Transcript of Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
1/48
November 2015
Reference Architecture Guide
Disaster Recovery using Hitachi Universal Replicator
on Hitachi Unified Compute Platform for the SAPHANA Platform using Hitachi Compute Blade 2500,
Hitachi Virtual Storage Platform G1000, and Hitachi
NAS Platform 4060
Abhishek DhanukaBy
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
2/48
Feedback
Hitachi Data Systems welcomes your feedback. Please share your thoughts by sending an email message to
[email protected]. To assist the routing of this message, use the paper number in the subject and the title of this white
paper in the text.
mailto:[email protected]?subject=Document%20AS-440-00%20mailto:[email protected]?subject=Document%20AS-440-00%20
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
3/48
Contents
Solution Overview................................................................................................................ 3
Hardware Elements......................................................................................................................... 7
Software Elements ........................................................................................................................ 11Solution Design................................................................................................................... 12
Hitachi Compute Blade 2500 Chassis Configuration ................................................................... 12
520X B2 Server Blade Architecture .............................................................................................. 14
Fibre Channel SAN Architecture ................................................................................................... 14
Storage Architecture ..................................................................................................................... 15
Hitachi NAS Platform 4060 Architecture....................................................................................... 23
Network File System Design for Shared Binaries ......................................................................... 25
Management Server...................................................................................................................... 26
Network Architecture .................................................................................................................... 27SAP Storage Connector API Fibre Channel Client ....................................................................... 33
Journal Sizing................................................................................................................................ 33
Inter-site Configuration ................................................................................................................. 35
Disaster Recovery and Replication Components ......................................................................... 36
Engineering Validation...................................................................................................... 43
Test Methodology ......................................................................................................................... 43
Test Results .................................................................................................................................. 43
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
4/48
1
1
Disaster Recovery using Hitachi Universal Replicator on Hitachi
Unified Compute Platform for the SAP HANA Platform using
Hitachi Compute Blade 2500, Hitachi Virtual Storage Platform
G1000, and Hitachi NAS Platform 4060Reference Architecture Guide
This reference architecture guide depicts the necessary components and overall layout of a disaster recovery solution
using Hitachi Universal Replicator on Hitachi Unified Compute Platform for the SAP HANA platform (UCP) in a scale-out
configuration. This guide documents how to deploy this configuration using the following:
Hitachi Compute Blade 2500 (CB 2500) chassis with 520X B2 server blades
Quanta Cloud Technology QuantaPlex T41S-2U server with one node
Hitachi Virtual Storage Platform G1000 (VSP G1000)
Hitachi NAS Platform 4060 (HNAS 4060)
System management unit
Hitachi Universal Replicator (HUR)
SAP HANA
Two operating systems:
SUSE Linux Enterprise Server for SAP Applications
Red Hat Enterprise Linux (Alternate)
The testing of this solution in the lab was only on a 2+1 configuration. However, this reference architecture supports the
scale-out configurations as listed in Hitachi Unified Compute Platform for the SAP HANA Platform using 3 TB SAP HANA
Nodes in a Scale-out 48 TB Configuration of 16 Active Nodes and 3 Standby Nodes with Hitachi Compute Blade 2500
Chassis, 520X B2 Server Blades, and Hitachi Virtual Storage Platform G1000 Reference Architecture Guide (AS-399-02).
For information concerning your implementation, please contact your GSS representative for more details.
This document supports understanding the example architecture of disaster recovery using Hitachi Universal Replicator
on Unified Compute Platform for SAP HANA in a scale-out configuration.
The scale out environment for Unified Compute Platform for SAP HANA is a preconfigured analytical appliance that
provides real-time access to operational data for use in analytic models. Changes to this architecture require approval
from the following at Hitachi Data Systems:
Sales
Solution Engineering and Technical Operations
Solution product management
https://www.hds.com/assets/pdf/hitachi-ucp-for-sap-hana-with-compute-blade-2500-and-vsp-g1000.pdfhttps://www.hds.com/assets/pdf/hitachi-ucp-for-sap-hana-with-compute-blade-2500-and-vsp-g1000.pdfhttps://www.hds.com/assets/pdf/hitachi-ucp-for-sap-hana-with-compute-blade-2500-and-vsp-g1000.pdfhttps://www.hds.com/assets/pdf/hitachi-ucp-for-sap-hana-with-compute-blade-2500-and-vsp-g1000.pdfhttps://www.hds.com/assets/pdf/hitachi-ucp-for-sap-hana-with-compute-blade-2500-and-vsp-g1000.pdfhttps://www.hds.com/assets/pdf/hitachi-ucp-for-sap-hana-with-compute-blade-2500-and-vsp-g1000.pdf
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
5/48
2
2
Failure of SAP HANA results in revenue loss. For protection from this loss, use two sites in the disaster recovery strategy.
In addition to failover production, the second site can handle the quality assurance environment of the SAP HANA
landscape.
The primary business problem this solution answers is disaster recovery for SAP HANA. This solution performs
asynchronous replication of SAP HANA data volumes and log volumes on Hitachi Virtual Storage Platform G1000 to the
secondary site. It also performs asynchronous replication of the SAP HANA binaries and other configuration files stored in
the /hana/shared file system on Hitachi NAS Platform 4060 to the secondary site.
Data centers at each site must have almost identical hardware for this disaster recovery solution. Implementing Hitachi
Universal Replicator on this environment permits the additional use of the secondary site as a quality assurance
environment. This additional use requires adding additional disk drives on the secondary site storage to run the quality
assurance system.
Hitachi Virtual Storage Platform G1000 technology permits maintaining sufficient performance for the SAP HANA
production instance and site-to-site replication.
This technical paper assumes you have familiarity with the following:
Storage area network-based storage systems
Network attached storage (NAS) systems
General storage concepts
General storage replication skills and concepts
General network and virtual IP knowledge
General WAN knowledge
Advanced SAP HANA skills
Disaster Recovery scenarios
Common IT storage practices
Note — Testing of this configuration was in a lab environment. Many things affect production environments beyond
prediction or duplication in a lab environment. Follow the recommended practice of conducting proof-of-concept
testing for acceptable results in a non-production, isolated test environment that otherwise matches your production
environment before your production implementation of this solution.
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
6/48
3
3
Solution OverviewThe primary site A contains a production SAP HANA database instance. Implement this site as a scale-out configuration
of Hitachi Unified Compute Platform for the SAP HANA platform.
The secondary site is an exact replica of primary site, with the exception of optional additional storage disks. Site B
houses the following:
Failover production instance
(Optional) Non-production instances, such as the following that requires additional disks:
Quality assurance
Development
Test, In-memory database of SAP HANA.
The design of the SAP HANA in-memory database enables this solution to use the same set of Hitachi Compute Blade
2500 nodes for production and non-production instances.
In the test environment for this solution, the Hitachi Virtual Storage Platform G1000 at the secondary site housed two setsof disks for data, log, and /hana/shared LUNs for the following:
The replicated production instance
(Optional) The quality assurance system
In this solution, install command control interface on the management servers on the primary site and secondary site,
which performs the data replication operations within Hitachi Virtual Storage Platform G1000 at each site using Hitachi
Open Remote Copy Manager instances. Each instance at the primary site and secondary site management server has its
own Hitachi Open Remote Copy Manager configuration file that lists the following for replication between two sites:
SAP HANA data volumes
SAP HANA log volumes
Hitachi NAS Platform LUNs
Hitachi Virtual Storage Platform G1000 works with Hitachi Universal Replicator software to enable SAP HANA disaster
recovery. This solution uses a Fibre Channel over IP (FCIP) switch for the wide area network connections between each
Virtual Storage Platform G1000 at the primary site and the secondary site. Take the options for long distance data
replication in the landscape using the pre-existing enterprise network infrastructure and service provider into
consideration for the SAP HANA disaster recovery setup.
With Hitachi Universal Replicator, updates on the SAP HANA nodes to the primary production volume on the primary site
Virtual Storage Platform G1000 are copied to a local journal volume at primary site storage. The secondary site Virtual
Storage Platform G1000 “pulls” data from the primary site journal volume across the inter-site wide area network
connection to the secondary volume. The local system is free to perform its role as a transaction processing resourcerather than as a replication engine.
For the asynchronous replication of Hitachi NAS Platform LUNs hosting the /hana/shared file system on Virtual Storage
Platform G1000, perform a one-time initial configuration after completing the initial pair copy operations to configure the
RAID mirror relationships between the NAS Platform LUNs at both sites. Make the NAS Platform clusters at both the sites
aware of the Universal Replicator LUN relationship between them during this initial configuration by using the RAID
mirroring command (sd-mirror-remotely).
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
7/48
4
4
In case of an outage or any component failure in the primary site, an administrator initiates a manual failover to the
secondary site using customized scripts. There are two different possibilities for enabling client connection recovery,
using either virtual IP failover or DNS failover configuration. The actual implementation differs, based on the network and
cluster management capabilities.
This solution supports the following four different disaster recovery options.
1. Add a Disaster Recovery Site
This option is for a primary site for production and a secondary site for disaster recovery.
2. Add a Quality Assurance or Development Instance
This option is for a primary site for production and a secondary site for disaster recovery site and a single quality
assurance or development SAP HANA instance.
3. Disaster Recovery Connectivity Bundle
This option is for a Fibre Channel over IP (FCIP) switch between two sites.
4. Only Disaster Recovery Site
This option is for adding a secondary site for a disaster recovery solution to an existing SAP HANA landscape. (The
primary site for production already exists.)
