Deron Heat Pump Catalogue

39
0 Your Best Choice for Heat Pumps! DERON HEAT PUMP CATALOGUE Guangzhou Deron Heat Source Facilities Co., Ltd. The only one heat pump supplier for 16 th Asian Games! PDF created with pdfFactory Pro trial version www.pdffactory.com

Transcript of Deron Heat Pump Catalogue

Page 1: Deron Heat Pump Catalogue

0

Your Best Choice for Heat Pumps!

DERON HEAT PUMP CATALOGUE

Guangzhou Deron Heat Source Facilities Co., Ltd.

The only one heat pump supplier for 16th Asian Games!

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 2: Deron Heat Pump Catalogue

1

View of DERON Factory With high level laboratory and research staff, our production plant is able to supply you the world quality

products.

Energy Saving Technology Changes the World DERON HEAT PUMP SYSTEM

How does a heat pump work? A heat pump is a device moving heat energy from one place with lower temperature to another with higher temperature. This is done by extracting the heat from the air/earth. This heat is then upgraded to a higher temperature, before being delivered to the central heating system and hot water cylinder. Heat pumps also have the ability to do the reverse and provide a cooling system at warmer times of the year. Heat pumps are very economical, capable of cutting your heating bill by up to 70%. For every unit of electricity used to drive a heat pump, you can expect to produce 3-5 units of heat energy. The ratio between the heat produced and the electricity used to produce it, is refered to as the coefficienct of performance(COP).

Working principle A heat pump works by driving a working fluid around a refrigeration circuit containing four elements; (1) evaporator, (2) compressor, (3) condenser , (4) expansion valve.

ENTERPRISE PROFLIE Guangzhou Deron Heat Source Facilities Co., Ltd is developed by Deron Heat Pump Technology(Guangzhou) R&D Center and Deron Group Limited Company. The Company is a specialist in manufacturing marketing of pioneering heat source facilities.

DERON has brought in the advance heat pump technology from Germany and carried on to research, develop and innovate. DERON has established a world-class laboratory。 It is one of the first companies which is qualified for ISO9001 quality system, the European Union CE mark and the China Compulsory Certificate (CCC) in heat pump industry.

Up to now, in the world, DERON heat pumps including air to water heat pumps, water to water heat pumps and swimming pool heat pumps have provided good central heating solutions for hotels, hospitals, restaurants, schools, government institutions and residences, helping them save up to 75% of the power used originally.

The company has utilized advanced facilities and equipments from all countries such as Italy, Japan and the United States, in order to set up four production lines: two high-precision sheet metal production lines and two test lines. Over 40 models of heat pump systems vary from 0.8kw to 250kw, four different series-household usages, central hot water systems, large scale constructions and air conditioning water heating system. Our heat pumps are sold to Germany, The United Kingdom, France, Spain, Austria, Czech Republic, Australia, Brazil, Chile, South Africa, as well as other countries in the world.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 3: Deron Heat Pump Catalogue

2

Table of contents Air-to-water, Water-to-water, Swimming pool heat pump, Scroll/Screw heat pump, Household unit

1 Air to Water Heat Pump................................................................................................................................................................P-3 1.1 Air to Water Heat Pump Monobloc 380V/3ph/50Hz..............................................................................................................P-3

1.2 Air to Water Heat Pump Split Type for Cold Area……………………………………………………………….…………………..P-7 2. Air to Water Heat Pump DR Series:( Central Heating / Cooling + Hot Water)……………………………………………………..P-8 3. Household Heat pump with Coaxial Coil and Grundfos Pump..............................................................................................P-12 4. DW SERIES Heat Pump: Low Ambient (-25℃)……………………………………………...…………………………………..….…P-14 5. Water to Water Heat Pump.........................................................................................................................................................P-18

5.1 Water to Water heat pump Stand Type(Domestic or Commercial) .....................................................................................P-18 5.2 Water to Water heat pump SH series: Central heating + Hot water (Domestic Type) ........................................................P-21

6. Household Heat Pump Water Heater........................................................................................................................................P-23

6.1 Heat Pump Water Heater Split Type....................................................................................................................................P-23 6.2 Heat Pump Water Heater Integrative Type [All In One].......................................................................................................P-25

7. Swimming Pool/ SPA Air Source Heat Pump (Titanium Heat Exchanger).............................................................................P-27

7.1 Domestic Swimming Pool Heat Pump…………...………………………...............................................................................P-27 7.2 Commercial Swimming Pool heat pump……………………………...................................................................................P-29 7.2 Spa Heat Pump………………………………………………..…….........................................................................................P-32

9. Deron Production Line & Laboratory........................................................................................................................................P-33 10. Certificates and Trade shows..................................................................................................................................................P-36

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 4: Deron Heat Pump Catalogue

3

1.1 Air to Water Heat Pump Monobloc

DE-27WC, 36W/C, 46W/C DE-27W/D, 36W/D, 46W/D,52W/D DE-75W/D, 92W/D DE-180W/D, 270W/D

● Operation range: -10℃~+45℃ ambient temperature. ● 220V/1ph/50(60)Hz,380V/3ph/50(60)Hz. ● Multiple protections to protect the compressor and the heat exchanger. ● With auxiliary heating control, circulation pump control. ● Optional modular controller is available. ● With timer function. ● Adjustable defrosting according to different weather conditions. ● With terminal for indoor thermostat, starting or standby the heat pump. ● Anti-corrosion case: durable coating; no-screw design with stainless steel bolts and nuts, no rust. ● Simple installation: can be placed on roof top, balcony, yard, or basement. ● Low noise. Long lifespan up to 15 years.

Deron Intelligent Remote Controller Indoor

Threaded coaxial coil, largely increasing efficiency!

