Page 1
SITE LOCATION
(Scale 1:50000)
SITE PHOTOGRAPH
DETAILED SITE LOCATION
(Scale )1:2500
Original Sheet Size:
Surveyed By:
Date:Checked:Drawn: Date:
Cell Name
Site Address / Contact Details
Cell ID No
Drawing Title:
Purpose of issue:
Drawing Number:
TEFVF
Opt.
CTIL
A3
PLANNING
CORNERSTONE
Pack
Issue:
Dwg
Rev:
WHP Telecoms Ltd
Faraday Court
401 Faraday Street, Birchwood Park
Warrington, WA3 6GA
Tel: 01925 424100 Fax: 01925 424101
e-mail: [email protected]
The drawings comply with TEF ICNIRP guidelines.
Designed in accordance with TEF document: SDN0008
AutoCAD SHX Text
N.G.R E: 518361 N: 268095
AutoCAD SHX Text
PADDOCK FARM
AutoCAD SHX Text
TAYLORS LANE
AutoCAD SHX Text
CAMBRIDGESHIRE
AutoCAD SHX Text
PE18 5UW
AutoCAD SHX Text
PADDOCK FARM
AutoCAD SHX Text
10810801
AutoCAD SHX Text
MODIFICATION
AutoCAD SHX Text
ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERWISE
AutoCAD SHX Text
SITE LOCATION MAPS
AutoCAD SHX Text
17.12.20
AutoCAD SHX Text
17.12.20
AutoCAD SHX Text
Issued for Approval
AutoCAD SHX Text
17.12.20
AutoCAD SHX Text
= Public Access Route
AutoCAD SHX Text
= Right of Access
AutoCAD SHX Text
Based upon Ordnance Survey map extract with the permission of the Controller of Her Majesty's Stationery Office. Crown copyright. Licence No. 100022432
AutoCAD SHX Text
Based upon Ordnance Survey map extract with the permission of the Controller of Her Majesty's Stationery Office. Crown copyright. Licence No. 100022432
AutoCAD SHX Text
SITE LOCATION
AutoCAD SHX Text
DIRECTIONS TO SITE: A14 (SIGNS FOR THE MIDLANDS/CAMBRIDGE). TAKE THE RAMP TO THE MIDLANDS/HUNTINGDON. FOLLOW SIGNS FOR A14 AND MERGE ONTO HUNTINGDON RD/A14. CONTINUE TO FOLLOW A14. TAKE THE A14/A141 RAMP TO THE MIDLANDS/M1(N)/M6/KETTERING/CORBY/MARCH. AT THE ROUNDABOUT, TAKE THE 1ST EXIT ONTO A14. AT THE ROUNDABOUT, TAKE THE 1ST EXIT ONTO THE A1 RAMP TO LONDON. MERGE ONTO A1. AT THE ROUNDABOUT, TAKE THE 4TH EXIT ONTO GREAT N RD/A1. TURN LEFT ONTO TAYLORS LN. SITE IS AT END THROUGH FARM BUILDINGS.
AutoCAD SHX Text
SITE LOCATION
Page 2
Original Sheet Size:
Surveyed By:
Date:Checked:Drawn: Date:
Cell Name
Site Address / Contact Details
Cell ID No
Drawing Title:
Purpose of issue:
Drawing Number:
TEFVF
Opt.
CTIL
A3
PLANNING
CORNERSTONE
Pack
Issue:
Dwg
Rev:
WHP Telecoms Ltd
Faraday Court
401 Faraday Street, Birchwood Park
Warrington, WA3 6GA
Tel: 01925 424100 Fax: 01925 424101
e-mail: [email protected]
AutoCAD SHX Text
N.G.R E: 518361 N: 268095
AutoCAD SHX Text
PADDOCK FARM
AutoCAD SHX Text
TAYLORS LANE
AutoCAD SHX Text
CAMBRIDGESHIRE
AutoCAD SHX Text
PE18 5UW
AutoCAD SHX Text
PADDOCK FARM
AutoCAD SHX Text
10810801
AutoCAD SHX Text
MODIFICATION
AutoCAD SHX Text
ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERWISE
AutoCAD SHX Text
EXISTING SITE PLAN
AutoCAD SHX Text
17.12.20
AutoCAD SHX Text
17.12.20
AutoCAD SHX Text
Issued for Approval
AutoCAD SHX Text
17.12.20
AutoCAD SHX Text
EXISTING SITE PLAN
AutoCAD SHX Text
SOUTH WEST ELEVATION
AutoCAD SHX Text
GROUND LEVEL 0.00m GL
AutoCAD SHX Text
RIDGE LEVEL +9.00m AGL
AutoCAD SHX Text
YARD HARDSTANDING
AutoCAD SHX Text
EXISTING ELECTRICAL METER CABINET ON A COMBINED CONCRETE BASE.
