Design Calculations

1
Design Calculations Length of line: - 2 Km Diameter: - 2 Inch Total Surface Area: D x π x L = 0.0512 x 3.14 x 2000 = 318.78 Say Total surface area to be protected 320 M² Current Density Chosen= 0.25mA/m² at 30º C OR 0.41mA/ m² at 55º C Total Current Required For 320m² x 0.41mA = 0.131A Considering Coating Deficiency as 5% Final Current Requirement: = 16mA OR 0.016A Ground Bed Resistance using Dwight's Formula for a single vertical anode = 5.1128Ω Based on Soli Resistivity = 1000Ω-cm and choosing 15lbs Zinc anode, size 1.4"x1.4"x30" package size 5"x38", 50lbs weight. Driving Potential of the anode = 1.1-0.95 = 0.15 volts (assuming SRBs presence) Design Life = 25 Years (15lbs Zinc anode consumption rate 0.27kg/Year)

description

CALCULATIONS

Transcript of Design Calculations

Page 1: Design Calculations

Design Calculations

Length of line:- 2 Km

Diameter: - 2 Inch

Total Surface Area: D x π x L = 0.0512 x 3.14 x 2000 = 318.78 M²

Say Total surface area to be protected 320 M²

Current Density Chosen= 0.25mA/m² at 30º C OR 0.41mA/ m² at 55º C

Total Current Required For 320m² x 0.41mA = 0.131A

Considering Coating Deficiency as 5%

Final Current Requirement: = 16mA OR 0.016A

Ground Bed Resistance using Dwight's Formula for a single vertical anode = 5.1128Ω

Based on Soli Resistivity = 1000Ω-cm and choosing 15lbs Zinc anode, size 1.4"x1.4"x30" package size 5"x38", 50lbs weight.

Driving Potential of the anode = 1.1-0.95 = 0.15 volts (assuming SRBs presence)

Design Life = 25 Years (15lbs Zinc anode consumption rate 0.27kg/Year)