To perform the replication of Hitachi Unified Compute Platform for the SAP HANA platform, the reference solution uses
the following:
Hitachi Compute Blade 2500 with 520X B2 Server Blades
Quanta Cloud Technology QuantaPlex T41S-2U Server
An ultra-dense design equipped with four independent nodes, it creates the flexibility to set up different workloads
independently in one 2U shared infrastructure, providing optimal data center performance. This solution uses only one
node out of the four nodes.
Hitachi Virtual Storage Platform G1000
This is a storage platform that scales for all data types that flexibly adapts for performance, capacity, and multi-
vendor storage.
Hitachi NAS Platform 4060
This is a network-attached storage solution used for file sharing, file server consolidation, data protection, and
business-critical NAS workloads.
System management unit software
Providing front-end server administration and monitoring tools for Hitachi NAS Platform, this supports clustering and
acting as a quorum device in a cluster.
Hitachi Universal Replicator
With asynchronous replication over any distance, this provides for business continuity, optimization of resource
usage, and improves efficiency as well as resilience.
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
8/48
5
5
SAP HANA Platform
This is a multi-purpose, in-memory database appliance to analyze transactional and analytical data.
Brocade VDX 6740-48 Switch
This 48-port switch provides 10 GbE connectivity to the appliance.
Brocade ICX 6430-48 Switch
This 48-port 1 GbE switch provides management network to the appliance.
Brocade ICX 6430-24 Switch
A 24-port 1 GbE switch that provides a NAS platform private network
Brocade 7800 Extension Switch
Providing up to sixteen 8 Gb/sec Fibre Channel ports and six 1 Gigabit Ethernet (GbE) ports for scalable bandwidth,
port density, and throughput, this switch extends and optimizes storage area network (SAN) fabric connectivity over a
distance to support business continuity and disaster recovery applications.
The Brocade 7840 switch can also be used instead of the Brocade 7800 switch. The 7840 switch has 24 ports of
auto-sensing 2 Gb/sec, 4 Gb/sec, 8 Gb/sec, and 16 Gb/sec interfaces in a single 2U enclosure.
Figure 1 on page 6 shows the configuration of this solution.
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
9/48
6
6
Figure 1
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
10/48
7
7
Hardware Elements
Table 1 describes the hardware used to deploy a three active nodes and one standby node configuration at each site. All
the configurations of Hitachi Unified Compute Platform for the SAP HANA Platform support Hitachi Universal Replicator.
Table 1. Hardware Elements
Hardware Quantity Configuration Role
Hitachi Compute Blade
2500 chassis
4 8 server blade chassis
2 management modules
10 cooling fan modules
5 power supply modules
2 × FIVE-FX 16 Gb/sec 2-port
Fibre Channel PCI-Ex card for
each SAP HANA node
4 × 2-port 10GBASE-SR PCI-
Ex card for each SAP HANA
node
Server blade chassis.
One chassis is required
for two SAP HANA
nodes.
520X B2 server blade 24 2 × 18-core processors
768 GB RAM
2 pass through mezzanine card
on Mezzanine Slot 2 and Slot 4
of each server blade, except for
Server Blade 15
Server blade for the SAP
HANA nodes.
Four server blades are
required for each SAP
HANA node.
SMP connection board for
520X server blade
6
4 server blade SMP connectionboard
SMP expansion module
SMP connector cover
SMP connector turns four
physical blades into one
SAP HANA node with 8 ×
18-core processors and 3
TB of memory.
One SMP connector is
required per SAP HANA
node.
Hitachi NAS Platform 4060 4 For each NAS Platform server
2 cluster ports
2 × 10 Gb ports
2 Fibre Channel ports
2 Ethernet ports
Provide NFS shared file
system for the following:
SAP HANA binaries
Cluster-wide
configuration files
Storing one in-memory
backup
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
11/48
8
8
System management unit
software
2 2 Intel Core 2 Duo E7500
processor, 2.93 GHz CPU,
4 GB RAM
NAS Platform cluster
management
Hitachi Virtual StoragePlatform G1000
2 MPB - 2 pairs
DKA (BED) - 2 pairs
CHA (FED) - 3 pairs
Block storage for SAPHANA nodes and NAS
Platform
Quanta Cloud Technology
QuantaPlex T41S-2U server
2 For T41S-2U server:
Intel Xeon E5-2620 v3
processor, 2.4 GHz CPU,
32 GB RAM
2 × 500 GB 7200 RPM SATA
drives
1 dual port 10GbE Intel
82599ES SFP+OCP mezzanine
card
1 dual port 1 GbE Base-T Intel
i350 mezzanine card
Emulex Dual Port 8 Gb/sec
Fibre Channel HBA
Management server runs
the following:
NTP
Hitachi Command Suite
Hitachi Hi-Track Remote
Monitoring system
SAP HANA Studio
Command control
interface
Brocade VDX 6740-48 port
switch
8 Two distinct VLANs, each
dedicated to NFS and SAP
HANA inter-cluster network
Two switches with one VLAN to
provide uplink network to local
area network infrastructure
10 GbE NFS and inter-
cluster network
10 GbE client network
Brocade ICX 6430-48 port
switch
2 1 GbE
48 ports
1 GbE Management
Network
Brocade ICX 6430-24 port
switch
2 1 GbE
24 ports
NAS Platform private
network
Brocade 7800 switch 4
16 x 8Gb/sec Fibre Channel
6 x 1 GbE FCoE Switch
FCoE switch for storage
connections
Table 1. Hardware Elements (Continued)
Hardware Quantity Configuration Role
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
12/48
9
9
Hitachi Compute Blade 2500
Hitachi Compute Blade 2500 delivers enterprise computing power and performance with unprecedented scalability and
configuration flexibility. Lower your costs and protect your investment.
Flexible I/O architecture and logical partitioning allow configurations to match application needs exactly with Hitachi
Compute Blade 2500. Multiple applications easily and securely co-exist in the same chassis.
Add server management and system monitoring at no cost with Hitachi Compute Systems Manager. Seamlessly integrate
with Hitachi Command Suite in Hitachi storage environments.
This configuration uses 24 520X B2 server blades in the Hitachi Compute Blade 2500 chassis. Table 2 has the
specifications for the 520X B2 server blades used in this solution.
Table 2. 520X B2 Server Blade Configuration
Feature Configuration
Processors Intel Xeon processor E7-8880
2 processors per server blade
Processor SKU Intel Xeon processor E7-8880 v3
Processor frequency 2.3 GHz
Processor cores 18 cores
Memory DIMM slots 48 slots populated
Memory 768 GB RAM
16 GB DIMMs
Network ports 1 USB 3.0 port
KVM connector (VGA, COM, USB 2.0 2-port)Other interfaces
Intel Xeon processor E7-8880
2 processors per server blade
http://www.hds.com/products/compute-blade/compute-blade-2500.htmlhttp://www.hds.com/products/compute-blade/compute-blade-2500.html
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
13/48
10
10
Hitachi NAS Platform 4060
Hitachi NAS Platform is an advanced and integrated network attached storage (NAS) solution. It provides a powerful tool
for file sharing, file server consolidation, data protection, and business-critical NAS workloads.
Powerful hardware-accelerated file system with multi-protocol file services, dynamic provisioning, intelligent tiering,
virtualization, and cloud infrastructure
Seamless integration with Hitachi SAN storage, Hitachi Command Suite, and Hitachi Data Discovery Suite for
advanced search and index
Integration with Hitachi Content Platform for active archiving, regulatory compliance, and large object storage for
cloud infrastructure
This solution uses NAS Platform 4060 servers for file system sharing of the global binary and configuration SAP HANA
files. There are four NAS Platform 4060 server nodes.
The system management unit provides front-end server administration and monitoring tools for NAS Platform. It supports
clustering and acts as a quorum device in a cluster.
Hitachi Virtual Storage Platform G1000
Hitachi Virtual Storage Platform G1000 provides an always-available, agile, and automated foundation that you need for acontinuous infrastructure cloud. This delivers enterprise-ready software-defined storage, advanced global storage
virtualization, and powerful storage.
Supporting always-on operations, Virtual Storage Platform G1000 includes self-service, non-disruptive migration and
active-active storage clustering for zero recovery time objectives. Automate your operations with self-optimizing, policy-
driven management.
The following reside on this storage device:
Operating system LUNs
Data LUNs
Log LUNs
LUNs for the Hitachi NAS Platform cluster
This solution uses two Hitachi Virtual Storage Platform G1000 storage platforms.
To properly size the storage, refer to Hitachi Unified Compute Platform for the SAP HANA Platform using 3 TB SAP HANA
Nodes in a Scale-out 48 TB Configuration of 16 Active Nodes and 3 Standby Nodes with Hitachi Compute Blade 2500
Chassis, 520X B2 Server Blades, and Hitachi Virtual Storage Platform G1000 Reference Architecture Guide (AS-399-02).
At any time, the secondary site only has one live SAP HANA instance. The secondary site is for production or quality
assurance. Normally the quality assurance instance is available for use at the secondary site in case of a service outage,
when it becomes the production instance.
Use the server priority manager at the secondary site to do the following:
Designate the prioritized ports (replication) and non-prioritized ports (quality assurance).
Set the upper limits and thresholds for the I/O activity of these ports to prevent low-priority activities from negatively
affecting the high priority activities, such as replication.
