DDM-Wd config-iSCSI-DX60-80 ework.ppt -...

33
PRIMERGY PRIMERGY PRIMERGY DuplexDataManager ® PRIMERGY DuplexDataManager ® Configuration Examples for ETERNUS DX60 / DX80 (iSCSI) ETERNUS DX60 / DX80 (iSCSI) Windows Server 2003 / 2008 / 2008 R2 Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS December 9, 2009

Transcript of DDM-Wd config-iSCSI-DX60-80 ework.ppt -...

Page 1: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

PRIMERGY PRIMERGY PRIMERGY DuplexDataManager ®

PRIMERGY DuplexDataManager ®DuplexDataManager DuplexDataManager

Configuration Examples for ETERNUS DX60 / DX80 (iSCSI)ETERNUS DX60 / DX80 (iSCSI)

Windows Server 2003 / 2008 / 2008 R2

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS

Windows Server 2003 / 2008 / 2008 R2December 9, 2009

Page 2: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

MultiPathMultiPath

I/O Fault Tolerance by Redundant Fibre Channel Paths

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS1

Page 3: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

MultiPath handles Path Redundancy

MultiPathMultiPathMultiPath handles Path Redundancy

standbystandby

active

PRIMERGY

ETERNUS DXxx

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS2

Page 4: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

Load Balancing Option

MultiPathMultiPathLoad Balancing Option

Channel = 1

LUN 1,3,...

Channel = 0

LUN 1,3,...

LUN 0,2,...

Load Balancing Algorithms:a) AutoBalance load balancing algorithma) AutoBalance load balancing algorithmb) Per LUN selectable path

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS3

Page 5: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

standard configuration

MultiPathMultiPathstandard configuration

LAN

Subnet ANIC #1

Ethernet

LAN

LAN

Subnet B

NIC #1

NIC #2

MultiPath

LAN#2 LAN#1

P0 P1 P0 P1

Cntrl 0 Cntrl 1PRIMERGY XXX

internal disksfor

SYSTEM,... Subnet B Subnet A

1st RAIDDisk Array Controller

Cntrl 0

2nd RAIDDisk Array Controller

Cntrl 1

ETERNUS DX60/80ETERNUS DX60/80

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS4

Page 6: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

one switch configuration

MultiPathMultiPathone switch configuration

LAN

Subnet ANIC #1

Ethernet

LAN

LAN

subnets separated by VLAN

Subnet B

NIC #1

NIC #2

MultiPath

LAN

P0 P1 P0 P1

Cntrl 0 Cntrl 1PRIMERGY XXX

internal disksfor

SYSTEM,... Subnet B Subnet A

1st RAIDDisk Array Controller

Cntrl 0

2nd RAIDDisk Array Controller

Cntrl 1

ETERNUS DX60/80

! not recommended !Switch is single point of failure

ETERNUS DX60/80

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS5

Page 7: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

direct attached (standard)

MultiPathMultiPathdirect attached (standard)

LANLAN

Subnet ANIC #1

Ethernet

LAN

Subnet B

NIC #1

MultiPath

NIC #2

Subnet B Subnet A

P0 P1 P0 P1

1st RAIDDisk Array

Cntrl 0

2nd RAIDDisk Array

Cntrl 1

PRIMERGY XXX

internal disksfor

SYSTEM,...

Subnet B Subnet A

Disk Array Controller

Disk Array Controller

ETERNUS DX60/80

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS6

Page 8: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

direct attached (one controller)

MultiPathMultiPathdirect attached (one controller)

LANLAN

Subnet ANIC #1

Ethernet

LAN

Subnet B

NIC #1

MultiPath

NIC #2

Subnet B Subnet A

P0 P1

1st RAIDDisk Array

Cntrl 0

PRIMERGY XXX

internal disksfor

SYSTEM,...

Subnet B Subnet A

Disk Array Controller

ETERNUS DX60/80! not recommended !

