Design of Connections

download Design of Connections

of 24

Transcript of Design of Connections

  • 7/29/2019 Design of Connections

    1/24

    DESIGN OF CONNECTIONS FOR STEEL

    ELEMENTS ACCORDING TO ENV 1993-1-8

  • 7/29/2019 Design of Connections

    2/24

    WEB PANEL

    IN SHEAR

    CONNECTED

    PARTS

    Parts of a beam-to-column connection

    Major axis joint configurationJoint configuration

  • 7/29/2019 Design of Connections

    3/24

    PARTIAL SAFETY FACTORS

    Valorile numerice ale coeficientilor de siguranta pot fi impusi la nivelul normelor nationale de calcul.

    Valorile recomandate sunt: M2=1,25; M3=1,25; M3,ser=1,1; M4=1,0; M5=1,0;M6,ser=1,0; M7=1,1

  • 7/29/2019 Design of Connections

    4/24

    JOINTS RESISTANCE

    DESIGN HYPOTHESES

    The design resistance of the connection is determined through the individual design resistance of

    its principal component parts.

    The design of the connections may consider either a linear elastic analysis of a elasto-plasticanalysis.

    Generally, when in a connection subjected to shear meet fasteners with different stiffness, the

    fasteners with the a greater stiffness will take this force (exceptions are presented in this code)

    Connection design is based on a realistic evaluation of the distribution of forces and moments

    inside a joint. This evaluation calls on the hypotheses:

    -Internal forces and moments are the result of joint resolution under external efforts;

    - Every element as component of the connection is able to cope with these external efforts;

    -After the distribution of internal forces and moments, the deformations resulted will not exceedthe capacity of deformation of bolts or welding between component parts of the connection;

    -The distribution of the efforts to the component parts of the joint must be realistic evaluated

    based on the relative stiffness of the elements of the connection;

    -Deformations associated with any design model based on elasto -plastic analysis take into

    account the rotation of the rigid body and/or any possible in plane deformations; the same case is

    considered when the model is a physical one, tested in laboratory (according to ENV 1990)

  • 7/29/2019 Design of Connections

    5/24

    CONNECTIONS SUBJECTED TO SHOCK,

    VIBRATIONS AND ALTERNANT SOLICITATIONS

    METHODS FOR CONNECTING

    WELDING

    BOLTS WITH

    LOCKING DEVICES

    PRELOADED

    BOLTS

    INJECTED

    FASTENERS

    OTHER TYPES

    OF FASTENERS

    RIVETS

    Anytime when the connection must be prevented from slipping, preloaded bolts will be

    used, category B or C, as well as fit bolts, rivets or welding.

    Parts of bracing system that take wind action or are used for insuring the general

    stability will use fasteners in category A.

  • 7/29/2019 Design of Connections

    6/24

    ECCENTRICITY AT INTERSECTIONS

    In joints where components will be eccentrically connected, bending moments along with axial

    forces will be considered, excepting when this is not a relevant case, according to pt. 5.15,ENV 1993-1-8 and Annex BB 1.2, ENV 1993-1-1

    Setting out lines in a chord-to-internal member connection

  • 7/29/2019 Design of Connections

    7/24

    BOLTED OR RIVETED CONNECTIONS

    BOLTS, NUTS AND WASHERS

    Reference standards: group 4, 7 and 6, ENV 1993-1-8

    Classes of the bolts, according to ENV 1993-1-8;

    Yield strength fyb and ultimate tensile strength fub for bolts in classes 4.6, 5.6, 6.6, 6.8, 8.8 si

    10.9 presented in the table below will be adopted as characteristic values during the proces of

    design and verifications.

    Nominal values of limit yield strength fyb and of ultimate tensile strength

    fub for different classes of bolts

    ANCHOR (HOLD DOWN) BOLTS

    Grades in reference standards, groups 1 and 4, concrete reinforcing bars

    according to EN 10080 only if:

    Bolts subjected to shear will have the nominal yield strength under 640

    N/mm2 and those subjected to other kinds of stresses under 900 N/mm2

  • 7/29/2019 Design of Connections

    8/24

    CATEGORIES OF BOLTED CONNECTIONS

    I. Connections subjected to shear:

    Category A: Bearing type; classes 4.6 up to 10.9, no supplementary conditions imposed to

    the faces in contact and no preloading of the bolt are required. Design ultimate shear force in

    the bolt must not be exceeded by the design shear resistance, according to table and nor design

    bearing resistance according to tables also.

