Description of various components/sub-assemblies.

32
Description of various components/sub- assemblies

Transcript of Description of various components/sub-assemblies.

Page 1: Description of various components/sub-assemblies.

Description of various components/sub-assemblies

Page 2: Description of various components/sub-assemblies.

DESCRIPTION OF VARIOUS MODULES

NAME DESCRIPTIONSUPPLY

VOLTAGE

A-1 AC Compact Controller 110 VDC

A-2 Disconnecting & Earthing Device750 VAC, 110 VDC

A-3 Regulated Charger (RBC)415 VAC/110 VDC

A-5 Pump Controller110 VDC, 24 VDC

A-6 Insulation Control Relay AC 110V220 VAC, 110 VAC

A-7Insulation Control Relay AC 240V/415V

220 VAC

A-8DC/ DC Converter (110V/24V) for Return/ Fresh Air Flap Servo Motors, Bar Gauges & Transducers

110 VDC/24 VDC

Page 3: Description of various components/sub-assemblies.

PROTECTION DEVICES

NAME DESCRIPTIONSUPPLY

VOLTAGE

F-01MCB (Triple Pole) 10A for Ventilation Fan Motor Unit 1 (Blower Motor-1)

415 VAC

F-02MCB (Triple Pole) 10A for Ventilation Fan Motor Unit 2 (Blower Motor-2)

415 VAC

F-03MCB (Triple Pole) 20A for Compressor Motor 1.1

415 VAC

F-04MCB (Double Pole) 10A for Crankcase Heaters (for CP 1.1 & CP 1.2)

220 VAC

F-05MCB (Triple Pole) 20A for Compressor Motor 1.2

415 VAC

F-06MCB (Triple Pole) 10A for Condenser Fan Motor 1.1

415 VAC

F-07MCB (Triple Pole) 10A for Condenser Fan Motor 1.2

415 VAC

F-08 MCB (Triple Pole) 6A for Heater Unit-1 415 VAC

Page 4: Description of various components/sub-assemblies.

PROTECTION DEVICES

NAME DESCRIPTIONSUPPLY

VOLTAGE

F-09MCB (Triple Pole) 20A for Compressor Motor 2.1

415 VAC

F-10MCB (Double Pole) 10A for Crankcase Heaters (for CP 2.1 & CP 2.2)

220 VAC

F-11MCB (Triple Pole) 20A for Compressor Motor 2.2

415 VAC

F-12MCB (Triple Pole) 10A for Condenser Fan Motor 2.1

415 VAC

F-13MCB (Triple Pole) 10A for Condenser Fan Motor 2.2

415 VAC

F-14MCB (Triple Pole) 16A for Heater Unit-2 (PPS)

415 VAC

F-15 MCB (Triple Pole) 16A for Exhaust Fans 415 VAC

F-16 MCB (Double Pole) 16A for Water Boiler 220 VAC

Page 5: Description of various components/sub-assemblies.

PROTECTION DEVICES

NAME DESCRIPTIONSUPPLY

VOLTAGE

F-17 MCB (Double Pole) 10A for Soup Boiler 220 VAC

F-18 MCB (Double Pole) 16A for Hot Case 220 VAC

F-19 MCB (Double Pole) 6A for Bottle Cooler 220 VAC

F-20MCB (Double Pole) 6A for Refrigerator (Deep Freezer)

220 VAC

A-21MPCB (Motor Protection Circuit Breaker) (1 to 1.6A) for Water Pump-1

415 VAC

A-22MPCB (Motor Protection Circuit Breaker) (1 to 1.6A) for Water Pump-2 (Overload Relay for Water Pump-2)

415 VAC

F-24 MCB (Double Pole) 10A for Light Control 110 VDC

F-17 MCB (Double Pole) 10A for Soup Boiler 220 VAC

Page 6: Description of various components/sub-assemblies.

