Wide selection with
the inverter series
Economy and comfort are essential to
store and office air conditioning.Our varied lineup meets customer needs when itcomes to functions and indoor unit types.
Enhanced Comfort with
Daikin InverterComfortable air conditioning is achieved through variable output control made possible by the inverter, which continuallymaintains the set temperature while detecting load, which varies with time of day and number of room occupants.
P r o d u c t L i n e u p
FBQ71BV1A
RXS71FVMA
ROUND FLOWOUN FLOWROUND FLOW
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
CEILING SUSPENDED TYPE
CEILING MOUNTED
CASSETTE TYPE
COMPACT MULTI FLOW
CEILING MOUNTEDCASSETTE TYPE
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
CEILING MOUNTED
BUILT-IN TYPE
DUCT CONNECTION
MIDDLE/HIGH STATIC
PRESSURE TYPE
Outdoor unit
Indoor unit
FHQ35BVV1B FHQ50BVV1B FHQ60BVV1B
RKS35AVMG RKS50AVMG RKS60AVMG
RKS25AVMG RKS35AVMG RKS50AVMG RKS60AVMG
FFQ35BV1BFFQ25BV1B FFQ50BV1B FFQ60BV1B
RXS50FAVMA RXS60FVMA
FBQ50BV1A FBQ60BV1A
Round Flow
RXS71FVMA
1
25 35 50 60 71
RKS25AVMG RKS35AVMG RKS50AVMG
RXS50FAVMA
RKS50AVMG RKS60AVMG
RKS60AVMG
RXS60FVMA
Series
-
8/9/2019 Daikin Skyair
3/40
Energy savings withhigh-efficiency inverterThe outdoor unit is equipped with a reluctance DC scroll compressor that utilizes the latest technology. It bringsout the full energy-saving potential of the inverter, which controls power used in accordance with load variation.
New, compactoutdoor unitThe outdoor unit is easy to install in storesand offices where space is limited.
Page 5
Page 9
Page 11
Page 13
Page 15
Page 17
FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B
RZR71KUV1 RZR100KUV1 RZR125HUY1
FHQ125BVV1B
RZR125KUV1
FHQ100BVV1B
RZR100HUY1
FCQ71KVEA
71
FCQ100KVEA FCQ125KVEA FCQ140KVEA
100 125 140
RZR125HUY1
FCQ125KVEA
RZR125KUV1
FCQ100KVEA
RZR100HUY1RZR100KUV1RZR71KUV1 RZR140HUY1
FCQ140KVEA
RZR140KUV1
FBQ71DV1 FBQ100DV1 FBQ125DV1 FBQ140DV1
RZR125HUY1
FBQ125DV1
RZR125KUV1
FBQ100DV1
RZR100HUY1RZR100KUV1RZR71KUV1 RZR140HUY1
FBQ140DV1
RZR140KUV1
RZR71KUV1 RZR100HUY1RZR100KUV1 RZR125HUY1 RZR140HUY1
2
O U T D O O R U N I T
RZR140KUV1RZR125KUV1
NEW
NEW NEW NEW NEW NEW NEW NEW
NEW
-
8/9/2019 Daikin Skyair
4/40
Non-inverter
Inverter Time
Runningcurrent
Starting current
Time
Running current
Current
Current
At startup, inverter raises frequency smoothly,
eliminating the starting current spike.
Soft starter is
unnecessary, making
electrical installation
work much simpler.
At startup, full power is used to achieve the set temperaturequickly. Then, the capacity is adjusted according to the outdoortemperature changes and subtle indoor load changes toachieve fine capacity control resulting in a more stable room
temperature.
Inverter performs variable control of frequency,which determines air conditioners powerperformance.
360airflow with improvedtemperature distribution.
Enhanced comfort with Inverter
Small temp.differenceCools a room
in less time
Cooling operation
Inverter power control
Non-inverter type air conditioner
Time
Temp
Set temp
Non-inverter type air conditioners must be switched onand off repeatedly, causing large fluctuationsof the room temperature.
Comfortable airflow
Comfortableomfortable
Round Flow cassetteound Flow cassette
Comfortable
Round Flow cassette
360 airflow
realises uniform
airflow distribution.4-way flow leaves areas
that cannot be covered.
Greater comfortImproved energy saving
Round Flow typeConventional
4-way flow type
ROUND FLOWOUN FLOWROUND FLOW
3
-
8/9/2019 Daikin Skyair
5/40
Models have received Singapore's 4 Tick Energy Label, which is the
highest energy-efficiency rating for inverter type air conditioner.
The mandatory labelling scheme was introduced by Singapore
National Envirionment Agency.
48
49
RZR71KU
Sound level*(dB(A))
RZR100KU/100HU
50RZR125KU/125HU
50
47
49
45
46RZR140KU/140HU
Rated Night Quiet Mode
Energy savingnergy savingEnergy saving4 Tick Energy Label
Optimised Efficiency with R-410A
COP is equal to capacity (kW) divided by power
consumption (kW), and the larger the COP value, the higher
the energy efficiency, enabling cooling and heating with less
electricity and increasing the energy saving performance.
Note :Rated cooling capacities are based on the following conditions: Indoortemp., 27CDB, 19.0CWB; outdoor temp. 35CDB Equiv. refrigerationpiping, 7.5 m (horizontal).
What is COP(Coefficient of Performance)
COP
1
2
3
4
FCQ100KVEA FCQ125KVEA FCQ140KVEARZR100KUV1 RZR125KUV1 RZR140KUV1
RZR100KUV1
Quiet operationuiet operationQuiet operationNight quiet
operation function
Navigation Remote Controlleravigation Remote ontrollerNavigation Remote ControllerClear display, Simple operation,
"Navigation Remote Controller"!
3.40
Cooling*
FCQ71KVEARZR71KUV1
3.32
Cooling*
2.83
Cooling*
3.57
Cooling*
RKS25AVMG RZR71KUV1 RZR100KUV1
4
Note :
Anechoic chamber conversion value, measured according to JISparameters and criteria. During operation these values are somewhathigher owing to ambient conditions.
Dot matrix display
Backlight display
Large buttons and arrow keys
Guide on display
Weekly schedule timer Multilingual display
Clear Display
Other Features
Simple operation
Wired Remote ControllerBRC1E61(Optional)
-
8/9/2019 Daikin Skyair
6/40
*1 Cooling only
MouldpreventionComfort Work & Servicing Control features OthersOptionsFeature
Features
Model
Accessory required for indoor unit
Option
*1Applicable when wired remote controller is used
CEILING MOUNTED CASSETTE TYPE
FCQ71K/100K/125K/140K
Swingp
atternselection
Switcha
blefanspeed
Autosw
ing
Program
me"Dry"
Highce
ilingapplication
Year-roundcooling
applicable
Timerselector
Drainp
umpmechanism
Precha
rgedfor
upto30m
Long-li
fefilter
Mould-resistanttreatment
forfilter
Filtersign
Ceiling
soilingprevention
Lowgaspressure
detection
Emerge
ncyoperation
Self-d
ia
gnosisfunction
Ultralong-l
ifefilter
High-ef
ficiencyfilter
Freshairintakekit
Controlby2remote
controllers
Auto-re
start
Controlby1remote
controller
Externa
lcommand
control
Central
remotecontrol
Interloc
kcontrol
PEfin
Twoselectable
temper
ature-sensors
Round Flow
ROUND FLOWOUN FLOWROUND FLOW
Uniform 360 airflow cassette air conditioneris setting tomorrow's standards.Uniform 360 airflow cassette air conditioneris setting tomorrow's standards.
GOODDESIGN
AWARD 2004
IN JAPAN
5
Note: Remote controller cable not included. Cables must be procured locally.
BRC1E61
Navigation RemoteController(Wired Remote Controller)
BRC7F632F
A signal receiver must be added to the indoor unit.
Wireless remote controller and signal
receiver unit are sold as a set.
Wireless LCD remote controller
Signal receiver unit(Installed type)
Note: Remote controller cable not
included. Cables must be
procured locally.
Wired LCD remote controller
Wired LCD remotecontroller with weeklyschedule timer
BRC1C61
BRC1D61
-
8/9/2019 Daikin Skyair
7/40
Airflow
distribution
Creates uniform
comfort throughout
the space
Comfort enhanced by Round Flow!
With uniform temperaturedistribution Enhanced Comfort
Greater comfortImproved energy saving
Condition after exposure
to the smoke of 600
cigarettes in 1 m3
enclosed space.
Treatedsurface
Untreatedsurface
Grimysurface
Resistssoiling
External panels are treated with a coating that
repels dirt.
Anti bacterial treatment, that includessilver ions is used which may assist in
preventing the growth of microorganisms
that cause smells and clogging.
Avoids ununiform temperature and uncomfort caused by drafts.
To prevent dirt sticking to the
external panels, they have
been coated with a surface
treatment.
Because air flows out from corner outlets, comfort spreads more widely.
360 airflow Air movement is gentle with Round Flow
Dew does not easily form on and dirtdoes not cling to non-flocking louvres.
It is easy to clean.
Non-flocking horizontal louvresBactericidal treatment for
drain panPrevents mould and microorganismsgrowing out of the dust and moisture
that adheres to the filters.
Filter has anti-mould andbactericidal treatment
Grime prevention and bactericidal coating: Make cleaning easier.
