EN Inset appliance Insert burning solid fuel without water supply Jøtul AS Postboks 1411, 1602 Fredrikstad, Norway Tel.: +47 69 35 90 00 E‐mail: [email protected] Performance Fuel Wood logs A1 Minimum distances, in mm Front = 1100 Also see the installation instructions No CO [0,07 %] NOx [85 mg/m3] OGC [49 mgC/m3] PM [26 mg/m3] Pass Pass T [251°C] NPD 6 kW ‐ kW ‐*kW Ƞ [78%] AVCP: Electrical safety Cleanability Maximum water operating pressure Flue gas temperature at nominal heat output Mechanical resistance (to carry a chimney/flue) Thermal output Normal heat output Danish Technological Institute 1235 300‐ELAB‐2345‐EN Test report no: NB‐No: EN 13229:2001/A1:2003/A2:2004 Harmonized technical specification Essential characteristics Fire safety Product Type: Type, batch or serial number: Intended use of the product: Name and Address of the manufacturer: Declaration of Performance (DoP) No. C400‐CPR‐250918 Jøtul C400 Combustable materials inside the surround must be covered by insulation as described in the manual Energy efficiency Reaction to fire Distance to combustible materials Risk of burning fuel falling out Emission of combustion products Surface temperature System(s) of assessment and verification of constancy op performance (AVCP) of the construction product as set out in CPR, Annex V Notified body: System 3 Declared performance: Room heating output Water heating output

Transcript of Declaration of Performance (DoP) · Declaration of Performance (DoP) No. C400‐CPR‐250918 Jøtul...

Page 1: Declaration of Performance (DoP) · Declaration of Performance (DoP) No. C400‐CPR‐250918 Jøtul C400 Combustable materials inside the surround must be covered by insulation as

EN

Inset appliance

Insert burning solid fuel without water supply

Jøtul AS

Postboks 1411, 1602 Fredrikstad, Norway

Tel.: +47 69 35 90 00

E‐mail: [email protected]

Performance

Fuel    Wood logs

A1

Minimum distances, in mm

Front = 1100

Also see the installation instructions

No 

CO [0,07 %]

NOx [85 mg/m3]

OGC [49 mgC/m3]

PM [26 mg/m3]

Pass

Pass

T [251°C]

NPD

6 kW

‐ kW

‐*kW

Ƞ [78%]

AVCP:

Electrical safety

Cleanability

Maximum water operating pressure

Flue gas temperature at nominal heat output

Mechanical resistance (to carry a chimney/flue)

Thermal output

Normal heat output

Danish Technological Institute

1235

300‐ELAB‐2345‐EN Test report no:

NB‐No:

EN 13229:2001/A1:2003/A2:2004Harmonized technical specification

Essential characteristics

Fire safety

Product Type: 

Type, batch or serial number:

Intended use of the product:

Name and Address of the manufacturer:

Declaration of Performance (DoP)

No.  C400‐CPR‐250918

Jøtul C400

Combustable materials inside the surround must be covered 

by insulation as described in the manual

Energy efficiency

Reaction to fire

Distance to combustible materials

Risk of burning fuel falling out

Emission of combustion products

Surface temperature

System(s) of assessment and verification of constancy op 

performance (AVCP) of the construction product as set out in 

CPR, Annex V

Notified body:

System 3

Declared performance:

Room heating output

Water heating output

Page 2: Declaration of Performance (DoP) · Declaration of Performance (DoP) No. C400‐CPR‐250918 Jøtul C400 Combustable materials inside the surround must be covered by insulation as

Espen Løkkevig

R&D Manager

Fredrikstad, 10.10.18(Signature)(Place and date of issue)

Declara�on:

Signed on behalf of the manufacturer:

(Name and function)

The performance of the product in conformity with the declared performance.This declara�on of performance is issued under the sole responsibility of the manufacturer.