Design of Slender Tall Buildings for Wind & Earthquake - CEE

110
Design of Slender Tall Buildings for Wind & Earthquake Presented by Dr. Juneid Qureshi Director (Group Design Division) Meinhardt Singapore Pte Ltd Regency Steel Asia Symposium on Latest Design & Construction Technologies for Steel and Composite Steel-Concrete Structures 09 July 2015

Transcript of Design of Slender Tall Buildings for Wind & Earthquake - CEE

Page 1: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Design of Slender Tall Buildings for Wind & Earthquake

Presented by

Dr. Juneid Qureshi

Director (Group Design Division) Meinhardt Singapore Pte Ltd

Regency Steel Asia Symposium on Latest Design & Construction Technologies for Steel and Composite Steel-Concrete Structures09 July 2015

Page 2: Design of Slender Tall Buildings for Wind & Earthquake - CEE

AGENDA

01Structural Design Challenges for Tall Buildings

02Structural Systems for Tall Buildings

03Key Considerations for Seismic Design

04Review of BC3

07Cost Comparison of Concrete vs. Composite Tall Building

05Case Studies

06Comparison of Wind & Seismic Effects

08Concluding Remarks

Page 3: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Structural Design Challenges for Tall Buildings

01

Page 4: Design of Slender Tall Buildings for Wind & Earthquake - CEE

� Balancing structural needs vs. project demands are always a challenge …..specially for

tall buildings.

Structural Design Challenges for Tall Buildings

Developers Requirements

Architectural Vision

Construction ConstraintsStructural NeedsOthers?

Page 5: Design of Slender Tall Buildings for Wind & Earthquake - CEE

h

w

w

2h

W

2W

16

M 4M

Short Buildings:

• Generally strength governs design

• Gravity loads predominant

Intermediate Buildings:

• Strength / drift governs design

• Gravity / lateral loads predominant

Tall Buildings:

• Generally drift / building motion

governs design

• Lateral loads predominant

Source: CTBUH

Structural Design Challenges for Tall Buildings

Premium for Height

Page 6: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Structural Design Challenges for Tall Buildings

� As buildings get taller, wind-induced dynamic response starts to dictates the design.

Fluctuating Wind

Speed, V(z,t)

Mean Wind Speed, V(z)

Zg

(60

0m

)

V

V(z) = Vg (z/zg)α

α depends on terrain

Wind

Static Loads, A

Low Freq. Background

Comp., B

Dynamic Loads

Resonant Comp., C A,B &C

B &C B &C

A & B : Dependent on building geometry & turbulence environment

C : Dependent on building geometry. turbulence environment &

structural dynamic properties (mass, stiffness, damping)

+

Page 7: Design of Slender Tall Buildings for Wind & Earthquake - CEE

� For many tall & slender buildings cross wind response can govern loading & acceleration.

� Wind codes generally cover along-wind response based on the Gust Factor Approach –but little guidance on cross-wind & torsional responses.

Structural Design Challenges for Tall Buildings

Wind

� EN 1991-1-4 states that for slender buildings (h/d > 4), Wind Tunnel Studies are necessary if

� distance between buildings is < 25 x d

� natural frequency < 1 Hz.

� BCA guidelines: H > 200m or f < 0.2Hz

� Prediction of building dynamic properties: natural frequencies, mode shapes & damping

have a great effect on the predicted wind loads & accelerations.

Page 8: Design of Slender Tall Buildings for Wind & Earthquake - CEE

� As an engineer, there are a number of approaches to minimize cross-wind response

� orientation

� setbacks, varying cross-section

� softened corners

� twisting, tapering

� introducing porosity

Structural Design Challenges for Tall Buildings

Wind

Page 9: Design of Slender Tall Buildings for Wind & Earthquake - CEE

� Tall buildings design often driven by occupant comfort criteria, i.e., limits to lateral acceleration

� Two conditions are generally important

� alarm caused by large motions under occasional

strong winds

� annoyance caused by perceptible motions on a regular basis - more important

� Solutions include stiffening the building, increasing mass

or use of supplemental damping.

Structural Design Challenges for Tall Buildings

Occupant Comfort

US Practice, Office

US Practice, Residential

ISO, Office

ISO, Residential

Page 10: Design of Slender Tall Buildings for Wind & Earthquake - CEE

� Many codes specify (& some provide guidelines) for a deflection limit of h/400 ~ h/600.

� Drifts can be based on winds of appropriate return

period - generally between 10 to 25 year return period winds.

� Story drifts have two components:

� Rigid body displacement

� Due to rotation of the building as a whole

� No damage

� Racking (shear) deformation

� Angular in-plane deformation

� Creates damage in walls and cladding

� Limit can be reviewed if damage to non-structural elements can be prevented, especially the façade, & lift performance is not affected.

Structural Design Challenges for Tall Buildings

Drift

tall & flexible

short & stiff

Page 11: Design of Slender Tall Buildings for Wind & Earthquake - CEE

� Differential shortening of vertical elements need

special consideration.