Adapts easily to the installation space.
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing member (option) must be used to
close each unused outlet.
3-way flow L-shaped2-way flow
Opposite2-way flow
(E.g., installed ina corner)
(E.g., installed ina long room)
(E.g., installednear a wall)
(E.g., installed inmiddle of ceiling)
4-way flow also possible.
All-round flow
360airflow canmaintain comforteven if airdischarge speed islower.
Typical flow patterns There are a total of 23 flow patterns.
If you raise the set temperature by 1 to 1.5C,and velocity is decreased by 25%,You still obtain the same feeling temperature and comfort.
6
Operation sound increases when using 2-way or 3-way flow.
-
8/9/2019 Daikin Skyair
8/40
CEILING MOUNTED CASSETTE TYPE Round Flow
Quick and easy to installJust 256 mm high. Installable in tight
ceiling spaces (71K)
7
Fine square panels Compact body and quiet operation
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.
**Wireless remote controller does not have a temperature-sensor.
Note : Anechoic chamberconversion value, measuredaccording to JIS parametersand criteria. Duringoperation these values are
somewhat higher owing toambient conditions.
Note: Air direction is set to the standard position when the unit is shipped from the factory.The position can be changed from the remote controller.
Panel size is same for all models, FCQ71-140K.It is easy to maintain a neat appearance whenmultiple units are installed.
Optimal comfort and convenienceassured by air discharge modes
Both indoor unit and wired remote controller (option (BRC1D61,BRC1E61)) containtemperature- sensors. Temperature sensing can be set at the unit or, tofurther improve comfort level, closer to the target area at the wired remotecontrol. This feature must be set during commissioning by the technicians.
Two selectable temperature-sensors
Even in spaces with high ceilings, a comfortable airflow is carried down to
the floor level.
Suitable for high ceilings
Operation starts when the preset time of the ON timer elapses and stops
when the preset time of the OFF timer elapses.
Timer selector
Indoor unit High Low
125K 44 34
140K 44 36
100K 43 32
71K 35 28
dB(A)
Same for
all models
Air direction
Auto air
direction control
Settable to 5 different
levels between 15and 60
Settable to 5 different
levels between 25and 60
Auto-swing between15and 60
Auto-swing between25and 60
Recommended for shops withlight coloured ceilings that
must be kept spotless.
Standard position to
prevent draft.
Standard setting Setting to prevent soiling of ceiling*
The air direction is set automatically to thememorised position of the previous air direction.
Desired
situation
Auto-swing
5-levelsair directionsetting
*Closing of the corner discharge outlets is recommended.
Number of air discharge outlets used
71K4-wayflow
3-wayflow
2-wayflow
4-wayflow
3-wayflow
2-wayflow
100K140K
3.1 m
3.4 m
4.0 m
All round
flow
2.7 m
3.0 m
3.5 m
3.0 m
3.3 m
3.5 m
3.5 m
3.8 m
-
3.4 m
3.9 m
4.5 m
All round
flow
3.2 m
3.6 m
4.2 m
3.6 m
4.0 m
4.2 m
4.2 m
4.2 m
-
StandardCeilingheight
High ceiling
High ceiling
Criteria for ceiling height and number of air discharge outlets
950m
m 950mm
Note: Factory settings are for standard ceiling height and all-round flow.
High ceiling settings (1) and (2) are set with the remote controller.
256 mm *1 265 mm *2
*1 298 mm high with 100K140K
*2 303 mm high with 100K140K
All models can be installed without
using lifter because of the light weight.
Easier connection with the centralisedcontrol system
Low gas pressure detection
Drain pump is equipped as standard
accessory with 850 mm lift.
Transparent drain socket
Each corner of the unit has an Adjuster Pocket that
lets you easily adjust the unit's suspended height.
Since the orientation of
the intake grill can be
adjusted after installing,
the direction of the intakegrill lines can be unified
when multiple units
are installed.
Note: If the wireless remote control option is installed, a light receptor
unit is housed in one of the adjuster pockets.
Easy height adjustment
Installable inany direction
Because the drain socket istransparent, after the drain piping
has been installed, it is easy to
check if the drain come out
through the socket.High setting provides maximum reach while low
setting minimises drafts.
Switchable fan speed: High/Low
175 mm
850mm
-
8/9/2019 Daikin Skyair
9/408
Options required for specific operating environments
High-efficiency filterAvailable in two types: 65% and 90% colorimetry.
Using this kit, a
duct can be fitted
to increase the
intake of outdoorair.
*Connecting ducts, insect nets, fire dampers, air filters, and other
parts should, as required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary.
Optional PCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced
through the kit is limited to 10% of the maximum airflow rate of the
indoor unit. Introducing higher quantities will increase the
operating sound and may also influence temperature sending.
Fresh air intake kit
Even in smoky environments wherethe air conditioning is on most of
the time, the ultra long-life filter only
has to be changed once a year.
Ultra-long-life filter Panel spacerUse when only minimal space is available between drop
ceilings and ceiling slabs.
Sealing member of air discharge outletSealing members block air discharge openings not used in 2-way or 3-way blow.
Branch duct(direct-connection round duct)
Outside
Note: Use of options will increase operating sound.
The units can be installed in the following different ways.
Note: Some ceiling constructions may hinder installation.
Contact your Daikin Dealer before installing your unit.
Direct installation type
Flexible duct
T-joint pipe
Intake duct(procured locally)(duct length: 4 m max.)
Intake duct(procured locally)(duct length: 4 m max.)
Connectionchamber
Suctionchamber
Duct flange(with insulation material)
Intake duct(procured locally)
Chamber type
(with T-joint pipe and without fan)
Flexible duct(procured locally)
T-joint pipe(procured locally)
Chamber type
(without T-joint pipe and fan)
KDDP55X160KDDP55K160KKDDP55K160
Easier to maintain
With ultra-long-life filters (option ), maintenance is not required in normal shops or offices
for up to four years.
The condition of the drain pan anddrain water can be checked by
removing the drain plug and
intake grille.
Drain plug
Justope
nthe
intakegri
lle!
40mm
Panel spacer
A round duct can be attached without the need for a chamber.
A flanged port for direct connection of a round duct is
provided. An existing branch duct chamber can also be fitted
(square slit hole).
Connectionchamber
Suctionchamber
Smoky atmosphere: annual filter change
Ordinary store or office: filter change every 4 years
*For dust concentration of 0.3 mg/m3 (Requires separately sold Air Cleaner.)1 year (Approx. 5,000 hr) 15 hr/day x 28 day/month x 12 month/year
*For dust concentration of 0.15 mg/m3
4 years (Approx. 10,000 hr) 8 hr/day x 25 day/month x 4 years
Note:
-
8/9/2019 Daikin Skyair
10/409
Cooling only
MouldpreventionComfort Work & Servicing Control features OthersOptionFeature
Features
Model
*1Applicable when wired remote controller is used*2Applicable to RKS25/35/50/60AVMG outdoor units
COMPACT MULTI FLOWCEILING MOUNTEDCASSETTE TYPE
Quiet, decor-blending form and easyinstallation in new or old buildings.Quiet, decor-blending form and easyinstallation in new or old buildings.
Swingp
atternselection
Switcha
blefanspeed
Autosw
ing
Program
me"Dry"
Year-roundcooling
applicable
Timerselector
Drainpumpmechanism
Prechargedfor
upto10m
Long-lif
efilter
Mould-resistanttreatment
forfilter
Filtersign
Emerge
ncyoperation
Self-diagnosisfunction
Freshairintakekit
Control
by2remote
controllers
Auto-re
start
Control
by1remote
controller
Externa
lcommand
control
Central
remotecontrol
Interloc
kcontrol
PEfin
Twoselectable
temperature-sensors
FFQ25B/35B/50B/60B
*1 *2
Accessory required for indoor unit
Option
BRC7E531W
A signal receiver must be added to the indoor unit.
Wireless remote controller and signalreceiver unit are sold as a set.
Wireless LCD remote controller
Signal receiver unit
(Installed type)
Note: Remote controller cable not included. Cables must be procured locally.
BRC1E61
Navigation RemoteController(Wired Remote Controller)
Note: Remote controller cable not
included. Cables must be
procured locally.
Wired LCD remote controller
Wired LCD remotecontroller with weeklyschedule timer
BRC1C61
BRC1D61
-
8/9/2019 Daikin Skyair
11/40
25B 29.5 24.5
35B 32 25
10
CompactSized to fit inside 600mm wide
ceiling grids
Two selectable temperature-sensors
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.
**Wireless remote controller does not have a temperature-sensor.
Designed for low draft
performance
Consistent comfort throughout
Quiet operation has been achieved even with a
compact body and developed spiral hub cover that
reduces the static pressure inside the indoor unit.
Both indoor unit and wired remote controller (option (BRC1D61,BRC1E61)) containtemperature- sensors. Temperature sensing can be set at the unit or, to furtherimprove comfort level, closer to the target area at the wired remote control.This feature must be set during commissioning by the technicians.
High setting provides maximum reach while low setting minimises drafts.
Switchable fan speed: High/Low
Drain pump is equippedas standard accessory
with 750 mm lift.
Comfortable
QuietQuiet, small-diameter fan
Multi-Flow System Air direction can be
selected according to
installation.1 pattern
4-way flow
4 patterns
3-way flow
1 pattern
2-way flow
" " denotes piping direction. Drain piping
" " denotes sealing member for air discharge
outlet (option) .
