Data Sheet
800 SERIESIndicating Temperature Controls and Thermometers
INDICATING TEMPERATURE CONTROLS AND THERMOMETERS
8 0 0 - B - 0 7
80
0 S
erie
s800 Series
featureS
• Simpleadjustmentandcontrol
• Ruggedconstructionfordemandingapplications
• Improveefficiencywithbest-in-classrepeatability
• Meetenvironmentrequirementswithenclosure
designoptions
• Matchprocessrequirementswithanassortmentof
availableranges
2 w w w . u e o n l i n e . c o m 8 0 0 - B - 0 7
800 Series
For applications that require a visual display of process temperatureandsetpoint,the800Seriesoffersahighlyreadablefourinchsetting/indication scale. It is available in two versions: a Lexan® enclosurefor enclosure type 1 or 4 applications (with option M300), and withLexan® window and epoxy-coated aluminum enclosure for Div. 1explosionproofapplications.Fortemperatureindicationonly,theT800thermometer incorporates the same performance and constructionfeaturesofthe800Series.
800Seriesmodelscontrolandindicatethetemperatureoffoodserviceappliances,ovens,packagingmachines,HVACequipment,andvarioustemperatureapplicationswithinprocessplants.
overview features
• Temperatureindicationand
controlswitching
• SingleordualSPDToutput
• Stainlesssteelbulb&capillary
• Simpletoadjustviaexternalknob
• ExplosionproofmodelsareUL
listed,cULcertified,andATEX
compliant
• OptionalRussian,Ukrainian,and
Chinese,flameprooforintrinsic
safetycompliance
• Optionalthermowellsandunion
connectorsavailable
Singlesetpointversion Explosionproofversion
Lexan®isaregisteredtrademarkofSABICInnovativePlasticsIPBV
80
0 S
eri
es
8 0 0 - B - 0 7 w w w . u e o n l i n e . c o m 3
8 0 0 S e r i e s
specificationsStorage temperature -65to160°F(-54to71°C)
ambient temperature limitS -40to160°F(-40to71°C);setpointtypicallyshiftslessthan1%ofrangefora50°F(28°C) ambienttemperaturechange
Set point repeatability ±1%ofadjustablerange
Shock Setpointrepeatsafter15G,10millisecondduration
Vibration Setpointrepeatsafter2.5G,5-500Hz
encloSure Types800,802:Lexan®blackfinish;clearLexan®faceplate TypesT800,820E,822E:Diecastaluminum,epoxycoatedenclosure,gasketed;Lexan®coverand faceplate
encloSure claSSification Types800,802,T800:Designedtomeetenclosuretype1requirements(enclosuretype4by specifyingoptionM300).Types820E,822E:Designedtomeetenclosuretype4X;ClassIDiv.1 productsmeetenclosuretype7;ClassII,Div.1productsmeetenclosuretype9.CertifiedtoIP66 requirements
indication accuracy ±1%ofadjustablerange
Switch output OneortwoSPDT;dualswitchmaybeseparatedupto100%ofrange;excepttype822Ewhere switch#2canbesetupto25%ofrangespanbelowswitch#1setpoint.Switchesmaybewired “normallyopen”or“normallyclosed.”NOTAPPLICABLETyPET800.
dual Switch adjuStment Type802:Dualswitchcontrolshaveseparateknob&temperaturepointersforeachswitchset point(standard);turninnergreenknobforsetting#1switch;outerblackknobforswitch#2. Type822Ecommonadjustmentsingleknobandpointerforsetpoint
electrical rating 15A125/250/480VACresistive.ElectricalswitcheshavelimitedDCcapabilitiesat24-30VDC, 2Aresistiveand1Ainductive.125VDC,0.5Aresistive,0.03Ainductive.Consultfactoryfor additionalinformation.DCratingsarenotlistedonnameplate.NOTAPPLICABLETyPET800.
