DESIGN VERIFICATION OF A RESIDENTIAL BUILDING
ByK.Azarudeen-13BCL0096S.Muthukumar-13BCL0304P.Mohankumar-13BCL0327
![Page 2: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/2.jpg)
PROBLEM DEFINITION
• Design Verification of a residential building using a software - (Staad pro 2015) .
• Residential building of G+1 floor from a location(Pudukottai) is taken for verification
![Page 3: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/3.jpg)
THE DESIGNED PLAN OF BUILDING
![Page 4: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/4.jpg)
![Page 5: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/5.jpg)
SNAPS OF THE BUILDING
![Page 6: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/6.jpg)
VALUES ADOPTED
• SLAB: 0.15m (depth)• BEAM: 0.25m x 0.3m• COLUMN: 0.3m x 0.3m• LIVE LOAD: 3kN/m (maximum adopted)
![Page 7: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/7.jpg)
DESCRIPTION
• The buildings live load and dead load is calculated from the type of material used and the dimensions
• Dimensions of slab, beams, column, footing of a residential building are verified for compliance to Indian Code
• M20 concrete and Fe415 steel have been used for this building• The plan and photos of the building are provided.
![Page 8: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/8.jpg)
3D RENTERING OF THE RESIDENTIAL BUILDING
![Page 9: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/9.jpg)
DEAD LOAD LIVE LOAD
![Page 10: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/10.jpg)
LOAD COMBINATION OF DL & LL
![Page 11: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/11.jpg)
EXCEL SHEET FOR RECTANGULAR BEAM CHECK
![Page 12: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/12.jpg)
EXCEL SHEET FOR ONEWAY SLAB CHECK
![Page 13: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/13.jpg)
EXCEL SHEET FOR TWOWAY SLAB CHECK
![Page 14: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/14.jpg)
Learning basics of IS CODE Books
Designing a residential building
Make an Excel calculation to
design Beam,Coloumn,
Slab
Analysing the building in STAAD pro and
conclusion
Learning basics of
STAAD PRO
Steps involved
![Page 15: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/15.jpg)
PARAMETERS 1st 2nd 3rd 4t
h1st 2nd 3rd 4th 1st
Learning basics of STAAD PRO
Learning basics of ISCODE BooksDesigning a residential building
Make an Excel calculation to
design Beam,Coloumn,
Slab
Verify the calculation values to STAAD PRO output values
2nd 3rd 4th 1st 2nd 3rd 4th
JULY AUGUST SEPTEMBER
OCTOBERACTIVITY CHART
![Page 16: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/16.jpg)
ERRORS & MISTAKES
• Error caused in assigning the dimensions to the particulars
• Beams were not intersected properly which leads to error in calculation
• Not intersecting the slabs.• Assigning live load in wrong directions.• Worksheet assigning errors.• Assuming wrong standard values in calculations.
![Page 17: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/17.jpg)
LEARNIGS
• Design a building using STAAD pro for • 1)Dead load and live load assigning• 2)Dimension assigning• 3) Basic kinds of possible errors• 4) Problems in automatic load design.• Learned to use excel sheet.• IS 875(part2) for residential building.• Basic design of Beams, Colums, Slabs in worksheet and
hand calculations.
![Page 18: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/18.jpg)
REFERENCES
• IS: 875(part 1), IS: 875(part 2)• IS 456:2000, SP-16• https://youtu.be/Ae44Fp8JmKE• staad pro and excel tutorials from youtube
![Page 19: design verification of residential building](https://reader030.fdocuments.us/reader030/viewer/2022033103/587318ba1a28ab673e8b5bbd/html5/thumbnails/19.jpg)
CONCLUSIONS
• The resistance to the live load and dead load is verified for beams,columns,and slabs of the building.
• The results were compared to the actual plan and the safety criteria is checked.