PROTECTION DEVICES

NAME DESCRIPTIONSUPPLY

VOLTAGE

F-25MCB (Double Pole) 10A for Emergency Lights

110 VDC

F-26MCB (Double Pole) 10A for Emergency Lights

110 VDC

F-27MCB (Double Pole) 16A for Reading Lights

110 VDC

F-28MCB (Double Pole) 16A for Reading Lights

110 VDC

F-29MCB (Double Pole) 16A for DC/DC Converter

110 VDC

F-30MCB (Double Pole) 6A for Minimal Voltage Relay

110 VDC

F-31MCB (Double Pole) 6A for Telephone (First Class only)

110 VDC

F-32MCB (Double Pole) 6A for Diagnosis (Indications & ACP lights)

110 VDC

Page 7: Description of various components/sub-assemblies.

PROTECTION DEVICES

NAME DESCRIPTIONSUPPLY

VOLTAGE

F-33MCB (Double Pole) 10A for Power Supply

110 VDC

F-34 MCB (Double Pole) 10A for Night Lights 110 VDC

F-35MCB (Double Pole) 6A for AC Compact Controller

110 VDC

F-36 MCB (Double Pole) 6A for Pump Control24 VDC, 110

VDC

F-37MCB (Double Pole) 10A for Sanitary Control

24 VDC

F-38MCB (Double Pole) 10A for Loud Speaker

24 VDC

F-39 MCB (Double Pole) 10A for Coach Light 110 VAC

F-40 MCB (Double Pole) 10A for Coach Light 110 VAC

Page 8: Description of various components/sub-assemblies.

PROTECTION DEVICES

NAME DESCRIPTIONSUPPLY

VOLTAGE

F-41MCB (Double Pole) 6A for Electric Razor Socket

110 VAC

F-42HRC Fuse (25A) for 110V (+ve) DC Supply to Panel

110 VAC

F-43HRC Fuse (25A) for 110V (-ve) DC Supply to Panel

110 VAC

F-44HRC Fuse (100A) in R-phase of Output of 60 KVA Transformer

415 VAC

F-45HRC Fuse (100A) in Y-phase of Output of 60 KVA Transformer

415 VAC

F-46HRC Fuse (100A) in B-phase of Output of 60 KVA Transformer

415 VAC

F-47HRC Fuse (80A) in Local Main Supply (R-phase)

415 VAC

F-48HRC Fuse (80A) in Local Main Supply (Y-phase)

415 VAC

Page 9: Description of various components/sub-assemblies.

PROTECTION DEVICESNAME DESCRIPTION SUPPLY VOLTAGE

F-49HRC Fuse (80A) in Local Main Supply (B-phase)

415 VAC

F-50HRC Fuse HT (63A) in R-phase for Network-1(Feeder-1)

750 VAC

F-51HRC Fuse HT (63A) in Y-phase for Network-1(Feeder-1)

750 VAC

F-52HRC Fuse HT (63A) in B-phase for Network-1(Feeder-1)

750 VAC

F-53HRC Fuse HT (63A) in R-phase for Network-2(Feeder-2)

750 VAC

F-54HRC Fuse HT (63A) in Y-phase for Network-2(Feeder-2)

750 VAC

F-49HRC Fuse (80A) in Local Main Supply (B-phase)

415 VAC

F-50HRC Fuse HT (63A) in R-phase for Network-1(Feeder-1)

750 VAC

Page 10: Description of various components/sub-assemblies.

PROTECTION DEVICES

NAME DESCRIPTIONSUPPLY

VOLTAGE

F-49HRC Fuse (80A) in Local Main Supply (B-phase)

415 VAC

F-50HRC Fuse HT (63A) in R-phase for Network-1(Feeder-1)

750 VAC

F-51HRC Fuse HT (63A) in Y-phase for Network-1(Feeder-1)

750 VAC

F-52HRC Fuse HT (63A) in B-phase for Network-1(Feeder-1)

750 VAC

F-53HRC Fuse HT (63A) in R-phase for Network-2(Feeder-2)

750 VAC

F-54HRC Fuse HT (63A) in Y-phase for Network-2(Feeder-2)

750 VAC

F-55HRC Fuse HT (63A) in B-phase for Network-2(Feeder-2)

750 VAC

F-56Glass Fuse (4A) UIC Remote Control (+ve)

24 VDC

Page 11: Description of various components/sub-assemblies.