weight Types800,802,T800:Approx.3lbs.,4oz.(1,47kg) Types820E,822E: Approx.7lbs(3,18kg)
electrical connection Types800,802:7/8”diameterknockoutonlefthandside;18AWGcolor-codedleadwires,approx. 9inchesexposedwithstrainrelief(optionM100addsterminalblockwiring). NOTAPPLICABLETyPET800. Type820E:two3/4”NPTE/Cwithterminalblock.Type822E:one3/4”NPTE/Cwithterminal block
bulb and capillary 6feet304stainlesssteel
temperature fill Model1BS:solventfilled;models2-8:non-toxicoilfilled
temperature deadband Typically1%ofrangeunderlaboratoryconditions(70°Fambientcirculatingbathatrateof1/2°F perminutechange)
4 w w w . u e o n l i n e . c o m 8 0 0 - B - 0 7
800 Series8
00
Se
rie
s
united StateS and canada800 & 802 modelsul listed, cul certifiedUL873,file#E10667;CSAC22.2No.24
820e & 822e models
ClassI,Division1and2,GroupsB,C&DClassII,Division1and2,GroupsE,F&GClassIIIClassI,Zone1,GroupIIB+H2T6EnclosureType4Xul listed, cul certifiedUL1203&50;CSANo.25&30-file#E43374
europe820e & 822e modelsateX directive (94/9/ec)II2GExdIICT6GbII2DExtbIIICT85°CDbIP66Tamb=-40°Cto+75°CULInternationalDEMKOA/S(N.B.#0539)Certificate#DEMKO09ATEX0815573XRev.2EN60079-0,60079-1,60079-31
low Voltage directive (lVd) (2006/95/ec)UECcomplianttoLVDProductsratedlowerthan50VACand75VDCareoutsideofthescopeoftheLVDTheLowVoltageDirectivedoesnotapplytoproductsforuseinhazardouslocations
ruSSia820e & 822e modelsRostechnadzorPermitandGOST-RCoC(optional – code m406)1ExdIICT6XTamb=-40°Cto+71°CNANIOCCVECertificationCenterCertificate#POCCUS.05.B04260OCTP51330.0,51330.1,51330.10&51330-14
ukraine820e & 822e modelsGosnadzorohrantrudaPermit(optional - code m404)1ExdIICT6XExiaIICT6GaTamb=-40°Cto+71°CCertificate#720byBE(TCCExEE)OCT12.2.007.0,22782.0,22782.6
china820e & 822e modelsCQSTCertified (optional - code m408)ExdIICT6DIPA21TA+85°CTamb=-40°Cto+75°CGB3836.1,3836.2&12476.1Certificate#CNEx09.2180X
approvals UEdeclarationsandthird-partyissuedAgencycertificationsareavailablefordownloadatwww.ueonline.com/prod_approval.
temperature model chart
Model Adjustable Set Point Range Max. Temp. Scale Div. Bulb Size
°F °C °F °C °F °C ODxLength
1BS* -180to120 -117.8to48.9 170 76.7 5 5 3/8x3-3/4””
2BS -125to350 -87.2to176.7 400 204.4 10 5 3/8x2-7/16”
3BS -125to500 -87.2to260 550 287.8 10 5 3/8x2-1/8”
4BS -40to120 -40to48.9 170 76.7 5 2 3/8x6-3/4”
5BS -40to180 -40to82.2 230 110 5 2 3/8x5”
6BS 0to250 -17.8to121.1 300 148.9 5 2 3/8x4-1/2”
7BS 0to400 -17.8to204.4 450 232.2 10 5 3/8x3”
8BS 50to650 10to343.3 700 371.1 10 10 3/8x3-1/4”
Standardcapillarylengthis6ft.,optionalcapillarylengthsandprotectionareavailable,consultUE.
*NOTAVAILABLETyPET800
Note:TypeT800isanindicatingthermometeronlyandassuchcarriesnoapprovallistings.
