DIRECT-VENT FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL ® CDV34(N/P) Save this manual for future reference. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch Do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. WARNING: Improper instal- lation, adjustment, altera- tion, service, or mainte- nance can cause injury or property damage. Refer to this manual for correct in- stallation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier. This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. * Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Installation and service must be performed by a qualified installer, service agency, or the gas supplier. REMOTE REQUIRES TWO 9-VOLT ALKALINE BATTERIES - NOT INCLUDED

Transcript of DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the...

Page 1: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

DIRECT-VENT FIREPLACEOWNER’S OPERATION AND INSTALLATION MANUAL

®

CDV34(N/P)

Save this manual for future reference.

FOR YOUR SAFETYWHAT TO DO IF YOU SMELL GAS• Do not try to light any appliance.• Do not touch any electrical switch• Do not use any phone in your building.• Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.• If you cannot reach your gas supplier, call the fire

department.

WARNING: Improper instal-lation, adjustment, altera-tion, service, or mainte-nance can cause injury orproperty damage. Refer tothis manual for correct in-stallation and operationalprocedures. For assistanceor additional informationconsult a qualified installer,service agency, or the gassupplier.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibitedby state or local codes.* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

WARNING: If the information in this manual is notfollowed exactly, a fire or explosion may result causingproperty damage, personal injury, or loss of life.

FOR YOUR SAFETYDo not store or use gasoline or other flammable vaporsand liquids in the vicinity of this or any other appliance.

— Installation and servicemust be performed by aqualified installer, serviceagency, or the gas supplier.

REMOTE REQUIRESTWO 9-VOLT

ALKALINEBATTERIES -

NOT INCLUDED

Page 2: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

2 105455

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)CDV34(N/P)

SAFETYINFORMATION

1. This appliance is only for use with thetype of gas indicated on the rating plate.This appliance is not convertible for usewith other gases unless a certified kitis used.

2. For propane/LP fireplace, do not placepropane/LP supply tank(s) inside anystructure. Locate propane/LP supplytank(s) outdoors. To prevent perfor-mance problems, do not use propane/LPfuel tank of less than 100 lbs. capacity.

3. If you smell gas• shut off gas supply• do not try to light any appliance• do not touch any electrical switch; do

not use any phone in your building• immediately call your gas supplier

from a neighbor’s phone. Follow thegas supplier's instructions

• if you cannot reach you gas supplier,call the fire department.

4. Never install the fireplace• in a recreational vehicle• where curtains, furniture, clothing, or

other flammable objects are less than42" from the front, top, or sides ofthe fireplace

• in high traffic areas• in windy or drafty areas

5. This fireplace reaches high tempera-tures. Keep children and adults awayfrom hot surfaces to avoid burns or cloth-ing ignition. Fireplace will remain hotfor a time after shutdown. Allow surfacesto cool before touching.

6. Carefully supervise young childrenwhen they are in the room with fireplace.

7. Do not modify this fireplace under anycircumstances. Any parts removed forservicing must be replaced prior to op-erating fireplace.

8. Turn fireplace off and let cool beforeservicing, installing, or repairing. Onlya qualified service person should in-stall, service, or repair this fireplace.Have fireplace inspected annually by aqualified service person.

9. You must keep control compartments,burners, and circulating air passagesclean. More frequent cleaning may beneeded due to excessive lint and dustfrom carpeting, bedding material, etc.Turn off the gas valve and pilot lightbefore cleaning fireplace.

10. Have venting system inspected annu-ally by a qualified service person. Ifneeded, have venting system cleanedor repaired. See Cleaning and Mainte-nance, page 26.

11. Keep the area around your fireplaceclear of combustible materials, gaso-line, and other flammable vapor andliquids. Do not run fireplace wherethese are used or stored. Do not placeitems such as clothing or decorationson or around fireplace.

12. Do not use this fireplace to cook foodor burn paper or other objects.

13. Do not use any solid fuels (wood, coal,paper, cardboard, etc.) in this fireplace.Use only the gas type indicated on fire-place nameplate.

14. This appliance, when installed, must beelectrically grounded in accordancewith local codes or, in the absence oflocal codes, with the National Electri-cal Code, ANS/NFPA 70, or the Cana-dian Electrical Code, CSA C22.1.

15. Do not obstruct the flow of combus-tion and ventilation air in any way. Pro-vide adequate clearances around airopenings into the combustion chamberalong with adequate accessibility clear-ance for servicing and proper operation.

16. Do not install fireplace directly on car-peting, vinyl tile, or any combustiblematerial other than wood. The fireplacemust set on a metal or wood panel ex-tending the full width and depth of thefireplace.

17. Do not use fireplace if any part has beenexposed to or under water. Immediatelycall a qualified service person to ar-range for replacement of the unit.

18. Do not operate fireplace if any log isbroken.

19. Do not use a blower insert, heat ex-changer insert, or other accessory notapproved for use with this fireplace.

20. Do not operate fireplace with glass doorremoved, cracked, or broken.

IMPORTANT: Read this owner’smanual carefully and completelybefore trying to assemble, oper-ate, or service this fireplace. Im-proper use of this fireplace cancause serious injury or death fromburns, fire, explosions, electricalshock, and carbon monoxidepoisoning.

WARNING: Any change tothis fireplace or its controls canbe dangerous.

WARNINGS

DANGER: Carbon monoxidepoisoning may lead to death!

This fireplace is a vented product. Thisfireplace will not produce any gas leakageinto your home if properly installed. Thisfireplace must be properly installed by aqualified service person. The glass doormust be properly seated and sealed. If thisunit is not properly installed by a qualifiedservice person with glass door properlyseated and sealed, gas leakage can occur.

Carbon Monoxide Poisoning: Earlysigns of carbon monoxide poisoning resemblethe flu, with headaches, dizziness, or nausea.If you have these signs, the fireplace may nothave been installed properly. Get fresh airat once! Have fireplace inspected and ser-viced by a qualified service person. Somepeople are more affected by carbon monox-ide than others. These include pregnantwomen, people with heart or lung disease oranemia, those under the influence of alcohol,and those at high altitudes.

Propane/LP gas and natural gas are bothodorless. An odor-making agent is added toeach of these gases. The odor helps youdetect a gas leak. However, the odor addedto these gases can fade. Gas may be presenteven though no odor exists.

Make certain you read and understand allWarnings. Keep this manual for reference.It is your guide to safe and proper operationof this fireplace.

Page 3: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

3105455

OWNER’S MANUAL

PRODUCTIDENTIFICATION Install and use fireplace with care. Follow

all local codes. In the absence to local codes,use the current National Fuel Gas CodeANS Z223.1, also known as NFPA 54*(USA) or the current CAN/CGA-B149[.1 or.2] Installation Codes (Canada).

*Available from:

American National Standards Institute, Inc.1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.Batterymarch ParkQuincy, MA 02269

LOCAL CODES

PRODUCTFEATURESOPERATIONThis direct-vent fireplace is clean burningand vents easily through outside walls orvertically using outside air for combustion.Heat is generated by both realistic flamesand glowing embers. When used withoutthe blower accessory, the fireplace requiresno electricity making it ideal for emergencybackup heat.

PIEZO IGNITORThis fireplace has a piezo ignitor. This sys-tem requires no matches, batteries, or othersources to light fireplace.

Figure 1 - Comfort Glow Direct-Vent Fireplace CDV Series

Glass DoorAssembly

Blower Adjustment(Optional Installation)

ON/OFF Remote Switch(Optional Installation)

Piezo IgnitorValve

PilotAssembly

Log Set

GrateAssembly

Lava Rock

Glowing Embers

Top LouverPanel

Lower Louver Panel

Vent OpeningNailingFlange Standoff

RearBurner

GLOSSARY OFTERMSChase - A boxlike enclosure to protectventing from the elements when the ventingrun is on the outside of a structure.

Mastic - A pliable sealant for use aroundthe vent terminal.

Snorkel Termination - A box that raisesthe horizontal termination above groundlevel clearances.

Vent Terminal - Mounted on an outsidewall or roof to separate the inlet and outlet ofthe vent system and protect it from weather.

Vinyl Siding Standoff - A metal box thatseparates the vent cap from vinyl siding.

Wall Thimble/Firestop - A metal plateused to secure the vent pipe when it passesthrough a wall or ceiling.

Front Burner

Page 4: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

4 105455

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)CDV34(N/P)

Fireplace size D x FW x RW34" 18 1/2" 34" 14"

PRE-INSTALLATIONPREPARATIONLOCATION AND SPACEREQUIREMENTSDetermine the safest and most efficient loca-tion for your Comfort Glow direct-vent fire-place. Make sure that rafters and wall studsare not in the way of the venting system.Choose a location where the heat output isnot affected by drafts, air conditioning ducts,windows or doors. Figure 2 shows somecommon locations. Read all venting infor-mation in this manual. Be aware of all re-strictions and precautions before decidingthe exact location for your fireplace.

When deciding the location of your fire-place, follow these rules:

1. Do not connect this fireplace to a chim-ney flue serving a separate solid-fuelburning fireplace or appliance.

2. Due to high temperatures, do not lo-cate this fireplace in high traffic areasor near furniture or draperies.

3. Proper clearances must be maintained.

4. If your fireplace is to be installed di-rectly on carpeting, vinyl tile, or anycombustible material other than wood,it must be installed on a metal or woodpanel extending the full width anddepth of the fireplace. See Figure 3.

20"

34 3/4"

5/8" for drywall facing

Must maintain a minimum 1" clearance to combustibles

34 1/2"

34 3/4"

20" Vertical Termination19" Horizontal Termination

CLEARANCESMinimum clearances to combustibles forthe fireplace are as follows:

Back, and sides 0"/mmPerpendicular walls 6" (152mm)Floor 0"/mmCeiling to louver opening 42" (1067mm)Front 36" (914mm)Top of Standoffs 0"/mm

See General Venting on page 5 for specificventing clearances.

FRAMING AND FINISHINGFigures 4 and 5 show typical framing of thisfireplace. Figure 6 on page 5 shows framingfor corner installation. All minimum clear-ances must be met. Do not install fireplacedirectly on carpeting, vinyl tile, or any com-bustible material other than wood. The fire-place must set on a metal or wood panelextending the full width and depth of thefireplace.

See Accessories on page 31 for mantel kitsavailable for this fireplace. If you are usinga separate combustible mantel piece, referto Figure 7 on page 5 for proper installationheight. You can install noncombustiblemantels at any height above the fireplace.