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 5: Deron Heat Pump Catalogue

4

Air Source Heat Pump Monobloc 220V/380V Datasheet (50Hz/60Hz)

Model DE-27W/C DE-46W/C DE-27W/D DE-36W/D DE-46W/D DE-52W/D Power supply(V/ph/Hz) 220/1/50 380/3/50 220/1/50 380/3/50 380/3/50 380/3/50

kw 10.8 18.4 10.8 14.4 18.4 20.8 *Heating capacity BTU 24550 49130 24550 49130 62780 70970

*Rated power input(kw) 2.7 4.6 2.7 3.6 4.6 5.2 kw 8.3 14.2 8.3 11 14.2 16 **Heating

capacity BTU 28160 49130 28160 37830 48340 54650 **Rated power input(kw) 2.2 3.8 2.2 3 3.8 4.3 Water feed speed(L/H) 240 415 240 325 415 470

Refrigerant R417A/R407C/R410A Refrigerant weight(g) 1850 2300 1850 2100 2300 2500

Max.current(A) 19.5 13 7.5 10 13 15 Rared water temp.(℃) 55 55 55 55 55 55 Max.water temp(℃) 60 60 60 60 60 60

Level against electric shock I I I I I I Water-proof grade IPX4 IPX4 IPX4 IPX4 IPX4 IPX4

Net weight(kg) 100 155 110 145 155 165 Net size(mm) 680X545X1055 800X700X1000 700X690X860 800X700X1000 800X700X1000 800X700X1150

Required water flow rate(m3/h) 2.2 4 2.2 3 4 5 Required tank cubage 2-3 3-5 2-3 3-5 3-5 3-5

Water connection G1" G1" G1" G1" G1" G1" Operation temp.range(℃) -10-45 -10-45 -10-45 -10-45 -10-45 -10-45

Test condition *Heating: Ambient temp. (DB/WB):20℃ /15℃, Water temp. (Initial/Final):15℃/55℃.

**Heating: Ambient temp. (DB/WB):7℃/6℃, Water temp. (In/Out):30℃/35℃.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 6: Deron Heat Pump Catalogue

5

Model DE-75W/D DE-92W/D DE-105W/D DE-150W/D DE-180W/D Power supply(V/ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50

kw 30 36.8 42 62 72 *Heating capacity

BTU 102360 125560 143300 211540 245660 *Rated power input(kw) 7.5 9.2 10.5 15 18

kw 23.1 28.3 32.3 47.7 55.4 **Heating capacity

BTU 78820 96680 110340 162880 189160 **Rated power input(kw) 6.2 7.5 8.6 12.3 14.8 Water feed speed(L/H) 678 825 938 1330 1665

Refrigerant R417A/R407C/R410A Refrigerant weight(g) 2100*2 2300X2 2500*2 2300*3 2300*4

Max.current(A) 21 25 28.5 40.5 49 Rared water temp.(℃) 55 55 55 55 55 Max.water temp(℃) 60 60 60 60 60

Level against electric shock I I I I I Water-proof grade IPX4 IPX4 IPX4 IPX4 IPX4

Net weight(kg) 165 275 295 495 622 Net size(mm) 1200X920X1255 1200X920X1255 1200X920X1455 2046*1180*1750 2400*1130*2300

Required water flow rate(m3/h) 6 8 8 12 16 Required tank cubage 5-8 7-10 8-12 10-15 15-20

Water connection G1-1/4" G1-1/4" G1-1/4" G2" G2" Operation temp.range(℃) -10-45 -10-45 -10-45 -10-45 -10-45

Noise dB(A) ≤64 ≤65 ≤65 ≤68 ≤68

Test condition *Heating: Ambient temp. (DB/WB):20℃ /15℃, Water temp. (Initial/Final):15℃/55℃.

**Heating: Ambient temp. (DB/WB):7℃/6℃, Water temp. (In/Out):30℃/35℃.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 7: Deron Heat Pump Catalogue

6

● COPELAND scroll compressor R417A. Emerson ALCO expansion valve. FULIHUA fan, aluminum-magnesium durable

fan and Nylon fibre blades, quiet. ● Galvanized steel case with durable powder coating, no-screw design, no rust. ● High purity DuPont refrigerant: R417A, R407C, R410A. ● Model name explanation: C stands for side blowing direction. D stands for the up blowing direction. W stands for the mainframe.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 8: Deron Heat Pump Catalogue

7

1.2 DERON Air to Water Heat Pump Split Type for Cold Area

Suitable for Low Ambient DERON air to water heat pump split type is designed for cold area such as Northern Europe, Northern America. The system is split type, ensuring all water pipes indoor and avoiding freezed to damaged in cold winter. Moreover, the heat pump is optimized to run reliably at -15DegC ambient, creating a warm and comfortable living environment for customers.

Eco-friendly The system uses R410a refrigerant with high purity, equipped with internationally name-brand compressors, ensuring stable operation in low ambient. R410a is an Eco-friendly refrigerant and well recognized in Northern Europe without CO2 emission.

Easy Installation The system is designed for easy installation. The water connections are on top of the indoor unit, convenient.

Low Noise Slower fan with more blades is used for the outdoor unit, optimized for low noise. The indoor unit contains the quiet compressor, with anti-vibration design to reduce the noise to the most extent.

Comprehensive Protection The intelligent controller has all-round protections (or protection function with terminals)to protect the heat pump. l Over-high/low pressure protection l Water flow protection terminal l Compressor heating cable protecton l Circulation pump anti-freezing protection

With Auxiliary Heating Control Terminal The controller is equipped with auxiliary heating terminal. This function is very necessary in cold winter. This function can be enabled or disabled by parameter setting. Settable Defrosting The defrosting temperature is settable according to different climate features, aiming at achieving the best defrosting efficiency.

