Deutsches SOFIA Institut Universität Stuttgart Second Gyro System for the SOFIA Telescope J.F....
-
Upload
ami-sullivan -
Category
Documents
-
view
216 -
download
1
Transcript of Deutsches SOFIA Institut Universität Stuttgart Second Gyro System for the SOFIA Telescope J.F....
![Page 1: Deutsches SOFIA Institut Universität Stuttgart Second Gyro System for the SOFIA Telescope J.F. Wagner Deutsches SOFIA Institut, Universität Stuttgart,](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649e9d5503460f94b9dc3b/html5/thumbnails/1.jpg)
Deutsches SOFIA Institut
Universität Stuttgart
Second Gyro Systemfor the SOFIA Telescope
J.F. Wagner
Deutsches SOFIA Institut, Universität Stuttgart, Germany
![Page 2: Deutsches SOFIA Institut Universität Stuttgart Second Gyro System for the SOFIA Telescope J.F. Wagner Deutsches SOFIA Institut, Universität Stuttgart,](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649e9d5503460f94b9dc3b/html5/thumbnails/2.jpg)
Symposium Gyro Technology 2009 2
Deutsches SOFIA Institut
Universität Stuttgart
• Wide Field Imager (WFI)• Fine Field Imager (FFI)• Focal Plane Imager (FPI)
aircraft vibrations aero-acoustics
controller
commandedattitude
actualattitude
actuatorsstructure and mechanics
gyroscopes
perturbations
data fusion
tracker correction
Attitude Control: Inertial Stabilization
+
{
![Page 3: Deutsches SOFIA Institut Universität Stuttgart Second Gyro System for the SOFIA Telescope J.F. Wagner Deutsches SOFIA Institut, Universität Stuttgart,](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649e9d5503460f94b9dc3b/html5/thumbnails/3.jpg)
Symposium Gyro Technology 2009 3
Deutsches SOFIA Institut
Universität Stuttgart
SOFIA’s Fiber Optic Gyroscopes
Optical sensor module
Opto-electronicmodule
Initial situation
• Telescope pointing budget allocatedfor gyro drift: 0.04 arcsec
• Very low noise requirementdominated gyro design
→ Optical fiber length 3.4 km→ Mean coil diameter 150 mm→ Closed loop operation
Performance: Angular increment < 0.001 arcsecDynamic range > 10.3 °/sBandwidth > 1 kHzRandom walk 0.0003 °/√hIn-run bias stability 0.003 °/h
![Page 4: Deutsches SOFIA Institut Universität Stuttgart Second Gyro System for the SOFIA Telescope J.F. Wagner Deutsches SOFIA Institut, Universität Stuttgart,](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649e9d5503460f94b9dc3b/html5/thumbnails/4.jpg)
Symposium Gyro Technology 2009 4
Deutsches SOFIA Institut
Universität Stuttgart
SOFIA’s Fiber Optic Gyroscopes
![Page 5: Deutsches SOFIA Institut Universität Stuttgart Second Gyro System for the SOFIA Telescope J.F. Wagner Deutsches SOFIA Institut, Universität Stuttgart,](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649e9d5503460f94b9dc3b/html5/thumbnails/5.jpg)
Symposium Gyro Technology 2009 5
Deutsches SOFIA Institut
Universität Stuttgart
Constant Performance
• Two data sets available over a period of 9 years
• Data show very constant low noise behaviour
Calibration 1999/2003 Calibration 2008
![Page 6: Deutsches SOFIA Institut Universität Stuttgart Second Gyro System for the SOFIA Telescope J.F. Wagner Deutsches SOFIA Institut, Universität Stuttgart,](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649e9d5503460f94b9dc3b/html5/thumbnails/6.jpg)
Symposium Gyro Technology 2009 6
Deutsches SOFIA Institut
Universität Stuttgart
Spare partRepair
Second Gyro System
First possibility: Exchange of the gyro box
Gyro Box
2nd
Gyro Box
NasmythTube
ATCU TASCU
Failure
Gyro Box
![Page 7: Deutsches SOFIA Institut Universität Stuttgart Second Gyro System for the SOFIA Telescope J.F. Wagner Deutsches SOFIA Institut, Universität Stuttgart,](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649e9d5503460f94b9dc3b/html5/thumbnails/7.jpg)
Symposium Gyro Technology 2009 7
Deutsches SOFIA Institut
Universität Stuttgart
Failure
Second Gyro System
Second possibility: Parallel system (hot standby)
Gyro Box
2nd
GyroBox
NasmythTube
ATCU TASCU
2nd
ATCU
Gyro Box ATCU
![Page 8: Deutsches SOFIA Institut Universität Stuttgart Second Gyro System for the SOFIA Telescope J.F. Wagner Deutsches SOFIA Institut, Universität Stuttgart,](https://reader036.fdocuments.us/reader036/viewer/2022062518/56649e9d5503460f94b9dc3b/html5/thumbnails/8.jpg)
Symposium Gyro Technology 2009 8
Deutsches SOFIA Institut
Universität Stuttgart
Second Gyro System
Comparison: Advantages (+) / Disadvantages (–) / Neutral (0)
Gyro Box Exchange Hot Standby
Accuracy + –
Cost – – –
Software modification 0 –
ATCU failure – – ++
“Save a mission” – ++
Flexibility of schedule – – +