Standard Generating set Features
Engine Specifi cations
Alternator Specifi cations
Compliance Standards
Engine - GE8V228, EFI diesel engine, heavy duty, 1000rpm / 900rpm.Alternator - Double bearing, Class F insulation, Different voltage range is available.Air fi lter.Cooling system - Tropical remote radiator, heavy duty, 50°C with no derating.Air Starting System
Base Frame - Heavy duty steel base frame, with Spring type anti-vibration mounts.Exhaust - Residential type muffl er, fl exible stainless steel bellows, Noise Attenua-tion, Exhaust Temperature Monitoring and ProtectionAutomatic Control Panel - Control, moni-toring, protection, synchronizing.
Genset Confi guration Type:Open set Enclosed set - Sound & weather proof, ventilation, Air fi ltration.Switchgear - Metalclad withdrawable 3.3/6.6/11KV, 630A, vacuum or SF6 Switchgear - Air Circuit Breaker (ACB) 2500/3200A for Low Voltage: 0.38/0.4/0.415 kV(for single units only).Compliance Standards - ISO9001 / ISO3046 / ISO8528
GE 8V228
V-Type Direct Injection8-cylinder Diesel EngineIdle Speed 440 rpmRated Speed 50 Hz: 1000 rpmRated Speed 60 Hz: 900 rpm
Brushless double bearing, revolving fi eld6-poles for 50Hz 1000rpm8-pole for 60Hz 900rpmWinding Pitch: ca.5/6Cooling: IC01-Open Circuit Ventilation Enclosure: IP23Heavy Duty BearingClass F Insulation (Stator and Rotor)
The generating set complies with ISO 3046, ISO 8528.
Bearing Temperature Detectors (2xPT100 per phase) monitoring and protectionTeminal Box for connectionAlternator Sand FilterAlternator meets IEC 60034Voltage: 0.4, 3.3, 6.6, 6.9, 11, 13.8 KV50 Hz/60 Hz
Elastic Coupling used for a perfect alignment between Engine/Alternator4 Terminals Star point connected in terminal boxStator Temperature Detectors(2xPT100 per phase) monitoring and protection
EFI controller: (Governor)
Engine Governor Unit (EC2+)Engine Inputs Outputs
Construction
4 Valves per Cylinder Forged Steel
Type
4 Stroke, Electronic Fuel Injection
Prime Rating (PRP) Continuous Rating (Cont)
50Hz/1000 rpm
60Hz/900 rpm
1917 kVA1534 kWe1725 kVA1380 kWe
1744 kVA1395 kwe1569 kVA1255 kwe
Diesel Powered Generating Set
MBH1900DMwww.MBH.de
Intake Air System
Heavy Duty Intake Air FilterDuct for distribution air inletMechanical Gauge for Air Differential Pressure with Alarming Contact
Auxiliaries’ Transformer (In case of MV Output)
Designed and rated based on the Gen-set auxiliaries:- Dry type or Oil type- Equipped with Buchholz Relay- Temperature Monitor Control Panel for alarm and trip - Connection: Yno-yn
Exhaust System
Silencer Residential TypeStainless Steel BellowExhaust pipe Jacketing (In case of enclosed set)
Auxiliaries
Electrical System
Air Starting System
Base Mounted Air Compressors (qty=1)Vertical Air Tank Receiver of 500Lt capac-ity (1000 Liters Optional)Mechanical gauge for starting air pressure indicator with alarming contact.Pressure gauge indicator installed on the air tank receiver.Air motor starter solenoid (24VDC)Compressors Control Panel (Compressors Redundancy)Pressure Switches:- Low Pressure Alarm- Start 1st Compressor- High Pressure Alarm
Voltage Regulation
The voltage Regulator provides ±0.25% regulationThree protection functions: fi eld overvoltage, and loss of sensingProgrammable stability settings to optimize transient performance
Fuel System Specifi cation
Fuel Water SeparatorManual and/or automatic fuel pumpDuplex fuel oil fi lterMechanical Gauge for Fuel oil pressure with alarming contact
Oil System
Lube Oil FilterLube Oil/HT water preheating systemPre-lube oil pumpCentrifugal-Self Cleaning Oil Filter with alarming contact to control panelMechanical Gauge for Engine Lube Oil Inlet Temperature with alarming contactMechanical Gauge Lube Oil pressure with alarming contact
Water System
LT/HT table radiator with electrical cooling fans.Engine driven water pumpDrain Cooling fansThermostatic ValvesHT Water Pre-Heating System Mechanical Gauge for Water Pressure Inlet with alarming contactMechanical Gauge for Water Temperature with alarming contactExpansion Tank
Frequency Regulation
Isochronous under varying loads from no load to 100% full load
Random Frequency Variation
Will not exceed ±0.25 of its mean value for constant load
MBH1900DM
LV Distribution Panel-Motor Control Center
To supply and sense all the generating auxiliaries such as: Radiator Fans, Engine Air Inlet Fans, Air Compressors, Pre-lube Pump, DC Charger, Swg Power Supply.Auxiliaries Auto/off/manual selectorFault/run LEDSpare circuit for future useSupply Available LEDs (R,S,T)Fixed Type, total coordination