Note: For 3-way or 2-way flow installation, the sealing
member for air discharge outlet (option) mustbe used to close off the unused outlet(s).
Note: Operation sound increases
when using 2-way or 3-way flow.
Spiral hub cover
750 mm
Settable to 5 different levels
between 0and 35
Settable to 5 different levels
between 0and 60
Settable to 5 different levels
between 25and 60
Auto-swingbetween 0and 35
Auto-swingbetween 0and 60
Auto-swingbetween 25and 60
Draftpreventionsetting(Set on site)
(Set on site)
Standardsetting
Setting topreventsoiling ofceiling
Auto-swing operationdistributes conditioned airmore evenly.
Airfow angle can be adjustedin accordance with roomconditions.
Auto-swing
0 0
0
25
60 60
0
35
25
60
35
60
5-levels air direction setting
Horizontal flow0 0
Less draftcan be felt
575 mm
575 mm
700 mm
700 mm
286mm
50B 36 27
High Low
60B 41 32
Fits without theneed to cut T-bargrid
T bar
600 mm 600mm
Decoration
panelisalso
compact.
Note: This angle above is provided as a guide. It may differ depending on the installation site.
Ceiling panel
Indoor unit
The switch box is built in to the
unit, so maintenance is possible
by simply removing the grill. An
inspection opening is notrequired even for modules other
than 600 x 600.
Note : Anechoic chamber conversion value, measured according to JISparameters and criteria. During operation these values are somewhat higher
owing to ambient conditions.
dB(A)
-
8/9/2019 Daikin Skyair
12/4011
Cooling only
MouldpreventionComfort Work & Servicing Control features OthersFeature
Features
Model
*3 *3*2 *1Installable on max. 3.5 m high ceiling*2Applicable when wired remote controller is used*3Applicable to RZR71KU, 100KU, 125KU, 140KU, RZR100HU, 125HU, 140HU outdoor units
Prechargedfor
upto30m
Long-lif
efilter
Mould-resistanttreatment
forfilter
Filtersign
Lowgaspressure
detectio
n
Emerge
ncyoperation
Self-d
iagnosisfunction
Control
by2remote
controllers
Auto-re
start
Control
by1remote
controller
Externa
lcommand
control
Central
remotecontrol
PEfin
Interloc
kcontrol
Drainpumpmechanism
Switcha
blefanspeed
Autosw
ing
Program
me"Dry"
Highce
iling
application*1
Year-roundcooling
applicable
Timerselector
Twoselectable
temper
ature-sensors
CEILING SUSPENDED TYPE
Upgrade to a quiet andcompact system.Upgrade to a quiet andcompact system.
FHQ35BV/50BV/ 60BV/71BV 100BV/125BV
A signal receiver must be added to the indoor unit.
Wireless remote controller and signal
receiver unit are sold as a set.
Wireless LCD remote controller
Signal receiver unit (Installed type)
Note: Remote controller cable not included. Cables must be procured locally.
BRC1E61
Navigation RemoteController(Wired Remote Controller)
Note: Remote controller cable not
included. Cables must be
procured locally.
Wired LCD remote controller
Wired LCD remotecontroller with weeklyschedule timer
BRC1C61
BRC7EA66
BRC1D61
Accessory required for indoor unit
Option
-
8/9/2019 Daikin Skyair
13/4012
* For dust concentration of 0.15 mg/m3
50
(mm)
Uses quiet stream fan and other quiettechnologies.
Turbulent flowis produced
Non-dew flap
Straighteningvane
Quietstream fan
60BV 39 3350BV 38 33
Indoor unit High Low
35BV 37 32
71BV 39 35
100BV 42 37
125BV 44 39
195
100BV 125BV
960 1,160 1,400 1,590
680
Drain pump kit(built inside main unit)
Height
Indoor unit
Width
Depth
35BV/50BV 60BV/71BV
600 mm
Quiet operation
Easier to maintain
Sound operation has been reduced on the exposedceiling suspended type unit.
Two selectable temperature-sensors
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.
**Wireless remote controller does not have a temperature-sensor.
Absence of bristles minimises
clinging dirt and simplifiescleaning.
Oil resistant grille
Oil-resistant plastic is used for the air dischargegrille. This satisfies durability in restaurants and
other similar environments.
Note: Intended for use in salons, dining rooms, and ordinary sales
floors, this specification is not suitable for kitchens or other
harsh environments.
For all maintenance tasks, access is
from bottom surface.
Two time settings (2500 hrs and 1250 hrs) are available to match the
installation environment. Maintenance time warning is displayed on
the remote controller (filter sign).
It is easy to wipe dirt off the flat side and lower
surfaces of the unit.
Easy-clean, flat surfaces
Non-dew flap without bristles
Long-life filter lasts about half
year * maintenance not required
Diffuses comfortable airthroughout the room
Auto-swing (up&down) brings comfort to the room.
Installation flexibility forfreedom of design
Both indoor unit and wired remote controller (option (BRC1D61,BRC1E61)) containtemperature- sensors. Temperature sensing can be set at the unit or, tofurther improve comfort level, closer to the target area at the wired remotecontrol. This feature must be set during commissioning by the technicians.
Dehumidification is microprocessor controlled to prevent abrupt and
uncomfortable changes in air temperature.
Programme "Dry"
Wide air discharge
openings produce aspreading 100 airflow
Air is blown up to 50 in
the downward direction.
Switchable fan speed: High/Middle/Low
Installable on
ceilings 3.5 m high
100
Flexible installation
*Water used in the test-run can now be drained from theair discharge opening rather than from the side as wasformerly the case.
The unit fits more snugly into tightspaces.
Drain pump kit (option)
can be easily incorporated
Drain pipe connection can be doneinside the unit. refrigerant and drain
pipe outlets are at the same
opening.
Uniform height and
depth. Compact
design for small-
capacity models to
meet tighterdimensional
1,160 mm30 mm or more
30 mm or more
For 71BV indoor unit
Note : Anechoic chamber conversion value, measured according to JISparameters and criteria. During operation these values are somewhat higherowing to ambient conditions.
dB(A)
Pipes more easily rigged, tooPlastic panels are used to conceal piping holes. Holes can be easily
punched out without requiring special tools.
Low gas pressure detection
All wiring and internal servicing can be done from under the unit
(Applicable to RZR71KU, 100KU, 125KU, 140KU, RZR100HU, 125HU, 140HU outdoor units)
-
8/9/2019 Daikin Skyair
14/40
Control featuresWork & ServicingComfort OthersOption
CEILING MOUNTED BUILT-IN TYPE
Clever and compact mini ducted unitprovides comfort and flexibility.Clever and compact mini ducted unitprovides comfort and flexibility.
Features
Feature
Model
Cooling only
FBQ50B/60B/71B
*1Applicable when wired remote controller is used
FBQ50BV1A
BRC4C62
A signal receiver must be added to the indoor unit.
Wireless remote controller and signal
receiver unit are sold as a set.
Wireless LCD remote controller
Signal receiver unit
(Separate type)
13
*1 Switchablefans
peed
Programme"Dry"
Year-roundcooling
applicable
Timerselector
Prechargedfor
upto10m
Filtersign
Self-d
iagnosisfu
nction
Lowg
aspressure
detection
PEfin
Highefficiencyfilteroption
Controlby2rem
ote
controllers
Auto-restart
Controlby1rem
ote
controller
Externalcomma
nd
control
Centralremote
control
Interlockcontrol
Twoselectable
temperature-sensors
Note: Remote controller cable not included. Cables must be procured locally.
BRC1E61
Navigation RemoteController(Wired Remote Controller)
Note: Remote controller cable not
included. Cables must be
procured locally.
Wired LCD remote controller
Wired LCD remotecontroller with weeklyschedule timer
BRC1C61
BRC1D61
Accessory required for indoor unit
Option
-
8/9/2019 Daikin Skyair
15/40
CompactCompact design of built-in type helps blend
with interior decor.
Work & Servicing
Comfortable
Height reduced to allow installation in confined spaces.
Flexibly adapts to shop interiors
L-shaped space U-shaped space Long space
To cope with the challenges of L-shaped or U-shaped spaces, itis possible to install the air discharge unit away from the main unit.At the same time, different types of architectural space can be
kept comfortable.
The height of the unit is a mere 300* mm. It can be
installed in a narrow ceiling space.(when access panel is used.)
Provided with condensate drain pump, waking drainpiping easier in awkward spaces.
External static pressure can be set depending onduct length, presence of high-efficiency filter, andother installation conditions.
Access panel
250mm
Access panel
300
mmm
300mm
Two selectable temperature-sensors
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from
another room. **Wireless remote controller does not have a temperature-sensor.
Both indoor unit and wired remote controller (option (BRC1D61,BRC1E61))
contain temperature-sensors. Temperature sensing can be set atthe unit or, to further improve comfort level, closer to the target areaat the wired remote control.This feature must be set during commissioning by the technicians.
(mm)
71B 34 30
60B 34 30
Indoor unit High Low
50B 33 29
30060B/71B
1,000
800
HeightIndoor unit
Width
Depth
700
50B
Quiet operation
Dehumidification is microprocessor controlled to prevent abrupt
and uncomfortable changes in air temperature.
