Disaster Recovery & Risk management - ICC Thermal Mapping

57
CONFIDENTIAL COMMUNICATION This Presentation is for your organization’s review only. It is not to be released outside of your organization without written permission. This presentation contains confidential, proprietary, or legally privileged information. No confidentiality or privilege is waived or lost by any erroneous transmission or distribution. If you receive this presentation in error, please immediately delete it and all copies of it from your system, destroy any hard copies of it and notify the sender, ICC Thermal Mapping and Surveying at [email protected] You must not, directly or indirectly, use, disclose, distribute, print, or copy any part of this presentation or attached copyrighted imagery, if your are the intended recipient. ICC Thermal Mapping & Surveying/Infrared Concepts Corporation reserves the right to monitor all E: mail communications through its network. Support Information including References & Proof of Insurance is available from ICC via E: mail, FAX or Hard Copy Contact Information: Valerie B. Patterson MBE, CEU, President Stan McDougall, CEU, CEO, COO, Patent Owner ICC THERMAL MAPPING & SURVEYING/ Infrared Concepts Corporation 465 S. Orlando Ave, Suite 321 Maitland, Florida 32751-5844 HQ Phone: 407-629-8485 HQ FAX: 407-339-2029 E: Mail: [email protected] Website: www.iccthermalmapping.com Serving Property Owners and Their Agents since 1989

Transcript of Disaster Recovery & Risk management - ICC Thermal Mapping

CONFIDENTIAL COMMUNICATIONThis Presentation is for your organization’s review only.

It is not to be released outside of your organization without written permission.

This presentation contains confidential, proprietary, or legally privileged information. No confidentiality or privilege is waived or lost by any erroneous transmission or distribution. If you receive this

presentation in error, please immediately delete it and all copies of it from your system, destroy any hard copies of it and notify the sender, ICC Thermal Mapping and Surveying at [email protected]

You must not, directly or indirectly, use, disclose, distribute, print, or copy any part of this presentation or attached copyrighted imagery, if your are the intended recipient.

ICC Thermal Mapping & Surveying/Infrared Concepts Corporation reserves the right to monitorall E: mail communications through its network.

Support Information including References & Proof of Insuranceis available from ICC via E: mail, FAX or Hard Copy

Contact Information:Valerie B. Patterson MBE, CEU, President

Stan McDougall, CEU, CEO, COO, Patent Owner

ICC THERMAL MAPPING & SURVEYING/ Infrared Concepts Corporation465 S. Orlando Ave, Suite 321Maitland, Florida 32751-5844

HQ Phone: 407-629-8485HQ FAX: 407-339-2029

E: Mail: [email protected]: www.iccthermalmapping.com

Serving Property Owners and Their Agents since 1989

DISASTER RECOVERYAnd

RISK MANAGEMENTfor BUILDING ENVELOPES

Accurate & VerifiableBUILDING ENVELOPE ASSESSMENTFrom ICC Thermal Mapping & Surveying!

Digital Thermal Mapping

US Patent #5,818,951

ICC’s Thermal Mapping Forensic Assessment

Capabilities:1. Full Delineation of Roof/Wall Envelope

Moisture, Approaches 100% delineation

2. Computer Analysis – Beyond Human Eye capabilities provides precise Shape, Size, & Location of Moisture Penetrations

FULL ENVELOPE STUDIES: Clearly DenoteMoisture Penetrations & Façade Delaminations

Landon State Office Building – State Of Kansas

Thermal Mapping Accuracy Parameters:

• 95%+ Overall Accuracy.* A 1st for the NDT Industry

• Area spread Accuracy down to 2 SF. A 1st

for the NDT Industry

• Linear Accuracy to 1”/1 pixel AIA 1”=50’

* Proven over 10+ years by independent ASTM Roof Coring & Gravimetric Lab Tests

ICC’s Patented Thermal Mapping Yields:

