Daikin AC Price List 2013

125
Daikin UK Price List 2013 Integrated solutions your comfort. our world. Split, Sky Air Heat Pumps VRV® Ventilation Commercial Heating Refrigeration Applied Miscellaneous

Transcript of Daikin AC Price List 2013

Page 1: Daikin AC Price List 2013

Daikin UK Price List 2013Integrated solutions

your comfort. our world.

Split

, Sky

Air

Hea

t Pum

psVR

V®Ve

ntila

tion

Com

mer

cial

Hea

ting

Refr

iger

atio

nA

pplie

dM

isce

llane

ous

Page 2: Daikin AC Price List 2013

London head officeDaikin UKThe Heights, Brooklands, WeybridgeSurrey KT13 0NY Telephone 0845 641 9300

Bristol officeDaikin UKMaple House, Brotherswood CourtGreat Park Road, AlmondsburyBristol BS32 4QW Telephone 0845 641 9320

Birmingham officeDaikin UKUnit 8, Holly Park, Spitfire RoadBirmingham, West Midlands B24 9PB Telephone 0845 641 9370

Manchester officeDaikin UK17b Cobra Court, Blackmore RoadManchester M32 0QY Telephone 0845 641 9340

Glasgow officeDaikin UKUnit 2, Glasgow Airport Business Park Marchburn Drive, Paisley PA3 2SJ Telephone 0845 641 9330

As a wholly owned subsidiary of Daikin Europe NV, Daikin UK is a leading supplier of heating and cooling solutions for residential, commercial and industrial applications. Our product portfolio comprises a wide range of highly energy efficient climate control systems which provides the right solution for any application and requirement.

Daikin UK is a nationwide organisation with its headquarters in Weybridge, Surrey. Strategically situated regional sales offices achieve efficient response combined with administration, distribution and field quality service departments.

Daikin UK

Conditions

Capacity conditionsUnit cooling and heating capacities shown within this price list are based on the following conditions:

Nominal cooling Ambient = 35°CInternal = 27°C db 19°C wb

Nominal heating Ambient = 7°C db 6°C wbInternal = 20°C db

UK cooling Ambient = 30°CInternal = 22°C db 16°C wb

Seasonal efficiencySystems of up to 12kW must now show Seasonal Efficiency Ratings instead of Nominal Efficiency Ratings. These ratings (SEER for cooling, SCOP for heating) represent how effective a system is throughout the year, and are in accordance with EN14825. For more information on Seasonal Efficiency, visit www.daikin.co.uk/seasonal-efficiency

For Daikin UK, this means all our Split and Sky Air products up to 12kW display SEER and SCOP data along with Energy Label information and Annual Energy Consumption of the system. The AEC is based upon 500 hours use per year.

Nominal efficiency This measure of efficiency is calculated by dividing the capacity output of a unit by the power required to deliver it. For cooling, this is expressed as EER, for heating as COP.

Nominal efficiencies are used for systems above 12kW. It is not possible to compare nominal and Seasonal Efficiency ratings.

Cooling mode

Unless otherwise indicated, all units within this price list are air-cooled.

UK. prefix accessories All accessory items shown in this price list with the prefix ‘UK.’ are not manufactured by Daikin.

Page 3: Daikin AC Price List 2013

1

Split

, Sky

Air

Hea

t Pum

ps

Price List 2013

Split

, Sky

Air

Hea

t Pum

psVR

V®Ve

ntila

tion

Com

mer

cial

Hea

ting

Refr

iger

atio

nA

pplie

dM

isce

llane

ous

Discount RatingPlease insert your discounts here and then refer to the colour tabs on the edge of each page for reference.

Applied

MY DISCOUNT

%

Ventilation

MY DISCOUNT

%

Refrigeration

MY DISCOUNT

%

VRV®

MY DISCOUNT

%

Commercial Heating

MY DISCOUNT

%

Split, Sky Air Heat Pumps

MY DISCOUNT

%

ContentsNew for 2013 02

Split, Sky Air Heat Pumps 04

VRV® 43

Ventilation 87

Commercial Heating 89

Refrigeration 93

Applied 97

Miscellaneous 111

Page 4: Daikin AC Price List 2013

Integrated Solutions2

Page 19 - 21 / 46

Page 45

Page 22 - 23 / 44

Page 58 - 61

VRV®IV heaT PUMP – RYYQ-T

• Variable refrigerant temperature Customise your VRV for best seasonal efficiency

• Continuous comfort The new standard in heating comfort

• VRV configurator Software for simplified commissioning, configuration and customisation

FULLY FLaT casseTTe – FFQ-c / FXZQ-a

• Unique design in the market: integrates fully flat into the ceiling and fits flush into architectural ceiling modules

• Remarkable blend of iconic design and engineering excellence with an elegant finish in matt crystal white or a combination of silver and matt crystal white

• Even more energy efficient with the presence sensor (optional)

• Offering improved comfort with the floor sensor (optional)

• Individual flap control: one flap can be easily closed via the wired remote controller (BRC1E52A) when refurbishing or rearranging your interior

• No optional adapter needed for DIII-connection of Sky Air model

2-waY BLow ceILING MoUNTeD casseTTe – FXcQ-a

• Low energy consumption thanks to specially developed small tube heat exchanger, DC inverter fans and drain pumps

• Stylish unit blends easily with any interior, as the flaps close entirely when not in operation

• Improved comfort with automatic air flow adjustment to required load

• Individual flap control: one flap can be easily closed via the wired remote controller (BRC1E52A) when refurbishing or rearranging your interior

ceILING sUsPeNDeD casseTTe – FhQ-c / FXhQ-a

• Low energy consumption thanks to DC inverter fans and drain pumps

• Stylish unit blends easily with any interior, as the flaps close entirely when not in operation

