Design for IP21 and IP 31 protection.

13
ABB ENCLOSURES PROJECT ABB Trafo DDT ENERO.ppt 1 de Design for IP21 and IP 31 protection. Hole punching detail IP 31 IP 21

description

Design for IP21 and IP 31 protection. Hole punching detail. IP 21. IP 31. Design for IP23 and IP 33 protection. Rain protection detail. Exploded view. Wheels support and angular supports. Side bottom. Center bottom. Cable entry. Lower wall. Middle wall. Upper wall. Side wall. Roof. - PowerPoint PPT Presentation

Transcript of Design for IP21 and IP 31 protection.

Page 1: Design for IP21 and IP 31 protection.

ABB

ENCLOSURES PROJECT

ABB Trafo DDTENERO.ppt 1 de

Design for IP21 and

IP 31 protection.

Hole punching detail

IP 31

IP 21

Page 2: Design for IP21 and IP 31 protection.

ABB

ENCLOSURES PROJECT

ABB Trafo DDTENERO.ppt 2 de

Design for IP23 and

IP 33 protection.

b

60

c

a

45°

d

ba

45°

Lluvia 60º

Rain protection detail

Page 3: Design for IP21 and IP 31 protection.

ABB

ENCLOSURES PROJECT

ABB Trafo DDTENERO.ppt 3 de

TRANSFORMER

TRANSFORMER FOOT

CABLE ENTRY

ANGULAR SUPPORT

LOWER WALL

UPPER WALL

MIDDLE WALL

SIDE WALLS

ROOF

CENTER BOTTOM

WHEELS SUPPORT

SIDE BOTTOM

SIDE WALLS

Exploded view

Page 4: Design for IP21 and IP 31 protection.

ABB

ENCLOSURES PROJECT

ABB Trafo DDTENERO.ppt 4 de

Wheels support and

angular supports

Page 5: Design for IP21 and IP 31 protection.

ABB

ENCLOSURES PROJECT

ABB Trafo DDTENERO.ppt 5 de

Side bottom

Page 6: Design for IP21 and IP 31 protection.

ABB

ENCLOSURES PROJECT

ABB Trafo DDTENERO.ppt 6 de

Center bottom

Page 7: Design for IP21 and IP 31 protection.

ABB

ENCLOSURES PROJECT

ABB Trafo DDTENERO.ppt 7 de

Cable entry

Page 8: Design for IP21 and IP 31 protection.

ABB

ENCLOSURES PROJECT

ABB Trafo DDTENERO.ppt 8 de

Lower wall

Page 9: Design for IP21 and IP 31 protection.

ABB

ENCLOSURES PROJECT

ABB Trafo DDTENERO.ppt 9 de

Middle wall

Page 10: Design for IP21 and IP 31 protection.

ABB

ENCLOSURES PROJECT

ABB Trafo DDTENERO.ppt 10 de

Upper wall

Page 11: Design for IP21 and IP 31 protection.

ABB

ENCLOSURES PROJECT

ABB Trafo DDTENERO.ppt 11 de

Side wall

Page 12: Design for IP21 and IP 31 protection.

ABB

ENCLOSURES PROJECT

ABB Trafo DDTENERO.ppt 12 de

Roof

Page 13: Design for IP21 and IP 31 protection.

ABB

ENCLOSURES PROJECT

ABB Trafo DDTENERO.ppt 13 de

Detail of the union

between:

- Enclosure bottom

- Angular support

- Wheels support

Washer M8 DIN 9021Angular support

6

Bolt M8x20

Washer M8 DIN 9021

Lock nut M8 DIN 985

Nut M8

1.5

1 .5

Coil

Enclosure bottom

Wheels support

Bolt M8x25 DIN 603 (Rounded head)

Square hole 9x9

CoilClamps

Coil