Additional information is available in the Hitachi Virtual Storage Platform G1000 Performance Guide.
http://www.hds.com/products/file-and-content/network-attached-storage/http://www.hds.com/products/storage-software/hitachi-command-suite.htmlhttp://www.hds.com/products/storage-software/data-discovery-suite.htmlhttp://www.hds.com/products/file-and-content/content-platform/http://www.hds.com/products/storage-systems/hitachi-virtual-storage-platform-g1000.html?WT.ac=us_mg_pro_hvspg1000http://www.hds.com/products/storage-systems/hitachi-virtual-storage-platform-g1000.html?WT.ac=us_mg_pro_hvspg1000http://www.hds.com/products/file-and-content/content-platform/http://www.hds.com/products/storage-software/data-discovery-suite.htmlhttp://www.hds.com/products/storage-software/hitachi-command-suite.htmlhttp://www.hds.com/products/file-and-content/network-attached-storage/
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
14/48
11
11
Software Elements
Table 3 describes the software products used to deploy this three active node and one standby node configuration.
Table 3. Software Elements
Software Version
Hitachi Storage Navigator Modular 2 Microcode dependent
SMU software 12.4.3924.05
Hitachi NAS Platform firmware 12.4.3924.11
Hitachi Universal Replicator Microcode dependent
Command control interface 01-34-03/04
Hitachi Dynamic Link Manager 8.0.1
Operating System
Used on Hitachi Compute
Blade 2500
SUSE Linux Enterprise Server for
SAP Applications
SUSE Enterprise Linux 11 SP3
Alternate: Red Hat Linux Enterprise RHEL 6.6
SAP HANA 1.0 SPS09, Rev. 97 or later
SAP HANA Studio 1.0 SPS09, Rev. 97 or later
Microsoft® Windows Server® 2012 R2
Used on QuantaPlex T41S-2U
Standard Edition
Brocade VDX 6740 port switch 4.1.3b or later
Brocade ICX 6430-48 port switch 7.4.00 or later
Brocade 7800/7840 switch 7.4.00 or later
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
15/48
12
12
Solution DesignThe detailed design for using Hitachi Universal Replicator with this Hitachi Unified Compute Platform for the SAP HANA
platform solution is based on specifications from SAP and is a 3+1 node configuration that includes the following:
“Hitachi Compute Blade 2500 Chassis Configuration,”
starting on page 12
“520X B2 Server Blade Architecture” on page 14
“Fibre Channel SAN Architecture,” starting on page 14
“Storage Architecture,” starting on page 15
“Hitachi NAS Platform 4060 Architecture,” starting on
page 23
“Network File System Design for Shared Binaries,”
starting on page 25
“Management Server,” starting on page 26
“Network Architecture,” starting on page 27
“SAP Storage Connector API Fibre Channel Client” onpage 33
“Journal Sizing,” starting on page 33
“Inter-site Configuration,” starting on page 35
“Disaster Recovery and Replication Components,”
starting on page 36
Hitachi Compute Blade 2500 Chassis Configuration
This solution uses four Hitachi Compute Blade 2500 chassis. Each chassis has of a total of eight 520X B2 server blades.
Each SAP HANA node is four server blades connected using a four-blade SMP interface connector. This means that each
chassis has two SAP HANA nodes.
The PCIe slots on each of the chassis have the following components.
One 2-port 10GBASE-SR PCI-Ex card for each of the following IOBD slots:
01B
03A
09B
11A
02A
04B
10A
12B
One FIVE-EX 16 Gb/sec 2-port Fibre Channel PCI-Ex card for each of the following IOBD slots:
01A
09A
04A
12A
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
16/48
13
13
Figure 2 shows the front and back view of Chassis 1 for Hitachi Compute Blade 2500. Use the same configuration for the
remaining chassis.
Figure 2
Table 4 on page 14 shows the Hitachi Compute Blade 2500 chassis configuration of all the SAP HANA nodes.
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
17/48
14
14
520X B2 Server Blade Architecture
This solution uses 12 520X B2 server blades for each node in the 3 TB SAP HANA configuration with two active nodes
plus one standby node for each disaster recovery site.
Each SAP HANA node has four server blades connected using the four-blade SMP interface connector. This creates a
single eight-socket SMP node with 144 cores and 3 TB of memory.
Table 5 lists the 3-node server blade configuration per site.
Fibre Channel SAN Architecture
Each of the 520X B2 server blades has a pass-through mezzanine card on Mezzanine Slot 2 and Mezzanine Slot 4. These
slots connect to the 16 Gb/sec Hitachi FIVE-FX Fibre Channel PCI-Ex card and to the 10GbE NIC card installed in the
PCI-Ex slots through the backplane within the server chassis.
For each SAP HANA node, there are two dedicated Fibre Channel ports on Hitachi Virtual Storage Platform G1000. The
Fibre Channel SAN architecture of a SAP HANA node consists of two Fibre Channel cables. Each Fibre Channel cable
connects the 16 Gb/sec Hitachi FIVE-FX Fibre Channel PCI-Ex cards on the chassis with the designated Virtual Storage
Platform G1000 ports.
Table 6 shows the storage port mapping, which is identical for both sites.
Table 4. Hitachi Compute Blade 2500 Chassis Configuration of SAP HANA Nodes for Each Site
Chassis Server Blades SAP HANA NodeName
Role of SAP HANANode
Chassis 1 1, 3, 5, and 7 SAP HANA Node 1 Master
Chassis 1 9, 11, 13, and 15 SAP HANA Node 2 Worker
Chassis 2 1, 3, 5, and 7 SAP HANA Node 3 Standby
Table 5. Server Blade Configuration at Each SiteServer Blades Total 12 server blades
3 nodes with 4 SMP-connected server blades per node
Total Number of CPU Cores 432
Total Memory 9 TB
Table 6. Storage Port Mapping
SAP HANANode
Chassis PCI-Ex slot, Port Virtual StoragePlatform G1000Ports
Node1 Chassis 1 IOBD 01A, Port 0 1CNode1 Chassis 1 IOBD 04A, Port 0 2C
Node2 Chassis 1 IOBD 09A, Port 0 3C
Node2 Chassis 1 IOBD 12A, Port 0 4C
Node3 Chassis 2 IOBD 01A, Port 0 5C
Node3 Chassis 2 IOBD 04A, Port 0 6C
HNAS HNAS1 Hitachi NAS Platform Server 1, FC Port 1 1A
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
18/48
15
15
Set the port properties for the direct connection between Hitachi Compute Blade 2500 and Hitachi Virtual Storage
Platform G1000, as shown in Table 7.
The Hitachi FIVE-FX 16 Gb/sec HBA can emulate FC-SW virtually. Set the BIOS for the Hitachi FIVE-FX HBA to enable for
Multiple Port ID. Use the Fabric storage port setting of ON to set FC-SW virtual mode.
Storage Architecture
The central storage system for the SAP HANA scale-out cluster is a Hitachi Virtual Storage Platform G1000 storage
platform. Several usage aspects divide the space provided by Virtual Storage Platform G1000, as follows:
Operating system LUN provisioning for SAP HANA nodes
Log device provisioning for SAP HANA database
Data device provisioning for SAP HANA database
Block storage provisioning for Hitachi NAS Platform shared file system to store the SAP HANA binaries and cluster-
wide configuration files.
We follow a design that utilizes a building block approach in multiples of four active nodes. So we use a four active node
building block design to provision storage for this setup
Figure 3 on page 17 shows the RAID group configuration for the Virtual Storage Platform G1000 architecture used in the
SAP HANA appliance with four active nodes and one standby node.
Each SAP HANA node has its own data volume and log volume. Only active SAP HANA nodes need data volumes and logvolumes. Standby nodes do not require these volumes.
HNAS HNAS1 Hitachi NAS Platform Server 1, FC Port 3 2A
HNAS HNAS2 Hitachi NAS Platform Server 2, FC Port 1 1B
HNAS HNAS2 Hitachi NAS Platform Server 2, FC Port 3 2B
Table 7. Port Properties
Property Value
Port Attribute Target
Port Security Disabled
Port Speed AutoFabric ON
Connection Type P-to-P
Table 6. Storage Port Mapping (Continued)
SAP HANANode
Chassis PCI-Ex slot, Port Virtual StoragePlatform G1000Ports
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
19/48
16
16
This design follows a four-node building block approach for the SAP HANA data volumes, log volumes, and shared
binaries. Provision the parity groups in Figure 3, as follows.
Operating System Boot LUN
Each node has its own 100 GB LUN on Virtual Storage Platform G1000 for the operating system volumes.
A single parity group configured as RAID-6 (6D+2P) on 900 GB drives provisions the operating system LUN forSAP HANA nodes 1 to 5 (up to a maximum of 19) on Virtual Storage Platform G1000.
From this parity group, create five LDEVs, each with a capacity of 100 GB.
Map each LDEV exclusively to the corresponding SAP HANA node as follows: LUN ID 00.
The installation of SUSE Linux Enterprise Server for SAP Applications or Red Hat Enterprise Linux resides on the
operating system LUN.
Hitachi NAS Platform 4060 Block Storage
The block storage for Hitachi NAS Platform consists of three parity groups on Virtual Storage Platform G1000,
each configured as RAID-6 (6D+2P) on 24 × 900 GB drives to store the shared binaries and configuration files ofthe SAP HANA database.
In each of the three parity groups, create two LDEVs of 2400 GB each.