Start-up Generator (Optional)
In case of a mains power supply, the Start-up Generator can be started either manually by the operator or automatically following a mains failure to supply the Gen-set auxiliaries:- Pre-heater- Pre-lube- Air CompressorsThe BOG is rated accordingly.Medium Voltage Switchgear
(In case of MV Output)
Rated Voltage: 11KV or 6.6KV (for other voltages please refer to company)IP 4XMV Circuit Breaker3 PolesGenerator Management and protection Outgoing with fuse protection for Genset auxiliaries transformer (Optional)
Low Voltage Breaker (In case of LV Output)
ACB from GE or Mitsubishi or equivalent
Control System
DC Panel
2x100AH Batteries with a suitable battery charger (24VDC/20A) sized to suit all DC components: - Generator Control Panel - Auxiliaries; transformer control panel - MCC PanelNote: In case of 110VDC additional set of batteries with suitable battery charger are available
Genset Controller
Operation Mode- Automatic Mains Failure- Island Operation- Fixed Power/Base load- Peak Shaving- Load Take Over- Mains Power Export
Protection (ANSI) - Over Current- Reversed Power- Oil Pressure / Temperature- Cooling Water Pressure / Temperature- Fuel Level
Engine Control- Start/Stop/Pre-lube sequence- Generator breaker Closing/Opening/ Synchronizing sequence.- Run and Stop Coil.- Relay output for Governor Control- Relay output for AVR Control- Different Operation Mode- Modbus (TCP/IP) Communication Port
Genset Local Display
Controlling and Monitoring of the System via Touch ScreenTouch Buttons for Generator Set Operation Modes and Start/Stop SequenceTouch Buttons for Generator Breaker Open/Close OperationsAlarm List DisplayData Monitoring Window and TrendingConnection to AGC Display Port using Ethernet
EFI Controller: (EC2+)
- Variable Fuel Injection Timing- Finer Control of Fuel Volume- Higher Injection Pressure- Reduced Maintenance of Mechanical Components
Human Machine Interface Lube Oil Pump Control System Fuel Control SystemHigh Fuel Level WarningLow Fuel Level WarningLow Fuel Level Shutdown
MBH1900DM
Set Output VoltageContinuous Rating (kWe)Continuous Rating (KVA)Prime Rating (kWe)Prime Rating (KVA)Engine MakeEngine ModelCylindersEngine BuildStandard Governor/ClassAspiration and CoolingBore and StrokeCompression RatioCubic CapacityStartingMininmum Ambient Temp.Engine Coolant Capacity
Direction of Rotation (Flywheel)Gross Engine Output (Prime)Gross Engine Input (LTP) Alternator Voltage Regulation Set Output Frequency Speed Alternator Insulation ClassFuel consumption Prime (LTP)Recommended FuelLubrication System Oil CapacityCoolant CapacityExhaust Temperature @ rated loadExhaust Gas pressure (max) Exhaust Gas FlowRadiator*Fan Temperature (IN/OUT)Lubrication Oil Consumption
50 Hz
* Based on site ambient condition
60 Hz 50 Hz 60 Hz 0.4, 3.3, 6.6, 6.9, 11, 13.8
1395
1744
1534
1917
GE
8 V228
8
V-Type
EFI-Electronic
Turbocharged-intercooled
228.6mmx266.7mm
15.7 : 1
87.6 Liters
Air Starter
5ºC
151 Liters
1255
1569
1380
1725
GE
8 V228
8
V-Type
EFI-Electronic
228.6mmx266.7mm
15.7 : 1
87.6 Liters
Air Starter
5ºC
151 Liters
CCW
1598 KWm
1743 kWm
±0.25 %
50 Hz
1000 RPM
Class F
371 Liters/Hr
#2 Diesel
606 Liters
TBD
427 °C
24.9 mbar
6 m3/s
TBD
50/70ºC
1.0 Liter/Hr
CCW
1438 KWm
1569 kWm
±0.25 %
60 Hz
900 RPM
Class F
319 Liters/Hr
#2 Diesel
606 liters
TBD
427°C
24.9 mbar
5.4 m3/s
TBD
50/70ºC
0.9 Liters/Hr
TECHNICAL DATA
Generating Set Options
Fire Alarm SystemManual Synchronizing FeatureRemote Monitoring Station (Up to 4 Gen-Sets)
Extended Air Tank Receiver Capacity (1000 Liters)Additional Air Compressor for Redun-dancy OperationSpace Heater single Phase for Alternator
Black Start and/or Emergency Application Features:- Black Start Control System (Auto Black Start and Manual Black Start)- Emergency Diesel Generator- Mimic panel
Dimensions and Weight-OPEN SET
Dimensions and Weight-ENCLOSED SET
Dimensions and Weight-ELECTRICAL ROOM (OPTIONAL)
ModelMBH1900DM
Open
Air Tank Receiver Rack
ModelMBH1900DM
Electrical Room (Optional)ISO Radiator
ModelMBH1900DM
Enclosed
Length(mm)8824
3500
Length(mm)5940
Length(mm)12000
Width(mm)2700
1380
Width(mm)2360
Width(mm)3500
Height(mm)3250
2430
Height(mm)2390
Height(mm)3450
Set Weight(kg)
33000
2000
Set Weight(kg)7000
Enclosed Weight(kg)
42000
DS-MBH۱۹۰۰DM-۰۱-C
Maschinenbau Halberstadt GmbH, Rudolf-Diesel-Strasse ۳۸۸۲۰ ,٥۰ Halberstadt, GermanyT. ۳۲۰ ۳۹٤۱ ٤۹+, F. ۲٤۰۳٦ ۳۹٤۱ ٤۹[email protected] - www.MBH.de
Specifi cations may change without notice. Check with your distributor for more information.
Depends on project