Use your indoor thermostati!!! The interlock terminal receives on/off signal from the indoor thermostati, thus starts or stanbys the heat pump. This function gives users a trouble-free operation and save more energy for users.

Working Principle: Additional heat

exchanger for daily hot

water is optional

according to

customers’ need.

Timer Function The controller has timer function, starting or stopping the heat pump according to the timer setting by users.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 9: Deron Heat Pump Catalogue

8

DE-27W/DH, DE-46W/DH DE-75W/DH , DE-92W/DH DE-180W/DH, DE-270W/DH, DE-360W/DH DR Series Heat Pump

---- Heat Recovery: Central Heating/cooling + Hot Water

2. Air to Water DR Series Heat Pump: Heat Recovery Heat Pump

● Suitable for providing cooling and hot water(heat recovery) in hot region, suitable for providing heating and hot water in cold region. ● In summer, producing free sanitary water when cooling ● In winter, managing sanitary hot water and central heating synchronously ● With sanitary hot water temperature set value, controlling the hot water circulation pump. ● COPELAND scroll compressor for R417A. Emerson ALCO expansion valve. High efficiency Plate heat exchanger. Nylon fiber durable blades.

DE-27W/DR DE-46W/DR DE-92W/DR DE-180W/DR

Intelligent Indoor Control Panel

High efficiency Plate Type Heat Exchanger Stainless steel

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 10: Deron Heat Pump Catalogue

9

Model DE-27W/DR DE-36W/DR DE-46W/DR DE-27W/DR DE-36W/DR Power supply(V/ph/Hz) 220/1/50 220/1/50 220/1/50 380/3/50 380/3/50 * Cooling capacity(kw) 7 9.6 12 7 9.6 *Cooling capacity(BTU) 23800 32700 40900 23800 32700

* Cooling power input(kw) 2.5 3.3 4.3 2.5 3.3 ** Heating capacity(kw) 8 10.5 13.5 8 10.5

** Heating capancity(BTU) 27300 35800 46000 27300 35800 ** Heating power input(kw) 2.7 3.6 4.6 2.7 3.6

*** Heating capacity(kw) 11.2 15 19.3 11.2 15 *** Heating capacity(BTU) 38200 51200 65800 38200 51200

*** Heating power input(kw) 2.7 3.6 4.6 2.7 3.6 Max.current(A) 19.5 26 33 7.5 10

Refrigerant R417A/R407C/R410A Refrigerant weight(g) 2800 3500 3500 2800 3500

Level against electric shock I I I I I Water-proof grade IPX4 IPX4 IPX4 IPX4 IPX4

Net weight(kg) 115 150 150 115 150 Net size(mm) 700X690X860 800X780X1000 800X780X1000 700X690X860 800X780X1000

Water connection G1" G1" G1" G1" G1" Operation temp.range(℃) -10-45 -10-45 -10-45 -10-45 -10-45

Noise dB(A) ≤62 ≤64 ≤64 ≤62 ≤64

Test condition *Cooling:Ambient temp.(DB/WB)35 /24℃ ℃;Water temp.(In/Out):12 /7℃ ℃ **Heating:Ambient temp.(DB/WB)7 /6℃ ℃;Water temp.(In/Out):40 /45℃ ℃

***Sanitary:Ambient temp.(DB/WB)20 /15 ;℃ ℃ Hot water temp.(Initial/Final): 15 /55℃ ℃

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 11: Deron Heat Pump Catalogue

10

Model DE-46W/DR DE-92W/DR DE-150W/DR DE-180W/DR

Power supply(V/ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50 * Cooling capacity(kw) 12 25 40 50 *Cooling capacity(BTU) 40900 85300 136500 170600

* Cooling power input(kw) 4.3 8.6 13.2 17.1 ** Heating capacity(kw) 13.5 28 45 56

** Heating capancity(BTU) 46000 95500 153500 191000 ** Heating power input(kw) 4.6 9.2 13.8 18 *** Heating capacity(kw) 19.3 38.5 62 81

*** Heating capacity(BTU) 65800 131300 211500 276300 *** Heating power input(kw) 4.6 9.2 18 18

Max.current(A) 13 25 37 49 Refrigerant R417A/R407C/R410A

Refrigerant weight(g) 3500 3500*2 3500*4 3500*4 Level against electric shock I I I I

Water-proof grade IPX4 IPX4 IPX4 IPX4 Net weight(kg) 150 280 662 662 Net size(mm) 800X780X1000 1200X920X1255 2400*1130*2300 2400*1130*2300

Water connection G1" G1-1/4" G2" G2" Operation temp.range(℃) -10-45 -10-45 -10-45 -10-45

Noise dB(A) ≤64 ≤65 ≤68 ≤68

Test condition Cooling:Ambient temp.(DB/WB)35℃/24℃;Water temp.(In/Out):12℃/7℃

Heating:Ambient temp.(DB/WB)7℃/6℃;Water temp.(In/Out):40℃/45℃

Sanitary:Ambient temp.(DB/WB)20℃/15℃;Hot water temp.(Initial/Final): 15℃/55℃

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 12: Deron Heat Pump Catalogue

11

System Diagram of DR series heat pump

5 modes to satisfy your need:

A: central cooling & sanitary hot water

B: central heating & sanitary hot water

C: single central cooling

D: single central heating

E: single sanitary hot water

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 13: Deron Heat Pump Catalogue

12

3. Household Heat Pump with Built-in GRUNFOS Pump

Features: ● Can be connected with solar heating system as a back up heater. ● Already with circulation pump, no need to install another circulation pump. ● With timer function, connection to indoor thermostat, terminal for auxiliary heater. ● Ultra quiet FULIHUA fan. ● High COP. ● With indoor control panel, convenient. ● 4-way-valve revert circuit defrosting, with adjustable defrosting setting according to

New design! More popular!!!

