Design Project - College of Engineering - Purdue University · Web viewEnjoy safety and security...

10
ECE 477 Digital Systems Senior Design Project Rev 8/09 Homework 13: User Manual Team Code Name: ____Digijock Home Security ___________________ Group No. __7 ___ NOTE: This is one of the last sections needed to finish the Final Report. This homework will count toward each team member’s grade, and therefore all team members should participate equally in § User Manual Outline: Brief (marketing-style) product description Product illustration annotated with callouts for each control/display Product setup instructions Product use instructions Product troubleshooting instructions Evaluation: SCORE DESCRIPTION 10 Excellent – among the best papers submitted for this assignment. Very few corrections needed for version submitted in Final Report. 9 Very good – all requirements aptly met. Minor additions/corrections needed for version submitted in Final Report. 8 Good – all requirements considered and addressed. Several noteworthy additions/corrections needed for version submitted in Final Report. 7 Average – all requirements basically met, but some revisions in content should be made for the version submitted in the Final Report. 6 Marginal – all requirements met at a nominal level. Significant revisions in content should be made for the version submitted in the Final Report. * Below the passing threshold – major revisions required to meet report requirements at a nominal level. Revise and resubmit. * Resubmissions are due within one week of the date of return, and will be awarded a score of “6” provided all report requirements have been met at a nominal level. Include this sheet as a cover page for your report

Transcript of Design Project - College of Engineering - Purdue University · Web viewEnjoy safety and security...

Page 1: Design Project - College of Engineering - Purdue University · Web viewEnjoy safety and security for the 21st century and welcome to the Digijock Home Security family. RSU features:

ECE 477 Digital Systems Senior Design Project Rev 8/09

Homework 13: User Manual

Team Code Name: ____Digijock Home Security___________________ Group No. __7___

NOTE: This is one of the last sections needed to finish the Final Report. This homework will count toward each team member’s grade, and therefore all team members should participate equally in completing it. The User Manual should be about 5 pages in length (one page per bullet).

§

User Manual Outline: Brief (marketing-style) product description Product illustration annotated with callouts for each control/display Product setup instructions Product use instructions Product troubleshooting instructions

Evaluation:

SCORE DESCRIPTION

10 Excellent – among the best papers submitted for this assignment. Very few corrections needed for version submitted in Final Report.

9 Very good – all requirements aptly met. Minor additions/corrections needed for version submitted in Final Report.

8 Good – all requirements considered and addressed. Several noteworthy additions/corrections needed for version submitted in Final Report.

7 Average – all requirements basically met, but some revisions in content should be made for the version submitted in the Final Report.

6 Marginal – all requirements met at a nominal level. Significant revisions in content should be made for the version submitted in the Final Report.

* Below the passing threshold – major revisions required to meet report requirements at a nominal level. Revise and resubmit.

* Resubmissions are due within one week of the date of return, and will be awarded a score of “6” provided all report requirements have been met at a nominal level.

Include this sheet as a cover page for your report

Page 2: Design Project - College of Engineering - Purdue University · Web viewEnjoy safety and security for the 21st century and welcome to the Digijock Home Security family. RSU features:

DHS Recycling Declaration:For information regarding the recycling of this product, please contact the company from which you originally purchased it. Do NOT dispose of this with regular trash.

Caution: Be sure to check your alarm system at least once every six months Replace your RSU’s every 5 year. Impacts or drops can seriously compromise the device operations

ECE 477 Digital Systems Senior Design Project Rev 8/09

Digijock Home SecurityUser Manual

Congratulations on your purchase! The Digijock Home Security is a wireless alarm system that will protect your home or your small business from fire and burglary. Consisting of multiple remote sensor units (RSUs) and a central monitoring station (CMS), the system not only gives you the peace of mind of a safe home, but it also gives you the power to control your home security system through a simple internet connection. Enjoy safety and security for the 21st century and welcome to the Digijock Home Security family.

RSU features: CMS features: Motion sensor • USB LCD-based user interface Noise sensor • USB keypad Smoke sensor • USB siren alarm Temperature sensor • XBee wireless module Bicolor LED • Ethernet connection Siren alarm • Atom Board LCD-based user interface XBee wireless module Backup battery AC-DC 9V electrical adapter

NOT included but needed: Battery backup for CMS A computer with an internet connection

Product Description:

Page 3: Design Project - College of Engineering - Purdue University · Web viewEnjoy safety and security for the 21st century and welcome to the Digijock Home Security family. RSU features:

ECE 477 Digital Systems Senior Design Project Rev 8/09

Central Monitoring Station(CMS):

Remote Sensor Unit (RSU):

Setting Up Your DHS System:

(2)

(1)

(6)

(7)

(4)

(3)

(5)(2)

(1)

(5)

(4)

(3)

(5)

Components and dimensions:

5.9x8.7x2.4 inches (LxWxH)

(1) Power connection

(2) Ethernet connection

(3) USB LCD

(4) USB Keypad

(5) USB Speaker output

Components and dimensions:

5.9x8.7x2.4 inches (LxWxH)

(1) Bicolor LED

(2) 2 row LCD (16 characters)

(3) Microphone (noise sensor)

(4) Power connection

(5) Motion sensor (10m range)

(6) Speaker output

(7) Photoelectric smoke sensor

Page 4: Design Project - College of Engineering - Purdue University · Web viewEnjoy safety and security for the 21st century and welcome to the Digijock Home Security family. RSU features:

ECE 477 Digital Systems Senior Design Project Rev 8/09

Placement:

1. Strategically place the two RSUs near possible entryways and fire hazards. Make sure they are in the interior of the building and not in enclosed areas.