Controller is single point of failure

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS7

Page 9: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

Tips and Tricks

MultiPathMultiPathTips and Tricks

� General Recommendations for MultiPath� General Recommendations for MultiPath� IPv4 should be selected (IPv6 not supported)

� Do not establish multiple connections to one target before MultiPath installation

� For iSCSI boot "spanning tree" must be disabled at the boot NIC's switch port� For iSCSI boot "spanning tree" must be disabled at the boot NIC's switch port

� Check presence and status of all MultiPath Groups� MultiPath status must show Active / Standby� MultiPath status must show Active / Standby� Check Acknowledge Configuration to enable the monitoring of missing paths

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS8

Page 10: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

DuplexWriteDuplexWrite

Highest Data Availability by Mirroring

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS9

Page 11: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

DuplexWrite mirrors Data

DuplexWriteDuplexWriteDuplexWrite mirrors Data

PRIMERGY

mirror

ETERNUS DXxx

original

ETERNUS DXxx

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS10

Page 12: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

Diskload Balancing Option

DuplexWriteDuplexWriteDiskload Balancing Option

block# > boundary

block# < boundary

Diskload Balancing Algorithm:read channel depends on block numberread channel depends on block numberboundary dynamically adjusted

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS11

Page 13: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

direct attached

DuplexWriteDuplexWritedirect attached

LAN

NIC #1

Ethernet

LAN

LAN

NIC #1

DuplexWrite

NIC #2

PRIMERGY XXX

internal disksfor

SYSTEM,... P0 P1

1st RAID

Cntrl 0

P0 P1

1st RAID

Cntrl 0

PRIMERGY XXX 1st RAIDDisk Array Controller

1st RAIDDisk Array Controller

ETERNUS DX60/80 ETERNUS DX60/80

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS12

Page 14: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

one switch configuration

DuplexWriteDuplexWriteone switch configuration

LANLAN

NIC #1

Ethernet

LAN

LANNIC #1

DuplexWrite

LAN

P0 P1

1st RAID

Cntrl 0

P0 P1

1st RAID

Cntrl 0

PRIMERGY XXX

internal disksfor

SYSTEM,...

1st RAIDDisk Array Controller

1st RAIDDisk Array Controller

PRIMERGY XXX

ETERNUS DX60/80 ETERNUS DX60/80

! not recommended !Switch is single point of failure

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS13

Page 15: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

Tips and Tricks

DuplexWriteDuplexWriteTips and Tricks

� General Recommendations for DuplexWrite� General Recommendations for DuplexWrite� IPv4 should be selected (IPv6 not supported)

� For iSCSI boot "spanning tree" must be disabled at the boot NIC's switch port

� Configure DuplexWrite first� Install DDM� Build all DuplexWrite groups and start recovery� ...configure your system and applications

� Check presence and status of all DuplexWrite groups� Check presence and status of all DuplexWrite groups� DuplexWrite status must show Online for all (partner) disks

� Be careful using Disk Administrator� Be careful using Disk Administrator� Never delete a COD partition, delete DuplexWrite group first

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS14

Page 16: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

DuplexDataManagerDuplexDataManager

Highest Storage Availability by DuplexWrite & MultiPath

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS15

Page 17: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

DuplexWrite & MultiPath

DuplexDataManagerDuplexDataManagerDuplexWrite & MultiPath

Location1 Location2

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS16

Page 18: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

standard configuration

DuplexWrite & MultiPathDuplexWrite & MultiPathstandard configuration

LANLAN

NIC #1

Ethernet

LAN

Subnet B

Subnet A

LAN#2 LAN#1

NIC #1

NIC #2

MultiPathDuplexWrite

P0 P1P0 P1

LAN#2 LAN#1

PRIMERGY XXX

internal disksfor

SYSTEM,...

