Flame Safeguard
Davies Is Your Authorized Fireye & Honeywell Burner Management Controls Distributor
Honeywell RM7800 Series Relay Modules
Fireye M Series II Chassis
Sub-bases Purge Cards Flame Amplifiers Keyboard Display Modules Communications Controls
Programmer Modules Reset Switches Expansion Modules Infrared Scanners UV & Vacuum Tubes
We carry a full line of Burner & Boiler Controls & related Flame Safeguard Products including:
A190 31/01/14
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Microprocessor-based integrated flame switch for detecting a flame using rectification, ultraviolet (UV) or infrared (IR) source
Three LEDs to indicate power, flame and alarm Access for external electrical voltage checks Non-volatile memory Shutter drive output Honeywell RM7800 Series
Flame Safeguard - 7800 Series Relay Modules
Flame Switch
Microprocessor-based integrated primary burner control for automatically fired gas, oil or combination fuel single burner applications
Five LEDs provide sequence information Interchangeable plug-in flame amplifiers Nonvolatile memory retains history files and sequencing status after
power loss Selectable relight or lockout on loss of flame Honeywell RM 7800 Series
On-Off Primary Control
Microprocessor-based integrated primary burner control for automatically fired gas, oil or combination fuel single burner applications
Five LEDs provide sequence information Interchangeable plug-in flame amplifiers Nonvolatile memory retains history files and sequencing status after
power loss Selectable relight or lockout on loss of flame Airflow switch check Honeywell RM7800 Series
On-Off Primary Control with Purge
A191 04/29/05
Contact Davies Experts For Details & Proper Application
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Microprocessor-based integrated primary burner control for automatically fired gas, oil or combination fuel single burner applications
Functions include automatic burner sequencing, flame supervision, system status indications, system or self-diagnostics and troubleshooting
Access for external electrical voltage checks Five LEDs provide sequence information Five function Run/Test switch Interchangeable plug-in flame amplifiers Nonvolatile memory retains history files and sequencing status after
power loss Selectable AirFlow switch check Honeywell RM7800 Series
Flame Safeguard - 7800 Series Relay Modules
Programmer
Microprocessor-based integrated primary burner control with pilot hold function for industrial semi-automatically fired gas, oil, coal or combination fuel single burner applications
C alarms only on safety shutdown and requires ST7800C purge timer Access for external electrical voltage checks Five LEDs provide sequence information Five function Run/Test switch Interchangeable plug-in flame amplifiers Local or remote annunciation of operation and fault information Nonvolatile memory retains history files and sequencing status after
power loss Pilot valve hold function requires plug-in flame signal amplifier Honeywell RM7800 Series
Programmer - Manual Start Industrial
Microprocessor-based integrated primary burner control for automatically fired gas, oil or combination fuel single burner applications
Functions include automatic burner sequencing, flame supervision, system status indications, system or self-diagnostics and troubleshooting
Access for external electrical voltage checks Application flexibility and communication interface capability Five LEDs provide sequence information Five function Run/Test switch Interchangeable plug-in flame amplifiers Nonvolatile memory retains history files and sequencing status after
power loss Selectable AirFlow check Honeywell RM7800 Series
Programmers with Annunciator
A192
Contact Davies Experts For Details & Proper Application
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Flame Safeguard - 7800 Series Required Components
Support remote mounting of S7800 keyboard display module, personal computer communications interface and remote reset
Use with remotely mounted S7800 keyboard display module Installs directly on front of 7800 series relay modules Honeywell S7800 Series
Data ControlBus™ Module
For select 7800 series relay modules Honeywell S7800 Series
Keyboard Display Module
Microprocessor-based expanded Annunciator to support the 7800 series relay modules for first-out annunciation, sequencing, system or self-diagnostics and troubleshooting
Twenty-six status LEDs Front panel LED array-arranged to indicate flow of line-voltage
