Daikin SkyAir (Inverter) Catalogue r3 · 2020. 3. 5. · 2.03 1.9 (Charged for 30 m) 1.9 32/26/20...
Transcript of Daikin SkyAir (Inverter) Catalogue r3 · 2020. 3. 5. · 2.03 1.9 (Charged for 30 m) 1.9 32/26/20...
-
PCASSG1601C
-
2 3
P r o d u c t L i n e u p 1 phase 3 phase
OUTDOOR UNIT
RZR50LVVM RZR60LVVM RZR71LVVMG RZR100MVMG
NEW NEWOutdoor unit
ENERGY SAVING LABEL
RZR125MVMGNEW
RZR125MYMNEW
RZR140MYM
71 100 12550
Pai
r
Product
RZR50LVVM RZR71LVVMGRZR100MVMG RZR125MVMG RZR125MYM RZR140MYM
RZR100MYM
RZR71LVVMGRZR100MVMG RZR125MVMGRZR100MYM RZR125MYM RZR140MYM
Series
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
140
FCQ50LUV1 FCQ71LUV1 FCQ100KAVEA FCQ140KAVEA
RZR50LVVM
NEW NEWFBQ71EVEFBQ50EVE
NEW
FAQ100CVEA
NEW
NEW NEW
NEW NEW NEW NEW NEW
FBQ140EVENEW
NEW
RZR100MYMNEW NEW NEW NEW
NEW
RZR100MYM RZR140MYMOutdoor unit
RZR125MYMNEW
NEW
NEW
Indoor unit
60
RZR60LVVM
RZR60LVVM
FCQ60LUV1
NEWFBQ60EVE
FHQ100DAVMANEW
FHQ125DAVMANEW
NEW
NEW
FHQ140DAVMA
CEILING MOUNTED CASSETTE TYPE
Round Flow
CEILING SUSPENDED TYPE
DUCT CONNECTION MIDDLE
and HIGH STATIC PRESSURE TYPE
WALL MOUNTED TYPE
Page 10
Page 12
Page 14
Page 16
FCQ125KAVEA
FBQ125EVEFBQ100EVE
NEWRZR100MYM
222222 333333
-
OPTIONAL
-
Outdoor unit operating sound can be reducedby 4dB(A).
-
Airflow distribution
Creates uniform comfort throughout
the space
Comfort Enhanced by Round Flow!
With uniform temperature distribution Enhanced Comfort
Greater comfortImproved energy saving
Treated surface
Untreated surface
Grimy surface
Resists soiling
Adapts Easily to The InstallationSpace.
Easy Cleaning with Coated External Panels.
L-shaped 2-way flow
(E.g., installed in a corner)
Opposite 2-way flow
(E.g., installed in a long room)
3-way flow
(E.g., installed near a wall)
(E.g., installed in middle of ceiling)
4-way flow also possible.
All-round flow
360° airflow can maintain comfort even if air discharge speed is lower.
Typical flow patterns
There are a total of 23 flow patterns.
If you raise the set temperature by 1 to 1.5°C,and velocity is decreased by 25%, you still obtain the same feeling temperature and comfort.
Quiet Operation at 28** dB(A)
Because air flows out from corner outlets, comfort spreads more widely.
Silver ion anti-bacterial drain panNon-flocking flapsFilter has anti-mould and antibacterialtreatment
• Condition after exposure to the smoke of 600 cigarettes in 1 m3 enclosed space.
Optimal Comfort and Convenience Assured by 2 Air Discharge Modes
Air direction
Auto air direction control
Recommended for shops with light coloured ceilings that
must be kept spotless.
Standard position to prevent draft.
Standard setting1Setting to prevent soiling
of ceiling2 (field setting)
Desired situation
Auto-swing
5-levelsair directionsetting
Settable to 5 different levels between 25° and 60°
Settable to 5 different levels between 15° and 60°
Auto-swing between15° and 60°
Auto-swing between25° and 60°
The air direction is set automatically to the memorisedposition of the previous air direction.
Note: 1 Air direction is set to the standard position when the unit is shipped from the factory. The position can be changed from the remote controller.2 Closing of the corner discharge outlets is recommended.
Note : Anechoic chamber conversion value, measured according to JISparameters and criteria. During operation these values are some whathigher owing to ambient conditions.