Create a dynamic provisioning pool named HNAS_HDP_pool. Assign all the created Hitachi NAS Platform LDEVs
to this pool. This allows the use of all the disks concurrently on NAS Platform for better performance.
For a 4-node building block, create six virtual volumes, each with 2400 GB in HNAS_HDP_pool. Do the LUN path
assignment for these virtual volumes to the ports in Table 6 on page 14 connected to Hitachi NAS Platform.
SAP HANA Log Volumes
For the SAP HANA log volumes, create two parity groups configured as RAID-6 (6D+2P) on 16 × 900 GB drives.
In each of the parity groups, create two LDEVs of 600 GB each.
Map each SAP HANA log volume to all SAP HANA nodes at each port with the LUN ID 1 of the specified host.
SAP HANA Data Volumes
For the SAP HANA data volumes, create four parity groups, each configured as RAID-6 (14D+2P) on 64 × 900 GB
drives.
Create four LDEVs with a capacity of 2816 GB per each parity group. Table 8 on page 18 shows the parity groups
and LDEVs created for data volumes.
Assign four LDEVs (with LUN ID 2-5) for use as data volumes to each SAP HANA node, as shown in Table 8.
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
20/48
17
17
Figure 3
Table 8 on page 18 shows the parity groups and LDEV assignment of boot volumes, the Hitachi NAS Platform volumes,
the SAP HANA log volumes, and the SAP HANA data volumes for production system at both the sites.
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
21/48
18
18
Table 9 on page 19 shows the dynamic provisioning pool IDs and virtual volume LDEV IDs for Hitachi NAS Platform.
Table 8. Groups and LDEV Assignment of Operating System Boot, Hitachi NAS Platform, SAP HANA Log Volumes,and SAP HANA Data Volumes for Production System at Primary and Secondary
ParityGroupID
Parity Group RAID Leveland disks
LDEV ID Name LDEV Size
1 RAID-6 (6D+2P) on 900 GB10k RPM SAS drives
00:01:00 HANA_OS_LUN_N1 100 GB00:02:00 HANA_OS_LUN_N2 100 GB
00:03:00 HANA_OS_LUN_N3 100 GB
00:04:00 HANA_OS_LUN_N4 100 GB
2 RAID-6 (6D+2P) on 900 GB
10k RPM SAS drives
00:00:01 HNAS_VOL_1 2400 GB
00:00:02 HNAS_VOL_2 2400 GB
3 RAID-6 (6D+2P) on 900 GB
10k RPM SAS drives
00:00:03 HNAS_VOL_3 2400 GB
00:00:04 HNAS_VOL_4 2400 GB
4 RAID-6 (6D+2P) on 900 GB
10k RPM SAS drives
00:00:05 HNAS_VOL_5 2400 GB
00:00:06 HNAS_VOL_6 2400 GB
5 RAID-6 (6D+2P) on 900 GB
10k RPM SAS drives
00:01:01 HANA_LOG_N1 600 GB
00:02:01 HANA_LOG_N2 600 GB
6 RAID-6 (6D+2P) on 900 GB
10k RPM SAS drives
00:03:01 HANA_LOG_N3 600 GB
00:04:01 HANA_LOG_N4 600 GB
7 RAID-6 (14D+2P) on 900
GB 10k RPM SAS drives
00:01:02 HANA_DATA_N1_01 2816 GB
00:02:02 HANA_DATA_N2_01 2816 GB
00:03:02 HANA_DATA_N3_01 2816 GB
00:04:02 HANA_DATA_N4_01 2816 GB
8 RAID-6 (14D+2P) on 900
GB 10k RPM SAS drives
00:01:03 HANA_DATA_N1_02 2816 GB
00:02:03 HANA_DATA_N2_02 2816 GB00:03:03 HANA_DATA_N3_02 2816 GB
00:04:03 HANA_DATA_N4_02 2816 GB
9 RAID-6 (14D+2P) on 900
GB 10k RPM SAS drives
00:01:04 HANA_DATA_N1_03 2816 GB
00:02:04 HANA_DATA_N2_03 2816 GB
00:03:04 HANA_DATA_N3_03 2816 GB
00:04:04 HANA_DATA_N4_03 2816 GB
10 RAID-6 (14D+2P) on 900
GB 10k RPM SAS drives
00:01:05 HANA_DATA_N1_04 2816 GB
00:02:05 HANA_DATA_N2_04 2816 GB
00:03:05 HANA_DATA_N3_04 2816 GB
00:04:05 HANA_DATA_N4_04 2816 GB
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
22/48
19
19
While mapping the LUN path assignment for each node, add the LUNs in the following order:
1. Map the OS LUN for the specific SAP HANA node.
2. Map the log volume and data volume of each SAP HANA node.
Table 10 shows an example configuration of the LUN path assignment for node01 on primary site. The LUN assignment
would be the same for all nodes except for the first LUN, which would be the operating system LUN of that specific node.
Table 9. Dynamic Provisioning Pool IDs and Virtual Volume LDEV IDs of Hitachi NAS Platform for ProductionSystem at Both Sites
DynamicProvisioning Pool ID
DynamicProvisioningPool Name
Virtual Volume Names Virtual VolumeLDEV ID forHitachiNASPlatformSharedBinaries
Virtual VolumeSize forHitachiNASPlatformSharedBinaries
MPBAssignment
0 HNAS_HDP_Pool HNAS_HANA_VVOL_1 00:0A:01 2400.00 GB MPB0
HNAS_HANA_VVOL_2 00:0A:02 2400.00 GB MPB4
HNAS_HANA_VVOL_3 00:0A:03 2400.00 GB MPB0
HNAS_HANA_VVOL_4 00:0A:04 2400.00 GB MPB4
HNAS_HANA_VVOL_5 00:0A:05 2400.00 GB MPB0
HNAS_HANA_VVOL_6 00:0A:06 2400.00 GB MPB4
Table 10. LUN Path Assignment at Primary Site
LUN ID LDEV ID LDEV Name
0000 00:01:00 hananode01
0001 00:01:01 LOG_1
0002 00:01:02 DATA_1_01
0003 00:01:03 DATA_1_02
0004 00:01:04 DATA_1_03
0005 00:01:05 DATA_1_04
0006 00:02:01 LOG_2
0007 00:02:02 DATA_2_01
0008 00:02:03 DATA_2_02
0009 00:02:04 DATA_2_03
0010 00:02:05 DATA_2_04
0011 00:03:01 LOG_3
0012 00:03:02 DATA_3_01
0013 00:03:03 DATA_3_02
0014 00:03:04 DATA_3_03
0015 00:03:05 DATA_3_04
0016 00:04:01 LOG_4
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
23/48
20
20
Figure 4 shows the LUN and port assignment for the maximum SAP HANA server nodes 19 on each Hitachi Virtual
Storage Platform G1000.
Figure 4
0017 00:04:02 DATA_4_01
0018 00:04:03 DATA_4_02
0019 00:04:04 DATA_4_03
0020 00:04:05 DATA_4_04
Table 10. LUN Path Assignment at Primary Site (Continued)
LUN ID LDEV ID LDEV Name
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
24/48
21
21
Table 11 shows the parity groups and LDEV assignment the Hitachi NAS Platform volumes, the SAP HANA log volumes,
and the SAP HANA data volumes for quality assurance system at the secondary site.
Table 11. Groups and LDEV Assignment of Operating System Boot, Hitachi NAS Platform, SAP HANA Log Volumes,and SAP HANA Data Volumes for Quality Assurance System at the Secondary Site
ParityGroupID
Parity Group RAID Leveland disks LDEV ID LDEV Name LDEV Size
11 RAID-6 (6D+2P) on 900 GB
10k RPM SAS drives
00:00:25 HNAS_VOL_QA_1 2400 GB
00:00:26 HNAS_VOL_QA_2 2400 GB
12 RAID-6 (6D+2P) on 900 GB
10k RPM SAS drives
00:00:27 HNAS_VOL_QA_3 2400 GB
00:00:28 HNAS_VOL_QA_4 2400 GB
13 RAID-6 (6D+2P) on 900 GB
10k RPM SAS drives
00:00:29 HNAS_VOL_QA_5 2400 GB
00:00:30 HNAS_VOL_QA_6 2400 GB
14 RAID-6 (6D+2P) on 900 GB
10k RPM SAS drives
00:01:06 HANA_LOG_QA_N1 600 GB
00:02:06 HANA_LOG_QA_N2 600 GB
15 RAID-6 (6D+2P) on 900 GB
10k RPM SAS drives
00:03:06 HANA_LOG_QA_N3 600 GB
00:04:06 HANA_LOG_QA_N4 600 GB
16 RAID-6 (14D+2P)RAID-6
(14D+2P) on 900 GB 10k
RPM SAS drives
00:01:07 HANA_DATA_QA_N1_01 2816 GB
00:02:07 HANA_DATA_QA_N2_01 2816 GB
00:03:07 HANA_DATA_QA_N3_01 2816 GB
00:04:07 HANA_DATA_QA_N4_01 2816 GB
17 RAID-6 (14D+2P) on 900
GB 10k RPM SAS drives
00:01:08 HANA_DATA_QA_N1_02 2816 GB
00:02:08 HANA_DATA_QA_N2_02 2816 GB
00:03:08 HANA_DATA_QA_N3_02 2816 GB
00:04:08 HANA_DATA_QA_N4_02 2816 GB18 RAID-6 (14D+2P) on 900
GB 10k RPM SAS drives
00:01:09 HANA_DATA_QA_N1_03 2816 GB
00:02:09 HANA_DATA_QA_N2_03 2816 GB
00:03:09 HANA_DATA_QA_N3_03 2816 GB
00:04:09 HANA_DATA_QA_N4_03 2816 GB
19 RAID-6 (14D+2P) on 900
GB 10k RPM SAS drives
00:01:10 HANA_DATA_QA_N1_04 2816 GB
00:02:10 HANA_DATA_QA_N2_04 2816 GB
00:03:10 HANA_DATA_QA_N3_04 2816 GB
00:04:10 HANA_DATA_QA_N4_04 2816 GB
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
25/48
22
22
Table 12 shows the dynamic provisioning pool IDs and virtual volume LDEV IDs for Hitachi NAS Platform.