� Initial position of slabs can be affected with time - affecting partitions, mechanical equipment, cladding, finishes, etc.

� Mitigation options include appropriate stiffness

proportioning, choice of material, vertical cambering, etc..

Structural Design Challenges for Tall Buildings

Differential Shortening

High Performance

Grade 80 concrete

-30

-25

-20

-15

-10

-5

00 20 40 60 80

Column Elastic shortening

Column Creep shortening

Column Total shortening

Nearby Wall Total Shortening

Page 12: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Structural Design Challenges for Tall Buildings

Robustness

Which system is better?

Same strength & deformation capacity

What is the impact of premature loss of one element?

Page 13: Design of Slender Tall Buildings for Wind & Earthquake - CEE

� Important to consider construction

sequence & schedules in analysis to capture effects of:

� compressive shortening,

� creep & shrinkage, &

� any locked in stresses from transfer beams, outrigger systems, stiffer elements

� Becomes more complex on non-

symmetric structures where the axial shortening can cause floors to twist and tilt under self weight.

Structural Design Challenges for Tall Buildings

Sequential Analysis

Page 14: Design of Slender Tall Buildings for Wind & Earthquake - CEE

� Tall buildings are big budget projects – small savings per sq. m can become large amounts of money.

� Efficiency & economy are not defined by codes.

� Custom programs & scripts required to interface directly with commercial structural analysis packages to rapidly and efficiently establish optimum element sizes.

Structural Design Challenges for Tall Buildings

Structural Optimization

Page 15: Design of Slender Tall Buildings for Wind & Earthquake - CEE

� Settlement control critical for tall buildings to prevent tilt.

� Soil – structure interaction analysis may be required for accurate determination of foundation flexibility.

� Thick pile rafts minimize differential settlements.

Structural Design Challenges for Tall Buildings

Foundation Settlements

-100

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

0 20 40 60 80 100 120

Se

ttle

me

nt

(mm

)

Lateral coordinate (m)

Along B-B

Along B-B

Along Max gradient segment (green line):

Max differential settlement = 33.3 - 16.1 = 17.2 mm

Span = 102 - 73 = 29 m

So, differential distortion ratio = 17.2mm / 29,000mm = 1 : 1680 --> OK!

Page 16: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Structural Systems for Tall Buildings

02

Page 17: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Interior StructuresCourtesy : Architectural Science Review

Dual systems - shear wall–frame interaction for effective resistance of lateral load

Single component resisting systems

Effectively resists bending by exterior columns connected to outriggers extended from the core

� Interior Structures: single / dual component planar assemblies in 2 principal directions.

Structural Systems for Tall Buildings

Page 18: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Exterior Structures Courtesy : Architectural Science Review

� Exterior Structures: effectively resist lateral loads by systems at building perimeter

Structural Systems for Tall Buildings

Page 19: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Structural Systems for Tall Buildings

Page 20: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Dual System: RC Core + Perimeter Frames

� Efficient system using

� Central Services Core as the primary system

� Coupled with the Perimeter Frame for additional stiffness

� Generally economical up to 50 ~ 60 stories.

Marina Bay Financial Centre, Singapore

Per. Columns

Core

Semi-Precast Slab

PT Band Beams

RC Spandrel Beams

Shear sway Cantilever sway

H = 245m

50 storey

H = 186m

33 storey

Structural Systems for Tall Buildings

Page 21: Design of Slender Tall Buildings for Wind & Earthquake - CEE

� Extremely efficient system: outriggers engage perimeter columns & reduce core overturning moment.

� Architecturally unobtrusive since outriggers are located at mechanical floor & roof.

� Exterior column spacing meets aesthetic & functional requirements, unlike tube systems.

One Raffles Quay, Singapore

H/D = 6.5

50 StoreyH = 245m

Core + Outrigger + Belt Truss

Structural Systems for Tall Buildings

Page 22: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Four Seasons Place, KL, Malaysia

75 storeyH = 342mH/D=12.5

Po

diu

mH

ote

lR

esid

en

tia

l

� Innovative system to address extreme slenderness.

� Coupled walls extend over entire depth of floor plate to resist overturning moment & shear at every floor.

Coupled Outrigger Shear Walls

Structural Systems for Tall Buildings

Page 23: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Tornado Tower, Doha, Qatar

� Conceived to integrate with architectural form.

� Extremely efficient “exterior structure” suitable for up to 100+ stories.

� Variant of tubular systems & exterior braced frames.

� Carries gravity & lateral forces in a distributive and uniform manner. .

Effective because they

carry shear by axial

action of the diagonal

members (less shear

deformation).

Joints are complicated

52 storey, H = 200m

Diagrid

Structural Systems for Tall Buildings

Page 24: Design of Slender Tall Buildings for Wind & Earthquake - CEE

(23m)

(45m)

Overturning

Moment

� Towers with large mass eccentricity - weight sensitive & large movements.

� Long-term serviceability challenges.

