DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY :...

24
VA 100 Primary (Volts) 120 Secondary (Volts) 12 Input /Output Amps 0.83 / 8.33 Approvals 7HPSHUDWXUH 5LVH & ,QVXODWLRQ &ODVV % & Frequency 60Hz Polarity additive Noise level less than 40DB DESCRIPTION Type Enclosed,Indoor application Winding Copper UL listed CSA approved MODEL MC100A 0.25 x 0.500 MOUNTING INCHES / MM WEIGHT SHIP SLOTS B D C E 3.75 1.7 6.4 x 12.7 3.13 2.82 136.7 2.50 2.25 79.5 63.5 57.2 DIMENSIONS 5.38 71.6 A LBS / KG INCHES / MM VA 100 WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : H1-H2 120 CONNECT LINES TO : VOLTS X1-X2 12 CONNECTION DIAGRAM H2 H1 X1 0V 0V X2 120 V 12 V G I H J F L K M 4.00(S) 2.50(T) 101.6 63.5 LETTER S 0.25 x 0.625 6.4 x 15.9 T a b a b H D E I TECHNICAL DATA MARCUS SINGLE PHASE CONTROL TRANSFORMER Marcus Transformer LTD Phone: 1-800-267-7376 Fax: 1-866-205-7526 Email: [email protected]

Transcript of DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY :...

Page 1: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 120

Secondary (Volts) 12

Input /Output Amps 0.83 / 8.33

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Enclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100A

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2120

CONNECT LINES TO :

VOLTS

X1-X212

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

120 V

12 V

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 2: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 120

Secondary (Volts) 24

Input /Output Amps 0.83 / 4.17

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Enclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100B

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2120

CONNECT LINES TO :

VOLTS

X1-X224

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

120 V

24 V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 3: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 120

Secondary (Volts) 120

Input /Output Amps 0.83 / 0.83

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

TypeEnclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100C

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2120

CONNECT LINES TO :

VOLTS

X1-X2120

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

120 V

120 V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 4: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 208

Secondary (Volts) 24

Input /Output Amps 0.48 / 4.17

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Enclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100D

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2208

CONNECT LINES TO :

VOLTS

X1-X224

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

208 V

24 V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 5: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 208

Secondary (Volts) 120

Input /Output Amps 0.48 / 0.83

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Enclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100E

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2208

CONNECT LINES TO :

VOLTS

X1-X2

120

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

208 V

120 V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 6: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 120 / 240

Secondary (Volts) 12 / 24

Input /Output Amps 0.83 , 0.42 / 8.33 , 4.17

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Enclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100F

CONNECTION DIAGRAM

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H4

120

240

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

12

24

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

H4 H1

X1 X3

X2 X4

H2H3

0V

0V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH J

F

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 7: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 120 / 240

Secondary (Volts) 16 / 32

Input /Output Amps 0.83 , 0.42 / 6.25 , 3.13

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Enclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100G

CONNECTION DIAGRAM

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H4

120

240

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

16

32

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

H4 H1

X1 X3

X2 X4

H2H3

0V

0V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 8: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 240

Secondary (Volts) 24

Input /Output Amps 0.42 / 4.17

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Enclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100H

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2240

CONNECT LINES TO :

VOLTS

X1-X2

24

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

240 V

24 V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 9: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 240

Secondary (Volts) 120

Input /Output Amps 0.42 / 0.83

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Enclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100I

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2240

CONNECT LINES TO :

VOLTS

X1-X2

120

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

240 V

120 V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 10: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 277

Secondary (Volts) 120 / 240

Input /Output Amps 0.36 / 0.83 , 0.42

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Closed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100J

CONNECTION DIAGRAM

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2277

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

X1-X4

120/240 X2-X3 X1-X3-X4

H2

H1

X1 X2

0V

0V

X4X3

277 V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 11: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 347

Secondary (Volts) 120 / 240

Input /Output Amps 0.29 / 0.83 , 0.42

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Enclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100K

CONNECTION DIAGRAM

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2347

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

X1-X4

120/240X2-X3 X1-X3-X4

H2

H1

X1 X2

0V

0V

X4X3

347 V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 12: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 380

Secondary (Volts) 120 / 240

Input /Output Amps 0.29 / 0.83 , 0.42

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Enclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100L

CONNECTION DIAGRAM

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2380

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

X1-X4

120/240 X2-X3 X1-X3-X4

H2

H1

X1 X2

0V

0V

X4X3

380 V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH J

F

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 13: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 208 / 416

Secondary (Volts) 12 / 24

Input /Output Amps 0.48 , 0.24 / 8.33 , 4.17

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Enclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100M

CONNECTION DIAGRAM

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H4

208

416

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

12

24

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

H4 H1

X1 X3

X2 X4

H2H3

0V

0V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 14: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 208 / 416

