are available in a variety of types and usually provide a level

of protection proportional with the cost of the device. Surge protectors preventvoltage spikes from entering a system through the AC power cord. Surgeprotectors, however, do not offer protection against brownouts, which occurwhen the voltage drops more than 20 percent below the normal AC line voltagelevel.

• Line conditioner• Line conditioners go beyond the overvoltage protection of surge protectors.

Line conditioners keep a system’s AC power source voltage at a fairly constantlevel and, therefore, can handle brownouts. Because of this added protection,line conditioners cost more than surge protectors. However, line conditionerscannot protect against a complete loss of power.

• Uninterruptible power supply• Uninterruptible power supply (UPS) systems offer the most complete

protection against variations on power because they use battery power to keepthe server running when AC power is lost. The battery is charged by the ACpower while it is available, so when AC power is lost, the battery can providepower to the system for a limited amount of time, depending on the UPSsystem. UPS systems range in price from a few hundred dollars to severalthousand dollars, with the more expensive units allowing you to run largersystems for a longer period of time when AC power is lost. UPS systems thatprovide only 5 minutes of battery power let you conduct an orderly shutdownof the system, but are not intended to provide continued operation. Surgeprotectors should be used with all UPS systems, and the UPS system should beUnderwriters Laboratories (UL) safety approved.

2.4 CMOS battery

Replace the CMOS battery only with the same or equivalent typerecommended by the manufacturer. A risk of explosion is possible ifbattery is incorrectly replaced.

1VAC456801-MB A Section 2Safety instructions

COM600, rackmount 7Technical Manual

Dispose of used batteries according to the manufacturer’s instructions.

2.4.1 Removing battery

To avoid internal component damage, observe proper ESD precautionswhen working inside the device chassis.

1. Disconnect power cord.Remove the chassis lid by removing the screws on the bottom and sliding the lid off.

2. Locate the CMOS battery to the left of the HDMI port.

GUID-BD67DF0E-1422-4C02-B629-EF0F7EED414E V1 EN

Figure 1: Locating the CMOS battery

3. Gently press the release tab of the battery holder.4. Rotate the battery up beyond the latch and remove the battery from the device.

Section 2 1VAC456801-MB ASafety instructions

8 COM600, rackmountTechnical Manual

2.5 Maintenance and disposal of components

The CMOS battery is the only customer serviceable part of the system.

Any decommissioned part or system shall be handled by the policies and procedures of theuser or facility.

Ensure that the equipment is installed, operated and used for its intendedfunction in the manner specified by the manufacturer. If this is not thecase, then any safety protection provided by the equipment may beimpaired.

1VAC456801-MB A Section 2Safety instructions

COM600, rackmount 9Technical Manual

10

Section 3 Mounting

3.1 Rack-mounting the device

1. Mount the device within a 19 inch rack and use a fastening hardware capable ofsupporting the system weight.

2. Ensure that the installed device has at least 1U of space above or below.

A

DE

CB

F

GGUID-F250971E-4218-45FA-87FA-36E5614B8658 V1 EN

Figure 2: Device dimensions

A 17.00 in

B 3.50 in

C 2.94 in

D 18.45 in

E 18.04 in

F 18.95 in

G 11.44 in

1VAC456801-MB A Section 3Mounting

COM600, rackmount 11Technical Manual

12

Section 4 Physical connections

4.1 Rear power and I/O connections

1GUID-A3B32D66-3381-480D-9C81-7C95CE90CAFD V1 EN

Figure 3: Rear power connection

1 Power connection (V-, Gnd, V+)

1VAC456801-MB A Section 4Physical connections

COM600, rackmount 13Technical Manual

1 2 3 4

5 6 7 8 9GUID-76A2F185-7F03-45A2-B10A-E308279F2B8C V1 EN

Figure 4: Rear I/O connections

1 COM

2 VGA

3 RJ-45

4 S/PDIF

5 DVI-D

6 HDMI

7 USB 2.0

8 USB 3.0

9 Audio stack

4.2 Jumper settings and pin definitions

The product has several jumpers which must be properly configured to ensure correctoperation.

Jumper connectorFor a three-pin jumper (see Figure 5), the jumper setting is designated “1-2” when thejumper connects pins 1 and 2. Similarly, the jumper setting is designated “2-3” when pins2 and 3 are connected and so on. The thick lines surrounding a jumper pin indicates pin No.1.