AutoCAD SHX Text
EXISTING 300mm WIDE OVERHEAD CABLE TRAY AND SUPPORT POLES
AutoCAD SHX Text
EXISTING 1.8m HIGH CHANLINK FENCE WITH 3 STRANDS BARBED WIRE OVER AND 1.0m WIDE ACCESS GATE
AutoCAD SHX Text
EXISTING REDUNDANT TSC CABINET ON COMBINED CONCRETE BASE
AutoCAD SHX Text
EXISTING 100mm WIDE CONDUIT FOR POWER
AutoCAD SHX Text
EXISTING REDUNDANT ULTRASITE CABINET ON COMBINED CONCRETE BASE
AutoCAD SHX Text
EXISTING 15.0m HIGH R&T SWANN MONOPOLE TOWER ON CONCRETE BASE
AutoCAD SHX Text
EXISTING 100mm WIDE CONDUIT FOR POWER
AutoCAD SHX Text
EXISTING OUTDOOR ELTEK 4TH GEN PSU ON COMBINED CONCRETE BASE
AutoCAD SHX Text
EXISTING OUTDOOR 42U RACKS ON COMBINED CONCRETE BASE
AutoCAD SHX Text
EXISTING 300mm WIDE OVERHEAD CABLE TRAY AND SUPPORT POLES
AutoCAD SHX Text
EXISTING ISOLATOR SWITCH ON COMBINED CONCRETE BASE
AutoCAD SHX Text
EXISTING 12No. 5-50 FEEDERS BANDED EXTERNALLY TO TOWER
Page 3
Original Sheet Size:
Surveyed By:
Date:Checked:Drawn: Date:
Cell Name
Site Address / Contact Details
Cell ID No
Drawing Title:
Purpose of issue:
Drawing Number:
TEFVF
Opt.
CTIL
A3
PLANNING
CORNERSTONE
Pack
Issue:
Dwg
Rev:
WHP Telecoms Ltd
Faraday Court
401 Faraday Street, Birchwood Park
Warrington, WA3 6GA
Tel: 01925 424100 Fax: 01925 424101
e-mail: [email protected]
The drawings comply with TEF ICNIRP guidelines.
Designed in accordance with TEF document: SDN0008
AutoCAD SHX Text
N.G.R E: 518361 N: 268095
AutoCAD SHX Text
PADDOCK FARM
AutoCAD SHX Text
TAYLORS LANE
AutoCAD SHX Text
CAMBRIDGESHIRE
AutoCAD SHX Text
PE18 5UW
AutoCAD SHX Text
PADDOCK FARM
AutoCAD SHX Text
10810801
AutoCAD SHX Text
PROPOSED SITE PLAN
AutoCAD SHX Text
MODIFICATION
AutoCAD SHX Text
ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERWISE
AutoCAD SHX Text
PROPOSED SITE PLAN
AutoCAD SHX Text
17.12.20
AutoCAD SHX Text
17.12.20
AutoCAD SHX Text
Issued for Approval
AutoCAD SHX Text
17.12.20
AutoCAD SHX Text
SOUTH WEST ELEVATION
AutoCAD SHX Text
GROUND LEVEL 0.00m GL
AutoCAD SHX Text
RIDGE LEVEL +9.00m AGL
AutoCAD SHX Text
YARD HARDSTANDING
AutoCAD SHX Text
EXISTING ELECTRICAL METER CABINET ON A COMBINED CONCRETE BASE.