Figure 2 - Common Fireplace Locations

Figure 4 - Framing Clearances for Installation Against an Exterior Wall

Figure 5 - Framing Clearances for TypicalFireplace Installation

Flush with a wall

Through exterior wallenclosed in a chase

Cornerinstallation

Figure 3 - Fireplace Bottom Dimensions

D

RW

FW

Page 5: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

5105455

OWNER’S MANUAL

29"

13"

12 5/8"

34 1/4"

34 3/4"

58"

9 1/4" 41"

Nailing Tabs

PRE-INSTALLATIONPREPARATIONContinued

Figure 6 - Framing Clearances for Corner Installation

LOCATION OF VENTTERMINATIONWhen locating vent termination, it is impor-tant to observe the minimum clearancesshown in Figure 8, page 6. You will avoidextra framing by positioning your fireplaceagainst an already existing framing mem-ber. The sides of the fireplace may be posi-tioned directly against combustible walls.

*Check with local codes or with the currentCAN/CGA B149 [.1 or .2] Installation Codesfor Canada or the USA Installations followthe current National Fuel Gas Code, ANSZ223.1, also known as NFPA 54.

These models are approved for use withSimpson Dura-Vent 6 5/8" direct-vent pipecomponents and terminations as well asboth flex and rigid Comfort Glow ventcomponents.

Your fireplace is approved to be vented eitherthrough the side wall, or vertically using thefollowing guidelines:

• Only use Comfort Glow or Simpson Dura-Vent GS venting components or kits spe-cifically approved for this fireplace.

• Minimum clearance between vent pipesand combustible materials is 1" (25 mm),except where stated otherwise.

• Combustible material may be flush withthe top front of fireplace with a maxi-mum thickness of 3/4".

• Do not recess venting terminals into awall or siding.

• Install horizontal venting with a 1/4" risefor every 12" of run toward the termination.

• You may paint the vent terminal with450ºF (232ºC) heat-resistant paint to co-ordinate with the exterior finish.

• There must not be any obstruction suchas bushes, garden sheds, fences, decks,or utility buildings within 24" from thefront of the termination cap.

• Do not locate termination cap where ex-cessive snow or ice build up may occur.Be sure to clear vent termination area af-ter snow falls to prevent accidental block-age of venting system. When using snowblowers, do not direct snow towards venttermination area.

GENERAL VENTING

C

B

A

DE

FG

Top of Louver Opening

3

2

1

4

5

6

7

Wall

Figure 7 - Clearances for Combustible Mantels

Ref. Mantel Depth Ref. Mantel from Topof Louver Opening

1 14" (356mm) A 16" (406mm)

2 12" (305mm) B 14" (356mm)

3 10" (254mm) C 12" (305mm)

4 8" (203mm) D 10" (254mm)

5 6" (152mm) E 8" (203mm)

6 4" (101mm) F 6" (152mm)

7 2" (51mm) G 4" (101mm)

Continued

Page 6: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

6 105455

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)CDV34(N/P)

FixedClosed Openable Fixed

ClosedOpenable

V

V

V

V

V V

V

V

X

X

V X

G

G

JF

B

B

K

N

H

I

A

N

E

L

D

B

M

A

C

B

V

V

A

G

G

B

TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA(TERMINATION PROHIBITED)

A = clearance above grade, veranda, porch, deck, or balcony [*12 inches (305mm) minimum]

B = clearance to window or door that may be opened [12 inches (305mm) minimum]

C = clearance to permanently closed window [minimum 12 inches (305mm) recommended to prevent condensation on window]

D = vertical clearance to ventilated soffit located above the terminalwithin a horizontal distance of 24 inches (610mm) from thecenter-line of the terminal [18 inches (457mm) minimum]

E = clearance to unventilated soffit [12 inches (305mm) minimum]F = clearance to outside corner (see below)G = clearance to inside corner (see below)H = *not to be installed above a meter/regulator assembly within

36 inches (914mm) horizontally from the center-line of the regulator

I = clearance to service regulator vent outlet [*72 inches (1829mm)minimum]

J = clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [*12 inches (305mm) minimum]

K = clearance to a mechanical air supply inlet [*72 inches (1829mm)minimum]

L = † clearance above paved side-walk or a paved driveway located on public property [*84 inches (2133mm) minimum]

M = clearance under veranda, porch, deck [*12 inches (305mm) minimum ‡]N = clearance above a roof shall extend a minimum of 24 inches (610mm)

above the highest point when it passes through the roof surface andany other obstruction within a horizontal distance of 18 inches (457mm)

† vent shall not terminate directly above a side-walk or paved driveway which is located between twosingle family dwellings and serves both dwellings*

‡ only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor** as specified in CAN/SGA B149 (.1 or .2) Installation Codes (1991) for Canada or for U.S.A. installation follow

the current National Fuel Gas Code, ANS Z223.1Note: Local codes or regulations may require different clearances

A = 6" (152mm)

Inside Corner

V

B

E

V

B = 6" (152mm)

C = Maximum depth of 48" (1219mm) forrecessed location

D = Minimum width for back wall of recessed location -Combustible - 38" (965mm)Noncombustible - 24" (610mm)

E = Clearance from corner in recessed location-Combustible - 6" (152mm)Noncombustible - 2" (51mm)

Outside Corner Recessed Location

G

H

G = Combustible 24" (610mm)Noncombustible 18" (457mm)

Balcony with No Side Wall

V

J

Combustible & NoncombustibleH = 24" (610mm)J = 20" (508mm)

Balcony with Perpendicular Side Wall

C

D

C

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Figure 8 - Minimum Clearances for Vent Terminations

GENERAL VENTING Continued

Page 7: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

7105455

OWNER’S MANUAL

WARNING: Read all instruc-tions completely and thoroughlybefore attempting installation. Fail-ure to do so could result in seriousinjury, property damage or loss oflife. Operation of improperly in-stalled and maintained venting sys-tem could result in serious injury,property damage or loss of life.

WARNING: Seal all of the con-nections with high temperaturesilicone (600 °F/316° C) every timea vent connection is made. Be-fore joining elbows and pipes,apply a bead of high temperaturesilicone sealant (GE RTV 106/Loctite RTV 81585) to the end ofthe elbow or pipe. High tempera-ture silicone must also be used toreseal any connections aftermaintenance to venting system.

NOTICE: Failure to follow theseinstructions will void the warranty.

INSTALLATION PRECAUTIONSConsult local building codes before beginningthe installation. The installer must make sureto select the proper vent system for installa-tion. Before installing vent kit, the installermust read this fireplace manual and vent kitinstructions.

Only a qualified service person should in-stall venting system. The installer must fol-low these safety rules:

• Wear gloves and safety glasses forprotection

• Use extreme caution when using laddersor when on roof tops

• Be aware of electrical wiring locationsin walls and ceilings

The following actions will void the war-ranty on your venting system:

• Installation of any damaged ventingcomponent

• Unauthorized modification of the vent-ing system

VENTINGINSTALLATION

WARNING: This gas fireplaceand vent assembly must bevented directly to the outside.The venting system must NEVERbe attached to a chimney servinga separate solid fuel burning ap-pliance. Each gas appliance mustuse a separate vent system. Donot use common vent systems.

WARNING: Horizontal sec-tions of this vent system requirea minimum clearance of 2" fromthe top of the pipe and 1" mini-mum to the sides and bottom.Vertical sections of this systemrequire a minimum of 1" clear-ance to combustible materials onall sides of the pipe.

• Installation of any component part notmanufactured or approved by DESAInternational

• Installation other than as instructed bythese instructions

INSTALLATION PLANNINGThere are two basic types of direct-ventinstallation:

• Horizontal Termination

• Vertical Termination

It is important to select the proper length ofvent pipe for the type of termination youchoose. It is also important to note the wallthickness.

For Horizontal Termination: Select theamount of vertical rise desired. The horizon-tal run of venting must have 1/4" rise forevery 12" of run towards the termination.

NOTICE: Treatment of firestopsand construction of the chase mayvary from building type to buildingtype. These instructions are notsubstitutes for the requirementsof local building codes. You mustfollow all local building codes .

Note: When installing in a chase, you shouldinsulate the chase as you would the outsidewalls of your home. This is especially im-portant in cold climates. Minimum clear-ance between vent pipes and combustiblematerials such as insulation is 1".

After framing the chase (see Framing andFinishing on page 4) install the vent systemby following the installation instructions.

Installing Vent System in a Chase

A chase is a vertical boxlike structure builtto enclose venting that runs along the out-side of a building. A chase is not required forsuch venting.

Continued

WARNING: Never run the ventdownward as this may cause ex-cessive temperatures whichcould cause a fire.

You may use one or two 90° elbows in thisvent configuration. See Horizontal Termina-tion Configurations on pages 10 and 11.

For Vertical Termination: Measure thedistance from the fireplace flue outlet to theceiling. Add the ceiling thickness, the verti-cal rise in an attic or second story, and allowfor sufficient vent height above the roofline.

You may use one or two 90° elbows in thisvent configuration. See Vertical TerminationConfigurations on pages 13 and 14.

Note: You may use two 45° elbows in placeof a 90° elbow. You must follow rise to runratios when using 45° elbows.

For two-story applications, firestops are re-quired at each floor level. If an offset isneeded in the attic, additional pipe and el-bows will be required.

You may use a chase with a vent terminationwith exposed pipe on the exterior of the house.See Installing Vent System in a Chase, below.

Your Comfort Glow direct-vent fireplacehas been tested for a minimum 3' rise with amaximum 10" wall thickness. The maxi-mum horizontal run is 20' with 8' verticalrise (see Installation for Horizontal Termi-nation, page 8). The maximum vertical runis 30' (see Installation for Vertical Termina-tion, page 12).

It is very important that the venting systemmaintain its balance between the combus-tion air intake and the flue gas exhaust.Certain limitations apply to vent configura-tions and must be strictly followed.

Page 8: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

8 105455

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)CDV34(N/P)

INSTALLATION FORHORIZONTAL TERMINATION1. Determine the route your horizontal

venting will take. Note: The locationof the horizontal vent termination on theexterior wall must meet all local andnational building codes and must not beeasily blocked or obstructed.

Snorkel terminations are available forterminations requiring a vertical rise onthe exterior of the building (see Figures9 and 10). Snorkel kit CSVK is alsoavailable (see page 15). Follow the sameinstallation procedures as used for stan-dard horizontal terminations. If install-ing the snorkel termination below grade(basement applications), you must pro-vide proper drainage to prevent waterfrom entering the snorkel termination(see Figure 10). Do not back fill aroundthe snorkel termination.

2. Rigid vent pipes and fittings have spe-cial twist-lock connections. Assemblethe desired combination of pipe and el-bows to the appliance adaptor with pipeseams oriented towards the wall or floor.

Twist-lock Procedure: The femaleends of the pipes and fittings have fourlocking lugs (indentations). These lugswill slide straight into matching slots onthe male ends of adjacent pipes and fit-tings. (All connections must be sealedwith high temperature silicone sealantas specified in the second warning state-ment on page 7.) Push the pipe sectionstogether and twist one section clockwiseapproximately one-quarter turn until thesections are fully locked. See Figure 11,page 9. Note: Horizontal runs of ventmust be supported every three feet. Usewall straps for this purpose.