New case for DE-13WB, 18WB, 27WB,36WB

DE-13WB, 18WB, 27WB,36WB

Basic Device Compact design of this heat pump completely with components listed below:

7

Threaded coaxial coil, largely increasing efficiency!

1) Circuit board 2) Grundfos water pump 3) Coaxial coil heat exchanger 4) FULIHUA Low Noise Fan 5) Compressor 6) Suction accumulator 7) Deron remote controller indoor.

DE-46WB

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 14: Deron Heat Pump Catalogue

13

Model DE-13WB DE-18WB DE-27WB DE-36WB DE-46WB Power supply(V/ph/Hz) 220/1/50 220/1/50 220V/1(380/3)/50 220V/1(380/3)/50 380/3/50 *Heating capacity(kw) 5.2 7.2 10.8 14.4 18.4

*Heating capacity(BTU) 17700 24560 24550 49130 62780 Rated power input(kw) 1.3 1.8 2.7 3.6 4.6 **Heating capacity(kw) 4 5.5 8.3 11 14.2

**Heating capacity(BTU) 13600 18700 28160 37830 48340 Rated power input(kw) 1.1 1.6 2.2 3 3.8 Water feed speed(L/h) 110 155 232 310 395

Max.current(A) 9.5 13 19.5/ or 7.2 25 or 10 13 Refrigerant R417A/R407C/R410A

Refrigerant weight(g) 1200 1500 2000 2300 2500 Level against electric shock I I I I I

Water-proof grade IPX4 IPX4 IPX4 IPX4 IPX4 Net weight(kg) 58 67 84 95 110 Net size(mm) 790*270*760 790*270*760 830*310*960 880*360*1050 1120*425*1260

Required water flow rate(m3/h) 1.2 3 2 3 4 Water connection G3/4" G3/4" G1" G1" G1"

Operation temp.range(℃) -10-45 -10-45 -10-45 -10-45 -10-45 Noise dB(A) ≤48 ≤48 ≤48 ≤50 ≤52

Test Condition *Heating:Ambient temp.(DB/WB):20℃/15℃; Water temp.(Initial/Final):15℃/55℃ ;

**Heating:Ambient temp.(DB/WB)7℃/6℃; Water temp.(In/Out)30℃/35℃ . ● Panasonic Rotary/Copeland scroll compressor. Emerson expansion valve. Grunfos circulation pump. High purity DuPont refrigerant. ● Threaded coaxial coil heat exchanger, galvanized phydrophilic fin-tube evaporator. ● The data above are based on R417A. We also produce these models with R407C or R410A.

Household Heat Pump with Coaxial Coil and Grunfos Pump Datasheet (50Hz/60Hz) Heating capacity from 4.8 to 17.88KW

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 15: Deron Heat Pump Catalogue

14

4. DERON AIR-TO-WATER DW SERIES HEAT PUMP

(Ambient temp. from-25℃~45℃)

Description: DW series heat pump is specially designed for high water temperature hot water out put and available for low air temperature working in. DW series heat pump is specially designed according to cold climate features. Its core philosophy is to solve the user’s home eating during the cold climate in winter and spring, to make cooling in hot summer and autumn. By using Copeland new designed compressor, with Deron specially designed economizer and high efficiency has greatly improved. So the performance of the heat pump comes to a new height. According to the testing and validation, this type heat pump has a COP at -15℃ can reach 2.4, and available for 65℃ hot water output and safely working in -25℃outside air temperature. DE-27W/DW DE-46W/DW DE-92W/DW DE-180W/DW

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 16: Deron Heat Pump Catalogue

15

Main components: l Compressor: Copeland new designed scroll compressor with gas injection increase enthalpy can get a more high efficiency. l Heat exchanger: Stainless steel plate heat exchanger & Coaxial Coil heat exchanger. l Evaporator: Hydrophilic high efficiency fin-tube evaporator. l Expansion valves: Main thermal expansion valves & Spray thermal expansion valves. l Electromagnetic valve: Emerson electromagnetic valve. l Fan: FULIHUA fan with nylon fibred blades, durable, lower noise, longer life.

Strong points: l Hot water output temperature up to 65℃. l Suitable for cold area, safely working in -25℃ ambient temperature. l COP can be up to 2.4, at -15℃. l Eco-friendly refrigerant: R417A. l Automata tic defrosting function included (with reverse cycle valve inside). l Anti-corrosion case: durable coating; no-screw design with stainless steel bolts and nuts, no rust. l General testing and operational test carried out for every before package in the factory. l Comprehensive protection, --- ensures trouble free operation in extremely cold ambient.

1. Anti-freezing protection, 2.Water flow protection, 3.Over high pressure protection, 4.Over low pressure protection etc.

DE-46W/DW exhibited on the 108th Canton Fair.

Deron Intelligent Remote Controller

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 17: Deron Heat Pump Catalogue

16

Specified parameter list Model DE-27W/DW DE-46W/DW DE-92W/DW DE-180W/DW DE-270W/DW DE-360W/DW

Power supply (V/ph/Hz) 220/1/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 *Heating capacity(kW) 11.6 19.8 39.5 81 121.5 162 *Rated power input (kW) 2.7 4.6 9.2 18 27 36 Water feed speed (L/h) 250 425 850 1665 2495 3328

**Heating capacity(kW) 6 10.2 20.5 40.3 60.4 80.5 **Rated power input (kW) 2.5 4.3 8.5 16.8 25.1 33.5 Water feed speed (L/h) 129 219 440 866 1298 1730

