df350spec
description
Transcript of df350spec
HDS DOCUMENT CONTROL PROPRIETARY DOCUMENTATION
HDS REVISION NOTICE
Page 1 of 1
HDS Document Number: FE-98DF327-2
ECN/FCB Number: See Hitachi Change Record
HTC Drawing Number: K6601299
HDS Product: 5700E (DF350)Disk Subsystem Date: 6/99
DocumentTitle: 5700E (DF350) Disk Subsystem Specification
DOCUMENT REVISION LEVELInstructions: Add revised sheets and dispose of superseded sheets as indicated by the mostcurrent revision level. (Please see Notes.)
DATEHITACHIREVISION
LEVEL
HDS REVISION
LEVEL DESCRIPTION OF REVISION
6/98
11/98
2/99
6/99
0-7
8
9
9
0
1S
1U1
2
Original HDS Edition.
All sheets are revised. This revision supersedes and replacesprevious HDS editions.HDS Document Order #FE-98DF327-1S
See the Hitachi, Ltd. Revision Control sheet for details of thisrevision. This revision may be ordered as a separate package tobe used as a base manual supplement.HDS Document Order #FE-98DF327-1U1
No changes have been created by Hitachi, Ltd. Previouslyprinted revisions have been incorporated into a new base manualfor reprinting purposes only.HDS Document Order #FE-98DF327-2
NOTES:1. Prior to disposal of superseded documents or sheets, please review applicable HDS policies and
procedures on the disposal of proprietary or classified information.2. To provide a historical revision record, please file this HDS Revision Notice sheet in the back of the
revised manual.
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0000REV.9 Mar.1997 Jul.1997 Dec.1997 Feb.1998 May.1998 Oct.1998
DF350 Disk SubsystemSPECIFICATION
Rev.9Read this manual carefully and keep it.
y Before starting operation, read the safety instructions carefully andfully understand them.
y After reading this manual, keep it at hand for your reference.
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0010REV.7 Mar.1997 Jul.1997 Dec.1997 Feb.1998
REVISION CONTROL
Legend for revision codes : AD : Addition CH : Change CR : Correction DL : Deletion
REV. Date DRW. CHKD APPDSheetNo.
Description Code
0 Mar.10.’97 A.Yamanashi K.Kozawa M.Sato All Issued1 - 4
(Noting)5 Jul.30.’97 A.Yamanashi Y.Morishita M.Sato All All pages were reviewed
corresponding to addition of DK type.6 Dec.20.’97 A.Yamanashi Y.Morishita M.Sato 0020 4.2 was added. AD
0030 5.3 was added. AD0070 The text(DKH) was added to the
Capter 1. (The desktop type⋅⋅⋅.)AD
0080 DKH was added to table1.1. AD0100 DKH was added in a table. AD
Maintenance specification was movedto SPEC0110.
DL
0110 Maintenance specification was movedfrom SPEC0100
AD
Startup time, Breaking current,Insulation performance was added in atable.
AD
*3, 4, 5 was moved to SPEC0120. DL0120 *3. 4. 5 was moved from SPEC0110. AD
*9was added. AD0130 DKH type was added. AD0160 DKH figure was added. AD0190 Changed the figure. (DK/DKH/MK) AD/CH0220 *1, 3 was added. AD
Changed the figure. (single phase) CH0230 ″Disk drive power supply″ and
″Cache Memory″ were deleted.DL
0240 ″Cache memory″ was deleted. DL0242 This page was newly added. AD0244 This page was newly added. AD0246 This page was newly added. AD0250 *3 was added. AD
Changed the 4.2 and 4.2.1. CH0260 Changed the 4.2.2. CH
Changed the Selection of Disk drive. CH0280 Changed the 4.3 and 4.3.1. CH
Changed the figure. (single phase) CH0310 Changed the 4.4 and 4.4.1. CH
Changed the figure. (single phase) CH0320 Changed the 4.4.2. CH
Changed the Selection of Disk drive. CH*3 was added. AD
0340 Changed the 4.5 and 4.5.1. CH0350 Changed the 4.5.2. CH
Changed the Selection Disk drive. CH0370 Changed the 4.6. CH
DF-350-J2 / DF-350-J3 was added tothe power cable.
AD
0410 Changed the (b) CH0610 This page was newly added. AD
7 Feb.10.’98 A.Yamanashi Y.Morishita H.Iwasaki 0015 PREFACE was added. AD0060 CAUTION was added. AD
0061-0066
These page were newly added. AD
0080 RAIDA was added. AD0100 Changed in a table. CH0110 Changed in a table CH0120 CAUTION/*10 were added. AD
DF350 K6601299-
Copyright © 1998, Hitachi, Ltd.
SPEC0011REV.2 Feb.1998 May.1998 Oct.1998
REVISION CONTROL
Legend for revision codes : AD : Addition CH : Change CR : Correction DL : Deletion
REV. Date DRW. CHKD APPDSheetNo.
Description Code
0130 Instantaneous power failure. AD0160 Split the DK/DKH. CH0260 Added “A1E8A”. (Pages 0270, 0290,
0300, 0320 and 0330 were changed bythe same reason.)
AD
0380 Added “Remodeling kit”. AD8 May.20.’98 A.Yamanashi Y.Morishita H.Iwasaki All “DF350” was added as an item of the
header. (Revision number of each pagewas left unchanged.)
AD
0065 DKH types label was changed. CH0080 Table 1.1/1.2 was changed. CH0100 Changed ‘Subsystem data capacity’
on table..CH
0110 Changed ‘Energy saving’ on table. CH0130 Added ‘When the A1E18 is
installed,...’.AD
0230 Added A2E8/E2E8. AD0240 Added A2E8. AD0244 Added A2E8/E2E8/A1E18/E1E18. AD0246 Added A2E8/E2E8/A1E18/E1E18. AD0260 Added A2E8/E2E8/A1E18/E1E18. AD0265 This page was newly added. AD0270 Added A2E8/E2E8/A1E18/E1E18. AD0290 Added A2E8/E2E8/A1E18/E1E18. AD0295 This page was newly added. AD0300 Added A2E8/E2E8/A1E18/E1E18. AD0305 This page was newly added. AD0320 Added A2E8/E2E8/A1E18/E1E18. AD0325 This page was newly added. AD0330 Added A2E8/E2E8/A1E18/E1E18. AD0335 This page was newly added. AD0350 Added A2E8/E2E8/A1E18/E1E18/
A2E4A/E2E4A/A1E8A/E1E8A.AD
0355 This page was newly added. AD0360 Added A2E8/E2E8/A1E18/E1E18/
A2E4A/E2E4A/A1E8A/E1E8A.AD
0365 This page was newly added. AD0380 Added “DF-F350-URASD, DF-F350-
URHPD, DF-F350-URRA”.AD
9 Oct.15.’98 A.Yamanashi 0080 Added A3E4. AD0230 Added A3E4, E3E4. AD0240 Added A3E4. AD0244 Added A3E4, E3E4. AD0246 Added A3E4. AD0250 Added *4. AD0260 Added *3, A3E4, A2E8A, E3E4,
E2E8A./Deleted “Disk drive powersupply”.
AD/DL
0265 Added “Disk drive power supply”./Changed *3→*4.
AD/CH
0270 Added A3E4, A2E8A./ Deledted“Array controller” and “PC formaintenance”.
AD/DL
0275 This page was newly added. AD
DF350 K6601299-
Copyright © 1998, Hitachi, Ltd.
SPEC0012REV.0 Oct.1998
REVISION CONTROL
Legend for revision codes : AD : Addition CH : Change CR : Correction DL : Deletion
REV. Date DRW. CHKD APPDSheetNo.
Description Code
0290 Added A3E4, A2E8A, E3E4,E2E8A./Deleted “Disk drive powersupply”.
AD/DL
0295 Added “Disk drive power supply”. AD0300 Added A3E4, A2E8A, E3E4,
E2E8A./Deleted “Additional diskdrive”.
AD/DL
0305 Added “Additional disk drive”, E3E4,E2E8A.
AD
0320 Added A3E4, A2E8A, E3E4,E2E8A./Deleted “Disk drive powersupply”.
AD/DL
0325 Added Deleted “Disk drive powersupply”.
AD
0330 Added A3E4, A2E8A./Deleted“Additional disk drive”.
AD/DL
0335 Added “Additional disk drive”, A3E4,A2E8A, E3E4, E2E8A.
AD
0350 Added A3E4, A2E8A, E3E4,E2E8A./Deleted *1, *2.
AD/DL
0355 Added *1, *2. AD0360 Added A3E4, A2E8A./Deleted
“Additional disk drive”.AD/DL
0365 Added “Additional disk drive”, A3E4,A2E8A, E3E4, E2E8A
AD
DF350 K6601299-
Copyright © 1998, Hitachi, Ltd.
SPEC0015REV.0 Feb.1998
PREFACE
z This manual describes specifications and interface of the DF350 disk array subsystem.
z For the procedure for installing the subsystem, refer to the user’s operation manual.
z For maintenance works such as replacement of maintenance parts and troubleshooting, refer
to the maintenance manual.
z Keep this manual at hand so that you can use it at any time.
z Copyrights of this manual are reserved by Hitachi, Ltd.
Contents of this manual cannot be reproduced or copied, in whole or in part, without
permission of Hitachi, Ltd.
z Contents of this manual are subject to change without prior notice.
z It must be noted that Hitachi, Ltd. shall not be liable for the result of operation which is not
described in this manual.
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0020REV.6 Mar.1997 Jul.1997 Dec.1997
CONTENTS
! SAFETY SUMMARY......................................................................................................................SPEC0040
1. Outline............................................................................................................................................SPEC0070
1.1 Outline of Functions................................................................................................................SPEC0070
1.2 Precautions on Use.................................................................................................................SPEC0090
2. Basic Specifications .......................................................................................................................SPEC0100
2.1 Basic Specifications................................................................................................................SPEC0100
2.2 Environmental Specifications and Reliability ..........................................................................SPEC0130
2.3 Handling..................................................................................................................................SPEC0140
2.3.1 Packing............................................................................................................................SPEC0140
2.3.2 Transportation .................................................................................................................SPEC0140
2.3.3 Storage ............................................................................................................................SPEC0140
2.4 Battery Storage .......................................................................................................................SPEC0150
3. Appearance....................................................................................................................................SPEC0160
3.1 Appearance of DF350 Subsystem..........................................................................................SPEC0160
3.2 Maintenance Area...................................................................................................................SPEC0190
4. System Configuration.....................................................................................................................SPEC0220
4.1 Desktop Type (DK) .................................................................................................................SPEC0220
4.1.1 Desktop type (DK) configuration......................................................................................SPEC0220
4.1.2 List of desktop type (DK) component models..................................................................SPEC0230
4.2 Desktop Type (DKH)...............................................................................................................SPEC0242
4.2.1 Desktop type (DKH) configuration ...................................................................................SPEC0242
4.2.2 List of desktop type (DKH) component models ...............................................................SPEC0244
4.3 Mini Tower Type .....................................................................................................................SPEC0250
4.3.1 Mini tower type configuration ...........................................................................................SPEC0250
4.3.2 List of mini tower type component models ......................................................................SPEC0260
4.4 Cabinet Type...........................................................................................................................SPEC0280
4.4.1 Cabinet type configuration ...............................................................................................SPEC0280
4.4.2 List of cabinet type component models ...........................................................................SPEC0290
4.5 Rack Mount (RKH) Type.........................................................................................................SPEC0310
4.5.1 Rack mount (RKH) type configuration .............................................................................SPEC0310
4.5.2 List of rack mount (RKH) type component models..........................................................SPEC0320
4.6 Rack Mount (RKWH) Type .....................................................................................................SPEC0340
4.6.1 Rack mount (RKWH) type configuration .........................................................................SPEC0340
4.6.2 List of rack mount (RKWH) type component models ......................................................SPEC0350
4.7 Accessories ............................................................................................................................SPEC0370
4.8 Rack Frames ..........................................................................................................................SPEC0390
4.8.1 U1 rack frame..................................................................................................................SPEC0390
4.8.2 U2 rack frame..................................................................................................................SPEC0390
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0030REV.6 Mar.1997 Jul.1997 Dec.1997
5. Interface .........................................................................................................................................SPEC0400
5.1 SCSI Connection Specifications .............................................................................................SPEC0400
5.1.1 Interface cable (daisy-chain connection) .........................................................................SPEC0400
5.1.2 System configuration .......................................................................................................SPEC0410
5.1.3 Cable-side connector.......................................................................................................SPEC0420
5.1.4 Cable ...............................................................................................................................SPEC0420
5.1.5 Equipment-side connector shape (for pin-type connector)..............................................SPEC0420
5.1.6 Connector pin layout (for dIfferential SCSI) .....................................................................SPEC0430
5.1.7 Interface circuit (for differential ended SCSI)...................................................................SPEC0450
5.1.8 Interface signal characteristics (for differential ended SCSI) ..........................................SPEC0450
5.1.9 Interface circuit (for single ended SCSI)..........................................................................SPEC0460
5.1.10 Interface signal characteristics (for single ended SCSI)..................................................SPEC0460
5.1.11 SCSI bus signal ...............................................................................................................SPEC0470
5.1.12 Bus phase........................................................................................................................SPEC0500
5.1.13 Software outline (supported commands).........................................................................SPEC0530
5.1.14 Message ..........................................................................................................................SPEC0540
5.1.15 Status...............................................................................................................................SPEC0550
5.2 RS232C ..................................................................................................................................SPEC0570
5.2.1 DF350 connector pin layout.............................................................................................SPEC0570
5.2.2 RS232C cable (S1)..........................................................................................................SPEC0580
5.2.3 RS232C cable (SH2, SH3) ..............................................................................................SPEC0590
5.2.4 RS232C cable (SS2, SS3)...............................................................................................SPEC0600
5.3 Power Cable ...........................................................................................................................SPEC0610
5.3.1 Power cable (J1)..............................................................................................................SPEC0610
5.3.2 Power cable (J2)..............................................................................................................SPEC0610
5.3.3 Power cable (J3)..............................................................................................................SPEC0610
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0040REV.5 Mar.1997 Jul.1997
! SAFETY SUMMARY
01. ! General Safety Guidelines
Read the following safety guidelines carefully and follow them when you conduct maintenance of the machine.
Before starting maintenance
• Maintenance of the machine must be done only by trained and qualified engineers.
• Read and follow the safety guidelines and procedures in this manuals.
• In this manual and on the machine, hazard warnings are provided to aid you in preventing or reducing the risk
of death, personal injury, or product damege. Understand and follow these hazard warnings fully.
• The hazard warning which appear on the warning labels on the machine or in the manual have one of the
following alert headings WARNING, or CAUTION.
! DANGER : Indicates an imminently hazardous situation which, if not avoided, willresult in death or serious injury.
! WARNING : Indicates a potentially hazardous situation which, if not avoided, can resultin death or serious injury.
! CAUTION : Indicates a potentially hazardous situation which, if not avoided, will or canresult in minor or moderate injury, or serious damage of product.
The alert symbol shown left precedes every signal word for hazardwarnings, and appears in safety related descriptions in the manual.!
The signal word ‘NOTICE’ is used to present warnings which are not directly related to personal injury
hazards.
• Do not perform any operation or action in any way other than as provided in this manual.
• Keep in mind that the hazard warnings in this manual or on the machine cannot cover every possible case, as it
is impossible to predict and evaluate all circumstances beforehand.
Be alert and use your common sense.
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0050REV.5 Jul.1997
! SAFETY SUMMARY (Continued)
01.1 Environmental conditions
A suitable environment and handling are necessary to use the DF350 disk array subsystem for a long period of
time without its functions being deteriorated. Do not install the subsystem in any of the locations shown below.
Otherwise, the life of the subsystem may be shortened or the subsystem may become out of order.
• Location exposed to direct sunlight.
• Location where the temperature and humidity change rapidly. (Close to an air-conditioner for example.)
• Close to a device which generates electrical noises. (Motor for example.)
• Close to a device which generates a strong magnetic field. (Do not bring a magnet close to the subsystem.)
• Location where dirt and dust are generated.
• Location where vibration is transmitted.
01.2 Installing conditions
(1) Weighting
Do not sit on the DF350 nor anything heavy put on it.
(2) Ventilation
The DF350 takes in cooling air from the louver in front and discharge it through the slits on the rear side.
Do not cover those ventilating holes.