Table 13 shows an example configuration of the LUN path assignment for Node001 on the primary site. The LUNassignment would be the same for all nodes except for the first LUN, which would be the operating system boot LUN of
that specific node.
Table 12. Dynamic Provisioning Pool IDs and Virtual Volume LDEV IDs of Hitachi NAS Platform for Quality
Assurance System at the Secondary Site
DynamicProvisioningPool ID
DynamicProvisioningPool Name
Virtual Volume Names Virtual VolumeLDEV ID forNAS PlatformSharedBinaries
Virtual Volume Sizefor NASPlatformSharedBinaries
MPBAssignment
1 HNAS_QA_HDP_P
ool
HNAS_QA_VVOL_1 00:0A:25 2400.00 GB MPB0
HNAS_QA_VVOL_2 00:0A:26 2400.00 GB MPB4
HNAS_QA_VVOL_3 00:0A:27 2400.00 GB MPB0
HNAS_QA_VVOL_4 00:0A:28 2400.00 GB MPB4
HNAS_QA_VVOL_5 00:0A:29 2400.00 GB MPB0
HNAS_QA_VVOL_6 00:0A:30 2400.00 GB MPB4
Table 13. LUN Path Assignment at the Secondary Site
LUN ID LDEV ID LDEV Name
0000 00:01:00 hananode01
0001 00:01:01 LOG_1
0002 00:01:02 DATA_1_01
0003 00:01:03 DATA_1_02
0004 00:01:04 DATA_1_03
0005 00:01:05 DATA_1_04
0006 00:02:01 LOG_2
0007 00:02:02 DATA_2_01
0008 00:02:03 DATA_2_02
0009 00:02:04 DATA_2_03
0010 00:02:05 DATA_2_04
0011 00:03:01 LOG_3
0012 00:03:02 DATA_3_01
0013 00:03:03 DATA_3_02
0014 00:03:04 DATA_3_03
0015 00:03:05 DATA_3_04
0016 00:04:01 LOG_4
0017 00:04:02 DATA_4_01
0018 00:04:03 DATA_4_02
0019 00:04:04 DATA_4_03
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
26/48
23
23
Hitachi NAS Platform 4060 Architecture
This describes the architecture for Hitachi NAS Platform 4060 and related systems.
This reference architecture uses two Hitachi NAS Platform 4060 file system modules. They are part of Hitachi Virtual
Storage Platform G1000 in the cluster configuration. The two NAS Platform servers are cluster interconnected with two 10
Gb/sec network links.
Each NAS Platform server directly connects to the Virtual Storage Platform G1000 target ports using two Fibre Channel
cables, from each NAS Platform 4060 node.
System Management Unit
Web Manager, the graphical user interface of the system management unit, provides front-end server administration and
monitoring tools. It supports clustering and acts as a quorum device in a cluster. This solution uses an external systemmanagement unit that manages two NAS Platform servers.
Use one of the following browsers to run Web Manager:
Microsoft Internet Explorer®, version 9.0, or later
Mozilla Firefox, version 6.0, or later
0020 00:04:05 DATA_4_04
0021 00:01:01 LOG_QA_1
0022 00:01:02 DATA_QA_1_01
0023 00:01:03 DATA_QA_1_02
0024 00:01:04 DATA_QA_1_03
0025 00:01:05 DATA_QA_1_04
0026 00:02:01 LOG_QA_2
0027 00:02:02 DATA_QA_2_01
0028 00:02:03 DATA_QA_2_02
0029 00:02:04 DATA_QA_2_03
0030 00:02:05 DATA_QA_2_04
0031 00:03:01 LOG_QA_3
0032 00:03:02 DATA_QA_3_010033 00:03:03 DATA_QA_3_02
0034 00:03:04 DATA_QA_3_03
0035 00:03:05 DATA_QA_3_04
0036 00:04:01 LOG_QA_4
0037 00:04:02 DATA_QA_4_01
0038 00:04:03 DATA_QA_4_02
0039 00:04:04 DATA_QA_4_03
0040 00:04:05 DATA_QA_4_04
Table 13. LUN Path Assignment at the Secondary Site (Continued)
LUN ID LDEV ID LDEV Name
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
27/48
24
24
Private Management Network
Connect the private management interfaces of the Hitachi NAS Platform 4060 servers and the system management unit
to the Brocade ICX 6430-24 port switch. Devices connected to this private ICX 6430-24 port switch are only accessible
through the system management unit.
Public Data Network
The public data network consists of the public Ethernet port of Hitachi NAS Platform 4060 and system management unitsoftware connected to the Brocade ICX 6430-48 switch.
Storage Subsystem
This solution uses Hitachi Virtual Storage Platform G1000 as the storage subsystem. Hitachi NAS Platform has direct
attached Fibre Channel connections with Virtual Storage Platform G1000.
Server Connections
Figure 5 shows the back of Hitachi NAS Platform 4060.
Figure 5
Port C1 and Port C2 are the NAS Platform 4060 cluster ports. To enable clustering, do the following:
Connect Port C1 of first NAS Platform server to Port C1 of the second NAS Platform server.
Connect Port C2 of first NAS Platform server to Port C2 of the second NAS Platform server.
Port tg1 and Port tg2 are 10 GbE ports. Link aggregate and connect these ports to the Brocade VDX 6740-48 switches.
Connect Fibre Channel Port FC1 and Port FC3 directly to the Hitachi Virtual Storage Platform G1000 ports, as follows:
1A and 2A for the first NAS Platform server
1B and 2B for the second NAS Platform server
Connect port eth0 of the NAS Platform server to the management network on the Brocade ICX 6430-48 port switch.
Connect port eth1 of the NAS platform server to the private network on the Brocade ICX 6430-24 port switch.
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
28/48
25
25
For the direct connection between Hitachi NAS Platform and Hitachi Virtual Storage Platform G1000, set the port
properties as shown in Table 14.
Network File System Design for Shared Binaries
This solution requires a network file system to store cluster-wide SAP HANA binaries and configuration files of the in-
memory database. Host this shared file system, called /hana/shared/, on Hitachi NAS Platform 4060. Mount this
file system on all SAP HANA nodes. is the system ID for the SAP HANA production database instance.
Table 8 on page 18 and Table 9 on page 19 show the parity group setup and the twenty four LDEVs and virtual volumesused for NAS Platform in this configuration.
This solution uses six virtual volume LDEVs, as listed in Table 9 on page 19.
Refer to each LDEV as a system drive.
With these system drives, create a single storage pool called HANABIN_.
Configure two EVS on the NAS Platform nodes, as follows:
EVS on NAS Platform node 1 as HNASEVS1
EVS on NAS Platform node 2 as HNASEVS2
Create the shared file system hana_shared_ using the storage pool HANABIN_ with the following:
Capacity based on the number of SAP HANA nodes:
For up to 4 active HANA nodes: 13 TB
For up to 8 active HANA nodes: 26 TB
For up to 12 active HANA nodes: 39 TB
For up to 16 active HANA nodes: 52 TB
Block size of 32 KB
Auto expansion disabled
Mount and then export the file system. Mount the NFS export /hana_shared_ on the file system path /hana/
shared/ on all nineteen SAP HANA nodes.
Set the MTU size to 9000 on both NAS Platform nodes.
Follow similar procedure for the QA system on the secondary site.
Table 14. Hitachi Virtual Storage Platform G1000 Port Properties
Property Value
Port Attribute TargetPort Security Disable
Port Speed Auto (8 Gb/sec)
Fabric OFF
Connection Type FC-AL
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
29/48
26
26
Management Server
This solution uses one node of a four-node Quanta Cloud Technology QuantaPlex T41S-2U server for the management
server. The management server acts as a central device for managing the SAP HANA platform.
Manage the following from the management server:
Hitachi Compute Blade 2500 chassis
520X B2 server blades
Brocade ICX 6430 — 48 port switch
Brocade VDX 6740 switches
System management unit
SAP HANA nodes
Hitachi NAS Platform 4060 servers
Hitachi Virtual Storage Platform G1000
NTP configuration
Hi-Track Remote Monitoring system from Hitachi Data Systems
Hitachi Command Suite and management of the server blades
SAP HANA Studio
Figure 6 on page 27 shows the management server network ports using one dual port 1 GbE Base-T Intel i350 mezzanine
card.
Slot 01 Port 2 — Connect this port to the local area network. It provides 1 GbE network to the management server.
Slot 01 Port 1 — Connect this port to the Brocade ICX 6430-48 port switch that provides 1 GbE network to all other
switches, chassis, and Hitachi NAS Platform nodes.