through string of limits, controls and interlocks Selectable current and first-out LED array display status Twenty-one monitored contact points Access for external electrical voltage points Honeywell S7800 Series
Annunciator - First Out Expanded
A193
Contact Davies Experts For Details & Proper Application
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Burner, panel or wall mount subbases for relay modules or expanded Annunciator Makes electrical connections through bifurcated contacts Provides terminals for field wiring Twenty-two terminals Honeywell Q7800 Series
Terminal Universal Wiring Subbases
Flame Safeguard - 7800 Series Required Components
Provides the prepurge timing for select 7800 series relay modules Honeywell ST7800 Series
Plug In Purge Timers
Serves as link between remote pushbutton and relay module Reset button can be installed up to 1000' away Installs directly on front of 7800 series relay modules Honeywell S7800 Series
Remote Reset Module
A194
Panel Mount
Burner/Wall Mount
Contact Davies Experts For Details & Proper Application
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Flame Safeguard - 7800 Series Part & Accessories
7800 Series - Parts & Accessories Description Application Brand Part Number
Carrying Case For S7800 Display Honeywell 206311
ControlBus™ Module 3-Wire Electrical Connector For S7800 Display Honeywell 203541
Display Extension Cable - 60 inches For S7800 Display Honeywell 221818A
Dust Cover For 7800 Relay Modules Honeywell 221729A
Nema 1 Cover Assembly For Mounting S7800 Display Honeywell 204718B
Nema 4 Cover Assembly with Reset Button For Mounting S7800 Display Honeywell 204718C
Plug-in Power Supply (13 Vdc) For Remote Mounting S7800 Display Honeywell 203968A
Remote Mounting Bracket For S7800 Display Honeywell 203765
Solid State Ignition Transformer For use only in interrupted ignition applications and used
with C7027, C7035 or C7044 Minipeeper Ultraviolet flame Detectors
Honeywell Q624A1014
Terminal Slot Cover For Q7800 Honeywell 221779
A195
203968A
204718B
204718C
221729A
221818A Q624A1014
203541
Contact Davies Experts For Details & Proper Application
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Flame Amplifiers - 7800 Series Required Components
Solid State plug-in amplifiers that respond to flame detector inputs to indicate the presence of flame when used with 7800 series relay modules
Flame signal strength ranges from 0.0 to 5.0 Vdc Plug into 7800 relay module through printed circuit board edge
connector keyed for proper orientation Flame signal test jacks to measure amplifier flame signal voltage Color-coded label identifies flame detection type Honeywell R7800 Series
Flame Signal Amplifiers
Type Color Flame Failure Response Time
Self Checking Description Brand Part Number
Infrared Red 2.0 sec or 3.0 sec None Use with Flame Sensor: Gas, Oil, Coal: Infrared (lead sulfide) C7015
Honeywell R7848A1008
Infrared Red 2.0 sec or 3.0 sec Ampli-check Use with Flame Sensor: Gas, Oil, Coal: Infrared (lead sulfide) C7015
Honeywell R7848B1006
Rectification Green 0.8 sec or 1.0 sec None Use with Flame Sensor: Gas: Rectifying Flame Rods C7004, C7005, C7007, C7008,
C7009, Q179
Honeywell R7847A1025
Rectification Green 2.0 sec or 3.0 sec None Use with Flame Sensor: Gas, Oil, Coal: Ultraviolet Flame Sensor C7012A,C or
Gas: Rectifying Flame Rods C7004, C7005, C7007, C7008, C7009, Q179
Honeywell R7847A1033
Rectification Green 2.0 sec or 3.0 sec Dynamic Self-Check
Use with Flame Sensor: Gas, Oil, Coal: Ultraviolet Flame Sensor C7012E,F
Honeywell R7847C1005
Ultraviolet Purple 0.8 sec or 1.0 sec None Use with Flame Sensor: Gas, Oil: Minipeeper C7027A, C7035A, C7044
Honeywell R7849A1015
Ultraviolet Purple 2.0 sec or 3.0 sec None Use with Flame Sensor: Gas, Oil: Minipeeper C7027A, C7035A, C7044
Honeywell R7849A1023
Ultraviolet Purple 2.0 sec or 3.0 sec Ampli-check Use with Flame Sensor: Gas, Oil: Minipeeper C7027A, C7035A, C7044
Honeywell R7849B1021
Ultraviolet Blue 2.0 sec or 3.0 sec Dynamic Self-Check
Use with Flame Sensor: Gas, Oil, Coal: Adjustable Sensitivity Ultraviolet Flame
Sensor C7076
Honeywell R7886A1001
A196
Contact Davies Experts For Details & Proper Application
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
A196-1 04/29/05
Flame Safeguard - ControLinks™ - 7999 Series
Simultaneously controls up to four actuators When used with the ML7999 Universal parallel positioning actuator,
it represents a value added replacement of mechanical cam and linkage assembly controlling the relationship between fuel, airflow and flue gas recirculation (if used) on a power burner.
