DAMP-PROOFING Cavicloak - Cavity Trays
Transcript of DAMP-PROOFING Cavicloak - Cavity Trays
Preformed Damp Courses
USETo provide damp course protection that isshaped three-dimensionally and able to protectand service structural elements, level changesand projections.
SOLUTIONCavicloaks are preformed moulded DPC unitsfor use in cavity walls for use whereuninterrupted protection is required upwardlyand inwardly which calls for provision to bethree-dimensional.
Moulded from solid DPC Polypropylene,Cavicloaks are self-supporting and hold toprofile. Cavicloaks offer flexibility withoutsagging or distorting. Accordingly additionalsupport is not required when overlapping jointsin standard applications.
SIZESCavicloaks are supplied in a wide range ofshapes and running lengths to suit a wide rangeof cavity widths. A bespoke service also operatesto accommodate special requirements andcustomers’ specific needs.
When selecting or ordering Cavicloaks, there isalso the option of whether the top of the cloak isreturned into the inner leaf as illustrated, orterminates against it. It is the choice of thespecifier and attention is drawn to the Designers’Comments that highlight the considerations.
Cavicloak
• Ready-shaped modular DPC cloaks• Modular components eliminate site fabrication variances• Accurate scheduling and stock control• Upstand termination option (self-supporting or return into inner skin)• Ready to use - no wastage
Long lengths to run between cloaks supplied inmatching profile lengths of 2440mm unlessotherwise requested. Cavicloaks provide a reliable alternative tocutting and fabricating roll DPC on site, reducingtime, wastage and easing procurement andstock control.
PRODUCT NAME - GROUPCavicloak
CAVITY WIDTHS ACCOMMODATEDFrom 50mm up to 400mm
DIMENSIONSTo order – see popular styles illustrated
BESPOKE OPTIONSYes
TRADITIONAL CONSTRUCTION COMPATIBLEYes
TIMBER FRAME CONSTRUCTION COMPATIBLEYes self-supporting or Cavistrap option
NEW WORK APPLICATIONSYes
RETROFIT APPLICATIONSNo
MASONRY SKIN STYLESNo known limitation
UNDULATING MASONRY FACESCompatible
CURVED WALL ON PLAN APPLICATIONSYes – see Curved Wall entries
JOINTING METHODLap 150mm & sealing strip jointing
CONGRUENT WITH OTHER WALL ELEMENTSNo identified incompatibility
ARRESTED WATER EVACUATIONVia Caviweeps in perp joints
THERMAL TRANSMISSION OF MATERIALNegligible - 0.15 – 0.17
MATERIALPolypropylene DPC
COLOURBlack
EXTRUDES / COMPRESSES UNDER LOADNo
PACK SIZE Available individually
CFCCFC Free
ODPZero
REGULATION COMPLIANCEYes can be used to satisfy arrestment
MAY BE USED IF CAVITY INSULATION PRESENT?Insulation should not affect functionality
CAD DOWNLOADSYes
DESIGN CONSIDERATIONSCurved applications - see separate entry
Illustration shows achange of levelCavicloak in position.
18
DESIGNERS’ COMMENTS
When used at ground level, both skins of a cavity wall are level with each other. Building the Cavicloak into theinner skin at this level is the usual choice because a support course is normally at an appropriate height andreadily available. As both skins are raised they can drift out of level – especially if each is being built using adifferent masonry module. In such instances as higher levels of the wall are reached, the specifier may elect forself-supporting Cavicloaks requiring no inner skin support. If intermediate floor levels or similar masonry skinalignment opportunities exist, the specifier commonly has both choices available. Cavicloaks at ground level candual-function, arresting upwardly (rising) damp and also downwardly moving (wall penetrating) water, thusaddressing PD 6697:2010 - recommendations for the design of masonry structures to BS EN 1996-1-1 and BS EN1996-2. Always provide a water evacuation route (Caviweep) even if the wall is rendered, to comply with 6.2.7.7.1of PD 6697:2010 that states rain will penetrate and run down the inside face of a wall rendered externally.
DAMP-PROOFING
Telescopic adjustable ventilators (Type TAV) (to ventilate underfloor areas)have been built into the exterior cavity wall prior to bedding of theperimeter Cavicloak. Each ventilator has been extended in height to takeadvantage of the Cavicloak bedding level coinciding above it andproviding protection. This approach removes the necessity to individuallyprotect each ventilator at a lower course level.
HOW TO ORDERWe will take-off and schedule your requirements. Alternatively, state wall dimensions + profilerequired + number of angles and steps.
SPECIFICATION WORDINGCavicloaks by Cavity Trays of Yeovil SomersetBA22 8HU (01935 474769).Self-supporting / build-in profile. Sizes asschedule prepared by Cavity Trays Ltd.Request liability/conformity document uponcompletion.