• No optional adapter needed for DIII-connection of Sky Air model

sLIM coNceaLeD ceILING UNIT – FDXs-F / FXDQ-a

• For residential applications

• Compatible with Split, Sky Air, VRV III-S

• Reduced fan motor consumption thanks to the DC fan motor

New for 2013New

New

New

New

New

Page 32 / 47

Page 5: Daikin AC Price List 2013

Price List 2013 3

4-waY BLow ceILING sUsPeNDeD UNIT – FUQ-c / FXUQ-a

• Low energy consumption thanks to specially developed small tube heat exchanger, DC inverter fans and drain pumps

• Stylish unit blends easily with any interior, as the flaps close entirely when not in operation

• Improved comfort with automatic air flow adjustment to required load

• Same outlook for all models (unified dimensions)

• No optional adapter needed for DIII-connection of Sky Air model

• Separate BEVQ box is no longer needed for VRV model: the expansion valve is integrated in the indoor unit

INTeLLIGeNT ToUch MaNaGeR – DcM601a51

• Intuitive user interface

• Smart energy management

• Flexible in size (from 64 to 2,560 groups)

• Flexible integration (from simple A/C control to small BMS)

• Easy servicing and commissioning with remote refrigerant containment check

DaIKIN seRVIce aPP

• To help installation and service engineers, Daikin UK has developed a new service tool, which provides fast access to information when working with Daikin VRV products

• Flexible integration (from simple A/C control to small BMS)

• Easy servicing and commissioning with remote refrigerant containment check

• The Daikin service application is for iphone and ipads

• Available at the Apple App Store

• Designed to help field engineers to set up and service Daikin VRV equipment

DaIKIN cITY

• Daikin UK has launched Daikin City 2.0, a major upgrade of its interactive virtual environment that now features a library and a broadcast centre

• The library already contains over 120 brochures and data books regularly, as well as specification documents, case studies, industry guides and operation manuals

waLL MoUNTeD UNITs – FTXs-K

• Extension with 35-, 42- and 50-class

• Discrete, modern design

• High quality matt crystal white finish

• Whisper quiet in operation. Sound pressure level down to 19dBA

• Intelligent Eye sensor enhances comfort and saves energy

Page 10

New

Page 29 / 46

New

Page 82

New

New

New

Page 6: Daikin AC Price List 2013

4

Split

, Sky

Air

Hea

t Pum

ps

Page 7: Daikin AC Price List 2013

5

Split

, Sky

Air

Hea

t Pum

ps

scotland Region

0845 641 9330

Northern Region

0845 641 9340

Midlands Region

0845 641 9370

western Region

0845 641 9320

North London

0845 641 9360

south London

0845 641 9355

Split, Sky Air Heat Pumpsenergy efficiency 6

Introduction 7

Pair applications 8

Wall Mounted Split Systems 8

Floor Standing Split Systems 14

Flexi Type Split Systems 18

Ceiling Mounted Split Systems 19

Cassette Split Systems 22

Ceiling Suspended Cassette Split Systems 29

Ducted Split Systems 30

Multi applications 34

Multi Split Systems 34

Twin, Triple, Double Twin Systems 36

Page 8: Daikin AC Price List 2013

Integrated Solutions6

Split

, Sky

Air

Hea

t Pum

ps

The new energy labelling indicates the energy efficiency of the product from A+++, A++, A+, A, B etc and, unlike the old label, it includes cooling and heating. It also states the sound emissions of the unit.

It is not possible to simply compare new and old energy classes (i.e. an old ‘A label’ is not equivalent to a new ‘A label’). There is no direct relation between SEER and EER. The energy label will be provided in the box with the outdoor unit and on the Energy Label Generator.www.daikineurope.com/energylabel

How the new energy label looks

By the year

2020Europeanaction plan20/20/20

Co2 EMiSSioNSvs. 1990

-20%Share of RENEWABlE ENERGY

20%PRiMARY ENERGY USE vs. Business as usual

-20%

cooLING• Energy label• Design capacity of the system (Pdesign = 35c)• SEER rating • Annual energy consumption

heaTING• Energy label• Design capacity of the system for the average climate zone (Pdesign = -10c)• SCOP rating • Annual energy consumption

soUND PoweR• Sound level indoor• Sound level outdoor

The European Union 20/20/20 energy policy sets ambitious targets for energy efficiency and environmental impact:

The ErP DirectiveThe Energy related Products (ErP) Directive specifies minimum efficiency requirements, which must be integrated into energy-using products. The ErP Directive is a compulsory programme which established EcoDesign requirements initially for residential lighting and consumer electronics – but from 2013, has introduced them for air conditioning systems too.

So far, products of less than 12kW are governed by the ErP Directive (Lot 10): typically high end residential and light

commercial applications. Products that do not meet minimum Seasonal Efficiency standards cannot carry the CE mark and can no longer be imported or sold in Europe.

Timescales for ImplementationLow efficiency products are banned from the market from January 2013. The minimum energy efficiency threshold will be redefined again in 2014, so even higher efficiency levels will be required to meet the ever stricter energy efficiency requirements.

The EU 20/20/20 targets

co2

Page 9: Daikin AC Price List 2013

The Sky Air Seasonal Smart outdoor unit offers at least 20% better performance than existing inverter solutions, which is fully in line with 20/20/20 EU policy. The technology used gives very high levels of Seasonal Efficiency while improving comfort and reducing running costs. Performance can be further enhanced with smart use of Daikin’s unique options and settings.