� Structural System: Shear Wall + Rigid Frame + Outriggers + Belt Truss + Core Coupling Truss + Internal Braced Truss

�Atrium Braced Truss

L36 �Coupling Truss�Outrigger Truss�Belt Truss

L12 �Outrigger Truss�Belt Truss

Belt TrussesOutrigger Trusses

79 storey, H = 351m

65 storey, H = 305m

52 storey, H = 251m

Signature Tower, Dubai, UAE

Hybrid

Structural Systems for Tall Buildings

Page 25: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Key Considerations for Seismic Design

03

Page 26: Design of Slender Tall Buildings for Wind & Earthquake - CEE

� Seismic design philosophy focuses on safety rather then comfort.

� For Design Level Earthquakes, structures should be able to resist:

� Minor shaking with no damage

� Moderate shaking with no severe structural damage

� Maximum design level shaking with structural damage but without collapse

� Tall or small ? Which is safer?

Source: FEMA

Mexico City Earthquake, 1985

Seismic Design Considerations

Page 27: Design of Slender Tall Buildings for Wind & Earthquake - CEE

� Torsional Irregularity: Unbalanced Resistance

Plan Conditions Resulting Failure Patterns

� Re-Entrant Corners

� Diaphragm Eccentricity

� Non-parallel LFRS

� Out-of-Plane Offsets

Source: FEMA

Seismic Design Considerations

Page 28: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Vertical Conditions Resulting Failure Patterns

� Stiffness Irregularity: Soft Story

� Mass Irregularity

� Geometric Irregularity

� In-Plane Irregularity in LFRS

� Capacity Discontinuity: Weak Story

Source: FEMA

Seismic Design Considerations

Page 29: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Overview of BC3

04

Page 30: Design of Slender Tall Buildings for Wind & Earthquake - CEE

• Seismic requirement in Singapore from 1 Apr 2015

Overview of BC3

Source: Pappin et. al.

Page 31: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Building height, H > 20m?

NSeismic Action need not be considered in design

• Ordinary building on Ground Type Class “D” or “S1”, or• Special building on Ground Type Class “C”, “D” or “S1”

• Drift limitation check according to Clause 7 • Minimum structural separation check according to Clause 8

Seismic Action need not be considered in design

Ground Type within building footprint determined according to Clause 2

Y

NY

Seismic Action determined according to Clause 3 & Clause 4, using where appropriate, either• Lateral Force Analysis Method according to Clause 4.4, or • Modal Response Spectrum Analysis Method according to Clause 4.5

Building analyzed according to combination of actions in Clause 5, andFoundation design carried out according to Clause 6

Overview of BC3

Design Flowchart

Page 32: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Building classification Importance

Factor γl

Ground Type

B C D S1

Ordinary Building

All other than “Special

buildings” below1.0 - - Y Y

Special Building

• hospitals

• fire stations

• civil defense installations

• government offices

• institutional building

1.4 - Y Y Y

Building H > 20m

Overview of BC3

Definitions

Page 33: Design of Slender Tall Buildings for Wind & Earthquake - CEE

T (sec)

Spectral Acceleration

����� (%g)

T

(sec)

Spectral Acceleration

����� (%g)

0.0 4.50 1.8 10.00

0.1 5.25 2.0 9.00

0.2 6.00 2.2 8.18

0.3 6.75 2.4 7.50

0.4 7.50 2.7 6.67

0.5 8.25 3.0 6.00

0.6 9.00 3.5 5.14

0.7 9.75 4.0 4.50

0.8 10.50 4.6 3.91

0.9 11.25 5.2 3.06

1.0 11.25 6.0 2.30

1.1 11.25 7.0 1.69

1.2 11.25 8.0 1.29

1.4 11.25 9.0 1.02

1.6 11.25 10.0 0.83

T (sec)

Spectral Acceleration

�� ��� (%g)

T

(sec)

Spectral Acceleration

�� ��� (%g)

0.0 2.88 1.8 4.40

0.1 3.96 2.0 3.96

0.2 5.04 2.2 3.60

0.3 6.12 2.4 3.30

0.4 7.20 2.7 2.93

0.5 7.20 3.0 2.64

0.6 7.20 3.5 2.26

0.7 7.20 4.0 1.98

0.8 7.20 4.6 1.72

0.9 7.20 5.2 1.52

1.0 7.20 6.0 1.32

1.1 7.20 7.0 1.13

1.2 6.60 8.0 0.99

1.4 6.09 9.0 0.88

1.6 4.95 10.0 0.79

T (sec)

Spectral Acceleration

����� (%g)

T

(sec)

Spectral Acceleration

����� (%g)

0.0 5.76 1.8 14.40

0.1 6.30 2.0 14.40

0.2 6.84 2.2 14.40

0.3 7.38 2.4 14.40

0.4 7.92 2.7 11.38

0.5 8.46 3.0 9.22

0.6 9.00 3.5 6.77

0.7 9.54 4.0 5.18

0.8 10.08 4.6 3.92

0.9 10.62 5.2 3.07

1.0 11.16 6.0 2.30

1.1 11.70 7.0 1.69

1.2 12.24 8.0 1.30

1.4 12.78 9.0 1.02

1.6 14.40 10.0 0.83

Ground Type D Ground Type C Ground Type S1

Overview of BC3

Design Spectra

Page 34: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Overview of BC3

Design Example

Page 35: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Overview of BC3

Modal Response Spectrum Analysis Method (Para* 4.5)

� The intent of a more rigorous dynamic analysis approach is to more accurately capture the vertical distribution of forces along the height of the building. The steps for a dynamic analysis are summarized below.� Solve for the building’s period and mode shapes.� Ensure sufficient modes are used in the dynamic analysis by inspecting the

cumulative modal participation.� Determine base shears obtained through response spectrum in each direction

under consideration.