Flexible vent pipe must be installed withspacer springs every 12". See Figure 11,page 9. All connections must be clampedtightly and sealed with high temperaturesilicone sealant as specified in the sec-ond warning statement on page 7.

VENTINGINSTALLATIONContinued

WARNING: Do not recess ventterminal into a wall or siding.

Figure 10 - Snorkel Termination with Drainage Pipe��������������������������������������������������������������������������������������������������

12" Minimum

Figure 9 - Snorkel Termination��������������������

Snorkel

12" Minimum

Snorkel

AdequateDrainage

Page 9: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

9105455

OWNER’S MANUAL

VENTINGINSTALLATIONContinued

(FramingDetail)

10"(254mm)

10"(254mm)

7 1/2"(190mm)

Vent OpeningCombustible Wall

Vent OpeningNoncombustible Wall

Figure 12 - Vent Opening Requirements

Continued

3. Attach vent pipe assembly to the fire-place. Set fireplace in front of it’s perma-nent location to insure minimum clear-ances. Mark the wall for a 10" square hole(for noncombustible material such asmasonry block or concrete, a 7 1/2" diam-eter hole is acceptable). See Figure 12.The center of the hole should line up withthe center-line of the horizontal rigid ventpipe. Cut a 10"x10" (254mm x 254mm)square hole through combustible exteriorwall (7 1/2" [190mm] diameter hole if non-combustible). Frame as necessary (seeFigure 12).

UP

Figure 14 - Installing Vinyl Siding Standoff

Cut Vinyl SidingAway to FitStandoff

Wood Screw

NutBolt

Standoff

Vent Cap

Figure 11 - Vent Pipe Connections

FemaleLockingLugs

MaleSlots

Rigid Vent Pipe Flexible Vent Pipe

SpacerSpring

4" Clamp

7" Clamp

4" FlexPipe

7" FlexPipe

Apply Masticto All Four Sides

Figure 13 - Installing Horizontal Vent Cap

UP

WoodScrew

Vent Cap

Apply Masticto All FourSides

WARNING: Do not recess venttermination in to any wall. Thiswill cause a fire hazard.

4. Apply a bead of non-hardening masticaround the outside edge of the vent cap.Position the vent cap in the center ofthe 7 1/2" or 10" hole on the exteriorwall with the arrow on the vent cappointing up. Insure proper clearance of1" to combustibles is maintained. At-tach the vent cap with four wood screwssupplied (see Figure 13). Note: Re-place the wood screws with appropri-ate fasteners for stucco, brick, concrete,or other types of siding.

For vinyl siding use vinyl siding stand-offs between vent cap and exterior wall.The vinyl siding standoff prevents ex-cessive heat from melting the vinyl sid-ing material. Bolt the vent cap to thestandoff. Apply non-hardening masticaround outside edge of the standoff in-stead of the vent cap assembly. Usewood screws provided to attach thestandoff. See Figure 14.

5. Slide the wall thimble over the vent pipebefore connecting the horizontal run tothe vent cap (see Figure 15).

6. Carefully move the fireplace with ventassembly attached toward the wall andinsert the vent pipe into the horizontaltermination. The pipe overlap shouldbe a minimum of 1 1/4". Apply siliconeto the connection. Fasten all vent con-nections with screws provided. Referto Fireplace Installation on page 16 forinstructions on securing unit to fram-ing or floor.

7. Slide the wall thimble against the inte-rior wall surface and attach with screwsprovided (see Figure 15).

Vent Cap(HorizontalTermination)

Interior WallSurface

WallThimble

HorizontalVent Pipe

Figure 15 - Connecting Vent Cap withHorizontal Vent Pipe

Screw

Page 10: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

10 105455

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)CDV34(N/P)

VENTINGINSTALLATIONContinued

UP

UP

Horizontal Venting

Vertical (V) Horizontal (H)

37" min. 10" max.

Figure 16 - Horizontal TerminationConfiguration for Rigid Venting

Figure 17 - Horizontal Termination Configuration for Rigid Venting Using One90° Elbow

Figure 18 - Horizontal Termination Using Flexible Venting

Horizontal Venting

Vertical (V) Horizontal (H)

44" min. 29" max.(30° and 90° only, no vertical pipe)

55" min. 41" max.(30° elbow, 1' vertical pipe, 90° elbow)

67" min. 60" max.79" min. 84" max.96" min. 20' max.

Note: This configuration for use withcorner installation.

UP

Horizontal Venting

See information inFigures 16 and 17 forVertical(V) andHorizontal(H) maxi-mums and minimums.The same amountsapply for flexibleventing.

CGFVK Vent KitShown (recommendedfor use with cabinetmantels)

CBVK Vent Kit Shown

Horizontal TerminationConfigurations

Figures 16 through 20 show different con-figurations for venting with horizontal ter-mination. Each figure includes a chart withvertical minimum/maximum and horizon-tal maximum dimensions which must bemet. All connections must be sealed withhigh temperature silicone sealant as speci-fied in the second warning statement onpage 7. All horizontal terminations require1/4" rise per 12" of horizontal run.

Page 11: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

11105455

OWNER’S MANUAL

VENTINGINSTALLATIONContinued

UP

Venting with Two 90 ° Elbows

Vertical (V) Horizontal (H1) Horizontal (H

1) +

Horizontal (H2)

5' min. 2' max. 6' max.6' min. 4' max. 12' max.7' min. 6' max. 18' max.8' min. 8' min. 20' max.

20' max. 8' max. 20' max.

Venting with Two 90 ° Elbows

Vertical (V) Horizontal (H1) +

Horizontal (H2)

5' min. 6' max.6' min. 12' max.7' min. 18' max.8' min. 20' max.

20' max. 20' max.

Figure 19 - Horizontal Termination Configuration for Rigid Venting Using Two 90 ° Elbows

Figure 20 - Horizontal Termination Configuration for Rigid Venting Using Two 90 ° Elbows with Termination at 90 ° with Fireplace

Continued

Page 12: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

12 105455

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)CDV34(N/P)

4. Connect a section of pipe and extendup through the hole.

Note: If an offset is needed to avoidobstructions, you must support the ventpipe every 3 feet. Use wall straps forthis purpose (see Figure 21). Wheneverpossible, use 45° elbows instead of 90°elbows. The 45° elbow offers less re-striction to the flow of the flue gasesand intake air.

5. Place the flashing over the pipesection(s) extending through the roof.Secure the base of the flashing to theroof and framing with roofing nails. Besure roofing material overlaps the topedge of the flashing as shown in Figure21. There must be a 1" clearance fromthe vent pipe to combustible materials.

6. Continue to add pipe sections until theheight of the vent cap meets the mini-mum building code requirements de-scribed in Figure 8 on page 6. Note: Youmust increase vent height for steep roofpitches. Nearby trees, adjoining rooflines,steep pitched roofs, and other similar fac-tors may cause poor draft or down-draft-ing in high winds. Increasing the ventheight may solve this problem.

7. Twist-lock the vent cap onto the lastsection of vent pipe and seal with hightemperature silicone sealant as speci-fied in the second warning statementon page 7.

Note: If the vent pipe passes through anyoccupied areas above the first floor, includingstorage spaces and closets, you must enclosepipe. You may frame and sheetrock the enclo-sure with standard construction material. Makesure and meet the minimum allowable clear-ances to combustibles. Do not fill any of therequired air spaces with insulation.

Cathedral Ceiling Installation1. Remove shingles or other roof cover-

ing as necessary to cut the rectangularhole for the support box. Mark the out-line of the cathedral ceiling support boxon the roof sheathing using the locat-ing hole as a center point.

2. Cut the hole 1/8" larger than the sup-port box outline (see Figure 23, page 13).

INSTALLATION FORVERTICAL TERMINATION1. Determine the route your vertical vent-

ing will take. If ceiling joists, roofrafters, or other framing will obstructthe venting system, consider an offset(see Figure 21) to avoid cuttingloadbearing members. Note: Pay spe-cial attention to these installation in-structions for required clearances (airspace) to combustibles when passingthrough ceilings, walls, roofs, enclo-sures, attic rafters, etc. Do not pack airspaces with insulation. Also note maxi-mum vertical rise of the venting sys-tem and any maximum horizontal off-set limitations. Offsets must fall withinthe parameters shown in Figure 8 onpage 6.

2. Set the fireplace in desired location.Drop a plumb line down from the ceil-ing to the position of the fireplace exitflue. Mark the center point where thevent will penetrate the ceiling. Drill asmall locating hole at this point.

Drop a plumb line from the inside ofthe roof to the locating hole in the ceil-ing. Mark the center point where thevent will penetrate the roof. Drill asmall locating hole at this point.

Flat Ceiling Installation1. Cut a 10" square hole in the ceiling us-

ing the locating hole as a center point.The opening should be framed to10"x10" (254mm x 254mm) inside di-mensions, as shown in Figure 12 onpage 9 using framing lumber the samesize as the ceiling joists. If the areaabove the ceiling is an insulated ceil-ing or a room, nail firestop from thetop side. This prevents loose insulationfrom falling into the required clearancespace. Otherwise, install firestop belowthe framed hole. The firestop should beinstalled with no less than three nailsper side (see Figure 22).

2. Assemble the desired lengths of pipeand elbows necessary to reach from thefireplace flue up through the firestop.All connections must be sealed withhigh temperature silicone sealant asspecified in the second warning state-ment on page 7. Be sure all pipe andelbow connections are fully twist-locked (see Figure 11, page 9).

3. Cut a hole in the roof using the locatinghole as a center point. (Cover any ex-posed open vent pipes before cuttinghole in roof.) The 10"x10" hole mustbe measured on the horizontal; actuallength may be larger depending on thepitch of the roof. There must be a 1"clearance from the vent pipe to combus-tible materials. Frame the opening asshown in Figure 12 on page 9.

VENTINGINSTALLATIONContinued

Figure 21 - Offset with Wall Strap and 45 °Elbows

45° Elbow

Wall Strap

RoofFlashing

Ceiling Firestop

Figure 22 - Installing Firestop

If area above is not a room, installfirestop below framed hole.

If area above is a room, install firestopabove framed hole.

Page 13: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

13105455

OWNER’S MANUAL

VENTINGINSTALLATIONContinued

Continued

Figure 23 - Cathedral Ceiling SupportBox Installation

Non-hardening Mastic under alledges of support box before nailing

Figure 24 - Installed Cathedral CeilingSupport Box

Vertical Termination Configurations

Figures 25 through 28 show four different configurations for vertical termination. Allconnections must be sealed with high temperature silicone sealant as specified in the secondwarning statement on page 7.

Venting with Two 90 ° Elbow s

Vertical (V) Horizontal (H1) +

Horizontal (H2)

5' min. 2' max.6' min. 4' max.7' min. 6' max.8' min. 8' max.

20' max. 8' max.