Seasonal Smart can be used in a wide range of applications through features such as:

• ‘EDP’ setting for use in low humidity, continuous cooling applications such as computer and IT rooms

• R22/R407 c replacement technology to help deliver major energy savings and rapid payback

• Guaranteed operation in heating mode down to -20°C external temperature

• 75m pipe run to allow longer distance between indoor and outdoor units

• D-BACS compatibility to link the Sky Air system into a wider building management system

• Customisable evaporating and condensing temperatures to improve operating efficiencies and reduce draughts

• 3 phase and single phase power for all capacities

Price List 2013 7

Split

, Sky

Air

Hea

t Pum

ps

The Sky Air Seasonal Classic outdoor unit offers seasonal performance for a range of applications, allowing a system to comply with the new regulations in a cost-effective way.

Seasonal Classic now has a compact single fan casing for the 6.8kW, 9.5kW and 12.0kW units making it more suitable to be installed in smaller spaces.

Seasonal Classic also includes:

• R22/R407 c replacement technology to help deliver major energy savings and rapid payback

• Guaranteed operation in heating mode down to -15°C external temperature

• 50m pipe run between indoor and outdoor units

• 3 phase and single phase power units are available

New Sky Air online running cost calculator from Daikin UK

Demonstrate to your customers the savings that can be achieved with a Sky Air solution using Daikin UK’s new online calculator

This will enable you to:

• Calculate running costs for typical applications

• Compare them with Daikin’s unique energy saving options

• Download results as a PDF to attach with your quotes

Try our NEW online running cost calculator today. Visit www.daikin.co.uk/seasonal-efficiency

Daikin again leads the industry with their full light commercial range optimised for seasonal efficiency.

Page 10: Daikin AC Price List 2013

Integrated Solutions8

Split

, Sky

Air

Hea

t Pum

ps

Wall Mounted – InverterUruru Sarara

Indoor Units FTXR28e FTXR42e FTXR50eCapacity UK Total Cooling kW 2.74 4.11 4.89

UK Sensible Cooling kW 2.28 2.93 3.34Nominal Cooling kW 2.80 4.20 5.00Nominal Heating kW 3.60 5.10 6.00

Seasonal Efficiency (EN14825) CooliNG

Energy label B A APdesign kW 2.80 4.20 5.00SEER 4.91 5.46 5.22Annual Energy Consumption kWh 200 269 335

Seasonal Efficiency (EN14825) HEATiNG

Energy label A++ A+ A+Pdesign kW 4.00 4.90 5.60SCoP 5.08 4.50 4.27Annual Energy Consumption kWh 1,101 1,523 1,834

Nominal Efficiency EER / CoP 5 / 5.14 4 / 4.32 3.42 / 3.97Energy label A / A A / A A / AAnnual Energy Consumption kWh 280 525 730

Air Flow Rate High / low m3/min 11.1 / 6.5 12.4 / 6.8 13.3 / 7.3Dimensions Height mm 305 305 305

Width mm 890 890 890Depth mm 209 209 209

Weight kg 14 14 14Sound Pressure High / low dBA 39 / 26 42 / 27 44 / 29Sound Power dBA 55 58 60

outdoor Units RXR28e RXR42e RXR50eDimensions Height x Width x Depth mm 693 x 795 x 285 693 x 795 x 285Weight kg 48 48 48Electrical Details Power Supply 1ph

Running Current A 2.84 4.99 6.92Starting Current A 3.9 5.9 7.4Max Fuse Size A 16 16 16

interconnection Wiring Core / Cable size 3+E / 1.5Piping Connections liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 3/8Pipework Maximum length m 10 10 10

Maximum Vertical Rise m 8 8 8Precharged to m 10 10 10Additional Charge g/m -Holding Charge kg 1.4 1.4 1.4

Sound Pressure High dBA 46 48 50Sound Power dBA 46 48 50

Trade Fan coil Price £322.00 £377.00 £495.00Trade condensing Unit Price £875.00 £1,013.00 £1,066.00Total system Price £1,197.00 £1,390.00 £1,561.00

accessory Ref Description Trade PriceKRP413A1S Adaptor PCB for remote on/off control - constant/pulse contact £73.00 KRP928A2S Adaptor PCB for interface to Daikin centralised control systems £129.00 KliC-DD KNX interface for Split type systems £160.00 RTD-RA Adaptor PCB for Modbus connection and/or extended system functions £156.00 KPMH974A402 2m extension humidification hose- Ururu Sarara £46.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.CGS Condensing Unit Guard size 20-35 £209.00 UK.CGM Condensing Unit Guard size 42-71 £290.00

Accessories: Notes:i) All fan coils supplied as standard with

infrared controller

ii) Minimum ambient operating temperatures:

cooling heatingRXR -10°C -20°C

Features:Daikin introduce a new concept in wall mounted split systems

The ‘Ururu Sarara’ product is unique in providing:• Cooling• Heating• Humidification• De-Humidification• FreshAirIntake• AirPurification• Alltheoperatingmodesneededtoprovideexactlytheroomcomfortrequired,aswellasusingR410ArefrigerantandInvertertechnology,

to provide efficiency exceeding the requirements for Energy Label A

Advanced Remote Control:• Theuserfriendlyremotecontrollerdisplaystheactualroomtemperatureandhumiditylevel• Allcommonlyusedbuttonsareeasilyaccessible,withadvancedcontrolsavailablebeneaththehingedcover• Operatingmodebuttonsarecolourcodedwhichisrepeatedonaindicatorlamponthefancoilcover

This panel changes colour to allow instant identification of the current operating mode

Page 11: Daikin AC Price List 2013

Split

, Sky

Air

Hea

t Pum

ps

Price List 2013 9

Wall Mounted – InverterEmura

Indoor Units Matt crystal white Brushed aluminiumFTXG25Jw FTXG35Jw FTXG50Jw FTXG25Ja FTXG35Ja FTXG50Ja

Capacity UK Total Cooling kW 2.44 3.42 4.46 2.44 3.42 4.46UK Sensible Cooling kW 1.91 2.44 2.93 1.91 2.44 2.93Nominal Cooling kW 2.50 3.50 5.00 2.50 3.50 5.00Nominal Heating kW 3.40 4.00 5.80 3.40 4.00 5.80