***Heating capacity(kW) 4.6 7.9 15.8 31 46.5 61.9 ***Rated power input (kW) 2.6 4.4 8.8 17.2 25.9 34.4

Water feed speed (L/h) 98 170 340 666 1000 1330 Refrigerant R417A/R407C/R410A

Refrigerant weight (g) 2000 2500 2500*2 2500*4 2500*6 2500*8 Max. current (A) 18.5 13 25 49 73.5 98

Rated water temp. (℃) 55 55 55 55 55 55 Max. water temp. (℃) 60 60 60 60 60 60

Level against electric shock I I I I I I Water-proof grade IPX4 IPX4 IPX4 IPX4 IPX4 IPX4

Net weight (Kg) 130 175 320 680 960 1600 Net size (mm) 800X700X1000 800X700X1150 1200X920X1455 2400X1130X2300 2400X1400X2300 2400X2260X2300

Required water flow rate (m3/h) 2.2 4 8 16 24 32 Required tank cubage (t) 2-3 3-5 7-10 15-20 25-30 35-40

Water connection G1" G1" G1-1/4" G2" G3" G3" Operation temp. range (℃) -25-45 -25-45 -25-45 -25-45 -25-45 -25-45

Noise dB (A) ≤60 ≤64 ≤65 ≤68 ≤68 ≤68

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 18: Deron Heat Pump Catalogue

17

Specified parameter list Comparison of -25℃ heat pump & normal heat pump

Difference DE-27W/D(normal)

DE-27W/DW(-25C heat

pump) DE-46W/D(normal)

DE-46W/DW (-25C heat

pump)

DE-92W/D(norm

al)

DE-92W/DW(-25C heat

pump)

Evaporator Standard 3HP Double row 3HP Standard 5HP 6HP Standard 10HP 12HP

Compressor ZR34KH-PFJ-522

ZW30KS-PFS (With

gas injection increase

enthalpy scroll

compressor)

ZR61KH-TFD-522

ZW61KS-TFP (With gas

injection increase enthalpy

scroll compressor)

2*ZR61KH-TFD-

522

2*ZW61KS-TFP (With gas

injection increase enthalpy

scroll compressor)

Thermal expansion

valves

Thermal expansion

valves

(BAE1-1/2HW100)

Main thermal

expansion

valves(BAE1-1/2HW100

) & Spray thermal

expansion valves

( BAE1HCA)

BAE5HCA

Main thermal expansion

valves(BAE3HW100) &

Spray thermal expansion

valves ( BAE2HCA)

BAE5HCA

2* Main thermal expansion

valves(BAE3HW100) & 2*

Spray thermal expansion

valves

( BAE2HCA)

Plate heat

exchanger No BL20-12D No BL20-16D No 2*BL20-16D

Electromagnetic

valve No

2* Emerson

electromagnetic valve No

2* Emerson electromagnetic

valve No

4*Emerson electromagnetic

valve

Liquid storage pot No KFR120WLG01 No KFR120WLG01 No 2*KFR120WLG01

Operation temp.

Range(℃) -10~43 -25~43 -10~43 -25~43 -10~43 -25~43

COP(at +20℃) 4.1 4.2 4.1 4.2 4.1 4.2

COP(at -15℃) <1.5 2.4 <1.5 2.4 <1.5 2.4

COP(at -25℃)

cannot work 1.8 cannot work 1.8 cannot work 1.8

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 19: Deron Heat Pump Catalogue

18

5.1. Water to Water Heat Pump Standard Type (Domestic or Commercial)

DE-27W/S, DE-46W/S DE-27W/S, DE-36W/S,DE-46W/S, DE-52W/S, DE-150W/S, DE-180W/S Stainless steel DE-75W/S, DE-92W/S

● Safe: Water-electricity separation technology, completely safe. ● Long life: Service life reach up to 15 years. Low maintenance cost. 。 ● Modular design available. ● High COP up to 4.4 at W15/W40. ● With auxiliary heating control terminal and circulation pump control terminal. ● Suitable for water source or brine source with glycol. ● Quiet: low noise design for indoor installation, with noise insulation inside the case. ● Anti-corrosion: durable coating; special case design by using stainless steel bolts and nuts, no screws, no damage to the coating, no rust happen.

Stainless steel Plate heat exchanger

Noble Case! European Style! Light-touch pad control panel

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 20: Deron Heat Pump Catalogue

19

Water to Water Heat Pump Standard Type Datasheet

Model DE-27W/S DE-36W/S DE-46W/S DE-36W/S DE-46W/S DE-52W/S Power(V/ph/Hz) 220/1/50 220/1/50 220/1/50 380/3/50 380/3/50 380/3/50

* Heating capacity(kw) 12.5 16.5 21 16.5 21 24 * Heating capacity(BTU) 42600 56300 71600 56300 71600 81800 * Rated power input(kw) 2.7 3.6 4.6 3.6 4.6 5.2 ** Heating capacity(kw) 11.5 15 19 15 19 22.5

** Heating capacity(BTU) 39200 51200 64800 51200 64800 76700 **Rated power input(kw) 2.3 3 3.8 3 3.8 4.5 *** Heating capacity(kw) 8.5 11.0 14.0 11.0 14.0 17.0

*** Heating capacity(BTU) 29000 37500 47800 37500 47800 58000 ***Rated power input(kw) 2.3 3 3.8 3 3.8 4.5

Refrigerant R417A/R407C/R410A Refrigerant weight(g) 1600 2200 2500 2200 2500 2800

Max current(A) 19.5 26 33 10 13 15 Rated water temp.(℃) 55 55 55 55 55 55 Max.water temp.(℃) 60 60 60 60 60 60

Level against electric shock I I I I I I Water-proof grade IPX4 IPX4 IPX4 IPX4 IPX4 IPX4

Net weight(kg) 80 100 120 100 120 140 Net size(mm) 600*470*830 600*620*830 600*620*830 600*620*830 600*620*830 600*620*830

Packing size(mm) 680*550*930 680*700*930 680*700*930 680*700*930 680*700*930 680*700*930 Required hot water flow rate(m3/h) 2.2 3.2 4 3.2 4 4.8

Required water source flow rate(m3/h) 1.8 2.45 3.2 2.4 3.2 3.8 water connection G1" G1" G1" G1" G1" G1"

Noise dB(A) ≤40 ≤40 ≤42 ≤40 ≤42 ≤42

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 21: Deron Heat Pump Catalogue

20

● COPELAND flexible scroll compressor for R417A., Sanyo or Daikin scroll compressor for R407C and R410a.