• Full Envelope Moisture/Energy Loss Delineation less Windows & Doors

• 30-45 Day Finished Report Delivery from Data Capture Depending on Mission Size

• Cost Effective/ROI & Legally Admissible

Four Basics Of ICC’s Thermal Mapping:

1) Daytime and Night-time ROOF DATA is Captured viaHelicopters in hover-mode to obtain Portrait Quality,

Still Imagery

2) WALL FACADES – Up to 3 Stories shot from ground level, beyond 3 Stories a lift is utilized

3) All Thermal Data is Computer Mapped & Analyzed: Image Enhanced & Military style, Multi-pass Analysis Performed

4) Certified Level 3/Building Sciences ThermographersReview and Analyze Results

Two Complete Mapping Passes w/Varying levels of Sensitivity Clearly Identify Moisture Intrusion in

Various Low-slope Commercial Roof Systems:

Built-up, EPDM, Mod-bit, TPO, PVC, Single/Multi-ply, etc.

Wall Report Clearly Identifies Moisture Intrusion/Energy Loss Points

in Varying Wall Façade Material Types:

STUCCO, BRICK, TERRA COTTA, CMU Block & EIFS-Dryvit

Majority of Insulation Types Included:

Lightweight Insulating Concrete, ISO Board, Perlite, Fiberglass, Various Foams, Extruded Poly,

etc.

Without regard to Deck Materials

ICC is “Rocket Science” for Roofs and Walls, similar to these IR Computerized Images from

the Hubble Infrared Telescope

ICC provides verifiable intelligence Beyond Human Eye Results

Pixel Level Analysis & Computer Mapping

Similar to current Medical Imaging & Analysis, Thermal Mapping Creates a Supremely Accurate Map

Think of the Process as a Thermal Based MRI/CAT SCAN

HOW AMAZING IS ICC’sPATENTED PROCESS?

• Routinely detects 30/40%+ moisture content BELOW SATURATION POINT (No leaking yet)Another NDT Industry 1st

• Detects virtually all Vertical/Horizontal area spreads Above Saturation Point AND LEAK SOURCES within moisture field

• ICC’s Thermal Mapping has NEVER Tested below 95% Accurate on Red Marked areas over 10 years*

* Testing by Independent 3rd Parties, ASTM Guideline Roof Cores & Gravimetric Tests at a Certified Labs

60 Year Old Infrared Methods compared to

ICC’s Thermal Mapping

Most Insurance Adjusters Still UseThis 60 Year Old Technology: Handheld IR

(Is this an Attempt to Mitigate Claims?)

HANDHELD/WALKOVER INFRARED* 60 Year Old Technology *

Note HAND-HELD CAMERA:

Taken At Night By A Team Including Your StaffEach Image = 200 SF/60 DEGREE ANGLE.

100,000 SF Roof = 500 ImagesThis Obsolete Method is Error Prone, Slow, and Dangerous

OSHA Regulations Are Violated Due to Absence of Tethers & Harnesses

HANDHELD/WALKOVER Data is thenHand Transferred to a ROOF PLAN:

This Analog Process is accompanied by Human Error, Transpositions & Misalignments

“Photoshopping” Thermal Imagery ISN’T Thermal Mapping Of Your Buildings!

1) Retouching ONLY Changes Black/White Ratio (contrast)

2) Photoshop Software DOES NOTExpose Hidden Moisture

3) Data Manipulation, “Photoshopping” creates Erroneous Impression this Imagery is Superior to ICC’s Patented Process

4) Increased Altitude/Forward Motion Degrades IR Imagery Vs. low altitude, hovering Helicopter

5) Hot Exhaust passing by the IR Camera confuses Thermal Imagery

6) Only Reveals LARGE HOT-SPOT’s Following Data Manipulation

Fixed Wing Aerial Infrared30 Year Old Technology:

Forward Motion of the Aircraft Smears the IR Data

Poor Moisture Delineation & its still a Hand Transfer processWith Human Eye Analysis - Note Hand Applied Arrows.