To move a jumper from one position to another, needle-nose pliers or tweezers should beused to pull the pin cap off the pins and move it to the desired position.

Section 4 1VAC456801-MB APhysical connections

14 COM600, rackmountTechnical Manual

GUID-0C175D6F-B238-4A83-9E4E-EF1B12579B92 V1 EN

Figure 5: Jumper and connector locations

1VAC456801-MB A Section 4Physical connections

COM600, rackmount 15Technical Manual

1 2 3 4 5 6 7GUID-0C00B57D-A3BF-49AE-98E4-C323626CEF89 V1 EN

Figure 6: Rear panel connector labels

1 CN13

2 CN12

3 HDMI1

4 CN10

5 CN11

6 AUDIO1

7 CN14

4.2.1 Jumper settings

To ensure correct system configuration, the jumpers have to be set to enable/disable orchange functions.

Table 1: Jumper descriptions

Label DescriptionJP1 AT/ATX mode selection

JP2 Signal/Power selection for COM5

JP3 Panel and backlight power selection for LVDS2

JP4 Signal/Power selection for COM6

JP5 Panel and backlight power selection for LVDS1

JP6 Backlight power enable selection for LVDS1

JP7 Backlight power enable selection for LVDS2

JP8 RTC reset selection

JP9 SRTC reset selection

JP11 Flash description security override

Section 4 1VAC456801-MB APhysical connections

16 COM600, rackmountTechnical Manual

JP1 AT/ATX mode selection

GUID-C0A3F9FF-D03A-4152-9854-B18F7CC1AC22 V1 EN

Table 2: JP1 AT/ATX mode selection

Jumper Status1-2 short ATX mode

2-3 short AT mode

JP3 panel backlight power selection for LVDS2

GUID-CFA2C575-FCB3-4C40-8A4F-468904D20A9B V1 EN

Table 3: JP3 panel backlight power selection for LVDS2

Jumper Setting Status1 1-3 Backlight power = +12 V

3-5 Backlight power = +5 V

2 2-4 Panel power = +3.3 V

4-6 Panel power = +5 V

Pitch: 2.54 mm [YIMTEX 3362*03SAGR]

1VAC456801-MB A Section 4Physical connections

COM600, rackmount 17Technical Manual

JP4 signal/power selection for COM6

GUID-3BCCAFBF-6A27-475C-AE47-E722105095FF V1 EN

Table 4: JP4 signal/power selection for COM6

Jumper Setting Function1 1-3 short Pin 1 = +12 V

3-5 short Pin 1 = +5 V

5-7 short Pin 1 = +5 V

7-9 short Pin 1 = DCD

2 2-4 short Pin 9 = +12 V

4-6 short Pin 9 = +5 V

6-8 short Pin 9 = +5 V

8-10 short Pin 9 = RI

Pitch: 2.54 mm [YIMTEX 3362*05SANGR]

JP5 panel backlight power selection for LVDS1

GUID-01BE669E-2EF2-4A3C-B54F-3F00A570940F V1 EN

Section 4 1VAC456801-MB APhysical connections

18 COM600, rackmountTechnical Manual

Table 5: JP5 panel backlight power selection for LVDS1

Jumper Setting Status1 1-3 Backlight power = +12 V

3-5 Backlight power = +5 V

2 2-4 Panel power = +3.3 V

4-6 Panel power = +5 V

Pitch: 2.54 mm [YIMTEX 3362*03SAGR]

JP6 backlight power enable selection for LVDS1

GUID-B67F7AEF-3BF5-4D55-9EC2-8D15E63B7512 V1 EN

Table 6: JP6 backlight power enable selection for LVDS1

Jumper Setting Status1 1-3 Backlight enable voltage = +3.3 V

3-5 Backlight enable voltage = +5 V

2 2-4 Active high

4-6 Active low

Pitch: 2.0 mm[PINREX 222-97-03GBB1]

