DC16 071A. 438-483 kW (500-540 kVA) · SCANIA POWER GENERATION ENGINEs DC16 071A. 438-483 kW...
Transcript of DC16 071A. 438-483 kW (500-540 kVA) · SCANIA POWER GENERATION ENGINEs DC16 071A. 438-483 kW...
SCANIA POWER GENERATION ENGINEs
DC16 071A. 438-483 kW (500-540 kVA)EU stage IIIA
Standard equipment• ScaniaEngineManagementSystem,EMS• Unitinjectors,PDE• Turbocharger• Fuelfilterandextrapre-filterwithwater
separator• Oilfilter,fullflow• Centrifugaloilcleaner• Oilcooler,integratedinblock• Oilfiller,invalvecover• Deepfrontoilsump• Oildipstick,inblock• Magneticdrainplugforoildraining• Starter,1-pole7.0kW• Alternator,1-pole100A• Flywheel,SAE14• Siluminflywheelhousing,SAE1flange• Front-mountedenginebrackets• EGRsystem• Opencrankcaseventilation• Operator’smanual
Optional equipment• Coolingpackage• Fans• Side-mountedPTO• Exhaustconnections• Instrumentpanel• Engineheater• Stiffrubberenginesuspension• Aircleaner• Closedcrankcaseventilation• Studsinflywheelhousing• Lowcoolantlevelreaction• Finetunepotentiometer• Rampstartdelay• Rampuprate
TheenginesforpowergenerationfromScaniaarebasedonarobustdesignwitha
strengthoptimisedcylinderblockcontainingwetcylinderlinersthatcaneasilybe
exchanged.Individualcylinderheadswith4valvespercylinderpromotesrepairability
andfueleconomy.
TheengineisequippedwithaScaniadevelopedEngineManagementSystem,EMS,
inordertoensurethecontrolofallaspectsrelatedtoengineperformance.
Theinjectionsystemisbasedonelectronicallycontrolledunitinjectorsthatgiveslow
exhaustemissionswithgoodfueleconomyandahightorque.Forfurtherreductionof
NOxemissionstheenginesarealsoequippedwithanexhaustgasrecirculation,EGR,
systemdevelopedbyScania.Theenginecanbefittedwithmanyaccessoriessuchas
aircleaners,radiatorsandPTOsinordertosuitavarietyofinstallations.
Thisspecificationmayberevisedwithoutnotice.
Engine speed (rpm)
1500 rpm (50 Hz) 1800 rpm (60 Hz)
PRP PRP
Grosspower(kW) 438 483
Grosspower(kVA) 500 540
Specfuelconsumption.Fullload(g/kWh) 204 211
Specfuelconsumption.3/4load(g/kWh) 210 213
Specfuelconsumption.1/2load(g/kWh) 211 215
Heatrejectiontocoolant(kW) 198 219
PRP – Prime power:Forcontinuousoperationatvaryingload.Maxmeanloadfactorof70%ofra-tedpowerover24hofoperation.1hour/12hoursperiodofaccumulatedpeakoverloadto110%.
SCANIA POWER GENERATION ENGINEs
sE 151 87 södertälje, swedenTelephone +46 8 553 810 00Telefax +46 8 553 829 [email protected]
DC16 071A. 438-483 kW (500-540 kVA)EU stage IIIA
Edit
ion
03
© s
can
ia C
V A
B, s
E-15
1 87
sö
der
tälje
, sw
eden
Engine description
Noofcylinders 90ºV8
Workingprinciple 4-stroke
Firingorder 1-5-4-2-6-3-7-8
Displacement 16.4litres
Borexstroke 130x154mm
Compressionratio 16.7:1
Weight 1340kg(excloilandcoolant)
Pistonspeedat1500rpm 7.7m/s
Pistonspeedat1800rpm 9.24m/s
Camshaft Highpositionalloysteel
Pistons Steelpistons
Connectionrods I-sectionpressforgingsofalloysteel
Crankshaft Alloysteelwithhardenedandpolishedbearingsurfaces
Oilcapacity 35-45dm3
Electricalsystem 1-pole24V
1:70
901:
7092
1315
560 651
843
445
All dimensions in mm