For the Rack mount type (RKH) subsystem only, do not cover the slits on the left side (when looking from
the front) of the subsystem since the air is discharged from it.
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0060REV.6 Mar.1997 Jul.1997 Feb.1998
! SAFETY SUMMARY (Continued)
02. ! Hazard Warning Statements
This Product Specifications mainly contains information on specifications and interface of the subsystem. For
warnings and notes on operations and works necessary to handle the subsystem safely, see each manual such as
the User’s Operating Manual.
(1) This subsystem is provided with ventilating holes on the covers in order to prevent overheating. Therefore,
do not cover those holes. Otherwise, overheating may cause a fire or a failure of the subsystem.
(2) Use specified optional parts, cables, and connectors. Otherwise, a fire, a personal injury, or a failure of the
subsystem may be caused as well as the deterioration of the performance.
(3) If an abnormal odor, generation of heat, or smoke is sensed, turn off the power supplied to the subsystem
from the distribution panel immediately and contact your service personned. Use of the machine that is out of
order can cause a fire or an electric shock.
(4) Do not sit on the DF350 nor anything heavy put on it. Otherwise, the subsystem may fall and cause personal
injury.
(5) Do not put containers with water or metal articles on top of the subsystem. They can cause a fire, an electric
shock, or a failure of the subsystem if the water spills and gets in the subsystem.
The following are the hazard warning statements contained in this manual.
! DANGER statement
No DANGER statement.
! WARNING statement
No WARNING statement.
! CAUTION statements
No CAUTION statement.
For safety upon disposal/storage of the battery, the following must be strictly observed :
CAUTION!
Also, there is a limitation on the weight. Contact us before mounting the desktop type (DKH), rackmount type (RKH) and (RKWH) on rack other than the U1 rack and U2 rack made by Hitachi.
(SPEC0120)
The battery contains a poisonous substance. An electric shock may be caused by inappropriate handling.
Be sure to follow the instructions below.
(1) Do not disassemble or remake the battery.
(2) Do not deform the battery.
(3) Do not connect (+) pole to (-) pole with metallic article such as a steel wire.
(4) Do not reverse (+) and (-) poles.
(5) Do not peel off the covering tube.
(6) Do not connect the battery directly to the outlet.
(7) Do not connect the battery to anything other than this subsystem for
charging/discharging.
(8) Do not leave the battery at a hot place. Store the battery in a dark, cool place.
(SPEC0150)
Do not place it on the unstable place, on the shaky table, or the inclined place, etc.
Dropping or a fall of it may cause an injury. (SPEC0190)
DF350 K6601299-
Copyright ©1998, Hitachi, Ltd.
SPEC0061REV.0 Feb.1998
! SAFETY SUMMARY (Continued)
03. ! Locations where WARNING and CAUTION labels are affixed.
Locations where WARNING and CAUTION labels are affixed are shown below.
Front FrontDesktopp type (DK) Desktop type (DKH)
Front
Mini tower / Cabinet type
DF350 K6601299-
Copyright ©1998, Hitachi, Ltd.
SPEC0062REV.0 Feb.1998
! SAFETY SUMMARY (Continued)
Front
Rear
Rack mount type (RKH)
DF350 K6601299-
Copyright ©1998, Hitachi, Ltd.
SPEC0063REV.0 Feb.1998
! SAFETY SUMMARY (Continued)
Front
Rear
Rack mount type (RKWH)
DF350 K6601299-
Copyright ©1998, Hitachi, Ltd.
SPEC0064REV.0 Feb.1998
! SAFETY SUMMARY (Continued)
Front
Rack mount type (RKWH)
DF350 K6601299-
Copyright ©1998, Hitachi, Ltd.
SPEC0065REV.1 Feb.1998 May.1998
! SAFETY SUMMARY (Continued)
Rack mount type (RKH)
Rack mount type (RKWH) Desktop type (DKH)
(Rack mount)
DF350 K6601299-
Copyright ©1998, Hitachi, Ltd.
SPEC0066REV.0 Feb.1998
! SAFETY SUMMARY (Continued)
Because there exist hazardous areas of electric shock, perform the part(s)
removal following the procedures instructed in this manual.
Desktop type (DK)
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0070REV.6 Mar.1997 Jul.1997 Dec.1997
1. Outline
The DF350 series disk array subsystem is a device developed for large capacity data storage, high-speed data
transfer, and high reliability, connecting two (1 row) to twenty-one (4 rows + 1 spare) 3.5” compact magnetic
disk drives.
This subsystem consists of the array controller that controls compact disk drives laid out and connected as an
array and the compact disk drives (five drives in 1 row). As the host interface, the Ultra/Wide-SCSI interface is
used.
There are four types of DF350 subsystems; desktop, mini tower, cabinet, and rack mount. The desktop type is
divided into the DK type and DKH type, and rack mount type is divided into the RKH type and RKWH type. The
rack mount type can be mounted on a dedicated rack cabinet. Up to six sets of the RKH type can be mounted on a
dedicated U1 rack. Up to 4 sets of the RKWH type can be mounted on a dedicated U2 rack.
The DF350 supports RAID0, RAID1, RAID5 (4D+1P, 3D+1P, 2D+1P) and RAID0+1 (called RAIDA later) to
meet these purposes.
1.1 Outline of Functions
(1) SCSI-2 type interface
• The Ultra SCSI interface as the standard interface for small magnetic disk drives allowing high-speed,
high-performance data transfer can be selected.
(2) High-speed data transfer
• By activating multiple compact disk drives concurrently, data can be read and written at a high speed.
• In the Ultra-SCSI configuration, data can be read and written at the maximum speed of 40MB/s.
• By using a large-capacity non-volatile cache (16MB to 1GB/controller), speedup of command processing
when read/write is hit is achieved.
(3) Large capacity
• The DF350 cabinet type or rack mount type allows addition of compact disk drives.
• Up to 21 compact disk drives can be connected, so up to 357.7GB (cabinet/rack mount RKWH for
RAID0) can be realized. Furthermore, the rack mount type can realize up to 1.43TB (RKWH for RAID0)
if a dedicated rack cabinet is used for mounting.
• From the host, this equipment can be used as a large-capacity disk or as up to 8 logical drives.
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0080REV.9 Mar.1997 Jul.1997 Dec.1997 Feb.1998 May.1998 Oct.1998
Table 1.1 Number of Rows and Capacity of Disk ArraysDesktop (DK) Desktop (DKH) Mini tower
Numberof
rowsRAID Capacity (GB)
Numberof
rowsRAID Capacity (GB)
Numberof
rowsRAID Capacity (GB)
1 0 4.1 1 0 4.1 1 0 4.11 2.0 1 2.0 1 2.0
5(4D+1P) 8.2 5(4D+1P) 8.2 5(4D+1P) 8.25(3D+1P) 6.2 5(3D+1P) 6.2 5(3D+1P) 6.25(2D+1P) 4.1 5(2D+1P) 4.1 5(2D+1P) 4.1
A 4.1 A 4.1 A 4.11 0 43.5 1 0 89.4 1 0 89.4
1 17.4 1 35.7 1 35.75(4D+1P) 34.8 5(4D+1P) 71.5 5(4D+1P) 71.55(3D+1P) 26.1 5(3D+1P) 53.6 5(3D+1P) 53.65(2D+1P) 17.4 5(2D+1P) 35.7 5(2D+1P) 35.7
A 17.4 A 35.7 A 35.7Cabinet Rack mount (RKH) Rack mount (RKWH)
Numberof
rowsRAID Capacity (GB)
Numberof
rowsRAID Capacity (GB)
Numberof
rowsRAID Capacity (GB)
1 0 4.1 1 0 4.1 1 0 10.31 2.0 1 2.0 1 4.1
5(4D+1P) 8.2 5(4D+1P) 8.2 5(4D+1P) 8.25(3D+1P) 6.2 5(3D+1P) 6.2 5(3D+1P) 6.25(2D+1P) 4.1 5(2D+1P) 4.1 5(2D+1P) 4.1
A 4.1 A 4.1 A 4.14 0 357.7 2 0 178.8 4 0 357.7
1 143.0 1 71.5 1 143.05(4D+1P) 286.1 5(4D+1P) 143.0 5(4D+1P) 286.15(3D+1P) 214.6 5(3D+1P) 107.3 5(3D+1P) 214.65(2D+1P) 143.0 5(2D+1P) 71.5 5(2D+1P) 143.0
A 143.0 A 71.5 A 143.0
* The capacity per row depends on the capacity of drives to be mounted.
In the minimum configuration, 2.0GB drives are used. The capacity in the RAID0/1 configuration is calculated for the case using
two drives(rack mount (RKWH) type using five/four drives), the capacity in the RAID5 configuration is calculated for the case
using five/four/three drives while the capacity in the RAIDA configuration is calculated for the case using four drives.
In the maximum configurations, it is assumed that the desktop (DK) type uses 8.7GB drives, while the others use 17.8GB drives.
• The number of user bolcks in the entire subsystem can be calculated form the following formula. For conversion into the storage
capacity, multiply the number of blocks by 512.
c RAID5
Number of blocks = m × 4 × Number of mounted rows
d RAID1/RAIDA
Number of blocks = m × int (Number of mounted drives/2) (*1)
e RAID0
Number of blocks = m × Number of mounted drives (*2)
*1 For int, fraction showuld be truncated.
*2 Number of mounted drives is 2 or more.
For the nubmer of blocks (m) per drive, see Table 1.2.
Table 1.2 Number of Blocks (m) and Capacity per DriveDrive name (type) DF-F350-A2E2 DF-F350-A3E4/
DF-F350-A2E4/DF-F350-A2E4A
DF-F350-A2E8/DF-F350-A1E8/
DF-F350-A1E8A
DF-F350-A1E18
Capacity 2.0GB 4.1GB 8.7GB 17.8GBCapacity (user area) per Number of blocks (m) 4,040,192 8,130,432 17,016,832 34,936,320disk drive Capacity (GB) 2.068 4.162 8.712 17.887
Minimumconfiguration
Maximumconfiguration
Minimumconfiguration
Maximumconfiguration
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0090REV.5 Mar.1997 Jul.1997
(4) High data usability
• In the RAID5 configuration, data can be read and written continuously without system down by using the
parity disk drive (1 set/row) against one failed disk drive.
(5) High data reliability
• The DF350 controller automatically generates and adds the original 4-byte data assurance codes to the data
from the host computer and writes the codes on the disk along with the data, thus enhancing data
reliability.
• On the data bus in the controller, the data assurance codes are automatically generated and checked to
enhance data reliability in data distribution/collection control inherent to the array.
(6) Diagnostic and maintenance functions
• With the panel indicator located on the subsystem main unit, subsystem diagnostics and maintenance can
be performed.
• Diagnostics and maintenance of this subsystem can be performed via the maintenance terminal (personal
computer) or LAN connected to the RS232C serial interface on the host computer or controller.
• By using an optional utility program, the equipment state can be checked and the faulty section can be
identified.
• By using a remote maintenance function (SNMP), the diagnosis of the system from an apart place can be
performed.
1.2 Precautions on Use
Be sure to back-up data for data recovery in case data should be lost due to an unexpected hardware
or software failure on the host computer or the DF350.
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0100REV.8 Mar.1997 Jul.1997 Dec.1997 Feb.1998 May.1998
2. Basic Specifications
2.1 Basic SpecificationsType Desktop type Mini Cabinet Rack mount type (*6)
towertype
type (DKH) Standard type(RKH)
Large-capacity type(RKWH)
Item
(DK) (DKH) (MK) (CK) Rackmountable
(per subsystem)
Singleunit
Mountedon U1rack
Singleunit
Mountedon U2rack
Hostinter-
Interface type Ultra-Wide SCSISingle end/Differential
Ultra Wide SCSIDifferential
face Data transfer speed(i.e. maximum speed fortransfer to the host) (*7)
40MB/s (Ultra SCSI)
Transferred block size 512BytesDiskdrive
Drive name 1”H 3.5”HDD
1”H/1.6”H 3.5”HDD
used Data capacity 2.0/4.1/8.7GB
2.0/4.1/8.7/17.8GB
Data transfer speed 9.37 - 15MB/sRevolution speed 7,200rpm
RAID RAID level (*1) 0/1/5(4D+1P, 3D+1P, 2D+1P)/Aspecif-cations
RAIDconfiguration
RAID0(nD)
n=2 - 5 n=2 - 20 n=2 - 5 n=2 - 10 n=(2 - 10)×6
n=5 - 20 n=(5 - 20)×4
RAID1(nD+nD)
n=1 - 2 n=1 - 8 n=1 - 2 n=1 - 4 n=(1 - 4)×6
n=2 - 8 n=(2 - 8)×4
RAID5(4nD+nP)
n=1 n=1 - 4 n=1 n=1 - 2 n=(1 - 2)×6
n=1 - 4 n=(1 - 4)×4
RAID5(3nD+nP)RAID5(2nD+nP)RAIDA(2nD+2nP)
Row configuration 1 row 1 - 4 rows 1 row 1 - 2 rows 1 - 4 rowsSub- Minimum (GB) RAID0 4.1 4.1 10.3system RAID1 2.0 2.0 4.1data RAID5(4D) 8.2 8.2 8.2capa- RAID5(3D) 6.5 6.2 6.2
city RAID5(2D) 4.1 4.1 4.1(*2) RAIDA 4.1 4.1 4.1
Maximum (GB) RAID0 43.5 89.4 357.7 89.4 178.8 1073.2 357.7 1430.9RAID1 17.4 35.7 143.0 35.7 71.5 429.2 143.0 572.3RAID5(4D) 34.8 71.5 286.1 71.5 143.0 858.5 286.1 1144.7RAID5(3D) 26.1 53.6 214.6 53.6 107.3 643.9 214.6 858.5RAID5(2D) 17.4 35.7 143.0 35.7 71.5 429.2 143.0 572.3RAIDA 17.4 35.7 143.0 35.7 71.5 429.2
(@17.8GBDRV)
143.0 572.3(@17.8GB
DRV)Unit ofexpansion (GB)
RAID0 2.0/4.1/8.7/17.8
2.0/4.1/8.7/17.8
RAID1 2.0/4.1/8.7/17.8
2.0/4.1/8.7/17.8
RAID5(4D) 8.2/16.6/34.8/71.5
8.2/16.6/34.8/71.5
RAID5(3D) 6.2/12.4/26.1/53.6
6.2/12.4/26.1/53.6
RAID5(2D) 4.1/8.3/17.4/35.7
4.1/8.3/17.4/35.7
RAIDA 4.1/8.3/17.4/35.7
4.1/8.3/17.4/35.7
Cachespecifi-cations
Capacity 16MB/controller
16 -256MB/
controller
16 - 1,024MB/controller 16 -256MB/
controller
16 - 1,024MB
controller
Up to12,288MB/
dualcontroller
×6
16 - 1,024MB
controller
Up to8,192MB/
dualcontroller
×4Control system Read LRU/Write AfterBattery back up ProvidedBack up time (*3) 48h
(@16MB)48h
(@256MB)48h
(@256MB/contrller/single unit/subsystem)
48h(@256MB)
48h(@256MB/controller/single unit/subsystem)
Internal Control CPU intel 80960CF (@33MHz)logic Control OS VxWorksspecifi- Control memory Flash 1MB/SRAM 512MB/DRAM 4MBcations Data bus performance Cache:106MB/s
Data assurance method Data bus :Through-parityCache :ECC (1 bit for correction, 2 bits for detection)Drive :Data assurance code
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0110REV.8 Mar.1997 Jul.1997 Dec.1997 Feb.1998 May.1998
Type Desktop type Mini Cabinet Rack mount type (*6)towertype
type (DKH) Standard type(RKH)
Large-capacity type(RKWH)
Item
(DK) (DKH) (MK) (CK) Rackmountable
(per subsystem)
Singleunit
Mountedon U1rack
Singleunit
Mountedon U2rack
Redun-dancy
Hot-replaceable part(*10)
Drive/Power supply Controller/Drive/Fan/Power supply
Drive/Powersupply
Controller/Drive/Fan/Power supply
Controller/Drive/Fan/Power supply/In Box
(Dual AC powersupply is used)
Maint- Micro-loading system Flash memory/Disk drive (resident)enancespecifi-cations
SVP (built-in dedicated tool)panel
y Failure information logging/Power controly Controlling microprogram patchy Drive controlling micro-program D/Ly Configuration information changey Drive recovery intiating process (This process is automatic when drive replace)
FDD y Failure and statistics information loggingy Controlling program patch/Drive D/L
Operator panel y Power ON/OFF switch and LEDsy Failure message indication
Physi- Startup time Standard 40sec. (Max. 2min) (*9)calspecifi-
Chassis size (mm)(W×D×H)
150×400×350
170×420×435
230×465×409
300×600×700
483×420×170
484×656×263
800×850×1,790
480×632×442
700×800×1,980
cations Weight (kg)(*4)
19approx.