1VAC456801-MB A Section 4Physical connections

COM600, rackmount 19Technical Manual

JP7 backlight power enable selection for LVDS2

GUID-0162C0FF-8B6D-4246-8AF3-391907020D8C V1 EN

Table 7: JP7 backlight power enable selection for LVDS2

Jumper Setting Status1 1-3 Backlight enable voltage = +3.3 V

3-5 Backlight enable voltage = +5 V

2 2-4 Active high

JP8 RTC reset selection

GUID-0162C0FF-8B6D-4246-8AF3-391907020D8C V1 EN

Table 8: JP8 RTC reset selection

Jumper Status1-2 open Normal operation

1-2 short Clear RTC CMOS

Pitch: 2.54 mm [YIMTEX 3321*02SAGR (6T)]

Section 4 1VAC456801-MB APhysical connections

20 COM600, rackmountTechnical Manual

JP9 SRTC reset selection

GUID-3CF5F336-B5F5-4430-8BAC-4316AFCD3D26 V1 EN

Table 9: JP9 SRTC reset selection

Jumper Status1-2 open Normal operation

1-2 short Clear ME registers

Pitch: 2.54 mm [YIMTEX 3321*02SAGR (6T)]

JP11 flash description security override

GUID-19F88CFF-77CD-446F-9F6A-6277E721E734 V1 EN

Table 10: JP11 flash description security override

Jumper Status1-2 Disable

2-3 Enable

Pitch: 2.54 mm [YIMTEX 3321*03SAGR (6T)] (for Quanmax debug only)

1VAC456801-MB A Section 4Physical connections

COM600, rackmount 21Technical Manual

FP1 front panel 1 pin header

GUID-02C947B3-82AD-4FD0-BC36-B822D12C2310 V1 EN

Table 11: FP1 front panel 1 pin header

Pin Signal Pin Signal1 Reset button + 2 Speaker +

3 Reset button - 4 NC

5 HDD LED + 6 Internal speaker-

7 HDD LED - 8 Speaker-

Pitch: 2.54 mm [YIMTEX 3362*04SANGR]

Internal Buzzer is enabled when pin 6-8 is shorted.

FP2 front panel 2 pin header

GUID-B8620084-DD6E-463B-A7DE-56575C63DA09 V1 EN

Section 4 1VAC456801-MB APhysical connections

22 COM600, rackmountTechnical Manual

Table 12: FP2 front panel 2 pin header

Pin Signal Pin Signal1 Power LED + 2 Power button +

3 NC 4 Power button -

5 Power LED - 6 NC

7 Keyboard lock 8 SMBus data

9 GND 10 SMBus clock

Pitch: 2.54 mm [YIMTEX 3362*05SANGR]

4.2.2 Rear panel pin assignmentsTable 13: Rear panel connector list

Label DescriptionAUDIO1 3 stack-up Azalia audio phone jack

CN10 LAN1 and USB2.0 port 0,1 connector

CN11 LAN2 and USB2.0 port 2,3 connector

AUDIO1 3 stack-up Azailia audio phone jack

BLUE

GREEN

PINK

GUID-54CF08EB-AA16-45C6-B196-E97BB814EC75 V1 EN

Table 14: AUDIO1 3 stack-up Azailia audio phone jack

Connector SignalBLUE LINE IN

GREEN LINE OUT

PINK MIC IN

[Foxconn JA33331-H11P-4F]

1VAC456801-MB A Section 4Physical connections

COM600, rackmount 23Technical Manual

CN10 LAN1 and USB2.0 port 0, 1 connector

GUID-6B938A8D-5422-4682-A367-D5FAA232B7F0 V1 EN

Table 15: CN10 LAN1 and USB2.0 port 0, 1 connector

Pin Signal Pin Signal1 MDI[0]+ 9 +USBVCC

2 MDI[0]- 10 USB_A-

3 MDI[1]+ 11 USB_A+

4 MDI[1]- 12 GND

5 MDI[2]+ 13 +USBVCC

6 MDI[2]- 14 USB_B-

7 MDI[3]+ 15 USB_B+

8 MDI[3]- 16 GND

[UDE RU1-161F9WGF (XB)]

CN11 LAN2 and USB2.0 port 2, 3 connector

GUID-FDFF8E73-9E1A-4C37-AAE3-594B3197434D V1 EN

Section 4 1VAC456801-MB APhysical connections

24 COM600, rackmountTechnical Manual

Table 16: CN11 LAN2 and USB2.0 port 2, 3 connector

Pin Signal Pin Signal1 MDI[0]+ 9 +USBVCC

2 MDI[0]- 10 USB_A-

3 MDI[1]+ 11 USB_A+

4 MDI[1]- 12 GND

5 MDI[2]+ 13 +USBVCC

6 MDI[2]- 14 USB_B-

7 MDI[3]+ 15 USB_B+

8 MDI[3]- 16 GND

[UDE RU1-161F9WGF (XB)]