Determine Design Spectrum (Para* 3.2)

Page 36: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Overview of BC3

Modal Response Spectrum Analysis

A response spectrum analysis is then run in two orthogonal directions.

Page 37: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Overview of BC3

Modal Response Spectrum Analysis

Page 38: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Overview of BC3

Required Combinations of Actions (Load Combinations) (Para* 5.2)

Page 39: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Overview of BC3

Building Response

Page 40: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Case Studies

05

Page 41: Design of Slender Tall Buildings for Wind & Earthquake - CEE

The Sail @ Marina BaySingapore245m, 70 Story, 2008ConcreteResidential

Capital PlazaAbu Dhabi210m, 45 Story2012Concrete Residential, Hotel & Office

WTC IIJakarta, Indonesia160m, 30Story, 2012Composite Office

Ocean HeightsDubai310m, 82 Story2010ConcreteResidential

Case Studies

Page 42: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Nurol Life TowerTurkey250m, 60 Story, Under constructionCompositeResidential & Office

IFC ISGYO Office TowerTurkey111m, 27 Story, Under constructionComposite Office

Izmir Ova Centre,Turkey112m, 27 Story, Under constructionComposite Office

Thamrin Nine, Jakarta, Indonesia325m, 71 Story, Under constructionCompositeOffice & Hotel

Case Studies

Page 43: Design of Slender Tall Buildings for Wind & Earthquake - CEE

245m

� Two residential towers, 70 (245m) & 63 (216m) story.

� Towers have extreme slenderness ≈ 13

� Unique coupled-outrigger-shear wall structural system.

� Seismic design, super high strength concrete & unique strut-free retention system.

600 x 650

Spandrel

Beam

600 x 1000

Spandrel Col

170

semi Pre-cast slab

650

Main Shear

walls

300

Lift/Stair Walls

The Sail @ Marina Bay, Singapore

Case Studies

Page 44: Design of Slender Tall Buildings for Wind & Earthquake - CEE

T3 = 4.9sT2 = 5.5sT1 = 6.4s

Building

Dynamic PropertiesModal Analysis

Select Structure System & Materials

Lateral Loads (wind,

seismic), WTT

Building Performance/Strength

(Seismic Design to UBC 97)

Dynamic Analysis

(Response Spectrum Analysis)

� Seismic design adopted for enhanced safety & robustness

The Sail @ Marina Bay, Singapore

Case Studies

0 100 200 300 400 500

0

38

69

100

131

162

193

224

Code CP3

Wind Tunnel Test

Height (m)

Page 45: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Seismic Zone Zone Factor, Z Base Shear, V

Zone 2A 0.15g

2.4% W *

(with special detailing)

� Seismic Base Shear (V) depends on

� Zone (Z), Soil Profile (S), Structural Framing (R), Importance (I), Time Period (T) &

Weight (W)

� (0.11Ca I) W ≤ V = (Cv I / R T) W ≤ (2.5 Ca I / R) W , where

• Z represents expected ground acceleration at bedrock

• Ca & Cv are coefficients depending on Soil Profile and Zone

*Governed by minimum load required by code

Seismic Design to UBC 97

The Sail @ Marina Bay, Singapore

Case Studies

Page 46: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Structural Performance Indicators Tower 1 (245m)

Fundamental Period 6.4 secs

Building Acceleration 14. 1 milli-g

Inter-storey Drift under Wind h / 550

Inter-storey Drift under Seismic h / 280 (elastic), h / 70 (in-elastic)

Tower 1 acceleration sensors triggered by Sumatra EQ on 11 April 2012, 4:56PM

660 mm

1180 mm

330 mm

580 mm

T1: Seismic Displacement T1: Wind Displacement

Coupled Walls

Uncoupled Walls

Coupled Walls

Uncoupled Walls

Shear Wall Boundary Elements

Frame Members

Wall Coupling Beams

� ≈ 60% higher loads

� Special detailing

The Sail @ Marina Bay, Singapore

Case Studies

Page 47: Design of Slender Tall Buildings for Wind & Earthquake - CEE

� The 75-storey, 342m tower will be 2nd tallest building in Malaysia when completed in 2017.

� Challenging project due to 12.5 slenderness ratio.

� WT studies revealed significant wake vortices and strong cross wind effects.