●Emerson ALCO expansion valve. ● High efficiency Plate Type heat exchanger. ● High purity DuPont refrigerant. ● Models mark in red have got CE.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 22: Deron Heat Pump Catalogue

21

5.2 Water to Water Heat Pump SH Series: Central Heating +

Daily Hot Water (Domestic Type)

Deron SH series water to water heat pump is designed to provide an all-round solution for house, including central heating and daily hot water heating, completely taking the place of traditional boilers, saving more cost for users than normal water-water heat pumps do.

3 Operation modes There are 3 operation modes in the SH series controller: Mode 1: central heating only, with set value for the water temperature, with the circulation pump control terminal. Mode 2: daily hot water only, with set value for the daily hot water temperature, with the circulation pump control terminal. Mode 3: central heating + daily hot water. Circulation pump stops after its own water cycle reaches the set value. The compressor stops only after both water cycles are satisfied. The heat pump starts again as long as either cycle requires heating.

Comprehensive Protection The intelligent controller has all-round protections (or protection function with termincals)to protect the heat pump. l Over-high pressure protection l Over-low pressure protection l Water flow protection terminal l Compressor heating cable protecton l Circulation pump anti-freezing protection

With Auxiliary Heating Control Terminal The controller is equipped with auxiliary heating terminal for the central heating cycle. This function is very necessary in cold winter. This function can be enabled or disabled by parameter setting.

Noble Appearance l The design is completely a household application style in

European market. l The control panel is light-touch pad type. l Invisible-screw design.

Easy Installation All water connections come out from the top panel, allowing the heat pump placed in any corner inside the house. Storage room or basement is the ideal installation place.

Low Noise The whole heat pump is optimized to reduce vibration at the most extent to reduce the noise. Anti-vibration piping design, with noise insulation inside the case, ensures the noise level as low as down to 35dBA of model DE-27W/SH.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 23: Deron Heat Pump Catalogue

22

Water to Water Heat Pump SR series Datasheet

● COPELAND flexible scroll compressor for R417A., Sanyo scroll compressor for R407C and R410a. ● Emerson ALCO expansion valve. ● High efficiency Plate Type heat exchanger. ● High purity DuPont refrigerant.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 24: Deron Heat Pump Catalogue

23 Grey Yellow Stainless Steel Champagne Outdoor unit

Controller

6.1 Household Heat Pump Water Heater Split Type ● Hot water outlet up to 60 ℃. ● High COP up to 4.6. High efficiency tank heat insulation, extremely low heat loss. ● Durable: Service life can reach up to 15 years. Low maintenance cost. ● Safe: water-electricity separation technology, no creepage, completely safe. ● All weather operation: Stable operation without being influenced by weather, even snow or rain. ● Environment friendly: No pollution or waste discharged in entire working cycle. ● Fashionable: The design is fashionable with durable coating in different colors, perfectly matching your house style. ● Simple installation: It can be placed on the roof top, balcony, yard, or basement, no special room necessary. ● Quiet: Low noise, no disturbance to owners and neighbors.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 25: Deron Heat Pump Catalogue

24

Household Heat Pump Water Heater Split Type Datasheet (50Hz) Heating capacity from 3.6 to11.3KW

● Panasonic Rotary compressor. Emerson expansion valve. ● The data above are tested at ambient temperature 20℃,input water 15℃,output water 55℃. ● The meaning of the letters: L stands for liter.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 26: Deron Heat Pump Catalogue

25

6.2 Household Heat Pump Water Heater Integrative Type [All in One]

● Suitable for -10℃~+45℃ ambient temperature. ● Efficient: High COP, high efficiency heat insulation for the inside cylinder, extremely low heat loss. ● Reliable: Service life can reach up to 15 years. Low maintenance cost. ● Durable: With stainless steel case and high qualified compressor. Long service life can reach up to 15 years. ● All weather operation: Stable operation without being influenced by weather, even snow or rain. ● Environment friendly: No pollution or waste discharged to entire working surrounding. ● Economic: The running costs of Deron heat pump can be 80% less than that of a traditional gas boilers. ● Simple installation: It can be placed on the roof top, balcony, yard, or basement, no special room necessary.

Deron Intelligent Remote Controller Indoor

A view of the inside

DE-100LY/DE-150LY/DE-200LY

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 27: Deron Heat Pump Catalogue

26

Household Heat Pump Water Heater All in One Type Datasheet (50Hz) Heating capacity 5.3 KW

● Panasonic Rotary compressor. Emerson expansion valve. ● The data above are tested at the ambient temperature 20℃,inlet water 15℃,outlet water 55℃. ● Model name explanation: L stands for litre, Y stands for Integrative.