Table 17: LAN LED configuration

LED State DescriptionLink (left) Green/Orange Link 1000

Orange Link 100

Green Link 10

Off No Link

Active (right) Yellow Activity

Yellow blink

Off No activity

CN12 CRT DB-15 and DVI-D connector

GUID-BAD3ECB1-9D24-4F80-ADC6-7FEC1CE1BE26 V1 EN

1VAC456801-MB A Section 4Physical connections

COM600, rackmount 25Technical Manual

Table 18: CN12 CRT DB-15 and DVI-D connector

Signal Pin Pin SignalRed V1 V2 Green

Blue V3 V4 NC

GND V5 V6 GND

GND V7 V8 GND

+5V V9 V10 GND

NC V11 V12 DDC_DATA

HSYNC V13 V14 VSYNC

DDC_CLK V15

Signal Pin Pin SignalTX2- 1 2 TX2+

GND 3 4 NC

NC 5 6 DDC_CLK

DDC_DATA 7 8 NC

TX1- 9 10 TX1+

GND 11 12 NC

NC 13 14 +5V

GND 15 16 HTPLG

TX0- 17 18 TX0+

GND 19 20 NC

NC 21 22 GND

TXC+ 23 24 TXC-

GND C

[FAN YING G205D2C01012PHN]

CN13 RS-232/422/485 Port 1, 2 connector

GUID-C3105402-D962-4BA3-9E41-11E9EC65F61B V1 EN

Section 4 1VAC456801-MB APhysical connections

26 COM600, rackmountTechnical Manual

Table 19: CN13 RS-232/422/485 Port 1, 2 connector

Port Pin RS-232 RS-422 Half duplexRS-485

Full duplexRS-485

1 B1 DCD TX- DATA- TX-

B2 RXD RX+ N/A RX+

B3 TXD TX+ DATA+ TX+

B4 DTR RX- N/A RX-

B5 GND GND GND GND

B6 DSR N/A N/A N/A

B7 RTS N/A N/A N/A

B8 CTS N/A N/A N/A

B9 RI N/A N/A N/A

Port Pin RS-232 RS-422 Half duplexRS-485

Full duplexRS-485

2 A1 DCD TX- DATA- TX-

A2 RXD RX+ N/A RX+

A3 TXD TX+ DATA+ TX+

A4 DTR RX- N/A RX-

A5 GND GND GND GND

A6 DSR N/A N/A N/A

A7 RTS N/A N/A N/A

A8 CTS N/A N/A N/A

A9 RI N/A N/A N/A

[FAN YING D20HB1102112PN]

RS-232/422/485 can be selected in BIOS setup.

CN14 Optical S/PDIF output connector

GUID-48336F11-339D-4815-9AB8-E3CB95E43276 V1 EN

[FOXCONN 2F11TC1-EM90-4F]

1VAC456801-MB A Section 4Physical connections

COM600, rackmount 27Technical Manual

HDMI connector

GUID-DD58B976-79AE-4E7B-AC50-ED876BDD0043 V1 EN

Table 20: HDMI connector

Pin Signal1 TMDS data2+

2 Ground

3 TMDS data2–

4 TMDS data1+

5 Ground

6 TMDS data1–

7 TMDS data0+

8 Ground

9 TMDS data0–

10 TMDS clock+

11 Ground

12 TMDS clock–

13 Reserved

14 Reserved

15 DDC_CLK

16 DDC_DATA

17 Ground

18 +5 V power

19 Hot plug detect

Section 4 1VAC456801-MB APhysical connections

28 COM600, rackmountTechnical Manual

Section 5 Technical data

Table 21: Technical specifications

Description ValueProcessor Intel® Core™ i5-2510E, 2.50 GHz

Memory 2 × 2 GB DDR3 SDRAM-1333, max. 8 GB

Expansion 2 × 32-bit PCI expansion slot

VGA/Keyboard/Mouse 1 × VGA1 × DVI1 × HDMIUSB for keyboard and mouse

Ethernet 2 × 10/100/1000 Base-TX RJ-45 connectors

Storage drives 1 × industrial SSD, 30 GB1 × industrial CF card, 32 GB

Serial ports 2 × RS-232/RS-422/RS-485

Audio Mic-in/Line-in/Line-out

USB ports 2 × USB 2.0 ports2 × USB 3.0 ports

Power input 1924-13(H): ATX, input voltage: 100...240 V AC/125...250 V DC, 100 W: 50...60 Hz ±5%

