6
200/70MHz Bandwidth Selections, Two Input Channels 1GSa/s Maximum Sample Rate Maximum 5M/1M Memory Depth Per Channel 7” 800 x 480 Full Touch Panel Capacitive LCD Multi-Point Control, Landscape and Portrait Display Built-In 50,000/5,000 Counts DMM 30,000 Consecutive Waveform Records Logging Function, Replay Measurement Results Any Time Temperature Measurement and Logging Function Built-In Engineering Calculator, SMD Resistance Coding, Color Coding Info, and Attenuator Calculation Application Software Optional Differential Probe to Achieve Isolation Effect UN38.8 IEC62133 Built-in FlashMemory Li-polymer Battery ENGLISH 124-1951 124-0231 123-3546 123-3545 Datasheet Stock No. : Model : FEATURES IDS-320 IDS-307 IDS-220 IDS-207 Digital Storage Oscilloscope

Transcript of Datasheet Digital Storage Oscilloscope

Page 1: Datasheet Digital Storage Oscilloscope

200/70MHz Bandwidth Selections, Two Input Channels 1GSa/s Maximum Sample Rate

Maximum 5M/1M Memory Depth Per Channel

7” 800 x 480 Full Touch Panel Capacitive LCD Multi-Point Control,Landscape and Portrait Display

Built-In 50,000/5,000 Counts DMM

30,000 Consecutive Waveform Records Logging Function, ReplayMeasurement Results Any Time

Temperature Measurement and Logging Function

Built-In Engineering Calculator, SMD Resistance Coding, ColorCoding Info, and Attenuator Calculation Application Software

Optional Differential Probe to Achieve Isolation Effect

UN38.8 IEC62133Built-in

FlashMemoryLi-polymerBattery

ENGLISH

124-1951

124-0231

123-3546

123-3545

Datasheet

Stock No. : Model :

FEATURES

IDS-320

IDS-307

IDS-220

IDS-207

Digital Storage Oscilloscope

Page 2: Datasheet Digital Storage Oscilloscope

IDS-300/200 Series Rear Panel

200/70 MHZ Digital Storage Oscilloscope

The brand new portable 7” full touch panel capacitive LCD, featuring multi-point touch panel method which allows engineers

to move waveform position, adjust waveform size, and set trigger conditions easily, subverts the traditional handheld

instrument. With this unique feature, engineers can retrieve DUT's signals easily under the complex working environment.

Landscape or portrait measurement display not only clearly shows waveforms under full screen status but also combines

multi-functional measurement environment to achieve unimaginable measurement results.

Built-in, the second to none, the longest 5M sample memory depth helps engineers diagnose waveforms in great details.

The long memory depth can record detailed waveform data and help engineers reproduce the original waveforms while

engineers are conducting long observation or retrieving detailed transient signals. Any delicate changes of analog waveforms

can be clearly presented in front of engineers when they adjust time scale from long to short that leaves no measurement

problems unanswered.

Built-in 50,000 counts (IDS-300) or 5,000 counts (IDS-200) DMM helps engineers accurately measure DUT's electric

parameters including not only measurements of D.C. voltage, A.C. voltage, D.C. current, A.C. current, resistance and diode

polarity, but also temperature measurement and monitoring. The analysis of trend diagrams further completes test and

measurement. DMM can simultaneously work with oscilloscope to conduct multi-measurement tasks.

Normally, engineers wish to effectively record intermittent signals while retrieving a series of signals during a long period of

time. IDS-300/IDS-200's built-in 30,000 consecutive waveform records logging function not only records 30,000 waveform

records in a long period of time but also replays the recorded data that allows engineers to identify intermittent problems

occurred during the recorded time. Leave no problems unidentified.

Engineers need to isolate power and solve corresponding grounding issue while conducting circuit debugging. One of the

criteria engineers must overcome is to maintain system grounding and isolation safety in the strict test and measurement

environment such as no grounding system or no isolation. IDS-300/200 provide optional differential probe to effectively

assist engineers in solving isolation and grounding problems that elevates the efficiency and safety of test and measurement.

Engineers often need some calculation tool software to conduct circuit design and debugging analysis during the R&D

process. IDS-300/200 oscilloscopes, with the built-in standard engineering calculator, allow engineers to verify parameters

during the test and measurement process. While using unknown resistance, engineers can obtain resistance value via color

coding calculation software. If any attenuator was designed in the circuit, IDS-300/200 can also provide corresponding

attenuator model and attenuation value calculation.