25approx.
33/37approx.
50/85approx.
25approx.
45/60approx.
/580approx.
84/105approx.
/590approx.
Noise (dB) 55 57 55 65 60 65Input Input voltage (*5) 89 - 127V AC or 178 - 254V AC 178 - 254V ACpower Frequency 50/60Hz ± 1Hzspecifi-
Number of phases, cabling With single-phase protective grounding
cation Nominal current 2.2A(100V)1.2A
(200V)
3.7A(100V)1.9A
(200V)
4.0A(100V)2.0A
(200V)
9.0A(100V)4.5A
(200V)
3.7A(100V)1.9A
(200V)
5.0A(100V)2.5A
(200V)
15.0A(200V)
5.5A
(200V)
22.0A(200V)
Breaking current (A) 6.3 15.0 6.3 7.5 15.0 Required power
(*8)(steady) 240VA 350VA 300VA 800VA 350VA 500VA 3,100VA 900VA 3,600VA
(starting) 360VA 450VA 1100VA 450VA 620VA 3,820VA 1,200VA 4,800VAOpera-t ional
Temperature 10 - 40°C(When the A1E18 is installed, it is recommended to use it within a range from 10°C to 35°C.)
and Humidity 8 - 80%enviro- Maximum wet bulb
temperature29°C (non-condensing)
nment-alspecifi-cations
Vibration Operating : Less than 0.25GNon-operating : Less than 0.5GTransporting : Less than 0.5G
Insula-tion
Insulation withstand voltage 1500V (1min)
perfor-mance
Insulation resisitance DC500V, 10MΩ or more
Energy Capacity 43.5GB 89.4GB 357.7GB 89.4GB 178.8GB 1,073.2GB 357.7GB 1,430.9GBsaving Energy consumption 240W 350W 300W 800W 350W 500W 3,100W 900W 3,600W
Energy consumption efficieney 0.0055W/MB
0.0039W/MB
0.0034W/MB
0.0022W/MB
0.0039W/MB
0.0028W/MB
0.0029W/MB
0.0025W/MB
*1 • RAID0 is a configuration containing a group of single disk drives and does not have redundancy. RAID0
for this subsystem does not support the data striping function.
Notice : RAID5, RAID1 and RAIDA are the configuration with data reliability enhanced as a result of
having redundancy. Data may be lost due to an unexpected hardware or software failure on the
host or array subystem. Be sure to back up all data for data recovery when the data is lost.
*2 • When two or more RAID levels are not mixed.
• This capacity eliminates the control area on each drive.
• This capacity is calculated assuming that 1kbyte = 1,000bytes.
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0120REV.7 Mar.1997 Jul.1997 Dec.1997 Feb.1998
*3 • Time for baking up data on the cahce memory is indicated.
• The battery is fully charged.
• Non-volatility of data on the cache memory is ensured against power supply failures such as a sudden
power failure. When power is normally disconnected, data in the cache is transferred to the disk.
Therefore, the battery is not wasted uselessly.
• If the unit is not energized for more than a month, the over discharging of the battery occurs and it may be
cause an unrecoverable damage. In this case, the battery must be energized more than 24 hours at least
once a month, or store the unit with the switch of the battery off. Even when the switch is off, the battery
discharges naturally. Therefore, turn on the switch of the battery and energize it for 24 hours every three
months to charge it.
*4 • Basic : Minimum configuration (spare disk, redundant controller, redundant power supply not mounted.
However, the desktop type (DK) and large-capacity rack mount type (RKWH) has the power supply and
redundant power supply as the standard components.)
• Maximum : Maximum configuration (all of the mountable disk drives, redundant controller, and redundant
power supply are provided.)
*5 • Use of an uninterruptible power system (UPS) is recommended against sudden power failures.
*6 • The desktop type (DKH), rack mount type (RKH) and (RKWH) are mountable on a 19” rack that is being
sold in the market. In this case, dedicated rack rails corresponding to the number of rack mount type units
to be mounted are required.
CAUTION!
Also, there is a limitation on the weight. Contact us before mounting the desktop type (DKH), rackmount type (RKH) and (RKWH) on rack other than the U1 rack and U2 rack made by Hitachi.
• For any rack mount type mounted on the rack, LED indication on the central panel is used.
• Since the centralized power distributor (for 200V) and centralized power switch are provided on the rack,
power can be turned on/off by using them.
• A cable with single-phase 200V plug is attached to the rack as the standard component. If you want to
connect to the centralized power distributor directly, installation of the power cable is required.
• The plug shape and receptacle for each rack is as follows :
For U1 rack For U2 rackPlug shape NEMA standard L6-20P NEMA standard L6-30P
Receptacle L6-20R L6-30R
• Since the U2 rack uses the dual AC line, prepare two outlets. The dual system is allowed if each power is
led from a different AC line.
*7 •When the interface type in single-ended, the maximum transfer rate will be restricted to 20MB/s.
*8 • Powers required for the maximum configurations are shown.
When planning a facility such as an uninterrupted power supply (UPS), assume the power factor to be
100% (300W=300VA for example). The values shown are those for 100/200 volts. In case the tolerance is
included, the values may be exceeded.
*9 • It may take 2 minutes or more for starting up the subsystem when it is powered on within 30 seconds after
it is powered off. It is because the starting up immediately after powering off is restricted in order to
protect the drive system.
It may also take 2 minutes or more for starting up the subsystem if a failure occurs in it.
*10 •Hot replacement must be done by trained service personnel only (expect the drive).
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0130REV.8 Mar.1997 Jul.1997 Dec.1997 Feb.1998 May.1998
2.2 Environmental Specifications and Reliability
Desktop
(DK)
Desktop
(DKH)
Minitower
Cabinet Rackmount(RKH)
Rackmount
(RKWH)
Remarks
Temperature Operating 10 to 40°C(When the A1E18 is installed, it is recommended to use it
within a range from 10°C to 35°C.)Non operating −10 to 50°CTransporting/storing −30 to 60°CTemperature changerate
−10°C/h
Humidity Operating 8 to 80%Non-operating 8 to 90%Maximum wet bulbtemperature
29°C(non-condensing)
Vibration Operating 0.25G or lessNon-operating 0.5G or lessTransporting (packed) 0.5G or less
Impact Operating 2G or less 10ms half-since wave.Non-operating 5G or lessTransporting (packed) 8G or less
Angle at which the equipment will turnover
15 degrees or more. Measured when installed withleveling bolts.
Atmosphere No corrosive gas and salty air must be found.Acoustic noise 55dB or less 57dB or
less55dBor less
60dBor less
Measured with the A scale, andat the position one meter awayfrom the front end of the unit andone meter high.
MTBF More than 50,000 hours are expected. The case of the minimumconstruction.
MTBDA
(MTBF of the drives)2
n(n−1) × row numbers × MTTR
More than about 20 million.
Mean Time Between DataAvailability
Drop in package (JIS Z 0200-1994) No abnormality must be free drop level IV. Noabnorm-alitymust befound atdroplevel IV(one endisdroppedwhileanotherend issupport-ed).
Radio frequency radiation Conforms to FCC Part 15B Class A.Instantaneous power failure 10ms (100% dip)
Type
Item
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0140REV.5 Jul.1997
2.3 Handling
This equipment is sensitive against vibration, shock, and dust. Special care must be given to handling so that
static electricity or an unreasonable force will not be applied to the subsystem.
2.3.1 Packing
Apply moisture-proof packing to DF350.
(1) For packing, use the inner, outer, and shock absorbing materials used for transportation from the
manufacturing factory or use the shock absorbing structure that prevents direct shock.
(2) Mark the top and bottom clearly on the outer surface of the packing box so that the box will not be put
upside down. Also, mark the precaution for careful handling.
2.3.2 Transportation
During transportation, do not let shock and vibration higher than specified values be given to the equipment.
2.3.3 Storage
For storage, apply moisture-proof packing.
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0150REV.5 Mar.1997 Jul.1997
2.4 Battery Storage
Following fully-closed lead acid batteries are used:
desktop type (DK/DKH): Voltage 6.0 V, capacitance 1.2 Ah,
rack mount RKH type: voltage 6.0 V, capacitance 6 Ah,
mini tower/cabinet/rack mount RKWH type: voltage 6.0 V, capacitance 10 Ah
The fully-closed lead acid battery is a valuable resource that can be recycled. The three-arrow mark shown
below indicates that the fully-closed lead acid battery is a component that can be recycled. A seal of this mark is
affixed on the sheet metal holder of the battery.
Upon replacement of the battery or scrapping of the subsystem, please cooperate in recycling of the fully-closed
lead acid battery. Insulate the battery connection cords with insulating tapes and bring the battery to a dealer
cooperating in recycling.
Pb
For safety upon disposal/storage of the battery, the following must be strictly observed:
CAUTION!
The battery contains a poisonous substance. An electric shock may be caused by inappropriate handling.
Be sure to follow the instructions below.
(1) Do not disassemble or remake the battery.
(2) Do not deform the battery.
(3) Do not connect (+) pole to (-) pole with metallic article such as a steel wire.
(4) Do not reverse (+) and (-) poles.
(5) Do not peel off the covering tube.
(6) Do not connect the battery directly to the outlet.
(7) Do not connect the battery to anything other than this subsystem for
charging/discharging.
(8) Do not leave the battery at a hot place. Store the battery in a dark, cool place.
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0160REV.7 Mar.1997 Jul.1997 Dec.1997 Feb.1998
3. Appearance
3.1 Appearance of DF350 subsystem
Figure 3.1.1, 3.1.2 and 3.1.3 shows the appearance of the DF350 subsystem.
UNIT : mm
Front
150
350
400
Desktop Type (DK)
Front
465230
409
Mini tower Type
460230
57
Weight : about 4kg
Pedestal for the Mini tower
Desktop Type (DKH)(Stand alone)
Front Front
Desktop Type (DKH)(Rack mount)
483420
170
170
420
435
Name ColorDesktop Mini tower
(DK) (DKH)Front cover Sandstone light
(10Y 7.3/0.4)Limestone light(10YR 7.3/0.2)
Sandstone light(10Y 7.3/0.4)
Side cover Main body Sandstone light
(10Y 7.3/0.4)Pedestal for the
Mini tower Sandstone dark
(10Y 5.3/0.4)
Figure 3.1.1 Appearance of DF350 Subsystem (Desktop(DK/DKH) and Mini tower type)
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0170REV.5 Mar.1997 Jul.1997
600250
700
300
UNIT : mm
Front
Front
656
263484
Cabinet Type
Rack mount (RKH) Type
Front
Front bezel
Rack mount (RKWH) Type
632
442
480
Name ColorCabinet Rack mount (RKH) Rack mount (RKWH)
Front cover Sandstone light(10Y 7.3/0.4)
Side cover Silver GrayMain body
Anti-turnover skirt Sandstone dark(10Y 5.3/0.4)
− −
Figure 3.1.2 Appearance of DF350 Subsystem (Cabinet and Rack Mount Types)
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0180REV.5 Mar.1997 Jul.1997
UNIT : mm
1,790
800
850
700
800
1,980
U1 Rack (RKH) U2 Rack (RKWH)
External color : Sandstone light (10Y 7.3/0.4)
Figure 3.1.3 Appearance of DF350 Subsystem (U1 Rack and U2 Rack)
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0190REV.6 Mar.1997 Jul.1997 Dec.1997
3.2 Maintenance Area
Figure 3.2.1, 3.2.2 and 3.2.3 shows the maintenance area of the DF350 subsystem.
CAUTION!
Do not place it on the unstable place, on the shaky table, or the inclined place, etc.Dropping or a fall of it may cause an injury.
200 200
300
420
400
170
(c) Desktop Type (DKH)Maintenance area(stand alone)
200 150 200
300
420
400
(a) Desktop Type (DK)Maintenance area
150
300
420
400
(b) Desktop Type (DK)setting area
(d) Desktop Type (DKH)Setting area(stand alone)
170
300
420
400
(e) Desktop Type (DKH)Maintenance area(rack mount)
483
300
420
400
Mini tower Type
230
300
465
400
300
: Outer dimensions of subsystem
: Maintenance area
: Front (operaton panel side)
: Setting area
UNIT : mm
Figure 3.2.1 Maintenance Area of DF350 Subsystem (Desktop(DK/DKH) and Mini tower Types)
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0200REV.5 Mar.1997 Jul.1997
137 86
UNIT : mm
300
400
416542
600
10744
300211
300
49
50
484
500
656
400
Cabinet T ype
Rack mount (RKH) Type
400
632
500
480
Rack mount (RKWH) Type
: Outer dimensions of subsystem
: Maintenance area
: Front (operaton panel side)
: Leveling bolt
: Caster
Figure 3.2.2 Maintenance Area of DF350 Subsystem (Cabinet and Rack Mount Type)
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0210REV.5 Mar.1997 Jul.1997
1,000
850
1,000
1,200
200800
200 55
91
91
7030
123.5
30
123.5
1,000
800
1,000
1,100
200 200700 80
145
85
150
106101
4646
For U1 rack (RKH) For U2 rack (RKWH)
: Outer dimensions of subsystem
: Maintenance area
: Front (operaton panel side)
: Leveling bolt
: Caster
Figure 3.2.3 Maintenance Area of DF350 Subsystem (U1 Rack and U2 Rack)
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0220REV.6 Mar.1997 Jul.1997 Dec.1997
4. System Configuration
4.1 Desktop Type (DK)
The desktop type (DK) configuration and the list of desktop type component models are shown below.
4.1.1 Desktop type (DK) configuration
The basic configuration of the DF350 desktop type (DK) disk array subsystem consists of rows of disk drives
(one row contains 4 data disk drives and 1 parity data disk drive (totally 5 disk drives)) and the controller used to
control these disk drives. The desktop type has the power supply, redundant power supply, fan, and cache
memory 16MB (8MB ×2) as the standard components. (See Figure 4.1.1.)
Host device
I/F ADAPTER ASSY(*2)
RS232C(for maintenance)CTL ASSY
MPU LAN ASSYDF-F350-G1D1 (*3)
SCSICTL
SVP
PANEL ASSY
89 - 127V ACor
178 - 254V AC(single phase)
IN BOXASSY
AC/DC power supply
DF-F350-B2D
DF-F350-B2D
BatteryASSY
FDD
CACHE ASSY16MB(8MB×2)
(*1)
D-CTL
FANASSY SCSI CTL
LAN(for maintenance)
DF-F350-G1D1/G2D1
install
*1 CACHE ASSYDF-F350-C8E : 8MB×2A pair of cache memories of the same model make one set. (standard components)
*2 I/F ADAPTER ASSYDF-F350-DDUDS : Wide differential, 68-pin, with locking screwsDF-F350-DDUSS : Wide single-ended, 68-pin, with locking screws
*3 LAN ASSY is optional.
Figure 4.1.1 Desktop Type (DK) Configuration
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0230REV.8 Mar.1997 Jul.1997 Dec.1997 May.1998 Oct.1998
4.1.2 List of desktop type (DK) component models
(1) Essential components
Table 4.1.1 List of Desktop Type (DK) Component Models (Essential)Category Model Component name Specification Selection
Basic cabinet DF350-DK Desktop type (DK)basic cabinet
Frame, Cover, CTL ASSY, PANEL ASSY,FDD ASSY, Battery ASSY, Fan ASSY, In BoxASSY, power cable,cache memory (8MB×2),Disk drive power supply, and Redundantpower supply
Essential
Indivi-idualunit
DF-F350-A2E2
One 3.5-inch diskdrive (2.0GB)
3.5-inch disk drive (2.0GB) installed in the 1-inch height canister
(*2)
DF-F350-A2E4
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
DF-F350-A3E4 (*3)
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
DF-F350-A2E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
Rowconfi-gurat-
DF-F350-E2E2
Five 3.5-inch diskdrives (2.0GB)
Five 3.5-inch disk drives (2.0GB) installed inthe 1-inch height canister, configuraing a row• RAID5(4D) : 8.2GB
ion DF-F350-E2E4
Five 3.5-inch diskdrives (4.1GB)
Five 3.5-inch disk drives (4.1GB) installed inthe 1-inch height canister, configuring a row• RAID5(4D) : 16.6GB
DF-F350-E3E4(*3)
Five 3.5-inch diskdrives (4.1GB)
Five 3.5-inch disk drives (4.1GB) installed inthe 1-inch height canister, configuring a row• RAID5(4D) : 16.6GB
DF-F350-E2E8
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 43.5GB• RAID5(4D) : 34.8GB
Interface DF-F350-DDUDS
Desktop type interfaceW/D (68PS)
Desktop type wide differential, 68-pin, pin-type, screw locked (provided with a terminator)
Select either of themodels shown on theleft depending on the
DF-F350-DDUSS
Desktop type interfaceW/S (68PS)
Desktop type wide single-ended, 68-pin, pin-type, screw locked (provided with a terminator)
interface to beconnected.