With Ultra long-life filters (option), maintenance is not required in normal shops or offices for up to four years.
**Selected models only Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow,an air discharge outlet sealing material (option) must be used to close each unused outlet. Operation sound increases when using 2-way or 3-way flow.
360° airflow Air movement is gentle with Round Flow
SPECIFICATIONS
OPTIONS
dB(A)
Cooling capacity1,2Rated (Min. - Max.)
kWBtu/h
°CDBCoolingCertified Operation range
Sound level3
°CWBCoolingCertified Operation range
Motor output
Compressor
ModelName
Indoor unit
Outdoor unit
Dimensions(HXWXD)
Colour
mm
mm
dB(A)
kW
Refrigerant charge (R-410A)kg
dB(A)
Dimensions (HXWXD) mmMachine weight kg
Unit
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Decoration panel
Decoration panel
Machine weight kg
kgUnit
Decoration panel
Airflow rate (H/M/L) m3/min
Outdoorunit
Colour
mm
Heat insulation
Max. interunit piping length mmMax. installation level difference
Power supply
Type
Cooling
Sound level (HH/H/M/L)3
Indoorunit
71
FCQ71LUV1
RZR71LVVMG
Hermetically sealed swing type Hermetically sealed swing type1.76
7.1 (3.2-8.0)24,200 (10,900-27,300)
100
FCQ100KAVEA
RZR100MVMG
(43/37.5/-/32)
49 52
990X940X320 990X940X32065
2.03
1.9(Charged for 30 m)
1.9(Charged for 30 m)
32/26/20
9.5 (4.5-11.2)32,400 (15,400-38,200)
125
FCQ125KAVEA
RZR125MVMG
(44/39/-/34)
o/ 9.5o/ 15.9
24
298X840X84050X950X950
5.5
1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
30
Ivory white
Fresh white
Both liquid and gas piping
50 (Equivalent length 70)o/ 26.0 (Hole)
2.03
VP25 (I.Do/ 25XO.Do/ 32)
33/28/22.5
10.8 (5.4-14.0)36,900 (18,400-47,800)
21 to 46
14 to 25
kWPower consumption Cooling1
100
FCQ100KAVEA
RZR100MYM
(-/43/37.5/32
1.92
32/26/20
10.0 (5.0-11.2)34,100 (17,100-38,200)
125
FCQ125KAVEA
RZR125MYM
(-/44/39/34)
73
1.9(Charged for 30 m)
33/28/22.5
12.5 (5.7-14.0)42,700 (19,500-47,800)
140
FCQ140KAVEA
RZR140MYM
(-/44/40/36)
49 52 54
1.92
14.0 (6.2-15.4)47,800 (21,200-52,600)
1.80 2.51 3.22 2.78 4.31 5.62
Night quiet mode
60
FCQ60LUV1
RZR60LVVM
(-/35/-/28)
48
595X845X30043
21
256X840X840
1.35
1.6(Charged for 30 m)
21/-/13.5
6.0 (2.6-6.3)20,500 (8,900-21,500)
1.40W/WCOP 3.78 3.79 3.35 3.60 2.90 2.49
50
FCQ50LUV1
RZR50LVVM
1.12
5.0 (2.3-5.6)17,100 (7,900-19,100)
1.034.85 4.29
454544
Outdoor unit
Cooling only
Note: 1Required for installing high-efficiency filter unit and ultra long-life filter unit. 2Wiring for wired remote controller to be procured locally.3Installation box for adaptor PCB (KRP1H98) is necessary.
Kit name
BRC1E62
KDDFP55B160
KDBH55K160FKDBP55H160FA
KKSJ55KA160
KDDP55B160KDDP55B160KKDDP55X160
KRP4AA53
KAFP551K160
BRC7F633F BRC7F635FBRC1C61
BYCP125K-W1
KRP1H98
KAFP55B160KAFP55H160H
FCQ100/125/140KAVEAFCQ50/60/71LUV1Name of option Remark
Chamber type
Decoration panel
Fresh air intake kit
Without T-joint pipe and fanWith T-joint pipe, without fan
Direct installation type
Sealing material of air discharge outletPanel spacer
Chamber connection kit1
Wiring adaptor for electrical appendices (2)3
Installation box for adaptor PCB
Filter chamber Replacement long-life filterUltra long-life filter unit (including filter chamber)Replacement ultra long-life filter
Remote controller
Navigation Remote Controller
Wireless type
Wired type2Wired type2
OOO
Compact Body for Quick & EasyInstallation in Tight Ceiling(50LU-71LU)
256 mm *1 266 mm *2
*1 298 mm high with 100–140 KA/LU*2 308 mm high with 100–140 KA/LU
Easy Maintenance
Drain plug
Just open th
e
suction gril
le!