The management server has the following additional components:
One dual port 10 GbE Intel 82599ES SFP+ OCP mezzanine card
One Emulex 2-port 8 Gb/sec Fibre Channel HBA on the PCIe slot
Connect the 10 GbE network ports to two different Brocade switches, VDX 6740-A and VDX 6740-B, to provide
management access to the SAP HANA nodes from the Quanta 2U4N server using the NFS network.
http://www.quantaqct.com/catalog/microsite/Product/Servers/Rackmount-Servers/Multi-node-Servers/QuantaPlex-T41S-2U-4-Node-p282c77c70c83c185http://www.quantaqct.com/catalog/microsite/Product/Servers/Rackmount-Servers/Multi-node-Servers/QuantaPlex-T41S-2U-4-Node-p282c77c70c83c185
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
30/48
27
27
Figure 6
Install the following software on the management server:
Hitachi Command Suite
Hitachi Compute Systems Manager
Command control interface
Hitachi Dynamic Link Manager
NTP server service
PuTTY
Teraterm
JRE version jre-7u51-windows-i586 (no 64 bit)
Adobe Flash Player
WinSCP
SAP HANA Studio
Network Architecture
For the client network, two Brocade VDX 6740 switches provide external connectivity. In the solution rack, the switch
placement is as follows:
The switch at rack unit 40 is the VDX 6740-D switch 54
The switch at rack unit 39 is the VDX 6740-C switch 53
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
31/48
28
28
The scale-out solution for SAP HANA internally uses the NFS network and the inter-cluster network only. They can share a
switch-pair, given that traffic can be strictly separated. Accomplish this by using VLANs on two ISL-paired Brocade VDX
6740 switches. In the solution rack, refer to the switches as follows:
The switch at rack unit 37 is the VDX 6740-B switch 52
The switch at rack unit 36 is the VDX 6740-A switch 51
The scale-out SAP HANA solution requires five separate networks.
SAP HANA Inter-Cluster Network
This network provides communication between the SAP HANA instances on the cluster.
Connect the SAP HANA inter-cluster network to Switch 51 and Switch 52 (Brocade VDX 6740). Set an MTU size
of 9100, in accordance with Brocade best practices.
Isolate using a VLAN of 100.
Each of these ports utilize active-active bonding mode:
Switch 51 and Switch 52 (VDX 6740 switches)
Port eth9901 and Port eth9902 of the Linux operating system.
SAP HANA Client Network
This network is dedicated to traffic between the SAP HANA database and its clients.
Connect the SAP HANA client network to Switch 53 and Switch 54 (Brocade VDX 6740). Set with an MTU size of
9100, in accordance with Brocade best practices.
By default, isolate using a VLAN of 200. However, a different VLAN can be used to isolate this network.
Each of these ports utilize active-active bonding mode:
Switch 53 and Switch 54 (Brocade VDX 6740 switches)
Port eth9921 and Port eth9922 of the Linux operating system.
Connect the up-link ports of the Brocade VDX 6740-48 switches to the local area network.
SAP HANA NFS Network
This network provides access to SAP HANA shared binaries and configuration files using the NFS protocol.
Connect the SAP HANA NFS network to Switch 51 and Switch 52 (Brocade VDX 6740). Set with an MTU size of
9100, in accordance with Brocade best practices.
Isolate using a VLAN of 150.
Each of these ports utilize active-active bonding mode:
Port eth9911 and Port eth9912 of the Linux operating system
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
32/48
29
29
Hitachi NAS Platform Private Network
This network is used for the NAS Platform heartbeat.
A 1 GbE Brocade ICX6430-24 port switch supplies the heartbeat.
Management Network
This network is used with the management server. See “Management Server,” starting on page 26.
This resides on a 1 GbE Brocade ICX 6430-48 port switch.
The management network does not need to have a VLAN assigned to it.
The Brocade ICX 6430-48 port switch uses the default switch configuration.
The SAP HANA inter-cluster network, client network, and NFS network are required to have the following:
No single point of failure
Provide at least 10 GbE equivalent throughput
To meet these requirements, use four dual-port 10 GbE PCIe cards per SAP HANA node. Bond two ports from different
PCIe network adapters at the operating system level using link aggregation, following the IEEE 802.3ad Link Aggregation
standard for each of the three networks:
SAP HANA inter-cluster
NFS
Client network
Connections of each bond need to go to physically different VDX 6740 switches, so when one switch fails there is still
another route to the corresponding host. This solution connects two switches together using inter switch link. It lets both
switches act together as one single logical switch with the characteristics that, if one switch fails, there still is a path to the
hosts.
The complete network setup uses the ports on the 10 GbE PCI-Ex cards listed in Table 15 as an example configuration for
chassis 1. Follow the similar configuration for SAP HANA nodes on other chassis as well.
Table 15. Network Setup Using 10 GbE PCI-Ex NIC Cards
PCI-Ex Slot Number Port Operating SystemLevel eth Port
Network Description
IOBD 01B 0 eth9921 Client Network for Node01
IOBD 01B 1 eth9911 NFS Network of Node01
IOBD 02A 0 eth9902 Inter-cluster Network for Node01
IOBD 03A 0 eth9901 Inter-cluster Network for Node01
IOBD 04B 0 eth9922 Client Network for Node01
IOBD 04B 1 eth9912 NFS Network for Node01
IOBD 09B 0 eth9921 Client Network for Node02
IOBD 09B 1 eth9911 NFS Network of Node02
IOBD 10A 0 eth9902 Inter-cluster Network for Node02
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
33/48
30
30
SAP HANA Inter-cluster Network Connection for Node 1
Figure 7 shows the SAP HANA inter-cluster network connection for Node 1.
Figure 7
IOBD 11A 0 eth9901 Inter-cluster Network for Node02
IOBD 12B 0 eth9922 Client Network for Node02
IOBD 12B 1 eth9912 NFS Network for Node02
Table 15. Network Setup Using 10 GbE PCI-Ex NIC Cards (Continued)
PCI-Ex Slot Number Port Operating SystemLevel eth Port
Network Description
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
34/48
31
31
Configure the SAP HANA inter-cluster network using operating system-level bonding on every node. Make the following
10 GbE connections, as listed in Table 16.
SAP HANA NFS Network Connection for Node 1
Figure 8 shows the SAP HANA NFS network connection for Node 1.
Figure 8
Table 16. SAP HANA Inter-Cluster Port Mapping
Chassis, PCI-Ex Slot Number, Port VDX 6740 Switch and Port Bond
Chassis 1, IOBD 03A, Port 0 VDX 6740-A, Port #1 Bond 0 of Node 1Chassis 1, IOBD 02A, Port 0 VDX 6740-B, Port #1 Bond 0 of Node 1
Chassis 1, IOBD 11A, Port 0 VDX 6740-A, Port #2 Bond 0 of Node 2
Chassis 1, IOBD 10A, Port 0 VDX 6740-B, Port #2 Bond 0 of Node 2
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
35/48
32
32
Configure the SAP HANA NFS network using operating system-level bonding on every node. Make the 10 GbE
connections using the mappings in Table 17.
SAP HANA Client Network Connection
Figure 9 shows the SAP HANA client network connection.
Figure 9
Table 17. SAP HANA NFS Network Port Mappings
Chassis, PCI-Ex Slot Number, Port VDX 6740 Switch and Port Bond
Chassis 1, IOBD 01B, Port 1 VDX 6740-A, Port #21 Bond 1 of Node 1Chassis 1, IOBD 04B, Port 1 VDX 6740-B, Port #21 Bond 1 of Node 1
Chassis 1, IOBD 09B, Port 1 VDX 6740-A, Port #22 Bond 1 of Node 2
Chassis 1, IOBD 12B, Port 1 VDX 6740-B, Port #22 Bond 1 of Node 2
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
36/48
33
33
Configure the SAP HANA client network using operating system-level bonding on every node. Make the following 10 GbE
connections using the port mappings shown in Table 18.
SAP Storage Connector API Fibre Channel Client
The SAP HANA storage connector API Fibre Channel client defines a set of interface functions called during the following
Normal SAP HANA cluster operation
Failover handling
Storage connector clients implement the functions defined in the storage connector API.
The scale-out of Hitachi Unified Compute Platform for the SAP HANA platform uses the fcClientLVM implementation,
which supports the use of logical volume manager. SAP supports this solution to enable the use of high-performance
Fibre Channel devices for a scale-out installation.
The fcClientLVM implementation uses standard Linux commands, such as multipath and sg_persist. Install and configure
these commands.
The fcClientLVM implementation is responsible for mounting the SAP HANA volumes. It also implements a proper fencing
mechanism during a failover by means of SCSI-3 persistent reservations.
Configuration of the SAP Storage Connector API is contained within the SAP global.ini file in /hana/shared//
global/hdb/custom/config.
Journal Sizing
The following are maximum throughput numbers, per journal:
If the distance between the sites is less than 2000 km (about 1200 miles), then the maximum throughput is about 750
MB/sec.
If the distance is greater than 2000 km, then the maximum throughput is about 500 MB/sec.
If the distance is greater than 5000 km (about 3100 miles), then the maximum throughput is about 350 MB/sec.
With one RAID group configured as RAID-6 (6D+2P) using 900 GB SAS drives, testing in the Hitachi Data System lab
achieved a throughput of 69 MB/sec.
For the base configuration of the solution, it is recommended to use at least two RAID groups configured as RAID-6
(6D+2P) with 900 GB SAS drives in a dynamic provisioning pool for use as a journal group.