8 0 0 - B - 0 7 w w w . u e o n l i n e . c o m 5
8 0 0 S e r i e s
how to order
type temperature
Type800-Bulbandcapillary;oneSPDToutput;externalindication Type802-Bulbandcapillary;twoSPDToutputs;externalindication Type820E-Bulbandcapillary;oneSPDToutput;externalindication,explosionproof Type822E-Bulbandcapillary;twoSPDToutputs;externalindication,explosionproof TypeT800-Bulbandcapillary;thermometeronlywithexternalindication
optionS
Switch optionS* deScription
0140 Goldcontacts,1A125VACresistive.NOTAVAILABLETyPE800,820E,T8000500 Closedeadband,5A125/250VACresistive.NOTAVAILABLETyPET8001070 10A125VDCorVACresistive;deadbandandminimumsetpointmayincrease.NOTAVAILABLE TyPES802,820E,T8002000 20A125/250VACresistive.NOTAVAILABLETyPET800
other optionS
M007 Drilled7/8”electricalopeningonrightside.NOTAVAILABLETyPES820E,822EandT800M100 Terminalblockwiring.NOTAVAILABLETyPE820E,822E(standard)ANDT800M201 Factorysetoneswitch;specifyincreasingordecreasingtemperatureandsetpoint.NOTAVAILABLE TyPE802,822E,T800M202 Factorysettwoswitches;specifyincreasingordecreasingtemperatureandsetpoint.NOTAVAILABLE TyPE800,820E,T800M300 EnclosureType4construction;includeswatertightconduitfittingandgasketing.NOTAVAILABLE TyPES820E,822E(whichalreadymeetenclosuretype4X)M320 Tamperresistantcover.NOTAVAILABLETyPEST800M404 FlameproofcomplianceforUkraineperGosnadzorohrantrudastandards.NOTAVAILABLETyPES800, 802,T800M406 FlameproofcomplianceforRussiaperRostechnadzorpermit(RTN).NOTAVAILABLETyPES800,802, T800M408 FlameproofcomplianceforChinaperCQSTstandards.NOTAVAILABLETyPES800,802,T800M444 PaperIDtagM446 StainlesssteelIDtag&wireattachment;limitedto2linesof25characterseachmax.M550 Oxygenservicecleaning;alcoholcleaningtoremoveresiduefromtheprocessconnectionM900 Watertightconduitfitting;converts7/8”holeto1/2”NPTfitting.NOTAVAILABLETyPES820E, 822E,T800 *AllswitchoptionshavelimitedDCcapabilities.DCratingsarenotlistedonnameplate.Consultfactoryfordetails.
building a part number
Selectatype
Refertothe“Type”sectionbelow.
Determinetypenumberbasedonswitchoutput,enclosure,adjustmentandreference.
Fillinthetypeportionofyourpartnumberwiththecorrespondingnumber.
Selectamodel
Refertothe“ModelCharts.”
Determinemodelbasedonadjustablerange,deadbandandproofpressure.
Fillinthemodelportionofyourpartnumberwiththecorrespondingnumber.
Selectanoption
Refertothe“Options”section.
Determineoptionnumberbasedonswitchoutput,optionalmaterialsorotherproductenhancements.
Fillintheoptionportionofyourpartnumberwiththecorrespondingnumber.
Leave“option”portionblankifnooptionsareneeded.FORMULTIPLEOPTIONS:CallUnitedElectricControls.
6 w w w . u e o n l i n e . c o m 8 0 0 - B - 0 7
800 Series8
00
Se
rie
s
options for temperature models
union connectorS** Option Replacement Number Description BrassW027 SD6213-27 1⁄2”NPTw/3⁄4”bushingW045 SD6213-45 3⁄4”NPTW051 SD6213-51 1⁄2”NPT 304StainlessSteelW028 SD6213-28 1⁄2”NPTw/3⁄4”bushingW046 SD6213-46 3⁄4”NPTW050 SD6213-50 1⁄2”NPTthermowellS** For all bulb & capillary switches Brass W075 SD6225-75 1⁄2”NPTwith3⁄4”NPTadapterbushing,4”BTW191 SD6225-191 1⁄2”NPT,4”BTW118 SD6225-118 1⁄2”NPTwith3⁄4”NPTadapterbushing,7”BTW192 SD6225-192 1⁄2”NPT,7”BT 316StainlessSteelW076 SD6225-76 3⁄4”NPT,4.5”BT W193 SD6225-193 1⁄2”NPT,4.5”BT W119 SD6225-119 3⁄4”NPT,7.5”BT W177 SD6225-177 1⁄2”NPT,7.5”BT optional lengthS:Optionalcapillarylengthto50’maybeavailablein304st/st.ArmororTeflon®capillaryprotectionmaybeavailabletolengthslessthanorequaltocapillarylength.ConsultUEforadditionalinformationandavailability.