342.5mFour Seasons Place, KL, Malaysia

Case Studies

Page 48: Design of Slender Tall Buildings for Wind & Earthquake - CEE

� An innovative lateral load resisting system was devised incorporating

� suitably located fin walls � two levels of concrete outrigger and

perimeter belt walls, � all coupled with the central core-walls.

Ty = 10.1s Tx = 6.4s Tr = 6.0s

Four Seasons Place, KL, Malaysia

Case Studies

Page 49: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Structural Performance

0

50

100

150

200

250

300

350

0 1000

Ele

vati

on

(m

)

Lateral Load (kN)

0 20000 40000 60000

Story Shear (kN)

0 5000 10000

Story Moment (MNm)

0 0.001 0.002 0.003

Story Drift Ratio

0.0000 0.0050 0.0100

Story Drift Ratio

Wind

Notional

Seismic

Four Seasons Place, KL, Malaysia

Case Studies

Page 50: Design of Slender Tall Buildings for Wind & Earthquake - CEE

� The 360,000m2 mixed use development comprising 4

tall Towers is located in the central business district on

Jalan Thamrin, Jakarta.

� The 71-storey, 325m tower will be the tallest building

in Jakarta when completed in 2018.

Thamrin Nine, Jakarta, Indonesia

Case Studies 325m

Page 51: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Ty = 7.2s Tx = 6.8s Tr = 3.2s

RC Walls/Columns/Beams/Slabs

Outriggers & Belt Trusses

Structural System

Thamrin Nine, Jakarta, Indonesia

Case Studies

Page 52: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Seismic Parameters Values Remarks

Site Classification D Medium hard soil.

Sds , Sd1 0.57g, 0.36gSpectral response acceleration parameters at short and 1 second periods

Importance Factor I = 1.25 For general buildings & structures

Response Modification Coefficient

R =7Ductile RC shear walls with special moment resisting frames

Risk Category III

SNI-02-1726-2012/ ASCE 7 (2010)

Seismic Building Drift

Seismic Design Parameters

Thamrin Nine, Jakarta, Indonesia

Case Studies

Page 53: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Structural Performance

0

50

100

150

200

250

300

350

0 2000 4000

Ele

vati

on

(m

)

Lateral Load (kN)

0 50000 100000

Story Shear (kN)

0.00E+00 1.00E+07 2.00E+07

Story Moment (kN-m)

0 0.002 0.004

Story Drift

0 0.002 0.004

Story Drift

Thamrin Nine, Jakarta, Indonesia

Case Studies

Wind

Seismic

Page 54: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Non-Linear Static Push-Over Analysis

Thamrin Nine, Jakarta, Indonesia

Case Studies

Page 55: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Curvilinear Form + Large Inclinations + Atrium Voids Unique Engineering Challenge

(23m)

(23m)(45m)

45m39m305m

49.1m

36.4m

248m

Overturning Moment

0 m

� Lateral effect due to gravity loads

> 2 times design wind load

≈ Zone 1 EQ

� All columns & internal walls curved

� Atrium voids throughout height

� Extremely weight sensitive

� Large building movements

Signature Towers, Dubai

Case Studies

Page 56: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L4Atrium Void

Atrium Void

Signature Towers, Dubai

Case Studies

Page 57: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L7

Signature Towers, Dubai

Case Studies

Page 58: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L10

Signature Towers, Dubai

Case Studies

Page 59: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L12A

Signature Towers, Dubai

Case Studies

Page 60: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L17

Signature Towers, Dubai

Case Studies

Page 61: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L20

Signature Towers, Dubai

Case Studies

Page 62: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L23

Signature Towers, Dubai

Case Studies

Page 63: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L26

Signature Towers, Dubai

Case Studies

Page 64: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L29

Signature Towers, Dubai

Case Studies

Page 65: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L32

Signature Towers, Dubai

Case Studies

Page 66: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L34

Signature Towers, Dubai

Case Studies

Page 67: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L36A

Signature Towers, Dubai

Case Studies

Page 68: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L40

Signature Towers, Dubai

Case Studies

Page 69: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L43

Signature Towers, Dubai

Case Studies

Page 70: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L46

Signature Towers, Dubai

Case Studies

Page 71: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L49

Signature Towers, Dubai

Case Studies

Page 72: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L50

Signature Towers, Dubai

Case Studies

Page 73: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L54

Signature Towers, Dubai

Case Studies

Page 74: Design of Slender Tall Buildings for Wind & Earthquake - CEE

L56

Signature Towers, Dubai

Case Studies

Page 75: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Un-deformed Shape Self-WT Drift Wind Load Drift Earth-Quake Drift

360mm 160mm 800mmH/380H/1890H/840

Signature Towers, Dubai

Case Studies

Page 76: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Comparison of Wind & Seismic Effects

06

Page 77: Design of Slender Tall Buildings for Wind & Earthquake - CEE

BS-6399-2 (ult)

EN 1991-1-4 +G.I. (ult)

heig

ht, m

heig

ht, m

Force (kN) Force (kN)

Notional Load

RC building,

L x W x H =

40m x 40m x 100m / 200m

Notional Load + G.I.