PROTECTION DEVICESName Description Supply voltage

F-57 Glass Fuse (2A) UIC Remote Control (-ve) 24 VDC

F-58 Glass Fuse (2A) in Phase for AC 110V Insulation Control Relay (A-6) 110 VAC

F-59 Glass Fuse (2A) in Neutral for AC 110V Insulation Control Relay (A-6) 110 VAC

F-60Glass Fuse (4A) in for AC 110V Insulation Control Relay (A-6) & AC 240V /415V Insulation Control Relay (A-7)

220 VAC

F-61Control Relay (A-6) & AC 240V/415V Insulation Control Relay (A-7) Glass Fuse (2A) in Neutral for AC 110V Insulation

220 VAC

F-62 Control Relay (A-6) & AC 240V/415V Insulation Control Relay (A-7) 220 VAC

F-63 Glass Fuse (6.3A) in +ve 110V DC for Anti Skid Device 110 VDC

F-64 Glass Fuse (6.3A) in +ve 110V DC for Brake 110 VDC

Page 12: Description of various components/sub-assemblies.

PROTECTION DEVICESNAME DESCRIPTION

SUPPLY VOLTAGE

F-65Glass Fuse (6.3A) in -ve 110V DC for Anti Skid Device

110 VDC

F-66Glass Fuse (6.3A) in -ve 110V DC for Brake

110 VDC

F-67 Glass Fuse (1A) in Control Supply of K-41 220 VAC

F-68 Glass Fuse (1A) in Control Supply of K-42 220 VAC

F-69Glass Fuse (1A) in R-phase of K-45 (MMR for LMS)

415 VAC

F-70Glass Fuse (1A) in Y-phase of K-45 (MMR for LMS)

415 VAC

F-71Glass Fuse (1A) in B-phase of K-45 (MMR for LMS)

415 VAC

F-72 Glass Fuse (1A) in Control Supply of K-44 220 VAC

Page 13: Description of various components/sub-assemblies.

PROTECTION DEVICESF-73 Glass Fuse (1A) in Control Supply of K-23 220 VAC

F-74Glass Fuse (10A) in Input Phase of Lighting X’mer

220 VAC

F-75Glass Fuse (10A) in Input Neutral of Lighting X’mer

220 VAC

F-76HRC Fuse (100A) in R-phase of Output of 60 KVA Transformer No. 2 (in Pantry car & German Power car)

415 VAC

F-77HRC Fuse (100A) in Y-phase of Output of 60 KVA Transformer No. 2 (in Pantry car & German Power car)

415 VAC

F-78HRC Fuse (100A) in B-phase of Output of 60 KVA Transformer No. 2 (in Pantry car & German Power car)

415 VAC

F-79HRC Fuse (63A) in R-phase for Radiator Motor, Roof Extractor-1 & 2

415 VAC

F-80HRC Fuse (63A) in Y-phase for Radiator Motor, Roof Extractor-1 & 2

415 VAC

Page 14: Description of various components/sub-assemblies.

PROTECTION DEVICESNAME DESCRIPTION

SUPPLY VOLTAGE

F-81HRC Fuse (63A) in B-phase for Radiator Motor, Roof Extractor-1 & 2

415 VAC

F-82HRC Fuse (63A) in R-phase for Radiator Motor, Roof Extractor-3 & 4

415 VAC

F-83HRC Fuse (63A) in Y-phase for Radiator Motor, Roof Extractor-3 & 4

415 VAC

F-84HRC Fuse (63A) in B-phase for Radiator Motor, Roof Extractor-3 & 4

415 VAC

F-85Motor Protection Circuit Breaker (MPCB) (0.1 to 2.5A) for Exhaust Fan-I

415 VAC

F-86Motor Protection Circuit Breaker (MPCB) (0.1 to 2.5A) for Exhaust Fan-II

415 VAC

F-87Motor Protection Circuit Breaker (MPCB) (0.25 to 4.0A) for Exhaust Fan-III

415 VAC

F-90HRC Fuse (1A) in R-phase of 750V Volt Meter Network-1 (Feeder-1)

750 VAC

Page 15: Description of various components/sub-assemblies.