Use this is the formula used to calculate the journal capacity :
Journal Capacity = Peak hour megabytes change × Number of hours
Table 18. SAP HANA Client Network Port Mappings
Chassis, PCI-Ex Slot Number, Port VDX 6740 Switch and Port Bond
Chassis 1, IOBD 01B, Port 0 VDX 6740-C, Port #1 Bond 2 of Node 1Chassis 1, IOBD 04B, Port 0 VDX 6740-D, Port #1 Bond 2 of Node 1
Chassis 1, IOBD 09B, Port 0 VDX 6740-C, Port #2 Bond 2 of Node 2
Chassis 1, IOBD 12B, Port 0 VDX 6740-D, Port #2 Bond 2 of Node 2
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
37/48
34
34
Table 19 provides the journal sizing information.
Using the two RAID groups configured as RAID-6 (6D+2P), create LDEVs as in Table 20.
Create a dynamic provisioning pool named HUR_Journal_Group and assign all the LDEVs created in Table 20 to this pool.
Create the four virtual volumes in Table 21, each with 2400 GB for use as a journal volume.
To achieve a zero RPO, for a distance lower than 2000 km (about 1240 miles) we need the maximum of 750 MB/sec
journal throughput which is only possible by the use of 11 RAID-6 (6D+2P) parity groups.
Table 19. Journal Sizing
Number of RAIDgroups configured asRAID-6 (6D+2P)
Hitachi UniversalReplicator PeakWrite
Throughput inMB/sec
HitachiUniversalReplicator Peak
WriteThroughput inGB/hour
Hitachi UniversalReplicatorJournal Space in
GB
Hours for journalspace: (Journalspace in GB)/
(peak GB/hour)
2 138 485 9600 19.7
3 207 727 14400 19.8
4 276 970 19200 19.7
5 345 1212 24000 19.8
6 414 1455 28800 19.7
7 483 1698 33600 19.7
8 552 1940 38400 19.7
9 621 2183 43200 19.710 690 2425 48000 19.7
11 759 2668 52800 19.7
Table 20. LDEVs for Use with HUR_Journal_Group Dynamic Provisioning Pool
ParityGroupID
Parity Group RAIDLevel and disks
LDEV ID LDEV Name LDEV Size MPBAssignment
1 RAID-6 (6D+2P) on
900 GB 10k RPMSAS drives
00:0B:01 Journal_1 2400 GB MPB0
00:0B:02 Journal_2 2400 GB MPB4
2 RAID-6 (6D+2P) on
900 GB 10k RPM
SAS drives
00:0B:03 Journal_3 2400 GB MPB0
00:0B:04 Journal_4 2400 GB MPB4
Table 21. Dynamic Provisioning Pool IDs and Virtual Volume LDEV IDs
DynamicProvisioning
Pool ID
Dynamic ProvisioningPool Name
Virtual VolumeNames
Virtual Volume
LDEV ID
Virtual Volume
size
MPBAssignment
1 HUR_Journal_Group_1 Journal_VVOL_1 00:0C:01 2400.00 GB MPB0
Journal_VVOL_2 00:0C:02 2400.00 GB MPB4
2 HUR_Journal_Group_2 Journal_VVOL_3 00:0C:03 2400.00 GB MPB0
Journal_VVOL_4 00:0C:04 2400.00 GB MPB4
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
38/48
35
35
During implementation of the Hitachi Universal Replicator service, from Hitachi Data Systems Global Services needs to
right-size the journal volumes based on the actual workload, throughput, and RPO requirement. Then, the following needs
to happen:
Add additional disks to create a journal volume of RAID groups configured as RAID-6 (6D+2P) on 900 GB drives.
Create additional LDEVs and add them to the existing dynamic provisioning pool HUR_Journal_Group.
For every single RAID group added to the pool, create two virtual volumes of 2400 GB size to use as a journal volume
Use this is the formula used to calculate the journal capacity :
Journal Capacity = Peak hour megabytes change × Number of hours
Inter-site Configuration
SAN switch and long distance amplifiers must be between the primary site and the secondary site, as and when
applicable.
If you have the SAN switches and long distance amplifiers in the existing infrastructure, you can utilize the same
infrastructure.
Table 22 lists the target and initiator ports of the two storage systems at each site along with zoning alias. Both sites need
one zoning configuration.
Table 23 has the details on the zoning between the management server and Hitachi Virtual Storage Platform G1000.
Create a single zone named MGMT_Pri_Sec.
Add all four Virtual Storage Platform G1000 ports aliases and all of the four management server Emulex port aliases in
the MGMT_Pri_Sec zone.
With this configuration, command devices on the primary system and secondary system are accessible on the
management servers at the primary site and secondary site.
Table 22. Zoning Configuration
Initiator Port RCU Target Port Zone Name
PrimA_Port3B SecB_Port7B PrimA_Port3B_SecB_Port7B
PrimA_Port4B SecB_Port8B PrimA_Port4B_SecB_Port8B
SecB_Port3B PrimA_Port7B SecB_Port3B_PrimA_Port7B
SecB_Port4B PrimA_Port8B SecB_Port4B_PrimA_Port8B
Table 23. Hitachi Compute Rack Management Server Zoning
Virtual StoragePlatformG1000 Alias
Hitachi ComputeRack ManagementServer Alias
Zone Name
PrimA_Port5B MGMT_PRI_Port0 MGMT_Pri_Sec
SecB_Port5B MGMT_SEC_Port0 MGMT_Pri_Sec
PrimA_Port6B MGMT_PRI_Port1 MGMT_Pri_Sec
SecB_Port6B MGMT_SEC_Port1 MGMT_Pri_Sec
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
39/48
36
36
Disaster Recovery and Replication Components
In this reference architecture for SAP HANA disaster recovery, Hitachi Universal Replicator setup requires doing the
following:
“Install Command Control Interface” on page 36
“Install Hitachi Dynamic Link Manager” on page 36
“Configure Command Devices” on page 36
“Configure Replication using Command Control Interface,” starting on page 36
“Setup Hitachi Universal Replicator,” starting on page 39
Install Command Control Interface
Command control interface enables you to perform storage system operations by issuing commands to Hitachi Virtual
Storage Platform G1000.
In this solution, install command control interface on the management server used as a management server for the
primary site and the secondary site. Command control interface has the following components residing in these locations
Storage System — Command devices and Hitachi Universal Replicator volumes (P-VOLs and S-VOLS)
Quanta Cloud Technology QuantaPlex T41S-2U Management Server — Hitachi Open Remote Copy Manager
Install Hitachi Dynamic Link Manager
Install the Hitachi Dynamic Link Manager software on the management server for the primary site and the secondary site.
Dynamic Link Manager manages the access paths to the storage system.
Dynamic Link Manager provides the ability to distribute loads across multiple paths and switch to another path if there is
a failure in the path currently being used, improving system availability and reliability.
Configure Command Devices A command device is a dedicated logical volume on the storage system that functions as the interface to the storagesystem from the host. The command device accepts commands from the host that are executed on the storage system.
In this solution, create a 100 MB command device logical volume on the local and remote storage system. Each
management server has one dual-port Emulex HBA card, connected through the Brocade 7800 or Brocade 7840 switch
to Hitachi Virtual Storage Platform G1000. Perform zoning and add the LUN path for the command devices in such a way
that the primary site management server and the secondary site management server can access the command devices
on both storage systems.
Configure Replication using Command Control Interface
A key aspect of this reference architecture on Hitachi Virtual Storage Platform G1000 is defining the volume pair
relationship for replication between storage systems. Define and manage storage replication relationships through the
Hitachi Storage Navigator graphical user interface or on the management server running Hitachi Open Remote CopyManager.
The Hitachi Open Remote Copy Manager operates as a daemon process on the host. When activated, Hitachi Open
Remote Copy Manager refers to its configuration files. The Hitachi Open Remote Copy Manager instance communicates
with the storage sub-system and remote servers.
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
40/48
37
37
Two instances of Open Remote Copy Manager are required for Hitachi Universal Replicator replication to be operational.
A Hitachi Open Remote Copy Manager instance on the primary management server manages the P-VOLs.
A Hitachi Open Remote Copy Manager instance on the secondary management server manages the S-VOLs.
The Hitachi Open Remote Copy Manager configuration file defines the communication path and the logical units to be
controlled. Each instance has its own configuration file. The configuration file lists the following for replication:
SAP HANA data volumes
Log volumes
Hitachi NAS Platform LUNs
Figure 10 shows the content of the configuration file (horcm04.conf) used by the Hitachi Open Remote Copy Manager
instance on the primary management server.
Figure 10
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
41/48
38
38
Figure 11 shows the configuration file (horcm06.conf) files used by the Hitachi Open Remote Copy Manager instance on
the secondary management server.
Figure 11
Figure 12 lists the entries that need for adding to the services file of the management server on both sides for Open
Remote Copy Manager to function.
Figure 12
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
42/48
39
39
Setup Hitachi Universal Replicator
The reference architecture setup is as follows:
For the failover to the secondary site, this solution uses two initiator ports on Hitachi Virtual Storage Platform G1000
at the primary site connected to two RCU target ports on Hitachi Virtual Storage Platform G1000 at the secondary
site.
For the failback to the primary site, it uses two initiator ports from the storage system at the secondary site connected
to the two RCU target ports on the storage system at the primary site.
The initiator and RCU target ports on Hitachi Virtual Storage Platform G1000 on the primary site connect to the
Brocade 7800 Fibre Channel switch at the primary site.
