DAY13 CHAPTER 16 GARAGES. DETACHED GARAGE. MUST HAVE AT LEAST 1 GFCI RECEPTACLE, 1 WALL CONTROLLED LIGHT AND 1 SWITCH CONTROLLED EXTERIOR LIGHT. RECEPTACLES IN A GARAGE REQUIRED TO HAVE GFCI PROTECTION 210.8(A)(2). Outdoor Wiring Codes - PowerPoint PPT Presentation
Transcript of DAY13 CHAPTER 16 GARAGES
DAY13 CHAPTER 16 GARAGES
DETACHED GARAGE
MUST HAVE AT LEAST 1 GFCI RECEPTACLE, 1 WALL CONTROLLEDLIGHT AND 1 SWITCH CONTROLLED EXTERIOR LIGHT.
RECEPTACLES IN A GARAGE REQUIRED TO HAVE GFCI PROTECTION 210.8(A)(2)
Outdoor Wiring Codes-Receptacles accessible from grade required at front and rear of dwelling, max 6 1/2ft above grade-Receptacle required for balconies with interior access and >20 sq ft-Receptacles in damp or wet locations required to be listed weather-resistant type-Outdoor damp location receptacle (e.g. covered deck) require weatherproof cover-Wet location 15A or 20A receptacles require in-use covers
UF NONMETALLIC SHEATHED CABLE
BACKUP POWER SUPPLY SYSTEM
AUTOMATIC GENERATORTRANSFER SWITCH