1st RAIDDisk Array Controller

Cntrl 0

1st RAIDDisk Array Controller

Cntrl 0

PRIMERGY XXX

ETERNUS DX60/80ETERNUS DX60/80 ETERNUS DX60/80ETERNUS DX60/80

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS17

Page 19: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

full redundancy

DuplexWrite & MultiPathDuplexWrite & MultiPathfull redundancy

LAN

NIC #1

Ethernet

LAN

LAN

NIC #1

NIC #2

MultiPathDuplexWrite

Subnet B

Subnet A

LAN#2 LAN#1

PRIMERGY XXX

internal disksfor

SYSTEM,...

P0 P1 P0 P1P0 P1 P0 P1

LAN#2 LAN#1

PRIMERGY XXX

1st RAIDDisk Array Controller

Cntrl 0

2nd RAIDDisk Array Controller

Cntrl 1

1st RAIDDisk Array Controller

Cntrl 0

2nd RAIDDisk Array Controller

Cntrl 1

ETERNUS DX60/80ETERNUS DX60/80 ETERNUS DX60/80ETERNUS DX60/80

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS18

Page 20: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

DuplexDataManagerDuplexDataManager

Disaster Resilient Solution

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS19

Page 21: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

MS Cluster & DuplexWrite & MultiPath

Disaster Resilient SolutionDisaster Resilient SolutionMS Cluster & DuplexWrite & MultiPath

Cluster Interconnect

Location1 Location2

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS20

Page 22: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

MS Cluster handles Server Redundancy

Disaster Resilient SolutionDisaster Resilient SolutionMS Cluster handles Server Redundancy

Cluster Interconnect

Location1 Location2

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS21

Page 23: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

MultiPath handles Path Redundancy

Disaster Resilient SolutionDisaster Resilient SolutionMultiPath handles Path Redundancy

Cluster Interconnect

Location1 Location2

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS22

Page 24: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

DuplexWrite mirrors Data

Disaster Resilient SolutionDisaster Resilient SolutionDuplexWrite mirrors Data

Cluster Interconnect

Location1 Location2

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS23

Page 25: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

standard configuration

MS Cluster & MultiPathMS Cluster & MultiPathstandard configuration

Subnet ANIC #1

Ethernet

LAN

LAN

Ethernet

LAN

NIC #1Subnet BSubnet A

NIC #1

NIC #2

MultiPathScsiPort2

NIC #1

NIC #2

MultiPath

Subnet B

LAN#2 LAN#1

P0 P1 P0 P1

Subnet B

PRIMERGY XXX

internal disksfor

SYSTEM,...

Subnet A

PRIMERGY XXX

internal disksfor

SYSTEM,...

1st RAIDDisk Array Controller

Cntrl 0

2nd RAIDDisk Array Controller

Cntrl 1PRIMERGY XXX PRIMERGY XXX

ETERNUS DX60/80ETERNUS DX60/80

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS24

Page 26: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

standard configuration

MS Cluster & DuplexWrite & MultiPathMS Cluster & DuplexWrite & MultiPathstandard configuration

NIC #1

Ethernet

LAN

Subnet A

LAN

Ethernet

LAN

NIC #1Subnet B

NIC #1

NIC #2

MultiPathDuplexWrite

ScsiPort2NIC #1

NIC #2

MultiPathDuplexWrite

LAN#2 LAN#1

PRIMERGY XXX

internal disksfor

SYSTEM,...

P0 P1 P0 P1P0 P1 P0 P1

Subnet B Subnet A

PRIMERGY XXX

internal disksfor

SYSTEM,...

PRIMERGY XXX

1st RAIDDisk Array Controller

Cntrl 0

2nd RAIDDisk Array Controller

Cntrl 1

1st RAIDDisk Array Controller

Cntrl 0

2nd RAIDDisk Array Controller

Cntrl 1PRIMERGY XXX

ETERNUS DX60/80ETERNUS DX60/80 ETERNUS DX60/80ETERNUS DX60/80

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS25

Page 27: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

using switch interconnects

MS Cluster & DuplexWrite & MultiPathMS Cluster & DuplexWrite & MultiPathusing switch interconnects

NIC #1

Ethernet

LAN

Ethernet

LAN

NIC #1Subnet A

LAN

Subnet ALAN #1.1 LAN #1.2NIC #1

NIC #2

MultiPathDuplexWrite

ScsiPort2NIC #1

NIC #2

MultiPathDuplexWrite

Subnet B Subnet BLAN #2.1

LAN #1.1

LAN #2.2

LAN #1.2

switchinterconn.