    Category B: Slip resistance in serviceability limit state: preloaded bolts for which the

    slipping under shear efforts must prevented from during the serviceability limit state; slip

    resistances are determined according to table and also, shear and bearing resistance forcesmust exceed the design shear force.

    Category C: Slip resistance in ultimate limit state: the conditions are identical with those

    imposed to B category but also, connections subjected to tension will be verified for the design

    plastic resistance of the net cross section in ultimate limit state , according to ENV 1993-1-1

    II. Connections subjected to tension:

    Category D: tensioned bolts not preloaded:classes 4.6 up to 10.9, often subjected toversatile tensile efforts (braces).

    Category E: preloaded bolts in tension: classes 8.8 and 10.9 of bolts for which the preloaded

    stress is checked according standard group 7.

  • 7/29/2019 Design of Connections

    9/24

    CATEGORIES OF BOLTED CONNECTIONS

    Category-verifications Criteria Observations

    Connections subjected to shear

    Type A

    Bearing resitance

    Fv,Ed Fv,Rd

    Fv,Ed Fb,Rd

    Bolts in classes 4.610.9 may be used,preloading is not necessary

    Type B

    Slip resitance under serviceabilitylimit state forces

    Fv,Ed, ser Fs,Rd, ser

    Fv,Ed Fv,Rd

    Fv,Ed Fb,Rd

    Bolts in classes 8.8 and 10.9 may be used,verifications for slip under limit state ofserviceability forces being necessary.

    Type CSlip resistance under ultimate

    limit state forces

    Fv,Ed Fs,Rd

    Fv,Ed Fb,Rd

    Fv,Ed Nnet,Rd

    Preloaded bolts in classes 8.8 or10.9, verificationsunder limit state of strength and stability beingapplied.

    Connections subjected to tension

    Type D

    Resistance under tensile forcesof non preloaded bolts

    Ft,Ed Ft,Rd

    Ft,Ed Bp,Rd

    Bolts in classes 4.610.9 may be used, they donot have to be preloaded; for the determination ofBp,Rd, see table.

    Type E

    Resistance under tensile forcesof preloaded bolts

    Ft,Ed Ft,Rd

    Ft,Ed Bp,Rd

    Classes 8.8. or 10.9 are used and for Bp,Rd the use

    of table is imposed

    Design tension force, Ft, Rd includes any force due to prying. For bolts in shear and tension see also tables.

  • 7/29/2019 Design of Connections

    10/24

    POSITIONING OF HOLES FOR BOLT AND RIVETS

    Distances and spacing Minimum Maximum

    Structures made from steels according to EN 10025with the exception of those made from steels

    according to EN 10025-5

    Structures made from steels accordingto EN 10025-5

    Steels exposed to weatheror other corrososive

    consitions

    Steels not exposed toweather or other

    corrososive consitions

    Steels used unprotected

    End distances e1 1,2d0 4t+40 mm max (8t ; 125 mm)

    Edge distances e2

    1,2d0

    4t+40 mm max (8t ; 125 mm)

    Distance e3

    in slotted holes 1,5d0

    4)

    Distance e4

    in slotted holes 1,5d0

    4)

    Spacing p1 2,2d0 min (14t ; 200 mm) min (14t ; 200 mm) min (14tmin ; 175 mm)

    Spacing p1,0

    min (14t ; 200 mm)

    Spacing p1,i

    min (28t ; 400 mm)

    Spacing P2

    5) 2,4d0

    min (14t ; 200 mm) min (14t ; 200 mm) min (14tmin

    ; 175 mm)

  • 7/29/2019 Design of Connections

    11/24

    1) Maximum values fore1, e2, p1, p2 are unlimited , excepting:

    -elements in compression, in order to avoid the loss of stabilityand corrosion;-elements exposed to tension in order to avoid corrosion.