0

50

100

150

200

250

0 300 600

0

50

100

150

200

250

0 300 600

Comparison of Lateral LoadsUltimate Force

Page 78: Design of Slender Tall Buildings for Wind & Earthquake - CEE

0

50

100

150

200

250

0 1500000 3000000

BS-6399-2 (ult)

EN 1991-1-4 +G.I. (ult)

he

igh

t, m

he

igh

t, m

Overturning Mom. (kN-m) Overturning Mom. (kN-m)

Notional Load

Notional Load + G.I.

0

50

100

150

200

250

0 500000 1000000

Comparison of Lateral LoadsUltimate Over Turning Moment

RC building,

L x W x H =

40m x 40m x 100m / 200m

Page 79: Design of Slender Tall Buildings for Wind & Earthquake - CEE
Page 80: Design of Slender Tall Buildings for Wind & Earthquake - CEE

BS-6399-2 (ult)

EN 1991-1-4 +G.I. (ult)

he

igh

t, m

he

igh

t, m

Force (kN)Force (kN)

Notional Load

Notional Load + G.I.

0

50

100

150

200

250

0 400 800

0

50

100

150

200

250

0 400 800

Comparison of Lateral LoadsUltimate Force

RC building,

L x W x H =

22m x 70m x 100m / 200m

Page 81: Design of Slender Tall Buildings for Wind & Earthquake - CEE

0

50

100

150

200

250

0 2000000 4000000

BS-6399-2 (ult)

EN 1991-1-4 +G.I. (ult)

heig

ht, m

heig

ht, m

Overturning Mom. (kN-m) Overturning Mom. (kN-m)

Notional Load

Notional Load + G.I.

0

50

100

150

200

250

0 500000 1000000

Comparison of Lateral LoadsUltimate Over Turning Moment

RC building,

L x W x H =

40m x 40m x 100m / 200m

Page 82: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Comparison of Lateral LoadsImpact of Seismic Loads

Page 83: Design of Slender Tall Buildings for Wind & Earthquake - CEE

0

50

100

150

200

250

0 250 500 7500

50

100

150

200

250

0 500 1000 1500 2000

heig

ht, m

heig

ht, m

Force (kN) Force (kN)

BS-6399-2 (ult)

EN 1991-1-4 +G.I. (ult)

Notional Load

BC3 Seismic + G.I.

(q = 1.5, Soil Type D)

Notional Load + G.I.

Comparison of Lateral LoadsUltimate Force

RC building,

L x W x H =

40m x 40m x 100m / 200m

Page 84: Design of Slender Tall Buildings for Wind & Earthquake - CEE

0

50

100

150

200

250

0 1000000 2000000 30000000

50

100

150

200

250

0 1000000 2000000

heig

ht, m

heig

ht, m

Overturning Mom. (kN-m)Overturning Mom. (kN-m)

BS-6399-2 (ult)

EN 1991-1-4 +G.I. (ult)

Notional Load

BC3 Seismic + G.I.

(q = 1.5, Soil Type D)

Notional Load + G.I.

Comparison of Lateral LoadsUltimate Over Turning Moment

RC building,

L x W x H =

40m x 40m x 100m / 200m

Page 85: Design of Slender Tall Buildings for Wind & Earthquake - CEE

0

50

100

150

200

250

0 250 500 7500

50

100

150

200

250

0 200 400 600 800

heig

ht, m

heig

ht, m

Force (kN)Force (kN)

BS-6399-2 (ult)

EN 1991-1-4 +G.I. (ult)

Notional Load

BC3 Seismic + G.I.

(q = 4.5, Soil Type D)

Notional Load + G.I.

Comparison of Lateral LoadsUltimate Force

RC building,

L x W x H =

40m x 40m x 100m / 200m

Page 86: Design of Slender Tall Buildings for Wind & Earthquake - CEE

0

50

100

150

200

250

0 1000000 2000000 30000000

50

100

150

200

250

0 200000 400000 600000 800000

heig

ht, m

heig

ht, m

Overturning Mom. (kN-m)Overturning Mom. (kN-m)

BS-6399-2 (ult)

EN 1991-1-4 +G.I. (ult)

Notional Load

BC3 Seismic + G.I.

(q = 4.5, Soil Type D)

Notional Load + G.I.

Comparison of Lateral LoadsUltimate Over Turning Moment

RC building,

L x W x H =

40m x 40m x 100m / 200m

Page 87: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Cost Comparison of Concrete vs. Composite Tall Building

07

Page 88: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Source: CTBUH

� 82% of the 100 tallest buildings are either concrete or composite.