IDS-200 Series IDS-300 Series

MODEL

Bandwidth

Sample Rate

Memory Length

DMM Count

Temperature Measurement

IDS-307

70MHz

1GSa/s

5M pts

50,000

IDS-320

200MHz

1GSa/s

5M pts

50,000

IDS-207

70MHz

1GSa/s

1M pts

5,000

IDS-220

200MHz

1GSa/s

1M pts

5,000

SELECTION GUIDE

Page 3: Datasheet Digital Storage Oscilloscope

B.

IDS-200/300 series oscilloscopes adopt full touch panel capacitive LCD.

can also usher users into

the full touch panel measurement era. With only one finger, users not

only can move waveform up and down but also the trigger line position.

Two-point touch panel is also applied. Engineers can use two fingers to

In the era of smart phone explosion, RS PRO

C.

IDS-200/300 series oscilloscopes allow portrait and landscape display.

Engineers have different requirements under different environments.

When field test and measurement is necessary engineers often need

portrait display to conduct measurement due to environment limitation

and the emphasis of integrated functions. Waveform measurement and

FULL TOUCH PANEL CAPACITIVE LCD

PORTRAIT/LANDSCAPE DISPLAY

adjust vertical voltage level and to enlarge or narrow time division scale.

The brand new touch panel and swift response renew your measurement

concept. Additionally, one finger drag menu selection allows users to

follow their intuition to locate required measurement functions, and to

save and retrieve diagrams and data anytime anywhere.

DMM can be simultaneously operated. When indoor test and

measurement is required engineers often need stable measurements

and large screen which is answered by landscape display. 7” full

measurement screen can also be applied as a stable desk-top oscilloscope.

A.

IDS-200/300 Series oscilloscopes, with two analog signal input channels, have standard advanced and economical models which come with 70MHz and 200MHz bandwidth. The maximum sample rate per channel is 1GSa/s

and memory depth is 5Mpts. Both series oscilloscopes are equipped with

50,000 counts DMM which can simultaneously measure and monitor A.C.

and D.C. voltage and current, and temperature. Trend diagrams in a long

period of time can also be drawn that allows engineers to effectively

monitor standard electric parameters while measuring basic

BRIEF ELABORATION

circuit signals. Engineers are aware of RS PRO oscilloscopes' thoughtful designs through diversified application software. Advanced DMM function and GO/NOGO template editing facilitate users in conducting advanced diversified measurement functions. Engineering calculator, attenuator calculation analysis, and resistance value calculation analysis help users apply auxiliary functions that demonstrate the concept of powerful and comprehensive technological integration.

Page 4: Datasheet Digital Storage Oscilloscope

Engineers or students often compile briefing material for work or class

requirements. The completeness and convenience of briefing often

determine users' performance. IDS-200/300 series oscilloscopes provide

very strong briefing material compilation function. Before compiling

briefing material, users can select different test and background

G.

Many component or system manufacturers require GO and NOGO

product analysis for quality control or production. IDS-200/300 series

oscilloscopes have the same GO/NOGO function as that of RS PRO

other oscilloscopes. This function establishes corresponding waveform

templates based on waveforms measured to conduct GO or NOGO

Traditional oscilloscopes can not meet users' requirements of conducting

integrated system circuit measurement. One extra DMM is often required

to work with traditional oscilloscopes to handle enormous test

requirements. IDS-200/300 series oscilloscopes integrate the functions

of oscilloscope and DMM to conduct simultaneous measurement. In the

analysis of system circuit waveforms, IDS-200/300 can also use DMM

to measure basic voltage and current of the peripheral components that

provides users with very powerful test integration.

GO/NOGO TEMPLATE EDITING

results calculation. Additionally, IDS-200/300 have template editing

function. Users not only can edit template freely according to test or

environment conditions but also set templates with different ceiling

and floor boundaries, making GO/NOGO function more diversified

and user-friendly.

conditions such as date, time and cursor. In addition, measurement

parameters can also be determined based upon different requirements.

This customer-made function not only shows the complete waveforms

but also provides peripheral parameters to become the key communication

bridge for work and class requirements.

F.

IDS-200/300 series oscilloscopes have built-in 30,000 waveform records

replay function. With this function, engineers can monitor circuit in a long

period of time. When 30,000 waveform records are completed history

records can be replayed repeatedly. Any intermittently appeared

abnormal waveforms can be identified by this function which provides

users with a very powerful search and debugging weapon.