*1 Install one of the disk drives with capacities of 2.0GB, 4.1GB, or 8.7GB according to the capacity ofthe subsystem.
*2 RAID0 : Select the individual disk units (minimum two units) in units of a disk unit.RAID1 : Select the individual disk units (minimum two units) in units of two disk unit.RAID5
(4D+1P) : Select (a) low(s) of disk drives in units of a row.(3D+1P) : Select the individual disk units in units of four disk units.(2D+1P) : Select the individual disk units in units of three disk units.
RAIDA :Select the individual disk units in units of four disk units.*3 It is necessary to use it with the Micro_Disk Ver.0307 or later.
Diskdrive(*1)
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0240REV.8 Mar.1997 Jul.1997 Dec.1997 May.1998 Oct.1998
(2) Optional components
Table 4.1.2 List of Desktop Type (DK) Component Models (Optional)Category Model Component name Specification Selection
Additional diskdrive
DF-F350-A2E2
3.5-inch disk drive See “individual-unit disk drive” as the essentialcomponent.
• See “disk drive” asthe essentialcomponent.
DF-F350-A2E4
• Selectable if moredrives can bemounted in the
DF-F350-A3E4
RAID0 or RAID1configuration.
DF-F350-A2E8
LAN board(*1)
DF-F350-G1D1
LAN board for desktoptype
LAN board for desktop type
DF-F350-G2D1
SNMP-compatibleLAN board for desktoptype
SNMP-compatible remote maintenance LANboard for desktop type
PC formaintenance
DF-F350-R1 PC for maintenance PC with the maintenance tool installed RS232C cableseparately required forconnecting the diskarray subsystem.
*1 Mount either model LAN board only.
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0242REV.0 Dec.1997
4.2 Desktop Type (DKH)
The desktop type (DKH) configuration and the list of desktop type component models are shown below.
4.2.1 Desktop type (DKH) configuration
The basic configuration of the DF350 desktop type (DKH) disk array subsystem consists of rows of disk drives
(one row contains 4 data disk drives, 1 parity data disk drive and 1 spare disk (totally 6 disk drives)) and the
controller used to control these disk drives. (See Figure 4.2.1.)
89 - 127V ACor
178 - 254V AC(single phase)
Host device
I/F ADAPTER ASSY(*2)
RS232C(for maintenance)CTL ASSY
MPU LAN ASSYDF-F350-G1D1 (*3)
SCSICTL
SVP
PANEL ASSY
Power supply
DF-F350-B1H
BatteryASSY
FDD
CACHE ASSY(*1, *3)
D-CTL
SCSI CTL
DF-F350-B1H (*3)
Spare disk (*3)
LAN(for maintenance)
DF-F350-G1D1/G2D1
install
*1 CACHE ASSYDF-F350-C8E : 8MBDF-F350-C32E : 32MBDF-F350-C128E : 128MBA pair of cache memories of the same model make one set.
*2 I/F ADAPTER ASSYDF-F350-DHUDS : Wide differential, 68-pin, screw lockedDF-F350-DHUSS : Wide single-ended, 68-pin, screw locked
*3 The redundant power supply, spare disk drive, CACHE ASSY and LAN ASSY are optional.
Figure 4.2.1 Desktop Type (DKH) Configuration
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0244REV.2 Dec.1997 May.1998 Oct.1998
4.2.2 List of desktop type (DKH) component models
(1) Essential Components
Table 4.2.1 List of Desktop Type (DKH) Component Models (Essential)Category Model Component name Specification Selection
Basic cabinet DF350-DKH Desktop type (DKH)basic cabinet
Frame, Cover, CTL ASSY, SVP ASSY, FDDASSY, Battery ASSY, PANEL ASSY, FANBox ASSY, and pwer calbe.
Essential
DF-F350-A2E2
One 3.5-inch diskdrive (2.0GB)
3.5-inch disk drive (2.0GB) installed in the 1-inch height canister
(*3)
DF-F350-A2E4
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
Indivi-dual
DF-F350-A3E4 (*4)
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
unit DF-F350-A2E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
DF-F350-A1E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the halfinch height canister
DF-F350-A1E18
One 3.5-inch diskdrive (17.8GB)
3.5-inch disk drive (17.8GB) installed in thehalf inch height canister
Diskdrive(*1)
DF-F350-E2E2
Five 3.5-inch diskdrives (2.0GB)
Five 3.5-inch disk drives (2.0GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 10.3GB• RAID5(4D) : 8.2GB
DF-F350-E2E4
Five 3.5-inch diskdrives (4.1GB)
Five 3.5-inch disk drives (4.1GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 20.8GB• RAID5(4D) : 16.6GB
Rowconfi-gurat-
ion
DF-F350-E3E4(*4)
Five 3.5-inch diskdrives (4.1GB)
Five 3.5-inch disk drives (4.1GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 20.8GB• RAID5(4D) : 16.6GB
DF-F350-E2E8
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 43.5GB• RAID5(4D) : 34.8GB
DF-F350-E1E8
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe half inch hight canister, configuring a row• RAID0 : 43.5GB• RAID5(4D) : 34.8GB
DF-F350-E1E18
Five 3.5-inch diskdrives (17.8GB)
Five 3.5-inch disk drives (17.8GB) installed inthe half inch hight canister, configuring a row• RAID0 : 89.0GB• RAID5(4D) : 71.2GB
Cache memory(*2)
DF-F350-C8E
Cache memory(8MB)
Cache memory (8MB) (8MB-board × 1) Select the cachememory to be mountedon CTL
DF-F350-C32E
Cache memory(32MB)
Cache memory (32MB) (32MB-board × 1) ASSY in unit of 2board (at least 2boards).
DF-F350-C128E
Cache memory(128MB)
Cache memory (128MB) (128MB-board × 1)
Interface DF-F350-DHUDS
Mini tower/cabinettype interface W/D(68PS)
Mini tower/cabinet wide single-ended, 68-pin,pin-type, screw locked (provided with aterminator.)
Select either of themodels shown on theleft depending on the
DF-F350-DHUSS
Mini tower/cabinetinterface W/S(68PS)
Mini tower/cabinet wide single-ended, 68-pin,pin-type, screw lcked (provided with aterminator.)
interface to beconnected.
*1 Install one of the disk drives with capacities of 2.0GB, 4.1GB, 8.7GB, or 17.8GB according to thecapacity of the subsystem.
*2 Mount either model of cache memory only.*3 RAID0 : Select the individual disk units (minimum two units) in units of a disk unit.
RAID1 : Select the individual disk units (minimum two units) in units of two disk unit.RAID5
(4D+1P) : Select (a) low(s) of disk drives in units of a row.(3D+1P) : Select the individual disk units in units of four disk units.(2D+1P) : Select the individual disk units in units of three disk units.
RAIDA :Select the individual disk units in units of four disk units.*4 It is necessary to use it with the Micro_Disk Ver.0307 or later.
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0246REV.2 Dec.1997 May.1998 Oct.1998
(2) Optional components
Table 4.2.2 List of Desktop Type (DKH) Component Models (Optional)Category Model Component name Specification Selection
Spare diskdrive
DF-F350-A2E2
One 3.5-inch diskdrive (2.0GB)
3.5-inch disk drive (2.0GB) installed in the 1-inch height canister
• One spare disk isrequired for the entiresubsyste.
DF-F350-A2E4
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
• Power supply for thespare disk drive is notrequired.
DF-F350-A3E4
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
• Mount a disk drivewhose capacity isequivalent to the
DF-F350-A2E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
maximum capacity ofthe disk drivesmounted.
DF-F350-A1E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the halfinch height canister
DF-F350-A1E18
One 3.5-inch diskdrive (17.8GB)
3.5-inch disk drive (17.8GB) installed in thehalf inch height canister
Redundant diskpower supply
DF-F350-B1H
Redundant powersupply
Disk drive power supply Power supply can beduplicated.
Cache memory DF-F350-C8E
Cache memory See “cache memory” as the essentialcomponent.
See “cache memory” asthe essentialcomponent.
DF-F350-C32E
Up to 8 cache memoriescan be mounted.
DF-F350-C128E
Additional diskdrive
DF-F350-A2E2
3.5-inch disk drive See “individual-unit disk drive” as the essentialcomponent.
• See “disk drive” as theessential component.
DF-F350-A2E4
• Selectable if moredrives can bemounted
DF-F350-A3E4
in the RAID0 orRAID1 configuration.
DF-F350-A2E8
DF-F350-A1E8
DF-F350-A1E18
LAN board(*1)
DF-F350-G1D1
LAN board for minitower, type etc.
LAN board for mini tower, cabinet, and rackmount types
DF-F350-G2D1
SNMP-compatibleLAN board for minitower type, etc.
SNMP-compatible remote maintenance LANboard for mini tower, cabinet, and rack mounttypes
PC formaintenance
DF-F350-R1 PC for maintenance PC with the maintenance tool installed RS232C cableseparately required forconnecting the diskarray subsystem.
*1 Mount either model of LAN board only.
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0250REV.6 Mar.1997 Jul.1997 Dec.1997
4.3 Mini Tower Type
The mini tower type configuration and the list of mini tower type component models are shown below.
4.3.1 Mini tower type configuration
The basic configuration of the DF350 mini tower type disk array subsystem consists of rows of disk drives (one
row contains 4 data disk drives, 1 parity data disk drive, and 1 optional spare disk drive (totally 6 disk drives))
and the controller used to control these disk drives. (See Figure 4.3.1.)
89 - 127V ACor
178 - 254V AC(single phase)
DF-F350-B2M(*3)
DF-F350-B2M
Host device
(*3)
CTL ASSY DF-F350-F1MCF
LAN ASSYDF-F350-G1M1 (*3)
SCSI CTL
SVP ASSY
INBOXASSY
AC/DC power supply
BatteryASSY
FDD
D-CTL
FANASSY SCSI CTL
I/F ADAPTER ASSY(*2)
Spare disk (*3)
CTL ASSY DF-F350-F2MCF (*3)
RS232C(for maintenance)
LAN(for maintenance)
DF-F350-G1M1/G2M1
install
MPU
CACHE ASSY(*1, *3)
*1 CACHE ASSYDF-F350-C8E : 8MBDF-F350-C32E : 32MBDF-F350-C128E : 128MBA pair of cache memories of the same model make one set. Up to four sets can be mounted. (Mixtureof different sets is allowed.)
*2 I/F ADAPTER ASSYDF-F350-DMUDS : Wide differential, 68-pin, screw lockedDF-F350-DMUSS : Wide single-ended, 68-pin, screw locked
*3 The redundant AC/DC power supply, spare disk drive, LAN ASSY, redundant CTL ASSY, CAHCEASSY, and I/F ADAPTER ASSY for redundant CTL ASSY are optional.
Figure 4.3.1 Mini Tower Type Configuration
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0260REV.9 Mar.1997 Jul.1997 Dec.1997 Feb.1998 May.1998 Oct.1998
4.3.2 List of mini tower type component models
(1) Essential Components
Table 4.3.1 List of Mini Tower Type Component Models (Essential)Category Model Component name Specification Selection
Basic cabinet DF350-MK Mini tower type basiccabinet
Frame, Cover, CTL ASSY, SVP ASSY, FDDASSY, Battery ASSY, Fan ASSY, In BoxASSY, and power calbe.
Essential
DF-F350-A2E2
One 3.5-inch diskdrive (2.0GB)
3.5-inch disk drive (2.0GB) installed in the 1-inch height canister
(*2)
DF-F350-A3E4 (*4)
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
DF-F350-A2E4
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
DF-F350-A2E4A
(For AS/400)
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
DF-F350-A2E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
DF-F350-A2E8A
(For AS/400)
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
DF-F350-A1E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the halfinch height canister
DF-F350-A1E8A
(For AS/400)
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the helfinch height canister
DF-F350-A1E18
One 3.5-inch diskdrive (17.8GB)
3.5-inch disk drive (17.8GB) installed in thehalf inch height canister
DF-F350-E2E2
Five 3.5-inch diskdrives (2.0GB)
Five 3.5-inch disk drives (2.0GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 10.3GB• RAID5(4D) : 8.2GB
DF-F350-E3E4(*4)
Five 3.5-inch diskdrives (4.1GB)
Five 3.5-inch disk drives (4.1GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 20.8GB• RAID5(4D) : 16.6GB
DF-F350-E2E4
Five 3.5-inch diskdrives (4.1GB)
Five 3.5-inch disk drives (4.1GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 20.8GB• RAID5(4D) : 16.6GB
DF-F350-E2E4A
(For AS/400)
Five 3.5-inch diskdrives (4.1GB)
Five 3.5-inch disk drives (4.1GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 20.8GB• RAID5(4D) : 16.6GB
Rowconfi-gurat-
ion
DF-F350-E2E8
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 43.5GB• RAID5(4D) : 34.8GB
DF-F350-E2E8A
(For AS/400)
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 43.5GB• RAID5(4D) : 34.8GB
DF-F350-E1E8
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe half inch hight canister, configuring a row• RAID0 : 43.5GB• RAID5(4D) : 34.8GB
DF-F350-E1E8A
(For AS/400)
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe half inch hight canister, configuring a row• RAID0 : 43.5GB• RAID5(4D) : 34.8GB
DF-F350-E1E18
Five 3.5-inch diskdrives (17.8GB)
Five 3.5-inch disk drives (17.8GB) installed inthe half inch hight canister, configuring a row• RAID0 : 89.0GB• RAID5(4D) : 71.2GB
Indiv-dualunit
Diskdrive(*1)
DF350 K6601299-
Copyright © 1998, Hitachi, Ltd.
SPEC0265REV.1 May.1998 Oct.1998
Table 4.3.1 List of Mini Tower Type Component Models (Essential)Category Model Component name Specification SelectionDisk drive
power supplyDF-F350-
B2MPower supply formini tower type, etc.
Disk drive power supply for mini tower type,etc.
Cache memory(*3)
DF-F350-C8E
Cache memory(8MB)
Cache memory (8MB) (8MB-board × 1) Select the cachememory to be mountedon CTL
DF-F350-C32E
Cache memory(32MB)
Cache memory (32MB) (32MB-board × 1) ASSY in unit of 2 board(at least 2 boards).
DF-F350-C128E
Cache memory(128MB)
Cache memory (128MB) (128MB-board × 1)
Interface DF-F350-DMUDS
Mini tower/cabinettype interface W/D(68PS)
Mini tower/cabinet wide single-ended, 68-pin,pin-type, screw locked (provided with aterminator.)
Select either of themodels shown on theleft depending on the
DF-F350-DMUSS
Mini tower/cabinetinterface W/S(68PS)
Mini tower/cabinet wide single-ended, 68-pin,pin-type, screw lcked (provided with aterminator.)
interface to beconnected.
*1 Install one of the disk drives with capacities of 2.0GB, 4.1GB, 8.7GB, or 17.8GB according to thecapacity of the subsystem.
*2 RAID0 : Select the individual disk units (minimum two units) in units of a disk unit.RAID1 : Select the individual disk units (minimum two units) in units of two disk unit.RAID5
(4D+1P) : Select (a) low(s) of disk drives in units of a row.(3D+1P) : Select the individual disk units in units of four disk units.(2D+1P) : Select the individual disk units in units of three disk units.
RAIDA :Select the individual disk units in units of four disk units.*3 Mount either model of cache memory only.*4 It is necessary to use it with the Micro_Disk Ver.0307 or later.
