POST STACK DATA LOADING
First Create a Survey
Fig1 : OW Command Menu
In the OpenworksCommand Menu , Select
Data > Management > Seismic Data Manager
Fig2: Seismic Data Manager_3D Survey_General
In the Seismic Data Manager tab , Select 3D Survey
In 3D Survey Compute General and Grid Information
Fig3: Seismic Data Manager_3D Survey_Grid
Save the Survey ( Example Save as Miroli Survey)
-
8/10/2019 Data Load Bidyut
2/13
Post-Stack Data Loading Using Seismic Tools
Fig4: Using Seismic Tools
-
8/10/2019 Data Load Bidyut
3/13
Fig5: OW Command Menu
In the Openworks Command Menu , Select
Data > Management > Seismic Tools
Fig6: Seismic tools Command Menu
In the Seismic Tools Menu , Select
Seismic > Post Stack data loader > Input data:: Select SEGY and Select Parameters
Post stack Family R5000 window > Input Data > Select Disk > Analyze
(Before analyze check data attribute and domain type)
Fig7
SEGY Data Input tab will Open
-
8/10/2019 Data Load Bidyut
4/13
SEG-Y Data Input Window > Select Data Media Storage as Disk > Select Analyze tab
(Check Data Attribute, Domain, update from template etc)
Fig8
(SEGY analyzer window will open)
Fig9
In SEG-Y Analyzer Window select the Disk file name (File > Select > Select the .sgy file).
Select start bottom to start the Analyze ..........Remember It will take some time
Note: The data will shown in Disk File name area , then push the start bottom , it will take automatically the standard
default segy template in Template name area /other wise select the template name from interactive SEGY analyzer
window ( Interactive SEGY Analyzer window > Template > Select> Standard SEGY) and the start the Analyze Process
-
8/10/2019 Data Load Bidyut
5/13
Fig10
Fig:11
Fig:12
Fig:13
The Analyzing Job is complete now. Now to check the template whether it is correct or any scaling factor is required
for CDPX and CDPY value.
-
8/10/2019 Data Load Bidyut
6/13
Fig14
Go to the Interactive SEGY Analyzer window and Show EBCIDIC Text header like Iline, X line, Shot Point, CDP
X Coordinate, CDO Y Coordinate etc.
Compare the EBCIDIC text header and BINARY trace heard of selected data whether binary trace header are
correct or any changes is required in In-line, X-line, Shot Point, CDP X and CDP Y Coordinate Position. The
value of CDPX and CDPY may check carefully whether any scaling factor is required or not.
To shoe the Binary Trace Header :: Interactive SEGY Analyzer > Trace > Header view
Fig15
-
8/10/2019 Data Load Bidyut
7/13
Fig16
Now Check the Trace header information ( Mainly Shot point, X Cord, Y Cord, #D Line and 3D Trace :: marked in blue
portion of Trace header view ) with EBCDIC Header Information (Which information we already got by clicking
Interactive SEGY Analyzer tab).
Fig:15 Fig16
Comparison Result:
Byte Information of Inline, X Line, CDPX and CDP Y indicated in EBCIDIC Text header is not match with Trace
header view and also digit of CDPX and CDPY is also not correct.
Note the header information in trace header view is showing the information from automatic selected
Standard_SEGY format.So the template format is required modification according the original EBCIDIC data
information.
-
8/10/2019 Data Load Bidyut
8/13
SEGY Analyzer browse > Edit template :: This template is the default template named as Standard_SEGY
intially for which wrong trace header fig 16 was shown , therefore modification and also save after this is
required for this template. Later using this modified template we will again analyze the input seismic .sgy
data to check whether the prvious problem byte location value of x y is showing correctly after scaling
factor. If it is shows ok then it will (this modified saved template will be used during our input data loading.
the standard SEGY template will open
SeG y Analyzer window > Browse / Edit template
Fig 17: Browse the default template, which need modification
accordingly EBCIDIC header data and scaling factor for X and Y
Figure18: Corrected teamplate
named as miroli_bidyut2
-
8/10/2019 Data Load Bidyut
9/13
Then save the new template after modification
After save ----plz check whether template is change and correct binary header is given for this again the data analyze
and check the x y factor, if it is ok, then save, your template is rready to use for data load
-
8/10/2019 Data Load Bidyut
10/13
Display the correct header view ...with cheking of x y factor
-
8/10/2019 Data Load Bidyut
11/13
Save the format ................ and this format is apply in template name ------------- and again analyze and see the
differenvce
-
8/10/2019 Data Load Bidyut
12/13
-
8/10/2019 Data Load Bidyut