DDP Sharing MY JOURNEY. Overview DDP StructureMy Journey Pros & Cons.
Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf ·...
Transcript of Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf ·...
![Page 1: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/1.jpg)
© 2014 Fluor. All Rights Reserved.
Dimensional Data for Piping(DDP)
By L. Webster
![Page 2: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/2.jpg)
Special Thanks
♦ The Fisher FIRST & DDP work process slides are original from a presentation prepared by:– John Dressel, Fluor– Keith Herbsleb, Emerson (Puffer Sweiven)– Janelle Prusha, Emerson
2
![Page 3: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/3.jpg)
Overview
♦ The Basics– Setup– DDP Groups– Working Data Browser
♦ Next Evolution– SP3D Groups– Re-use Data - Default Data Browser
♦ Hexagon/Fisher (Fisher FIRST 2.0)– Optimizing Valve Sizing Work Processes
3
![Page 4: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/4.jpg)
Setup
♦ Domain Administrator– Click Add-Ins > Import DDP
Library Data > From SmartPlant 3D
– Connect– Import
♦ Imports– DDP Groups– Piping End Connection Types– Piping Classes
4
![Page 5: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/5.jpg)
5
Original DDP Groups
♦ Approx. 100 Different Groups♦ Original DDP Groups didn’t have
values for rotation– Change groups to change rotation
♦ Lose dimensional data when groups are changed
![Page 6: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/6.jpg)
Enter Data
♦ Dimensional Data Sheet– Tag by Tag
6
![Page 7: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/7.jpg)
Enter Data - Working Data Browser
♦ Multiple Tags♦ Set the status - Preliminary / Design / Certified
7
![Page 8: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/8.jpg)
8
♦ The DDP data is Published to SmartPlant Foundation (SPF) for S3D to Retrieve into the 3D Model with Tag Numbers
Publish
![Page 9: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/9.jpg)
♦ The Piping Designer selects the Valve Tag and places the Fully Dimensioned Valve into the Model
♦ The Instrument Designer Checks the Instrument Connection, Maintenance Access and Orientation of the Valve
Valve isPlaced
The TagIs Select
Retrieve & Place in S3D
![Page 10: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/10.jpg)
10
Next Evolution
♦ 10 New S3D Groups cover 90% of the of the PDS groups
♦ S3D Groups with rotation♦ PDS groups still available for
S3D as well
![Page 11: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/11.jpg)
Re-Use Data - Default Data Browser
♦ Fluor has created a Global SPI DDP Database for loading Default Data– Uploaded with Mfr & Model dimensions from previously purchased instruments– Copy data from Default Browser to Working Data for matching Mfr, Model and
size
11
![Page 12: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/12.jpg)
12
♦ Fisher FIRST 2.0 Transfer control valve spec sheets and envelope dimensions as DATA rather than graphic PDF files
How can DDP be easier, faster, and more reliably?