PROTECTION DEVICESNAME DESCRIPTION

SUPPLY VOLTAGE

F-91HRC Fuse (1A) in Y-phase of 750V Volt Meter Network-1 (Feeder-1)

750 VAC

F-93HRC Fuse (1A) in B-phase of 750V Volt Meter Network-1 (Feeder-1)

750 VAC

F-94HRC Fuse (1A) in R-phase of 750V Volt Meter Network-2 (Feeder-2)

750 VAC

F-95HRC Fuse (1A) in Y-phase of 750V Volt Meter Network-2 (Feeder-2)

750 VAC

F-96HRC Fuse (1A) in B-phase of 750V Volt Meter Network-2 (Feeder-2)

750 VAC

F-97HRC Fuse (1A) in Control Supply of K-01 Net-1 Contactor (in Rev.-D only)

750 VAC

F-98HRC Fuse (1A) in Control Supply of K-01 Net-2 Contactor (in Rev.-D only)

750 VAC

F-91HRC Fuse (1A) in Y-phase of 750V Volt Meter Network-1 (Feeder-1)

750 VAC

Page 16: Description of various components/sub-assemblies.

PROTECTION DEVICES

NAME DESCRIPTIONSUPPLY

VOLTAGE

F-100Glass Fuse (2A) in Phase of Insulation Control Relay AC 415/240V for Transformer-1 (in Power Cars only)

220 VAC

F-101Glass Fuse (2A) in Phase of Insulation Control Relay AC 415/240V for Transformer-1 (in Power Cars only)

220 VAC

F-102Glass Fuse (2A) in Phase of Insulation Control Relay AC 415/240V for Transformer-2 (in Power Cars only)

220 VAC

F-103Glass Fuse (2A) in Phase of Insulation Control Relay AC 415/240V for Transformer-2 (in Power Cars only)

220 VAC

Page 17: Description of various components/sub-assemblies.

INDICATIONS

NAME DESCRIPTIONSUPPLY

VOLTAGE

H-1 Indication Operation Supply Network-1 110 VDC

H-2 Indication Operation Supply Network-2 110 VDC

H-3 Indication Operation Charger Float 110 VDC

H-4 Indication Operation Local Main Supply-1 110 VDC

H-5 Indication Operation Local Main Supply-2 110 VDC

H-6 Indication Operation Charger Boost 110 VDC

H-7 Indication Anti Skid Device Defect 110 VDC

H-8 Indication Insulation Failure 110V 110 VDC

H-9 Indication Insulation Failure 415V 110 VDC

H-10 Indication Operation 415V OK 110 VDC

Page 18: Description of various components/sub-assemblies.

CONTACTORS & RELAYSNAME DESCRIPTION

SUPPLY VOLTAGE

K-01 Main Feeder Contactor Network-1 (Feeder-1) 110 VDC, 750 VAC

K-02 Main Feeder Contactor Network-2 (Feeder-2) 110 VDC, 750 VAC

K-03Measuring & Monitoring Relay (MMR) for Network-1(Feeder-1) 750 VAC

24 VDC, 110 VDC,

K-04Measuring & Monitoring Relay (MMR) for Network-2(Feeder-2) 750 VAC

24 VDC, 110 VDC,

K-05 Timer for Anti Skid Device 110 VDCK-06 Contactor for Electro Pneumatic Brake Application 24 VDC, 110 VDC

K-07 Contactor for Electro Pneumatic Brake Release 24 VDC, 110 VDC

K-08Contactor for Level 1 of Minimal Voltage Relay (MVR) (96V+120 Minutes for Emergency Light OFF)

110 VDC

K-09Contactor for Level 2 of Minimal Voltage Relay(MVR) (104V+30 Minutes for DC/DC Converters OFF)

110 VDC

K-10Contactor for Level 3 of Minimal Voltage Relay (MVR) (106V for Reading Light OFF)

110 VDC, 220 VAC

Page 19: Description of various components/sub-assemblies.

