€¦ · Datasheet Documents Hookup Diagrams 3 `Celsius `Fahrenheit Kelvin °F =1.8 ×°C+32 ` `...

26
By: Mr Razavipanah By: Mr.Razavipanah 1

Transcript of €¦ · Datasheet Documents Hookup Diagrams 3 `Celsius `Fahrenheit Kelvin °F =1.8 ×°C+32 ` `...

By: Mr RazavipanahBy: Mr.Razavipanah

1

ww

w.C

ontr

olM

aker

s.ir

General ConceptsGeneral ConceptsPressure Measurement Temperature MeasurementTemperature Measurement Level Measurement lFlow Measurement

2

ww

w.C

ontr

olM

aker

s.ir

Temperature Measurementp◦ Temperature Units◦ Contact Methods

ThermocouplepRTDThermistorBi-metalFilled DevicesStem Glass

N M h d◦ Non-contact MethodsInfra red method

Th ll◦ Thermowell◦ Datasheet Documents◦ Hookup Diagrams

3

ww

w.C

ontr

olM

aker

s.ir

CelsiusCelsiusFahrenheitKelvin

328.1 +°×=° CFKelvinRankin

273+°=° CK460+°=° FRKR °×=° 8.1

4

ww

w.C

ontr

olM

aker

s.ir

5

ww

w.C

ontr

olM

aker

s.ir

Law of Intermediate Law of IntermediateLaw of IntermediateMetals

Law of Intermediate Temperatures

6

ww

w.C

ontr

olM

aker

s.ir

7

ww

w.C

ontr

olM

aker

s.ir

Tamb=25ºCV=6.5mVTprocess=?

T =25ºC V =1mVTamb=25 C Vamb=1mV6.5mV + 1mV = 7.5mV Tprocess=184ºC

8

ww

w.C

ontr

olM

aker

s.ir

PlatinumPlatinum◦ PT100◦ PT500PT500◦ PT1000CopperCopperNickel

9

ww

w.C

ontr

olM

aker

s.ir

10

ww

w.C

ontr

olM

aker

s.ir

2 wire2 wire3 wire

4 wire

11

ww

w.C

ontr

olM

aker

s.ir

12

ww

w.C

ontr

olM

aker

s.ir

A thermistor is a semiconductor deviceA thermistor is a semiconductor device formed from metal oxides. The principle of temperature measurement with a thermistortemperature measurement with a thermistoris that its resistance changes with temperature.temperature.

13

ww

w.C

ontr

olM

aker

s.ir

Thermistor types:Thermistor types:◦ NTC (Negative temperature coefficient)◦ PTC (Positive temperature coefficient)PTC (Positive temperature coefficient)

14

ww

w.C

ontr

olM

aker

s.ir

Advantages:S ll i F t V hi h iti it◦ Small size, Fast response, Very high sensitivity, Polarity insensitive

Disadvantages:Disadvantages:◦ Unstable, Non linear, Narrow span, Fragile, High

resistance, noise problemsresistance, noise problems

15

ww

w.C

ontr

olM

aker

s.ir

16

ww

w.C

ontr

olM

aker

s.ir

Class I: LiquidC ass qu dClass II: VaporClass III: GasClass III: GasClass IV: Mercury

17

ww

w.C

ontr

olM

aker

s.ir

Low cost Simplicity No recalibration requiredLow cost, Simplicity, No recalibration requiredLocalised measurement only, Isolated from other control and recording equipmentother control and recording equipment, Fragile

18

ww

w.C

ontr

olM

aker

s.ir

A+R+T=1NKTTV ε=)( )(

TN λ/14388=

Emissivity:ε

19eTemperaturT

Emissivity::ε

ww

w.C

ontr

olM

aker

s.ir

20

ww

w.C

ontr

olM

aker

s.ir

21

ww

w.C

ontr

olM

aker

s.ir

Removal or replacement of the sensing deviceRemoval or replacement of the sensing device without opening up the process tank or pipingpipingProtection of sensing elementIncreasing response timeIncreasing response time

22

ww

w.C

ontr

olM

aker

s.ir

Thermowell ThermowellThermowellconnection types:

Thermowellconstruction types:

23

ww

w.C

ontr

olM

aker

s.ir

24

ww

w.C

ontr

olM

aker

s.ir

25

ww

w.C

ontr

olM

aker

s.ir

h kh kThank youThank youyy

26

ww

w.C

ontr

olM

aker

s.ir