AutoCAD SHX Text
EXISTING 300mm WIDE OVERHEAD CABLE TRAY AND SUPPORT POLES
AutoCAD SHX Text
EXISTING 1.8m HIGH CHANLINK FENCE WITH 3 STRANDS BARBED WIRE OVER AND 1.0m WIDE ACCESS GATE
AutoCAD SHX Text
EXISTING REDUNDANT TSC CABINET ON COMBINED CONCRETE BASE
AutoCAD SHX Text
EXISTING 100mm WIDE CONDUIT FOR POWER
AutoCAD SHX Text
EXISTING REDUNDANT ULTRASITE CABINET ON COMBINED CONCRETE BASE
AutoCAD SHX Text
EXISTING 15.0m HIGH R&T SWANN MONOPOLE TOWER ON CONCRETE BASE
AutoCAD SHX Text
EXISTING 100mm WIDE CONDUIT FOR POWER
AutoCAD SHX Text
EXISTING OUTDOOR ELTEK 4TH GEN PSU ON COMBINED CONCRETE BASE
AutoCAD SHX Text
EXISTING OUTDOOR 42U RACKS ON COMBINED CONCRETE BASE TO BE UPGRADED INTERNALLY
AutoCAD SHX Text
EXISTING 300mm WIDE OVERHEAD CABLE TRAY AND SUPPORT POLES TO BE UTILISED FOR PROPOSED UPGRADE
AutoCAD SHX Text
EXISTING ISOLATOR SWITCH ON COMBINED CONCRETE BASE
AutoCAD SHX Text
EXISTING 12No. 5-50 FEEDERS BANDED EXTERNALLY TO TOWER
Page 4
Original Sheet Size:
Surveyed By:
Date:Checked:Drawn: Date:
Cell Name
Site Address / Contact Details
Cell ID No
Drawing Title:
Purpose of issue:
Drawing Number:
TEFVF
Opt.
CTIL
A3
PLANNING
CORNERSTONE
Pack
Issue:
Dwg
Rev:
WHP Telecoms Ltd
Faraday Court
401 Faraday Street, Birchwood Park
Warrington, WA3 6GA
Tel: 01925 424100 Fax: 01925 424101
e-mail: [email protected]
AutoCAD SHX Text
N.G.R E: 518361 N: 268095
AutoCAD SHX Text
PADDOCK FARM
AutoCAD SHX Text
TAYLORS LANE
AutoCAD SHX Text
CAMBRIDGESHIRE
AutoCAD SHX Text
PE18 5UW
AutoCAD SHX Text
PADDOCK FARM
AutoCAD SHX Text
10810801
AutoCAD SHX Text
MODIFICATION
AutoCAD SHX Text
ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERWISE
AutoCAD SHX Text
EXISTING SITE ELEVATION
AutoCAD SHX Text
17.12.20
AutoCAD SHX Text
17.12.20
AutoCAD SHX Text
Issued for Approval
AutoCAD SHX Text
17.12.20
AutoCAD SHX Text
EXISTING SOUTH WEST ELEVATION
AutoCAD SHX Text
U/S OF EXISTING ANTENNAS 15.7m AGL
AutoCAD SHX Text
TOP OF EXISTING ANTENNAS 17.7m AGL
AutoCAD SHX Text
C/L OF EXISTING TEF DISH 14.5m AGL
AutoCAD SHX Text
EXISTING ELECTRICAL METER CABINET ON A COMBINED CONCRETE BASE.