CONTACTORS & RELAYS

NAME DESCRIPTIONSUPPLY

VOLTAGE

K-11 Contactor for Main Light Passenger Room 110 VDC, 110 VAC

K-12 Contactor for Reading Light 110 VDC

K-13 Contactor for Night Light 110 VDC

K-14Contactor for Main Light Entrance Area & Sanitory Rooms

110 VDC, 110 VAC

K-15 Contactor for Emergency Light 110 VDC

K-16 Contactor for Emergency Light 110 VDC

K-17 Timer for Light ON/OFF (15-300 Min) 110 VDC

K-18Timer for External Power Supply/ Local Main Supply (L.M.S.) (for blinking of outdoor lamps)

110 VDC

K-19 Relay for UIC-Light-Remote Control ON 24 VDC, 110 VDC

K-20 Relay for UIC-Light-Remote Control OFF 24 VDC, 110 VDC

Page 20: Description of various components/sub-assemblies.

CONTACTORS & RELAYSNAME DESCRIPTION

SUPPLY VOLTAGE

K-21 Contactor for Fresh Air Flap Motor 24 VDC

K-22 Contactor for Return Air Flap Motor 24 VDC

K-23 Contactor for 415V OK 110 VDC, 220 VAC

K-24 Contactor for Water Pump No. 124 VDC/110 VDC,

415 VAC

K-25 Contactor for Water Pump No. 224 VDC/110 VDC,

415 VAC

K-26Contactor for Ventilation Fan Motor Unit-1(Blower-1/NPPS)

110 VDC, 415 VAC

K-27 Contactor for Controller OK 110 VDC

K-28Contactor for Ventilation Fan Motor Unit-2 (Blower-2/PPS)

110 VDC, 415 VAC

K-29 Contactor for Exhaust Fan Motors 110 VDC, 415 VAC

K-31 Contactor for Condenser Fan Motor 1.1 110 VDC, 415 VAC

Page 21: Description of various components/sub-assemblies.

CONTACTORS & RELAYSNAME DESCRIPTION

SUPPLY VOLTAGE

K-32 Contactor for Condenser Fan Motor 1.2 110 VDC, 415 VAC

K-33 Contactor for Compressor Motor 1.1 110 VDC, 415 VAC

K-34 Contactor for Compressor Motor 1.2 110 VDC, 415 VAC

K-35 Contactor for Heater Unit 1 (NPPS) 110 VDC, 415 VAC

K-36 Contactor for Condenser Fan Motor 2.1 110 VDC, 415 VAC

K-37 Contactor for Condenser Fan Motor 2.2 110 VDC, 415 VAC

K-38 Contactor for Compressor Motor 2.1 110 VDC, 415 VAC

K-39 Contactor for Compressor Motor 2.2 110 VDC, 415 VAC

K-40 Contactor for Heater Unit 2 (PPS) 110 VDC, 415 VAC

K-41 Contactor for Local Main Supply-1 (LMS-1) 220 VAC, 415 VAC

Page 22: Description of various components/sub-assemblies.

CONTACTORS & RELAYSNAME DESCRIPTION

SUPPLY VOLTAGE

K-42 Contactor for Local Main Supply-2 (LMS-2) 220 VAC, 415 VAC

K-43 Main Contactor for Local Main Supply (LMS) 110 VDC, 415 VAC

K-44Contactor in the Output of 60 KVA Transformer

(After 100A Fuses)220 VAC, 415 VAC

K-45Measuring & Monitoring Relay (MMR) for Local

Main Supply (LMS)110 VDC, 415 VAC

K-46Contactor in the Output of 60 KVA Transformer-2

(in Original German Power cars & Pantry cars)220 VAC, 415 VAC

K-48Interlocking Contactor for Changeover of Coach Light Supply from 110V AC to 110V DC & vice

versa110 VAC, 110 VDC

K-RBC

Contactor for Regulated Battery Charger (Main Charger)

415 VAC

Page 23: Description of various components/sub-assemblies.

