DEAD LEGS BIOCIDE TREATMENT
Equipment/PID Location Line number valve
TAGRemarks Done Yes/no
LDG 3000 50 Y
LDT 3001 51 Y
LDT 3002 52 Y
LG 3003 53 Y
LT 3004 54 Y
LT 3005 55 Y
LDG 3010 Y
LDT 3011 Y
LDT 3012 Y
LG1 3013 Y
LG2 3013 Y
LDT 3014 Y
LDT 3015 Y
10'' GH300127 OPEN
10'' GH300128 OPEN
12'' GH300129 Y
12'' GH300130 OPEN
Outlet EC313A to closed drain 2"DF350211 9 Y
1" EC313A body drain cold side 1" 10 Y
Outlet EC313B to closed drain 2"DF350213 11 N
1" EC313B body drain cold side 1" 12 N
Outlet EC313C to closed drain 2"DF350215 13 Y
1" EC313C body drain cold side 1" 14 Y
Outlet EC313D to closed drain 2"DF350217 15 N
1" EC313D body drain cold side 1" 16 N
EC313 A/B/C/D by bass cold side 16"GH300096 17 OPEN
LDG2 3020 Y
LDT 3021 Y
LDT 3022 Y
LG1 3023 Y
LG2 3023 Y
LG3 3023 Y
LT 3024 Y
LT 3025 Y
GX310A suction strainer drain 2"DF350080 20 to be done even if pump not running Y
GX310A discharge drain 2"DF350077 21 to be done even if pump not running Y
GX310A suction vent 1"GH310074 22 to be done even if pump not running N
GX310B suction strainer drain 2"DF350080 23 to be done even if pump not running N
GX310B discharge drain 2" 24 to be done even if pump not running N
GX310B suction vent 1"GH310075 25 to be done even if pump not running N
PDV3201A by pass 2" by pass 26 Y
1"Drain of DS320A inlet 1"DF350292 27 Y
3" drain of outlet water 4"PW320028 28 Y
GX320 discharge to oily water package 4"PW400006 29 Y
try-cock 49 Y
LDG3204A 48 Y
LDT3202A 47 Y
LDT 3201A 46 Y
PDV3201B by pass 2" by pass 30 Y
3" drain of outlet water 4"PW320016 31 Y
EC321 by pass 4"PW320028 32 Y
Oily water U/S EC321 to open Drain 2"DO360079 33 Y
Oily water to sand jet DS400 3"PW400058 34 Y
Oily water to sample box 2"PW400042 35 Y
1"Drain of DS320B inlet 3/4" 36 Y
try-cock 45 Y
LDG3204B 44 Y
LDT3202B 43 Y
LDT 3201B 42 Y
DS401( Vendor PID) Drain D/S LV4007 3/4" 37 Y
GX400A discharge drain to closed drain 1"DF350244 38 Y
GX400B discharge drain to closed drain 1"DF350245 39 Y
GX400B PSV 4012B 1 1/2'' PW400054 Y
GX400A PSV 4012A 2 1/2'' PW400056 Y
CA310 water condensate pot 2'' PW400004 require flexible
GX350A recirculation line 2"DF350222 40 Y
GX350B recirculation line 2"DF350223 41 Y
DEAD LEG WHILE DS 320B BY PASS
GX320: pump stopped
DS320B/1955(02) Mini flow GX320 2"PW320025 In Service
GX320
GX320A suction line 6"PW320016 Drain by 3/4"drain valve
GX320A discharge line 4"PW320018 Drain by 3/4"drain valve
GX320B suction line 6"PW320017 Drain by 3/4"drain valve
GX320B discharge line 4"PW320019 Drain by 3/4"drain valve
Instruction: Flush 2 hours after the beginning of biocide treatment
Location Pump Yes / No
DS300 GX822B
DS301 GX822B
DS302 GX822B
PSV3130A (or B) CANCELLED
DA350 GX822B
Suction
GX722/721A/B GX822B
\\vboxsrv\conversion_tmp\scratch_5\[246832403.xls.ms_office.xls]Dead legs
Injection point of Biocide Treatment
PSV3130: no more biocide required due to bonnet destruction of PSV.
PSV3130A/B
DS300
DS301
EC313A/B/C/D
Skimmed oil pipe
DA350/1866
DS320A/1955(02)
DS302
GX310/1954
DS320A/1955(01/02)
DS320B/1955(02/02)