ConsultUEregardingrepeatabilityandambienteffectsoncapillarylengthsover30’
**Dimensionaldrawingsforunionconnectorsandthermowellsmaybefoundatwww.ueonline.com
8 0 0 - B - 0 7 w w w . u e o n l i n e . c o m 7
8 0 0 S e r i e s
dimensional drawings(Dimensionaldrawingsforallmodelsmaybefoundatwww.ueonline.com)
800 SeriesExternal Set Point Adjustment & Temperature Indication
Type 820 E Type 822 E
†TypeT800hasnosetpointindicatingpointer.
Dimension A
models inches mm
1BS 3-3/4 95.3
2BS 2-7/16 62.0
3BS 2-1/8 54.0
4BS 6-3/4 171.5
5BS 5 127.0
6BS 4-1/2 114.3
7BS 3 76.2
8BS 3-1/4 82.6
SET POINTINDICATING
POINTER (SWITCH #2)
REDSET POINT
INDICATINGPOINTER
(SWITCH #1)GREEN
SET POINTADJUSTMENT KNOBS
TEMPERATUREINDICATINGPOINTER. (BLACK)
Types 802
Types 800 & T800
CP012131500Besuretovisitwww.ueonline.comforthelatestinformation.
180DexterAvenue,P.O.Box9143Watertown,MA02471-9143USATelephone:617926-1000Fax:617926-2568www.ueonline.com
recommended practiceS and warningS
United Electric Controls Company recommends careful considerationof the following factors when specifying and installing UE pressureand temperature units. Before installing a unit, the Installationand Maintenance instructions provided with unit must be read andunderstood.
• Toavoiddamagingunit, proof pressure andmaximum temperaturelimitsstatedinliteratureandonnameplatesmustneverbeexceeded,evenby surges in the system.Operationof theunitup tomaximumpressure or temperature is acceptable on a limited basis (e.g.,start-up, testing) but continuous operationmustbe restricted to thedesignatedadjustablerange.Excessivecyclingatmaximumpressureortemperaturelimitscouldreducesensorlife.
• A back-up unit is necessary for applications where damage toa primary unit could endanger life, limb or property. A high orlow limit switch is necessary for applications where a dangerousrunawayconditioncouldresult.
• The adjustable range must be selected so that incorrect,inadvertentormalicioussettingatanyrangepointcannotresultinanunsafesystemcondition.
• Install unit where shock, vibration and ambient temperaturefluctuations will not damage unit or affect operation. Whenapplicable,orientunitsothatmoisturedoesnotentertheenclosurevia the electrical connection. When appropriate, this entry pointshouldbesealedtopreventmoistureentry.
• Unitmustnotbealteredormodifiedaftershipment.ConsultUEifmodificationisnecessary.
• Monitor operation to observe warning signs of possible damageto unit, such as drift in set point or faulty display. Check unitimmediately.
• Preventative maintenance and periodic testing is necessary forcritical applications where damage could endanger property orpersonnel.
• Electrical ratings stated in literature and on nameplate must notbe exceeded. Overload on a switch can cause damage, even onthefirstcycle. Wireunitaccordingtolocalandnationalelectricalcodes,usingwiresizerecommendedininstallationsheet.