Drain Pump is Equipped as Standard Accessory with 850 mmLift.
175 mm
850 mm
The condition of the drain pan anddrain water can be checked byremoving the drain plug andsuction grille.
CEILING MOUNTED CASSETTE TYPE Round Flow
10 11
Cassette Air Conditioner with 360° Uniform Airflow sets The Standard
Note : 1Rated cooling capacities are based on the following conditions: Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 2Capacities are net, including a deduction for cooling for indoor fan motor heat. 3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
-
Design and Installation Flexibility
Easy Maintenance
With a height of only 245 mm, installation is possibleeven in buildings with narrow ceiling spaces
Using a DC fan motor, the external static pressure can be controlled to within a range of 50 Pa to 150 Pa
Higher lift is realized by utilising built-in DC drain pump with standard accessory
850mm
Comfort airflow is achieved in accordance with conditions such as duct length.
Adjustable external static pressure
50 Pa 150 Pa
Set to high static pressure for advanced needs such as when using dampers and long ducts.
Set to low static pressure when ducts
are short.
Drain pan maintenance check window
Easy maintenance because the drain pan can be removed
Inspection opening for drain pan
Drain pan maintenance check window
This makes it possible to inspect for drain pan dirt and to confirm drainage during installation without the use of tools.
Controls the airflow rate using a remote controller during test run.It is automatically adjusted to approximately ±10% of the rated H tap airflow.
Airflow rate auto adjustment function
Enables central control of room ventilation and lighting by third-party building management system.
Enables control by hotel key card system acting as master ON/OFF for room electricity.
Interlock control by outside system
245
100/125/140E
1,000 1,400
800
Height
Indoor unit
WidthDepth
71E
(mm)
(mm)
(mm)
245mm
Position of drain pan inspection opening has been modified for easier inspection work
Clean
A built-in antibacterial treatment that uses silver ion in the drain pan prevents the growth of slime, bacteria, and mould that cause smells and clogging.
Silver ion anti-bacterial drain pan
High EfficiencyDC Fan motor and DC drain pump are utilised to improve energy efficiency
One of the industry’s most compact bodies in the mid-static pressure range.
Interlock
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
12 13
Thinner Design Allows GreaterInstallation Flexibility
OPTIONS
1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)2Capacities are net, including a deduction for cooling for indoor fan motor heat.3External static pressure is changeable in 11 stages by remote controller.4Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 5Air filter is not standard accessory, but please mount it in the dust system of the suction side. Select its duct collection efficiency(gravity method)50% or more.
Note:
FBQ50EVE FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVEName of option Remark
Adaptor for wiring
Wiring adaptor for electrical appendices(2)
Remote sensor
Mounting plate for adaptor PCB.2,3,4
Central remote controller5
Unified ON/OFF controller5
Schedule timer5
intelligent Touch Controller5
Remote controller
Wired type1Wireless type Cooling only
Kit name
Navigation Remote Controller1
BRC4C66
BRC1C61
BRC1E62
KRCS01-4B
KRP4A98
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
Only one mounting plate can be installed for each indoor unit.Mounting plate is necessary for each adaptor marked .
Note: 1
3
4
Up to 2 adaptors can be fixed for each mounting plate.
2Wiring for wired remote controller to be procured locally.
5The indoor unit is equipped standardly with the interface adaptor for SkyAir series.The Interface adaptor for SkyAir series is not necessary for this indoor unit since it is equipped as standard.
KRP1C64
KRP4AA51
Model
Name
Indoor unit
Outdoor unit
Indoor unit
kWBtu/h
kWCooling1Power consumption
Indoorunit
Sound pressure level (H/M/L)4 dB(A)Dimensions (HXWXD)Machine weight (indoor)
mmkg
Airflow rate (H/M/L)
Outdoorunit
Piping connection
m3/minFanExternal static pressure3 Pa
FBQ100EVE
RZR100MYM RZR125MYM RZR140MYM
FBQ125EVE FBQ140EVE
Cooling capacity1,2
Rated (Min. - Max.)