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0270REV.8 Mar.1997 Jul.1997 Feb.1998 May.1998 Oct.1998
(2) Optional components
Table 4.3.2 List of Mini Tower Type Component Models (Optional)Category Model Component name Specification Selection
Spare diskdrive
DF-F350-A2E2
One 3.5-inch diskdrive (2.0GB)
3.5-inch disk drive (2.0GB) installed in the 1-inch height canister
• One spare disk isrequired for the entire
DF-F350-A3E4
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
subsyste.• Power supply for the
DF-F350-A2E4
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
spare disk drive is notrequired.
DF-F350-A2E4A
(For AS/400)
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
• Mount a disk drivewhose capacity is
DF-F350-A2E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
equivalent to themaximum capacity ofthe disk drives
DF-F350-A2E8A
(For AS/400)
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
mounted.
DF-F350-A1E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the halfinch height canister
DF-F350-A1E8A
(For AS/400)
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the halfinch height canister
DF-F350-A1E18
One 3.5-inch diskdrive (17.8GB)
3.5-inch disk drive (17.8GB) installed in thehalf inch height canister
Redundant diskpower supply
DF-F350-B2M
Redundant powersupply
See “disk drive power supply” as the essentialcomponent.
Power supply can beduplicated.
Cache memory DF-F350-C8E
Cache memory See “cache memory” as the essentialcomponent.
See “cache memory” asthe essentialcomponent.
DF-F350-C32E
Up to 8 cache memoriescan be mounted.
DF-F350-C128E
Interface DF-F350-DMUDS
Interface See “interface” as the essential component. Add the interface toduplicate the controller.
DF-F350-DMUSS
Additional diskdrive
DF-F350-A2E2
3.5-inch disk drive See “individual-unit disk drive” as the essentialcomponent.
• See “disk drive” as theessential component.
DF-F350-A3E4
• Selectable if moredrives can bemounted
DF-F350-A2E4
in the RAID0 orRAID1 configuration.
DF-F350-A2E4A
(For AS/400)DF-F350-
A2E8DF-F350-
A2E8A(For AS/400)
DF-F350-A1E8
DF-F350-A1E8A
(For AS/400)DF-F350-
A1E18LAN board DF-F350-
G1M1LAN board for minitower, type etc.
LAN board for mini tower, cabinet, and rackmount types
DF-F350-G2M1
SNMP-compatibleLAN board for minitower type, etc.
SNMP-compatible remote maintenance LANboard for mini tower, cabinet, and rack mounttypes
DF350 K6601299-
Copyright © 1998, Hitachi, Ltd.
SPEC0275REV.0 Oct.1998
Table 4.3.2 List of Mini Tower Type Component Models (Optional)Category Model Component name Specification Selection
Array controller DF-F350-F2MCF
Controller (aprogram product) forduplicating thesystem.
Array controller for duplicating the system; aprogram product for mini tower, cabinet, andrack mount (RKH) types.
• Controller can beduplicated.
• Mount the cachememory whosecapacity is equivalentto that mounted onthe basic controller.
PC formaintenance
DF-F350-R1 PC for maintenance PC with the maintenance tool installed RS232C cableseparately required forconnecting the diskarray subsystem.
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0280REV.6 Mar.1997 Jul.1997 Dec.1997
4.4 Cabinet Type
The cabinet type configuration and the list of cabinet type component models are shown below.
4.4.1 Cabinet type configuration
The basic configuration of the DF350cabinet type disk array subsystem consists of up to 4 rows (i.e. 1 basic row
plus 3 additional rows) of disk drives (one row contains 4 data disk drives and 1 parity data disk drive (totally 6
disk drives)), an optional spare disk (i.e. up to 21 disk drives in total), and the controller used to control these
disk drives. (See Figure 4.4.1.)
89 - 127V ACor
178 - 254V AC(single phase)
Host device
(*3)
CTL ASSY DF-F350-F1MCF
LAN ASSYDF-F350-G1M1 (*3)
SCSI CTL
AC/DC power supply
BatteryASSY
FDD
D-CTL
FANASSY SCSI CTL
I/F ADAPTER ASSY(*2)
Spare disk (*3)
CTL ASSY DF-F350-F2MCF (*3)
RS232C(for maintenance)
SVPASSY
Data disk drives
Up to 3 row s of additionaldata disk drives
LAN(for maintenance)
DF-F350-G1M1/G2M1
install
MPU
CACHE ASSY(*1, *3)
INBOXASSY
DF-F350-B2M
DF-F350-B2M(*3)
DF-F350-B2M(*3)
DF-F350-B2M(*3)
DF-F350-B2M(*3)
*1 CACHE ASSYDF-F350-C8E : 8MBDF-F350-C32E : 32MBDF-F350-C128E : 128MBA pair of cache memories of the same model make one set. Up to four sets can be mounted. (Mixtureof different sets is allowed.)
*2 I/F ADAPTER ASSYDF-F350-DMUDS : Wide differential, 68-pin, screw lockedDF-F350-DMUSS : Wide single-ended, 68-pin, screw locked
*3 The redundant AC/DC power supply, spare disk drive, LAN ASSY, redundant CTL ASSY, CACHEASSY, and I/F ADAPTER ASSY for redundant CTL ASSY are optional.
Figure 4.4.1 Cabinet Type Configuration
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0290REV.8 Mar.1997 Jul.1997 Dec.1997 Feb.1998 Oct.1998
4.4.2 List of cabinet type component models
(1) Essential Components
Table 4.4.1 List of Cabinet Type Component Models (Essential)Category Model Component name Specification Selection
Basic cabinet DF350-CK Cabinet type basiccabinet
Frame, Cover, CTL ASSY, SVP ASSY, FDDASSY, Battery ASSY, Fan ASSY, In BoxASSY, and power cable
Essential
DF-F350-A2E2
One 3.5-inch diskdrive (2.0GB)
3.5-inch disk drive (2.0GB) installed in the 1-inch height canister
(*3)
DF-F350-A3E4 (*5)
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
DF-F350-A2E4
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
DF-F350-A2E4A
(For AS/400)
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
DF-F350-A2E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
DF-F350-A2E8A
(For AS/400)
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
DF-F350-A1E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the halfinch height canister
DF-F350-A1E8A
(For AS/400)
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the halfinch height canister
DF-F350-A1E18
One 3.5-inch diskdrive (17.8GB)
3.5-inch disk drive (17.8GB) installed in thehalf inch height canister
DF-F350-E2E2
Five 3.5-inch diskdrives (2.0GB)
Five 3.5-inch disk drives (2.0GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 10.3GB• RAID5(4D) : 8.2GB
DF-F350-E3E4(*5)
Five 3.5-inch diskdrives (4.1GB)
Five 3.5-inch disk drives (4.1GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 20.8GB• RAID5(4D) : 16.6GB
DF-F350-E2E4
Five 3.5-inch diskdrives (4.1GB)
Five 3.5-inch disk drives (4.1GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 20.8GB• RAID5(4D) : 16.6GB
DF-F350-E2E4A
(For AS/400)
Five 3.5-inch diskdrives (4.1GB)
Five 3.5-inch disk drives (4.1GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 20.8GB• RAID5(4D) : 16.6GB
DF-F350-E2E8
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 43.5GB• RAID5(4D) : 34.8GB
Rowconfi-gurat-
ion
DF-F350-E2E8A
(For AS/400)
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 43.5GB• RAID5(4D) : 34.8GB
DF-F350-E1E8
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe half inch height canister, configuring a row• RAID0 : 43.5GB• RAID5(4D) : 34.8GB
DF-F350-E1E8A
(For AS/400)
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe half inch height canister, configuring a row• RAID0 : 43.5GB• RAID5(4D) : 34.8GB
DF-F350-E1E18
Five 3.5-inch diskdrives (17.8GB)
Five 3.5-inch disk drives (17.8GB) installed inthe half inch height canister, configuring a row• RAID0 : 89.0GB• RAID5(4D) : 71.2GB
Indivi-dualunit
DF350 K6601299-
Copyright ©1998, Hitachi, Ltd.
SPEC0295REV.1 May.1998 Oct.1998
Table 4.4.1 List of Cabinet Type Component Models (Essential)Category Model Component name Specification SelectionDisk drive
power supplyDF-F350-
B2MPower supply formini tower type, etc.
Disk drive power supply for mini tower type,etc.
(*2)
Cache memory(*4)
DF-F350-C8E
Cache memory(8MB)
Cache memory (8MB) (8MB-board × 1) Select the cachememory to be mountedon CTL
DF-F350-C32E
Cache memory(32MB)
Cache memory (32MB) (32MB-board × 1) ASSY in unit of 2boards. (at least 2boards).
DF-F350-C128E
Cache memory(128MB)
Cache memory (128MB) (128MB-board × 1)
Interface DF-F350-DMUDS
Mini tower/cabinettype interface W/D(68PS)
Mini tower/cabinet type wide differential, 68-pin, pin-type, screw-locked (provided with aterminator)
Select either of themodels shown on theleft depending on the
DF-F350-DMUSS
Mini tower/cabinetinterface W/S(68PS)
Mini tower/cabinet wide single-ended, 68-pin,pin-type, screw-locked (provided with aterminator)
interface to beconnected.
*1 Install one of the disk drives with capacities of 2.0GB, 4.1GB, 8.7GB, or 17.8GB according to the capacity of thesubsystem.
*2 One power supply must be provided per one row of disk drives.
*3 RAID0 : Select the individual disk units (minimum two units) in units of a disk unit.
RAID1 : Select the individual disk units (minimum two units) in units of two disk unit.
RAID5
(4D+1P) : Select (a) low(s) of disk drives in units of a row.
(3D+1P) : Select the individual disk units in units of four disk units.
(2D+1P) : Select the individual disk units in units of three disk units.
RAIDA : Select the individual disk units in units of four disk units.*4 Mount either model of cache memory only.*5 It is necessary to use it with the Micro_Disk Ver.0307 or later.
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0300REV.8 Mar.1997 Jul.1997 Feb.1998 May.1998 Oct.1998
(2) Optional components
Table 4.4.2 List of Cabinet Type Component Models (Optional)Category Model Component name Specification Selection
Spare diskdrive
DF-F350-A2E2
One 3.5-inch dickdrive (2.0GB)
3.5-inch disk drive (2.0GB) installed in the 1-inch height canister
• One spare disk isrequired for the entire
DF-F350-A3E4
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
subsystem.• Power supply for
DF-F350-A2E4
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
the spare disk drive isnot required.
DF-F350-A2E4A
(For AS/400)
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
• Mount a disk drivewhose capacity is
DF-F350-A2E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
equivalent to themaximum capacity of
DF-F350-A2E8A
(For AS/400)
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
the disk drivesmounted.
DF-F350-A1E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the halfinch height canister
DF-F350-A1E8A
(For AS/400)
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the halfinch height canister
DF-F350-A1E18
One 3.5-inch diskdrive (17.8GB)
3.5-inch disk drive (17.8GB) installed in thehalf inch height canister
Redundant diskdrive power
DF-F350-B2M
Redundant powersupply
See “disk drive power supply” as the essentialcomponent.
Add one power supplyper five disk drives.
supplyCache memory DF-F350-
C8ECache memory See “cache memory” as the essential
component.See “cache memory” asthe essentialcomponent.
DF-F350-C32E
Up to 8 cache memoriescan be mounted.
DF-F350-C128E
Interface DF-F350-DMUDS
Interface See “interface” as the essential component. Additional disk drive
DF-F350-DMUSS
DF350 K6601299-
Copyright ©1998, Hitachi, Ltd.
SPEC0305REV.1 May.1998 Oct.1998
Table 4.4.2 List of Cabinet Type Component Models (Optional)Category Model Component name Specification Selection
DF-F350-A2E2
3.5-inch disk drive See “Individual-unit disk drive” as the essentialcomponent.
• See “disk drive” as theessential component.
DF-F350-A3E4
• Selectable if moredisk drives can bemounted.
DF-F350-A2E4
DF-F350-A2E4A
(For AS/400)Indivi-dual
DF-F350-A2E8
unit DF-F350-A2E8A
(For AS/400)DF-F350-
A1E8DF-F350-
A1E8A(For AS/400)
Addit-ional
DF-F350-A1E18
diskdrive
DF-F350-E2E2
3.5-inch disk drive See “disk drive” row configuration as theessential component.
DF-F350-E3E4
DF-F350-E2E4
DF-F350-E2E4A
(For AS/400)DF-F350-
E2E8DF-F350-
E2E8A(For AS/400)
DF-F350-E1E8
DF-F350-E1E8A
(For AS/400)DF-F350-
E1E18LAN board DF-F350-
G1M1LAN board for minitower type, etc.
LAN board for mini tower, cabinet, and rackmount types
DF-F350-G2M1
SNMP-compatibleLAN board for minitower type, etc.
SNMP-compatible remote maintenance LANboard for mini tower, cabinet, and rack mounttypes
Array controller DF-F350-F2MCF
Controller (aprogram product) forduplicating thesystem
Array controller for duplicating the system; aprogram product for mini tower, and cabinet,and rack mount (RKH) types
• Controller can beduplicated.
• Mount the cachememory whosecapacity is equivalentto that mounted onthe basic controller.
PC formaintenance
DF-F350-R1 PC for maintenance PC with the maintenance tool installed RS232C cableseparately required forconnecting the diskarray subsystem.
Rowconfi-gurati-on
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0310REV.7 Mar.1997 Jul.1997 Dec.1997 May.1998
4.5 Rack Mount (RKH) Type
The rack mount (RKH) type configuration and the list of rack mount type component models are shown below.
4.5.1 Rack mount (RKH) type configuration
The basic configuration of the DF350-RKH rack mount type disk array subsystem consists of up to 2 rows (i.e. 1
basic row plus 1 optional row) of disk drives (one row contains 4 data disk drives and 1 parity data disk drive
(totally 5 disk drives)), an optional spare disk drive (i.e. up to 11 disk drives in total), and the controller used to
control these disk drives. (See Figure 4.5.1.)
89 - 127V ACor
178 - 254V AC(single phase)
Host device
(*3)
CTL ASSY DF-F350-F1MCF
LAN ASSYDF-F350-G1M1 (*3)
SCSI CTL
AC/DC power supply
BatteryASSY
FDD
D-CTL
FANASSY SCSI CTL
I/F ADAPTER ASSY(*2)
Spare disk (*3)
CTL ASSY DF-F350-F2MCF (*3)
RS232C(for maintenance)
SVPASSY
Data disk drives
Additional data disk drives (*3)
OPPANEL
SVP
LAN(for maintenance)
DF-F350-G1M1/G2M1
install
MPU
CACHE ASSY(*1, *3)
DF-F350-B2M(*3)
DF-F350-B2M/B4M INBOXASSY
DF-F350-B2M(*3)
*1 CACHE ASSYDF-F350-C8E : 8MBDF-F350-C32E : 32MBDF-F350-C128E : 128MBA pair of cache memories of the same model make one set. Up to four sets can be mounted. (Mixtureof different sets is allowed.)
*2 I/F ADAPTER ASSYDF-F350-DRUDS : Differential, 68-pin, screw-locked
DF-F350-DRUSS : Single-ended, 68-pin, screw-locked
*3 The redundant AC/DC power supply, spare disk drive, LAN ASSY, redundant CTL ASSY, CACHEASSY, and I/F ADAPTER ASSY for redundant CTL ASSY are optional.