1924-15(L): ATX, input voltage: 19...72 V DC, 100 W

Maximum start-up inrush current 1924-13(H): V AC: <70 A at 230 V AC/V DC: <35 A at115 V

1924-15(L): <2.7 A at 48 V DC

Transient overvoltage I/P-O/P: 2.0 kV AC, I/P-PE: 1.5 kV AC, O/P-PE:0.5kV AC : 1 minute

Table 22: Mechanical specifications

Description ValueConstruction Cold rolled steel chassis

Color White chassis

Mounting Rackmount

Dimensions (W × H × D) 19 × 3.5 × 12 in

Net weight 10 lb. (4.53 kg)

IP rating IPX0

1VAC456801-MB A Section 5Technical data

COM600, rackmount 29Technical Manual

Table 23: Environmental specifications

Description ValueOperating humidity 0...90%, noncondensing

Storage temperature -40...185°F (-40...85°C)

Ambient air temperature1)

• Upper limit ≤+70°C (158ºF)

• Lower limit ≥-20°C (-4ºF)

Solar radiations Negligible

Air pollution (dust, salt, smoke, corrosive orflammable gas, or vapors)

No significant air pollution2)

Relative humidity, 24 h average 5...95%3)

Vibration, earth tremors According to IEC 60255-21 series, environmentClass 0 or Class 1

Electromagnetic disturbances Electromagnetic environment defined by immunitytest levels of IEC 60255-26, Class B4)

1) The ambient air temperature is the maximum or minimum temperature around the enclosure of theprotection relay. Depending on the type of climate and the type of weather-protected location where ameasuring relay and protection equipment is mounted, temperature limits may be more or less severe.Consequently, the equipment should be capable of operating under one of the preferred standardtemperature ranges listed in 5.8.

2) These conditions correspond to maximum values given for classes 3C1 and 3S1 in IEC 60721-3-3.3) No condensation or ice is considered.4) This is in line with basic standard IEC/TR 61000-2-5, classification of electronic environments, for a location

class type 5 listing attributes for a heavy industrial location, a generating station or a switch-yard.

Table 24: Regulatory information

Description ReferenceEMC Complies with EMC Directive 2004/108/EC EN

55022, IEC 60255-26, IEC 61000-6-2, IEC61000-6-4

Safety Complies with Low Voltage Directive 2006/95/ECIEC 60255-27, IEC 60255-1

Pollution Degree 2

Insulation Class 1

Section 5 1VAC456801-MB ATechnical data

30 COM600, rackmountTechnical Manual

Section 6 Glossary

AC Alternating currentANSI American National Standards InstituteATX Advanced technology eXtendedCF Compact flashDC 1. Direct current

2. Disconnector3. Double command

DDR3 SDRAM Double data rate type three synchronous dynamic random-access memory

DVI Digital visual interfaceEMC Electromagnetic compatibilityEthernet A standard for connecting a family of frame-based computer

networking technologies into a LANHDMI High definition multimedia interfacePCI Peripheral component interconnectRJ-45 Galvanic connector typeRS-232 Serial interface standardRS-422 Serial communication standard (EIA–422)RS-485 Serial link according to EIA standard RS485SSD Solid state driveUSB Universal serial busVGA Video graphics array

1VAC456801-MB A Section 6Glossary

COM600, rackmount 31Technical Manual

32

33

Contact us

ABB Inc.Distribution Automation4300 Coral Ridge DriveCoral Springs, FL 33065, USAPhone +1 (800) 523-2620Phone +1 954-752-6700Fax +1 954 345-5329

www.abb.com/substationautomation

1VA

C45

6801

-MB

Cop

yrig

ht 2

016

AB

B. A

ll rig

hts

rese

rved

.