Power supplyOutdoor unit
100 125 140
40/37.5/3540/37.5/35
38/35.5/33
245X1,400X800
36/30.5/25
2.82
10.0 (5.0-11.2)34,100 (17,100-28,200)
12.5 (5.7-14.0)42,700 (19,500-47,800)
14.0 (6.2-15.4)47,800 (21,200-52,600)
4.58 5.85
Rated 50 (50-150)
Sound pressurelevel4
dB(A)
Dimensions (HXWXD)Machine weight (outdoor)
Max interunit piping length
mm
Cooling
Indoor unitOutdoor unit
dB(A)Night quiet mode
4945
990X940X320
5452
47
3 Phase, 380–415 V, 50 Hz
1 Phase, 220–240 V, 50 Hz
3.55 2.73 2.39COP W/W
kgmmmmmmmmm
LiquidGas
Drain
73o/ 9.5 (Flare)
o/ 15.9 (Flare)VP25 (I.Do/ 25×O.Do/ 32)
o/ 26 (Hole)50 (Equivalent length 70m)
SPECIFICATIONS
Model
Name
Indoor unit
Outdoor unit
Indoor unit
kWBtu/h
kWCooling1Power consumption
Indoorunit
Sound pressure level (H/M/L)4 dB(A)
Sound pressurelevel4
dB(A)
Dimensions (HXWXD) mm
Dimensions (HXWXD)Machine weight (indoor)
mmkg
Airflow rate (H/M/L)
Outdoorunit
Piping connection
m3/minFanExternal static pressure3 Pa
Cooling
dB(A)Night quiet mode
FBQ50EVE
RZR50LVVM
Cooling capacity1,2
Rated (Min. - Max.)
Power supplyOutdoor unit
50
5.0 (2.3-5.6)17,100 (7,900-19,100)
1.39
35/33/31 38/35/33 38/35.5/33 40/37.5/35
18/15/12.5 36/30.5/2523/19.5/16 32/27/22.5
245X1,000X800
595X845X300 990X940X320
245X1,400X800
COP1.69 2.22 2.51 3.22
6.0 (2.6-6.3)20,500 (8,900-21,500)
7.1 (3.2-8.0)24,200 (10,900-27,300)
9.5 (4.5-11.2)32,400 (15,400-38,200)
10.8 (5.4-14.0)36,900 (18,400-47,800)
Rated 50 (50-150)
44 454837
4947
52
FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE
RZR60LVVM RZR71LVVMG RZR100MVMG RZR125MVMG
60 71 100 125
1 Phase, 220-240 V, 50 Hz
W/WCOP 3.60 3.56 3.20 3.79 3.35
Machine weight (outdoor) kg 43 65Liquid mm o/ 9.5 (Flare)Gas mm o/ 15.9 (Flare)Drain mm VP25 (I.Do/ 25×O.Do/ 32
Outdoor unit
Indoor unit
mm o/ 26 (Hole) Max interunit piping length mm 50 (Equivalent length 70m)
Heat insulation Both liquid and gas piping
Heat insulation Both liquid and gas piping
-
Uses quiet stream fan and other quiet technologies.
Turbulent flow is reduced
Straightening plate Quiet stream fan
Easy Maintenance
Oil Resistant Grille
Long-life filter (standard) requires no maintenance forabout 1 year*
Easy-clean, flat surfaces(FHQ50-125BV)
High/Middle/Low : 46/42/38 dB(A)
Quiet Operation at 32** dB(A)**Selected models only
The technology of the DC fan motor, wide sirocco fan, and large heat exchanger combine for greater airflowand quiet operation.
Sophisticated design
Installable on ceilings 4.3 m high
3 fan speeds: High/Middle/Low
Connection to a centralised control systemis available, without option.
Flap neatly closes whennot in use.
Fresh white colour.
The filter is washable and reused after 1 year.* For dust concentration of 0.15 mg/m3
Two time settings (2500 hrs and 1250 hrs) are available to match the installationenvironment. Maintenance time warning is displayed on the remote controller(filter sign).
Oil-resistant plastic is used for the air suction grille.This satisfies durability in restaurants and other similar environments.Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specificationis not suitable for kitchens or other harsh environments.