AutoCAD SHX Text
EXISTING 1.8m HIGH CHANLINK FENCE WITH 3 STRANDS BARBED WIRE OVER AND 1.0m WIDE ACCESS GATE
AutoCAD SHX Text
EXISTING REDUNDANT TSC CABINET ON COMBINED CONCRETE BASE
AutoCAD SHX Text
EXISTING REDUNDANT ULTRASITE CABINET ON COMBINED CONCRETE BASE
AutoCAD SHX Text
EXISTING 15.0m HIGH R&T SWANN MONOPOLE TOWER ON CONCRETE BASE
AutoCAD SHX Text
EXISTING OUTDOOR ELTEK 4TH GEN PSU ON COMBINED CONCRETE BASE (BEHIND)
AutoCAD SHX Text
EXISTING OUTDOOR 42U RACKS ON COMBINED CONCRETE BASE (BEHIND)
AutoCAD SHX Text
EXISTING 1No. 300 DISH ON DISHMOUNTED FIXED TO TOTWER
AutoCAD SHX Text
EXISTING 3No. ANTENNA ON SUPPORT POLES MOUNTED TO TOWER HEADFRAME
AutoCAD SHX Text
EXISTING 12No. 5-50 FEEDERS BANDED EXTERNALLY TO TOWER
Page 5
Original Sheet Size:
Surveyed By:
Date:Checked:Drawn: Date:
Cell Name
Site Address / Contact Details
Cell ID No
Drawing Title:
Purpose of issue:
Drawing Number:
TEFVF
Opt.
CTIL
A3
PLANNING
CORNERSTONE
Pack
Issue:
Dwg
Rev:
WHP Telecoms Ltd
Faraday Court
401 Faraday Street, Birchwood Park
Warrington, WA3 6GA
Tel: 01925 424100 Fax: 01925 424101
e-mail: [email protected]
The drawings comply with TEF ICNIRP guidelines.
Designed in accordance with TEF document: SDN0008
AutoCAD SHX Text
N.G.R E: 518361 N: 268095
AutoCAD SHX Text
PADDOCK FARM
AutoCAD SHX Text
TAYLORS LANE
AutoCAD SHX Text
CAMBRIDGESHIRE
AutoCAD SHX Text
PE18 5UW
AutoCAD SHX Text
PADDOCK FARM
AutoCAD SHX Text
10810801
AutoCAD SHX Text
MODIFICATION
AutoCAD SHX Text
ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERWISE
AutoCAD SHX Text
PROPOSED SITE ELEVATION
AutoCAD SHX Text
17.12.20
AutoCAD SHX Text
17.12.20
AutoCAD SHX Text
Issued for Approval
AutoCAD SHX Text
17.12.20
AutoCAD SHX Text
PROPOSED SOUTH WEST ELEVATION
AutoCAD SHX Text
U/S OF EXISTING ANTENNAS 15.7m AGL
AutoCAD SHX Text
TOP OF EXISTING ANTENNAS 17.7m AGL
AutoCAD SHX Text
C/L OF EXISTING TEF DISH 14.5m AGL
AutoCAD SHX Text
EXISTING ELECTRICAL METER CABINET ON A COMBINED CONCRETE BASE.
AutoCAD SHX Text
EXISTING 1.8m HIGH CHANLINK FENCE WITH 3 STRANDS BARBED WIRE OVER AND 1.0m WIDE ACCESS GATE
AutoCAD SHX Text
EXISTING REDUNDANT TSC CABINET ON COMBINED CONCRETE BASE
AutoCAD SHX Text
EXISTING REDUNDANT ULTRASITE CABINET ON COMBINED CONCRETE BASE
AutoCAD SHX Text
EXISTING 15.0m HIGH R&T SWANN MONOPOLE TOWER ON CONCRETE BASE
AutoCAD SHX Text
EXISTING OUTDOOR ELTEK 4TH GEN PSU ON COMBINED CONCRETE BASE (BEHIND)
AutoCAD SHX Text
EXISTING OUTDOOR 42U RACKS ON COMBINED CONCRETE BASE (BEHIND) TO BE UPGRADED INTERNALLY
AutoCAD SHX Text
EXISTING 1No. 300 DISH ON DISHMOUNTED FIXED TO TOTWER
AutoCAD SHX Text
EXISTING 3No. ANTENNA ON SUPPORT POLES MOUNTED TO TOWER HEADFRAME TO BE UITLISED FOR PROPOSED UPGRADE
AutoCAD SHX Text
PROPOSED 6No. FEEDERS TO BE BANDED TO MONOPOLE AT 1m CENTRES
AutoCAD SHX Text
EXISTING 12No. 5-50 FEEDERS BANDED EXTERNALLY TO TOWER