2. Hang the two RSUs approximately 3/4 of the way up on the wall, facing directly towards the area of interest. It should be close to an electrical outlet.Once all units are plugged in, press the reset button on the back of each device.

3. The CMS needs to be located near a place of common entry. Again, it is also necessary to place it by an electrical outlet. It also requires an Ethernet connection. Be careful! The CMS does NOT have monitoring sensors. You need an RSU placed in the same room.

Software Registration and Setup:

1. On your computer please type the following web address into an Internet browser.

<www.digijockhomesecurity.com>

2. Click on the “Register” button. (Figure 1)

3. Fill in the requested information. (Figure 2)

4. Once you have filled out the required information

on the Registration page, click Register and re-enter

your information to login to view data.

5. To verify your information, click on the User

Information tab. Here you can change and update

your information and passwords at any point in

time. Updates occur instantaneously. (Figure 3)

How to Use Your DHS System:

Figure 1

Figure 2

Figure 3

Figure 3

Page 5: Design Project - College of Engineering - Purdue University · Web viewEnjoy safety and security for the 21st century and welcome to the Digijock Home Security family. RSU features:

ECE 477 Digital Systems Senior Design Project Rev 8/09

Central Monitoring Station(CMS):

1. After registering your system on the website, you can use the keypad on the CMS to control

the state of your device. The system let you choose among 4 different commands:

Deactivated (code 1 ) = only the smoke sensor is on (green light on the RSU)

Activated (code 2 ) = all the RSU’s sensors are on (red light on the RSU)

Test (code 3 ) = check the sirens of the system with a smoke alarm test

Admin (code 4 )= change the CMS password (default CMS password = 1234)

* the CMS password is different from your login password!

** you need to be in the Deactivated mode to change the CMS password

2. To change from one state to another enter the command code followed by the CMS password.

Then press Enter.

Example: Activate alarms = 21234

3. When entering the home and the alarm is Activated, you have 15 seconds to deactivate the

alarm otherwise the alarm will sound.

4. To turn off the siren, deactivate the system (example= 11234)

Note: in non-alarm conditions the CMS and RSU will display the temperature of the room.

Web Server:

1. The web server lets you control your alarm system from anywhere with a simple Internet

connection. After connecting to <www.digijockhomesecurity.com> and logging in to your

account, the “User information” page will display in the “Current State” window the state of

your alarm system. The same window lets you change the system state by using the drop down

menu (press the “Update” button after selecting). (Figure 4)

2. If an alarm has been triggered, the same page will show you which RSU and what sensor has

been triggered. The system will also use the email address and phone number you entered

during registration to notify you of the emergency. (Figure 5)

CODEPASSWORD

Figure 4 Figure 5Figure 4

Page 6: Design Project - College of Engineering - Purdue University · Web viewEnjoy safety and security for the 21st century and welcome to the Digijock Home Security family. RSU features:

ECE 477 Digital Systems Senior Design Project Rev 8/09

Troubleshooting Your DHS System:

Problem Possible cause Solution

The RSU doesn’t produce noise 1. Lack of power (the LCD is off as well)2. Bad communication with the CMS

1. Try plugging the device into a different outlet. Try replacing the internal backup battery. To replace the battery, carefully open the RSU. Locate the battery and replace it with an alkaline 9V battery.2. Try to test the smoke detector using the CMS “Test” state. If the alarm does not turn on, the problem is in the wireless communication. It affects only noise and motion detection alarm.

The CMS doesn’t produce noise 1. Lack of power (the LCD is off as well)2. Damage in the internal wiring

1. Try plugging the device into a different outlet.2. Unit must be replaced (test the RCU, it could be still functional and able to protect your house).

Motion sensor isn’t working(in “Activated” state)

1. Dust on the lens2. Bad wireless communication3. Device damaged

1. Carefully clean the surface of all dust (DO NOT use liquid!)2. The problem could be either in the RSU or in the CMS. Call manufacturer for maintenance.3. The device needs to be replaced

Smoke, noise, or motion sensor is not working

1. Device is damaged 1. The RSU needs to be replaced

The LCD displays unexpected characters (RSU)

1. Internal software stall2. The LCD is broken

1. Press the reset button on the back of the RSU (try more than once if needed). 2. The RSU needs to be replaced.

The LED shows the wrong color (or no color)

1. Internal software problem2. LED broken

1. Unplug and plug in the RSU. Then press the reset button on the back.2. LED needs to be replaced (the RSU is still functional if the LCD is on)

Digijock Home Security (USA): 123 Phaik St, West Lafayette, IN 47906. Phone: (123) 555 – 1234

MADE IN THE U.S.A.