E. 30,000 WAVEFORM RECORDS REPLAY FUNCTIOND.

BRIEFING MATERIAL COMPILATION

SIMULTANEOUS APPLICATION OF OSCILLOSCOPE AND DMM

Page 5: Datasheet Digital Storage Oscilloscope

K.

I.

L.

J.

H.

IDS-200/300 series oscilloscopes have built-in diversified application

software to provide users with very thoughtful auxiliary tools. In the

tedious circuit design process, engineering calculator software provides

mathematical calculation functions from basic to advanced allowing

engineers to thoroughly understand circuit response and parameter

IDS-200/300 series oscilloscopes can record screen images and preview

images. In many complex test and measurement environments, when

engineers can not observe images from his or her computer immediately

after images were stored the image preview function allows users to

make sure file is correct right away. Pre-observation operation is also

very convenient to users.

Once engineers finished waveform measurement and report compilation,

IDS-200/300 series oscilloscopes can be used as USB storage

component to retrieve and store files. Briefing speaking, users can use

USB connecting cable to connect IDS 200/300 with the PC or handheld

device to retrieve any required files for follow-up actions. Today, smart

phone is ubiquitous, measurement results can be transmitted via smart

phone that saves a lot of troubles.

In many strict test and measurement environments, system power

isolation and grounding problem have become one of the key issues.

Bad isolation and grounding will have serious impact on circuit system

safety. Optional differential probe of IDS-200/300 series oscilloscopes

can achieve equivalent isolation results for measurement system and

there is no grounding problem. Under today's economic constraints,

using differential probe to achieve isolation result is one of the best

choices.

IDS-200/300 series oscilloscopes' built-in temperature measurement

and logging function allows users to conduct systematic temperature

measurement and logging for electric components and electric systems.

This function can collocate with different temperature measurement

probes. B,E,J,K,N,R,S,T thermal coupling measurement probes are also

supported to conduct Celsius and Fahrenheit scaled temperature

measurement. Users can also use trend plot editing to conduct

temperature monitoring in a long period of time. It is a simple and

convenient measurement tool for quality assurance and test departments.

TOOLS ELECTRICAL ENGINEERS OFTEN APPLIED

IMAGE STORAGE AND PREVIEW FUNCTION OPTIONAL DIFFERENTIAL PROBE

USED AS USB COMPONENT TEMPERATURE MEASUREMENT AND LOGGING FUNCTION

value. Resistance calculation software not only provides accurate

resistance value for different surface embedded resistance codes but

also color coding resistance value enquiry function. It is a very powerful

auxiliary tool for users from students to senior electrical engineers

Page 6: Datasheet Digital Storage Oscilloscope

Specifications subject to change without notice.

ORDERING INFORMATION

SPECIFICATIONS

VERTICAL

SIGNAL ACQUISITION

TRIGGER

HORIZONTAL

XY MODE

CURSOR ANDMEASUREMENT

TEMPERATURE MEASUREMENTMISCELLANEOUS

BATTERY

PROBE COMPENSATIONINTERFACE

DISPLAY

POWER ADAPTOROPTIONDIMENSIONS & WEIGHT

DMM

ChannelsInput ImpedanceMaximum InputInput Coupling

BandwidthRise TimeSensitivityAccuracyBandwidth LimitPolarityOffset Position Range

Realtime Sample Rate

Memory Depth

Acquisition Mode

Replay Wfms.

SourceTrigger modeTrigger typeTrigger HoldoffCouplingSensitivity

RangeRollPre-triggerPost-triggerAccuracy

Phase Shift

CursorsAuto-measurementAuto-counterAutoset

Multi-Language MenuOn-line HelpTime and Clock

Battery powerCharge timeOperation time

USBInternal Flash DiskTypeDisplay ResolutionDisplay DirectionBacklight ControlTouch Panel

Line VoltageDifferential Probe

Digit Level

DC Voltage

Input Impedance

DC Current RangeAccuracy

AC Voltage RangeAccuracy

AC Current RangeAccuracy

RESISTANCE Range

RangeResolution

AccuracyDiode TestTemperature(thermocouple)

ThermocoupleContinuity BeepFunctions

IDS-207 IDS-220IDS-307 IDS-3202 (BNC-Shield)1M 2%, 16.5pf approx.Ω

CAT II 300VRMSAC, DC, GND

DC~70MHz(-3dB) DC~200MHz (-3dB) DC~70MHz (-3dB) DC~200MHz (-3dB)<5ns <1.75ns <5ns <1.75ns2mV/div~10V/div (1-2-5 increments)±(3% x Readout + 0.1 div + 1mV)20MHz(-3dB)Normal, Invert2mV/div~50mV/div : ±0.4V; 100mV/div~500mV/div : ±4V; 1V/div~5V/div : ±40V; 10V/div : ±300V

1GSa/s

5Mpoints per ch 1Mpoints per ch

Average : 2~256 waveforms; Peak detect : 10ns; sin(x)/x or ET30,000 wfms.