Programme "Dry"
Switchable fan speed: High/Low
dB(A)
Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria.During operation these values are somewhat higher owing to ambient conditions.
*350mm high with 100B8-125B8.
High Standard
88
Indoor unit
External static pressure pattern
50B71B 49 20
Low
External static pressure is set to standard when the unit is shipped from the factory.
(Pa)
14
-
8/9/2019 Daikin Skyair
16/40
Control featuresWork & ServicingComfort OthersOption
DUCT CONNECTION MIDDLE HIGH STATIC PRESSURE TYPE
Flexible use of space is made possible usingducts to create a room filled with comfort.Flexible use of space is made possible usingducts to create a room filled with comfort.
Features
Feature
Model
Cooling only
*1Applicable when wired remote controller is used*2Applicable to RZR71KU, 100KU, 125KU, 140KU, RZR100HU, 125HU, 140HU outdoor units
15
*1 *2 *2 *2Switchablefans
peed
Programme"Dry"
Year-roundcooling
applicable
Timerselector
Prechargedfor
upto30m
Filtersign
Self-diagnosisfu
nction
Lowg
aspressure
detection
PEfin
Highefficiencyfilteroption
Controlby2rem
ote
controllers
Auto-restart
Controlby1rem
ote
controller
Externalcomma
nd
control
Centralremote
control
Interlockcontrol
Twoselectable
temperature-sensors
FBQ71D/100D/125D/140D
NEW
BRC4C62A signal receiver must be added to the indoor unit.
Wireless remote controller and signal
receiver unit are sold as a set.
Wireless LCD remote controller
Signal receiver unit
(Separate type)
Note: Remote controller cable not included. Cables must be procured locally.
BRC1E61
Navigation RemoteController(Wired Remote Controller)
Note: Remote controller cable not
included. Cables must be
procured locally.
Wired LCD remote controller
Wired LCD remotecontroller with weeklyschedule timer
BRC1C61
BRC1D61
Accessory required for indoor unit
Option
-
8/9/2019 Daikin Skyair
17/40
Increased freedom of designthanks to variable controlover external static pressure
Comfort airflow achieved in accordance withconditions such as duct length.
Using a DC fan motor, the external static pressure can becontrolled within a range of 50 Pa to 200 Pa.
Thin, lightweight indoorunit makes delivery andinstallation easy.
With a height of only 300 mm, installation is
possible even in buildings with narrow ceiling
spaces.
Drain pump is equipped as standard accessory
with 700 mm lift.
300
100D 125D 140D
1,000
36
1,400
700
Height
Indoor unit
Width
Depth
46Machine Weidth
71D
16
Freely control external static pressure
50 Pa 200 Pa
Set to high static pressure for
advanced needs such as when
using dampers and long ducts.
Set to low static
pressure when ducts
are short.
Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
Ventilation grille
Door-installedventilation grille
Ventilation grille
Wall-installedventilation grille
Under-door cutout
Under-door cutoutWhen air conditioning two roomssimultaneously, the air discharged into eachroom must be circulated back to the air
conditioner. To achieve this, a ventilationduct should be installed for each room or oneof the indicated ventilation grilles should beinstalled on the partitioning wall or under thedoor between the rooms.
Ventilates air through
the partitioning wall.
(See right)
Partitioning wall
Note: The under-door cutout method should be used only when there is a small volume of airflow.
(mm)
(mm)
(mm)
(kg)
Quiet operation
When testing standard integrated ceiling units that employ ductwork, much time used to be required to adjust airflow to the rightlevel. Thanks to the ability provided by Daikin to automatically
perform this troublesome adjustment using a remote controller,this step is now quick and easy. (Adjust by H tap .)
1. Adjust to approximately 10% of the rated H tap airflow.2. Once actual operation has begun, adjustment of the rated airflow is not possible.
Reduced installation time
Use remote controller to adjust airflow
Anti bacterial treatment, that includes silver ions is used which
may assist in preventing the growth of microorganisms that cause
smells and clogging.
Bactericidal treatment for drain pan
Maintenance is easy because the drain pan can be removed.
Easy maintenance
Clean
Both indoor unit and wired remote controller (option) containtemperature- sensors. Temperature sensing can be set at the unitor, to further improve comfort level, closer to the target area at thewired remote control.This feature must be set during commissioning by the technicians.
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from anotherroom.
**Wireless remote controller does not have a temperature-sensor.
Two selectable temperature-sensors
Comfortable
dB(A)
300
100D 125D 140D
High
Low
71D
38 40 4037
33 36 3632
700 mm
300mm
-
8/9/2019 Daikin Skyair
18/40
OUTDOOR UNIT
The final word ininverter technology
RZR100KUV1
RZR125KUV1RZR140KUV1
RZR71KUV1
Easy installation and maintenance
Pre charged for up to 30 metres
4-direction piping offers greaterlayout freedom
50 mpiping length
Easy centralised installation with
the module oriented design
Separationavailable
-10
0
10
20
30
40
50
46CDB
Cooling
-5CDB
Outdoor temp(CDB)
Depth of 71KU, 100-140KU, 100-140HU,are standardised as 320 mm. Horizontalcontinuous mounting is available.
If refrigerant piping length does not exceed30 m, there is no need for on-site gascharging.
A pump-down switch is provided to make iteasier to collect refrigerant if the unit is tobe moved or layout modified.
Facilitates pump down(Refrigerant recovery function)
Effective gas monitoring reduces the laborrequired for operation, maintenance, andrepairs.
Low gas pressure detection
function
Operation range
Reduced installation work thanks to light,compact outdoor unit.
Space saving
Compact design with reduced height
The maximum capacity is maintained
within a set level of power consumption,
which makes it possible to keep comfort
and effective demand control.
The outer panel for the piping connectionpart of the front, right side and backsidecan be removed and is easier for post-installation piping work.
17
Fittings can be mounted on the fourlocations, right/ left on front and back sideof the outdoor unit.
Reinforcing wire fittings
(option) are available
Safety
As the bottom frame is
subject to corrosion,
corrosion-proof galvarium
steel plate is adopted toenhance the durability.
Heat exchange fins provided
with anti-corrosion treatment
Durability
Construction
Non-treated fin
PE fin
Aluminium
AluminiumCorrosion resistantacrylic resin
Hydrophilic film
Allowed refrigerant piping length
and level difference
Max. lengthMax. level
difference
Pre charged1
30 m30 m71KU
30 m100HU
50 m(Equivalent length 70m)
30 m125HU
50 m(Equivalent length 70m)
50 m(Equivalent length 70m)
50 m(Equivalent length 70m)
30 m30 m
30 m
30 m
30 m125KU
30 m140KU
50 m(Equivalent length 70m)
50 m(Equivalent length 70m)
30 m
30 m
100KU
30 m140HU
Note :1Additional refrigerant charging is required if the
refrigerant pipe is longer than the length.
30 m 50 m(Equivalent length 70m)
8:00 12:00 16:00 20:00
Power
consumption
Time
Limitation
Demand Control Function
* Required for KRP58M51 (Option)
(Applicable to RZR100140KU, 100140HU outdoor units)
(Compared to RZQ100-160PV4A)
RZR100HUY1
RZR125HUY1RZR140HUY1
RZR71KUV1 RZR100KUV1
71KU
900 mm
320 mm
Suction
Discharge
900 mm
100KU100HU
125KU125HU
900 mm 900 mm
140KU140HU
-
8/9/2019 Daikin Skyair
19/40
-
8/9/2019 Daikin Skyair
20/40
Clear Display
LCD REMOTE CONTROLLER
Easy-to-read LCD remote controller allows vario
can control multiple indoor units.Remote controller options are shown on the page introducing each indoor unit model.
Necessary optional accessory
19
Navigation Remote Controller(Wired Remote Controller BRC1E61)
Clear display,
Simple operation,
"Navigation
Remote Controller"!This simple, modern designed remote
controller with fresh white colour matches
your interior design. Operation is much easier
and smoother, just follow the indications on
the navigation remote controller.
A combination of fine dots enables various iconsand texts to be displayed smoothly. Large text
display improves readability.
Equipped
backlight helps
operating in dark rooms.
The schedule timer for each
day of the week can be setup easily.
Display is available in 10
languages.(English, German, French, Spanish,
Italian, Portuguese, Greek, Dutch,
Russian and Turkish).
Dot matrix display
Backlight display
Other Features
Weekly schedule timer Multilingual display
Large buttons and arrows keysfor easy operation. Basic
settings such as fan speed and
temperature can be intuitively
operated. For other settings
just select the function from the
menu list.
The display gives an
explanation of each setting
for easy operation.
Simple operation
Large buttons and arrow keys
Guide on display
-
8/9/2019 Daikin Skyair
21/4020
s system control configurations and
Enables temperature sensing closer to targetarea for improved comfort. (When using remotecontrol from another room, temperature-sensor inindoor unit's air inlet must be selected.)
Facilitates maintenance and repair
All initial settings can be set from the remotecontroller. After interior construction is complete,
ceiling mounted cassette type can be remotelyset without having to use stepladder access formanual setting.Setting contents: High ceiling use, air direction, filter type, address
for centralised control (group control address is set automatically).
Remote controller is equipped with model nameand failure display functions. This facilitatesservice in the unlikely event of a malfunction.