METERSNAME DESCRIPTION

SUPPLY VOLTAGE

P-1 Ampere Meter, AC (0-200 Amp) for Panel Load mV

P-2 Volt Meter, AC (0-800V) for Network-1 (RY) 750 VAC

P-3 Volt Meter, AC (0-800V) for Network-1 (YB) 750 VAC

P-4 Volt Meter, AC (0-800V) for Network-1 (BR) 750 VAC

P-5 Volt Meter, AC (0-800V) for Network-2 (RY) 750 VAC

P-6 Volt Meter, AC (0-800V) for Network-2 (YB) 750 VAC

P-7 Volt Meter, AC (0-800V) for Network-2 (BR) 750 VAC

P-8Ampere Meter, DC (+ve 100-0-100 -ve) for Charge-Discharge Battery Net

mV

P-9Ampere Meter, DC (0-40Amp) for Consumer Current Net

mV

P-10 Volt Meter, DC (0-150V) for Battery Net 110 VDC

Page 24: Description of various components/sub-assemblies.

SWITCHESNAME DESCRIPTION SUPPLY

VOLTAGE

S-01Switch, Selector Power Supply ON/OFF (Rev.-D)

110 VAC, 110 VDC/

415 VAC, 750 VAC

S-02Switch, Selector Net-1, Net-2 & LMS(Rev.-D)

110 VDC/415 VAC, 750 VAC

S-03 Switch, Push Button for Insulation Test Battery Net +ve 110 VDC

S-04 Switch, Push Button for Insulation Test Battery Net –ve 110 VDC

S-05 Switch, Push Button for Test Indication Lamps 110 VDC

S-06 Switch, Push Button for Train Light ON 24 VDC

S-07 Switch, Push Button for Train Light OFF 24 VDC

S-08 Switch, Push Button for Lighting ON 24 VDC

S-09 Switch, Push Button for Night Lighting ON 110 VDC

S-10 Switch, Push Button for Lighting OFF 110 VDC

Page 25: Description of various components/sub-assemblies.

CONVERTERSNAME DESCRIPTION

SUPPLY VOLTAGE

U-1 Anti Skid Device 110 VDC

U-2.1DC/DC Converter (110V/24V) for Water Pump Control & Sanitory Control

110 VDC, 24 VDC

U-2.2DC/DC Converter (110V/24V) for Loud Speaker System MMRs & UIC Remote Control

110 VDC, 24 VDC

U-2.3 Minimal Voltage Relay (MVR) 110 VDC

U-3 Amplifier Loud Speaker system 24 VDC

U-4 Air Conditioning Control Switch Panel 24 VDC, 110 VDC

Page 26: Description of various components/sub-assemblies.

THREE PHASE POWER TERMINAL FOR AC PLANT

Terminal no. Description Terminal no. Description

231

Ventilation-1

256

CD fan 1.2232 257

233 258

234 Earth 259

Compressor 2.1235

Ventilation-2

260

236 261

237 262 Earth

238 Earth 263

Compressor 2.2239

Compressor 1.1

264

240 265

241 266 Earth

242 Earth 267

Heater-2243Compressor 1.2

268

244 269

Page 27: Description of various components/sub-assemblies.

THREE PHASE POWER TERMINAL FOR AC PLANT

Fuse No. Rating (A) Description (Located in)

75 10 Neutral Input supply to Lighting transformer

74 10 Phase Input supply to Lighting transformer

73 1 Control supply to K-23

72 1 Control supply to K-44

71 1 Blue Phase of MMR of local Main Supply

70 1 Yellow Phase of MMR of local Main Supply

69 1 Red Phase of MMR of local Main Supply

68 1 Control supply to K-42

67 1 Control supply to K-41

66 6.3 -ve 110 VDC supply for Brake

65 6.3 -ve 110 VDC supply for Anti Skid device

64 6.3 +ve 110 VDC supply for Brake

63 6.3 +ve 110 VDC supply for Anti Skid device

62 2Neutral of AC 110 V Insulation Control relay (A-6) & AC 240/415 V Insulation Control relay (A-7)

Page 28: Description of various components/sub-assemblies.

THREE PHASE POWER TERMINAL FOR AC PLANT

Fuse No. Rating (A) Description (Located in)

61 4

60 4Phase of AC 110 V Insulation Control relay (A-6) & AC 240/415 V Insulation Control relay (A-7)

59 2 Neutral of AC 110 V Insulation Control relay (A-6)

58 2 Phase of AC 110 V Insulation Control relay (A-6)

57 2 -ve of 24 V UIC remote control

56 4 +ve of 24 V UIC remote control

Page 29: Description of various components/sub-assemblies.