• Donotmountunitinambienttemp.exceedingpublishedlimits.
limited warrantySeller warrants that the product hereby purchased is, upon delivery,free from defects in material and workmanship and that anysuch product which is found to be defective in such workmanshipor material will be repaired or replaced by Seller (Ex-works, Factory,Watertown, Massachusetts. INCOTERMS); provided, however, that thiswarranty applies only to equipment found to be so defective withina period of 24 months from the date of manufacture by the Seller.Seller shall not be obligated under this warranty for alleged defectswhich examination discloses are due to tampering, misuse, neglect,improper storage, and in any case where products are disassembledby anyone other than authorized Seller’s representatives. EXCEPT FORTHE LIMITED WARRANTy OF REPAIR AND REPLACEMENT STATEDABOVE, SELLER DISCLAIMS ALL WARRANTIES WHATSOEVER WITHRESPECTTOTHEPRODUCT,INCLUDINGALLIMPLIEDWARRANTIESOFMERCHANTABILITyORFITNESSFORANyPARTICULARPURPOSE.
limitation of Seller’S liabilitySELLER’S LIABILITy TO BUyER FOR ANy LOSS OR CLAIM, INCLUDINGLIABILITy INCURRED IN CONNECTION WITH (I) BREACH OF ANyWARRANTyWHATSOEVER,EXPRESSEDOR IMPLIED, (II)ABREACHOFCONTRACT, (III)ANEGLIGENTACTORACTS (ORNEGLIGENT FAILURETOACT)COMMITTEDBy SELLER,OR (IV)ANACT FORWHICHSTRICTLIABILITyWILLBE INPUTTEDTOSELLER, ISLIMITEDTOTHE“LIMITEDWARRANTy”OFREPAIRAND/ORREPLACEMENTASSOSTATEDINOURWARRANTyOFPRODUCT.INNOEVENTSHALLTHESELLERBELIABLEFOR ANy SPECIAL, INDIRECT, CONSEQUENTIAL OR OTHER DAMAGESOFALIKEGENERALNATURE,INCLUDING,WITHOUTLIMITATION,LOSSOFPROFITSORPRODUCTION,ORLOSSOREXPENSESOFANyNATUREINCURREDByTHEBUyERORANyTHIRDPARTy.
UE specifications subject to change without notice.
international officeS
CHINA UnitedElectricControls,Shanghai Office Room1011,10thFlr, HuaiHaiZhonghuaBuilding No.885,RenminRoad,LuwanDistrict Shanghai200010,P.R.China Phone:+8621-62558059 email:[email protected]
UnitedElectricControls,Beijing Office Room1006,JainhaoInternationalBldg. BlockD,No.116 Zizhuyuanlu,HaidianDistrict Beijing,China100089 Phone:+86-10-5893-0518 email:[email protected]
EUROPE UnitedElectricControls 05-806Komorow Kujawska5,Poland Phone:+48224994804 email:[email protected]
INDIA #402,AriesAvenue-1 UnitedColony,Sama Baroda(Gujarat),India390008 Phone:+91(-265)-2788654 email:[email protected]
ASIA-PACIFIC UnitedElectricControls,FarEast No.1-2-2,2ndFloor Jalan4/101C CherasBusinessCentre Batu5,JalanCheras 56100KualaLumpur,Malaysia Phone:603-9133-4122 email:[email protected]
RUSSIA&SCANDINAVIA UnitedElectricControls,Moscow Elninskayastr.,15-140 Moscow,121552,Russia Phone:+7(495)640-88-06 email:[email protected]
u.S. SaleS officeS
UnitedElectricControls 31OldStageRoad HamptonFalls,NH03844 Phone:617-899-1132 email:[email protected]
UnitedElectricControls 1022VineyardDrive Conyers,GA30013 Phone:770-335-9802 email:[email protected]
UnitedElectricControls 5829GrazingCourt Mason,OH45040 Phone:513-535-5486 email:[email protected]
UnitedElectricControls 102SalazarCourt Clayton,CA94517 Phone:925-408-5997 email:[email protected]
UnitedElectricControls 27SummitTerrace Sparta,NJ07871 Phone:973-271-2550 email:[email protected]
UnitedElectricControls 33018WeatherbyCourt Fulshear,Texas77441 Phone:832-457-6138 email:[email protected]
canada
68MosleyCrescent Brampton,Ontario CanadaL6y5C8 Phone:905-301-1274 FAX:905-455-5131