    2) Buckling resistance of the steel plate between two holes isdetermined according to ENV 1993-1-1, using a buckling lengthequal with 0,6 pt; in the case whenpt/t

  • 7/29/2019 Design of Connections

    12/24

    a) Holes in parallel rows b) Staggered rows

    Holes in stagger : a)- members in compression; b)-members in tension. 1-end (edge) row; 2-

    internal row

    ab

    End (edge) distances for a slotted hole

  • 7/29/2019 Design of Connections

    13/24

    REZISTENTA DE CALCUL A DISPOZITIVELOR DE FIXARE INDIVIDUALE

    For fasteners subjected to shear and/or tension, see table ;

    For preloaded bolts, the design preload is determined with:

    Design resistance for shear is used for holes with nominal diameters having nominal tolerances in reference

    standards group 7;

    Bolts may be used in holes with tolerance up to 2 mm providing that Fb,Rd to be greater than Fv,Rd, and in

    addition for the classes 4.8, 5.8, 6.8, 8.8 and 10.9, Fv,Rd determined with the relationship in the table will be

    multiplied with 0,85;

    For fit bolts threaded part is not cut by the shear plane; the length of the threaded part including the bearing

    length should not exceed 1/3 of the thickness of the plate (see figure);

    Connections with one shear plane (lap joints) will be provided with washers under the head of the bolt and also

    under the nut and the design resistance in bearing will be limited to:

    Bolts in classes 8.8, 10.9 will be used with hardened nuts forlap joints with a single bolt or with a single row.

    Connections subjected to shear having compensation plates, according to figure, for which tp>1/3dnominal , Fv,Rd

    obtained from table will be amplified with:

    7

    7,0,

    M

    SubCdp

    AfF

    =

    2

    /5,1, MuRdb tdfF

    0,1:,38

    9

    += p

    p

    p buttd

    d

  • 7/29/2019 Design of Connections

    14/24

    Threaded portion of the shank in

    bearing lengths of fit bolts

    Lap joints with one single shear plane and one

    single row

    Fasteners through packings

    Packingplate

  • 7/29/2019 Design of Connections

    15/24

    Failure mode Bolts Rivets

    Design resistance for shear plane

    When shear plane cuts the threaded part of the shank (A is the crosssection):

    classes 4.6, 5.6 si 8.8.v=0,6

    classes 4.8, 5.8, 6.8 10.9v=0,5

    When shear plane cuts the part of the shank which is not threaded (A isthe gross cross section): v=0,6

    Bearing resistance

    ab=min (

    d; f

    ub/f

    u;1,0)

    In the direction of the load transfer, dwill be adopted as:

    -e1/3d

    0for the end row;

    -e1/3d

    0-1/4 for the internal row

    Normal to the direction of the load transfer k1 will be adopted as :

    -2,8e2/d

    0-1,7 ;2,5 for edge rows ;

    -1,4p2/d

    0-1,7 ;2,5 for internal rows

    Tension resistance

    For contersunk bolts k2

    =0,63

    Other cases k2=0,9

    Punching shear resistance

    Combined shear and tension resistance Any kind of verification is notnecessary

    2

    ,

    M

    ubvRdv

    AfF

    =

    2

    1

    ,

    M

    udRdb

    tdfkF

    =

    2

    2

    ,

    M

    subRdt

    AfkF

    =

    2

    0

    ,

    6,0

    M

    ur

    Rdt

    AfF

    =

    2

    0

    ,

    6,0

    M

    ur

    Rdv

    AfF

    =

    2

    6,0,

    M

    up

    Rdp

    fdtB

    =

    0,14,1

    ,

    ,

    ,

    ,+

    Rdt

    Edt

    Rdv

    Edv

    F

    F

    F

    F

    DESIGN RESISTANCES FOR INDIIDUAL FASTENERS SUBJECTED TO SHEAR OR/AND TENSION

  • 7/29/2019 Design of Connections

    16/24

    DESIGN RESISTANCES FOR INDIIDUAL FASTENERS SUBJECTED TO

    SHEAR OR/AND TENSION- SPECIFICATIONS

    1)- For oversized holesbearing resistance is 0,8 Fb,Rd from the one for normal sized holes; for slotted holes with the

    longitudinal slotted hole normal to the direction of the effort, the design bearing resistance is Rb,Rd.

    2)- Countersunk bolts :

    - Rb,Rd is determined based on the thickness of the plate, t , from which a deduction is made, equal with depth of the

    sunk;

    - Ft,Rd will be determined based on the angle and the depth of the sunk according to reference standars group 4;

    alternatively, Ft,Rd will be adjusted with the detail of the design;

    3)- When the effort in the bolt is no longer paralel with the edge, resistance for bearing will be determinedseparatelly for all the components paralel and normal to the edge.

  • 7/29/2019 Design of Connections

    17/24

    RESISTANCE OF GROUPS OF FASTENERS

    The total resistance of a group of bolts may be taken as an average between the resistances in bearing, Fb,Rd

    only if each of the individual resistances is greater than ,Fv,Rd. If not, the resitence of the whole gropu will be

    the sum of the individual resistances.