Power Input: 100 to 120 Vac (+10/-15%), 50/60Hz (±10%) Maximum Power Consumption: 10VA With one communications port the R7999 provides communications
capabilities similar to those found in the 7800 series controls Required Components: R7999 fuel air controller, Q7999 wiring
subbase, ML7999 universal parallel positioning actuator & ZM7999 software configuration tool
Honeywell R7999A series
ControLinks™ Fuel Air Control System - Fuel Air Controller
Provides 100lb-in torque, pulse-width-modulating (PWM) control of combustion air dampers, butterfly has valves, oil modulation valves and flue gas recirculation systems.
Must be used with the R7999 Fuel Air Controller Password protected with an eight digit hexadecimal identifications
signal Couples directly to a 1/2" shaft with no additional parts required Power Input: 100 to 240Vac +10/-15%, 50/60Hz Maximum Power Consumption: 15VA Enclosure: NEMA2/IP50 Honeywell ML7999A series
ControLinks™ Fuel Air Control System - Universal Parallel-Positioning Actuator - 7999 System Required Component
Contact Davies Experts For Details & Proper Application
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Flame Amplifiers - BC7000/R4140 Amplifiers
Solid state plug-in amplifiers respond to flame detector signal and indicate presence of flame Use with BC7000; R4075C,D,E; R4138C,D flame safeguard controls and appropriate flame detector and FSP5075A1,
FSP5075A3 flame amplifier modules Honeywell R7200 Series
Flame Amplifiers
Solid state, plug-in units allow use of rectification flame detection Use with R4795A,D flame safeguard primary controls and appropri-
ate flame detector Honeywell R7200 Series
Flame Safeguard Amplifiers
A197
R7247C1001 R7249A1003
R7289A1004
Contact Davies Experts For Details & Proper Application
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Flame Detectors - Infrared Flame Sensors
C7015A combination mount and 104662B and D plug-in lead sulfide cell senses infrared radiation from gas, oil, coal or dual-fuel flames
Used for combination or dual-fuel applications Detects pilot and main flame Mounts quickly and easily on a standard 3/4" sighting pipe Works where flame rod or rectifying photocell mounts are difficult to apply Includes 110634A bushing with magnifying lens and 105134-00021 orifice Uses photoconductive lead sulfide cells 104662B and D Honeywell C7000 Series
Infrared (Lead Sulfide) Flame Detector
Solid state electronic flame detectors for use with Honeywell flame safeguard controls and amplifiers
Sense ultraviolet radiation produced by combustion of gas, oil, coal or other fuels
Replace C70123 vacuum tube models Mount horizontally, vertically or at any angle in between Provide quick electrical hookup with threaded conduit fitting and
color coded wires Reduced nuisance shutdowns by wiring two in parallel Honeywell C7000 Series
Solid State Purple Peeper™ Ultraviolet Flame Detector
Minipeeper™ Ultraviolet Flame Detector
A198
C7027A1023/1031
C7027A1049
Compact flame detector for use with flame safeguard controls with ultraviolet amplifiers
Applications include coal, gas and oil fired burners Use on Honeywell flame safeguard primary safety controls and
burners requiring ultraviolet flame detection Mounts on a 1/2" sighting pipe by using an integral collar Can be wired in parallel for difficult sighting applications Seals against pressures as high as 5 psi when correctly installed Allows for blast tube mounting due to compact size Vibration 0.5 G max Electrical Connections: 2 NEC Class 1 leadwires Used With Flame Amplifiers:
R7249A, B, R7849A ,B ,R7749B, R7259, R7290 Honeywell C7027A Series
07/12/12
Contact Davies Experts For Details & Proper Application
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Compact flame detector for use with flame safeguard controls with ultraviolet amplifiers
Use on Honeywell flame safeguard primary safety controls and burners requiring ultraviolet flame
Mounts on a 1/2 sighting pipe by using an integral collar Protect the sensing tube with a shield Wires in parallel for difficult sighting applications Seals against pressures as high as 5 psi when correctly installed Field replaceable ultraviolet sensing tube Honeywell C7000 Series
Minipeeper™ Ultraviolet Flame Detector with Shield
Flame Detectors - Infrared Flame Sensor
Flame Detector Parts - 7800 Series
Description Application Brand Part Number
1/2" Internal to 1/2" External Adapter For C7015 Honeywell 133711
Ant-Vibration Mount For C7012, C7024 or C7061 Honeywell 123539
