Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4...

25
Discovery 1-4 Loop Analogue Discovery 1-4 Loop Analogue Addressable Control Panels Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices Extensive mode-change options by day/night and special group allocations Day/Night delay of alarm and cause/effect outputs 4 Inbuilt Software Delay Timers 500mA output per loop with highly stable voltage platform, even under mains-failed conditions

Transcript of Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4...

Page 1: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

Discovery 1-4 Loop Analogue Discovery 1-4 Loop Analogue Addressable Control PanelsAddressable Control Panels

• From 1-4 loops

• LPCB approval to EN54 2 & 4

• Fully compatible with all Apollo XP95 and Discovery devices

• Extensive mode-change options by day/night and special group allocations

• Day/Night delay of alarm and cause/effect

outputs

• 4 Inbuilt Software Delay Timers

• 500mA output per loop with highly stable voltage platform, even under mains-failed conditions

Page 2: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

Discovery 1-4 Loop Analogue Discovery 1-4 Loop Analogue Addressable Control PanelsAddressable Control Panels

• Additional Discovery detector functions

– Print Drift Compensation level by loop

– Print Device Date of Manufacture

– Enable/Disable LED pulsing mode

• Automatic recognition of Apollo and Control

Equipment outstations

• User friendly controls and a clear, unambiguous

screen

• Fully networkable with other Discovery and Voyager panels

• Complies with EMC and LVD Directives

• Windows-based, full upload/download PC software package

Page 3: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

Discovery 1-4 Loop Analogue Discovery 1-4 Loop Analogue Addressable Control PanelsAddressable Control Panels

• New Phase 5 Software upgrade

• 61 customer Led Enhancements Including:-

– Fast loop output response (3 seconds with

BGU operation

– Latest Apollo devices supported including

intelligent reflective beam, discovery CO

detector, XP95 multisensor etc

– Local cause / effect enhanced to 3 x

capacity

– General output disablement facility

– Configurable class change – pulse /

continuous

– Full loop sounder synchronisation

supported

Page 4: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

ALARMS

FIRE & FAULT RELAYS

BREAK GLASS

F IRE

PRESS HERE

I SOLATOR

BREAK GLASSPRESS HERE

F IRE

I SOLATOR

F I RE

PRESS HERE

BREAK GLASS

HAZARDOUS AREA

PRESS HERE

BREAK GLASS

F IREA1445

A1445A1444/ 7

A1445

APOLLO

A1446

A1444

A1445

TRANSLATOR

EXTINGUISHING

SYSTEM

CONVENTIONAL

FIRE PANEL

FIRE DAMPER

MONITORING

BEAM DETECTOR

RELAY OUTPUT UNIT

MINI SWITCH MONITOR

WITH INTERRUPT

REMOTE INDICATOR

BARRIER

BARRIER

ZONE 1

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 7

ZONE 8

Discovery Panel HardwareDiscovery Panel Hardware

Fully programmable network comprising other Discovery and Voyager panels, graphics systems and network repeaters.

Fully programmable network comprising other Discovery and Voyager panels, graphics systems and network repeaters.

Up to 31 8-way panel enhancement boards may be added.

Two types are available:

1) fully-programmable inputs and relay outputs2) fully-programmable inputs and alarm outputs

Up to 31 8-way panel enhancement boards may be added.

Two types are available:

1) fully-programmable inputs and relay outputs2) fully-programmable inputs and alarm outputs

Up to 14 fully functional repeater panels may be connected via RS485 cable.

Up to 14 fully functional repeater panels may be connected via RS485 cable.

Individual panels and Integra networks are programmable via Windows PC package.

Individual panels and Integra networks are programmable via Windows PC package.

Page 5: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

Mechanical AssemblyMechanical Assembly

Motherboard and power supply located on a

removable chassis to assist cabinet installation.

Motherboard and power supply located on a

removable chassis to assist cabinet installation.

Zonal LEDs and optional printer are

located on the display board.

Zonal LEDs and optional printer are

located on the display board.

Motherboard holds up to 4 loop cards

Motherboard holds up to 4 loop cards

Space for internal 12Ah battery set.

Space for internal 12Ah battery set.