Model DE-100LY (Cylinder)

DE-150LY (Cylinder)

DE-200LY (Cylinder)

DE-150LY* DE-180LY*

Power Supply(V/Ph/Hz) 220-240/1/50 220-240/1/50 220-240/1/50 220/1/50 Heating Capacity(kw) 5.3 5.3 5.3 5.3 Rated Power (kw) 1.25 1.25 1.25 1.25 Water Production Speed (L/h) 115 115 115 115 Type of Refrigerant R417A/R407C/R 410a Refrigerant Weight(g) 1000 1000 1000 1000 Max. Working Current (A) 8 8 8 8 Rated Heating Temp. (℃) 55 55 55 55 Max. Heating Temp. (℃) 60 60 60 60 Anti-shock Grade I I I I Water Proof Grade IP×4 IP×4 IP×4 IP×4 Outdoor Unit Weight (kg) 73 80 85 102/133 Water Connection G1/2” G1/2” G1/2” G1/2” Ambient Temperature (℃) -10~45 -10~45 -10~45 -10~45 Noise (dB) ≤48 ≤48 ≤48 ≤48

Test condition Ambient:dry/wet bulb 20℃/15℃

Hot water:initial/final temp.15℃/55℃

DE-150LY*/DE-180LY*

DE-150LY*/DE-180LY*

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 28: Deron Heat Pump Catalogue

27

7.1 Domestic Swimming Pool Heat Pump (Titanium Heat Exchanger) With 100% Titanium,eliminating corrosion and maximizing heat transfer efficiency

● Cooperation range: -10℃~+45℃ ambient temperature. ● Safe: Water electricity separation technology, no creepage, completely safe. ● Efficient: Stable performance with high COP up to 5.5. ● Compact: small, taking up little space, easy installation. ● Durable: designed for placed outdoor, resisting all kinds of weather. ● Anti-corrosion case: galvanized steel with durable powder coating. ● With remote wire control panel indoor, completely automatic operation. ● With multiple protections, ensuring long life. ● Return water temperature is pre-set at the range of 28℃~30℃(normal) for swimming pool use, also according to users’ requirement.

Inner 100% titanium, outer PVC, max temp 40℃

Intelligent Remote Controller Indoor

DE-13, 18, 27, 36W/CY

DE-18W/CY exhibited on IFA 2010, Berlin, Germany.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 29: Deron Heat Pump Catalogue

28

● CIE/FULIHUA blower, nylon fibred blades, durable, lower noise, longer life. ● High purity DuPont refrigerant. ● Model name explanation: C stands for the lateral blowing direction. D stands for the top blowing direction. W stands for the mainframe. Y stands for

swimming pool use. J stands for domestic use.

Domestic Swimming Pool Heat Pump Datasheet (50Hz/60Hz)- Inner Titanium Outer PVC Heat Exchanger

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 30: Deron Heat Pump Catalogue

29 DE-27W/DY,DE-46W/DY DE-46W/DY DE-18W/CY, DE-27W/CY,DE-46W/CY DE-92W/DY,DE-180W/DY

7.2 Commercial Swimming Pool Heat Pump (Titanium Heat Exchanger) With 100% Titanium,Tubing to eliminate all corrosion and maximize heat transfer efficiency

● Coperation range: -10℃~+45℃ ambient temperature. ● Safe: Water electricity separation technology, no creepage, completely safe. ● Reliable: Stable performance with high COP up to 6.0. ● Durable: 100% titanium heat exchanger for anti-corrosion from chlorine, long life. ● Designed for placed outdoor, simple installation and replacement. ● Anti-corrosion case: galvanized steel with durable powder coating; no-screw case design, no rust happen. ● With remote wire control panel indoor, completely automatic operation. ● With automatic defrosting, with auxiliary heating control terminal. ● Return water temperature is pre-set at the range of 28℃~30℃(normal) for swimming pool use, also according to users’ requirement.

1. Inner 100% titanium, outer PVC, max temp 40℃ 2. Inner 100% titanium, outer stainless steel, max temp 60℃

Intelligent Remote Controller Indoor

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 31: Deron Heat Pump Catalogue

30

Model DE-27W/DY DE-36W/DY DE-46W/DY DE-52W/DY DE-75W/DY Power supply(V/ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50

Compressor rated power(kw) 2.7 3.6 4.6 5.2 7.5 Heating capacity(kw) 11 14.5 18 22 31

Power input(kw) 1.9 2.7 3.1 3.7 5.5 Refrigerant R417A/R407C/R410A

Refrigerant weigh(g) 1850 2000 2300 2500 2200*2 Max.current(A) 7.5 10 13 15 21

Rated water temp.(℃) 28 28 28 28 28 Level against electric shock I I I I I

Water-proof grade IPX4 IPX4 IPX4 IPX4 IPX4 Net weight(kg) 90 120 130 140 260 Net size(mm) 700*690*860 800*780*1000 800*780*1000 800*780*1000 1200*920*1225

Required water flow rate(m3/h) 4.5 6 7.5 9 12 Water connection(mm) 50mm 50mm 50mm 50mm 63mm

Operation temp.range(℃) -10-45 -10-45 -10-45 -10-45 -10-45 Noise dB(A) ≤60 ≤64 ≤64 ≤64 ≤65

Test condition Ambient temp.(DB/WB):20℃/15℃

Water temp.(Initial/Final):15℃/28℃ l 100% pure Titanium heat exchanger. l COPELAND scroll compressor for R417A. Emerson ALCO expansion valve. l CIE/FULIHUA blower, nylon fibre blades, durable, lower noise, longer life. l Evaporator: galvanized-hydrophilic fin-tube, bigger and wider. High purity imported DuPont refrigerant. l No-screw case design, galvanized coated steel or stainless steel. l Model name explanation: C stands for the lateral blowing direction. D stands for the up blowing direction. W stands for the mainframe. Y stands for

swimming pool use. P stands for the PVC.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 32: Deron Heat Pump Catalogue

31

Model DE-92W/DY DE-105W/DY DE-150W/DY DE-180W/DY DE-225W/DY DE-270W/DY

Power supply(V/ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 Compressor rated power(kw) 9.2 10.5 15 18 22.5 27