Comfortable
Programme “Dry”Dehumidification is a microprocessor controlled to preventabrupt and uncomfortable changes in air temperture.
Auto swing (up and down) and louvers (left and right by hand) bring comfort to the room
Louver manually adjustsfor straight or wide angleairflow
Drain pump kit (built inside main unit)
600 mm
Drain pump kit (option) includesa silver ion antibacterial agentthat assists in preventing the growth of slime, bacteria and mould that cause smells and clogging.
Drain pump kit can be easily incorporated
Kit nameName of option
FHQ50/60BVV1GKAF501DA80
Remark
Replacement long-life filter
Remote controller
Resin net
Wireless type
Wiring adaptor for electrical appendices2
Interface adaptor for SkyAir seriesInstallation box for adaptor PCB
Note: 1Wiring for wired remote controller to be procured locally.2Installation box for adaptor PCB (KRP1D93A) is necessary.
Cooling only
FHQ100BVV1B FHQ125BVV1B
KRP4AA52DTA112BA51KRP1CA93
KAF501DA112 KAF501DA160 KAFP501A160
BRC7GA56KDU50P140VE
KRP1D93AN/A
KDU50N125VEBRC7EA66
BRC1C61BRC1E62Navigation Remote Controller Wired type1
Wired type1
Drain pump kit
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).2Capacities are net, including a deduction for cooling for indoor fan motor heat.3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
FHQ100/125/140DAVMA
14 15
CEILING SUSPENDED TYPE
SPECIFICATIONS
OPTIONS
Refrigerant charge (R-410A)
VP20 (I.Do/ 20XO.Do/ 26)
Hermetically sealed swing type
30
100
FHQ100DAVMA
RZR100MYM
o/ 9.5o/ 15.9
990X940X320
o/ 26.0 (Hole)
49
1.92
1.9(Charged for 30 m)
Ivory white °CWB
kW
Btu/h
kWPower consumption
°CDBCertified operation range
Certified operation range
Motor output
Cooling
Night quiet mode
Compressor
ModelName
Indoor unit
Outdoor unit
Dimensions (HXWXD)
Colour
mm
dB(A)
kW
Refrigerant charge (R-410A) kg
dB(A)
dB(A)Sound level3
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Machine weight kg
Airflow rate (H/M/L) m3/min
Outdoorunit
Colour
mm
Heat insulation
Max. interunit piping length mmMax. installation level difference
Power supply
Type
Sound level (H/M/L)2
Indoorunit
Both liquid and gas piping
Cooling capacity1,2Rated (Min. - Max.)
21 to 46
14 to 25
125
FHQ125DAVMA
RZR125MYM
73
50 (Equivalent length 70)
W/WCOPCooling1
Outdoor unit
140
FHQ140DAVMA
RZR140MYM
42/38/3428/24/20
44/41/3731/27/23
Light Ivory
235X1,590X69038
10.0 (5.0-11.2)34,100 (17,100-38,200)
3.033.3
12.5 (5.7-14.0)42,700 (19,500-47,800)
4.422.83
14.0 (6.2-15.4)47,800 (21,200-52,600)
5.552.52
46/42/3834/29/24
52 5445 46
3 Phase, 380–415 V, 50 Hz
CEILING SUSPENDED TYPE
Throughout The Room
-
Auto-swing 5-level air direction setting
Wide-angle louvers (by hand)
Comfortable
Soft material louver bends airflow over a wider area
Gettable to 5 different levels
Dehumidification is microprocessor controlled to preventabrupt and uncomfortable changes in air temperature.
Compact & Sophisticated DesignFAQ100
1,200mm
340mm
9kg lighterHeight
FAQ100BV
360mm
Width 1,570mm
Weight 26kg
FAQ100C
340mm
1,200mm
17kg
Depth 200mm 240mm Drain Pump Kit is Available as Option.
Height of drain up
Drain pump kitIndoor unit
Installs onto side of unit.
1,000 mm
Refrigerant piping
Connection to a centralised control systemis available without option
Easy Cleaning
Compact Design and Easy Installation
BRC1C61
Note: 1Wiring for wired remote controller to be procured locally.