Secondary (Volts) 120 / 240

Input /Output Amps 0.48 , 0.24 / 0.83 , 0.42

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

TypeEnclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100N

CONNECTION DIAGRAM

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H4

208

416

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

H4 H1

X1 X3

X2 X4

H2

H3

0V

0V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 15: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 240 / 480

Secondary (Volts) 120 / 240

Input /Output Amps 0.42 , 0.21 / 0.83 , 0.42

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Enclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100O

CONNECTION DIAGRAM

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H4

240

480

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

H4 H1

X1 X3

X2 X4

H2

H3

0V

0V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 16: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 480

Secondary (Volts) 24

Input /Output Amps 0.21 / 4.17

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

TypeEnclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100P

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2480

CONNECT LINES TO :

VOLTS

X1-X2

24

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

480 V

24 V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 17: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 480

Secondary (Volts) 120

Input /Output Amps 0.21 / 0.83

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

TypeEnclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100Q

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2480

CONNECT LINES TO :

VOLTS

X1-X2

120

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

480 V

120 V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 18: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 600

Secondary (Volts) 12 / 24

Input /Output Amps 0.17 / 8.33 , 4.17

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Enclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100R

CONNECTION DIAGRAM

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2600

VOLTS

12

24

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

X1-X4

12/24X2-X3 X1-X3-X4

H2

H1

X1 X2

0V

0V

X4X3

600 V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 19: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 600

Secondary (Volts) 24

Input /Output Amps 0.17 / 4.17

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Enclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100S

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2600

CONNECT LINES TO :

VOLTS

X1-X2

24

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

600 V

24 V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 20: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 600

Secondary (Volts) 120

Input /Output Amps 0.17 / 0.83

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Enclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100T

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2600

CONNECT LINES TO :

VOLTS

X1-X2

120

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

600 V

120 V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 21: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 600

Secondary (Volts) 240

Input /Output Amps 0.17 / 0.42

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

TypeEnclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100U

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2600

CONNECT LINES TO :

VOLTS

X1-X2

240

CONNECTION DIAGRAM

H2H1

X1

0V

0V

X2

600 V

240 V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 22: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 600

Secondary (Volts) 120 / 240

Input /Output Amps 0.17 / 0.83 , 0.42

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

TypeEnclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100V

CONNECTION DIAGRAM

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2600

VOLTS

120

240

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

X1-X4

120/240 X2-X3 X1-X3-X4

H2

H1

X1 X2

0V

0V

X4X3

600 V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 23: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 240 / 480

Secondary (Volts) 12 / 24

Input /Output Amps 0.42 , 0.21 / 8.33 , 4.17

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Enclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100X

CONNECTION DIAGRAM

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H4

240

480

INTERCONNECT:

H1-H3 AND H2-H4

H2-H3

VOLTS

12

24

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H4

X1-X4

H4 H1

X1 X3

X2 X4

H2H3

0V

0V

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH JF

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]

Page 24: DESCRIPTION CONNECTION DIAGRAM - Marcus … DIAGRAM WIRING CONNECTION CONNECT LINES TO : PRIMARY : VOLTS SECONDARY : 347 H1-H2 VOLTS 120 240 INTERCONNECT: X1-X3 AND X2-X4 X2-X3 INCHES

VA 100

Primary (Volts) 347 / 380

Secondary (Volts) 12 / 24

Input /Output Amps 0.29 , 0.26 / 8.33 , 4.17

Approvals

Temperature Rise 95°C

Insulation Class B (130°C)

Frequency 50 / 60Hz

Polarity additive

Noise level less than 40DB

DESCRIPTION

Type Enclosed,Indoor application

Winding Copper

UL listed

CSA approved

MODEL MC100Y

WIRING CONNECTION

CONNECT LINES TO :

PRIMARY :

VOLTS

SECONDARY :

H1-H2347

380

VOLTS

12

24

INTERCONNECT:

X1-X3 AND X2-X4

X2-X3

CONNECT LINES TO :

X1-X4

H1-H3

X1-X4

Pos.

Volts

CONNECTION DIAGRAM

0V

H2

H3H1

X1X2X3

0V

347 380

X4

0V

H2 H3H1

Primary Tabs

0.25 x 0.500

MOUNTING

INCHES / MM

WEIGHT

SHIP

SLOTS

B DC E

3.75

1.7

6.4 x 12.7

3.132.82

136.7

2.502.25

79.5 63.557.2

DIMENSIONS

5.38

71.6

A

LBS / KG

INCHES / MM

VA

100

G

IH J

F

LK M

4.00(S)2.50(T)

101.663.5

LETTER

S

0.25 x 0.625

6.4 x 15.9

T

a

b

a b

H

D

E

I

TECHNICAL DATA

MARCUS

SINGLE PHASE CONTROL TRANSFORMER

Marcus Transformer LTD

Phone: 1-800-267-7376

Fax: 1-866-205-7526

Email: [email protected]