Figure 25 - Vertical Rigid Venting Configuration Using Two 90 ° Elbows with TwoHorizontal Runs

3. Lower the support box through the holein the roof until the bottom of the boxextends at least 2" below the ceiling(see Figure 23). Align the support boxvertically and horizontally using a level.Temporarily tack the support box inplace through the inside walls and intothe roof sheathing.

4. Using tin snips, cut the support box fromthe top corners down to the roofline andfold the resulting flaps over the roofsheathing (see Figure 24). Apply a beadof non-hardening mastic around the topedges of the support box to make a sealbetween the box and the roof. Nail inplace with roofing nails. Remove anycombustible material that might be in-side of the support box.

5. Complete the cathedral ceiling instal-lation by following the same proce-dures outlined in steps 2 through 7 forFlat Ceiling Installation, page 12.

Venting with One 90 ° Elbow

Vertical (V) Horizontal (H)

5' min. 2' max.6' min. 4' max.7' min. 6' max.8' min. 8' max.

20' max. 8' max.

Figure 26 - Vertical Rigid Venting Configuration Using One 90 ° Elbow

Cut hole 1/8" larger than supportbox when projected onto roofline

2" minimum belowfinished ceiling

Cathedral ceilingsupport box

Level

Note: Restrictor must beinstalled in all verticalinstallations.

Note: Restrictor must beinstalled in all verticalinstallations.

Page 14: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

14 105455

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)CDV34(N/P)

Vertical Venting

V = 30' max.

Figure 28 - Vertical Rigid VentingConfiguration With No Horizontal Run

VENTINGINSTALLATIONContinued

Venting with Two 90 ° Elbows

Vertical (V1) Horizontal (H)

5' min. 6' max.6' min. 12' max.7' min. 18' max.8' min. 20' max.

Note: Vertical (V1) +

Vertical (V2) = 20' max.

Figure 27 - Vertical Rigid Venting Configuration Using Two 90 ° Elbows

CRVF Kit Shown

Note: Restrictor must beinstalled in all verticalinstallations.

Page 15: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

15105455

OWNER’S MANUAL

Number DescriptionComfort Glow Flexible Venting

Simpson Dura-Vent GS 4" x 6 5/8 "Number DescriptionAvailable from DESA International:CSD2040 Simpson Dura-Vent GS

30° Elbow (Qty 1)CSD2050 Simpson Dura-Vent GS

60° Elbow (Qty 1)Available from SimpsonDura-Vent Only:902 7" x 48" Pipe903 7" x 36" Pipe904 7" x 24" Pipe906 7" x 12" Pipe907 7" x 9" Pipe908 7" x 6" Pipe911 7" Adjustable (11"-14 5/8") Pipe940 Wall Thimble941 Cathedral Ceiling Support Box943 Roof Flashing 0/12-6/12943S Roof Flashing 7/12-12/12945 7" x 45° Elbow950 Vinyl Siding Standoff953 Storm Collar963 Ceiling Firestop981 36" Snorkel Termination984 Horizontal Termination Vent Cap988 Wall Strap990 7" x 90° Elbow991 Vertical High Wind Termination

VENTINGINSTALLATIONContinued

HIGH ALTITUDE INSTALLATIONYour Comfort Glow direct-vent fireplacehas been AGA tested and approved forelevations from 0-2000 feet and CGA certi-fied for elevations from 0-4500 feet.

When installing this fireplace at an elevationabove 2000 feet (in the USA), you may needto decrease the input rating by changing theexisting burner orifice to a smaller size. Re-duce input 4% for each 1000 feet above sealevel. Check with your local gas company forproper orifice size identification.

When installing this fireplace at an eleva-tion above 4500 feet (in Canada), checkwith local authorities.

Consult your local gas company to help de-termine the proper orifice for your location.

For assistance with any high altitude instal-lation contact DESA International’s Tech-nical Services Department at 1-800-DESA-LOG (1-800-337-2564).

PARTS LISTS FOR VENTINGKITS AND COMPONENTSComfort Glow Rigid VentingNumber DescriptionCBGFVK Basic Ground Floor Rigid

Vent KitIncludes: 7" x 60° Elbow, ExtendedAdjustable Horizontal Termina-tion, Wall Thimble and 14 Screws

CBVK Basement Rigid Vent KitIncludes: 7" x 30° Elbow, 7" x 4'Galvanized Pipe, 7" x 90° Elbow,7" Adjustable Galvanized Pipe (7-12"), Wall Thimble, HorizontalTermination, RTV Silicone and 20Screws

CBVKA Basement Rigid Vent Kit (Special)Includes: 7" x 30° Elbow, 7" x 4'Galvanized Pipe, 7" x 90° Elbow,7" Adjustable Galvanized Pipe (7-12"), RTV Silicone and 20 Screws

Number DescriptionCCVK Corner Vent Kit

Includes: 7" x 30° Elbow, 7" x 90°Elbow, 7" Adjustable GalvanizedPipe (7-12"), Horizontal termina-tion, wall thimble, 6" pipe, RTVsilicone and 20 screws

CSVK Snorkel Rigid Vent KitIncludes: 7" x 30° Elbow, 7" x 4'Galvanized Pipe, 7" x 90° Elbow, 7"Adjustable Galvanized Pipe (7-12"),Wall Thimble, 36" Snorkel Termi-nation, RTV Silicone and 28 Screws

CRVF Roof Rigid Vent KitIncludes: Flue Restrictor, StormCollar, 7" x 30° Elbow, 7" x 4'Galvanized Pipe, 7" x 2' GalvanizedPipe, 7" Adjustable Galvanized Pipe(7-12"), Firestop Support, RoofFlashing, RTV Silicone, VerticalTermination, and 26 screws.

CD1000 7" x 12" Galvanized Coaxial Pipe(Qty 1)

CD1010 7" x 24" Galvanized Coaxial Pipe(Qty 1)

CD1020 7" x 48" Galvanized Coaxial Pipe(Qty 1)

CD1030 7" Adjustable (7-12") GalvanizedCoaxial Pipe (Qty 1)

CD1050 7" x 6" Galvanized Coaxial Pipe(Qty 1)

CD2000 7" x 90° Elbow (Qty 1)

CD2010 7" x 45° Elbow (Qty 1)

CD2020 7" x 30° Elbow (Qty 1)

CD2030 7" x 60° Elbow (Qty 1)

CD3000 Wall Strap/Offset Support (Qty 1)

CD3010 Storm Collar (Qty 1)

CD3020 Wall Thimble (Qty 1)

CD3040 Vertical Termination Cap

CD3050 Vertical Restrictor (Qty 1)

CD3060 Ceiling Firestop/Support (Qty 1)

CD3070 Rectangular Horizontal RigidVent Termination Cap

CD3090 Cathedral Ceiling Support Box

CD4000 Roof Flashing 6/12-9/12

CD4010 Roof Flashing 9/12-12/12

CD5000 Vinyl Siding Standoff (Qty 1)

Comfort Glow Rigid Venting (Cont.)

CBFGFVK Basic Flex Ground Floor Vent KitIncludes: Flex Adapter, 7" x 2'Flexible Pipe, 4" x 2' FlexiblePipe, Wall Thimble, HorizontalTermination, (2) Spacer Springs, (2) 4" Hose Clamps, (2) 7" HoseClamps, and 10 Screws

CFGFVK Flex Ground Floor Vent KitIncludes: Flex Adapter, 7" x 4'Flexible Pipe, 4" x 4' FlexiblePipe, Wall Thimble, HorizontalTermination, (4) Spacer Springs,(2) 4" Hose Clamps, (2) 7" HoseClamps, RTV Silicone, and10 Screws

CD1040 7" x 25' Coaxial Flex Pipe withSpacer Springs

CD3080 Rectangular Horizontal FlexTermination Cap

CD4020 Flex Connector (Qty 1)CD4030 Flex Wall Thimble (Qty 1)CD4040 4" Clamp (Qty 1)CD4050 7" Clamp (Qty 1)

Page 16: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

16 105455

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)CDV34(N/P)

INSTALLING OPTIONALBLOWER ACCESSORY

IMPORTANT: For clarity, gas valve assem-bly and grate/burner assembly are not shownin Figures 30 through 33, page 17. They will,however, be in your fireplace when you areinstalling the blower. Also for clarity thefirebox is shown with dotted lines.

1. Open lower louver panel or remove foreasier access.

2. Place the blower against the lower rearwall of firebox outer wrapper with theexhaust port directed upward. Align theholes in the top mounting tabs of blowerwith holes in wall of wrapper (see Fig-ure 30, page 17). Using the two screwsprovided, mount blower and tightenscrews securely.

Note: For CDA3620T, make sure thethermal switch is comfortably under theback of the firebox as shown in Figure31, page 17.

3. Be sure to securely attach all wire ter-minals to terminals on blower motor(and thermal switch where applicable)and that the screw retaining the greenground wire is tight.

4. Remove screws securing the plate to thebottom of the firebox and set aside.

5. Place speed control against back of thisplate and push the plastic control shaftthrough opening (see Figure 32, page 17).

6. While supporting speed control, securecontrol shaft with lock nut by pushing andturning lock nut with pliers clockwiseuntil tight against the plate. Place controlknob provided onto shaft (see Figure 32,page 17).

7. Replace plate containing switch andtighten screws securely.

NOTICE: If installing blower in anexisting fireplace with gas con-nections, shut off gas supply anddisconnect heater from gas sup-ply. Contact a qualified serviceperson to do this.

CHECK GAS TYPEUse proper gas type for the fireplace unityou are installing. If you have conflictinggas types, do not install fireplace. See re-tailer where you purchased the fireplace forproper fireplace according to your gas type.

FIREPLACEINSTALLATION

NOTICE: This heater is intendedfor use as supplemental heat. Usethis heater along with your pri-mary heating system. Do not in-stall this heater as your primaryheat source. If you have a centralheating system, you may runsystem’s circulating blower whileusing heater. This will help circu-late the heat throughout thehouse. In the event of a poweroutage, you can use this heateras your primary heat source.

WARNING: A qualified ser-vice person must install fireplace.Follow all local codes.

CAUTION: This fireplace cre-ates warm air currents. These cur-rents move heat to wall surfacesnext to fireplace. Installing fire-place next to vinyl or cloth wallcoverings or operating fireplacewhere impurities (such as to-bacco smoke, aromatic candles,cleaning fluids, oil or kerosenelamps, etc.) in the air exist, maydiscolor walls.

Note: Your fireplace is designed to be usedin zero clearance installations. Wall or fram-ing material can be placed directly againstany exterior surface on the rear, sides, or topof your fireplace, except where standoffspacers are integrally attached. If standoffspacers are attached to your fireplace, thesespacers can be placed directly against wallor framing material. See framing details onpage 4.

Place the fireplace into position and shimwith noncombustible material if needed.Nail the side flanges to the framing to securethe unit in place. There are two floor brack-ets included with each unit. Use these as analternative method of securing the fireplace.