Figure 4.5.1 Rack Mount (RKH) Type System Configuration
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0320REV.8 Mar.1997 Jul.1997 Dec.1997 May.1998 Oct.1998
4.5.2 List of rack mount (RKH) type component models
(1) Essential Components
Table 4.5.1 List of Rack Mount (RKH) Type Component Models (Essential)Category Model Component name Specification Selection
Basic cabinet DF350-RKH Rack mount type(RKH) basic cabinet
Frame, Cover, CTL ASSY, SVP ASSY, FDDASSY, Battery ASSY, Fan ASSY, In BoxASSY, and power cable
Essential
DF-F350-A2E2
One 3.5-inch diskdrive (2.0GB)
3.5-inch disk drive (2.0GB) installed in the 1-inch height canister
(*3)
DF-F350-A3E4 (*5)
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
DF-F350-A2E4
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
DF-F350-A2E4A
(For AS/400)
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
DF-F350-A2E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
DF-F350-A2E8A
(For AS/400)
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
DF-F350-A1E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the halfinch height canister
DF-F350-A1E8A
(For AS/400)
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the halfinch height canister
DF-F350-A1E18
One 3.5-inch diskdrive (17.8GB)
3.5-inch disk drive (17.8GB) installed in thehalf inch height canister
DF-F350-E2E2
Five 3.5-inch diskdrives (2.0GB)
Five 3.5-inch disk drives (2.0GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 10.3GB• RAID5 : 8.2GB
DF-F350-E3E4(*5)
Five 3.5-inch diskdrives (4.1GB)
Five 3.5-inch disk drives (4.1GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 20.8GB• RAID5 : 16.6GB
DF-F350-E2E4
Five 3.5-inch diskdrives (4.1GB)
Five 3.5-inch disk drives (4.1GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 20.8GB• RAID5 : 16.6GB
DF-F350-E2E4A
(For AS/400)
Five 3.5-inch diskdrives (4.1GB)
Five 3.5-inch disk drives (4.1GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 20.8GB• RAID5 : 16.6GB
Rowconfi-gurati-
on
DF-F350-E2E8
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 43.5GB• RAID5 : 34.8GB
DF-F350-E2E8A
(For AS/400)
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 43.5GB• RAID5 : 34.8GB
DF-F350-E1E8
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe half inch height canister, configuring a row• RAID0 : 43.5GB• RAID5 : 34.8GB
DF-F350-E1E8A
(For AS/400)
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe half inch height canister, configuring a row• RAID0 : 43.5GB• RAID5 : 34.8GB
DF-F350-E1E18
Five 3.5-inch diskdrives (17.8GB)
Five 3.5-inch disk drives (17.8GB) installed inthe half inch height canister, configuring a row• RAID0 : 89.0GB• RAID5 : 71.2GB
Indiv-dualunit
DF350 K6601299-
Copyright ©1998, Hitachi, Ltd.
SPEC0325REV.1 May.1998 Oct.1998
Table 4.5.1 List of Rack Mount (RKH) Type Component Models (Essential)Category Model Component name Specification SelectionDisk drive
power supplyDF-F350-
B2MPower supply formini tower type, etc.
Disk drive power supply for mini tower type,etc.
(*2)
Cache memory(*4)
DF-F350-C8E
Cache memory(8MB)
Cache memory (8MB) (8MB-board × 1) Select the cachememory to be mountedon CTL
DF-F350-C32E
Cache memory(32MB)
Cache memory (32MB) (32MB-board × 1) ASSY in unit of 2 boards(at least 2 boards)
DF-F350-C128E
Cache memory(128MB)
Cache memory (128MB) (128MB-board × 1)
Interface DF-F350-DRUDS
Rack mount (RKH)type interface W/D(68PS)
Rack mount (RKH) type wide differential, 68-pin, pin-type, screw-locked (provided with aterminator)
Essential
DF-F350-DRUSS
Rack mount (RKH)type interface W/S(68PS)
Rack mount (RKH) type wide single-ended,68-pin, pin-type, screw-locked (provided with aterminator)
*1 Install one of the disk drives with capacities of 2.0GB, 4.1GB, 8.7GB, or 17.8GB according to the capacity of thesubsystem.
*2 One power supply must be provided per one row of disk drives.
*3 RAID0 : Select the individual disk units (minimum two units) in units of a disk unit.
RAID1 : Select the individual disk units (minimum two units) in units of two disk unit.
RAID5
(4D+1P) : Select (a) low(s) of disk drives in units of a row.
(3D+1P) : Select the individual disk units in units of four disk units.
(2D+1P) : Select the individual disk units in units of three disk units.
RAIDA : Select the individual disk units in units of four disk units.*4 Mount either model of cache memory only.*5 It is necessary to use it with the Micro_Disk Ver.0307 or later.
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0330REV.8 Mar.1997 Jul.1997 Feb.1998 May.1998 Oct.1998
(2) Optional Components
Table 4.5.2 List of Rack Mount (RKH) Type Component Models (Optional)Category Model Component name Specification Selection
Spare diskdrive
DF-F350-A2E2
One 3.5-inch dickdrive (2.0GB)
3.5-inch disk drive (2.0GB) installed in the 1-inch height canister
• One spare disk isrequired for the entire
DF-F350-A3E4
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
subsystem.• Power supply for the
DF-F350-A2E4
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
spare disk drive is notrequired.
DF-F350-A2E4A
(For AS/400)
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
• Mount a disk drivewhose capacity isequivalent to the
DF-F350-A2E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
maximum capacity ofthe disk drives
DF-F350-A2E8A
(For AS/400)
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
mounted.
DF-F350-A1E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the halfinch height canister
DF-F350-A1E8A
(For AS/400)
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the halfinch height canister
DF-F350-A1E18
One 3.5-inch diskdrive (17.8GB)
3.5-inch disk drive (17.8GB) installed in thehalf inch height canister
Redundant diskdrive power
supply
DF-F350-B2M
Redundant powersupply
See “disk drive power supply” as the essentialcomponent.
Add one power supplyper five disk drives.
Cache memory DF-F350-C8E
Cache memory See “cache memory” as the essentialcomponent.
See “cache memory” asthe essentialcomponent.
DF-F350-C32E
Up to 8 cache memoriescan be mounted.
DF-F350-C128E
Interface DF-F350-DRUDS
Interface See “interface” as the essential component. Additional disk drive
DF-F350-DRUSS
DF350 K6601299-
Copyright ©1998, Hitachi, Ltd.
SPEC0335REV.1 May.1998 Oct.1998
Table 4.5.2 List of Rack Mount (RKH) Type Component Models (Optional)Category Model Component name Specification Selection
DF-F350-A2E2
3.5-inch disk drive See “Individual-unit disk drive” as the essentialcomponent.
• See “disk drive” as theessential component.
DF-F350-A3E4
• Selectable if moredisk drives can bemounted.
DF-F350-A2E4
DF-F350-A2E4A
(For AS/400)DF-F350-
A2E8DF-F350-
A2E8A(For AS/400)
Indivi-dual
DF-F350-A1E8
unit DF-F350-A1E8A
(For AS/400)Addit-ional
DF-F350-A1E18
diskdrive
DF-F350-E2E2
3.5-inch disk drive See “disk drive” row configuration as theessential component.
DF-F350-E3E4
DF-F350-E2E4
DF-F350-E2E4A
(For AS/400)DF-F350-
E2E8DF-F350-
E2E8A(For AS/400)
DF-F350-E1E8
DF-F350-E1E8A
(ForAS/400)DF-F350-
E1E18LAN board DF-F350-
G1M1LAN board for minitower type, etc.
LAN board for mini tower, cabinet, and rackmount types
DF-F350-G2M1
SNMP-compatibleLAN board for minitower type, etc.
SNMP-compatible remote maintenance LANboard for mini tower, cabinet, and rack mounttypes
Array controller DF-F350-F2MCF
Controller (aprogram product) forduplicating thesystem
Array controller for duplicating the system; aprogram product for mini tower, and cabinet,and rack mount (RKH) types
• Controller can beduplicated.
• Mount the cachememory whosecapacity is equivalentto that mounted onthe basic controller.
Rack mountcabinet
DF-F350-U1 Rack for RKH Rack for rack mount type RKH (with AC powercable)Up to six RKHs can be mounted.
PC formaintenance
DF-F350-R1 PC for maintenance PC with the maintenance tool installed RS232C cable separatelyrequired for connectingthe disk array subsystem.
Rowconfi-
guration
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0340REV.6 Mar.1997 Jul.1997 Dec.1997
4.6 Rack Mount (RKWH) Type
The rack mount (RKWH) type configuration and the list of rack mount type component models are shown below.
4.6.1 Rack mount (RKWH) type configuration
The basic configuration of the DF350-RKWH rack mount type disk array subsystem consists of up to 4 rows (i.e.
1 basic row plus 3 optional row) of disk drives (one row contains 4 data disk drives and 1 parity data disk drive
(totally 5 disk drives)), an optional spare disk drive (i.e. up to 21 disk drives in total), and the controller used to
control these disk drives. (See Figure 4.6.1.)
Host device
(*3)
CTL ASSY DF-F350-F1WCF
LAN ASSYDF-F350-G1M1 (*3)
SCSI CTL
178 - 254V AC(single phase)
IN BOXASSY
AC/DC power supply
BatteryASSY
FDD
D-CTL
FANASSY
I/F ADAPTER ASSY(*2)
Spare disk (*3)
CTL ASSY DF-F350-F2WCF (*3)
RS232C(for maintenance)
SVPASSY
Data disk drives
Up to 3 rows of additional datadisk drives
(*3)
IN BOXASSY
178 - 254V AC(single phase)
DF-F350-B1RW
DF-F350-B1RW
DF-F350-B1RW
DF-F350-B1RW
CON_BOARD
PANEL (U2)
LAN(for maintenance)
DF-F350-G1M1/G2M1
install
SCSI CTL
MPU
CACHE ASSY(*1, *3)
*1 CACHE ASSYDF-F350-C8E : 8MBDF-F350-C32E : 32MBDF-F350-C128E : 128MBA pair of cache memories of the same model make one set. Up to four sets can be mounted. (Mixtureof different sets is allowed.)
*2 I/F ADAPTER ASSYDF-F350-DWUDS : Differential, 68-pin, screw-locked
DF-F350-DWUSS : Single ended, 68-pin, screw-locked
*3 The spare disk drive, additional data disk drives, LAN ASSY, redundant CTL ASSY, CACHE ASSY,and I/F ADAPTER ASSY for redundant CTL ASSY are optional.
Figure 4.6.1 Rack Mount (RKWH) Type System Configuration
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0350REV.7 Mar.1997 Jul.1997 Dec.1997 Oct.1998
4.6.2 List of rack mount (RKWH) type component models
(1) Essential Components
Table 4.6.1 List of Rack Mount (RKWH) Type Component Models (Essential)Category Model Component name Specification Selection
Basic cabinet DF350-RKWH
Rack mount type(RKWH)basiccabinet
Frame, Cover, CTL ASSY, SVP ASSY, FDDASSY, Battery ASSY, 3 Fan ASSY, 4 AC/DCPower supplies, 2 In Box ASSYs, and 2 powercables.
Essential
DF-F350-A2E2
One 3.5-inch diskdrive (2.0GB)
3.5-inch disk drive (2.0GB) installed in the 1-inch height canister
(*2)
DF-F350-A3E4 (*4)
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
DF-F350-A2E4
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
DF-F350-A2E4A
(For AS/400)
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
DF-F350-A2E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
DF-F350-A2E8A
(For AS/400)
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
DF-F350-A1E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the halfinch height canister
DF-F350-A1E8A
(For AS/400)
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the halfinch height canister
DF-F350-A1E18
One 3.5-inch diskdrive (17.8GB)
3.5-inch disk drive (17.8GB) installed in thehalf inch height canister
DF-F350-E2E2
Five 3.5-inch diskdrives (2.0GB)
Five 3.5-inch disk drives (2.0GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 10.3GB• RAID5 : 8.2GB
DF-F350-E3E4(*4)
Five 3.5-inch diskdrives (4.1GB)
Five 3.5-inch disk drives (4.1GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 20.8GB• RAID5 : 16.6GB
DF-F350-E2E4
Five 3.5-inch diskdrives (4.1GB)
Five 3.5-inch disk drives (4.1GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 20.8GB• RAID5 : 16.6GB
DF-F350-E2E4A
(For AS/400)
Five 3.5-inch diskdrives (4.1GB)
Five 3.5-inch disk drives (4.1GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 20.8GB• RAID5 : 16.6GB
Rowconfi-gurati-
on
DF-F350-E2E8
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 43.5GB• RAID5 : 34.8GB
DF-F350-E2E8A
(For AS/400)
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe 1-inch height canister, configuring a row• RAID0 : 43.5GB• RAID5 : 34.8GB
DF-F350-E1E8
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe half inch height canister, configuring a row• RAID0 : 43.5GB• RAID5 : 34.8GB
DF-F350-E1E8A
(For AS/400)
Five 3.5-inch diskdrives (8.7GB)
Five 3.5-inch disk drives (8.7GB) installed inthe half inch height canister, configuring a row• RAID0 : 43.5GB• RAID5 : 34.8GB
DF-F350-E1E18
Five 3.5-inch diskdrives (17.8GB)
Five 3.5-inch disk drives (17.8GB) installed inthe half inch height canister, configuring a row• RAID0 : 89.0GB• RAID5 : 71.2GB
Indiv-dualunit
DF350 K6601299-
Copyright ©1998, Hitachi, Ltd.
SPEC0355REV.1 May.1998 Oct.1998
Table 4.6.1 List of Rack Mount (RKWH) Type Component Models (Essential)Category Model Component name Specification Selection
Cache memory(*3)
DF-F350-C8E
Cache memory(8MB)
Cache memory (8MB) (8MB-board × 1) Select the cachememory to be mountedon CTL
DF-F350-C32E
Cache memory(32MB)
Cache memory (32MB) (32MB-board × 1) ASSY in unit of 2 boards(at least 2 boards)
DF-F350-C128E
Cache memory(128MB)
Cache memory (128MB) (128MB-board × 1)
Interface DF-F350-DWUDS
Rack mount (RKWH)type interface W/D(68PS)
Rack mount (RKWH) type wide differential,68-pin, pin-type, screw-locked (provided with aterminator)
Essential
DF-F350-DWUSS
Rack mount (RKWH)type interface W/S(68PS)
Rack mount (RKWH) type wide single-ended,68-pin, pin-type, screw-locked (provided with aterminator)
*1 Install one of the disk drives with capacities of 2.0GB, 4.1GB, 8.7GB, or 17.8GB according to thecapacity of the subsystem.
*2 RAID0 : Select the individual disk units (minimum five units) in units of a disk unit.RAID1 : Select the individual disk units (minimum four units) in units of two disk unit.RAID5
(4D+1P) : Select (a) low(s) of disk drives in units of a row.(3D+1P) : Select the individual disk units in units of four disk units.(2D+1P) : Select the individual disk units in units of three disk units.
RAIDA :Select the individual disk units in units of four disk units.*3 Mount either model of cache memory only.*4 It is necessary to use it with the Micro_Disk Ver.0307 or later.
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0360REV.7 Mar.1997 Jul.1997 May.1998 Oct.1998
(2) Optional Components
Table 4.6.2 List of Rack Mount (RKWH) Type Component Models (Optional)Category Model Component name Specification Selection
Spare diskdrive
DF-F350-A2E2
One 3.5-inch dickdrive (2.0GB)
3.5-inch disk drive (2.0GB) installed in the 1-inch height canister
• One spare disk isrequired for the entire
DF-F350-A3E4
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
subsystem.• Power supply for the
DF-F350-A2E4
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
spare disk drive is notrequired.
DF-F350-A2E4A
(For AS/400)
One 3.5-inch diskdrive (4.1GB)
3.5-inch disk drive (4.1GB) installed in the 1-inch height canister
• Mount a disk drivewhose capacity isequivalent to the
DF-F350-A2E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
maximum capacity ofthe disk drives
DF-F350-A2E8A
(For AS/400)
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the 1-inch height canister
mounted.
DF-F350-A1E8
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the halfinch height canister
DF-F350-A1E8A
(For AS/400)
One 3.5-inch diskdrive (8.7GB)
3.5-inch disk drive (8.7GB) installed in the halfinch height canister
DF-F350-A1E18
One 3.5-inch diskdrive (17.8GB)
3.5-inch disk drive (17.8GB) installed in thehalf inch height canister
Cache memory DF-F350-C8E
Cache memory See “cache memory” as the essentialcomponent.
See “cache memory” asthe essentialcomponent.
DF-F350-C32E
Up to 8 cache memoriescan be mounted.
DF-F350-C128E
Interface DF-F350-DWUDS
Interface See “interface” as the essential component. Additional disk drive
DF-F350-DWUSS
DF350 K6601299-
Copyright ©1998, Hitachi, Ltd.
SPEC0365REV.1 May.1998 Oct.1998
Table 4.6.2 List of Rack Mount (RKWH) Type Component Models (Optional)Category Model Component name Specification Selection
DF-F350-A2E2
3.5-inch disk drive See “Individual-unit disk drive” as the essentialcomponent.
• See “disk drive” as theessential component.
DF-F350-A3E4
• Selectable if moredisk drives can bemounted.
DF-F350-A2E4
DF-F350-A2E4A
(For AS/400)DF-F350-
A2E8Indivi-dualunit
DF-F350-A2E8A
(For AS/400)DF-F350-
A1E8DF-F350-
A1E8A(For AS/400)
Addit-ional
DF-F350-A1E18
diskdrive
DF-F350-E2E2
3.5-inch disk drive See “disk drive” row configuration as theessential component.