Cost Comparison

Page 89: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Comparative Case Study of a Typical Tall Building in Singapore

Building Description

GFA: 85,000 m2

Height: 130m

No. of Floors: 30

Typ. Floor Height: 4.3m

Typ. Floor Area: 2800 m2

Clear Span: up to 15.5m

Lateral System: Dual System -

RC Core + Frames

RC Building Steel-Concrete Composite Building

Page 90: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Comparative Case Study of a Typical Tall Building in Singapore

RC Building RC Building RC Building RC Building –––– Typical ParametersTypical ParametersTypical ParametersTypical Parameters CompositeCompositeCompositeComposite Building Building Building Building ---- Typical ParametersTypical ParametersTypical ParametersTypical Parameters

Long Span PT Band Beam: 2400x 600 Deep Long Span Steel Beams: UB610 x 229 x 92

Short Span PT Band Beam: 2400x 550 Deep Short Span Steel Beams: UB610 x 229 x 113

Edge Beam: 500x600 Deep Edge Steel Beams: UB533 x 210 x 66

PT Slab Thickness: 200 Typical Slab: 130 on Re-Entrant Deck

Primary Core Wall Thickness: 350 Primary Core Wall Thickness: 300

Secondary Core Wall Thickness: 250 Secondary Core Wall Thickness: 250

Columns : 1.0m x 1.0m Columns : 0.8m dia. CHS

Framing Systems Considered

Floor Framing Graphics

9m

15.5m13.5m

12.5m

9m

15.5m13.5m

12.5m

Page 91: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Comparative Case Study of a Typical Tall Building in Singapore

Design Criteria

Gravity Loading:

Dead Load (DL) : Self-weight of elements

Superimposed Dead Load (SDL) : 1.5 kPa

Live Load (LL) : 3.5 kPa + 1 kPa for Partitions = 4.5 kPa Total

Cladding (SDL) : 1.0 kPa (on elevation)

Lateral Loading:

Wind Speed : 22m/s Mean Hourly, 50-year Return Period

Wind Load Pressure : Max Pressure ~ 1.3 kPa

Seismic : SS-EN 1998-1, BC3, q=1.5, Ground Type D

Deflections and Drift Parameters:

Interior Beams, Live Load : L / 250, 20 mm maximum

Interior Beams, Incremental Deflection : L / 350

Perimeter Beams, Live Load : L /500, 10 mm maximum

Wind Inter-story Drift : H / 500

Floor Vibrations and Acceleration: : Frequency ≥ 4 Hz & / or Acceleration ≤ 0.5%g

Page 92: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Comparative Case Study of a Typical Tall Building in Singapore

Building Dynamic Properties

T1 = 3.5 s T2 = 3.1 sRC Building

Composite BuildingT1 = 3.2 s T2 = 2.9 s

Page 93: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Comparative Case Study of a Typical Tall Building in Singapore

Building Performance Comparison

RC Building:

Veq1 = 3.41%*W = 35.9 MN

Veq2 = 3.95%*W = 41.6 MN

Sd (T) = Se (T). γl

q

[γl = 1.0, q=1.5]

0

5

10

15

20

25

30

35

0 1000 2000 3000 4000

Sto

rey

Lateral Storey Forces

Wind–RC/Composite Seismic–RC

Seismic–Composite

Composite Building:

Veq1 = 3.81%*W = 24.9 MN

Veq2 = 4.05%*W = 26.5 MN

0

5

10

15

20

25

30

35

-200000 800000 1800000 2800000 3800000

Overturning Moment

Seismic-Composite

Seismic-RC

Wind–RC/Composite

0

5

10

15

20

25

30

35

0 10 20 30

Sto

rey

Inter-storey Drift

Seismic-RC

Seismic–Composite

Wind–Composite

Δ=

h / (

20

0.v

.q)

Δ=

h / 5

00

Wind-RC

Page 94: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Comparative Case Study of a Typical Tall Building in Singapore

Member Envelope Forces

RC Building

Composite Building

Page 95: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Comparative Case Study of a Typical Tall Building in Singapore

Costing Assumptions:Pricing information was collated & verified through a combination of local sources (based on 2013 prices)

Baseline Unit Costs (“All-in,” incl. labour)

Concrete Grade (fcu) Cost (S$/m3)

30 $ 155

40 $ 160

50 $ 165

60 $ 170

Rebar Cost (S$/T) $ 1,500

Post-tensioning (S$/T) $ 6,000

Formwork (S$/m2) $ 35

Structural Steel incl. studs (S$/T) $ 5,000

Metal Deck (S$/m2)

1 mm Bondek $ 40

Steel Fireproofing (S$/m2) $ 25

Foundation Costs (S$/ ton / m ) $ 0.60

Material Cost Information Courtesy of :• Langdon & Seah

• Bluescope Lysaght

• Hyundai E&C

• Yongnam

Page 96: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Comparative Case Study of a Typical Tall Building in Singapore

Building Weight (Normalized; including imposed loads)

0.00

0.10

0.20

0.30

0.40

0.50

0.60

0.70

0.80

0.90

1.00

RC Building Steel-Concrete Composite Building

1.00

0.71

No

rma

lize

d B

uil

din

g W

eig

ht

Page 97: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Comparative Case Study of a Typical Tall Building in Singapore