IMPORTANT: Make sure fireplace is levelbefore securing. If fireplace is not level itwill not work properly.

Attaching Thermal Switch toCDA3620T Thermostatically-Controlled Blower

When installing the CDA3620T thermo-statically-controlled blower accessory, youmust first secure the thermal switch to theblower.

1. Remove the two hex head screws on theblower assembly as shown in Figure 29.

2. Place the green wire between the bot-tom hole on the thermal switch bracketand the bottom hole on the blower as-sembly. Insert one of the hex screwsinto all three pieces and tighten.

3. Insert the top screw through the ther-mal switch bracket and into the blowerassembly. Tighten screw.

4. Connect the blue wire on the blowerassembly to the right side of the ther-mal switch.

5. Connect the black wire to the left sideof the thermal switch.

Installing GA3750/CDA3620TBlowers

Figure 29 - Attaching Thermal Switch to DA3610T Thermostatically-ControlledBlower Accessory

Blower Assembly

Blue Wire

Green Wire

Black Wire

White Wire

Hex HeadScrews

Thermal Switchwith Bracket

Page 17: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

17105455

OWNER’S MANUAL

FIREPLACEINSTALLATIONContinued

WARNING: Never touch theblower wheel while in operation.

10. Peel off the backing paper and stick thesupplied wiring diagram decal on thefirebox bottom approximately 3" to theright of the blower speed controlbracket (Figure 33).

WARNING: Failure to positionthe parts in accordance with sup-plied diagrams or failure to useonly parts specifically approvedwith this heater may result in dam-age or personal injury.

11. Connect or reconnect gas supply to fire-place per Connecting Fireplace to GasSupply on page 19 of this manual.

8. Plug in blower power cord.a.If your fireplace system is installed

as a freestanding unit with an ac-cessory mantel, determine whetherthe power cord will exit the left sideor the right side of the firebox. In-stall one plastic bushing providedinto the 1 1/2" hole in the outer cas-ing through which the power cordwill exit. Install the second plasticbushing provided into the floor sup-port bracket if exiting through theright side (see Figure 33). Routepower cord through (both) plasticbushing(s) and plug the power cordinto a properly grounded 3-prongwall receptacle near the firebox.

b. If your fireplace system installationis recessed and/or pre-wired, aqualified installer must make all elec-trical connections for the outlet kitincluded with the fireplace.

Figure 30 - Mounting Blower to Firebox

TopMountingTab

Exhaust Port

WARNING: A qualified ser-vice person must connect fire-place to gas supply. Follow alllocal codes.

Blower

Figure 31 - Locating Thermal Switch Against Back of Firebox

Thermal Switch

Figure 32 - Attaching Speed Control toFirebox

Figure 33 - Installing Plastic Bushing andWiring Diagram Sticker

Continued

9. Check to make sure that the power cordis completely clear of the blower wheeland that there are no other foreign ob-jects in blower wheel. Turn blower onand check for operation. Turn bloweroff by rotating knob fully counterclock-wise before continuing.

Side View

Firebox Bottom Firebox Back

Firebox Flange

BlowerThermalSwitch

Screws

Lower LouverPanel

Lower RearWall ofFireboxWrapper

ThermalSwitchBracket

ControlKnob

LocknutControl Shaft

SpeedControl

Plastic Bushing

WiringDiagram

Blower SpeedControl Bracket

Page 18: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

18 105455

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)CDV34(N/P)

Figure 35 - Gas Connection* The A.G.A. design-certified manual shutoff valve may be supplied with the applianceor you can purchase it from your retailer.

CAUTION: Use only new,black iron or steel pipe. Inter-nally-tinned copper tubing maybe used in certain areas. Checkyour local codes. Use pipe of 1/2"diameter or greater to allowproper gas volume to fireplace. Ifpipe is too small, undue loss ofpressure will occur.

Installation must include a manual shutoffvalve, union, and plugged 1/8" NPT tap.Locate NPT tap within reach for test gaugehook up. NPT tap must be upstream fromfireplace (see Figure 35).

For propane/LP connections only, the in-staller must supply an external regulator.The external regulator will reduce incominggas pressure. You must reduce incominggas pressure to between 11 and 14 inches ofwater. If you do not reduce incoming gaspressure, heater regulator damage couldoccur. Install external regulator with thevent pointing down as shown in Figure 34.Pointing the vent down protects it fromfreezing rain or sleet.

FIREPLACEINSTALLATIONContinuedINSTALLING GAS PIPING TOFIREPLACE LOCATION

Installation Items Needed

Before installing fireplace, make sure youhave the items listed below.

• external regulator (supplied by installer)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• manual shutoff valve *

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench

• approved flexible gas line with gas con-nector (if allowed by local codes) (notprovided)

* An A.G.A. design-certified manual shutoffvalve with 1/8" NPT tap is an acceptablealternative to test gauge connection. Pur-chase the A.G.A. design-certified manualshutoff valve from your retailer.

WARNING: A qualified ser-vice person must connect fire-place to gas supply. Follow alllocal codes.

CAUTION: For propane/LPunits, never connect heater di-rectly to the propane/LP supply.This heater requires an externalregulator (not supplied). Install theexternal regulator between theheater and propane/LP supply.

CAUTION: Use pipe joint seal-ant that is resistant to liquid pe-troleum (LP) gas.

Figure 34 - External Regulator with VentPointing Down (Propane/LP Only)

Propane/LP SupplyTank

ExternalRegulator

VentPointingDown

Install sediment trap/drip leg in supply lineas shown in Figure 35. Locate sedimenttrap/drip leg where it is within reach forcleaning. Locate sediment trap/drip legwhere trapped matter is not likely to freeze.A sediment trap traps moisture and con-taminants. This keeps them from going intofireplace gas controls. If sediment trap/dripleg is not installed or is installed wrong,fireplace may not run properly.

A.G.A. Design-CertifiedManual Shutoff Valve with1/8" NPT Tap*

3" Minimum

Propane/LP - FromExternal Regulator (11"W.C. to 14" W.C.Pressure)

Approved FlexibleGas Line

Cap Pipe Nipple Tee Joint

Sediment Trap/Drip Leg

Natural - From GasMeter (5" W.C. to 10.5"W.C. Pressure )

Check your building codes for any specialrequirements for locating manual shutoffvalve to fireplaces.

Apply pipe joint sealant lightly to malethreads. This will prevent excess sealantfrom going into pipe. Excess sealant in pipecould result in clogged fireplace valves.

Page 19: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

19105455

OWNER’S MANUAL

Pressure Testing Gas SupplyPiping System

Test Pressures In Excess Of 1/2 PSIG(3.5 kPa)1. Disconnect fireplace and its individual

manual shutoff valve from gas supplypiping system. Pressures in excess of 1/2psig (3.5 kPa) will damage fireplace gasregulator.

2. Cap off open end of gas pipe wheremanual shutoff valve was connected.

3. Pressurize supply piping system by ei-ther opening propane/LP supply tankvalve for propane/LP gas fireplace oropening main gas valve located on or neargas meter for natural gas fireplace, orusing compressed air.

4. Check all joints of gas supply pipingsystem. Apply commercial leak test so-lution to all gas joints. Bubbles formingshow a leak. Correct all leaks at once.

5. Reconnect fireplace and manual shutoffvalve to gas supply. Check reconnectedfittings for leaks.

CHECKING GASCONNECTIONS

WARNING: Test all gas pip-ing and connections for leaksafter installing or servicing. Cor-rect all leaks at once.

WARNING: Never use an openflame to check for a leak. Applycommercial leak test solution toall gas joints. Bubbles formingshow a leak. Correct all leaks atonce.

Installation Items Needed• 5/16" hex socket wrench or nut-driver

• sealant (resistant to propane/LP gas, notprovided)

1. Open lower louver door panel by gen-tly pulling forward.

2. Route flexible gas supply line throughone of the access holes on side of fire-place.

3. Attach flexible gas line from gas sup-ply (see figure 36) to fireplace gasvalve.

4. Check all gas connections for leaks. SeeChecking Gas Connections.

CONNECTING FIREPLACETO GAS SUPPLY

FIREPLACEINSTALLATIONContinued

To Gas Supply(Natural)

To External Regulator(Propane/LP)

Flexible Gas Line fromManual Shutoff ValveProvided by Installer

Figure 36 - Attaching Flexible Gas Line to Control Valve

Continued

Manual Shutoff Valve

Control Valve

Page 20: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

20 105455

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)CDV34(N/P)

FIREPLACEINSTALLATIONContinued

Test Pressures Equal To or Less Than1/2 PSIG (3.5 kPa)1. Close manual shutoff valve (see Fig-

ure 37).

2. Pressurize supply piping system by ei-ther opening propane/LP supply tankvalve for propane/LP gas fireplace oropening main gas valve located on or neargas meter for natural gas fireplace, orusing compressed air.

3. Check all joints from propane/LP sup-ply tank or gas meter to manual shutoffvalve (see Figure 38 for propane/LP orFigure 39 for natural). Apply commer-cial leak test solution to all gas joints.Bubbles forming show a leak. Correctall leaks at once.

Pressure Testing Fireplace GasConnections1. Open manual shutoff valve (see Figure

37).

2. Open propane/LP supply tank valve forpropane/LP fireplace or main gas valvelocated on or near gas meter for natu-ral gas fireplace.

3. Make sure control knob of fireplace isin the OFF position.

4. Check all joints from manual shutoffvalve to thermostat gas valve (see Fig-ure 38 for propane/LP or Figure 39 fornatural). Apply commercial leak test so-lution to all gas joints. Bubbles formingshow a leak. Correct all leaks at once.

5. Light fireplace (see Operating Fire-place, page 24 and 25). Check all otherinternal joints for leaks.

6. Turn off fireplace (see To Turn Off Gasto Appliance, page 24).

Figure 37 - Manual Shutoff Valve

ONPOSITION

OFFPOSITION

Open

Closed

ManualShutoffValve

Figure 39 - Checking Gas Joints for Natural Gas Fireplace

Figure 38 - Checking Gas Joints for Propane/LP Gas Fireplace

Gas Meter

Gas Valve

ManualShutoffValve

Propane/LP Supply Tank

Gas Valve

ManualShutoffValve

Page 21: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

21105455

OWNER’S MANUAL

FIREPLACEINSTALLATIONContinued

Figure 40 - Attaching Battery to Receiver9-Volt Battery

Receiver

TerminalWires

Battery Clip

REMOVING/REPLACINGGLASS DOORYou must remove glass door to install op-tional brick liners, logs, lava rock, and em-ber material.

CAUTION: Do not operate thisfireplace with a broken glass doorpanel. Do not operate this fire-place without the glass door panelsecurely in place. For replace-ment part information see Re-placement Parts , page 30.