Seasonal Efficiency (EN14825) CooliNG

Energy label A++ A++ A A++ A++ APdesign kW 2.50 3.50 5.00 2.50 3.50 5.00SEER 6.53 6.51 5.45 6.53 6.51 5.45Annual Energy Consumption kWh 134 188 321 134 188 321

Seasonal Efficiency (EN14825) HEATiNG

Energy label A+ A+ A A+ A+ APdesign kW 2.80 3.30 4.60 2.80 3.30 4.60SCoP 4.34 4.23 3.87 4.34 4.23 3.87Annual Energy Consumption kWh 903 1091 1660 903 1091 1660

Nominal Efficiency EER / CoP 4.46 / 4.36 3.93 / 4.04 3.21 / 3.63 4.46 / 4.36 3.93 / 4.04 3.21 / 3.63Energy label A / A A / A A / A A / A A / A A / AAnnual Energy Consumption kWh 280 445 780 280 445 780

Air Flow Rate High / low m3/min 8.8 / 4.7 10.1 / 4.6 10.5 / 6.9 8.8 / 4.7 10.1 / 4.6 10.5 / 6.9Dimensions Height mm 295 295 295 295 295 295

Width mm 915 915 915 915 915 915Depth mm 155 155 155 155 155 155

Weight kg 11 11 11 11 11 11Sound Pressure High / low dBA 38 / 25 42 / 26 45 / 35 38 / 25 42 / 26 45 / 35Sound Power dBA 54 58 60 54 58 60

outdoor Units RXG25K RXG35K RXG50K RXG25K RXG35K RXG50KDimensions Height x Width x Depth mm 550 x 765 x 285 735 x 825 x 300 550 x 765 x 285 735 x 825 x 300Weight kg 34 34 48 34 34 48Electrical Details Power Supply 1ph 1ph

Running Current A 2.98 4.78 6.90 2.98 4.78 6.90Starting Current A 4.4 5.6 7.4 4.4 5.6 7.4Max Fuse Size A 16 16 20 16 16 20

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2Pipework Maximum length m 20 20 30 20 20 30

Maximum Vertical Rise m 15 15 20 15 15 20Precharged to m 10 10 10 10 10 10Additional Charge g/m 20.0 20.0Holding Charge kg 1.1 1.1 1.6 1.1 1.1 1.6

Sound Pressure High dBA 46 48 48 46 48 48Sound Power dBA 46 48 48 46 48 48

Trade Fan coil Price £271.00 £304.00 £464.00 £323.00 £362.00 £554.00Trade condensing Unit Price £494.00 £574.00 £918.00 £494.00 £574.00 £918.00Total system Price £765.00 £878.00 £1,382.00 £817.00 £936.00 £1,472.00

Features:• DesignedinEurope,perfectforUKclimates,DaikinEmuracreatestheoptimumcomfortzoneallyearround• Itrepresentsaperfectmarriageofstyleandsubstance,offormandfunction,ofintelligentheatingandefficientcooling• Stylish,low-profiledesign• Soundpressureperformancedownto22dB(A)• Weeklyscheduletimeronthestandardwirelessremotecontrollerallowsprogrammingoftheunitonaweeklybasis,

with the ability to schedule different settings for each day of the week, up to 4 actions per day possible• Specialanti-corrosiontreatmentofthefanandtheheatexchangeroftheoutdoorunit• Pairandmultiapplications(upto9indoorunitscanbeconnectedtoasinglemulticondenser)• IntelligentEyePresenceSensor,switchestoenergysavingmodeifroomisunoccupiedafter20mins• Comfortmode:guaranteesdraughtfreeoperation,directingwarmairdownandcoldairhorizontally• Powerfuloperation:activatesthemaximumairvolumefor20minutesbeforereturningtoitsoriginalsetting• Re-useofexistingR22&R407Cpipingpossible

accessory Ref Description Trade PriceBRC944 optional Wired Remote controller £62.00 BRCW901A03 3m connection cable for BRC944 £16.00 BRCW901A08 8m connection cable for BRC944 £21.00 KRP413A1S Adaptor PCB for remote on/off control - constant/pulse contact £73.00 KRP928A2S Adaptor PCB for interface to Daikin centralised control systems £129.00 KliC-DD KNX interface for Split type systems £160.00 RTD-RA Adaptor PCB for Modbus connection and/or extended system functions £156.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.CGS Condensing Unit Guard size 20-35 £209.00 UK.CGM Condensing Unit Guard size 42-71 £290.00

Accessories: Notes:i) All fan coil units standard with auto restart

after power failure

ii) All fan coils supplied as standard with infrared remote controller

iii) FTXG-JW with matt crystal white casing, FTXG-JA supplied with aluminium casing

iv) Wired controller, KliC-Di and RTD-RA options cannot be combined

v) Minimum ambient operating temperatures:

cooling heatingRXG -10°C -15°C

Page 12: Daikin AC Price List 2013

Integrated Solutions10

Split

, Sky

Air

Hea

t Pum

ps

Wall Mounted – InverterFTXS-K/G

Indoor Units FTXs20K FTXs25K FTXs35K FTXs42K FTXs50K FTXs60G FTXs71GCapacity UK Total Cooling kW 1.95 2.44 3.42 4.11 4.56 5.86 6.94

UK Sensible Cooling kW 1.65 1.82 2.56 2.85 3.14 3.87 4.65Nominal Cooling kW 2.00 2.50 3.50 4.20 5.00 6.00 7.10Nominal Heating kW 2.50 3.40 4.00 5.40 5.80 7.00 8.20