Bulk Pack - 20 psi Window For C7012E, F; C7024; C7061 Honeywell 114372
Kanthal Flame Rod - 18" For C7007A, C7011A Honeywell 102709B
Kanthal Flame Rod - 24" For C7008 Honeywell 105478D
Kanthal Flame Rod - 48" For C7007A, C7011A Honeywell 102709E
Lead Sulphide Cell, Medium Sensitivity For C7015 Honeywell 104662B
Lead Sulphide Cell, High Sensitivity For C7015 Honeywell 104662D
Swivel Mount For C7012, C7015, C7024, C7027, C7035, C7061, C7076 Honeywell 118367A
UV Power Tube (-40 to 250F) For C7035, C7061 Honeywell 129464N
UV Sensing Tube For C7012, C7024 Honeywell 113228
Vacuum Tube For C7012 Honeywell 113236
A199
104662B 104662D 113228 114372 129464N 133711
102709B 102709E 105478D
Contact Davies Experts For Details & Proper Application
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Flame Safeguard - Network Interface - Data Acquisition
A200
Allows remote monitoring and diagnostics of the BCS7700 or 7800 series relay modules
Provides local and remote annunciation of 7800 series and BCS7700 faults
Up to six ControlBus™ modules per network interface unit Modular construction, NEMA 1 rated enclosure
Network Interface ControlBus™ Modules
Description PC Requirements Brand Part Number
Network Interface ControlBus™ Module for use with RM7800
series
486 IBM™ compatible personal computer and ZM7850A
combustion system manager Honeywell QS7800A1001
Allows remote monitoring and diagnostics of the BCS7700 or 7800 series with an IBM™ compatible personal computer
Connects with GCS7700s or 7800 series systems Auto-dialout on BCS7700 or 7800 series faults up to three telephone
numbers Access control, password protection Dialout override for service alarms Internal software clock for date and time stamping of faults Light emitting diode (LED) status indication Modular construction. On-line data logging Personal computer interface; user friendly and menu driven
Network Interface Unit
Weight PC Requirements Brand Part Number
4 lbs, 10 oz. 2.l kg
486 DX2 66 MHz IBM™ compatible. 16 MB memory, 50 MB available hard disk space, 2X CD-ROM drive, Super VGA color
monitor, 3.5" diskette drive, serial port for modem, mouse or touch screen, parallel port for printer, printer, keyboard
Honeywell Q7700A1014
Electrical Ratings
120 Vac
Description Brand Part Number
ControlBus™ Module 3-Wire Electrical Connector
Honeywell 203541
Network Interface Parts
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Flame Safeguard - Primary Controls
A201
Provides solid state, electronic flame safeguard protection for industrial and commercial single or dual fuel burners
Uses rectification principle of electronic flame detection Relights once after flame failure in attempt to re-establish pilot before
lockout. Safe-start check prevents start-up if flame-simulating failure occurs in flame detector circuit
Includes built-in protection against ignition crossover in flame rods and SPDT alarm contacts
Solid state circuitry Mounts and removes easily through use of captive mounting screws Mounting base is made of strong thermoplastic
RA890F Protectorelay™ Primary Control - Rectification
Electrical Rating Flame Failure Response Time
Safety Switch Timing
Description Brand Part Number
120 Vac 0.8 sec 15 sec Rectification, with alarm contacts Honeywell RA890F1270
120 Vac 3.0 sec 15 sec Rectification, with alarm contacts Honeywell RA890F1288
120 Vac 3.0 sec 30 sec Rectification, with alarm contacts Honeywell RA890F1346
240 Vac 3.0 sec 15 sec Rectification, with alarm contacts Honeywell RA890F1387
Prepurge timer for R4795 Control Systems
Provides solid state, electronic flame safeguard protection for com-mercial and industrial single or dual fuel burners
Use with rectification or ultraviolet type flame detectors depending on the interchangeable, plug-in amplifier being used
Recycle once after flame failure in attempt to re-establish pilot before lockout
Include manual push-to-reset safety switch in a dust-resistant enclosure
Includes SPDT alarm contacts
Primary Control
Connections Description Brand Part Number
Alarm contacts: male quick connect terminals
120V 50/60 HZ less Amplifier and Prepurge
Timer Honeywell R4795A1016
Prepurge Timer
Purging Time Brand Part Number
Honeywell ST71A1000 7 sec
30 sec Honeywell ST71A1018
60 sec Honeywell ST71A1026
90 sec Honeywell ST71A1034
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Flame Safeguard - Primary Controls
A202
Used with RA890 and R4795 controls Serves as junction box for connecting to external circuits Contains terminal blocks with coded terminals and screws
