Data Center
CH1Elk Grove Village, IL
>
powerful/efficient/reliablesolutions
Committed to ultimate reliability, DFT’s philosophy is to design, build, operate and manage highly dependable and environmentally efficient data centers. Our goal is to maximize Power Usage Effectiveness ("PUE") in all aspects of data center operations. Dynamic electrical distribution and flexible floor plans provide optimal solutions for our tenants. DFT commissions proven technologies, such as rotary UPS and evaporative chilled water systems, in configurations that maximize utilization of the data center design and infrastructure. Our engineering track record and expertise enable us to shorten the duration of construction and minimize costs which directly benefit our clients.
PHILOSOPHY
Located in the western suburbs of Chicago, CH1 is one of the Midwest’s most sophisticated and efficient data centers. The facility is constructed in two phases of 18.2 MW of Critical Load each. Clients are able to lease one or multiple dedicated computer rooms each with independent redundancy and security. The property has multiple major fiber carriers on site and benefits from some of the country’s most competitive power rates. Customers requiring substantial office space can utilize the adjacent and exclusive 32,000 square foot office building.
OVERVIEW
DFT is a leading owner, developer, operator and manager of wholesale data centers. Our highly advanced and secure facilities power, cool, and protect the computer servers of numerous enterprise and technology companies. In conjunction with our operational expertise, we deliver uninterrupted service and ultimate reliability to our customers’ mission critical business applications.
ABOUTDUPONT FABROSTECHOLOGY(DFT)
>
Data Center CH1
>
Data Center CH1: Specifications
PROPERTY
BUILDING DESCRIPTION
Location: Elk Grove Village, ILAcreage: 22.8Building Size: 485,000 sq ftNearest Airport: O'Hare International Airport
Utility Power: 34.5 kVParking: 400+Number of Stories: 1Loading Docks: 4 Dock Bays
CRITICAL POWER
DATA CENTER AREA DESCRIPTION
Total Megawatts: 36.4Redundancy: N+2, Each Phase, plus additional Swing UPS which offers additional redundancy to either electrical system
Raised Floor Area: 121,000 sq ft (Phase I), 109,666 sq ft (Phase II)Number of Computer Rooms: 16 (Phase I), 15 (Phase II)Raised Floor Height: 42" under raised floor plenumsRaised Floor to Ceiling Height: 15-20+ft
SECURITY
STAGING/TENANT OFFICE SPACE
Building and Perimeter: Ballistic glass enclosed security check-in, front window areas and loading dockSecurity Guards: Staffed 24/7Access Control: Electronic Security features with card key access and dual authentication with biometric readersCCTV: 24/7 surveillance of the interior/exterior of the facility
Office: 9 internal suites and 32,000 sf of adjacent office spaceStaging: 6 staging rooms (Phase I), 2 staging rooms (Phase II)
UPS SYSTEMS
GENERATORS
HEAT REJECTION SYSTEMS (HVAC)
ON SITE FUEL CAPACITY
FIRE PROTECTION
STS/PDUS
COMMUNICATIONS
Description: 32 Rotary power systems with 1,300 kW of critical output eachRedundancy: N+2, Each Phase
Description: 32 diesel-powered engine generators with 2,250 kW capacity eachRedundancy: N+2, Each Phase
Description: 16 centrifugal chillers with 1,150 Ton capacity eachRedundancy: N+2, Each PhaseChilled Water Storage: Two 500,000 gallon storage tanks for 24 minutes of continuous full load operation
Storage Tanks: Four 50,000 gallon underground diesel storage tanksNumber of Hours: Nominal 55 Hours
Description: Conventional smoke detector and laser based incipient smoke detection systems and double interlocked pre-action sprinkler system
STS Description: Dual input Static Transfer Switches (STSs)PDU Description: 300 kVA Power Distribution Units (PDUs)
POE: 4 separate network Points of Entry (POE) with diverse underground duct banks providing multiple entry points into the facilityConduits: Dedicated underground conduits to each computer room from multiple and diverse POEsMultiple Carriers: AvailableMeet-Me-Room: Available
COMPUTER ROOM SPECIFICATIONS Phase 1: Critical Load: 18.2 MWRooms 1-3: Critical Load: 0.433 MW, Approx. Gross SF: 2,700Rooms 4-13: Critical Load: 1.3 MW, Approx. Gross SF: 8,400Rooms 14-16: Critical Load: 1.3 MW, Approx. Gross SF: 9,900Phase 2: Critical Load: 18.2 MWRooms 18A-18B: Critical Load: 0.650 MW, Approx. Gross SF: 5,000Rooms 17, 19-26: Critical Load: 1.3 MW, Approx. Gross SF: 7,300-8,900Rooms 27A & 27B, 28A & 28B: Critical Load 2.6 MW, Approx. Gross SF: 13,900-14,300
Elec
trica
l/Mec
hani
cal
Com
pute
r Roo
m
Publ
ic
Circ
ulat
ion
SPAC
E AL
LOC
ATIO
NS
Data
/Tel
co
Supp
ort
Adm
inis
tratio
n/Of
fice
Dat
a C
ente
r C
H1:
Map
PHAS
E 2
PHAS
E 1
DIES
EL E
NGIN
E GE
NERA
TOR
(TYP
.)AR
EAWA
Y UP
S UN
IT
(TYP
.)SW
ITCH
BOAR
D (T
YP.)
AREA
WAY
MECH
. RM.
STOR
.
CENT
RIFU
GAL
CHIL
LER
(TYP
.)
TRAN
SFOR
MER
POE
MECH
. RM.
MECH
. RM.
MECH
. RM.
BR. R
M.BR
. RM.
BR. R
M.
COMP
UTER
RO
OMS
1-16
COMP
UTER
RO
OMS
17-2
8
STOR
.
SNOW
MEL
T
FP/P
L RM.
LOAD
ING D
OCK
OFFIC
E
6
19
7
1 2 3
48
5 1011
12
1415
16
13
17
18A
1920
2122
18B
2324
2526
28A
28B
27A
27B
MECH
RM.
LOB.
LOB.
BR. R
M.
W.M.
W.M.
W.M.
OFF.
ELEV
. OFF.
OFF.
MECH
RM.
OFF.
OFF.
SEC
ON
D FL
OO
R
FIRS
T FL
OO
R
MMR
XX
ELEV
.
OFFIC
EPO
E
CORR
IDOR
SE
C EQ
CORR
IDOR
MECH
RM.
CORR
IDOR
PO
E
AREA
WAY
AREA
WAY
STOR
.
POE
TELE
/COM
MMECH
RM.
MECH
. RM.
MMR
OFF.
CON.
For more information please contact [email protected]