Data Center Industry Update
Fan Zhang
Huawei Data Center Integration Services
Uptime Institute Symposium: Middle East
Dubai Dec. 7th 2016
Trend #1--Data Center Is A Cloud Now
Edge
Edge
Edge
Edge
Core
Regional
Regional
Regional
Edge
Edge
Core
Strategic Resources
• Coverage
• Bandwidth
Core Competency
• Orchestration
(The coordination of all your Data Centers)
Uptime Institute Symposium: Middle East Dubai Dec 7th 2016
Management Flexibility TTMEnergy
Efficiency
Trend #2-- Management Getting to Be the Top Consideration
What to manage ?
• Operation Status (Warnings/ Automated
Recovery)
• Asset (CMDB)
• Capacity (Load Rate, Reservation …)
• Energy Efficiency
Availability
Efficiency
Management
Uptime Institute Symposium: Middle East Dubai Dec 7th 2016
Multi DCs
APP
/w App/IT/Network
IntegratedFacility Management
Proactive Actions
Business Driven
Management TTM
Edge
Edge
Edge
Edge
Core
Regional
Regional
Reginal
Edge
Edge
Core
Regional
Energy
EfficiencyFlexibility
Uptime Institute Symposium: Middle East Dubai Dec 7th 2016
Scalable Capacity Adaptable Power Density Upgradeable Availability
Management TTM
Trend #3-- Flexibility Becoming More And More Important
Phase 3
Phase 2Phase 1 TIER IV
TIER III
TIER II
Energy
EfficiencyFlexibility
Uptime Institute Symposium: Middle East Dubai Dec 7th 2016
HVDC(Huawei HVDC5000(30~360kW))
Modular UPS (Huawei UPS5000)
UPS UPS
UPS PANEL
Utility
IT Load
IT Load
IT Load
UPS PANELLV PANEL
UPS UPS
UPS PANEL
Utility
IT Load
IT Load
IT Load
UPS PANELLV PANEL
TIER III
TIER IV
TIER II
3kW/rack7kW/rack
TIER IV
TIER IV
TTMManagementEnergy
EfficiencyFlexibility
TIER II
TIER III
TIER III
Uptime Institute Symposium: Middle East Dubai Dec 7th 2016
> 2 years
Building DC
6~10 months
Warehouse DC
3~5 months
Container DC
3~4 months
All Modular,
Prefabricated DC
Management TTM
Trend #4-- TTM Is As Important As TCO
Energy
EfficiencyFlexibility
Uptime Institute Symposium: Middle East Dubai Dec 7th 2016
Management TTMEnergy
EfficiencyFlexibilityUptime Institute Symposium: Middle East Dubai Dec 7th 2016
Management TTM
Trend #5-- Better Energy Efficiency
For Internet Companies, these become
Acceptable
• Trying New Technologies
• Lower Availability / Reliability
• Less Control on Temperature / Humidity
• DC Location Far Away from Office
• Invasion on DCIM
For Operators
• SLA based Price Model
> 2.0
PUE < 1.2
Energy
EfficiencyFlexibilityUptime Institute Symposium: Middle East Dubai Dec 7th 2016
CCHPRotary Wheel Air Conditioning Overhead Heat Pipe Air Conditioner
Sea / Lake Water Cooling
Direct to Chip Liquid Cooling
Direct Ventilation Air Cooling In Rack Heat Pipe CoolingOutdoor system Indoor system
Cold source system
monitoring controlIndoor system
monitoring control
Water system
monitoring control
Main refrigerant gas pipe
Main refrigerant liquid pipe
Soft connection
pipe
System control
Management TTMEnergy
EfficiencyFlexibilityUptime Institute Symposium: Middle East Dubai Dec 7th 2016
Changes
Energy
Efficiency
DC Cloud
Intelligent
Management
FlexibilityTime to
Market
Uptime Institute Symposium: Middle East Dubai Dec 7th 2016
Copyright©2016 Huawei Technologies Co., Ltd. All Rights Reserved.
The information in this document may contain predictive statements including, without limitation, statements regarding the future financial
and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and
developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for
reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.
Uptime Institute Symposium: Middle East Dubai Dec 7th 2016