• What is engineered timber? Why use it?• Research drivers

– Why are we interested in E.T.?• DCLG- Fire performance of SIPs

– What is a SIP?• Summary• Forward look

Page 3: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

What is engineered timber?• Any form of timber element not formed from

a continuous solid piece of wood.– Categories:

• Light timber (UK)• Large section (Scandinavia)

Page 4: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

Examples?

• Light timber frame:– Engineered floor joists/studs– Structural Insulated Panels (SIPs)

Page 5: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

Examples?

• Large section timber:– CLT – LVL– Glulam

Page 6: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

Why use it?

• Structural drivers:– Less defects– Less material for equivalent stiffness

• Construction drivers:– Easier to work with– Less time on site– Prefab = Less skilled labour

• Environmental drivers:– Less waste– Better thermal performance

Page 7: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

Why are we interested?• Research drivers:

– Redundancy = Fire Resistance (FR)• Excess material is a good thing• Removing material reduces inherent FR

– Improved thermal performance means:• Introduction of combustible insulation• Different fire dynamics• Mechanisms for fire spread

– Structural integrity• Type of failure (predictable? sudden?)

Page 8: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

The outcome

• 2 year CLG funded research project into the fire performance of SIPs and engineered floors.

• 7 full scale natural fire experiments• 20+ laboratory fire tests• Development of numerical models (thermal

& structural)

Page 9: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

STRUCTURAL INSULATED PANELS

(DCLG) The performance in fire of

Page 10: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

What is a SIP?

• Prefabricated lightweight units• Used as a principal load bearing element

– External & internal walls– Roofs– Floors (rarely)

• Sandwich construction comprising two structural veneers bonded to a light weight insulating core

70 to 250 mmFace layers

Insulated core

Page 11: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

What is a SIP? (2)

• SIPs currently approved for use up to 4 storeys in the UK (limited by FR)

• Can be viewed as a single structural element or an entire system

• Typically residential applications • Increased use in commercial applications

i.e. hotels, schools, offices. • Can be used as infill panels on multi-storey

framed structures.

Page 12: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

What is a SIP? (3)• SIPs assembled on site to form volumes• In the UK SIPs almost exclusively OSB PUR/PS

composites• Traditionally adopted with an engineered timber floor plate

Page 13: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

Project objectives• To determine how SIPs & EFJs fail when

exposed to a ‘realistic’ fire scenario.– 60 mins FR ≠ 60 min survivability in a real

fire• Hypotheses:

– (a) SIPs- combustible veneer & combustible core forming a structural composite……………..Not good!

– (b) EFJs- less redundant material…….sudden brittle collapse

Page 14: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

Objectives contd…

• Typical SIP system could not be defined by a single large scale fire test so we did 4!

• Target to represent multi-occupancy vs. single dwellings and EPS vs. PUR insulants

• Overarching objective- establish how the system fails.

Page 15: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

What did we do?

• 4 x full scale fire tests on SIP buildings– F1- 60 min EPS building– F2- 30 min EPS building– F3- 60 min PUR building– F4- 30 min PUR building– All with I section joist floors

• FR 30- Designed to fail• FR 60- Designed to survive burnout• How? Fire severity designed as 60 min equiv.

Page 16: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

EPS

PUR

Page 17: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...
Page 18: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

What did we do? (2)• Additional 3x full scale natural fire tests on

engineered floors– (J1) Traditional solid floor– (J2) I joist floor– (J3) Truss steel web floor

• Comparative performance

Page 19: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

The fires:

• 7 experiments conducted between Jan and Dec 2009

Page 20: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

What did we find out? (F1-F3)• Buildings survived burnout* without

collapse.• Passive fire protection stayed in place for

the duration of the experiment• Nominal deflection of the floor plate• But some interesting ‘post experiment

findings’*Fire brigade intervened after 80ish min to

accelerate cooling

Page 21: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

F1 and F3• Outcome generally positive but….

Page 22: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

What did we find out? (F2-F4)

• Mismatch between PFP spec and fire design….failures.

• Imminent floor collapses in both cases (terminated to save instruments etc)

• Extensive damage to wall panels and involvement of insulation

• Identification of system redundancy which prevented major collapse

Page 23: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

F2 & F4

Page 24: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

Summary of findingsEngineered floors:

– fail in a more sudden and brittle manner than ‘traditional’ joist floors

– have little inherent fire resistance. What does exist is afforded by the membrane mechanism whereby joists are tied together via MDF sheathing

Page 25: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

Summary of findings (SIPs)• Where PFP is appropriately specified and

installed: no failures and compartment is capable of surviving burnout without collapse or significant deformation (subject to exemplary workmanship)

• Where thermo-plastic insulants are used i.e. PS, significant damage/loss of composite action can occur as a result of heat transfer through internal linings without direct exposure

• However collapse didn’t occur due to redundancy i.e. alternative load paths through timber ring beams, corner studs and intermediate timber studs.

Page 26: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

SIPs…• Without studs whole building collapse would

have occurred.

Page 27: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

Concerns of stakeholders- myths and facts

Engineered floors fail in a more brittle/catastrophic manner than solid timberPotential for unseen fire spread (more pronounced in PUR panels)Potential for re-ignition after FRS intervention.

x SIP structures are not robust (they are if solid timber is present)

x Increased fire spread due to service penetrations (insufficient oxygen present)

x Pool fires as a result of melted EPS (low volume of polymer present)

Page 28: Danny Hopkin Research Engineer - Redbook · Danny Hopkin - Fire performance of engineered timber (2).pptx Author: WigstonN Created Date: 5/23/2011 3:44:45 PM ...

Forward look• Timber is here to stay• Buildings will get higher• Detailing and workmanship becomes more critical• Potential for site fires to become more common• Solutions?

– Invest in research– Promote performance based design

• The standard fire test is only a yard stick.• What about real fires?• What about system interactions?• Buildings in fire fail at interfaces.