SkyAir shares common control withHRV (heat reclaim ventilation) and
the other Daikin air-conditioningunits, thus simplifying interlockingoperations.
Easily adaptable to large-scale, high-function,centralised remote control systems.Installing and connecting control wiring betweenSkyAir and other Daikin air-conditioningequipment is easy.
LCD panel shows operating status in letters, numbers, and motion.
Airflow / swing display Displays auto-swing operating status and setting position of air discharge angle.
Preset temperature / operation mode display Displays preset room temperature and operating status (fan, dry, cool).
Programming time displayOperation start and stop time can be set for individual timers up to 72 hours. The LCD also shows
when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.
Self-diagnosis function Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.
Indoor units applicable for the remote controllerSignal receiver unit is contained inside decoration panel or indoor unit
CEILING MOUNTED CASSETTE TYPE
COMPACT MULTI FLOW TYPE
CEILING MOUNTED BUILT-IN TYPE
CEILING SUSPENDED TYPE
BRC7E531W
BRC7F632F
BRC4C62
DUCT CONNECTION MIDDLE HIGH STATIC PRESSURE TYPE BRC4C62
BRC7EA66
LCD wireless remote controller
Note: The signal receiver unit shown in the
photograph is for mounting inside
the decoration panel of the ceiling
mounted cassette type.Wireless remotecontroller
Light receptor mounted type
BRC7F632F
The wireless remote controller is
supplied in a set with a signal
receiver.
Shape of signal receiver unit
differs according to the indoor
unit.Signal receiver unit(For ceiling mountedcassette type)
Easier to read because LCD screen is larger.
Wired LCD remote controller
BRC1C61
For easier operation, louver switches, which
are frequently used, have been made larger.
Oil-resistant plastic casing.
Only 17 mm thick. Can be installed either
recessed or exposed.
Remote control is equipped with weekly timer function.
Wired LCD remote controller with weekly schedule timer
BRC1D61
24-hour clock function.
Programming function for each day of week.
Scheduling possible of start/stop and
temperature limit (5 settings/day).
Wired remote controller hasbuilt-in temperature-sensor(Applies to wired remote controllers (BRC1D61,BRC1E61))
(Applies to wired remote controller (BRC1E61))
-
8/9/2019 Daikin Skyair
22/40
LCD REMOTE CONTROLLER
Central remote controller
Interface adaptor for SkyAir series
Easily adaptable to large-scale, high-function, centralised remote control system.
Centralised control, with setting assimple as it is with a standard
remote controller, of up to 64 groups(1,024 indoor units) is possible.
DCS302CA61(Option)
DTA112BA51(Option)
With its high functionality, the fullcolour all-in-one graphic controller
facilitates management of SkyAirSystem in a variety of ways.
DCS601C51(Option)
Unified on/off controller
Centralised control of on/off bygroup or all at once for up to 256
indoor units.
DCS301BA61(Option)
Schedule timer
Unified control of weekly schedulefor up to 1,024 indoor units.
DST301BA61(Option)
Schedule timer sets on/off time in 1 minute unitsto be executed twice a day for a week at a time.
*Please refer to the page 29 for the details.
Simple system provides a diverse assortment of control modes.
Control by 1remote controller
Control pattern Wired remote controller Wireless remote controller
Control by 2remote controllers
Group control
Control byexternal command
Centralised remotecontrol
Interlock controlwith HRV
(Basic system)
Link by remotecontroller group control.
Zone link control bycentralised control.
For control from 2locations such as inroom and control room,exits, etc.
For simultaneouscontrol of up to 16indoor units.
Centralised control ofup to 64 indoor groupsfrom remote locationup to 1 kilometer away.
Control by 1 wireless remotecontroller and 1 wired remotecontroller (See note 1)
Signal receiver unit installedon indoor unit
Signal receiver unit installedon indoor unit
HRV for indoor units within a zone are operated by interlockingCan also be operated independently by remote controller.
Central remote controller (option)
HRV
Can be operated simultaneouslyor independently by remote controller(set by ventilation mode)
HRV
Central remote controller (option)
Non-polar, double-core(max. wiring length 500 m)
Connects 2 wiredremote controllers
Automatic address setting function Automatic address setting function
Signal receiver unit installedon 1 indoor unit
Optional wiring adaptor for
electrical appendices is necessary
Central remote controller (option)
Can be operated simultaneouslyby remote controller(set by ventilation mode)
HRV
HRV for indoor units within a zone are operatedby interlocking
Central remote controller (option)
HRV
Operation andsurveillance is carried out
using the contact signalfrom the operation controlbox in the buildingsurveillance (security)room.
Optional wiring adaptor for
electrical appendices is necessary
Optional SkyAir series interfaceadaptor required. 1
Optional SkyAir series interfaceadaptor required. 1
Note: When a wireless remote controller is used, remote control by two remote controllers is not possible.1
The ceiling mounted cassette type come standard with an interface adaptor for SkyAir series (DTA112BA51).
Enables centralised control via connectionto a high-speed, DIII-NET communicationsystem, adopted for the Daikin VRV system.Necessary for interface adaptor for SkyAir series with the
central remote control units shown at above.
The interface adaptor for the Skyair series isoptional except for the ceiling mounted cassettetype.
21
-
8/9/2019 Daikin Skyair
23/4022
Use the temperature-sensor in theindoor unit when controlling airconditioning from another room.
Temperature-sensors are included in the indoor unit andoptional wired remote controller. Temperature sensingcloser to target area is possibleto further increase the comfortlevel.
Note: Wireless remote controllers have notemperature-sensor.
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acrylpretreatment) are used for the heat exchanger of the outdoor unit.In high corrosive areas, regular maintenance needs to be carried out.
Abundance of functions that provide comfortable
air-conditioning in stores and offices.Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.
PE fin
O t h e r s
Air discharge direction angle canbe set (fixed setting)
Dehumidification is microprocessor controlled to preventabrupt and uncomfortable changes in air temperature. Usefulfor reducing uncomfortable humidity without uncomfortablecooling of the room.
Sanitary filter has mould-resistant treatment. Mould-proofing maintains hygiene by preventing growth inhighly humid conditions.
Delivers comfortable air-conditioning to all areas,near to and far from the air-conditioner.
High setting provides maximum reach while low settingminimises drafts.
Auto-swing
Programme "Dry" with a humidity sensor
Mould-resistant treatment for filter Mould-proofing drain pan
Switchable fan speed
(1) Air direction instandard position
(2) Air direction in ceilingsoiling preventionposition
(standard, ceiling soiling prevention) Note:When units are installed on high ceilings, depending on the model, various restrictions
concerning maximum height, air discharge direction, and choice of options may apply.You can freely set 2 air discharge positions by remote controller.
Swing pattern selection
Delivers air-conditioning comfort all the way down to the floorin air-conditioning zones with high ceilings.
High-ceiling application
Efficient cooling even in winter when indoor temperatures arehigher than those outside, such as in underground publicspaces or offices with many computers.
The year-round cooling kit is required as option.
Year-round cooling applicable
Operation starts when the preset time of the ON timer elapsesand stops when the preset time of the OFF timer elapses.
Timer selector
Two selectable temperature-sensors
C o m f o r t
Mould prevention
*available on all models.
*available on all models.
*available on all models.
-
8/9/2019 Daikin Skyair
24/40
If there is a malfunction elsewhere in the system, the fan orcompressor can still be operated.
Insufficient gas charging is normally hard to detect. Duringpost-installation trials and regular inspection procedures, therefrigerant level is monitored by microprocessor to maintainproper gas pressure. Reliability is assured and maintenanceand inspection can be carried out more quickly.
You can turn up to 16 indoor units on/off with a single remotecontroller. (When using connected indoor units, the settingsmust all be the same and on/off will be simultaneous.)
Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.
Emergency operation
Low gas pressure detection
Control by 1 remote controller
Operation and surveillance is carried out using the contact
signal from the operation control box in the buildingsurveillance (security) room.
External command control
Optional central remote controller enables centralised controlof up to 1024 indoor units (64 groups) from up to 1 kilometeraway.
Central remote control
Enables interlocking control with external equipment such asheat reclaim ventilation (HRV).
Interlock control
The operating parameters of indoor and outdoor units, andsensor data at critical locations throughout the system, areconstantly monitored using a microcomputer. To facilitatequick response in the event of a malfunction, a messageappears on the LCD of the remote controller and an LED onthe unit illuminates.
Self diagnosis function
Two types are available: 65% and 90% colorimetry.
High-efficiency filter unit
You can provide air-conditioning with fresh air from outside.Convenient for places where a ventilation fan cannot beinstalled.
Fresh-air intake kit
Work and Servicing
Control features
Options
Steeper gradient realises moreefficient condensate drainage.High-lift is especially useful forlong lengths of drain piping.
Maintenance is not required for one year (two years when aceiling mounted cassette type is used).
If refrigerant piping length does not exceed 30 m, there is noneed for on-site gas charging.
The filter sign warns you when it is time to clean the filter.
*When using a wired remote controller the sign is displayed in the LCD. When using a
wireless remote controller the filter sign lamp illuminates on the signal receiver unit.
Drain pump mechanism
Long-life filter
Pre charged for up to 30 metres
Filter sign
Daikin's innovative air discharge mechanism keeps airflowaway from the ceiling. Ceiling cleaning is less frequentlyrequired.
