LF UM33A-01EN-S6
Digital Indicator with Alarms
Modbus RTU Master/Data Monitor FunctionUM33A/S006
Monitor the data you wantAdd instruments easily
NEW
Food factory
Monitor freezing and cooling temperature and humidity
PC
Check site conditions while monitoring temperature and humidity of the production line and storehouse.
Monitor wastewater treatment
PC
UM33A
Concentration sensor
Concentration sensor
Wastewater treatment
Wastewater treatment
RS-485
Monitor concentrations of wastewater and easily detect abnormalities on site, reducing on-site labor.
Wastewater treatment facility
Modbus data monitor
On-site and remote monitoring of tank levelsAchieve remote monitoring of conditions inside multiple tanks, while lowering on-site monitoring costs.
Supports facilities expansionUse it for site monitoring as you expand your facilities.・When expanding facilities, install the UM33A on site for
data monitoring・Monitor items under test on site without affecting
upstream systems
Administration building
UM33A
Level meter
LN90
4-20mA DC
FN110-R1
Modbus slave
Tank
Site
GX20
Modbus master
PLC
FreezerRefrigerator
UM33A
Temp./humidity sensor
Temp./humidity sensor
Modbus master
Modbus data monitor
RS-485
Storehouse
PCPC
Modbus master
Centralized monitoring of upstream devices
Centralized monitoring of upstream devices
Modbus slave
Administration building
UM33A
Concentration sensor
Concentration sensor
Concentration sensor
Modbus data monitor
Modbus master
RS-485RS-485Expansion
Digital Indicator with Alarms UM33A/S006 Modbus RTU Master/Data Monitor Function
Model and suffix codes
Functions and characteristics
UM33A-010-1//S006
: Sufix code 0 (white case) or 1 (black case): Optional suffix codes
/LP(24 V DC loop power supply), /DC(Power supply 24 V AC/DC), /CT(Coating), /CV(Terminal cover)/S006: RS485 communication (max. 38.4 kbps, 2-wire/4-wire), Modbus RTU master/monitor function)
NOTE: RS485 protocol communication (PC link, ladder, Modbus (RTU/ASCII slave)) not supported.Certifications: CSA, UL, CE, RCM, KC marking
Digital Indicator with Alarms
Co-innovating tomorrow and UTAdvanced are registered trademarks of Yokogawa Electric Corporation.Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries.Other company names and product names appearing in this document are registered trademarks or trademarks of their respective holders.
Modbus/RTU master function
Read out status of Modbus slave sensors and devices on the same line.
Modbus/RTU data monitoring function
Monitor communications between master and slaves on the same line.
UM33AGX20
Sensor
Slaves
Modbus master
Response
Request
UM33A
Sensor
Modbus master
Response
Request
Slaves
Automatic displayed data switching function
The UM33A display can automatically switch between monitored data values.You can also switch manually.
UM33A UM33A
Sensor
No.1
No.1 No.2 No.3 No.8
No.2 No.3 No.8
Up to 8 values
Modbus master
Response
Request
Modbus slaves
・ ・ ・
・ ・ ・
Data abnormality detection function
Monitor the status of data acquired with the master and data monitoring functions, and detect abnormalities.
Sensor
Max. 4 alarms
Modbus master
Response
Request
Modbus slaves
Normal Abnormal
Monitoring (reads communication data)
YOKOGAWA ELECTRIC CORPORATIONControl Instruments Business Division http://www.yokogawa.com/E-mail: [email protected] CORPORATION OF AMERICA http://www.yokogawa.com/us/YOKOGAWA EUROPE B.V. http://www.yokogawa.com/eu/YOKOGAWA ENGINEERING ASIA PTE. LTD. http://www.yokogawa.com/sg/ KP-S-1ESubject to change without notice.All Rights Reserved. Copyright© 2018, Yokogawa Electric Corporation