Continued

Figure 44- Removing/Replacing Glass Door

Glass DoorAssembly

Screw

Lower Bracket forGlass Door Assembly

INSTALLING OPTIONALWIRELESS HAND-HELDREMOTE CONTROL

Figure 41 - Connecting Remote Accessoriesto Control Valve

To RemoteAccessory

Installing 9-Volt Alkaline Battery inHand-Held Remote Control Unit1. Remove battery cover on back of re-

mote control unit. 2. Attach terminal wires to a 9-volt bat-

tery (not included). Place battery intothe battery housing.

3. Replace battery cover onto remote con-trol unit.

Figure 42 - Installing Battery in Hand-Held Remote Control Unit

BatteryCover

9-VoltBattery

TerminalWires

RemoteControl Unit

BatteryHousing

Figure 43 - Removing Top Louver Panel

Top LouverPanel

1. Remove the upper louver panel by lift-ing upward and out (see Figure 43).

2. Remove the screws from the three tabsat the top of the glass door while hold-ing door securely keeping it from fall-ing forward.

3. Grasp door by both sides and ease itupward off of the lower bracket (seeFigure 44).

4. To replace glass door, follow the aboveinstructions in reverse.

NOTICE: Only use alkaline bat-teries (not included).

Installing 9-Volt Alkaline Batteryinto Receiver1. Open bottom louver and locate the

switch bracket on the left.2. Unscrew the switch bracket. Lean

bracket forward so you are able to ac-cess the back of the remote receiver.

3. Locate the battery clip mounted on theback of the receiver. Slide a 9-volt bat-tery (not included) through the clip.

4. Attach the terminal wires to the battery.5. Connect wire leads to TH and THTP

to control valve (see Figure 41).6. Replace the switch bracket.

Page 22: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

22 105455

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)CDV34(N/P)

INSTALLING OPTIONALBRICK LINER CD8037

WARNING: If fireplace hasbeen running, turn off and un-plug fireplace. Let cool beforeinstalling brick liner.

This brick liner kit is optional. You maypurchase brick liner from your local retaileror see Accessories, page 31.

CAUTION: Always handlebrick panels with two hands. Donot force brick panels into place.Excessive force will break brickpanels.

1. Remove glass door. See Removing/Re-placing Glass Door, pages 21.

2. If installing brick liner in new fireplace,go to step 3. If installing brick liner inan existing fireplace, carefully removelogs, lava rock, and ember material.

3. Install left side brick panel first by slid-ing it between the grate and the side ofthe firebox (see Figure 45).

4. Slide the left retainer bracket againstthe left side brick panel. Loosely se-cure the bracket screw. This secures theleft side brick panel.

5. Install the right brick panel using thesame method described in step 3.

6. Slide the right retainer bracket againstthe right side brick panel. Loosely se-cure the bracket screw. This secures theright side brick panel.

7. Install rear brick panel. Rest bottomedge of panel on back edge of grate (seeFigure 46).

Figure 45 - Installing Left Side Brick Panel

WARNING: The glass doormust be securely in place beforerunning this fireplace. Do not runthis fireplace if glass is missing orbroken.

FIREPLACEINSTALLATIONContinued

Figure 46 - Installing Rear Brick Panel and Retainer Brackets

Left SideBrick Panel

RetainerBrackets

Rear Brick Panel

Retaining Brackets

Attaching Magnetic DecorativeBrass Strips

This fireplace comes with a set of twomagnetic decorative brass strips. Beforeattaching strips to fireplace, remove plasticfilm from brass pieces. After installing thedoor, attach these strips to the top and bot-tom of the glass door frame.

8. Loosely secure retainer brackets to grate.Brackets are adjustable left to right toallow proper placement of panel. Thesewill hold rear panel in place.

9. Tighten all bracket screws.

10. Follow instructions on page 23 to installlogs, lava rock, and ember material.

11. Replace glass door (see page 21).

Page 23: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

23105455

OWNER’S MANUAL

WARNING: The glass doormust be securely in place beforerunning this fireplace. Do not runthis fireplace if glass is missingor broken.

FIREPLACEINSTALLATIONContinued

NOTICE: Do not put lava rock onburner or under burner. Placinglava rock on burner could causeperformance problems.

Each log is marked with a number. Thesenumbers will help you identify the log wheninstalling. It is very important to installthese logs exactly as instructed. Do notmodify logs. Only use logs supplied withfireplace.

1. Remove glass door. See Removing/Re-placing Glass Door, page 21.

2. Place log #1 (back log) on top of grate.Make sure the notches in the bottom ofthe log fit over the grate (see Figure 47).

3. Rest log #2 (large front log) on the pins onthe front part of the grate (see Figure 48).

4. Place log #3 (left piece) onto the frontleft part of the grate. Make sure it isseated properly over the prong of thegrate as shown in Figure 49.

5. Place log #4 (right piece) onto the frontright part of the grate making sure thenotches fit over the prong of the grate(see Figure 50).

6. Place lava rock along sides and frontof inside of firebox bottom. It is notnecessary to use all of the lava rockprovided.

7. Pull ember material apart into piecesno larger than a dime. Place thesepieces loosely and sparingly directlyonto the exposed section of the frontburner and along the space between theburner and grate prongs (see Figure 51).

WARNING: Failure to positionthe parts in accordance with thesediagrams or failure to use onlyparts specifically approved withthis heater may result in propertydamage or personal injury.

INSTALLING LOGS, LAVAROCK AND GLOWINGEMBERS

Ember Material

Figure 51 - Placing Ember Material onBurner

Figure 47 - Installing Log No. 1

Figure 48 - Installing Log No. 2

Figure 49 - Installing Log No. 3

Figure 50 - Installing Log No. 4

This will create the glowing ember ap-pearance as the flame touches the em-ber material. Do not block air slots byusing too much ember material in onearea. It is not necessary to use all of theember material provided.

8. Replace the glass door. See Removing/Replacing Glass Door, page 21.

4

3

2

1

Page 24: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

24 105455

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)CDV34(N/P)

MANUAL LIGHTINGPROCEDURE

OPERATINGFIREPLACE

WARNING: If you do not fol-low these instructions exactly, afire or explosion may result caus-ing property damage, personalinjury or loss of life.

A. This appliance has a pilot which mustbe lighted by hand. When lighting thepilot, follow these instructions exactly.

B. BEFORE LIGHTING smell allaround the appliance area for gas. Besure to smell next to the floor becausesome gas is heavier than air and willsettle on the floor.WHAT TO DO IF YOU SMELL GAS• Do not try to light any appliance.• Do not touch any electric switch; do

not use any phone in your building.• Immediately call your gas supplier

from a neighbor's phone. Followthe gas supplier's instructions.

C. Use only your hand to push in or turnthe gas control knob. Never use tools.If the knob will not push in or turnby hand, don't try to repair it, call aqualified service technician. Force orattempted repair may result in a fireor explosion.

D. Do not use this appliance if any parthas been under water. Immediatelycall a qualified service technician toinspect the appliance and to replaceany part of the control system andany gas control which has been un-der water.

FOR YOUR SAFETYREAD BEFORE

LIGHTING

LIGHTINGINSTRUCTIONS

1. STOP! Read the safety informationin column one.

2. Open lower louver panel.3. Disconnect the wire that runs from

TH to TPTH of valve.4. Turn off all electric power to the

fireplace.5. Push in gas control knob slightly and

turn clockwise to “OFF”.

6. Wait five (5) minutes to clear out anygas. Then smell for gas, includingnear the floor. If you smell gas,STOP! Follow “B” in the safety in-formation in column one. If you don'tsmell gas, go to the next step.

7. The pilot is located by the mainburner and should not require ac-cessing for lighting.

8. Turn knob on gas control counter-clockwise to “PILOT”.

9. Push in control knob all the way andhold. Immediately light the pilot byrepeatedly depressing the piezospark ignitor until a flame appears.Continue to hold for about one (1)minute after the pilot is lit. Releaseknob and it will pop back. Pilotshould remain lit. If it goes out, re-peat steps 5 through 8.• If knob does not pop up when

released, stop and immediately callyour service technician or gassupplier.

• If the pilot will not stay lit after sev-eral tries, turn the gas control knobto “OFF” and call your servicetechnician or gas supplier.

10. Reconnect the wire to TH and TPTHto the valve.

11. Turn on all electric power to thefireplace.

TO TURN OFF GASTO APPLIANCE

1. Open lower louver panel.2a. Disconnect wire from TH and TPTH

on valve.2b. If Using optional ON/OFF Switch:

Turn ON/OFF switch off.2c. If Using optional Hand-Held Re-

mote: Set selector switch in the OFFposition to prevent draining battery.

3. Turn off all electrical power to theappliance if service is to be performed.

4. Push in gas control knob slightly andturn clockwise to “OFF”.

5. Close lower louver panel.

Shutting Off Burners Only (pilotstays lit)

You may shut off the burners and keepthe pilot lit by doing one of the following:1. Turn control knob clockwise

to the PILOT position.2. Set selector switch in the OFF position.

OFF

PILOT ON

L O

IH

Figure 52 - Control Valve

PiezoIgnitor

Gas Control Knob Variable Control Knob

12. Turn gas control counterclockwise to “ON”.

13. This valve is equipped with a HI/LOfeature. Set fireplace input as desired.

14. Close lower louver panel.

1. Remove glass door (see Removing/Replacing Glass Door, page 21).

2. Follow steps 1 through 8 under Light-ing Instructions.

3. Depress control knob and light pilotwith match.

4. Keep control knob pressed in for 30seconds after lighting pilot. After 30seconds, release control knob. Followsteps 10 through 14 under LightingInstructions.

5. Replace glass door (see Removing/Replacing Glass Door, page 21).

Page 25: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

25105455

OWNER’S MANUAL

OPERATINGFIREPLACEContinued

OPERATINGOPTIONAL BLOWER

ACCESSORYLocate the blower controls by openingthe lower louver panel on the fireplace.Blower controls are located on the leftside of the switch bracket to the left justinside the louver panel.

Both the GA3750 manual blower and theCDA3620T thermostatically-controlledblower have an ON setting and an OFFsetting. The blower will only run when theswitch is in the ON position. In the OFFposition, the blower will not operate.

The blower helps distribute heated airfrom the fireplace. Periodically check thelouvers of the firebox and remove anydust, dirt, or other obstructions that willhinder the flow of air.

INSPECTINGBURNERSCheck pilot flame pattern and burner flamepatterns often.

PILOT ASSEMBLYThe pilot assembly is factory preset for theproper flame height. Alterations may haveoccurred during shipping and handling. Calla qualified service person to readjust thepilot if necessary.

The height of the thermopile must be 3/8" to1/2" above the pilot flame as shown in Figure54. The thermocouple must be at a height ofabout 1/8" above the pilot flame. The flamefrom the pilot burner must extend beyondboth the thermocouple and thermopile.