Ceiling soiling prevention function
If there is a power outage while the equipment is operating,
operations will restart in the same mode as before the powercut when electricity is restored.
Ultra long-life filter
Auto-restart
Using 2 remote controllers you can operate the equipmentlocally or from a remote location.
Note: When a wireless remote controller is used, remote control by two remote controllers is
not possible.
Control by 2 remote controllers
RXS50FA/60F/71F, RKS25A/35A/50A/60A : 10 m
*Applicable to RZR71-140KU, RZR100-140HU.
Requires no maintenance for about 4 years* (10,000h) instores and offices.
*For dust concentration of 0.15 mg/m3
*Required for KRP58M51 (Option)
*available on all models.
*available on all models.
*Connecting ducts, insect nets, fire dampers, air filters, and other partsshould, as required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary. OptionalPCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced through the kit
is limited to 10% of the maximum airflow rate of the indoor unit. Introducinghigher quantities will increase the operating noise and may also influencetemperature sending.
Note:
23
-
8/9/2019 Daikin Skyair
25/40
-
8/9/2019 Daikin Skyair
26/40
CEILING SUSPENDED TYPE
Note :1Rated cooling capacities are based on the following conditions: Indoor temp., 27CDB, 19.0CWB; outdoor temp. 35CDB Equiv. refrigeration piping, 7.5 m (horizontal).
2Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
35 50 60
1 Phase, 220240 V, 50 Hz 1 Phase, 200240 V, 50 Hz
37/32
195X960X680
24
38/33
195X960X680
25
39/33
195X1,160X680
27
5.0(1.7-5.6)
5.7(1.7-6.0)
1.72 2.00
3.4(1.2-3.7)
1.05
White
14 to 28
1.1 1.1
1.5 (Charged for 10 m)
VP20 (I.Do/20XO.Do/26) VP20 (External dia.26,internal dia.20)
47 49
735X825X300 735X825X300
47
10 to 46
47
o/6.4
o/12.7
30 30
o/6.4
o/12.7
20
47
550X765X285
34
1.0 (Charged for 10 m)
0.6
Ivory white
20
15
Hermetically sealed swing type
o/6.4
o/9.5
o/18.0 (Hole) o/18.0 (Hole) o/18.0 (Hole)
CWB
kW
kWPower consumption
CDBCertified operation range
Certified operation range
Motor output
Compressor
Model
Name
Indoor unit
Outdoor unit
Dimensions (HXWXD)
Colour
mm
dB(A)
kW
Refrigerant charge (R-410A) kg
dB(A)Sound level2
Dimensions (HXWXD) mm
Machine weight kg
Piping
connections
mmLiquid (Flare)
mmGas (Flare)
mmDrain Indoor unit
Outdoor unit
Machine weight kg
Airflow rate (H) m3/min 13/10 17/1313/10458/353 600/458458/353
Outdoor
unit
Colour
mm
Heat insulation
Max. interunit piping length m
mMax. installation level difference
Power supply
Type
Sound level (H/L)2
Indoorunit
FHQ35BVV1B FHQ50BVV1B
RKS35AVMG RKS50AVMG
FHQ60BVV1B
RKS60AVMG
Both liquid and gas piping
Cooling capacity1
Rated (Min. - Max.)
cfm
71 100 125
FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B
RZR71KUV1 RZR100KUV1 RZR125KUV1
39/35 42/37 44/39
195X1,160X680 195X1,400X680 195X1,590X680
o/9.5
o/15.9
770X900X320
61
o/9.5 o/9.5
o/15.9 o/15.9
1,170X900X320 1,170X900X320
92 97
32
-5 to 46
14 to 28
35
Hermetically sealed scroll type
27
30
48 49 50
50 (Equivalent length 70)o/26.0 (Hole)
1.7
1.75 (Charged for 30 m)
17/14 24/20 30/25600/494 847/706 1,059/883
10.0(5.0-11.2)
12.5(5.7-14.0)
o/26.0 (Hole) o/26.0 (Hole)
2.1 2.6
2.4 (Charged for 30 m) 3.7 (Charged for 30 m)
3.51 4.552.50
7.1(3.2-8.0)
CEILING SUSPENDED TYPE
3 Phase, 380415 V, 50 Hz
VP20 (External dia.26,internal dia.20)
Ivory white
CWB
kW
kWPower consumption
CDBCertified operation range
Certified operation range
Motor output
Compressor
Model
Name
Indoor unit
Outdoor unit
Dimensions (HXWXD)
Colour
mm
dB(A)
kW
Refrigerant charge (R-410A) kg
dB(A)Sound level2
Dimensions (HXWXD) mm
Machine weight kg
Pipingconnections
mmLiquid (Flare)mmGas (Flare)
mmDrain Indoor unit
Outdoor unit
Machine weight kg
Airflow rate (H/L) m3/min
Outdoor
unit
Colour
mm
Heat insulation
Max. interunit piping length m
mMax. installation level difference
Power supply
Type
Sound level (H/L)2
Indoor
unit
Both liquid and gas piping
Cooling capacity1
Rated (Min. - Max.)
cfm
100 125
FHQ100BVV1B FHQ125BVV1B
RZR100HUY1 RZR125HUY1
42/37 44/39
195X1,400X680 195X1,590X680
o/9.5 o/9.5o/15.9 o/15.9
1,345X900X320 1,345X900X320
94 104
32 35
Hermetically sealed scroll type
30
49 50
50 (Equivalent length 70)
24/20 30/25
847/706 1,059/883
10.0
(5.0-11.2)
12.5
(5.7-14.0)
o/26.0 (Hole) o/26.0 (Hole)
2.1 2.6
3.9 (Charged for 30 m) 4.3 (Charged for 30 m)
White
3.51 4.55
14 to 28
-5 to 46
25
SPECIFICATIONS
-
8/9/2019 Daikin Skyair
27/4026
1 Phase, 220240 V, 50 HzPower supply
6050 71
CEILING MOUNTED BUILT-IN TYPE
Model
Name
Indoor unit
Outdoor unit
kW
FBQ50BV1A
RXS50FAVMA
FBQ60BV1A
RXS60FVMA
FBQ71BV1A
RXS71FVMA
5.0(1.7-5.6)
CDBCooling
CWBCooling
Cooling
Cooling
Certified Operation range
Certified Operation range
Motor outputCompressor
Indoor
unit
Dimensions (HXWXD)
Colour
mm
dB(A)
kWRefrigerant charge (R-410A)
Sound level3
Cooling (H/L)Sound level3
dB(A)
Dimensions (HXWXD) mmMachine weight kg
Pipingconnections
mmLiquidmmGasmmDrain Indoor unit
Machine weight kg
kg
Airflow rate(H/L)
Fan
Outdoorunit
Colour
Heat insulation
Max. interunit piping length mmMax. installation level difference
Type
300X700X800
34
33/29
47
735X825X300 735X825X300 770X900X320
48
----------
o/6.4
o/12.7
o/6.4
o/12.7
o/6.4
o/15.9
o/18.0 o/18.0
10 to 46
3020
Both liquid and gas piping
VP25 (I.Do/25XO.Do/32)
mmOutdoor unit
Ivory white
Hermetically sealed swing type
1.1
1.5 (Charged for 10 m)
kWCoolingPower consumption 1.98
5.7(1.7-7.0)
300X1000X800
Pa 88-49-20 88-49-20
41
14 to 28
34/30
49
48
1.1
1.5 (Charged for 10 m)
2.23
6.7(2.3-8.0)
300X1000X800
88-49-20
41
34/30
cfm 459/318 636/459 636/459
52
Night quiet mode dB(A) ---------- ---------- ----------
71
1.92
2.3 (Charged for 10 m)
2.57
External static pressure2
(High-Standard-Low)
o/18.0
Cooling capacity1
Rated (Min. - Max.)
m3/min 13/9 18/13 18/13
1 Phase, 220240 V, 50 Hz 3 Phase, 380415 V, 50 HzPower supply
10071 125
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
Note :1(FBQ50B-71B) :Rated cooling capacities are based on the following conditions: Suction temp., 27CDB, 19.0CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal) (FBQ100B-125B):Rated cooling capacities are based on the following conditions: Suction temp., 27CDB, 19.0CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 5 m (horizontal) (FBQ71D-140D) :Rated cooling capacities are based on the following conditions: Suction temp., 27CDB, 19.0CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal)2Initial setting is standard.3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.4In case of drain piping for outdoor unit, drain piping kit (option) is needed.