Provides solid state, electronic flame safeguard protection for industrial and commercial single or dual fuel burners
Designed for interrupted ignition with intermittent pilot on gas burners, and interrupted or intermittent ignition on oil burners
Use with a C7027, C7035 or C7044 Minipeeper™ ultraviolet flame detector for flame sensing
Relights once after flame failure in attempt to re-establish pilot before lockout
Solid state circuitry, eliminates warm-up and increases resistance to vibration
RA890G Protectorelay™ Primary Control - Ultraviolet
Electrical Rating Flame Failure Response Time
Safety Switch Timing
Description Brand Part Number
120 Vac 0.8 sec 15 sec Ultraviolet, with SPDT alarm contacts Honeywell RA890G1229
120 Vac 3.0 sec 15 sec Ultraviolet, with SPDT alarm contacts Honeywell RA890G1260
Wiring Mount Base
Description Brand Part Number
Wire Mounting Base for RA890 & R4795 controls Honeywell Q270A1024
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Intelligent microcomputer-based integrated control system for automatically fired commercial and industrial single burner applications Requires a PM720G,L or M program module
Provides higher levels of protection than conventional flame safeguard programmers to reduce service, maintenance, downtime and energy costs
Referred to as the Blue Chip because of its computer "chip" technology and its distinctive blue color Directly replaces R4150 and R4140 in most applications: mounts directly on the same Q520A subbase. Sequences
burner motor, firing rate motor (PM720G and L models only), ignition, pilot valve and main fuel valve(s). Safety shutdown on flame failure (lockout). Ten second pilot flame establishing period. Flame failure response time: 2-4 seconds. Lockout switch timing: less than 1 second
Features Dynamic Self-Check Logic - Provides Safety Improvement A major breakthrough in safety through advanced microcomputer technology has allowed the extension of the original Honeywell Dynamic Self Check/Max Safety concept (formerly restricted to the flame detection circuit) to the basic program logic system - Dynamic Self Check Logic is a comprehensive family of unique safety provi-sions that continuously monitors the total system performance to provide the highest degree of safety available Annunciation and Self Diagnostics - Cut Service Costs With "Plug-Instantly" burner system startup, control, troubleshooting and repair have never been easier. Integral first-out annunciation and self-diagnostic functions reduce service costs and minimize the inconvenience and cost associated with downtime. These important new features are called "Plug-Instant" , because they are a standard provision of the BC7000 system - no additional hardware need to be purchased or installed or maintained Energy Saving Innovations - Reduce Fuel Consumption Unnecessary purge-related heat losses are minimized by innovative BC7000 system program logic provisions. Microcomputer intelligence is employed to reduce fuel consumption by optimizing the pre-purge and terminating wasteful blower operation when the system encounters an inoperative field interlock. This condition can cause con-ventional sequences to permanently stall in an unproductive purge Universal System Chassis - Minimizes Inventory Investment Now, through the flexibility of microcomputer technology, a single control chassis can be universally applied to perform any standard burner program. Solid state program modules plug in to implement the required burner se-quence of operation, timings and desired features. The universal BC7000 system chassis allows you to cover the full range of applications, supports, standardization and minimizes inventory investment
"Blue Chip" Microcomputer Burner Control System
Flame Safeguard - Programmers
Description Brand Part Number
Use with PM720G,L or M program module, R7247, R7248, R7249 or R7476 amplifier and matching rectification, infrared, or ultraviolet flame detector. Mounts on Q520A mounting subbase
Honeywell BC7000L1000
A203
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Flame Safeguard - Programmer Controls
A204
Plug-in programming module designed to provide burner program sequence, timing and features for BC7000 universal system
Selectable AirFlow check Features: Pre-ignition running and low fire interlocks 5 Second early spark termination Interrupted Pilot 15 Second Postpurge Pre-ignition 60 Hz Frequency