If your pilot assembly does not meet theserequirements:

• turn fireplace off (see To Turn Off Gas toAppliance, page 24)

• see Troubleshooting, pages 27 through 29

Figure 54 - Pilot Assembly

Thermocouple

Thermopile

3/8" to 1/2"

1/8"

Pilot Burner

PiezoIgnitor

BURNER FLAME PATTERNBurner flames will be steady; not lifting orfloating. Flame patterns will be differentfrom unit to unit and will vary depending oninstallation type and weather conditions.

If the vent configuration is installed incor-rectly, the flames will lift or "ghost". Thiscan be dangerous. Inspect the flames afterinstallation to ensure proper installation andperformance.

Figure 55 shows a typical flame pattern forCDV34(N/P)(A).

If burner flame pattern differs from thatdescribed:

• turn fireplace off (see To Turn Off Gas toAppliance, page 24)

• see Troubleshooting, pages 27 through 29

Figure 55 - Typical Flame Pattern forCDV34(N/P)(A).

OFFPILOT

ON

LO IH

ONOFF

REMOTE OFF ON

Figure 53 - Setting for Remote Operation

Remote Control Knob inRemote Position

Control Knobin On Position

FlameAdjustmentKnob

Blower Control Knob(Optional Accessory)

HAND-HELD REMOTEOPERATION

1. After lighting, let pilot flame burn forabout one minute. Turn control knobon the control valve to ON position.Turn flame adjustment knob any-where between HI and LO. Turn theknob to the REMOTE setting. Note:The burners may light if hand-heldselector switch was last turned off. Youcan now turn the burners on and offwith the hand-held remote control unit.IMPORTANT: Do not leave the se-lector switch in the REMOTE posi-tion when the pilot is not lit. This willdrain the battery.

2. Press the ON/OFF button to turn theburners on and off. When turningburners off, the pilot will remain lit.IMPORTANT: To turn the pilot off,manually turn the control knob on theheater to the OFF position.

NOTICE: You must light the pilotbefore using the hand-held re-mote control unit. See LightingInstructions , page 24.

Page 26: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

26 105455

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)CDV34(N/P)

PILOT AND BURNERS• Remove ember material before cleaning

burners and replace when cleaning iscomplete.

• Burner and controls should be cleanedwith compressed air to remove dust, dirt,or lint.

• Use a vacuum cleaner or small, softbristled brush to remove excess dust, dirt,or lint.

WARNING: Only parts sup-plied by the manufacturer shouldbe used when replacing brokenor damaged glass door panel (seeReplacement Parts , page 30). Thisglass door panel is a completeunit. No substitute materials maybe used.

CLEANING ANDMAINTENANCE

If glass has been broken, carefully removeglass door (see Removing/Replacing GlassDoor, page 21). Vacuum all glass pieces witha shop vac.

CAUTION: Wear gloves andsafety glasses while handling orremoving broken glass. Do notremove if glass is hot. Keep chil-dren and pets away from glass.

WARNING: Do not operatefireplace with the glass door re-moved, cracked, or broken.

VENTING SYSTEMConduct annual inspection of the ventingsystem following these guidelines:

1. Check areas of venting system that areexposed to the weather for corrosion (rustspots or streaks and, in extreme cases,holes). Have these items replaced imme-diately by a qualified service person.

2. Remove the vent cap and shine a flash-light into the vent. Remove any foreignmaterial.

3. Check for evidence of excessive con-densation. Continuous condensationcan cause corrosion of caps, pipes, andfittings and can be caused by havingexcessive lateral runs, too many elbows,or exterior portions of the system be-ing exposed to cold weather.

4. Inspect joints to verify that no pipe sec-tion or fitting has been disturbed andloosened. Check mechanical supportssuch as wall straps for rigidity.

WARNING: Turn off fireplaceand let cool before cleaning.

CAUTION: You must keep con-trol areas, burners, and circulat-ing air passageways of fireplaceclean. Inspect these areas of fire-place before each use. Have fire-place inspected yearly by a quali-fied service person. Fireplace mayneed more frequent cleaning dueto excessive lint from carpeting,bedding material, pet hair, etc.

WARNING: Do not use abra-sive cleaners as this may damageglass. Use a nonabrasive house-hold glass cleaner to clean glass.Do not clean glass when hot.

WARNING: Handle glass doorpanel with care. Do not strike,slam or otherwise abuse glass.Do not operate fireplace with theglass door removed, cracked, orbroken.

GLASS DOOR

Glass must be cleaned periodically. Duringstart-up it is normal for condensation toform on the inside of the glass causing lint,dust, and other airborne particles to cling tothe glass surface. During initial start-up aslight film may form on the glass due topaint curing. The glass should be cleanedseveral times with a non-ammonia, non-abrasive household cleaner and warm waterafter the first two weeks of operation. There-after, clean the glass two or three timesduring each heating season, depending onthe usage and circumstances present. Referto Removing/Replacing Glass Door on page21 of this manual when removing glass doorfor cleaning.

LOGS• If you remove logs for cleaning, refer to

Installing Logs, Lava Rock, and GlowingEmbers, page 23, to properly replace logs.

• Use a vacuum cleaner to remove any car-bon buildup on logs.

• Replace log(s) if broken. See Replace-ment Parts on page 30.

• Replace ember material periodically asneeded. See Replacement Parts on page 30.

CAUTION: Do not vacuum ifpieces are hot.

Use only the glass door replacement in-tended for this fireplace (see ReplacementParts, page 30 for detail on ordering). Nosubstitutions may be made. See Removing/Replacing Glass Door, page 21 for instruc-tions for replacing glass door.

Page 27: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

27105455

OWNER’S MANUAL

TROUBLESHOOTING WARNING: Turn off heaterand let cool before servicing. Onlya qualified service person shouldservice and repair heater.

CAUTION: Never use a wire,needle, or similar object to cleanpilot. This can damage pilot unit.

POSSIBLE CAUSE

1. Ignitor electrode not connected to igni-tor cable

2. Ignitor cable pinched or wet

3. Piezo ignitor nut is loose

4. Broken ignitor cable5. Bad piezo ignitor6. Ignitor electrode broken7. Ignitor electrode positioned wrong

1. Gas supply turned off or manual shutoffvalve closed

2. Control knob not in PILOT position3. Control knob not pressed in while in

PILOT position4. Air in gas lines when installed

5. Depleted gas supply (propane/LP modelsonly)

6. Pilot is clogged

7. Gas regulator setting is not correct

1. Control knob not fully pressed in2. Control knob not pressed in long enough

3. Manual shutoff valve not fully open4. Pilot flame not touching thermocouple,

which allows thermocouple to cool,causing pilot flame to go out. This prob-lem could be caused by one or both ofthe following:A) Low gas pressureB) Dirty or partially clogged pilot

5. Thermocouple connection loose at con-trol valve

6. Thermocouple damaged7. Control valve damaged

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if pinched by anymetal or tubing. Keep ignitor cable dry

3. Tighten nut holding piezo ignitor. Nutis located behind the mounting bracket

4. Replace ignitor cable5. Replace piezo ignitor6. Replace pilot assembly7. Replace pilot assembly

1. Turn on gas supply or open manualshutoff valve

2. Turn control knob to PILOT position3. Press in control knob while in PILOT

position4. Continue holding down control knob.

Repeat igniting operation until air is re-moved

5. Contact local propane/LP gas company

6. Clean pilot (see Cleaning and Maintenance,page 26) or replace pilot assembly

7. Replace gas control

1. Press in control knob fully2. After pilot lights, keep control knob

pressed in 30 seconds3. Fully open manual shutoff valve4. A) Contact local gas company

B) Clean pilot (see Cleaning andMaintenance, page 26) or replace pilotassembly

5. Hand tighten until snug, then tighten1/4 turn more

6. Replace thermocouple7. Replace control valve

OBSERVED PROBLEM

When ignitor button is pressed, there is nospark at pilot

When ignitor button is pressed, there isspark at pilot but no ignition

Pilot lights but flame goes out when controlknob is released

Note: For additional help, visit DESAInternational’s Technical Service website at www.desatech.com .

Note: All troubleshooting items are listed inorder of operation.

www.desatech.com Continued

Page 28: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

28 105455

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)CDV34(N/P)

OBSERVED PROBLEM

Burner does not light after pilot is lit

Delayed ignition burner

Burner backfiring during combustion

Slight smoke or odor during initial operation

Heater produces a whistling noise whenburner is lit

Glass soots

Fireplace produces a clicking/ticking noisejust after burners are lit or shut off

Remote does not function

REMEDY

1. Clean burner (see Cleaning and Mainte-nance, page 26) or replace burner orifice

2. Contact local propane/LP or natural gascompany

3. Reconnect leads (see Wiring Diagram,page 30)

4. Replace thermopile

1. Contact local propane/LP or natural gascompany

2. Clean burner (see Cleaning and Main-tenance, page 26) or replace burner orifice

1. Clean burner (see Cleaning andMaintenance, page 26) or replace burnerorifice

2. Replace damaged burner3. Replace gas control

1. Problem will stop after a few hours ofoperation

1. Turn control knob to LO position andlet warm up for a minute

2. Operate burner until air is removed fromline. Have gas line checked by local pro-pane/LP gas company

3. Clean burner (see Cleaning and Mainte-nance, page 26) or replace burner orifice

1. Adjust the log set so that the flame doesnot excessively impinge on it

2. Inspect the opening at the base of theburner to see that it is NOT packed withany type of material

1. This is common. If noise is excessive,contact qualified service person

1. Replace 9-volt alkaline battery in receiverand remote control

TROUBLESHOOTINGContinued

POSSIBLE CAUSE

1. Burner orifice clogged

2. Inlet gas pressure is too low

3. Thermopile leads disconnected or im-properly connected

4. Thermopile is defective

1. Manifold pressure is too low

2. Burner porting or orifice clogged

1. Burner orifice is clogged or damaged

2. Damaged burner3. Gas regulator defective

1. Residues from manufacturing processesand logs curing

1. Turning control knob to HI positionwhen burner is cold

2. Air in gas line

3. Dirty or partially clogged burner orifice

1. Flame impingement on logs

2. Debris around burner air mixer

1. Metal expanding while heating or con-tracting while cooling

1. Battery is not installed Battery power is low

www.desatech.com

Page 29: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

29105455

OWNER’S MANUAL

TROUBLESHOOTINGContinued

WARNING: If you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not touch any electrical switch; do not use any phone in your building.• Immediately call your gas supplier from a neighbor’s phone. Follow the gas

supplier’s instructions.• If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies,paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. Thesefumes may mix with combustion air and create odors. These odors will disappear over time.