Model
Name
Indoor unit
Outdoor unit
kW
FBQ71DV1
RZR71KUV1
FBQ100DV1
RZR100KUV1
FBQ125DV1
RZR125KUV1
7.1
(3.2-8.0)
CDBCooling
CWBCooling
Cooling
Cooling
Certified Operation range
Certified Operation range
Motor output
Compressor
Indoorunit
Dimensions (HXWXD)
Colour
mm
dB(A)
kWRefrigerant charge (R-410A)
Sound level3
Cooling (H/L)Sound level3
dB(A)
Dimensions (HXWXD) mm
Machine weight kg
Pipingconnections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Machine weight kg
kg
Airflow rate(H/L)
Fan
Outdoorunit
Colour
Heat insulation
Max. interunit piping length m
mMax. installation level difference
Type
300X1,000X700
36
770X900X320 1,170X900X320 1,170X900X320
61
----------
o/9.5
o/15.9
o/9.5
o/15.9
o/9.5
o/15.9
o/26 (Hole) o/26 (Hole)
50 (Equivalent length 70)
Both liquid and gas piping
I.Do/25XO.Do/32
mmOutdoor unit4
Ivory white
Hermetically sealedswing type
1.5
1.75 (Charged for30 m)
kWCoolingPower consumption
10.0
(5.0-11.2)
300X1,400X700
Pa
46
92
1.8
2.4 (Charged for 30 m)
12.5
(5.7-14.0)
300X1,400X700
46
cfm 635/530 1,130/812 1,377/988
Night quiet mode dB(A)
97
2.4
3.7 (Charged for 10 m)
External static pressure2
(High-Standard-Low)
o/26 (Hole)
Cooling capacity1
Rated (Min. - Max.)
100 125
FBQ100DV1
RZR100HUY1
FBQ125DV1
RZR125HUY1
140
FBQ140DV1
RZR140HUY1
10.0
(5.0-11.2)
46
1,130/812
12.5
(5.7-14.0)
1,170X900X320
o/9.5
o/15.9
o/9.5
o/15.9
o/9.5
o/15.9
30
Hermetically sealed scroll type
300X1,400X700 300X1,400X700
46
300X1,400X700
97
-5 to 46
1,345X900X320
94
2.9 1.6
3.7 (Charged for 30 m) 3.9 (Charged for 30 m)
1,345X900X320
104
2.3
4.3 (Charged for 30 m)
140
FBQ140DV1
RZR140KUV1
14.0
(6.25-15.4)
46
14 to 28
1,377/988
m3/min 18/15 32/23 39/28 32/23
1,377/988
39/2839/28
o/26 (Hole) o/26 (Hole) o/26 (Hole)
14.0
(6.25-15.4)2.22 3.13 3.97 3.13 3.974.75 4.75
o/9.5
o/15.9
46
37/32 38/33 40/36 38/33 40/3640/36 40/36
300X1,400X700
1,345X900X320
104
2.8
4.3 (Charged for 30 m)
48 49 50 49 5050
46
50
1,377/988
39/28
o/26 (Hole)
NA
47 49 45 49 45 46
-
8/9/2019 Daikin Skyair
28/40
Indoor unit
Touch Controller4 DCS601C51
Note: 1Refer to page 8 for the details.2Required for installing high-efficiency filter or ultra long-life filter.3Wiring for wired remote controller to be procured locally.
CEILING MOUNTED CASSETTE TYPEKit name
DCS302CA61
BRC1E61
DCS301BA61
DST301BA61
KRP1C63
KDDFP55H160
KDBH55K160F
KDBP55H160FA
KKSJ55K160
KDDP55K160
KDDP55K160K
KDDP55X160
KRP4AA53
KAFP551K160
KAFP556H80
KAFP557H80
KAFP552H80
KDTP55K80
KDJP55H160KDJP55H80
BRC7F632F
BRC1D61
KAFP553H80
KDTP55K160
KAFP556H160
KAFP557H160
KAFP552H160
KAFP553H160
BYCP125K-W1
KRP1H98
KAFP55H160
KAFP55H160H
FCQ71KVEA FCQ100KVEA FCQ125KVEA FCQ140KVEAName of option Remark
Chambertype
Decoration panel
Fresh airintake kit1
Central remote controller4
Unified ON/OFF controller4
Schedule timer4
Adaptor for wiring5
Without the T-joint pipe and fan
With the T-joint pipe, without fan
Direct installation type
Sealing member of air discharge outlet
Panel spacer
Chamber connection kit2
Insulation kit for high humidity
Group control adaptor5
Installation box for adaptor PCB
High-efficiency filter
Filter chamber
Long-life filter
Ultra long-life filter
Replacement ultra long-life filter
(Colorimetric method 65%)
(Colorimetric method 90%)
Replacementhigh-efficiency filter
(Colorimetric method 65%)
(Colorimetric method 90%)
Remote controller
Navigation Remote Controller
Wireless type
Wired type3
Branch duct chamber
Wired LCD remote controller with weekly schedule timer
For each flow pattern all round, 4-way, 3-way, 2-way, branch duct connection the compatibility of each independently installed option(shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect.A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation.
Round flow type: List of optional parts required to achieve different flow patterns
4The indoor unit is equipped standardly with the interface for SkyAir series and an option is unnecessary.5Installation box for adaptor PCB (KRP1H98) is necessary.
1In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to checkwhether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable.
2Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position.3It is not possible to use panel spacers in a 2-way flow installation.
4
It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed.
Panel/grille related
Independently installable optional parts
Operation control related
Auxillary function related
Filter related
Optional accessory parts
Independently installable optional partsOptional accessory parts
Independently installable optional partsOptional accessory parts
Panel spacer1
Panel spacer1 o o ox o
Wireless remote controller o o oo o
Fresh air intake kit (direct mount) o o oo o
x o o
x
x
High-efficiency filter2
Filter related Ultra-long-life filter2
o o o
x
x
Ultra-long-life filter2 o o o xx
High-humidity operation kit
Panel/grille related
Operation control related
Auxillary function related
Panel spacer1
Wireless remote controller
Fresh air intake kit (direct mount)
High-humidity operation kit
All round flow 4-way flow
o3 o3 xx o3
o3 o
x
x
xo o
o3 o x
x
o o
x o o x
o3 o o xx
3-way flow 2-way flow
1-way branch / unit 3-way flowBranch duct1
(Chamber type)
(Round duct type)
o o o4 xx o
2-way branch / unit 2-way flow
1-way branch / unit 2-way flow
x o o4 xx o
x o o4 xx o
Branch duct connection
Wirelessremote controller
Fresh air intake kit(direct mount)
High-efficiencyfilter2
High-humidityoperation kit
Ultra-long-lifefilter2
Panel spacer1Wireless
remote controllerFresh air intake kit
(direct mount)High-efficiency
filter2
High-humidity
operation kit
Ultra-long-life
filter2
Panel spacer1Wireless
remote controllerFresh air intake kit
(direct mount)
Fresh air intake kit (Chamber type)1,2 o o ox o
Fresh air intake kit (Chamber type)1,2 o3 o xx o
o
o
x
o
o
o3
o
x
x
x
o
o
o
o
Fresh air intake kit(Chamber type)1,2
Fresh air intake kit(Chamber type)1,2
Fresh air intake kit(Chamber type)1,2
High-efficiencyfilter2
High-humidityoperation kit
Ultra-long-lifefilter2
Remote sensor (for indoor temperature) KRCS01-4B
OPTIONS
27
-
8/9/2019 Daikin Skyair
29/40
28
----------
----------
----------
Touch Controller2
Indoor unit
Kit nameName of option
FHQ35BVV1B FHQ50BVV1B FHQ60BVV1B
BRC7E531W
BRC7EA66
DCS302CA61
DCS301BA61
DST301BA61
KRP1BA54
KHFP5MA63KHFP5MA35
KAF501DA80KAF501DA56
KDU50N60VE
Remark
Kit nameName of option Remark
Touch Controller3
DCS601C51
Note:
Replacement long-life filter
L-type piping kit (for upward direction)
Drain-up kit
Remote controller
Resin net
Wireless type
Central remote controller2
Unified ON/OFF controller2
Schedule timer2
Adaptor for wiring
Wiring adaptor for electrical appendices3
Interface adaptor for SkyAir series
Installation box for adaptor PCB
FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1B
Decoration panel
Fresh air intake kit
Central remote controller3
Unified ON/OFF controller3
Schedule timer3
Adaptor for wiring2
Direct installation type
Wiring adaptor for electrical appendices2
Sealing member for air discharge outlet
Panel spacer
Interface adaptor for SkyAir series
Installation box for adaptor PCB
Replacement long-life filter
Remote sensor (for indoor temperature)
DCS302CA61
DCS301BA61
DCS601C51
DST301BA61
KRP1BA57KRP4AA53
KRCS01-1B
BYFQ60B8W1
Wired LCD remote controller with weekly schedule timer BRC1D61
Wired LCD remote controller with weekly schedule timer BRC1D61
Wired LCD remote controller with weekly schedule timer BRC1D61
KDBHQ44B60
KDBQ44B60
KDDQ44X60
DTA112BA51
KRP1BA101
KAFQ441B60
Note: 1Wiring for wired remote controller to be procured locally. 2Installation box for adaptor PCB (KRP1BA101) is necessary. 3This optional accessory requires DTA112BA51.
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
CEILING SUSPENDED TYPE
1Wiring for wired remote controller to be procured locally.2This optional accessory requires DTA112BA51.3Installation box for adaptor PCB (KRP1CA93) is necessary.
Remote controller Wireless type Cooling only
FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B
KRP4AA52
DTA112BA51
KRP1CA93
KHFP5MA160
KAF501DA112 KAF501DA160
KDU50N125VE
KRCS01-1B
KJB311AA
KJB212AA
Remote sensor (for indoor temperature)
Electrical box with earth terminal (3 blocks)
Electrical box with earth terminal (2 blocks)
BRC1E61Navigation Remote Controller Wired type1
BRC1E61Navigation Remote Controller Wired type1
FBQ50BV1A
KTBJ25K56W KTBJ25K80W
KDAJ25K56A KDAJ25K71A
FBQ60BV1A FBQ71BV1A
CEILING MOUNTED BUILT-IN TYPE
Service access panel
Air discharge adaptor
Adaptor for wiring (interlock for fresh air intake fan)
Group control adapter
Interface adaptor for SkyAir series
Remote controller Wireless type
Kit nameName of option Remark
Central remote controller2
Unified ON/OFF controller2
Schedule timer2
Note:1Wiring for wired remote controller to be procured locally.
