Difference in Load readings between Strain Gage and Load Cell
-
Upload
govtech-singapore -
Category
Engineering
-
view
55 -
download
8
Transcript of Difference in Load readings between Strain Gage and Load Cell
![Page 1: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/1.jpg)
Problem statement:-
Why there is difference
between Vibrating Wire
Strain Gage and Load
Cell readings during
pre-loading
![Page 2: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/2.jpg)
How does Vibrating
Wire Strain Gage
Work ?
![Page 3: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/3.jpg)
VW gage
Pluck Coil
Vibrating Wire Strain Gage (VWSG)
Functionality
![Page 4: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/4.jpg)
Strain is proportional to Frequency
x Frequency.
A 5% error in Frequency Reading
is a 25 % Strain calculation
![Page 5: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/5.jpg)
= (0.03% of FSD)
In VWSG, we are monitoring the change in load over
time. Sensitivity or Resolution is more critical than
absolute level as we zero it
![Page 6: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/6.jpg)
y = 1.0921x + 11.065
-2000.00
-1500.00
-1000.00
-500.00
0.00
500.00
-1800 -1600 -1400 -1200 -1000 -800 -600 -400 -200 0
Computed Strain (uE)
Esti
mat
ed
Str
ain
(u
E)
Series1
Linear (Series1)
Tritech
Instrument
Laboratory
Test Results
Linear
Regression of
Measured vs
Calculated Strain
m = 1.092
C = 11.065
![Page 7: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/7.jpg)
Welding can cause
Vibrating Wire Strain
Gage Errors
![Page 8: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/8.jpg)
0
500
1000
1500
2000
2500
00:00:00 12:00:00 00:00:00 12:00:00 00:00:00 12:00:00 00:00:00 12:00:00 00:00:00 12:00:00 00:00:00 12:00:00
Time
Load
(kN
)
SG Welding side
SG Non Welding side
Construction Impact - Welding
Load increase (600kN)
due to welding
Welding
Sudden decrease in load (400kN)
due to EMI effect of welding
SG on the side of
welding of strut
SG on the non welding
side of strut
Welding side
![Page 9: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/9.jpg)
How does Vibrating
Wire Strain Load Cell
Work ?
![Page 10: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/10.jpg)
+/- 20% is actually 40% possible difference
![Page 11: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/11.jpg)
![Page 12: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/12.jpg)
Why use Vibrating
Wire Strain Gage?
![Page 13: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/13.jpg)
A comparison
• US $200 each
• Measures less than 1% of strut cross sectional area
• US $4000 eachmeasures the full load
Strain Gauges Load Cells
LTA : 25% of all struts for deep excavations shall
be monitored for load by strain gauge and/or load
cell, and of those monitored by strain gauge 15%
shall also be monitored by load cell.
![Page 14: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/14.jpg)
Known Documented
reading differences
between VWSG and
Load Cell readings
![Page 15: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/15.jpg)
Comparison of Results between
Load Cells and Strain Gauges
Average 30%
difference @ low
load levels
![Page 16: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/16.jpg)
Actual VWSG and Load Cell
installations.
Only under ideal single strut
loading (without bracing) can
the readings be correlate
better
VWSG gives localize strain
while Load Cell gives global
strain
![Page 17: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/17.jpg)
![Page 18: Difference in Load readings between Strain Gage and Load Cell](https://reader033.fdocuments.us/reader033/viewer/2022051502/58ef69f21a28abdf178b45f5/html5/thumbnails/18.jpg)
Strain Gage installation