Seasonal Efficiency (EN14825) CooliNG

Energy label A+ A++ A++ A++ A++ A APdesign kW 2.00 2.50 3.50 4.20 5.00 6.00 7.10SEER 5.71 6.37 6.97 6.60 6.60 5.35 5.23Annual Energy Consumption kWh 123 137 176 223 265 393 475

Seasonal Efficiency (EN14825) HEATiNG

Energy label A++ A++ A++ A+ A+ A APdesign kW 2.30 2.50 3.60 4.00 4.60 4.80 6.50SCoP 4.75 4.63 4.71 4.09 4.10 3.75 3.50Annual Energy Consumption kWh 678 756 1071 1371 1571 1790 2593

Nominal Efficiency EER / CoP 4.65 / 4.55 4.39 / 4.52 4.17 / 4.76 3.56 / 4.12 3.55 / 4 3.02 / 3.43 3.02 / 3.22Energy label A / A A / A A / A A / A A / A B / B B / CAnnual Energy Consumption kWh 215 285 420 590 705 995 1175

Air Flow Rate High / low m3/min 8.8 / 4.7 9.1 / 5 11.2 / 5.8 11.2 / 7 11.9 / 7.4 16 / 11.3 17.2 / 11.5Dimensions Height mm 289 289 298 298 298 290 290

Width mm 780 780 900 900 900 1050 1050Depth mm 215 215 215 215 215 250 250

Weight kg 8 8 11 11 11 12 12Sound Pressure High / low dBA 40 / 24 41 / 25 45 / 29 45 / 33 46 / 34 45 / 36 46 / 37Sound Power dBA 58 58 59 59 60 61 62

outdoor Units RXs20K RXs25K RXs35K RXs42K RXs50K RXs60F RXs71FDimensions Height x Width x Depth mm 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300 770 x 900 x 320Weight kg 34 34 34 39 47 48 71Electrical Details Power Supply 1ph 1ph

Running Current A 2.30 3.10 4.10 5.70 6.30 8.78 10.49Starting Current A 2.8 3.3 4.3 6.6 6.8 9.4 11.7Max Fuse Size A 10 10 10 20 20 20 20

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 2.5Piping Connections liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2 1/4 / 5/8Pipework Maximum length m 20 20 20 20 30 30 30

Maximum Vertical Rise m 15 15 15 15 20 20 20Precharged to m 10 10 10 10 10 10 10Additional Charge g/m 20.0 20.0Holding Charge kg 1.0 1.0 1.2 1.3 1.7 1.5 2.3

Sound Pressure High dBA 46 46 48 48 48 49 52Sound Power dBA 46 46 48 48 48 49 52

Trade Fan coil Price £151.00 £162.00 £185.00 £208.00 £288.00 £294.00 £392.00Trade condensing Unit Price £427.00 £467.00 £541.00 £611.00 £680.00 £725.00 £993.00Total system Price £578.00 £629.00 £726.00 £819.00 £968.00 £1,019.00 £1,385.00

Features:• Wirelessremotecontrollerwithweeklytimer:providesa7-dayscheduletimer,enablingdailyorweeklyprogramming.Upto4actionsperdaypossible• Nightsetmode:preventssuddenchangesinroomtemperaturebygentlyadjustingthetemperaturebeforethesystemstops• Titaniumapatitephotocatalyticairpurifyingfilter:superiorpurificationanddeodorisationoftheairinsidetheroom• 2-areaintelligenteye:(25~50Kclass)airflowissenttoazoneotherthanwheretheoccupantsarelocatedatthatmoment• PresenceSensorswitchestoenergysavingmodeifroomisunoccupiedafter20mins• Powerfuloperation:activatesthemaximumairvolumefor20minutesbeforereturningtoitsoriginalsetting• Fanspeed:5fanspeedscanbeselected,hightosuperlow• Suitableformultimodelapplications• Re-useofexistingR22andR407Cpipingpossible

accessory Ref Description Trade PriceKRP980A1 Adaptor for FTXS20 & 25K needed for all control options £66.00BRC944 optional Wired Remote controller £62.00 BRCW901A03 3m connection cable for BRC944 £16.00 BRCW901A08 8m connection cable for BRC944 £21.00 KRP928A2S Adaptor PCB for interface to Daikin centralised control systems / remote on-off / constant pulse £129.00 KliC-DD KNX interface for Split type systems £160.00 RTD-RA Adaptor PCB for Modbus connection and/or extended system functions £156.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.CGS Condensing Unit Guard size 20-35 £209.00 UK.CGM Condensing Unit Guard size 42-71 £290.00

Accessories: Notes:i) All fan coil units standard with auto restart

after power failure

ii) All fan coils supplied as standard with infrared remote controller

iii) Wired controller, KliC-Di and RTD-RA options cannot be combined

iv) Minimum ambient operating temperatures:

cooling heatingRXs -10°C -15°C

Page 13: Daikin AC Price List 2013

Price List 2013 11

Split

, Sky

Air

Hea

t Pum

ps

Wall Mounted – Low InverterFTX-J/G

Indoor Units FTX20JV FTX25JV FTX35JV FTX50GV FTX60GV FTX71GVCapacity UK Total Cooling kW 1.95 2.44 3.07 4.89 5.86 6.94

UK Sensible Cooling kW 1.60 1.78 2.11 3.32 3.88 4.48Nominal Cooling kW 2.00 2.50 3.30 5.00 6.00 7.10Nominal Heating kW 2.50 2.80 3.50 5.80 7.00 8.20

Seasonal Efficiency (EN14825) CooliNG

Energy label A+ A+ A+ A+ A BPdesign kW 2.00 2.50 3.30 5.00 6.00 7.10SEER 5.63 5.63 5.66 5.63 5.10 4.93Annual Energy Consumption kWh 124 155 204 311 412 504