The initiator and RCU target ports on Hitachi Virtual Storage Platform G1000 on the secondary site connect to the
Brocade 7800 Fibre channel switch at the secondary site.
Define the port attributes for initiator and target ports on Hitachi Virtual Storage Platform G1000. Configure the
storage system for Hitachi Universal Replicator replication by defining the logical paths for replication. Refer to the
Hitachi Virtual Storage Platform G1000 Hitachi Universal Replicator User Guide for the setup of logical paths for
replication and defining port attributes.Configure Hitachi Universal ReplicatorConfiguring Hitachi Universal Replicator for Hitachi Unified Compute Platform for the SAP HANA platform requires the
following steps. The detailed implementation steps are in Hitachi Virtual Storage Platform G1000 - Hitachi Universal
Replicator User Guide. Contact your Hitachi Data Systems representative if you need this document.
1. Define the Fibre Channel port attributes.
Define the port attributes for initiator and target port on Virtual Storage Platform G1000.
2. Setup the logical path between the primary system and the secondary system.
Associate the primary system and the secondary system in the Universal Replicator relationships and define the
logical paths between them. This is required in order to perform the Universal Replicator pair operations.
3. Create parity groups and LDEVs for journal groups.
Create journal group RAID groups and LDEVs for use as journal volumes, as described in Journal Sizing.
4. Register journal volumes in a journal.
Register every journal volume in the journal group.
Start the Hitachi Open Remote Copy Manager Instance
To start up the Hitachi Open Remote Copy Manager instance on the primary management server, issue the following
command:
C:\horcm\etc\horcmstart 04
To start up the Open Remote Copy Manager instance on the secondary management server, issue the following
command:
# C:\horcm\etc\horcmstart 06
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
43/48
40
40
Initial Pair Copy Opearation
Perform the initial data transfer, called the pair copy operation, between the primary site and the secondary SAP HANA
node volumes in data/log/HNNAS with the following command, issued on the primary side:
# C:\horcm\etc\paircreate -IH04 –g HANADR -vl –f async 0
When executing the paircreate command, the initial copy happens. The primary storage system copies all the data in
sequence from the P-VOL directly to the S-VOL.
During the initial copy process, the status of the P-VOL and S-VOL is COPY. On completion of the initial copy process, the
status of the P-VOL and S-VOL changes to PAIR.
Initial Configuration for Replication of Hitachi NAS Platform 4060 LUNs
To use Hitachi Universal Replicator to replicate the SAP HANA LUNs on Hitachi NAS Platform, perform the following initial
configuration steps. This is a one-time configuration to setup the RAID mirror relationship between LUNs on Hitachi NAS
Platform. The steps only list a high-level overview of the important RAID mirroring commands on NAS Platform.
To perform the initial configuration, do the following.
1. Complete the initial pair copy (pair create) operation between the primary site and the secondary site for SAP HANA
these volumes:
Data
Log
NAS Platform
2. Perform the initial NAS Platform mirroring.
(1) On any instance of command control interface, validate that the primary site and the secondary site are correctly
paired and synchronized at "PAIR" status.
(2) On the console of NAS Platform for the secondary site, do the following:
i. Verify HANA_SHARED_ shared file system is unmounted.
ii. Copy the cluster information (cluster UUID and the cluster name) in a text editor window and keep it for later.
iii. Log on as root to the SMU of the secondary site.
iv. Verify that you are in the root folder.
v. Run the commands to get the luids and cod information of the NAS Platform disks to be replicated.
vi. Copy these files to the SMU on the primary site.
(3) On the console of NAS Platform for the primary site, do the following:
i. Log on as root to the SMU of the primary site.
ii. Go to the folder where you copied the files from the secondary site.
iii. Run the command to mirror the disks.
iv. List the span information to confirm the mirror relationship.
v. Add the UUID of the NAS Platform on the secondary site to the span, using the cluster UUID and cluster
name using information from Step 2.ii .
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
44/48
41
41
(4) Log on to the secondary site:
i. Rescan the cod for the span.
ii. List the span. Expect a clean output, not showing the production instance span.
3. Test the configuration by performing failover to the secondary site.
(1) Ensure the pair is synchronized completely.
(2) Shutdown Production on the Primary site
(3) Unmount /hana/shared/, the data file system, and the log file system at the primary site for production instance on
the SAP HANA nodes as well as Hitachi NAS Platform servers.
(4) Go to the secondary site and do the following:
i. If it exists, shut down the quality assurance instance.
ii. Unmount /hana/shared/, the data file system, and the log file system at the secondary site for quality
assurance instance on the SAP HANA nodes as NAS Platform.
iii. Using command control interface, run a pair split with a read write.
iv. List the file system. This should show HANA_SHARED_ as unmounted.
v. After the first failover, use 'evsfs' to bind each file system to an EVS at the secondary site.
vi. Mount the production shared file system on NAS Platform.
vii. Mount the production shared file system on SAP HANA nodes.
viii.Check at the operating system level of the SAP HANA nodes if the /hana/shared file system is mounted.
ix. Start the SAP HANA system and validate if it successfully comes up.
4. Test the configuration by performing failback to primary site.
(1) Shutdown the production SAP HANA database at the secondary site. Umount the hana_shared_ file system
on the secondary NAS Platform cluster.
(2) Do a pair resync with swaps. Once it is 100% completed, start the failback.
(3) At the primary site, do the following:
i. On command control interface, run the pair split with read and write.
ii. On the SMU, list the spans. This ensures the mirror relationship.
iii. Mount the hana_shared_ file system on the primary NAS Platform cluster and HANA nodes. Check at
the operating system level of SAP HANA nodes if the /hana/shared file system is mounted.
iv. Start the SAP HANA system and validate if it successfully comes up.
v. Once validation completed, run the pair resync with swaps.
If one site is permanently lost and the surviving LUs are promoted into the SSWS state, it is necessary to run 'sd-peg -up'
on the surviving NAS Platform cluster to make it treats the S-VOLs as P-VOLs. Otherwise, 'sd-peg' should never be used
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
45/48
42
42
In addition, registry changes made on one cluster while it is in production always need recording when made, and then
copied to the other cluster after the next failover:
If creating any new file systems have, bind them to EVSs using the 'evsfs' command, and then exported.
If deleting any file systems on one cluster, delete them from the registry of the other cluster by the filesystem-forget-
and-delete-nv-data command.
If any exports have been created, deleted, or modified on one cluster, make the same changes on the other cluster.
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
46/48
43
43
Engineering Validation Validation of this reference architecture was conducted in the Hitachi Data Systems laboratory. The steps to failover to the
secondary site and then to failback to primary site with soft and hard techniques using Hitachi Universal Replicator were
tested.
Test MethodologyTo test the setup, the following scenarios were executed in the lab:
Planned failover to the secondary site
Planned failback to the primary site
Planned failover to the secondary site during mid-flush and then failback to the primary
Unplanned failover to the secondary site
Automated failover and failback using Hitachi Disaster Recovery Manager for SAP HANA without quality assurance on
the secondary site
Test Results
All the tests passed without issues. The RTO was less than an hour.
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
47/48
For More Information
Hitachi Data Systems Global Services offers experienced storage consultants, proven methodologies and a
comprehensive services portfolio to assist you in implementing Hitachi products and solutions in your environment. For
more information, see the Hitachi Data Systems Global Services website.
Live and recorded product demonstrations are available for many Hitachi products. To schedule a live demonstration,
contact a sales representative. To view a recorded demonstration, see the Hitachi Data Systems Corporate Resources website. Click the Product Demos tab for a list of available recorded demonstrations.
Hitachi Data Systems Academy provides best-in-class training on Hitachi products, technology, solutions and
certifications. Hitachi Data Systems Academy delivers on-demand web-based training (WBT), classroom-based
instructor-led training (ILT) and virtual instructor-led training (vILT) courses. For more information, see the Hitachi Data
Systems Services Education website.
For more information about Hitachi products and services, contact your sales representative or channel partner or visit
the Hitachi Data Systems website.
http://www.hds.com/services/http://www.hds.com/corporate/resources/http://www.hds.com/services/education/http://www.hds.com/http://www.hds.com/http://www.hds.com/http://www.hds.com/services/education/http://www.hds.com/corporate/resources/http://www.hds.com/services/http://www.hds.com/services/education/http://www.hds.com/corporate/resources/http://www.hds.com/services/
-
8/19/2019 Disaster Recovery Using Hur on Ucp for Sap Using Cb2500 Vsp g1000 and Nas 4060
48/48
1
Corporate Headquarters
2845 Lafayette Street
Santa Clara, CA 96050-2639 USA
www.HDS.com community.HDS.com
Regional Contact Information
Americas: +1 408 970 1000 or [email protected]
Europe, Middle East and Africa: +44 (0) 1753 618000 or [email protected]
Asia Pacific: +852 3189 7900 or [email protected]
http://www.hds.com/http://localhost/var/www/apps/conversion/tmp/scratch_7/community.HDS.commailto:[email protected]:[email protected]://localhost/var/www/apps/conversion/tmp/scratch_7/+85231897900mailto:[email protected]://www.youtube.com/user/HDScorphttps://www.facebook.com/HitachiDataSystemshttps://www.linkedin.com/company/hitachi-data-systemshttps://twitter.com/HDScorphttp://localhost/var/www/apps/conversion/tmp/scratch_7/+85231897900mailto:[email protected]:[email protected]:[email protected]://localhost/var/www/apps/conversion/tmp/scratch_7/community.HDS.comhttp://www.hds.com/