6.8% Wet

Airplane

21.8% Wet

Helicopter

DATA COLLECTION – AIRPLANE VS. HELICOPTER AND ICC’S PATENTED PROCESS

AT OHIO UNIVERSITY THE AIRPLANE MISSED OR MISCALLED 69%WHILE THE ICC PATENTED, COMPUTER ANALYZED REPORT WAS 100% ACCURATE.

3 Times the Anomalies were Identified by ICC.– 2/3 of the problems were missed by the Airplane provider who simply eye-balled hot spots

Thermal Mapping SuperiorityRaw Thermogram Thermal Map

This Roof’s West Side is NOT Eye Readable While its East Side is Eye Readable.

Thermal Mapping Perfectly Reads Both Sides

AIRPLANE AND OTHER IR SERVICES ID ONLY LARGE SPOTS

Would you Pay $100,000 for a Brain Operationthat Leaves Cancer Behind? Or millions for roof repair that leaves

moisture behind? ICC’s clients report our accuracy using the helicopter & the U.S. Patent as exceeding 95% --

Let’s Watch ICC’s Thermal Mapping Patent in ACTION!

ICC CAN REVEAL WHAT CANNOT BE SEENWhen Eye-Reading a Raw Thermogram

Trade Secret Direct Output Scaled Roof Data - NO Building Owner Measurements Required

AIA STANDARD SCALING ON ROOFS:

Between 1” = 20 ft/1” = 50 ft

Military Grade - Raw Infrared Roof Image

INFRARED IMAGE - CAPTURED AT NIGHT

Infrared Image - Colorized Into Layers

DIGITAL TEMPERATURE MAPPING

Computer Removes Normal Temperatures Above Targeted Range

HIGH TEMPERATURES REMOVED

Computer Removes Normal Temperatures Below Targeted Range

LOW TEMPERATURES REMOVED

Infrared Processed - Eliminating Normal Conditions

LOW TEMPERATURE ANOMALIES REMOVED

Image’s Opacity Changed To Determine Thermal Sources

THERMAL PATTERNS ARE RENDERED TRANSPARENT

Processing Then Continues For All Other Roof Sections

Process Continues For All Other Roof Sections

Process Continues For All Other Roof Sections

End Result = Thermal Map Unavailable Via Any Other Method

Resulting in an ACCURATE ReportEVERYONE CAN UNDERSTAND!

ICC Reveals What is NOT Eye-Readableon a Raw Thermogram,

Even to Trained & Certified Thermographers

THE INVISIBLE MADE CLEAR

ICC is Unique Among Forensic Disaster Recovery

Methods Because It Accurately Identifies…

HIDDEN DAMAGE(Not Visible to the Human Eye)

Visible Damage Vs.Hidden Damage

• Everyone covers Visible Damage within 3rd Party Insurance Policy Guidelines.

• FEMA begins coverage where 3rd Party Visible Claims are insufficient.

• BOTH 3rd party Insurance & FEMA will pay for Hidden Damage that can be

PROVEN

Thermal Maps Prove BOTHVisible Damage & Hidden DamageOld-style Handheld IR as sometimes used by 3rd Party Insurance reports

only LARGE HOT SPOTS Above Saturation Point

Hand-held IR routinely misses up to 50% of a Building’s total Moisture.

ICC’s Thermal Maps are VERIFIABLE SCIENCE

Not Opinions or Best Guesses & They’re easily understood

by anyone...

FEMA RESPECTS ICC’s REPORTS!

Why Does FEMA Respect ICC?

