Direct Electric Heating Of Domestic Water

14
-SAMARTH PAWAR DR. TADUESZ CZASZEJKO DIRECT ELECTRIC HEATING OF DOMESTIC WATER

description

Final Year Project Presentation

Transcript of Direct Electric Heating Of Domestic Water

Page 1: Direct Electric Heating Of Domestic Water

-SAMARTH PAWARDR. TADUESZ CZASZEJKO

DIRECT ELECTRIC HEATING OF DOMESTIC WATER

Page 2: Direct Electric Heating Of Domestic Water

INTRODUCTIONAIM

Heat Water by passing electric current directly through it.

Limit CurrentPrevent Electrolysis of Water

Page 3: Direct Electric Heating Of Domestic Water

INTRODUCTION

POWER SUPPLY UNITAC source / Rectified DC

sourceCONTROLLER UNIT

HEATThermocouple

CURRENTHall Effect sensor

ELECTRODESParallel plateR=ρ*length/surface area

POWER SUPPLY

CONTROLLER

COLD

HOT

Page 4: Direct Electric Heating Of Domestic Water

POWER SUPPLY

Low Peak to RMS ratio.Firing Angle control of thyristor.H-Bridge switching , emulating alternating

current.Low losses.

Page 5: Direct Electric Heating Of Domestic Water

CONTROLLER SOLUTIONCONTROL PARAMETERS

Reference Current(Ir)Reference Temperature(Tr)

WATER MODEL PARAMETERSLength, Width (gap between electrodes), Height,

Resistance, Flow Rate and Initial Temperature.

Tr PI(t) PI(i)PLANT1: POWER SUPPLY

PLANT2: ELECTRODES

-1

-1

Et Ir Ei α I T

Page 6: Direct Electric Heating Of Domestic Water
Page 7: Direct Electric Heating Of Domestic Water

PSIM SIMULATIONS – (flow rate)

FLOW RATE = 9L/m, R=5 Ohms, Initial Temperature = 0 FLOW RATE = 7.8L/m, R=5 Ohms, Initial Temperature = 0

FLOW RATE = 6.6L/m, R=5 Ohms, Initial Temperature = 0 FLOW RATE = 0.5L/m, R=5 Ohms, Initial Temperature = 0

Page 8: Direct Electric Heating Of Domestic Water

PSIM SIMULATIONSFLOW RATE = 9L/m, R=4 Ohms, Initial Temperature = 0 FLOW RATE = 9L/m, R=1 Ohms, Initial Temperature = 0

FLOW RATE = 9L/m, R=5 Ohms, Initial Temperature = 10 FLOW RATE = 9L/m, R=5 Ohms, Initial Temperature = 20

Page 9: Direct Electric Heating Of Domestic Water

EXPERIMENTAL SET UP

Isolation Step Down TransformerDiode BridgeCapacitor-470uFResistor-112 Ohms Load bank setting.Dead time control

Page 10: Direct Electric Heating Of Domestic Water

MINIMUM DEAD TIME OF 4US CLOSER TO MAXIMUM DEAD TIME

MINIMUM DEAD TIME , SHOWS RECTIFIED VOLTAGE SWITCHING VOLTAGES ACROSS THE ELECTRODES

Page 11: Direct Electric Heating Of Domestic Water

CONCLUSIONSUniversal water heater – higher supply

voltages, support wide range of resistivity’s.

Page 12: Direct Electric Heating Of Domestic Water

CONCLUSIONSUse of Simulation Model

Better ElectrodesDifferent components

Alternate MethodsBuck/Boost Convertor topologiesDevelopment of better inductors

Experimental Set Up can be used with electrodes with isolation.

Page 13: Direct Electric Heating Of Domestic Water

ACKNOWLEDGMENTDr. Tadeusz CzaszejkoMr. Ian Reynolds, Mr Ray Chapman and Mr

Ray CooperSpecial thanks to David PetzerThank You Supervisors

Page 14: Direct Electric Heating Of Domestic Water