POSSIBLE CAUSE

1. Gas leak. See Warning statementabove

1. High or gusting winds

2. Low line pressure

3. Pilot is partially clogged

4. Inner vent pipe leaking exhaust gassesinto system

5. Horizontal vent improperly pitched

6. Glass too loose and air tight gasket leaksin corners after usage

7. Bad thermopile or thermocouple8. Improper vent cap installation

1. Gas leak. See Warning statementabove

2. Control valve defective

1. Gas leak. See Warning statementabove

1. Improper log placement

2. Air holes at burner inlet blocked

3. Burner flame holes blocked

OBSERVED PROBLEM

Fireplace produces unwanted odors

Fireplace shuts off in use

Gas odor even when control knob is in OFFposition

Gas odor during combustion

Dark residue on logs or inside of fireplace

REMEDY

1. Locate and correct all leaks (see Check-ing Gas Connections, pages 19 and 20)

1. Fireplace has been tested for up to40mph winds. However, extreme con-ditions may occur. See Lighting Instruc-tions on page 24

2. Contact local propane/LP or natural gascompany

3. Clean pilot (see Cleaning and Mainte-nance, page 26)

4. Locate and correct all leaks (see Check-ing Gas Connections, pages 19 and 20)

5. Horizontal vent termination should slopedown only enough to prevent any waterfrom entering the unit. The maximumdownward slope of the vent terminationis 1/4" for any horizontal run

6. Tighten glass

7. Replace faulty component8. Check for proper installation and free-

dom from debris or blockage

1. Locate and correct all leaks (see Check-ing Gas Connections, page 19 and 20)

2. Replace control valve

1. Locate and correct all leaks (see Check-ing Gas Connections, pages 19 and 20)

1. Properly locate logs (see Installing Logs,Lava Rock, and Glowing Embers, page 23)

2. Clean out air holes at burner inlets. Pe-riodically repeat as needed

3. Remove blockage or replace burner

www.desatech.com

Page 30: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

30 105455

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)CDV34(N/P)

SERVICE HINTSWhen Gas Pressure Is Too Low• pilot will not stay lit• burners will have delayed ignition• fireplace will not produce specified heat• propane/LP gas supply might be low

(propane/LP units only)

When Gas Quality Is Bad• pilot will not stay lit• burners will produce flames and soot• fireplace will backfire when lit

If you feel your gas pressure is too low or gasquality is bad, contact your local natural orpropane/LP gas supplier.

TECHNICALSERVICEYou may have further questions about in-stallation, operation, or troubleshooting. Ifso, contact DESA International’s TechnicalService Department at 1-800-DESA LOG(1-800-337-2564).

You can also visit DESA International’sTechnical Service web site atwww.desatech.com.

REPLACEMENTPARTS

Figure 56 - Blower Wiring Diagram for Thermostat-Controlled Models

WIRING DIAGRAM

CAUTION: Label all wires prior to disconnection when servicingcontrols. Wiring errors can cause improper and dangerous operation.Verify proper operation after servicing.

Red

VariableFan Switch Fan Switch

(N.O.)

Black

Black

GreenWhite

On

110/115 V.A.C.

BlowerMotor

Black

Off1

2 Red

Note: Use only original replacement parts.This will protect your warranty coverage forparts replaced under warranty.

PARTS UNDER WARRANTYContact authorized retailers of this product.If they can not supply original replacementpart(s), call DESA International’s Techni-cal Service Department at 1-800-DESALOG (1-800-337-2564).

When calling DESA International, have ready• your name• your address• model and serial numbers of your fire-

place• how fireplace was malfunctioning• type of gas used (propane/LP or natural

gas)• purchase date

Usually, we will ask you to return the defec-tive part to the factory.

PARTS NOT UNDERWARRANTYContact authorized retailers of this product.If they can not supply original replacementpart(s), call DESA International’s PartsDepartment at 1-800-972-7879 for referralinformation.

When calling DESA International, have ready• model number of your fireplace• the replacement part number SPECIFICATIONS

CDV34N(A) CDV34P(A)

Btu 16,000/22,000 Btu/h 16,000/20,000 Btu/h

Gas Type Natural Propane/LP

Ignition Piezo Piezo

Manifold Pressure 3.5" w.c. 10.0" w.c.

Minimum Inlet Supply Pressure 4.5" w.c. 11.0" w.c.

Dimension, Inches/mm (HxWxD)Fireplace 33" x 34" x 18 1/2" 33" x 34" x 18 1/2"

838 x 864 x 470mm 838 x 864 x 470mm

Carton 37" x 40" x 21" 37" x 40" x 21"940 x 1016 x 533mm 940 x 1016 x 533mm

Weight, lbs/kgFireplace 132 lbs/60 kg 132 lbs/60 kgShipping 135 lbs/61 kg 135 lbs/61 kg

Page 31: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

31105455

OWNER’S MANUAL

ACCESSORIES

CABINET MANTELACCESSORY WITHFIREPLACE PERIMETERBRASS TRIMGMC11F Series - Walnut FinishedHardwood Veneer

GMC12U Series - Unfinished Hard-wood Veneer

GMC13F Series - Medium Stained OakVeneer

Mantel features moldings, fluted sides, andmedallion. Available in walnut finished orunfinished hardwood, ready to stain or paint.Shown with optional base accessory.

Dimensions (H x W x D): 48" x 563/4" x 223/4"

HEARTH BASEGC3333F Series - Walnut FinishedHardwood Veneer

GC3334U Series - Unfinished Hard-wood Veneer

GC3335F Series - Medium StainedOak Veneer

The hearth base creates a handsome riser forthe fireplace .

Dimensions (H xW xD): 6 1/2" x 58" x 28 9/16"

Purchase these fireplace accessories fromyour local retailer. If they can not supplythese accessories, call DESA International’sSales Department at 1-800-432-2382. forinformation. You can also write to the ad-dress listed on the back page of this manual.

MANUAL BLOWER KITGA3750Manual variable control blower accessory pro-vides better heat distribution. Complete in-stallation and operation instructions includedin this manual.

THERMOSTATICALLY-CONTROLLED BLOWER KITCDA3620TProvides better heat distribution. Blowerturns off and on automatically, as needed.Complete installation and operation instruc-tions included in this manual.

DUPLEX OUTLET KITGA3555(Not Shown)

Use for built-in installations when hard wir-ing a blower.

FIREPLACE SCREENCDS34For all models. This fireplace screen easilyattaches to the front glass panel with in-cluded clips.

RECEIVER AND HAND-HELDREMOTE CONTROL KITCGHRC SERIESFor all models. Allows the heater to beturned on and off conveniently.

BRASS TRIM ACCESSORYGA7090(Not Shown)

Optional with built-in installation. Provides afinished appearance covering rough and/orunfinished mantel or wall opening, edges, etc.

BRICK LINER - CD8037(Not Shown)

This brick liner adds a touch of style to yourdirect-vent fireplace. Complete installationand operation instructions included in thismanual.

FLEXIBLE GAS LINECONNECTOR - GA5081(Not Shown)

For all models.

TWO PIECE BRASS ACCENTTRIM - CD7034(Not Shown)

For all models. Add a touch of class to yourfireplace.

CORNER MANTELACCESSORY(Not Shown)GMC36F Series - WalnutFinished Hardwood VeneerGMC37U Series - UnfinishedHardwood Veneer

Mantel features moldings, fluted sides, andmedallion. Available in walnut finished orunfinished hardwood, ready to stain or paint.

Dimensions (H x W x D): 48 3/4" x 60 7/8" x34 3/4"

Page 32: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

32 105455

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)CDV34(N/P)

1

2

3

4

6

6

35

5

5

5

11 (Included inHardware Pack)

7

7

8

10

9

12

13

1415

16

17

18

19

20

32

2122

23

24

252627

28

28

29

30

31-1

31-4

31-2

31-3

33

32

32

34

46

36

37

39

38

42

40

41

6

44

43

45

ILLUSTRATEDPARTSBREAKDOWNCDV34(N/P)(A)

Page 33: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

33105455

OWNER’S MANUAL

27 104507-01 Brass Elbow 128 104508-01 Brass Fitting 229 104509-01 Aluminum Tubing Assy 130 104510-01 Pilot Tubing Assembly 131 105457-01 Log Set 131-1 105772-01 Rear Log 131-2 105772-02 Front Log 131-3 105772-03 Left Piece 131-4 105772-04 Right Piece 132 M10908-02 Screw 633 M12461-73 Screw 334 H5C4-20B Bolt 235 M12461-26 Screw 436 104555-02CJ Grate Assembly 137 104940-11 Glass Door Assembly 138 104615-02 Insulation 139 105450-01 Front Assembly 140 104313-01 Hinge, Pin-Left 141 104313-02 Hinge, Pin-Right 142 104954-01 Screw 143 104963-01 Washer 344 104955-01 Nut 345 105575-01 Wire Harness 346 NTC-4C Lock Nut 1

PARTS LISTDIRECT-VENT FIREPLACECDV34(N/P)(A)

This list contains replaceable parts used in your fireplace. When ordering parts, follow theinstructions listed under Replacement Parts on page 30 of this manual.

KEYNO. PART NUMBER DESCRIPTION QTY.

1 104445-01 Top Outer Casing-34" 12 105278-01 Outer Casing-34" 13 105297-01 Bottom Outer Casing 14 104479-10BR Firebox Assembly 15 M11084-26 Screw, Hex 506 M11084-46 Screw, Hex 87 105394-01 Louver, Extruded 28 104443-01 Firebox Support, Right 19 104486-01 Firebox Support, Left 110 104482-01 Switch Bracket 111 104483-01 Floor Mounting Bracket 212 104491-01 Relief Cover 113 104518-01 Relief Cover Gasket 114 104527-01 Relief Springs 215 104528-01 Relief Washer 216 104537-01 Valve Bracket 117 104496-01 Sit Valve, Natural 1

104496-02 Sit Valve, Propane/LP18 104497-01 Sit Pilot, Natural 1

104497-02 Sit Pilot, Propane/LP19 104498-01 Thermocouple 120 104499-01 Thermopile 121 104500-01 Piezo Ignitor 122 104501-01 Ignitor Bracket 123 104502-01 Ignitor Screw 124 104503-01 Ignitor Wire 125 104504-01 Burner, Natural 1

104504-02 Burner, Propane/LP26 104506-01 Orifice, Natural 1

104506-02 Orifice, Propane/LP

KEYNO. PART NUMBER DESCRIPTION QTY.

PARTS INCLUDED - NOT SHOWN

GA6060 Lava Rock104529-01 Ember Material

Page 34: DIRECT-VENT FIREPLACE...1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified

LIMITED WARRANTYDIRECT-VENT FIREPLACE

DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of firstpurchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heaterto proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUSTbe obtained through authorized retailers of this product and/or DESA International who will provide original factory replacement parts.Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordancewith all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or becomedamaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost,labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT;THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA-TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESSFOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE;AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT ANDDESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT,INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequentialdamages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004

www.desatech.com

INTERNATIONAL

KEEP THIS WARRANTY

WARRANTY INFORMATION

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard writtenwarranty. We make no other warranty, expressed or implied.

105455-0155763Rev. A05/99NOT A UPC

105455 01