• Pre & Post ICC Reports Prove Building Condition in concert with follow up ASTM Coring & Gravimetric Tests

• Pre & Post Reports minimize Pre-Existing Damage Arguments & Claim Denial

• Post Event Only Mapping is still a valuable resource. A Seasoned Consultant is a MUST to Link Damages to the Event

3rd Party Insurance Companies

1) Refuse Hidden Damage Until Proven2) ALWAYS Seek to MINIMIZE Claim

Awards to Building Owners3) Normally Demand Both Thermal

Mapping and Destructive Testing4) Destructive Includes ASTM Coring &

Independent Gravimetric Lab Tests which ICC will Assist in Managing

ICC’s Thermal MappingThe ULTIMATE Claim Justification

Tool in the Hands ofQualified, Experienced,

Disaster Recovery Specialistsworking as the owner’s advocates:ICC Thermal Mapping & Surveying

EVIDENCE:ICC’s Thermal Mapping is

verifiable evidence and is the Future of Claims Resolution

Use ICC’s Evidence to Minimize Arguments on Pre-

Existing Damage, Speed Awards & Deter Lawsuits

DISASTER RECOVERYBEST PRACTICE

1. Annual Thermal Mapping Baseline of all your Campuses & Buildings

2. Post Event Mapping

3. Independent ASTM Guideline Coring & Gravimetric Core Testing at an ASTM Certified Lab which ICC will Assist in Managing

HURRICANE DAMAGE RECOVERY EXAMPLES

Note: Although the following Examples are Hurricane based,

Thermal Mapping works exactly the same for

Tornadoes, Large Hail, Flooding, Excessive Rain/Wind & MicroBursts

FLORIDA HURRICANES:Charlie - September 2004

Jeanne - October 2004

• The Following Orlando International (MCO) Terminal was Dry in the Annual Pre Hurricane Season inspection

• Post Hurricane Charlie Thermal Map

• Post Hurricane Jeanne Thermal Map

Orlando International Airport (MCO) Terminal

After CHARLIE After JEANNE

RED areas are indicative of sub-membrane moisture

Pre Hurricane inspection was “Clean” Post Hurricane Assessments were 6 weeks apart

TEXAS HURRICANE IKEU.H. - M.D. Anderson library

TEXAS HURRICANE IKEHCCS – Northeast Campus Auto Tech

TEXAS HURRICANE IKEUTMB – Galveston: Rebecca Sealy Hospital

Engineers, Architects & General Contractors Agree:

• MAXIMIZE your 1st Event Hidden Damage Recovery.

• Once your Roofing Systems have been “stressed” they will fail at a faster rate & accelerate in future events even if they appear to be minor events.

• ICC concurs after 10 years of Post Event Thermal Mapping across the USA.

RISK MANAGEMENT & Thermal Mapping Cost

Current USA Roofing Cost:1,000,000 SF, Continental US = $25M to $30M

Thermal Mapping Assessment Cost:

5 cents Large Study to 6.5 cents per SF small Study* 1 cent per SF for AIA Scaling* - Always recommended 1.5 Cents per SF for Rooftop AutoCAD Services* Includes a

Prioritized Damage Analysis at No Charge

“For 10 years, I’ve been spending 5 cents/SF with ICC to preserve my roofs instead of $25/SF to

replace them….” Tom Shewan, P.E., FSU

Hurricane Ike Post AssessmentReturn On Investment

• University of Houston: $6M in Visible Damage, with two Blown Off Roofs. $150K invested in ICC’s Post Hurricane Survey results in $6M in Hidden DamageRecovery from FEMA = 40 Times ROI

• Houston Community College System: “Slight” visible Damage, No Blown Off Roofs. $102K invested in ICC’s Post Hurricane Survey results in $5.5M in Hidden Damage Recovery from FEMA = 54 Times ROI

Optional AutoCAD Roof Layers

Rooftop AutoCAD Option Provides Prioritized Damage Analysis

ICC’s Patented Services AreFully Insured

to Perform Envelope Assessments

• General Liability = $1Million, $2M aggregate• Aircraft Liability = $1M aircraft owner, PLUS

$5M non-owned,• Professional Liability = $1M

(Errors & Omissions)• Workers Comp = $.5M or State Statute