PRIMERGY XXX

internal disksfor

SYSTEM,...

PRIMERGY XXX

internal disksfor

SYSTEM,...

P0 P1 P0 P1P0 P1 P0 P1PRIMERGY XXX PRIMERGY XXX

1st RAIDDisk Array Controller

Cntrl 0

2nd RAIDDisk Array Controller

Cntrl 1

1st RAIDDisk Array Controller

Cntrl 0

2nd RAIDDisk Array Controller

Cntrl 1

ETERNUS DX60/80ETERNUS DX60/80 ETERNUS DX60/80ETERNUS DX60/80

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS26

Page 28: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

2 switch solution

MS Cluster & DuplexWrite & MultiPathMS Cluster & DuplexWrite & MultiPath2 switch solution

NIC #1

Ethernet

LAN

Ethernet

LAN

NIC #1Subnet A

LAN

Subnet BNIC #1

NIC #2

MultiPathDuplexWrite

ScsiPort2NIC #1

NIC #2

MultiPathDuplexWriteSubnet B Subnet A

Subnet B

switch

LAN #1/2 LAN #1/2

PRIMERGY XXX

internal disksfor

SYSTEM,...

PRIMERGY XXX

internal disksfor

SYSTEM,...

P0 P1 P0 P1P0 P1 P0 P1

switchinterconn.

Subnet A/B Subnet A/B

PRIMERGY XXX PRIMERGY XXX

1st RAIDDisk Array Controller

Cntrl 0

2nd RAIDDisk Array Controller

Cntrl 1

1st RAIDDisk Array Controller

Cntrl 0

2nd RAIDDisk Array Controller

Cntrl 1

ETERNUS DX60/80ETERNUS DX60/80

! configuration not recommended !switch failure would cause outage ofthe dedicated storage

ETERNUS DX60/80ETERNUS DX60/80

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS27

Page 29: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

! Avoid Split Brain Situations !

DuplexDataManagerDuplexDataManager! Avoid Split Brain Situations !

NIC #1

Ethernet

LAN

Ethernet

LAN

NIC #1Subnet A

LAN

Subnet ALAN #1.1 LAN #1.2

single point of failure

NIC #1

NIC #2

MultiPathDuplexWrite

ScsiPort2NIC #1

NIC #2

MultiPathDuplexWrite

Subnet B Subnet BLAN #2.1

LAN #1.1

LAN #2.2

LAN #1.2

PRIMERGY XXX

internal disksfor

SYSTEM,...

PRIMERGY XXX

internal disksfor

SYSTEM,...

P0 P1 P0 P1P0 P1 P0 P1PRIMERGY XXX PRIMERGY XXX

1st RAIDDisk Array Controller

Cntrl 0

2nd RAIDDisk Array Controller

Cntrl 1

1st RAIDDisk Array Controller

Cntrl 0

2nd RAIDDisk Array Controller

Cntrl 1

ETERNUS DX60/80ETERNUS DX60/80 ETERNUS DX60/80ETERNUS DX60/80

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS28

Page 30: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

� Bringup nodeA, and nodeB separately (use ServerStart)

Setting up MS Cluster & DDM (WS 2003)Setting up MS Cluster & DDM (WS 2003)� Bringup nodeA, and nodeB separately (use ServerStart)

� Install Windows Server 2003 including latest update & hotfixes� Install DuplexDataManager on all nodes

� Install and configure all LAN connections

Prim Prim

� Install and configure all LAN connections� Configure NICs and switches� Configure the iSCSI SW target

� Configure the Storages� Shut down all but nodeA� Configure LUNs pairwise on both storages (DuplexWrite groups)� Register all nodes for each path