Bag Assembly for Fireye to R4140 conversion
Programming Module
Description Flame Establishing Period
Brand Part Number Pilot Main
Program Module, LHL, Proven Low Fire PrePurge 40 sec 10 sec 10 sec Honeywell PM720G2005
Program Module, On-Off, Proven Low Fire 30 sec 90 sec 10 sec 10 sec Honeywell PM720M2002
PrePurge
Programmer Control Parts
Description Brand Part Number
Includes adapter, cover insert, 2 plugs and #8-32 screw Honeywell 4074BZU
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Designed as a replacement for the Fireye M1 Series "relight" controls Provides ignition and flame safeguard for heating or process light oil
or gas fired burners Programmer module should be selected based on the type of flame
failure response time Fireye M Series II
Amplifier module should be selected based on the type of flame failure response time
Fireye M Series II
Designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process burners that use gas and/or light oil fuels
In the event of ignition failure, or following a safety shutdown, the unit locks out, activating an alarm circuit. Reset is required
Controls incorporate a safety checking circuit that is operative on each start. If flame (real or simulated) is detected prior to start or during e purge, the fuel valves will not be energized, and the unit will lock out
Replaceable fuse Fireye M Series II
Flame Safeguard - M Series II
Chassis
Amplifiers
Programmer Modules
A205 31/01/14
Contact Davies Experts For Details & Proper Application
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
A compact, microprocessor based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process equipment firing any type of fuel
Designed to be backward compatible with existing M-Series controls Advantages are zero dependence on discrete components previously
used for timing functions Fireye Micro M Series
Flame Safeguard - Micro M Series
Chassis
Amplifier module should be selected based on the type of flame failure response time and type of flame scanner
Fireye Micro M Series
Amplifiers
Programmers are micro-controller based modules that control the sequence of operation and also interface with plug-in amplifiers
LED indicators on the programmer modules indicate the current operating status of the control and during a lockout condition displays the fault as a coded sequence
Fireye Micro M Series
Programmer Modules
The reset switch will force the Micro M to recycle if depressed and released during the purge or run period
Fireye Micro M Series
Reset Switch
A206 31/01/14
Contact Davies Experts For Details & Proper Application
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Amplifier module should be selected based on the type of flame failure response time and type of flame scanner
Fireye E Series
Provides the proper burner sequencing, ignition and flame monitoring protection on automatically ignited oil, gas and combination fuel burners
On a safety shutdown, the display module will advise the operator that the control is in "lockout" and indicate the cause as well as the position in the operating sequence that it occurred
Fireye E Series
Flame Safeguard - E Series
Chassis
Amplifiers
Provides both current and historical information pertaining to the operation of the control
This module is a 2 line by 16 character LCD with keypad Mounts directly onto the front face of the EP and EPD style programmers RJ style connector for connection to the EP and EPD style programmers Fireye E Series
The functional operation, flame failure response time, purge timings, firing rate motor circuit, trial for ignition timings, recycling function and display messages are determined by the programmer
Take note of the programming sequence chart for each programming module for the proper explanation of prepurge timings
Fireye E Series
Programmers
Display Modules - LCD
A207 31/01/14
Contact Davies Experts For Details & Proper Application
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
The E500 display module can be remotely mounted in the ED400 remote display housing in either of two ways; as a stand alone unit or flush mounted to a panel
The ED400 is a two piece rigid plastic assembly with mounting holes and comes with a right angle plug adapter for easy
Fireye E Series
Flame Safeguard - E Series
Remote Display Housing
Ribbon cable for connecting the E300 expansion module to any EB700 chassis
Fireye E Series
Provides an easy, efficient method to panel mount the ED510 display module.
Kit contains a mounting plate, gasket, two 8-32 x 1 1/4" mounting screws, and ED58-8 cable
Fireye E Series
Provides increased interlock supervision capability of the FLAME- MONITOR™ system. It connects to any EB700 chassis by means of a ribbon cable
The module does not interfere with the normal operation of the FLAME-MONITOR™ system, it expands the message and diagnostic capability
Provides operational information and reduces troubleshooting time by identifying the specific limit in the operating control circuit and running interlock circuit which caused the burner to shutdown or lockout
Fireye E Series
Expansion Module
Expansion Module Cable
Remote Display Mounting Kit
A208 31/01/14
Contact Davies Experts For Details & Proper Application
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Plug-in amplifier modules permit the selection of flame detection method
Meter test jacks on each amplifier module provides flame single readout with a DC voltmeter
Fireye D Series
Flame Safeguard - D Series / M Series (Old Style)
Amplifiers
Solid state programmer is a plug-in module A test switch permits the operator to stop the start-up programming
prior to energizing the main fuel valves, for test purposes Fireye D Series
Programmer Module
Designed for heating or automatically ignited process burners using light oil, gas or combination light oil/gas fuels (single or multiple burner installations)
Controls monitor pilot and main flames Fireye M Series (Old Style)
Chassis
A209 01/02/08
Contact Davies Experts For Details & Proper Application
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Replacement cell for Infrared scanners
Has rugged die cast housing that mounts on pipe with setscrew Vertical mounting of UV tube provides greater sensitivity UV tube is replaceable Scanner is non self-checking Fireye 45UV Series
Designed to detect low frequency IR signals from gas or oil flames Mounting collar is 1/2" NPT Fireye 48PT Series
Flame Safeguard - Cells, Tubes & Scanners
Cells
Scanners - Infrared
Scanners - Ultraviolet - Standard
Scanners - UV - Self-Check
A210
For continuously fired applications where recycling is infrequent or absent The self-checking circuit checks the electronics and the UV tube for
proper operation every six seconds during the firing period Suitable for fuel gases and oil Replaceable UV tube Mounting 1" NPT
Description Brand Part Number
UV Self-check scanner with 8 foot lead. Use w/P-Series Fireye 45UV5-1005
UV Self-check scanner with 8 foot lead. 1" NPT threads. 120 VAC shutter. Use w/EUVS4, 72DUVS4 or 72DUVS1T
Fireye 45UV5-1009
UV Self-check scanner with 8 foot lead. 1" NPT threads. Preferred Scanner
Fireye 45UV5-1000
45UV5-1009 45UV5-1000
31/01/14
Contact Davies Experts For Details & Proper Application
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433
Miniature non self-checking scanners used in applications where scanners to flame distance does not exceed 20"
Suitable for fuel gases and number 2 oil Non-replaceable tube 1/2" NPT mounting collar Fireye UV1A Series
Flame Safeguard - Cells, Tubes & Scanners
Scanners - UV - Miniature
Tubes - UV
Description Brand Part Number
For 45UV5 scanners Fireye 4-320-1
Replacement UV tubes
Tubes - Vacuum
Replacement UV tubes
A211
Description Brand Part Number
Vacuum tube, 12SN-GT for 26SJ5, 26RJ8, 26UJ5, 29RF5-1000 series, F18T3, 47FU9, 27VH6
Fireye 4-84
Vacuum tube, 12AX7, 26RJ8, 26SJ5 and 29RF5 Fireye 4-91
Vacuum tube, 12H6, 26SJ5, 26RJ8, 26UJ5, 29RP5-1000 series
Fireye 4-98
Vacuum tube 12SL7GT, 26RJ8, 26SJ5, 29F5-1000 series Fireye 4-100
Vacuum tube 12BH7A, 26RJ8, 26SJ5, 29RF5, all 5000 and 6000 series
Fireye 4-204
31/01/14
Contact Davies Experts For Details & Proper Application