X 301 X 5011 O C D

IGIT

AL

OU

TP

UT

O 1 Controller OK Fault O 11

O 15

O C 6

2 O 1 O 11 5

3 O 2O 2 Recirculation

AirOut Side

Air O 12O 12 4

4 O 3 3

5 O 4O 3 Ventilation

Fan 1Ventilation

Fan 2 O 13O 14 2

6 O 5 1

X 302O 4 Not Active in

SystemExhaust

Fan O 14X 502

1 O C DIG

ITA

L O

UT

PU

T

O 19

O C 6

2 O 6O 5 Bypass

Cooling 1/1Bypass

Cooling 2/1 O 15O 16 5

3 O 7 4

4 O 8O 6 Condenser

Fan 1/1Condenser

Fan 2/1 O 16O 18 3

5 O 9 2

6 O 10O 7 Condenser

Fan 1/2Condenser

Fan 2/2 O 17O 20 1

X 701 X 702

LED layout on microprocessor controller

Page 30: Description of various components/sub-assemblies.

1 RES

NE

TW

OR

K

I 3Temp. Cond. Motor 1.2 OK

Temp. Cond.

Motor 2.2 OK

I 13

-  

2 CH

+  

3 CL

I 4Vent Motor 1 Fault

Vent Motor 2

FaultI 14

-  

4 0V X 403 X 402

X 102I 5

Temp. E.I. Heater 1 OK

Temp. E.I. Heater 2

OKI 15

 

  10

1 RES NE

TW

OR

K

  9

2 CHI 6

Low Pressure 1.1 OK

Low Pressure 2.1 OK

I 16  8

3 CL 7

4 0VI 7

Low Pressure 1.2 OK

Low Pressure 2.2 OK

I 17  6

X 103 5

RS 232 CI 8

Control Pressure 1

Control Pressure 2

I 18  4

X 104 3

1 +

AN

A L

OG

OU

T

I 9High Pressure 1.1 Fault

High Pressure 2.1 Fault

I 19  2

1

2 -

OUT

High Pressure 1.2

Fault

High Pressure 2.2 Fault

I 20

X 104

GND 2

1

Page 31: Description of various components/sub-assemblies.

1 I 1O 8 Compressor

1/1Compresso

r 2/1 O 18I 11

2 I 2 I 12

3 I 3O 9 Compressor

1/2Compresso

r 2/2 O 19I 13

4 I 4

DIG

ITA

L IN

PU

T

I C

I 14

5 I 5 O 10 E.I. Heater 1 E.I. Heater

2 O 20I 15

6 I C

7 I 6RUN :

STAT 1 I 16

8 I 7 STAT 2 I 17

9 I 8 I 18

10 I 9I 1 Air - Co.

'ON' 400V OK I 11I 19

11 I 10 I 20

12 I C

I 2Temp. Cond.

Motor 1.1 OK

Temp. Cond.

Motor 2.1 OK

I 12

X 104

X 101

ANALOG INP

4….20 MA

+

Page 32: Description of various components/sub-assemblies.

1 RES

NE

TW

OR

K

I 3Temp. Cond. Motor 1.2 OK

Temp. Cond.

Motor 2.2 OK

I 13

-  

2 CH

+  

3 CL

I 4 Vent Motor 1 Fault

Vent Motor 2

FaultI 14

-  

4 0V X 403 X 402

X 102I 5 Temp. E.I.

Heater 1 OK

Temp. E.I. Heater 2

OKI 15

 

  10

1 RES NE

TW

OR

K

  9

2 CHI 6

Low Pressure 1.1 OK

Low Pressure 2.1 OK

I 16  8

3 CL 7

4 0VI 7

Low Pressure 1.2 OK

Low Pressure 2.2 OK

I 17  6

X 103 5

RS 232 CI 8 Control

Pressure 1Control

Pressure 2 I 18  4

X 104 3

1 +

AN

A L

OG

OU

T

I 9High Pressure 1.1 Fault

High Pressure 2.1 Fault

I 19  2

1

2 -

OUT

High Pressure 1.2

Fault

High Pressure 2.2 Fault

I 20

X 104

GND 2

1