Name of option Remark
Remote controller
Wiring adaptor for electrical appendices
Kit nameFAQ100CVEA
KRP4AA51
Drain-up kit
Installation box for adaptor PCB
K-KDU572EVE
KRP4AA93
BRC7EB519Wireless type
BRC1E62Navigation Remote Controller Wired type1Wired type1
Cooling only
°CWB
Cooling capacity1,2Rated (Min. - Max.)
kWBtu/h
kWPower consumption
°CDBCertified Operation range
Certified Operation range
Sound level3
Motor outputCompressor
ModelName
Indoor unit
Dimensions (HXWXD)
Colour
mmdB(A)
kWRefrigerant charge (R-410A) kg
dB(A)
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Machine weight kg
Airflow rate (H/M/L)
Outdoorunit
Colour
mm
Heat insulation
Max. interunit piping length mmMax. installation level difference
Power supply
Type
Cooling1
Cooling
Sound level (H/M/L)3
Indoorunit
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).2Capacities are net, including a deduction for cooling for indoor fan motor heat.3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
m3/min
100
FAQ100CVEA
RZR100MYM
49/45/41
17340X1,200X240
o/ 9.5
49
Ivory white
30Both liquid and gas piping
Fresh white
o/ 15.9
Hermetically sealed swing type
o/ 26.0 (Hole)
1.9 (Charged for 30 m)
10.0 (5.0-11.2)34,100 (17,100-38,200)
26/23/19
21 to 46
50 (Equivalent length 70m)
14 to 25
dB(A)Night quiet mode 45990X940X320
73
1.92
VP13 (I.Do/ 13 X O.Do/ 18)
3.37W/WCOP 2.97
3 Phase, 380–415 V, 50 Hz
Outdoor unit
Outdoor unit
-
18 19
*1 : Applicable when BRC1E62 is used*2 : Applicable when wired remote controller is used
*3 : For outdoor units*4 : Applicable when BRC1C61 is used
*5 : Applicable for FVQ50-100*6 : Installable on max. 3.5 m (50-71) and 4.3 cm.(100-140 ) high ceiling
*7 : Installable on max. 4.3 m high ceiling*8 : Option
*9 : Applicable for 60/71 class indoor unit*10 : Applicable for RZR50-71M, RZR-LV and RZR-LU
Cooling onlyRZR50-60LVVMRZR71LVVMG
RZR50-60LVVM,RZR71LVVMGRZR100-125MVMG,RZR100-140MYM
Indoor unit
Outdoor unit
Comfort
Cleanliness
Remote Controller
Work & servicing
Control features
Options
Others
Note:
Auto swing
Swing pattern selection
DC fan motor (Indoor unit)
Independent up-and-down airflow
Switchable fan speed
Auto airflow rate*1
Program “Dry”
High fan speed mode
High ceiling application
Two selectable temperature-sensors *2
Year-round cooling applicable
Night quiet operation *3
Setpoint auto reset *1
Setpoint range set *1
Weekly schedule timer *1
Off timer (programmed) *1
On/Off timer *4
Anti-bacterial air filter
Mould-proof air filter
Silver ion anti-bacterial drain pan
Mould-proof drain pan
Drain pump mechanism
Pre-charged for up to 30 m *3
Pre-charged for up to 10 m *3
Long-life filter
Filter sign
Ceiling soiling prevention
Low gas pressure detection *3
Emergency operation
Self-diagnosis function
Auto-restart
Control by 2 remote controllers
Group control by 1 remote controller
External command control
Central remote control
Interlock control with Heat Reclaim Ventilator
DIII-NET communication standard
High-efficiency filter
Ultra long-life filter
Fresh air intake kit
Anti corrosion treated heat exchangers *3
FunctionsoverviewFunctionsoverview
CEILING MOUNTED CASSETTE TYPE CEILING SUSPENDED TYPERound Flow
*8
2step
RZR100-125MVMG,RZR100-140MYM
*8
*10
3step
*8
*8
*10
3step
FAQ100CVEA
RZR100MYM
*10
*8
*8
*8
3step
FBQ50-140EVE
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
NEWFCQ50-71LUV1 FCQ100-140KAVEA
NEW
WALL MOUNTED TYPE
FHQ100-140DAVMA
RZR100-140MYM
*8
Only for DA series
Only for DA series
*8
*6
3step for DA
NEW
-
20 21
If there is a malfunction elsewhere in the system, the fan or compressor can still be operated.
