The Zonri's single break, insulator operated disconnector has been designed for both rural distribution and
substation type disconnector applications and complying with IEC 60129.Rated voltage from 12kV to 36kV,rated
current up to 1200A.
19 20
Three phase disconnect switch
Features
Technical parameters:
GW58-12/24/36 outdoor MV disconnect switch are used to
open an close circuit with voltage but no-load 50/60Hz,12kV
up to 36kV power system, this anti-pollution type can be used
in the series pollution area.
Manufacture according IEC standards.
Up to 36kV,900A,200kV BIL.
Three phase disconnector.
Porcelain and polymer type insulator.
Manual and electric drivers.
Accessories and relays.
Test Item
Rated voltage
Rated current
Rated frequency
Rated short-time withstand current
Rated short-circuit duration
Main loop resistance
Power frequency withstand (wet)
Power frequency withstand (ydr)
Lightning impulse withstand voltage.
Mechanical life
Unit Data
kV
A
Hz
kA
s
ìÙ
kV
kV
kV
Times
12
400/630
50/60
20
4
100
30
48
75
2000
24
400/630
50/60
20
4
100
65
85
125
2000
36
400/630
50/60
25
4
100
85
115
185
2000
Disconnectors
21
Technical specifications
Type
Rated Voltage kV
Rated Current A
Momentany Current A
BIL kV
Short Time Withstand
Current 2S(Sym)A
GW9-15/400
15
400
40000
125
25000
GW9-15/630
15
630
40000
125
2500
GW9-15/900
15
900
40000
125
2500
15KV
Type
Rated Voltage kV
Rated Current A
Momentany Current A
BIL kV
Short Time Withstand
Current 2S(Sym)A
GW9-24/400
24
400
40000
125
25000
GW9-24/630
24
630
40000
125
2500
GW9-24/900
24
900
40000
125
2500
24KV
Type
Rated Voltage kV
Rated Current A
Momentany Current A
BIL kV
Short Time Withstand
Current 2S(Sym)A
GW9-36/400
36
400
40000
125
25000
GW9-36/630
36
630
40000
125
2500
GW9-36/900
36
900
40000
125
2500
36KV
Three phase disconnect switch
Technical specifications
Technical specifications
FZW33 12kV/24kV Outdoor AC vacuum type load disconnector is a new product adopts domestic existing mature load
breaker switch product ion experience and overseas advanced technology to design and manufacture. The load
breaker is composed of disconnect blade, vacuum interrupter and operation mechanism. vacuum extinguishing arc,
there are merits as strong extinguishing arc ability, reliable performance, long lifetime, small volume, no explosive danger
and no pollution to environment.
These disconnectors are suitable for powering networks of 12,24kV,to be used as a disconnecting devive of MV/LV
distribution transformers and to disconnect the MV outdoor tine.
It accords with the standards of IEC62271-102 & GB/T3804:3.6~40.5kV High voltage switches, IEC60694 &
GB/T11022: High voltage switch apparatus and control apparatus.
Vacuum Type Load Disconnector
Ambient condition
1. Altitude: 1000m;
2. Ambient temperature: -35 ~+50 C ;
3. Relative humidity: daily average 90%; monthly average 95%;
4. Earthquake intensity: 8 degree;
5. Applicable occasions should be free from inflammable, explosives and severe vibration.
Technical specification
No .
1
2
3
4
5
6
7
8
9
11
12
13
14
15
16
17
18
Test Item
10
Vacuum arc extinguish chamber
No .
1
2
3
4
Item
19
20
Rated voltage
Rated current
Rated frequency
Rated short-time withstand current
Rated short-circuit duration
Rated active load breaking current
Rated loop breaking current
Rated cable charging current
5% rated active load breaking current
Rated short-circuit making current
Main loop resistance
power frequency withstand voltage against the earth, between phases
power frequency withstand voltage against the isolating distance
Lightning impulse withstand voltage against the earth, between phases (peak)
Lightning impulse withstand voltage against the air gap(peak)
Mechanical life
Three phase closing asynchronous
Main contact blade pressure
Distance between electric parts and phase to earth
Rated operating force
kV
A
Hz
kA
s
A
A
A
A
kA
kV rms
kV rms
kV
kV
Times
ms
N
mm
N
12
400/630
50/60
20
4
400/630
400/630
12
31.5
50
100
40
48
75
85
10000
5
520
300
300
Unit Data
24
400/630
50/60
20
4
400/630
400/630
12
31.5
50
100
65
79
125
145
10000
5
520
600
300
Contact distance
Average breaking speed
Three phase breaking asynchronous
Three phase making asynchronous
DataUnit
mm
m/s
ms
ms
10 1
1.2 0.2
<3
<3