Seasonal Efficiency (EN14825) HEATiNG

Energy label A++ A+ A+ A+ A APdesign kW 2.20 2.40 2.80 4.60 4.80 6.50SCoP 4.67 4.50 4.14 4.08 3.74 3.45Annual Energy Consumption kWh 659 746 945 1577 1795 2634

Nominal Efficiency EER / CoP 3.64 / 4.24 3.42 / 4.06 3.37 / 3.76 3.23 / 3.63 3.02 / 3.43 3.02 / 3.22Energy label A / A A / A A / A A / A B / B B / CAnnual Energy Consumption kWh 275 365 490 775 995 1175

Air Flow Rate High / low m3/min 9.1 / 5.9 9.2 / 6 9.3 / 6.1 14.7 / 10.3 16.2 / 11.4 17.4 / 11.6Dimensions Height mm 283 283 283 290 290 290

Width mm 770 770 770 1050 1050 1050Depth mm 198 198 198 238 238 238

Weight kg 7 7 7 12 12 12Sound Pressure High / low dBA 39 / 25 40 / 26 41 / 27 43 / 34 45 / 36 46 / 37Sound Power dBA 55 56 57 62 61 62

outdoor Units RX20JV RX25JV RX35JV RX50GV RX60GV RX71GVDimensions Height x Width x Depth mm 550 x 658 x 275 735 x 825 x 300 770 x 900 x 320Weight kg 28 28 30 48 48 71Electrical Details Power Supply 1ph 1ph

Running Current A 2.49 3.49 4.99 6.83 8.78 10.49Starting Current A 2.7 3.7 5.0 7.4 9.4 TBCMax Fuse Size A 16 16 16 20 20 20

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 2.5Piping Connections liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2 1/4 / 5/8Pipework Maximum length m 15 15 15 30 30 30

Maximum Vertical Rise m 12 12 12 20 20 20Precharged to m 10 10 10 10 10 10Additional Charge g/m 20.0 20.0Holding Charge kg 0.7 0.7 1.0 1.5 1.5 1.5

Sound Pressure High dBA 46 46 48 47 49 52Sound Power dBA 46 46 48 47 49 52

Trade Fan coil Price £121.00 £133.00 £151.00 £245.00 £250.00 £334.00Trade condensing Unit Price £357.00 £381.00 £444.00 £578.00 £617.00 £886.00Total system Price £478.00 £514.00 £595.00 £823.00 £867.00 £1,220.00

Features:• Wirelessremotecontrollerwithdailytimer• Nightsetmode:preventssuddenchangesinroomtemperaturebygentlyadjustingthetemperaturebeforethesystemstops• Titaniumapatitephotocatalyticairpurifyingfilter:superiorpurificationanddeodorisationoftheairinsidetheroom• Powerfuloperation:activatesthemaximumairvolumefor20minutesbeforereturningtoitsoriginalsetting• Fanspeed:5fanspeedscanbeselected,hightosuperlow• Suitableformultimodelapplications• Re-useofexistingR22andR407Cpipingpossible

accessory Ref Description Trade PriceUK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.CGS Condensing Unit Guard size 20-35 £209.00 UK.CGM Condensing Unit Guard size 42-71 £290.00

Accessories: Notes:i) All fan coil units standard with auto restart

after power failure

ii) All fan coils supplied as standard with infrared remote controller

iii) Minimum ambient operating temperatures:

cooling heatingRX-JV +10°C -15°CRX-GV -10°C -15°C

Page 14: Daikin AC Price List 2013

Integrated Solutions12

Split

, Sky

Air

Hea

t Pum

ps

Wall Mounted – Seasonal Smart Inverter FAQ-C / RZQG

Indoor Units single Phase 3 Phase FaQ71c FaQ100c FaQ71c FaQ100c

Capacity UK Total Cooling kW 7.76 10.80 7.76 10.80UK Sensible Cooling kW 5.32 7.44 5.32 7.44Nominal Cooling kW 6.80 9.50 6.80 9.50Nominal Heating kW 7.50 10.80 7.50 10.80

Seasonal Efficiency (EN14825) CooliNG

Energy label A++ A++ A++ A++Pdesign kW 6.80 9.50 6.80 9.50SEER 6.51 6.11 6.51 6.11Annual Energy Consumption kWh 366 545 366 545

Seasonal Efficiency (EN14825) HEATiNG

Energy label A+ A+ A+ A+Pdesign kW 6.33 10.20 6.33 10.20SCoP 4.02 4.01 4.02 4.01Annual Energy Consumption kWh 2205 3560 2205 3560

Nominal Efficiency EER / CoP 3.4 / 3.7 3.62 / 3.61 3.4 / 3.7 3.62 / 3.61Energy label A / A A / A A / A A / AAnnual Energy Consumption kWh 1000 1315 1000 1315

Air Flow Rate High / low m3/min 18 / 14 26 / 19 18 / 14 26 / 19Dimensions Height mm 290 340 290 340

Width mm 1050 1200 1050 1200Depth mm 238 240 238 240

Weight kg 13 17 13 17Sound Pressure High / low dBA 45 / 40 49 / 41 45 / 40 49 / 41Sound Power dBA 61 41 61 41

outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG71L8Y1 RZQG100L8Y1Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 78 102 80 101Electrical Details Power Supply 1ph 3ph

Running Current A 9.25 12.16 3.07 4.04Starting Current A 4 4 4 4Max Fuse Size A 20 32 16 20

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum length m 50 75 50 75

Maximum Vertical Rise m 30 30 30 30Precharged to m 30 30 30 30Additional Charge g/m Refer to installation Manual Refer to installation ManualHolding Charge kg 2.9 4.0 2.9 4.0