Insufficient gas charging is normally hard to detect. During post-installation trials and regular inspection procedures, the refrigerant level is monitored by microprocessor to maintain proper gas pressure. Reliability is assured and maintenance and inspection can be carried out more quickly.
You can turn up to 16 indoor units on/off with a single remote controller. (When using connected indoor units, the settings must all be the same and on/off will be simultaneous.)
Emergency operation
Low gas pressure detection
Group control by 1 remote controller
Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room.
External command control
Optional central remote controller enables centralised control of up to 1024 indoor units (64 groups) from up to 1 kilometer away.
Central remote control
Enables interlocking control with external equipment such as Heat Reclaim Ventilator.
Interlock control
The operating parameters of indoor and outdoor units, and sensor data at critical locations throughout the system, are constantly monitored using a microcomputer. To facilitate quick response in the event of a malfunction, a message appears on the LCD of the remote controller and an LED on the unit illuminates.
Self diagnosis function
Work and Servicing
Control features
Options
Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping.
Maintenance is not required for one year*.The filter is washable and can be reused.
If refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging.
The filter sign warns you when it is time to clean the filter. *When using a wired remote controller the sign is displayed in the LCD. When using a wireless remote controller the filter sign lamp illuminates on the signal receiver unit.
Drain pump mechanism
Long-life filter
Pre charged for up to 30 metres
Filter sign
Daikin's innovative air discharge mechanism keeps airflow away from the ceiling. Ceiling cleaning is less frequently required.
Ceiling soiling prevention function
If there is a power outage while the equipment is operating, operations will restart in the same mode as before the power cut when electricity is restored.
Auto-restart
Using 2 remote controllers you can operate the equipment locally or from a remote location.Note: It is not possible to use two wireless remote controllers.
Control by 2 remote controllers
RXS50FA/60F/71F,RKS25A/35A : 10 m*Applicable to RZR50-140.
*An option is required.
Others
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated Anti corrosion treated heat exchangers (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.In high corrosive areas, regular maintenance needs to be carried out.
Anti corrosion treated heat exchangers
Standardly equipped interface enables connection to centralised control system without need of an adaptor.
DIII-NET communication standard
*For dust concentration of 0.15 mg/m3
Mould-proof drain pan prevents growth of mould in highly humid conditions.
Mould-proof drain pan
Cleanliness
The Air filter has a anti-bacterial treatment to help prevent the growth of bacteria and mould on it.
Anti-bacterial air filterSanitary filter has mould-resistant treatment.
Mould-proof air filter
Note: Wireless remote controllers have no temperature-sensor.
Use the temperature-sensor in the indoor unit when controlling air conditioning from another room.
Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Useful for reducing uncomfortable humidity without uncomfortable cooling of the room.
Delivers comfortable air-conditioning to all areas, near to and far from the air-conditioner.
High setting provides maximum reach while low setting minimises drafts.
You can freely set air discharge setting by remote controller.
Auto-swing Programme "Dry"
Switchable fan speed
(1) Air direction in standard setting
(3) Air direction in ceiling soiling prevention setting
Note: When units are installed on high ceilings, depending on the model, various restrictions concerning maximum height, air discharge direction, and choice of options may apply.
Swing pattern selection
Delivers air-conditioning comfort all the way down to the floor in air-conditioning zones with high ceilings.
High-ceiling application
Airflow rate is automatically controlled in accordance with the difference between room temperature and set temperature.
Auto airflow rate
Two selectable temperature-sensors
Comfort
The air flow direction can be fixed at your desited angle by the remote controller.
Temperature-sensors are included in the indoor unit and optional wired remote controller. Temperature sensing closer to target area is possible to further increase the comfort level.
Remote Controller
Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts.
Off timer (programmed)
Operation starts when the preset time of the ON timer elapses and stops when the preset time of the OFF timer elapses.
On/Off timer
Up to five operation ON/OFF settings can be programmed per day for each day of the week. Not only can the time be set for the operation ON setting, but also the temperature.
Weekly schedule timer
Even if the set temperature is changed, it returns to the preset temperature after a preset period of time.
Saves energy by limiting the minimum and maximum set temperatures. Avoids excessive heating and cooling.
Setpoint auto reset
Setpoint range set
You can increase fan speed approximately 10% higher than the "high" setting.