Concrete Costs (Normalized; excluding rebar & PT)

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

RC Building Steel-Concrete Composite

Building

1.0

0.5

No

rma

lize

d C

on

cre

te C

ost

s

Page 98: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Comparative Case Study of a Typical Tall Building in Singapore

Rebar and Post-tensioning Costs (Normalized)

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

RC Building Steel-Concrete Composite Building

1.0

0.3

No

rma

lize

d R

eb

ar

& P

T C

ost

s

Page 99: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Comparative Case Study of a Typical Tall Building in Singapore

Structural Steel Costs (Normalized; including Decking and FP)

0.0

0.5

1.0

1.5

2.0

2.5

RC Building Steel-Concrete Composite Building

0.0

2.3N

orm

ali

zed

Ste

el

Co

sts

Page 100: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Comparative Case Study of a Typical Tall Building in Singapore

Foundation Costs (Normalized)

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

RC Building Steel-Concrete Composite Building

1.0

0.7

Fou

nd

ati

on

Co

sts

Page 101: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Comparative Case Study of a Typical Tall Building in Singapore

Total Structural ‘Material’ Costs (Normalized)

0.00

0.20

0.40

0.60

0.80

1.00

1.20

1.40

RC Building Steel-Concrete Composite Building

1.00

1.24N

orm

ali

zed

Str

uct

ura

l Co

sts

Page 102: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Comparative Case Study of a Typical Tall Building in Singapore

Total Structural ‘Material‘ Costs (Normalized)

0.00

0.20

0.40

0.60

0.80

1.00

1.20

1.40

RC Building Composite With Seismic Composite Without Seismic

1.00

1.24 1.30N

orm

ali

zed

Str

uct

ura

l Co

sts

This cost premium is not unique. It will vary based on location, material rates, building type / form and structural design parameters.

Page 103: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Comparative Case Study of a Typical Tall Building in Singapore

Total Project Construction Costs (Normalized)

-

0

0

1

1

1

1

RC Building Steel-Concrete Composite Building

1 1.03

No

rma

lize

d P

roje

ct C

on

stru

ctio

n C

ost

s

Page 104: Design of Slender Tall Buildings for Wind & Earthquake - CEE

The Big Picture ……..

Page 105: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Other Costs and Revenues

PROJECT COSTS

GFA = 85,000 sq-mLand Cost = $19,000 per sq-m of GFALegal Fee & Stamp Duty = 4% of land costTotal Project Duration (including Design Period)= 33 monthsProperty Tax = 0.5% x land cost x duration)($)Associated Costs (Prof. & Site Supervision Fee) = ~ 8% of Total Construction CostMarketing & Advertisement = ~ 5% of Total Construction CostGST = 7% of Construction & Associated CostsInterest of Financing Cost for Land = 5% of Land Cost, Legal Fee & Property TaxInterest of Financing During Construction = 5% of Construction & Associated Costs x 0.5

RENTAL RETURN + PRELIMINARIESNet Efficiency= 80%Occupancy Rate= 80%Rental Rate $$/sq-ft/month= $12 per sq-ft per monthPreliminaries / month = 10% of Total Construction Cost

The Big Picture ……..

Page 106: Design of Slender Tall Buildings for Wind & Earthquake - CEE

The Big Picture ……..

Total Development Construction Costs (Normalized)

0

0.2

0.4

0.6

0.8

1

1.2

RC Building Steel-Concrete Composite Building

1 1.005

No

rma

lize

d S

tru

ctu

ral C

ost

s

Page 107: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Total Project Construction / Development Costs (Normalized)

1.03

0.986

0.945

0.904

0.864

1.005

0.996 0.986 0.977 0.967

0.6

0.65

0.7

0.75

0.8

0.85

0.9

0.95

1

1.05

0 1 2 3 4

RC Building

Composite – Adjusted Total Development Cost

Composite –Adjusted Total Construction Cost

Savings in Construction Time (months)

Norm

aliz

ed C

ots

The Big Picture ……..

Construction Time Saving (Months)

No

rmal

ized

Co

st

Page 108: Design of Slender Tall Buildings for Wind & Earthquake - CEE

� Besides productivity & costs what are the other intangible benefits of utilizing steel?

� Higher quality

� Lesser maintenance

� More functional spaces

� Flexibility to adaptation

� Higher sustainability

� Better performance under seismic actions

Composite Construction Benefits

One Raffles Link

One Raffles Quay

Page 109: Design of Slender Tall Buildings for Wind & Earthquake - CEE

Concluding Remarks

08

Page 110: Design of Slender Tall Buildings for Wind & Earthquake - CEE

� Tall buildings present special challenges to design & construction.

� The challenges from wind and seismic loads can be addressed through innovative design concepts.

� Composite buildings offer far higher potential for greater productivity & hence lower costs.

� Moving forward, more complex & taller buildings will be conceived & constructed.

� Structural engineers have the biggest contribution to make in making buildings safe & economical.

In Summary

How will these future tall buildings be designed & constructed?

The choice is yours ………