LPC approved high specification

switch mode power supply.

LPC approved high specification

switch mode power supply.

Display assembly

located on the removable door.

Display assembly

located on the removable door.

Page 6: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

Cabinet OptionsCabinet Options

For details of panel dimensions

see Application Guide.

For details of panel dimensions

see Application Guide.

Surface Cabinets

Cabinet colour reference is: RAL 7035 textured (Light Grey)

All cabinets are manufactured from sheet steel and finished in satin texture epoxy powder stove paint.

Semi-Flush Cabinets

The semi-flush bezel locates to the rear of the bevelled edge of the back box, leaving the bevelled edge and door raised out from the wall.

It is finished in the same colour as the back box and is fitted by means of pinch bolts, thus avoiding the need to drill the cabinet.

Fully Flush Cabinet (Illustrated)

Custom-made to a high quality, full-flush bezels are available in brass, stainless steel, or painted.This option is achieved by fixing a flat bezel assembly to the standard back box, replacing the standard door. The panel comes with assembly already fitted but may be supplied for later on-site fitting (this may be a little time-consuming).

Surface Cabinets

Cabinet colour reference is: RAL 7035 textured (Light Grey)

All cabinets are manufactured from sheet steel and finished in satin texture epoxy powder stove paint.

Semi-Flush Cabinets

The semi-flush bezel locates to the rear of the bevelled edge of the back box, leaving the bevelled edge and door raised out from the wall.

It is finished in the same colour as the back box and is fitted by means of pinch bolts, thus avoiding the need to drill the cabinet.

Fully Flush Cabinet (Illustrated)

Custom-made to a high quality, full-flush bezels are available in brass, stainless steel, or painted.This option is achieved by fixing a flat bezel assembly to the standard back box, replacing the standard door. The panel comes with assembly already fitted but may be supplied for later on-site fitting (this may be a little time-consuming).

Page 7: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

User ControlsUser Controls

The backlit LCD display gives information of

loop, device and zone number,

device type and event condition, together with a user-definable

text description.

The backlit LCD display gives information of

loop, device and zone number,

device type and event condition, together with a user-definable

text description.

System LED indications are

provided in addition to the LCD display.

System LED indications are

provided in addition to the LCD display.

The text descriptions give

the user clear, easy-to use functional controls.

The text descriptions give

the user clear, easy-to use functional controls.

The engineer accesses panel configuration

functions using the numerical

designations. The menu structure on

the LCD display guides the

engineer through the different set-up

facilities.

The engineer accesses panel configuration

functions using the numerical

designations. The menu structure on

the LCD display guides the

engineer through the different set-up

facilities.

Page 8: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

LCD DisplayLCD Display

The device types which may be indicated are as follows:

SOU - Loop sounder/sounder circuit controller

O/S - Input/Output deviceION - Ionisation smoke sensorMON - Monitor (zone monitor, control

monitor) OPT - Optical smoke sensor HEAT

- Heat sensorBGU - Call point or call point monitor

The device types which may be indicated are as follows:

SOU - Loop sounder/sounder circuit controller

O/S - Input/Output deviceION - Ionisation smoke sensorMON - Monitor (zone monitor, control

monitor) OPT - Optical smoke sensor HEAT

- Heat sensorBGU - Call point or call point monitor

Page 9: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

Zone IndicationsZone Indications

The printer slot and printer

location studs are available for easy

printer fitting

The printer slot and printer

location studs are available for easy

printer fitting

The Discovery panel is

available with or without the slide in zone

indication chart

The Discovery panel is

available with or without the slide in zone

indication chart

System LED indications are

provided in addition to the LCD display.

System LED indications are

provided in addition to the LCD display.

Page 10: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

PrinterPrinter

Hinged access to allow easy ribbon

change.

Hinged access to allow easy ribbon

change.

This good quality printer uses a reliable Epson

mechanism.

This good quality printer uses a reliable Epson

mechanism.

Designed for easy replacement of the paper roll

onto the carrier.

Designed for easy replacement of the paper roll

onto the carrier.

This button advances the

paper.

This button advances the

paper.

Open access to feed paper

through mechanism.

Open access to feed paper

through mechanism.