2This optional accessory requires DTA112BA51.
Touch Controller2
KRP4AA51
KRP1BA54
DTA112BA51
BRC4C62
DCS301BA61
DCS302CA61
DST301BA61
DCS601C51
BRC1E61Navigation Remote Controller Wired type1
-
8/9/2019 Daikin Skyair
30/40
-
8/9/2019 Daikin Skyair
31/40
DIMENSIONS
CEILING MOUNTED CASSETTE TYPE
(Unit: mm)
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Power-source wiring and a unit wiring connection
Connection wiring / remote control wiring connection
Air-outlet
Suction grille
Corner decoration cover
Drain hose (accessory)
1
2
3
4
5
6
7
8
9
Notes:1Sticking location for manufacture's labelmanufacture's label for indoor unit:Suction grille inner side's electric components box's lid surface
manufacture's label for decoration panel :Decoration panel's corner decoration cover inner surface2In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controllerin detail.
3When the temperature and humidity in the ceiling exceed 30 C and RH 80% or the fresh air is inducted into the ceiling or the unitcontinues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required.
4Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or lessbetween the indoor unit and the ceiling opening so that
the panel overlap allowance can be ensured.5Please do not place the thing been damp and troubled under an indoor unit.When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
30
[FCQ71KVEA]
[FCQ71KVEA]
[FCQ100-140KVEA]
[FCQ71KVEA] [FCQ71KVEA]
[FCQ100-140KVEA]
[FCQ71-140KVEA] [FCQ71-140KVEA]
[FCQ100-140KVEA]
[FCQ100-140KVEA]
-
8/9/2019 Daikin Skyair
32/40
-
8/9/2019 Daikin Skyair
33/4032
CEILING MOUNTED BUILT-IN TYPE
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
856
Liquid pipe connectionGas pipe connection
Drain pipe connection
Interunit wiring port
Power wiring port
Drain hole
Discharge flange
suction flange
Switch box
Inspection hole
12
3
4
Notes:1Location of unit's Name Plate: Fan hosing surface.2If the ceiling is not removable, a 300 mm service spacemust be kept between the unit and the ceiling.3Mount the air filter at the suction side.(Select its colorimethod (Gravity method) 50 % or more)
5
6
7
8
9
10
A B C D G
833 6X120=720 1000 785FBQ60BV1A/71BV1A
556 533 4X120=480
F
5X150=750
3X150=450
H
11X65=715
6X65=390
I
12X65=780
7X65=455700
E
760
460 485
J
1050
750FBQ50BV1A
[FBQ50BV1A, FBQ60BV1A, FBQ71BV1A]
[FBQ71DV1]
According to any one of below 1)~3),secure a space for service works,such as,checking and maintenance of control box,etc.
1)One inspection hatch (450X450) on the control box side and a space of 300mm or more under the unit.(Fig.A)2)One inspection hatch (450X450) on the control box side and 2 (two) inspection hatches under the unit.(Arrow View B-1)3)3 (three) inspection hatches under the unit and the control box.(Arrow View B-2)
Notes:1Location of MANUFACTURE'S LABEL: Contro box surface2Mount the air filter at the suction side. (Select its colorimethod (gravity method) 50% or more.)3Do not locate things should not be wet under the indoor unit. Dews may drop when humidity reaches over 80%,or a drain gets stuck,or air filters are not clean.4Space for Service Works
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Ground terminal
(Terminal in Control box)
Control box(Inside)Remote control wiring
connection
Power-source wiring and
a unit wiring connection
Air discharge flange
Air suction flange
Hook
1
2
3
4
56
7
8
9
10
-
8/9/2019 Daikin Skyair
34/4033
DIMENSIONS (Unit: mm)
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
[FBQ100DV1, 125DV1, 140DV1]
According to any one of below 1)~3),secure a space for service works,such as,checking and maintenance of control box,etc.
1)One inspection hatch (450X450) on the control box side and a space of 300mm or more under the unit.(Fig.A)2)One inspection hatch (450X450) on the control box side and 2 (two) inspection hatches under the unit.(Arrow View B-1)3)3 (three) inspection hatches under the unit and the control box.(Arrow View B-2)
Notes:1Location of MANUFACTURE'S LABEL: Control box surface2Mount the air filter at the suction side.(Select its colorimethod (gravity method) 50% or more.3Do not locate things should not be wet under the indoor unit.Dews may drop when humidity reaches over 80%,or a drain gets stuck,or air filters are not clean.4Space for Service Works
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Ground terminal
(Terminal in Control box)
Control box(Inside)
Remote control wiring
connection
Power-source wiring and
a unit wiring connection
Air discharge flange
Air suction flange
Hook
1
2
3
4
5
6
7
8
9
10
-
8/9/2019 Daikin Skyair
35/4034
OUTDOOR UNIT // RKS25AVMG, RKS35AVMG
OUTDOOR UNIT // RKS50AVMG, RKS60AVMG, RXS50FAVMA, RXS60FVMA
-
8/9/2019 Daikin Skyair
36/40
-
8/9/2019 Daikin Skyair
37/40
-
8/9/2019 Daikin Skyair
38/4037
DIMENSIONS (Unit: mm)
REMOTE CONTROLLER
CEILING MOUNTED CASSETTE TYPE
CEILING SUSPENDED TYPE
CEILING MOUNTED BUILT-IN TYPE
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
BRC1E61
BRC1D61 / BRC1C61
-
8/9/2019 Daikin Skyair
39/4038
Installation service space for outdoor unit
1000
ormo
re
200(30
0)
ormore
LH
L H
H
L
500
ormo
re
50(100)
ormore
L H
For RZR71-140KUV1, RZR100-140HUY1
200(30
0)or
more
1000ormore
200ormore
100o
rmore
100ormore100o
rmore
50(100)o
rmore
1000
ormore
500o
rmore
When there is an obstruction on the inlet side
When the obstruction on the outlet side is higher than
the unit itself (There is no limit to the height of the
obstruction on the outlet side.)
When there are obstructions on both
the inlet and outlet sides
When there is an obstruction on the outlet side
When there are obstructions
on the inlet side and
both lateral sides
2. For series installation(more than two units)
When there are
obstructions on
both sides
When the overhead space is open
1. For single unit installation
When there is an
obstruction only
on the inlet side
When there is an obstruction
in the overhead space
When the overhead space is open
When there are obstructions
on both sides
When there is an obstructionin the overhead space
When there is an
obstruction on the
inlet side
When there are obstructions
on the inlet side and
both lateral sidesPattern 1
2. For series installation (more than two units)
1. For single unit installation
1. For single unit installation
When the overhead space is open
2. For series installation(more than two units)
1. For single unit installation
2. For series installation (more than two units)
1. For single unit installation
2. For series installation (more than two units)
100
ormore
500o
rless
1000ormore
An obstructionin the overheadspace
500o
rless
500o
rmore
1000ormore
An obstructionin the overhead space
500o
rless
1000
ormore
1000ormore
An obstructionin the overhead space
150
ormore
150ormore150ormore
500o
rless
1000ormore
An obstructionin the overheadspace
200(30
0)
ormore
1000ormore
200ormore
500o
rless
1000ormore
An obstructionin the overheadspace
(The unit values is mm. )
The values represent the case for the RZR71-140KUV1 type. The values in ( ) are for RZR100 - RZR140HUY1 type.
-
8/9/2019 Daikin Skyair
40/40
DealerHead Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.
Cautions on product corrosion
Warning Daikin Industries, Ltd.s products are manufactured for export to numerous countries throughout the
world. Daikin Industries, Ltd. does not have control over which products are exported to and used in a
particular country. Prior to purchase, please therefore confirm with your local authorised importer,
distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for
use, in the region where the product will be used. This statement does not purport to exclude, restrict
or modify the application of any local legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
JMI-0107 JQA-1452
Organization:DAIKIN INDUSTRIES, LTD.AIR CONDITIONING MANUFACTURING DIVISION
Scope of Registration:THE DESIGN/DEVELOPMENT AND MANUFACTURE OFCOMMERCIAL AIR CONDITIONING, HEATING, COOLING,REFRIGERATING EQUIPMENT, COMMERCIAL HEATINGEQUIPMENT, RESIDENTIAL AIR CONDITIONINGEQUIPMENT, HEAT RECLAIM VENTILATION, AIRCLEANING EQUIPMENT, MARINE TYPE CONTAINERREFRIGERATION UNITS, COMPRESSORS AND VALVES.
Organization:DAIKIN INDUSTRIES(THAILAND) LTD.
Scope of Registration:THE DESIGN/DEVELOPMENTAND MANUFACTURE OF AIRCONDITIONERS AND THECOMPONENTS INCLUDINGCOMPRESSORS USED FOR THEM
All of the Daikin Groups businessfacilities and subsidiaries in Japanare certified under the ISO 14001international standard forenvironment management.