DF-F350-E3E4
DF-F350-E2E4
DF-F350-E2E4A
(For AS/400)DF-F350-
E2E8DF-F350-
E2E8A(For AS/400)
DF-F350-E1E8
DF-F350-E1E8A
(ForAS/400)DF-F350-
E1E18LAN board DF-F350-
G1M1LAN board for minitower type, etc.
LAN board for mini tower, cabinet, and rackmount types
DF-F350-G2M1
SNMP-compatibleLAN board for minitower type, etc.
SNMP-compatible remote maintenance LANboard for mini tower, cabinet, and rack mounttypes
Array controller DF-F350-F2WCF
Controller (aprogram product) forduplicating thesystem (RKWH)
Array controller for duplicating the system; aprogram product for mini tower, and cabinet,and rack mount (RKWH) types
• Controller can beduplicated.
• Mount the cachememory whosecapacity is equivalentto that mounted onthe basic controller.
Rack mountcabinet
DF-F350-U2 Rack for RKWH Rack for rack mount type RKWH (with ACpower cable)Up to four RKWHs can be mounted.
PC formaintenance
DF-F350-R1 PC for maintenance PC with the maintenance tool installed RS232C cableseparately required forconnecting the diskarray subsystem.
Rowconfi-
guration
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0370REV.6 Mar.1997 Jul.1997 Dec.1997
4.7 Accessories
The list of accessories is shown below.
Table 4.7.1 List of AccessoriesCategory Model Part name Specification Remarks
Power cable DF-F350-J1 Power cable 2.5 m, 2-pole power cable withgrounding terminal (plug shape:NEMA standard 5-15P)(AC 125 V 6 A)
See SPEC0610
DF-F350-J2 Power cable 2 m, 2-pole power cable withgrounding terminal(AC 250 V 6 A)
See SPEC0610
DF-F350-J3 Power cable 2 m, 2-pole power cable withgrounding terminal(AC 250 V 10 A)
See SPEC0610
Interface cable DF-F350-K350L Cable for HP9000/700Dif, 5m, 50-pin
Narrow-differential cable forHP9000/ 700, 5 m, 50-pin, pin/latchtype for Differential series
DF-F350-K450L N/D cable for 3050,5 m, 50-pin
Narrow-differential cable for 3050,5 m, 50-pin, bellows/latch type
DF-F350-K550L N/S short cable, 1.5m, 50-pin
Narrow single-ended short cable, 1.5m, 50-pin, pin/latch type
DF-F350-K650L N/S standard cable,3 m, 50-pin
Narrow single-ended standard cable,3 m, 50-pin, pin/latch type
DF-F350-K750L N/S short cable for3050, 1.5 m, 50-pin
Narrow single-ended short cable for3050, 1.5 m, 50-pin, bellows/latchtype
DF-F350-K850L N/S cable for 3050,3 m, 50-pin
Narrow single-ended cable for 3050,3 m, 50-pin, bellows/latch type
DF-F350-K068L Wide short cable for3050, 1.5 m, 68-pin
Wide short cable for 3050, 1.5 m,68-pin, bellows/latch type
DF-F350-K168L W/S cable for 3050,3 m, 68-pin
Wide single-ended cable for 3050, 3m, 68-pin, bellows/latch type
DF-F350-K268L W/D cable for3050, 5 m, 68-pin
Wide differential cable for 3050, 5m, 68-pin, bellows/latch type
DF-F350-K568L W/D cable for3050, 20 m, 68-pin
Wide differential cable for 3050, 20m, 68-pin, bellows/latch type
DF-F350-K068M Wide short cable for3050, 1.5 m, 68-pin
Wide short cable for 3050, 1.5 m,68-pin, mini bellows, screw-locked
DF-F350-K168M W/S cable for 3050,3 m, 68-pin
Wide single-ended cable for 3050, 3m, 68-pin, mini bellows, screw-locked
DF-F350-K268M W/D cable for3050, 5 m, 68-pin
Wide differential cable for 3050, 5m, 68-pin, mini bellows, screw-locked
DF-F350-K068S Daisy-chain cable,1.5 m, 68-pin
Daisy-chain cable, 1.5 m, 68-pin,pin-type, screw-locked
DF-F350-K168S W/D standard cable,5 m, 68-pin
Wide-differential standard cable, 5m, 68-pin, pin-type, screw-locked
DF-F350-K268S W/S standard cable,3 m, 68-pin
Wide single-ended standard cable, 3m, 68-pin, pin-type, screw-locked
DF-F350-K368S Wide special cable,10 m, 68-pin
Wide special cable, 10 m, 68-pin,pin-type, screw-locked
DF-F350-K468S Wide special cable,15 m, 68-pin
Wide special cable, 15 m, 68-pin,pin-type, screw-locked
(to be continued)
DF350 K6601299-
Copyright ©1997, 1998, Hitachi, Ltd.
SPEC0380REV.7 Mar.1997 Jul.1997 Feb.1998 May.1998
Category Model Part name Specification RemarksInterface cable DF-F350-K568S Daisy chain cable,
0.5 m, 68-pinDaisy-chain cable, 0.5 m, 68-pin,pin-type, screw-locked
DF-F350-K168R W/D cable forRS600, 5 m, 68-pin
Wide-differential cable forconnection with RS6000, 5 m, 68-pin, with special connectors
DF-F350-K168A W/D cable forAS/400, 5m, 68-pin
Wide-differential cable forconnection with AS/400, 5m, 68-pin, with special connectors
RS232C cable DF-F350-S1 RS232C cable 9pin - 9pin 5m See SPEC0580DF-F350-SH2 9pin - 25pin 5m See SPEC0590DF-F350-SH3 9pin - 25pin 10m See SPEC0590DF-F350-SS2 9pin - 25pin 5m See SPEC0600DF-F350-SS3 9pin - 25pin 10m See SPEC0600
SCSI terminator DF-F350-TWDS SCSI terminatorW/D
Wide differential terminator, 68-pin,pin-type, screw-locked
DF-F350-TWSS SCSI terminatorW/S
Wide single-ended terminator, 68-pin, pin-type, screw-locked
Mini tower typestand
DF-F350-H1M Floor stand for minitower type
Floor stand for mini tower type
Rack rail DF-F350-URHT HT rack rails Rails for Hitachi rackDF-F350-URAS AS rack rails Rails for IBM rack. (RKH, RKWH)DF-F350-URASD Rails for IBM rack.
(DKH, RKH, RKWH)DF-F350-URHP HP rack rails Rails for Hewlett-Packard rack.
(RKH, RKWH)DF-F350-URHPD Rails for Hewlett-Packard rack.
(DKH)DF-F350-URSH SH rack rails Rails for Shroff rack.
(DKH, RKH, RKWH)DF-F350-URRA Rails for Shroff rack. (RKH)
Rack power DF-F350-UPCJ U1 power cable AC power cable for U1cable DF-F350-UPCN U2 power cable AC power cable for U2Blank panel DF-F350-UP1 HT blank panel Blank panel for Hitachi U1/U2 rack
DF-F350-UP5 HT blank panel Blank panel for Hitachi U1/U2 rackDF-F350-UP6 HT blank panel Blank panel for Hitachi U1/U2 rack
Rack mount kit DF-F350-H1H DKH Type rackmount remodeling
DKH Type rack mount remodelingkit
DF-F350-H2H kit DKH Type rack mount remodelingkitExclusive for Hitachi FLORA rack
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0390REV.5 Mar.1997 Jul.1997
4.8 Rack Frames
4.8.1 U1 rack frame
The DF-F350-U1 rack frame can mount up to six units of the DF350 rack-mount (RKH) type (hereinafter
referred to as RKH) and consists of the power distribution box (PDB) used to supply AC power to the RKH,
panel that controls the RKH operation indication and start/stop in a centralized manner, and cooling fans. (See
Figure 4.8.1.)
Figure 4.8.1 U1 Rack Frame System Configuration
4.8.2 U2 rack frame
The DF-F350-U2 rack frame can mount up to four units of the DF350 rack-mount (RKWH) type (hereinafter
referred to as RKWH) and consists of the power distribution box (PDB; two sets mounted for the dual power
supply) used to supply AC power to the RKH and panel that controls the RKH operation indication and start/stop
in a centralized manner. (See Figure 4.8.2.)
Figure 4.8.2 U2 Rack Frame System Configuration
DF350-RKH
DF350-RKH
DF350-RKH
DF350-RKH
DF350-RKH
DF350-RKH
PANEL
FAN ASSY
PDB 178-254V AC
DF350-RKWH
DF350-RKWH
DF350-RKWH
DF350-RKWH
PANEL
Outlet (*1)
PDB
PDB
178-254V AC
178-254V AC
*1 Outlet is optional.
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0400REV.5 Mar.1997 Jul.1997
5. Interface
5.1 SCSI Connection Specifications
5.1.1 Interface cable (daisy-chain connection)
a + b + ... + n + Cable length inside the subsystem =<20 m (For differential SCSI)
a + b + ... + n + Cable length inside the subsystem =<5 m (For single-ended devices)
Note 1: Up to 8 devices including the host, this subsystem, and other SCSI devices can be connected to the SCSI
bus. (Up to 16 devices can be connected when they use Wide SCSI interface.) Since the cable length
inside the DF350 is 1.0 m (maximum), pay attention to the SCSI cable length upon connection.
Note 2: If DF350 is to be used as a single-ended SCSI device, the maximum transfer speed is limited to 20MB/s
(of wide SCSI) by default.
Note 3: Within approximately 3 seconds after the DF350 is started, it cannot respond with selection to the
command from the host. Therefore, the initiator should suppress command issuance during this period.
Alternatively, the host should be activated after it is confirmed that the DF350 is ready. Before the
subsystem is ready, reading from and writing to the subsystem are not allowed.
Note 4: Before disconnecting power for DF350, complete the power-off process on the host.
Note 5: When power is turned off with the main switch on the front of the subsystem (or when the SCSI
terminator power becomes low in remote mode), DF350 writes all data, remaining in the cache memory
and not reflected to the disk, to the disk (i.e. de-staging process). This process requires several seconds
to tens of minutes before the subsystem power is turned off. If power is directly disconnected with the
breaker switch on the rear of the equipment or with the breaker supply power to the subsystem, the de-
staging process is not allowed to be performed. Therefore, the cache memory enters the battery back-up
mode. In this case, the data assurance time is as per the cache back-up time shown in "2. Basic
Specifications". For normal power off, be sure to use the main switch on the front of the subsystem to
turn power off (or set the SCSI terminator power down to the Low level in remote mode), make sure
that the POWER LED goes out, then turn off the breaker switch. Also, perform this procedure before
maintenance such as replacement of each part.
Figure 5.1.1 DF350 Connection Specifications
DF350 DF350 DF350
SCSI bus
AC power
supply
GND
Terminator
a b n
(SCSI interface cable)
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0410REV.6 Mar.1997 Jul.1997 Dec.1997
5.1.2 System configuration
Note 1: Be sure to attach the terminator only to the device at the end of the cable.
Figure 5.1.2 System Configuration
Terminator
Host adapter
Host adapter
Host adapter
Host adapter
DF350
DF350
#0
DF350
#n
DF350
#0
DF350
#n
(a) Single connection
(b) Multi-controller connection
(c) Multi-initiator connection
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0420REV.5 Mar.1997 Jul.1997
5.1.3 Cable-side connector
Table 5.1.1 Connector
Numberof pins
Name Manufacturer’s model Interface specification
SCSI interfaceconnector
68 AMP Amplimite 050series made
Connector: 749111-6Cover: 750752-1
Single Ended Wide SCSIDifferential Wide SCSI
5.1.4 Cable
Cable type/rating
Control signal cable50-pin Hitachi Cable shielded cable 25P × 30 AWG or equivalent.
Cable impedance: 90 Ω ± 10 Ω at TDR
68-pin Hitachi Cable shielded cable 34P × 30 AWG or equivalent.Cable impedance: 90 Ω ± 10 Ω at TDR
5.1.5 Equipment-side connector shape (for pin-type connector)
Figure 5.1.3 Wide SCSI Interface Signal Connector
34 1
68 35
AMP 750737-7
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0430REV.5 Mar.1997 Jul.1997
5.1.6 Connector pin layout (for differential SCSI)
01 + DB12 - DB12 35
02 + DB13 - DB13 36
03 + DB14 - DB14 37
04 + DB15 - DB15 38
05 + DBP1 - DBP1 39
06 GND GND 40
07 + DB0 - DB0 41
08 + DB1 - DB1 42
09 + DB2 - DB2 43
10 + DB3 - DB3 44
11 + DB4 - DB4 45
12 + DB5 - DB5 46
13 + DB6 - DB6 47
14 + DB7 - DB7 48
15 + DBP - DBP 49
16 DIFFSENS GND 50
17 TERMPWR (*1, 2) TERMPWR (*1, 2) 51
18 TERMPWR (*1) TERMPWR (*1) 52
19 OPEN OPEN 53
20 + ATN - ATN 54
21 GND GND 55
22 + BSY - BSY 56
23 + ACK - ACK 57
24 + RST - RST 58
25 + MSG - MSG 59
26 + SEL - SEL 60
27 + C/D - C/D 61
28 + REQ - REQ 62
29 + I/O - I/O 63
30 GND GND 64
31 + DB8 - DB8 65
32 + DB9 - DB9 66
33 + DB10 - DB10 67
34 + DB11 - DB11 68
*1: If TERMPWR is not to be used, select OPEN (not used).
*2: When connecting pins 06 to 30 and 40 to 64 to a narrow SCSI device, do not connect pins 17 and 51.
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0440REV.5 Mar.1997 Jul.1997
(single ended <WIDE SCSI>)
01 GND - DB12 35
02 GND - DB13 36
03 GND - DB14 37
04 GND - DB15 38
05 GND - DBP1 39
06 GND - DB0 40
07 GND - DB1 41
08 GND - DB2 42
09 GND - DB3 43
10 GND - DB4 44
11 GND - DB5 45
12 GND - DB6 46
13 GND - DB7 47
14 GND - DBP 48
15 GND GND 49
16 GND GND 50
17 TERMPWR (*1, 2) TERMPWR (*1, 2) 51
18 TERMPWR (*1) TERMPWR (*1) 52
19 OPEN OPEN 53
20 GND GND 54
21 GND - ATN 55
22 GND GND 56
23 GND - BSY 57
24 GND - ACK 58
25 GND - RST 59
26 GND - MSG 60
27 GND - SEL 61
28 GND - C/D 62
29 GND - REQ 63
30 GND - I/O 64
31 GND - DB8 65
32 GND - DB9 66
33 GND - DB10 67
34 GND - DB11 68
*1: If TERMPWR is not to be used, select OPEN (not used).
*2: When connecting pins 06 to 30 and 40 to 64 to a Narrow SCSI device, do not connect pins 17 and 51.
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0450REV.5 Mar.1997 Jul.1997
5.1.7 Interface circuit (for differential ended SCSI)
Figure 5.1.4 Interface Circuit
ICtt : Part complying with EIA RS485
ICtr : Part complying with EIA RS485
R1 : 330 Ω ± 5%
R2 : 150 Ω ± 5%
5.1.8 Interface signal characteristics (for differential ended SCSI)
(1) Input characteristics
Ii (input current to the + and - terminals) : Within ±2.0 mA (See Note.)
Maximum input capacitance : 25 pF or lower
Note: Input voltage -7 to 12 VDC
(2) Output characteristics
VOL (low output voltage) : 1.7 V or lower (when IOL (low output current) is 55 mA)
VOH (high output voltage) : 2.7 V or higher (when IOH (high output current) is -55 mA)
VOD (differential voltage : 1.0 V or higher (when in-phase voltage is -7 to 12 V)
(3) Logically true value
When the potential of the + signal is higher than that of the - signal, the logic is true. If the potential of the -
signal is higher than that of the + signal, the logic is false.
ICtr
ICtt
+5VR1
R2
R1
+5VR1
R2
R1
ICtr
ICtt
<- signal>
<+ signal>
+ signal
- signal
True False
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0460REV.5 Mar.1997 Jul.1997
5.1.9 Interface circuit (for single ended SCSI)
Figure 5.1.5 Interface Circuit
ICtt : SN7438 or equivalent
ICtr : SN74CS240 or equivalent
R1 : 220 Ω ± 5%
R2 : 330 Ω ± 5%
5.1.10 Interface signal characteristics (for single ended SCSI)
(1) Input characteristics
"L" level : 0.0 to 0.8 VDC
"H" level : 2.0 to 5.25 VDC
Input load (IIL) : -0.4 mA (max.)