Engineer’s printer test button.

Engineer’s printer test button.

Page 11: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

A1535 8 Way Relay Board A1535 8 Way Relay Board

RS485 comms from panel

motherboard.

RS485 comms from panel

motherboard.

8 inputs may be normally open or

normally closed and will register as fire or non-fire on the panel as configured. Inputs

are fully programmable via the

panel or PC cause/effect.

8 inputs may be normally open or

normally closed and will register as fire or non-fire on the panel as configured. Inputs

are fully programmable via the

panel or PC cause/effect.

24V DC power.24V DC power.

8 x 1Amp changeover relay

outputs may be fully programmed via the

panel or PC cause/effect programme.

8 x 1Amp changeover relay

outputs may be fully programmed via the

panel or PC cause/effect programme.

Engineer’s DIL switches to set board address, enable O/C

or S/C inputs and disable

inputs/outputs.

Engineer’s DIL switches to set board address, enable O/C

or S/C inputs and disable

inputs/outputs.

Engineer’s links to disable functions

for set-up or maintenance

purposes.

Engineer’s links to disable functions

for set-up or maintenance

purposes.

Page 12: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

A1536 8 Way Alarm BoardA1536 8 Way Alarm Board

Engineer’s buzzer disable link for set-up or maintenance

purposes.

Engineer’s buzzer disable link for set-up or maintenance

purposes.

8 x 1Amp two-stage alarm

outputs may be fully programmed via the panel or PC cause/effect.

8 x 1Amp two-stage alarm

outputs may be fully programmed via the panel or PC cause/effect.

Engineer’s DIL switches to isolate

alarm outputs individually.

Engineer’s DIL switches to isolate

alarm outputs individually.

8 normally open inputs which will register as fire or

non-fire on the panel as

configured. Inputs are fully programmable via panel or PC

cause/effect.

8 normally open inputs which will register as fire or

non-fire on the panel as

configured. Inputs are fully programmable via panel or PC

cause/effect.

24V DC power.24V DC power.

Test alarms when switched

to 0V.

Test alarms when switched

to 0V.

Alarm Fault LEDs.

Alarm Fault LEDs.

RS485 comms from panel

motherboard.

RS485 comms from panel

motherboard.

Engineer’s DIL switches to set board address, disable

inputs and outputs, test LEDs and test alarms.

Engineer’s DIL switches to set board address, disable

inputs and outputs, test LEDs and test alarms.

Page 13: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

Extensive User’s MenuExtensive User’s Menu

User Functions•Time/Date•Delay

•Delay Enable/Disable•Day/Night Modes

•Enable Day/Night/Auto/Off•Enable/Disable

•Devices•Zones•Printer•Sounders

•View•View Event Log•View Suppressed Events

•Test•Point Walk Test•Alarm Walk Test

•Print•Clear Print Queue•Print Event Log•Print Disablements

User Functions•Time/Date•Delay

•Delay Enable/Disable•Day/Night Modes

•Enable Day/Night/Auto/Off•Enable/Disable

•Devices•Zones•Printer•Sounders

•View•View Event Log•View Suppressed Events

•Test•Point Walk Test•Alarm Walk Test

•Print•Clear Print Queue•Print Event Log•Print Disablements

User function to operate one man device test and alarm audibility test.

User function to operate one man device test and alarm audibility test.

User function to select the DAY mode, NIGHT mode, AUTO mode via timer, or OFF (XP95 default settings).

User function to select the DAY mode, NIGHT mode, AUTO mode via timer, or OFF (XP95 default settings).

User function to read the output delay and to enable or disable its operation.

User function to read the output delay and to enable or disable its operation.

User functions to disable individual loop devices, a range of devices, full zones, the printer and sounders.

User functions to disable individual loop devices, a range of devices, full zones, the printer and sounders.