Heating capacity(kw) 39 46.5 62 74 110 148 Power input(kw) 6.7 8.2 11.3 13.5 20 27

Refrigerant R417A/R407C/R410A Refrigerant weigh(g) 2300*2 2500*2 2300*3 2300*4 2500*4 3450*4

Max.current(A) 25 30 25 29 37 49 Rated water temp.(℃) 28 28 28 28 28 28

Level against electric shock I I I I I I Water-proof grade IPX4 IPX4 IPX4 IPX4 IPX4 IPX4

Net weight(kg) 250 290 495 622 670 893 Net size(mm) 1200*920*1225 1200*920*1425 2046*1180*1750 2400*1130*2300 2400*1130*2300 2400*1400*2300

Required water flow rate(m3/h) 15 15 18 20 25 30 Water connection(mm) 63mm 63mm 90mm 90mm 110mm 110mm

Operation temp.range(℃) -10-45 -10-45 -10-45 -10-45 -10-45 -10-45 Noise dB(A) ≤65 ≤65 ≤68 ≤68 ≤68 ≤68

Test condition Ambient temp.(DB/WB):20℃/15℃

Water temp.(Initial/Final):15℃/28℃

1. Inner titanium, outer PVC, max temp 40℃

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 33: Deron Heat Pump Catalogue

32

7.3 Spa Heat Pump Datasheet (50Hz/60Hz)- Inner Titanium-steel coil Heat Exchanger

● The data above are tested at ambient temperature 20℃,initial water temp15℃,final water temp 55℃. ● Titanium-steel heat exchanger. Max. water temp. up to 60℃. ● Case design can follow customer’s requirement. ● FULIHUA blower with nylon fibre blades, durable, lower noise, longer life. ● Durable powder coating, no rust. Inner titanium, outer stainless steel, max temp 60℃

● Model name explanation: D stands for the up blowing direction. W stands for the mainframe. C means lateral blowing direction. P means for spa use.

Model DE-13W/CYS DE-18W/CYS DE-27W/CYS DE-27W/CYS DE-36W/CYS DE-46W/DYS KW 4.8 7.2 10.8 10.8 14.4 18.4

Heating Capacity BUT/h 16500 25000 36800 36800 49200 62800

Power Input KW 1.3 1.8 2.7 2.7 3.6 4.6 COP 3.7 4.0 4.0 4.0 4.0 4.0 Power Supply V/ph/Hz 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50

Type Rotary Rotary Rotary Scroll Scroll Scroll Compressor

Qty 1 1 1 1 1 1 Refrigerant R417A/R407C / R410A Condenser 100% titanium-steel coil shell heat exchanger Throttling Device Emerson ALCO thermostatic expansion valve Evaporator Galvanized hydrophilic fin-tube heat exchanger Fan Blowing Type Lateral blowing Top blowing Water Flow Volume M3/h 1.8 2.0 2.8 3.0 3.5 4.0 Water Connection Фmm 48 48 48 48 48 60

material Powder coating steel Case

mm White, grey or any other color according to customer’s need. Operation Range ℃ 1000*300*620 1000*300*620 1120*425*710 1120*425*710 1120*425*710 800*780*1000 Noise dB(A) 50 52 54 54 56 57

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 34: Deron Heat Pump Catalogue

33

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 35: Deron Heat Pump Catalogue

34

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 36: Deron Heat Pump Catalogue

35

l While you are considering We provide free consolation on the model of heat pump system, system design, and cost estimation that can be suit

for your needs.

l After you purchase the product The first installation can be carried out by us, by sending engineers to your country helping you with the installation, in a safe and efficiency manner. Not familiar with how to work with the system yet? Don’t worry, we offer training on how to operate the system so that you can make the best use of your heat pump.

l Satisfaction guarantee: There is an 18 months warrantee for air-to-water heat pumps and water-to-water heat pumps, and 24 months warrantee

for swimming pool heat pumps.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 37: Deron Heat Pump Catalogue

36

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 38: Deron Heat Pump Catalogue

37

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 39: Deron Heat Pump Catalogue

38

Guangzhou Deron Heat Source Facilities Co., Ltd. Deron · Export Department Zhongping Ave,Zhongcun Town,Panyu Dist,511495 Guangzhou,China Phone: +86 20 22883030 Fax: +86 20 28685651 Mail:[email protected] Skype:deronheatpump MSN:[email protected] www.deronheatpump.com/ deron.en.alibaba.com/

OE

M orders are w

elcomed

Trade Shows: 1) PISCINA BCN 2011 Barcelona, Spain 2) InterSolar 2011 Munich, Germany 3) ISH 2011 Frankfurt, Germany 4) Energiespar Messe2011 Austria 5) Home Appliances @IFA -2010 Berlin, Germany 6) The 105th China Import & Export Fair (Canton Fair); April 15th-19th, 2009; Guangzhou, China 7) The 6th China International SME Fair & China-Spain SME Fair; September 22th-25th, 2009; Guangzhou, China 8) The106th China Import & Export Fair (Canton Fair); October 15th-19th, 2009; Guangzhou, China 9) The 6th China-ASEAN Expo; October 20th-24th, 2009; Nanning, China 10) The 2010MIECF Macao International Environmental Co-operation Forum & Exhibition; April 8th-10th, 2010; Macao, China 11)The IFA Exhibition; November 4th-9th, 2010; Berlin, Germany 12)The108th China Import & Export Fair (Canton Fair); 12)The110th China Import & Export Fair (Canton Fair); 13)PISCINA BCN 2011 Barcelona, Spain 14) Eco Expo Asia,HK,China

PDF created with pdfFactory Pro trial version www.pdffactory.com