Sound Pressure High dBA 48 50 48 50Sound Power dBA 48 50 48 50

Trade Fan coil Price £783.00 £846.00 £783.00 £846.00Trade condensing Unit Price £1,168.00 £1,484.00 £1,203.00 £1,553.00Total system Price £1,951.00 £2,330.00 £1,986.00 £2,399.00

Features:• Fanspeed:3fanspeedsavailableonallcapacities• Automaticairflowvolumecontrolsetsfanspeedbasedondifferencebetweensetandroomtemperatures• Dryprogramme:Daikin’sspecialdryprogrammereduceshumidityintheroomswithoutvariationsininternaltemperature• Comms,computerandserverroomcoolingpossiblewithEDPsetting(SeasonalSmart)• Selectableevaporating&condensingtemperatureforgreateroperatingefficiencyandapplicationflexibility(SeasonalSmart)• DIIInetcompatibilityasstandard• SeasonallyEfficientInverterTechnologygivesupto25%betterefficiencythaninvertertechnology• Re-useofexistingR22andR407Cpipingpossible.(SeeR22Replacementleaflet)• SuitableforTwin,TripleandDoubleTwinapplications

accessory Ref Description Trade PriceBRC7EB518 Wireless remote controller £132.00KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £89.00 RTD-NET/UK.FB2 Modbus interface PCB for Sky Air and VRV £185.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, lead lag control and heating interlock £229.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV Poa KliC-Di KNX interface for Sky Air and VRV systems £181.00 KRCS01-4 Remote room mounted temperature sensor £46.00 K.RSS Wireless room mounted temperature sensor and receiver £91.00 RS-SE Service and Configuration Tool for K.RSS £87.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £45.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £57.00 UK.CGM Condensing Unit Guard size 42-71 £290.00 UK.CGl Condensing Unit Guard size 100-140 including RXYSQ £347.00

Accessories: Notes:i) BRC7EB518 Trade price will be reduced by

£74.00 if ordered at the same time as the fan coil unit

ii) All fan coil units standard with auto restart after power failure

iii) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock

iv) Minimum ambient operating temperatures:

cooling heatingRZQG -15°C -20°CRZQsG -5°C -15°C

Page 15: Daikin AC Price List 2013

Price List 2013 13

Split

, Sky

Air

Hea

t Pum

ps

Wall Mounted – Seasonal Classic Inverter FAQ-C / RZQSG

Indoor Units single Phase 3 PhaseFaQ71c FaQ100c FaQ100c

Capacity UK Total Cooling kW 7.28 10.80 10.80UK Sensible Cooling kW 4.99 7.44 7.44Nominal Cooling kW 6.80 9.50 9.50Nominal Heating kW 7.50 10.80 10.80

Seasonal Efficiency (EN14825) CooliNG

Energy label A+ A+ A+ Pdesign kW 6.80 9.50 9.50SEER 6.05 5.61 5.61Annual Energy Consumption kWh 394 593 593

Seasonal Efficiency (EN14825) HEATiNG

Energy label A+ A+ A+Pdesign kW 6.00 6.81 6.81SCoP 3.90 4.01 4.01Annual Energy Consumption kWh 2155 2376 2376

Nominal Efficiency EER / CoP 3.21 / 3.61 3.01 / 3.41 3.01 / 3.41Energy label A / A B / B B / BAnnual Energy Consumption kWh 1059 1580 1580

Air Flow Rate High / low m3/min 18 / 14 26 / 19 26 / 19Dimensions Height mm 290 340 340

Width mm 1050 1200 1200Depth mm 238 240 240

Weight kg 13 17 17Sound Pressure High / low dBA 45 / 40 49 / 41 49 / 45Sound Power dBA 61 65 41

outdoor Units RZQsG71L3V1 RZQsG100L8V1 RZQsG100L8Y1Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 990 x 940 x 320Weight kg 67 81 82Electrical Details Power Supply 1ph 3ph

Running Current A 9.22 13.74 4.83Starting Current A 4 4 4Max Fuse Size A 20 32 20

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum length m 30 50 50

Maximum Vertical Rise m 15 30 30Precharged to m 30 30 30Additional Charge g/m Refer to installation Manual Refer to installation ManualHolding Charge kg 2.75 2.9 2.9

Sound Pressure High dBA 49 53 53Sound Power dBA 49 53 53

Trade Fan coil Price £783.00 £846.00 £846.00Trade condensing Unit Price £864.00 £1,196.00 £1,232.00Total system Price £1,647.00 £2,042.00 £2,078.00

Page 16: Daikin AC Price List 2013

Integrated Solutions14

Split

, Sky

Air

Hea

t Pum

ps

Floor Mounted – InverterNexura

Indoor Units FVXG25K FVXG35K FVXG50KCapacity UK Total Cooling kW 2.44 3.42 4.81

UK Sensible Cooling kW 1.93 2.37 3.17Nominal Cooling kW 2.50 3.50 5.00Nominal Heating kW 3.40 4.50 5.80

Seasonal Efficiency (EN14825) CooliNG

Energy label A++ A++ APdesign kW 2.50 3.50 5.00SEER 6.46 6.33 5.31Annual Energy Consumption kWh 135 194 330

Seasonal Efficiency (EN14825) HEATiNG

Energy label A+ A APdesign kW 2.80 3.10 4.60SCoP 4.47 3.87 4.08Annual Energy Consumption kWh 877 1122 1577

Nominal Efficiency EER / CoP 4.55 / 4.36 3.68 / 3.72 3.29 / 3.67Energy label A / A A / A A / AAnnual Energy Consumption kWh 275 475 760

Air Flow Rate High / low m3/min 8.9 / 5.3 9.1 / 5.3 10.6 / 7.3Dimensions Height mm 600 600 600