Page 14: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

Overview of the Engineer’s MenuOverview of the Engineer’s Menu

1. PANEL SETUP1. LOOP SETUP

1. Loop Configuration

1. Loop Contents1. View Loop Contents

2. Print Loop Contents

1. Reconfigure Loop

2. Device Sensitivity (XP95/Discovery)

1. Fire

2. Alert

3. Discovery1. Print Drift

2. Print Date

3. LED

4. Rapid Compensation

2. Zone Allocation

1. Edit Device Zones

2. Print Device Zones

3. View Device Zones

1. PANEL SETUP1. LOOP SETUP

1. Loop Configuration

1. Loop Contents1. View Loop Contents

2. Print Loop Contents

1. Reconfigure Loop

2. Device Sensitivity (XP95/Discovery)

1. Fire

2. Alert

3. Discovery1. Print Drift

2. Print Date

3. LED

4. Rapid Compensation

2. Zone Allocation

1. Edit Device Zones

2. Print Device Zones

3. View Device Zones

3. Loop Cause Effect1. Device Group Allocation

1. Edit Device Groups2. Print Device Groups3. View Device Groups

2. Loop Output C/E3. Print Loop O/P C/E

2. I/O SETUP1. Remote Evacuate Mode

2. TEXT EDIT1. EDIT COMPANY NAME2. EDIT Device TEXT

3. Loop Cause Effect1. Device Group Allocation

1. Edit Device Groups2. Print Device Groups3. View Device Groups

2. Loop Output C/E3. Print Loop O/P C/E

2. I/O SETUP1. Remote Evacuate Mode

2. TEXT EDIT1. EDIT COMPANY NAME2. EDIT Device TEXT

Page 15: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

Windows-based PC ProgrammingWindows-based PC Programming

Windows-based PC programming package for panel set up, zones, text, local and network cause/effect, Discovery mode types, sensitivity levels and day/night timings.

Windows-based PC programming package for panel set up, zones, text, local and network cause/effect, Discovery mode types, sensitivity levels and day/night timings.

Page 16: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

Discovery Mode-change MapsDiscovery Mode-change Maps

The discovery panel provides the engineer with the

facility to set a mode sensitivity map for:

• Day use - for example, less sensitive in some process areas during working hours

•Night use - for example, maximum sensitivity throughout entire building when not in use

•Default - ignore day/night sensitivity maps, set to XP95 equivalent

The engineer may set up each device into a day map, and night map, and set the clock (week day or weekend options) to switch between them

Page 17: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

Discovery Mode-change MapsDiscovery Mode-change Maps

The end user may easily select between:

•Day mode - manually holds all devices in the Day mode

setting

•Night Mode - Manually holds all devices in Night mode

setting

•Automatic - Day/Night mode determined by clock

•Off - To manually set all devices to default (XP95 equivalent)

Page 18: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

Discovery Temporary Mode ChangesDiscovery Temporary Mode Changes

Loop outstation inputs may be configured to change Discovery Multi-sensor modes.

Applications: -

•Loading Bays - As a lorry enters, smoke detection may be

temporarily disabled

•Theatre Stages - Stage hand may operate key switch to

de-activate smoke detection at performance times

•Hotel Function Rooms - Keyswitch at room entrance to

disable smoke detection during special events

•Smoke Cloak Security - Multisensor smoke elements

may be disabled when the smoke cloak is activated

Page 19: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

Networking Networking

• “All talk - selective listen”• No Master panel or P.C. required and thus no

single Device of failure • Up to 15 active panels or 60 loops may be

networked together plus an additional 17 passive nodes

• Discovery panels, Voyager panels, network repeaters and Alarm Manager graphics systems

• Conventional panels, extinguishant panels and other equipment via network repeater and/or loop I/O

• Full event and cause/effect programming across network

• RS485 data communications• Network repeater with up to 248 programmable

inputs and 248 programmable outputs

Page 20: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

Typical Network Illustration Typical Network Illustration

RS485 network comms.

RS485 network comms.

RS485 comms to panel repeaters and expansion cards.

RS485 comms to panel repeaters and expansion cards.

Engineer’s programming via PC.

Engineer’s programming via PC.

Network repeater with up to 248 programmable inputs and 248 programmable outputs.

Network repeater with up to 248 programmable inputs and 248 programmable outputs.

Discovery, and Voyager panels may be networked together with Network Repeaters, Alarm Managers (Graphics) PCs.

Discovery, and Voyager panels may be networked together with Network Repeaters, Alarm Managers (Graphics) PCs.