Process Conditions Specification Sheet Sizing Calculations Piping 3D Model
![Page 13: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/13.jpg)
The FF to SPI Manual Work Process
Export Valve Spec Sheet
from SPI
Input Selection data
into SPI
Input SPI Spec Data
into FF
Retrieve DDP datainto S3D
EPC I&CEngineer
(SPI)
Fisher Sales Office - Puffer-Sweiven
(FF)
EPC Piping and InstrumentDesigners
(S3D)
Complete SPIControl Valve Spec Sheet
Spec Sheet with Process
Data
Valve Spec Sheet Selection
Data
Create SPI Valve Spec Sheet with
Process Data andDefine DDP Group
Export ModelNumber and
Certified Data
Publish DDP data to SPF
Size and Select Control Valve with FF
Associate Tag to DDP Group
Valve CertifiedDimensional Data Sheet
Input Certified
Dimensional Data into
S3D
Input Preliminary DDP Dimensional Data
Manual Data Input
IssueValve
Purchase Order
Control valve shape placed into Piping Design Model
SmartPlant Foundation
(SPF)
Update Control valve shape from Design Basis
![Page 14: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/14.jpg)
Fisher Valve Sizing and Selection
14
♦ Fisher FIRST - Valve Sizing and Selection and Pricing software made Fisher a pioneer in Valve sizing automation
♦ Fisher FirstVue - an extension of Fisher FIRST was used by EPCs for Sizing calculations and Selection of Valves
♦ Fisher Specification Manager (FSM) gave Fisher FirstVue an interface into SPI with DDP information for use by EPCs
♦ Fisher FIRST 2.0 merged the functionality of Fisher FIRST for Valve Sizing and Selection and Pricing with the Specification Manager’s interface to SPI and DDP data
![Page 15: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/15.jpg)
15
The FF2 to SPI Interface Work Process
Export Valve Spec Sheet
from SPI
Import into SPI with FF2 link File
Import SPI Data into
FF2
Retrieve Tagand DDP data
design into S3D
EPC I&CEngineer
(SPI)
Fisher Sales Office - Puffer-Sweiven
(FF2)
EPCPiping
Designer
(S3D)
Complete Control Valve Spec Sheet
CSV file withvalve and
process data
CSV file withValve Spec
Sheet and DDP Data
Create SPI Valve Spec Sheet with
Process Data
Export Spec & Link File for FF2
and DDP Data
Publish Tag and DDP data to SPF
Size and Select Control Valve in FF2
Control valve shape placed
into Piping Design Model
IssueValve
Purchase Order
SmartPlant Foundation
(SPF)
Associate Tag to DDP Group
Input Preliminary DDP Dimensional Data
![Page 16: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/16.jpg)
SPI SPEC FORM 90
16
Fisher worked with Intergraph to create SPI Form 90, the standard
control valve spec sheet for Fisher products
![Page 17: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/17.jpg)
Form 90 or Custom Form
17
♦ Typically companies have custom forms in SPI♦ The new FF2 link mapping process can handle either…
– SPI Form 90 Standard Fisher control valve specification sheet– Custom valve spec sheet form in SPI with mapped link file
or
PI)
FisherFIRST 2
StandardFF2-to-SPIData File
SPI Import Module
Fisher importmap ‘Link File’
custom import map ‘Link File’
Form 90 -Fisher Spec Sheet Form
Custom valve Spec Sheet Form
or
![Page 18: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/18.jpg)
18
FF2 Spec and DDP Functions
♦ The .CSV data file includes both the Control Valve Spec Sheet and DDP data
♦ Import link file is provided for SPI Import Module ♦ The SPI user has the option to import all the Spec Data or Just the
Size, Cv and Catalog numbers as needed
Approx. 400 columns of Control Valve Spec Sheet data
Approx. 40 columns of associated Dimensional Data for Piping (DDP)
![Page 19: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/19.jpg)
Fisher Spec Sheet Data …
AND
Dimensions Data for Piping
Before importing Fisher Spec Data and DDP data into SPI the user can do a comparison to see what data fields had changed
SPI Imports FF2 Spec Data and DDP Data using link files
FF2 Import
![Page 20: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/20.jpg)
20
Many new “Standard” shapes have been defined in SPI and S3D specifically for Fisher control valves
FF2 DDP Groups
![Page 21: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/21.jpg)
21
Dimensional Data for Piping
Example of Intergraph 3D shape used for Fisher
DDP
♦ In S3D the new DDP Shapes closely resemble the actual Fisher Valves
Control Valve Photo
![Page 22: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/22.jpg)
22
Future Enhancements
♦ HEXAGONPPM Intergraph recently announced the development of Vendor Application Programming Interfaces (APIs)
♦ Future releases of Fisher FIRST 2.0 will be able to Read and Write data directly from and to SmartPlant Instrumentation
♦ The APIs will eliminate the use of .CSV files to Export and Import Data
♦ Data will be Published and Retrieved through the APIs and have Management of Change and Data Validation
SPI
FF2
API
![Page 23: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor](https://reader031.fdocuments.us/reader031/viewer/2022022505/5abb34e87f8b9a441d8c8d0d/html5/thumbnails/23.jpg)
Questions
23