High fan speed mode The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime, and normal operation will resume 10 hours after that.
Night quiet operation
Independently adjust (manually) the eight horizontal blade louvers in both up and down directions to achieve an airflow that reduces uneven room temperature.
Independent up-and-down airflow
(2) Air direction in draft prevention setting
Two types are available: 65% and 90% colorimetry.
High-efficiency filter unitYou can provide air-conditioning with fresh air from outside. Convenient for places where a ventilation fan cannot be installed.
Fresh-air intake kit
Ultra long-life filterRequires no maintenance for about 4 years* (10,000h) in stores and offices.*For dust concentration of 0.15 mg/m3
*Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating noise and may also influence temperature sending.
Note:
Mould-proof drain pan includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging.
Silver ion anti-bacterial drain pan
-
22 23
LCD REMOTE CONTROLLER Optional accessory
Easy-to-read LCD remote controller allows various system control configurationsand can control multiple indoor units.
Interface adaptor for SkyAir series
Easily adaptable to large-scale, high-function, centralised remote control system.
DTA112BA51 (Option)
With its high functionality, the full colour “all-in-one” graphic controller facilitates management of SkyAir System in a variety of ways.
DCS601C51 (Option)
Unified on/off controller
Centralised control of on/off by group or all at once for up to 256 indoor units.
DCS301BA61 (Option)
Schedule timer
Unified control of weekly schedule for up to 1,024 indoor units.
DST301BA61 (Option)
Schedule timer sets on/off time in 1 minute units to be executed twice a day for a week at a time.
Central remote controller
Centralised control, with setting as simple as it is with a standardremote controller, of up to 64 groups (1,024 indoor units) is possible.
DCS302CA61 (Option)
Enables centralised control via connection to a high-speed, DIII-NET communication system, adopted for the Daikin VRV system.Necessary for interface adaptor for SkyAir series with the central remote control units shown at above.
The interface adaptor for the SkyAir series is optional except for the ceiling mounted cassette type < Round Flow >,duct connection middle static (CA/DA series) pressure type,wall mounted type and floor standing type.
Navigation Remote Controller (Wired Remote Controller BRC1E62)
Wired LCD remote controller
This simple, modern designed remote controller with fresh white colour matches your interior design. Operation is much easier and smoother, just follow the indications on the navigation remote controller.
Energy savingEnergy saving
- Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts.- Period can be preset from 30 to 180 minutes in10-minute increments.
Off timer (programmed)
Setpoint range set
Setpoint auto reset
Restaurant sample
- Saves energy by limiting the min. and max. set temperature.- Avoids excessive heating or cooling. - This function is convenient when the remote controller is installed at a place where
any number of people may operate it.
- Even if the set temperature is changed, it returns to the preset temperature after apreset period of time.- Period selectable from 30min/60min/90min/120min.
Restaurant opened
Temperature is set to 27ºC
27°C
Full tables at lunchtime
Then is lowered to 24ºC for crowded room
24°C
After 30 minutes*
Automatically returns to preset temperature (27ºC)
*Setting possible for after 30, 60, 90, and 120 minutes.
Returns to
27°Cautomatically
BRC1C61
The rubber switch and the oil-resistant plastic
casing are adopted for durability.
Only 17 mm thick. Can be installed either recessed
or exposed.
Easy to read because of large LCD screen.
LCD wireless remote controller
Signal receiver unit (For FHQ140CA)
Wireless remote controller
Clear Display with Backlight
Backlightdisplay
Convenience
Weeklyschedule
BRC7GA56
The wireless remote controller is supplied
in a set with a signal receiver.
Signal receiver unit is contained inside
decoration panel or indoor unit
Shape of signal receiver unit differs
according to the indoor unit.
Note: The signal receiver unit shown in the photograph is for mounting inside the decoration panel of the ceiling suspended type.
-
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.
Cautions on product corrosion
Warning Ask a qualified installer or contractor to install this product. Do not try to install the product by yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.
Read the user's manual carefully before using this product. The user's manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Specifications, designs and other content appearing in this brochure are current as of December 2018 but subject to change without notice.
10 Ang Mo Kio Industrial Park 2 Singapore 569501Daikin Airconditioning (Singapore) PTE.LTD.10 Ang Mo Kio Industrial Park 2 Singapore 569501