Ch1 or Ch2Auto, Normal, Single, ForceEdge, Pulse Width, Video, Alternate10ns ~ 10sAC, DC, LFR, HFR, NRDC~25MHz : approx. 0.5div or 5mV; 25MHz~ 70/100/200MHz : approx. 1.5div or 15mV

5ns~100s/Div (1-2-5 increments)100ms/div ~ 100s/div10 div max.1,000 div max(depend on time base)±20ppm over any > 1ms time interval

±3° at 100KHz

Voltage difference between cursors( V), Time difference between cursors( T), frequency measure(1/ T)△ △ △

36 sets.6 digits. Range: 2Hz to rated bandwidth

Available Non-Available

AvailableAvailableAvailable

Li-polymer 6100mA/hr, 7.4V (Built-in)2.0 hour (75%)4.1 hour, depending on operating condition.2V, 1kHz, 50% Duty cycle

USB Device (Isolation)120MB

7 inch480 x 800 pixelsLandscape & PortraitManual adjustable, ECO modeCapacitive

AC 100V~240V, 47~63Hz, Power Consumption 40W; DC Output : 12V/3A, Double ShieldDual-channel, 40MHz, CAT II 600V240.2(W) x 136.0(H) x 59.7(D) mm; Approx. 1.5 Kg

5000 counts50,000 counts

RangeAccuracy

CAT II 600VRMS, CAT III 300VRMS50mV, 500mV, 5V, 50V, 500V, 1000V 6 rangesIDS-320/307:50mV,500mV,5V,50V,500V±(0.05%+5digits); IDS-220/207:50mV,500mV,5V,500V,1000V±(0.1%+5digits) 10MΩ50mA, 500mA, 10A 3 rangesIDS-320/307:50mA ~ 500mA, 2 range , ±(0.1% + 5 digits),10A±(0.5% + 1 digit)IDS-220/207:50mA~500mA, 10A 3 ranges, ±(0.5% + 1 digit)50mV, 500mV, 5V, 50V, 700V 5 ranges50mV, 500mV, 5V, 50V, 700V ±(1.5% + 15 digits) at 50Hz~1kH

50mA, 500mA, 10A 3 ranges50mA, 500mA, ±(1.5% + 15 digits) at 50Hz~1kHz; 10A ±(3% + 15 digits) at 50Hz~1kHz *Measurement range:>10mA

500 5K 50K 500K 5M 6 rangeΩ, Ω, Ω, Ω, Ω500 5K 50K 500K 0.3% + 3 digits); 5M 0.5% + 5 digits)Ω, Ω, Ω, Ω ( Ω ( *Measurement range:50 ~5MΩ Ω

Maximum forward voltage 1.5V, Open voltage 2.8V- ~ +50 C 1000 C0 1 C.B E J K, N, R, S, T, , , *Specifications do not include probe accuracy. Temperature specifications only apply to the GDS-320/310/307.< Ω15Auto Range, Max, Min, Hold, Trend plot

SPECIFICATIONS

200MHz, 2 Channels, Digital Oscilloscope 70MHz, 2 Channels, Digital Oscilloscope 200MHz, 2 Channels, Digital Oscilloscope

IDS-320 IDS-307 IDS-220 IDS-207 70MHz, 2 Channels, Digital Oscilloscope

ASSESSORIES

OPTIONAL ASSESSORIES

FREE DOWNLOADOpenWave 200 Software

GTP-150B-2GTP-250B-2

150MHz Probe, Suitable for IDS-307/207250MHz Probe, Suitable for IDS-320/220

Quick start guide x 1, User manual CD x 1 ,Power cord x 1

GTL-207 Multimeter Test Lead x 2

GSC-010 Soft Carrying CaseGSC-011 Soft Carrying BagGAP-001 AC-DC AdaptorGWS-001 Wrist Strap

GDP-040D 40MHz Dual-channel Differential Probe

GTL-253

GCL-001 Vertical Calibration CableGPF-700 Protective Films for 7” Touch Screen GTL-131 Test Clip, Suitable for GDP-040D

USB Cable, USB 2.0, A-mini B Type, 1400mm

user
螢光標示
user
刪劃線
user
插入號
IDS-320/307