DCNNG Multi CCU System Setup

8
1 DCNNG MCCU System Setup ST/PRM3-EU | | 12.Mar.0 7 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Communications Systems DCN Next Gen DCN Next Gen DCNNG Multi CCU System Setup

description

DCNNG Multi CCU System Setup. DCNNG Multi CCU System Setup. A basic multi-CCU system. The following can be connected to a multi-CCU system: A maximum of 30 DCN-CCU devices. A maximum of 4000 delegate positions (Stand-alone and Microphone function only). - PowerPoint PPT Presentation

Transcript of DCNNG Multi CCU System Setup

Page 1: DCNNG Multi CCU System Setup

1 DCNNG MCCU System SetupST/PRM3-EU | |12.Mar.07 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Communications Systems DCN Next GenDCN Next Gen

DCNNG Multi CCU System Setup

Page 2: DCNNG Multi CCU System Setup

2 DCNNG MCCU System SetupST/PRM3-EU | |12.Mar.07 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Communications Systems

DCNNG Multi CCU System Setup

A basic multi-CCU system.

• The following can be connected to a multi-CCU system:

- A maximum of 30 DCN-CCU devices.

- A maximum of 4000 delegate positions (Stand-alone and Microphone function only).

- A maximum of 1500 delegate positions with PC control.

- A maximum of 32 audio channels (1 Floor and 31 channels for Interpretation).

Page 3: DCNNG Multi CCU System Setup

3 DCNNG MCCU System SetupST/PRM3-EU | |12.Mar.07 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Communications Systems

AutoDome

RS 232

For redundancy only

Seat 246 Seat 490

CCU 2

Seat 1

CCU 1

Seat 245

OptionalPC

ControlEthernet link

DCNNG Multi CCU System with 490 Concentus units

Up to 245 addresses can be connected to one CCU. All active units use an address. (Concentus Units are active units)

DCN-NCO

Page 4: DCNNG Multi CCU System Setup

4 DCNNG MCCU System SetupST/PRM3-EU | |12.Mar.07 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Communications Systems

AutoDome

RS 232

Audio Expander

CCU 2

Seat 246 Seat 426 IDESK 1 IDESK 64

CCU 1

Seat 1 Seat 245

OptionalPC

ControlEthernet link

DCNNG Multi CCU System with 426 Concentus units and 64 Interpreter Desks

Up to 245 addresses can be connected to one CCU. All active units use an address. (Concentus Units and Interpreter desks are both active units)

DCN-NCO

Page 5: DCNNG Multi CCU System Setup

5 DCNNG MCCU System SetupST/PRM3-EU | |12.Mar.07 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Communications Systems

DCNNG Multi CCU System with 490 Concentus units and # Interpreter Desks

Up to 245 addresses can be connected to one CCU. All active units use an address. (Concentus Units and Interpreter desks are both active units)

1 n

Seat 1 Seat 245

Seat 246 Seat 490

DCN-NCO

CCU 1

CCU 2

CCU 3

AutoDome

RS 232

OptionalPC

ControlEthernet link

Page 6: DCNNG Multi CCU System Setup

6 DCNNG MCCU System SetupST/PRM3-EU | |12.Mar.07 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Communications Systems

CCU 3

1 n 1 n

Room 3

CCU 2

1 n 1 n

Room 2

DCNNG Multi CCU System Single Room or combined Rooms

Up to 245 addresses can be connected to one CCU. All active units use an address. (Concentus Units and Interpreter desks are both active units) Interlock between booths on separate CCU‘s cannot be used in “None” - mode.

DCN-NCO

CCU 1

1 n 1 n

Room 1

Page 7: DCNNG Multi CCU System Setup

7 DCNNG MCCU System SetupST/PRM3-EU | |12.Mar.07 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Communications Systems

DCNNG Multi CCU System up to 1225 seats

Up to 245 addresses can be connected to one CCU. DCN Dual Delegates Units use an address. Each unit controls two seat numbers.

Seat 1 & 2

Seat 979 & 980

Seat 489 & 490

Seat 491 & 492

Unit 1 Unit 245

Unit 1 Unit 245

DCN-NCO

CCU 1

CCU 2

CCU 3

Seat 1224 & 1225Seat 981 & 982

Unit 1 Unit 245

AutoDome

RS 232

OptionalPC

ControlEthernet link

Page 8: DCNNG Multi CCU System Setup

8 DCNNG MCCU System SetupST/PRM3-EU | |12.Mar.07 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Communications Systems

DCNNG Multi CCU System Setup

End of section

MCCU Menu