(2) Output characteristics
VOL (low output voltage) : 0.0 to 0.4 VDC
VOH (high output voltage) : 2.5 to 5.25 VDC
IOL (output current) : 48 mA
(3) Logically true value
All signals are active-low (true = "L").
ICtr
ICtt
ICtr
ICtt
R1 R1
R2 R2
+5V +5V
<- signal>
- signal
True False
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0470REV.5 Mar.1997 Jul.1997
5.1.11 SCSI bus signal
The initiator is connected to the target via the SCSI-2 bus interface (ANSI standard X3T9.2/86-109, REV10E).
Figure 5.1.6 shows the Wide SCSI bus signal conductors. Table 5.1.2 shows the meaning of each signal.
WIDE SCSI bus signal
Figure 5.1.6 Wide SCSI Bus Signal Conductors
Initiator
(HOST)Target
(DF350)
DB0 (Data Bus Bit 20)
DB1 (Data Bus Bit 21)
DB2 (Data Bus Bit 22)
DB3 (Data Bus Bit 23)
DB4 (Data Bus Bit 24)
DB5 (Data Bus Bit 25)
DB6 (Data Bus Bit 26)
DB7 (Data Bus Bit 27)
DBP (Data Bus Parity)
DB8 (Data Bus Bit 28)
DB9 (Data Bus Bit 29)
DB10 (Data Bus Bit 210)
DB11 (Data Bus Bit 211)
DB12 (Data Bus Bit 212)
DB13 (Data Bus Bit 213)
DB14 (Data Bus Bit 214)
DB15 (Data Bus Bit 215)
DBP1 (Data Bus Parity)
ATN (Attention)
BSY (Busy)
ACK (Acknowledge)
RST (Reset)
MSG (Message)
SEL (Select)
C/D (Control/Data)
REQ (Request)
I/O (Input/Output)
: Signal from the initiator to the target
: Signal from the target to the initiator
: Bi-directional signal
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0480REV.5 Mar.1997 Jul.1997
Table 5.1.2 Meanings of SCSI Bus Signals
Classification Signal name Description
Signal controlled by
the target
I/O
(Input/Output)
• Shows information flow direction on the data bus
I/O=1: From the target to the initiator
I/O=0: From the initiator to the target
• Identifies of the target or initiator
I/O=1: Re-selection (i.e. the target re-connects the initiator)
I/O=0: Selection (i.e. the initiator selects the target)
C/D
(Control/Data)
• Shows the type of information on the data bus
C/D=1: Command, status, or message
C/D=0: Data
MSG
(Message)
• If MSG=1, the SCSI bus is in the message phase.
Signal controlled by
the initiator and
BSY
(Busy)
• If BSY=1, the SCSI bus is in use.
target SEL
(Select)
• Selection control signal for selection/re-selection
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0490REV.5 Mar.1997 Jul.1997
(Table 5.1.2 --- continued)
Classification Signal name Description
Handshake signal
between the initiator
and target
REQ
(Request)
• Used for information transfer on the data bus along with ACK.
• The target sets REQ=1 for each data byte for data transfer with the
initiator.
ACK
(Acknowledge)
• Used for information transfer on the data bus along with REQ.
• When data sending/receiving is ready, the initiator sets ACK=1 in
response to REQ.
• To complete handshaking, the initiator should set ACK=0 in
response to REQ=0.
Signal controlled by
the initiator
RST
(Reset)
• Target resetting signal. If RST=1, the target is initialized.
ATN
(Attention)
• If ATN=1, the initiator has a message to be sent to the target.
Data bus signal DB15 ~ DB0
(Data Bus Bit215)
(Data Bus Bit20)
(WIDE SCSI bus)
• 8-bit data bus
• Becomes SCSI ID bit used to determine the priority in arbitration.
ID bit priority order is ((MSB)DB7 to DB0, DB15 to DB8=(LSB)).
DBP, DBP1
(Data Bus Parity)
(WIDE SCSI Bus)
• Data bus parity bit
• Odd parity
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0500REV.5 Mar.1997 Jul.1997
5.1.12 Bus phase
The SCSI bus states during operation between the initiator and target are classified into eight phases shown
below:
(1) Bus free phase
The SCSI bus is free and the initiator can start a new operation or the target can re-connect the initiator.
In the bus free phase, all signals on the SCSI bus are "0".
(2) Arbitration phase
In this phase, the initiator or target acquires the right to use the SCSI bus.
(3) Selection phase
In this phase, the initiator selects the target.
(4) Re-selection phase
In this phase, the target re-selects the initiator.
(5) Command phase
In this phase, the target receives a command from the initiator via the data bus.
(6) Data transfer phase
In this phase, data transfer with the initiator via the data bus is performed.
This phase is skipped if the command is not accompanied by data transfer.
(7) Status phase
In this phase, the status byte after command execution is transferred from the target to the initiator via the
data bus.
(8) Message phase
In this phase, message bytes are transferred from the target to the initiator or from the initiator to the target
via the data bus.
By following the eight steps for a command, a series of operations such as command receiving, execution, and
completion report are executed.
For information transfer phases (i.e. command, data transfer, status, and message phases), the target posts to the
initiator which phase is currently in progress with a combination of three signals; I/O, C/D, and MSG.
Table 5.1.3 shows the correspondence between the signal combinations and phases.
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0510REV.5 Mar.1997 Jul.1997
Table 5.1.3 Information Transfer Phases
Signal name Phase
MSG C/D I/O
0 0 0• Data transfer phase (Data is sent from the initiator to the
target)
0 0 1• Data transfer phase (Data is sent from the target to the
initiator)
0 1 0• Command phase (A command is received from the
initiator)
0 1 1• Status phase (A status is sent to the initiator)
1 0 0• Unused
1 0 1• Unused
1 1 0• Message phase (A message is sent from the initiator to the
target)
1 1 1• Message phase (A message is sent from the target to the
initiator)
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0520REV.5 Mar.1997 Jul.1997
Figure 5.1.7 Phase Transition (in the System Having Arbitration)
Notes:
• The solid line indicates the normal sequence.
• After resetting, any phase goes to the bus free phase.
• For details on messages, see "Hitachi Disk Array Subsystem SCSI Interface Specifications".
Bus free Arbitration
Selection
Messagetimeout
Command
Message-in
Re-selection
Message-in
Data
Message-in
Message-in
Message-in
Status
IdentifyIdentify
Disconnect (04)H
Disconnect(04)H
Save DataPointer(02)H
CommandComplete(00)H
Abort (06)H
Bus DeviseReset (0C)H
Re-selectiontimeout
Selectiontimeout
If arbitration fails
If arbitration is successful
ATN = 0
ATN = 1
When data transfer is not provided
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0530REV.5 Mar.1997 Jul.1997
5.1.13 Software outline (supported commands)
The controller supports the command in group 0 to 2, 7 in Table 5.1.4.
Table 5.1.4 Supported Commands (1/4)Operation Code Grope 0 Command Name
00H TEST UNIT READY
01H REZERO UNIT
03H REQUEST SENSE
04H FORMAT UNIT
07H REASSIGN BLOCKS
08H READ
0AH WRITE
0BH SEEK
12H INQUIRY
15H MODE SELECT
16H RESERVE
17H RELEASE
1AH MODE SENSE
1BH START/STOP UNIT
1CH RECEIVE DIAGNOSTIC RESULTS
1DH SEND DIAGNOSTIC
Table 5.1.4 Supported Commands (2/4)Operation Code Grope 1 Command Name
25H READ CAPACITY
28H READ (EXTEND)
2AH WRITE (EXTEND)
2BH SEEK (EXTEND)
2EH WRITE AND VERIFY
2FH VERIFY
35H SYNCHRONIZE CACHE
37H READ DEFECT DATA
3BH WRITE BUFFER
3CH READ BUFFER
Table 5.1.4 Supported Commands (3/4)Operation Code Grope 2 Command Name
55H MODE SELECT (10)
5AH MODE SENSE (10)
Table 5.1.4 Supported Commands (4/4)Operation Code Grope 7 Command Name
E8H READ WITH SKIP MASK
EAH WRITE WITH SKIP MASK
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0540REV.5 Mar.1997 Jul.1997
Table 5.1.5 lists the commands for direct access devices defined in the ANSI's SCSI standard but not supported
by this controller.
Table 5.1.5 List of Non-supported CommandsOperation Code Command Name (Alphabetical order) Remarks
40H CHANGE DEFINITION
39H COMPARE
18H COPY
3AH COPY AND VERIFY
36H LOCK-UNLOCK-CACHE
4CH LOG SELECT
4DH LOG SENSE
34H PRE-FETCH
1EH PREVENT-ALLOW MEDIUM REMOVAL
3EH READ LONG
31H SEARCH DATA EQUAL
30H SEARCH DATA HIGH
32H SEARCH DATA LOW
33H SET LIMITS
3FH WRITE LONG
41H WRITE SAME
5.1.14 Message
Table 5.1.6 lists the messages supported by the controller.
Table 5.1.6 Message CodesCode Description Direction Remarks00H COMMAND COMPLETE In01H EXTENDED MESSAGE In Out02H SAVE DATA POINTER In03H RESTORE POINTERS In04H DISCONNECT In05H INITIATOR DETECTED ERROR Out06H ABORT Out07H MESSAGE REJECT In Out08H NOOPERATION Out09H MESSAGE PARITY ERROR Out0AH LINKED COMMAND COMPLETE In0BH LINKED COMMAND COMPLETE (WITH FLAG) In0CH BUS DEVICE RESET Out0DH ABORT TAG Out0EH CLEAR QUEUE Out
0FH - 1FH RESEVED CODES20H SIMPLE QUEUE TAG In Out 2-byte message21H HEAD OF QUEUE TAG Out 2-byte message22H ORDERED QUEUE TAG Out 2-byte message23H IGNORE WIDE RESIDUE In 2-byte message
24H - 7FH Reseved Code80H - FFH IDENTIFY In Out
In : Controller to host Out : Host to controller
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0550REV.5 Mar.1997 Jul.1997
5.1.15 Status
The status byte is defined as shown in Tables 5.1.7 and 5.1.8. When each command is completed, the controller
reports the status to the host during the status phase. However, this excludes the case that the command is
cleared by the ABORT message, ABORT TAG message, CLEAR QUEUE message, BUS DEVICE RESET
message, or RESET status (including POWER ON RESET).
Table 5.1.7 Status ByteBit
Byte7 6 5 4 3 2 1 0
0R0
R0
Status Byte Code R0
R : Reserved
Table 5.1.8 Status Byte Code
Bit of Status Byte Status
5 4 3 2 1
0 0 0 0 0 GOOD
0 0 0 0 1 CHECK CONDITION
0 0 1 0 0 BUSY
0 1 0 0 0 INTERMEDIATE/GOOD
0 1 1 0 0 RESERVATION CONFLICT
1 0 1 0 0 QUEUE FULL
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0560REV.5 Mar.1997 Jul.1997
Status byte codes are defined as follows:
GOOD:
This status indicates that the controller completed the command successfully.
CHECK CONDITION:
This status indicates that the command ended abnormally due to an error, exception, or abnormal state
resulting in setting of the sense data.
After this status is reported, the host can acquire the detailed information on the error by issuing the
REQUEST SENSE command.
After the CHECK CONDITION status is returned to a host and before the REQUEST SENSE command is
issued, activation from another host may result in the BUSY status. Therefore, the REQUEST SENSE
command must be issued.
Note: If a command ends with the CHECK CONDITION status, be sure to issue the REQUEST
SENSE command without a tag. The REQUEST SENSE command with a tag may result in
incorrect reporting of the error.
BUSY:
This status indicates that the controller is busy.
The controller reports this status if it cannot accept the command from the host.
INTERMEDIATE/GOOD:
This status indicates that each command (excluding the last command) in the link is completed successfully.
If this status is not reported, the link command chain is disconnected.
RESERVATION CONFLICT:
This status is reported when the host attempts to access the logical unit reserved by another host. However,
this status is not reported for the RELEASE command. (The controller executes the RELEASE command.)
QUEUE FULL:
This status indicates that the command queue is full and the command from the host cannot be accepted.
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0570REV.5 Mar.1997 Jul.1997
5.2 RS232C
5.2.1 DF350 connector pin layout
The RS232C cable connector to be used on the DF350 side is shown in the figure below. For pin Nos. and
corresponding signals, see the table below.
54321
9876
D-sub 9pin
Hirose Denki RDED-9P-LNA(4-40) (05) or equivalent
Pin No. Signal name and description1 2 RxD : Received Data3 TxD : Transmitter Data4 DTR : Data Terminal Ready5 GND : Signal Ground6 DSR : Data Set Ready7 RTS : Request to Send8 CTS : Clear to Send9
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0580REV.5 Mar.1997 Jul.1997
5.2.2 RS232C cable (S1)
(1) Cable
L=5m
Connector A Connector B
Cable
Part No. Name Quantity Part namePart specification/type Manufacturer
RS232C 1 Cable UL20276 #28×8C Furukawa DenkoCable 2 Connector A 1 17JE-13090-02 (D8C) Daiichi Denshi
3 Connector B 1 17JE-13090-02 (D8C) Kogyo
(2) Connector pin layout and cabling
5 4 3 2 1
9 8 7 6
Connector A/B (9pin)
Connector A PIN# (9pin) 2 3 4 5 6 7 8 Connector B PIN# (9pin) 3 2 6 5 4 8 7
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0590REV.5 Mar.1997 Jul.1997
5.2.3 RS232C cable (SH2, SH3)
(1) Cable
SH2 L=5mSH3 L=10m
Connector A Connector B
Cable
Part No. Name Quantity Part namePart specification/type Manufacturer
RS232C 1 Cable UL20276 #28×8C Furukawa DenkoCable 2 Connector A 1 17JE-13090-02 (D8C) Daiichi Denshi
3 Connector B 1 17JE-23250-02 (D8C) Kogyo
(2) Connector pin layout and cabling
5 4 3 2 1
9 8 7 6
Connector A (9pin)
1 2 3 4 5 6 7 8 9 10 11 12 13
14 15 16 17 18 19 20 21 22 23 24 25
Connector B (25pin)
Connector A PIN# (9pin) 2 3 4 5 6 7 8 9Connector B PIN# (25pin) 3 2 20 7 6 4 5 22
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0600REV.5 Mar.1997 Jul.1997
5.2.4 RS232C cable (SS2, SS3)
(1) Cable
SS2 L=5mSS3 L=10m
Connector A Connector B
Cable
Part No. Name Quantity Part namePart specification/type Manufacturer
RS232C 1 Cable UL20276 #28×8C Furukawa DenkoCable 2 Connector A 1 17JE-13090-02 (D8C) Daiichi Denshi
3 Connector B 1 17JE-23250-02 (D8C) Kogyo
(2) Connector pin layout and cabling
5 4 3 2 1
9 8 7 6
Connector A (9pin)
1 2 3 4 5 6 7 8 9 10 11 12 13
14 15 16 17 18 19 20 21 22 23 24 25
Connector B (25pin)
Connector A PIN# (9pin) 1 2 3 4 5 6 7 8 Connector B PIN# (25pin) 4, 5 2 3 6 7 20 8 8
DF350 K6601299-
Copyright ©1997, Hitachi, Ltd.
SPEC0610REV.0 Dec.1997
5.3 Power Cable
5.3.1 Power cable(J1)
L=2.5m
Connector A Connector BCable
Cable name No. Name Quantity Model typeApplicable standard
/ ratingDF-F350-J1 1 Cable — PVC code UL CSAPower Cable 2 Connector A 1 NEMA Standard CN60320 5-15P For AC125V(15A)
3 Connector B 1 EN60320 Standard
5.3.2 Power cable(J2)
L=2m
Connector A Connector BCable
Cable name No. Name Quantity Model typeApplicable standard
/ ratingDF-F350-J2 1 Cable — PVC code UL CSAPower Cable 2 Connector A 1 EN60320-C14 AC125V(15A)
3 Connector B 1 EN60320-C13 For rack
5.3.3 Power cable(J3)
L=2m
Connector A Connector B
Cable
Cable name No. Name Quantity Model typeApplicable standard
/ ratingDF-F350-J3 1 Cable — CENELEC VDEPower Cable 2 Connector A 1 EN60320-C14 AC250V(10A)
3 Connector B 1 EN60320-C13 For rack