� Create DuplexWrite groups

Prim Prim

� Create DuplexWrite groups� Shut down all but nodeA� Create all DuplexWrite groups on storageA (no mirror disks)� Add second disks at storageB and start recover� Reboot this node (nodeA)

� Install Microsoft Cluster Services� Install MSCS on nodeA (nodeB off)� Install MSCS on nodeB (cluster installation - join)

Prim Prim

� Install MSCS on nodeB (cluster installation - join)� Check DDM and cluster functionality

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS29

Page 31: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

� Bringup all nodes separately (use ServerStart)

Setting up MS Cluster & DDM (WS 2008)Setting up MS Cluster & DDM (WS 2008)� Bringup all nodes separately (use ServerStart)

� Install Windows Server 2008 including latest update & hotfixes� Install DuplexDataManager on all nodes

� Install and configure all LAN connections

Prim Prim

� Install and configure all LAN connections� Configure NICs and switches� Configure the iSCSI SW target

� Configure the Storages� Configure LUNs pairwise on both storages (DuplexWrite groups)� Register all nodes for each path

� Create DuplexWrite groups� Shut down all but one node

Prim Prim

� Shut down all but one node � Create all DuplexWrite groups� Add second disks (do not start recover, status is Online - Error)� Reboot this node, start all other nodes

� Add the feature Failover Clustering� Start the Failover Cluster Management, select Validate a Configuration

Evaluate the cluster validation log (do not proceed until it is error free)

� Create the Failover ClusterPrim Prim

� Create the Failover Cluster� Recover all DuplexWrite groups on the node which owns the disk resource� Create all partitions on the cluster disk resources (DuplexWrite groups)� Acknowledge the MultiPath configuration on all nodes

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS30

� If all DuplexWrite groups are Online test the functionality(e.g. Path failover, moving resources to other nodes, ... )

� Install the Failover Clustering applications.

Page 32: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

Documentation

DuplexDataManagerDuplexDataManagerDocumentation� General hint: read the related documents !

� Contained on DDM-CD:� Readme� Online help ( newest / best reference ! )� Configuration slides

� DDM related links:� DDM related links:� DDM's home (Intranet)

http://synergy.pdb.fsc.net/> DuplexDataManager

� Partners (Corporate Extranet)� Partners (Corporate Extranet)https://partners.ts.fujitsu.com/com/products/servers/primergy/haproducts/Pages/default.aspx> Partner Portal > Product catalog > Server products > Industry standard > High availabiliy

� Online Manuals (Internet)http://manuals.ts.fujitsu.com/> Industry Standard Servers > Software > Select High Availability > Select PRIMERGY DuplexDataManager > Industry Standard Servers > Software > Select High Availability > Select PRIMERGY DuplexDataManager

� PRIMERGY clustering and disaster tolerance (Internet)http://ts.fujitsu.com/products/software/cluster_technology/primergycluster.html> Server High Availability > High availability software for: PRIMERGY servers

� DuplexDataManager updates (Internet)� DuplexDataManager updates (Internet)http://support.ts.fujitsu.com/com/support/index.html> SUPPORT > Driver & Downloads > Full text search Software; Search: DuplexDataManager, MultiPath or MPIO

� PRIMERGY servers (Internet)http://ts.fujitsu.com/products/standard_servers/

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS31

� Disk storage systems (Internet)http://ts.fujitsu.com/products/storage/disk/

� MS Cluster documentation

Page 33: DDM-Wd config-iSCSI-DX60-80 ework.ppt - Fujitsumanuals.ts.fujitsu.com/file/9007/ddm-config-iscsi-eternus-ug-en.pdf · Install MSCS on nodeB ... Start the Failover Cluster Management,

ETERNUS DX60 / DX80 (iSCSI)

AppendixAppendixETERNUS DX60 / DX80 (iSCSI)

C0 C1P0 P1 P0 P1

P0 P1 P0 P1

Cntrl 0 Cntrl 1

1st RAIDDisk Array Controller

2nd RAIDDisk Array Controller

ETERNUS DX60/80

Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS32