SOMNOtouch™ NIBPLong-term Blood Pressure
Continuous, non-invasive blood pressure measurement without cuff
Long-term ECG
Oximetry
+ Long-term ECG + Oximetry
efficient, comfortable, innovative
• Systolic&DiastolicBloodPressure(inmmHg),beat-to-beat• Easyapplicationwithmaximumcomfortforthepatientsthankstomeasurementwithoutinflationofthecuff(PTT-based*,clinicallyvalidated**)
• Movement&bodyposition(forsleep/wakedetermination)***
• 3channelECG• ECGreport• StressreportbasedonHRV• Exporttodifferentfileformats(EDF,SCP,ASCII,etc.)
• FingerPulseOximetry• Oximetryreport• ThroughtheAUXconnection,FlowandSnoreisoptionallyavailable
Medizinische Geräte für Schlafdiagnostik und Therapie
Online signal check on tablet PC or mobile phone
All in One
Medical Devices for Sleep Diagnostics and Therapy
MobileCheckSendsascreenshotoftherecordingforasignalchecktoyourmobilephone-nomatterwhereyouare.Transfertimesandperiodscanbeprogrammedindividually.
22 channels6internal(Bodyposition,movement,SpO2,pulserate,plethysmography,patientmarker)2AUX-upto8channelsperexternalconnector(e.g.:3channelECG,flow, snore,bloodpressurecalibration)Data collection / Data transferDatatransferviaBluetooth,wirelessdatatransferinrealtime12bitsignalresolutionIndividuallyadjustablerecordingratefrom4/sto256/sData storageinternaldatastorage,512MBcapacityCharginganddatatransferviadockingstationSize and weight74x55x16mm,58g(incl.battery)Display highresolution,colortouchdisplay,resolution320x240pixelsPower supplyLi-Ion-battery(rechargeable),upto12hrs.recordingdurationAnalysis software DOMINO light
Datasheet SOMNOtouch™ NIBP *Gesche,H.,etal.,Continuousbloodpressuremeasurementbyusingthepulsetran-sittime.Europeanjournalofappliedphysiology,2011Bartsch,S.,etal.,Validationofcontinuousbloodpressuremeasurementsbypulsetransittime.DtschMedWochenschr,2010.135(48):p.2406-12
**Patentnumbers:DE102005014048.3-35,EP20060001181.4-1526,US11/364174US2006/0217616A1,7374542
***Dick,R.,etal.,AASMstandardsofpracticecompliantvalidation[...]Physiologicalmeasurement,2010.31(12):p.1623-33
SOMNOtouch NIBP
Data analysis and reportBlood pressure report
ECG report
Oximetry report•DisplayofthebloodOxygensaturationandthecorrelationbetweennocturnalSpO2andnocturnalbloodpressure
•Detectionofrespiratorybasedchangesofthebloodpressure(optional)
• StressreportbasedonHRV• Arrhythmiadetection
Actigraphy
BP
Wake
mmHg
Pulse[bpm
] PP[m
mHg]
Wake
Wake
Sleep
Sleep
Sleep
• Continuous24hourbloodpressureprofile• DetectionofDipper/Non-Dipper• DetectionofNBPF™(NocturnalBloodPressureFluctuations)asanindicatorforcardicstress
• Determinationofthesuperpositioneffectofthebloodpressure
• Clearsleep/wakeallocationbyactigraphy***
MAP
Pulse
Printed:Decem
ber2012,Rev.0,S
ubjecttochange(withoutnotice)