PHONE 01935 474769 FAX 01935 428223 EMAIL [email protected]
20
DAMP-PROOFING
Cavicloak (continued)Preformed Damp Courses
• Ready-shaped modular DPC cloaks• Modular components eliminate site fabrication variances• Accurate scheduling and stock control• Upstand termination option (self-supporting or return into inner skin)• Ready to use - no wastage
DESIGNERS’ COMMENTS
Trays must step down towards the external leaf not less than 150mm. Numerous lintels also act as a DPC butwhere these are less than 150mm in height (commonly many are 140mm) they do not technically satisfy thedamp protection requirements demanded in Building Regulations Part C and British Standards unlessaccompanied with additional DPC protection providing the minimum dimension stipulated.
*Illustration shows a change of level cavicloak that requiresbuilding into exterior skin only.(Upstand is self-supporting)
Column Cloak (Supplied in two pieces) CC/CC/0270
Radon Internal AngleCC/RAD/IC/0250
Balcony CloakCC/BC/0570
Radon External AngleCC/RAD/EC/0260
Window Cill tray (Dependant on size) CC/UC/0350
Type C/P with pipe projecting through cloak CC/CP/0360
Stopend CC/SE/0410
StopendCC/SE/0160
Internal AngleCC/IC/0320
Cloak around vertical vent sleeveCC/CS/0440 CC/CS/050
Party Wall link cavicloakCC/PWL/0220
Threshold CavicloakCC/S/060
Column CavicloakCC/C/090
Threshold Step Down Cloak CC/TS/0630
Reveal Protection CloakCC/RP/0600
Change Profile / Corner CloakCC/CPC/0590
Column cloakCC/C/0400
Change of Level / Change of DirectionCC/SLIC/060
Internal Corner / Column CloakCC/ICC/0510
Column / Windpost CloakCC/CWP/0520
Change of Profile / Intersection SealCC/CPC/0540
Column CloakCC/C/0550
Level ChangeCC/LC/0560
Step down cloak (Small step) CC/LC/080
Internal Angle CC/IC/0370
PHONE 01935 474769 FAX 01935 428223 EMAIL [email protected]
1 2 3 4 5
9 10 11 12 13
17 18 19 20 21
25 26 27 28 29
33 34 35 36 37
21
PRODUCT NAME - GROUPCavicloak
CAVITY WIDTHS ACCOMMODATEDFrom 50mm up to 400mm
DIMENSIONSTo order – see popular styles illustrated
BESPOKE OPTIONSYes
TRADITIONAL CONSTRUCTION COMPATIBLEYes
TIMBER FRAME CONSTRUCTION COMPATIBLEYes self-supporting or Cavistrap option
NEW WORK APPLICATIONSYes
RETROFIT APPLICATIONSNo
MASONRY SKIN STYLESNo known limitation
UNDULATING MASONRY FACESCompatible
CURVED WALL ON PLAN APPLICATIONSYes – see Curved Wall entries
JOINTING METHODLap 150mm & sealing strip jointing
CONGRUENT WITH OTHER WALL ELEMENTSNo identified incompatibility
ARRESTED WATER EVACUATIONVia Caviweeps in perp joints
THERMAL TRANSMISSION OF MATERIALNegligible - 0.15 – 0.17
MATERIALPolypropylene DPC
COLOURBlack
EXTRUDES / COMPRESSES UNDER LOADNo
PACK SIZE Available individually
CFCCFC Free
ODPZero
REGULATION COMPLIANCEYes can be used to satisfy arrestment
MAY BE USED IF CAVITY INSULATION PRESENT?Insulation should not affect functionality
CAD DOWNLOADSYes
DESIGN CONSIDERATIONSCurved applications - see separate entry
Change of Profile / Change of Direction /Change of Level CC/CLCP/IC/0270
Corbel CloakCC/CC/0580
Step down cloak (Large step) (150mm - 600mm High) CC/LC/0340
Change of LevelCC/LC/0610
External Corner/ Column CloakCC/EC/0620
Cloak over ventCC/SCC/0330
Windpost CloakCC/WC/0280
Change of Profile CloakCC/COP/0190
Windpost cloakCC/WC/0430
External AngleCC/EC/0390
Level Change /External corner CavicloakCC/S/0110
Masonry Support / CloakCC/MS/0530
External AngleCC/EC/0380
Windpost Cloak (Handed) CC/WRS/0290
Stopend cavicloak CC/SE/040
Cavicloak (continued)Illustration shows achange of levelCavicloak in position.
Preformed Damp Courses
• Ready-shaped modular DPC cloaks• Modular components eliminate site fabrication variances• Accurate scheduling and stock control• Upstand termination option (self-supporting or return into inner skin)• Ready to use - no wastage
DAMP-PROOFING
PHONE 01935 474769 FAX 01935 428223 EMAIL [email protected]
6 7 8
14 15 16
22 23 24
30 31 32
38 39 40