    If a spliced connection needs to be longer than 15 x bolt diameter both faces of the splice, shear resistance

    Fv,Rd of all the bolts will be reduced with a factor1,f:

    The values of this factor are : 0,75.1,0;

    The shear resistance Fv,Rd will not be reduced if the shear force is uniformly transferred along the

    connection (e.g., welded connection between web and flanges for a build up I section)

    Long spliced connection

  • 7/29/2019 Design of Connections

    18/24

    CONNECTIONS WITH HIGH STRENGTH BOLTS CLASSES 8.8. AND 10.9

    SLIP RESISTANCE

    For preloaded bolts in classes 8.8 and 10.9, slip resistance will be determined as it follows:

    where:

    ks- coefficient depending on the type of the hole, from table;

    n number of friction surfaces;

    - friction factor, experimentally determined, according to reference standards, group 7. Thepreloading force is controlled in group 4 of bolts; it is determined with the following relationship:

  • 7/29/2019 Design of Connections

    19/24

    Type (description) ks

    Bolts in normal holes 1,0

    Bolts in either oversized holes or short slotted holes with the axis ofthe slot perpendicular to the direction of load transfer

    0,85

    Bolts in long slotted holeswith the axis of the slot perpendicular tothe direction of load transfer

    0,7

    Bolts in short slotted holeswith the axis of the slot parallel to thedirection of load transfer

    0,76

    Bolts in short slotted holeswith the axis of the slot parallel to thedirection of load transfer

    0,63

    Values for the coefficent ks

    Friction classes of the surfaces(standards in reference group 7)

    A 0,5

    B 0,4

    C 0,3

    D 0,2

    NOTE: Testing and inspection of connections are presented in

    reference standards, group 7 The same reference standards classify other types of

    processing the surfaces of representative specimens Preparation of surfaces subjected to preloading consists

    in panting in several layers; these layers may affect intime the preloading force in the bolt

    Slip factor

  • 7/29/2019 Design of Connections

    20/24

    TENSION AND SHEAR OF PRELOADED BOLTS

    A slip resistant connection subjected to tension in ultimate limit state or serviceability limit state, Ft,Ed or Ft, Ed,ser

    and shear, Fv,Rd or Fv, Ed,ser, the resistance of the bolt will be diminished according to the relationship:

    Connection in B category:

    Connection in C category:

    NOTE:

    If in a connection subjected to bending moment the force of compression in contact area exceeds the tension force,

    no reduction is applied to the slipping resistance.

  • 7/29/2019 Design of Connections

    21/24

    ANGLES CONNECTED BY ONE LEG, OTHER MEMBERS CONNECTED

    UNSYMMETRICALLY SUBJECTED TO TENSION

  • 7/29/2019 Design of Connections

    22/24

    DEDUCTION OF FASTENERS HOLES

    A. DESIGN OF BLOCK TEARING: failure in shear at the row of bolts+ tensile rupture along the line of bolt holes on

    the tension face.

    Symmetric bolt group subjected to concentric loading design block tearing resistanceVeff,1,Rd

    where:

    Ant - net area in tension;

    Anv - net area in shear.

    Bolt group subjected to eccentric loading design block shear tearing resistanceVeff,2, Rd

    B. ANGLES CONNECTED BY ONE LEG, OTHER MEMBERS CONNECTED UNSYMMETRICALLY, SUBJECTED

    TO TENSION: the design resistance of either unsymmetrical members or symmetrical members connected

    unsymmetrical is affected by the distribution of spacing and end (edge) distances of bolts

    Single angle in tension with one row of bolts=concentrically loaded net section for which the design ultimate

    resistance is determined with:

  • 7/29/2019 Design of Connections

    23/24

    Block tearing of different types of connections subjected to shear and tension

    Angles connected by one leg

    Reduction factors depending on pitch p1;

    between limit values, interpolation is applied

  • 7/29/2019 Design of Connections

    24/24

    STRESS DISTRIBUTION BETWEEN BOLTS IN THE

    ULTIMATE STATE DESIGN

    1. In the connections subjected to bending moment the distribution of the internal efforts may be

    linear elastic or, plastic considering a status of equilibrium both with the resistance of thecomponents and with their ductility. Linear-elastic distribution is preferred in the case when:

    - bolts are in a C category connection;

    -blots are subjected to shear and for every bolt: F v,Rd