Page 21: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

ZONE 1

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 7

ZONE 8

Network RepeaterNetwork Repeater

The LCD provides user and engineer facilities. Devices

may be isolated across the network

via this network repeater.

The LCD provides user and engineer facilities. Devices

may be isolated across the network

via this network repeater.

A typical application shows the 8 way boards linked to

fireman's controls, LED’s, alarm

sounders and plant shut down.

A typical application shows the 8 way boards linked to

fireman's controls, LED’s, alarm

sounders and plant shut down.

Up to 31 8-way panel enhancement boards may be added to the Integra Network Repeater. All inputs and outputs are programmable across the network.

Two types are available:

1) fully-programmable inputs and relay outputs2) fully-programmable inputs and alarm outputs

Up to 31 8-way panel enhancement boards may be added to the Integra Network Repeater. All inputs and outputs are programmable across the network.

Two types are available:

1) fully-programmable inputs and relay outputs2) fully-programmable inputs and alarm outputs

Page 22: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

Alarm Manager Alarm Manager

The drawings are inserted as bitmaps and may be copied from CAD and

edited within Windows.

The drawings are inserted as bitmaps and may be copied from CAD and

edited within Windows.

User controls are configured if required via password set-up. Multi-level password

protection may be configured for each type

of function.

User controls are configured if required via password set-up. Multi-level password

protection may be configured for each type

of function.

The site procedure pages give user

instructions for each type of event.

The site procedure pages give user

instructions for each type of event.

This is a mouse or touch-screen driven system that does not require keyboard

after set-up.

This is a mouse or touch-screen driven system that does not require keyboard

after set-up.

The event priority and thus its display colour are determined by the nature of the event.

The event priority and thus its display colour are determined by the nature of the event.

Instantly accessible current

event log.

Instantly accessible current

event log.

The Alarm Manager (graphics system) may be

individually tailored to customer’s requirements

and is configured with password protection.

The Alarm Manager (graphics system) may be

individually tailored to customer’s requirements

and is configured with password protection.

Up to 5 map pages may be allocated for each

individual device on the network (4 allocated

here). Map pages may be used for drawings or

specific instructions as required.

Up to 5 map pages may be allocated for each

individual device on the network (4 allocated

here). Map pages may be used for drawings or

specific instructions as required.

Page 23: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

Typical Radio Pager ConfigurationTypical Radio Pager Configuration

The radio pager system, when connected to the control panel, can be used to transmit both text and numeric messages direct to pocket pagers.

Pagers will display Fire / Fault conditions including Sensor location text. Up to 9,999 pagers can be connected to system.

The radio pager system, when connected to the control panel, can be used to transmit both text and numeric messages direct to pocket pagers.

Pagers will display Fire / Fault conditions including Sensor location text. Up to 9,999 pagers can be connected to system.

Connection to panel (printer or PC port, dependent upon panel).

Connection to panel (printer or PC port, dependent upon panel).

Interface boardInterface board

Opto isolatorOpto isolator

TransmitterTransmitter

Page 24: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

XP95 Test ToolXP95 Test Tool

The XP95 Test Tool is an engineer’s tool to assist with commissioning and fault finding on XP95 loop systems.

Loop configurations and the status of each device may be interrogated, device LEDs may be turned on/off. The test tool may be connected to an entire loop without the panel connected or connected to individual

devices around the circuit.

The XP95 Test Tool is an engineer’s tool to assist with commissioning and fault finding on XP95 loop systems.

Loop configurations and the status of each device may be interrogated, device LEDs may be turned on/off. The test tool may be connected to an entire loop without the panel connected or connected to individual

devices around the circuit.

Alpha-numeric LCD display.

Alpha-numeric LCD display.

Engineer’s keypad.

Engineer’s keypad.

On/off switch and LED indication.

On/off switch and LED indication.

Battery charger socket.

Battery charger socket.

Sockets for flying leads to connect to loop and/or

individual XP95 devices.

Sockets for flying leads to connect to loop and/or

individual XP95 devices.

Page 25: Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices.

More About ProgrammingMore About Programming

• For more about the Windows-based, full upload/download PC software package click here