Width mm 950 950 950Depth mm 215 215 215

Weight kg 14 14 14Sound Pressure High / low dBA 38 / 26 39 / 27 44 / 36Sound Power dBA 54 55 56

outdoor Units RXG25K RXG35K RXG50KDimensions Height x Width x Depth mm 550 x 765 x 285 735 x 825 x 300Weight kg 34 34 48Electrical Details Power Supply 1ph

Running Current A 2.90 4.60 6.70Starting Current A 4.1 6.0 7.3Max Fuse Size A 10 10 20

interconnection Wiring Core / Cable size 3+E / 1.5Piping Connections liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2Pipework Maximum length m 20 20 30

Maximum Vertical Rise m 15 15 20Precharged to m 10 10 10Additional Charge g/m 20.0Holding Charge kg 1.1 1.1 1.6

Sound Pressure High dBA 46 48 48Sound Power dBA 46 48 48

Trade Fan coil Price £619.00 £666.00 £729.00Trade condensing Unit Price £494.00 £574.00 £918.00Total system Price £1,113.00 £1,240.00 £1,647.00

Features:• RadiantHeatpanelprovidesradiator-likewarmingatthetouchofabutton• Energyefficientunits:fullrangeAclassenergylabels• Wirelessremotecontrollerprovidesa7-dayscheduletimer,enablingtheusertoprogramtheairconditioningdailyorweekly,withupto4actionsperday• Titaniumapatitephotocatalyticairpurifyingfilter:superiorpurificationanddeodorisationoftheairinsidetheroom• Powerfuloperation:activatesthemaximumairvolumefor20minutesbeforereturningtoitsoriginalsetting• Extremelyquietinoperation:downto19dBAsoundpressurelevel• Nightsetmode:preventsanysuddenchangeinroomtemperaturebygentlyraising/loweringthetemperaturebeforethesystemstops,

so you can sleep more comfortably• Verticalautoswingsystemautomaticallymakesthelouversmoveupanddown,creatinganevendistributionofairthroughtheroomto

ensure a harmonized temperature• Flexibleinstallation:Canbeinstalledagainstawall,recessedorstandingonthefloor(installationlegrequired,seeaccessorieslist).

Ideal for installation beneath a window• Suitableformultimodelapplications• Re-useofexistingR22andR407pipingpossible

accessory Ref Description Trade PriceBRC944 optional Wired Remote controller £62.00 BRCW901A03 3m connection cable for BRC944 £16.00 BRCW901A08 8m connection cable for BRC944 £21.00 KRP413A1S Adaptor PCB for remote on/off control - constant/pulse contact £73.00 KRP928A2S Adaptor PCB for interface to Daikin centralised control systems £129.00 KliC-DD KNX interface for Split type systems £160.00 RTD-RA Adaptor PCB for Modbus connection and/or extended system functions £156.00 BKS028 leg for floor-standing installation £385.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.CGS Condensing Unit Guard size 20-35 £209.00 UK.CGM Condensing Unit Guard size 42-71 £290.00

Accessories: Notes:i) All fan coil units standard with auto restart

after power failure

ii) All fan coils supplied as standard with infrared remote controller

iii) Wired controller, KliC-Di and RTD-RA options cannot be combined

iv) Minimum ambient operating temperatures:

cooling heatingRXG -10°C -15°C

Page 17: Daikin AC Price List 2013

Price List 2013 15

Split

, Sky

Air

Hea

t Pum

ps

Floor Mounted – InverterFVXS

Indoor Units FVXs25F FVXs35F FVXs50FCapacity UK Total Cooling kW 2.44 3.42 4.89

UK Sensible Cooling kW 1.87 2.34 3.21Nominal Cooling kW 2.50 3.50 5.00Nominal Heating kW 3.40 4.50 5.80

Seasonal Efficiency (EN14825) CooliNG

Energy label B B APdesign kW 2.50 3.50 5.00SEER 4.71 4.93 5.53Annual Energy Consumption kWh 186 248 317

Seasonal Efficiency (EN14825) HEATiNG

Energy label A+ A APdesign kW 2.60 2.90 4.80SCoP 4.38 3.83 3.62Annual Energy Consumption kWh 830 1060 1853

Nominal Efficiency EER / CoP 4.39 / 4.3 3.43 / 3.69 3.23 / 3.63Energy label A / A A / A A / AAnnual Energy Consumption kWh 285 510 775

Air Flow Rate High / low m3/min 8.2 / 4.8 8.5 / 4.9 10.7 / 7.8Dimensions Height mm 600 600 600

Width mm 700 700 700Depth mm 210 210 210

Weight kg 14 14 14Sound Pressure High / low dBA 38 / 26 39 / 27 44 / 36Sound Power High dBA 54 55 56

outdoor Units RXs25K RXs35K RXs50KDimensions Height x Width x Depth mm 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300Weight kg 34 34 47Electrical Details Power Supply 1ph

Running Current A 3.30 4.70 6.80Starting Current A 3.3 4.3 6.8Max Fuse Size A 10 10 20

interconnection Wiring Core / Cable size 3+E / 1.5Piping Connections liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2Pipework Maximum length m 20 20 30

Maximum Vertical Rise m 15 15 20Precharged to m 10 10 10Additional Charge g/m 20.0Holding Charge kg 1.0 1.2 1.7

Sound Pressure High dBA 46 48 48Sound Power High dBA 46 48 48

Trade Fan coil Price £513.00 £553.00 £604.00Trade condensing Unit Price £467.00 £541.00 £680.00Total system Price £980.00 £1,094.00 £1,284.00

Features:• Extremelyquiet,energyefficientandcanbeinstalledagainstthewallorrecessed• Wirelessremotecontrollerwithweeklytimer:providesa7-dayscheduletimer,enablingdailyorweeklyprogramming.Upto4actionsperdaypossible• Nightsetmode:preventsanysuddenchangeinroomtemperaturebygentlyraising/loweringthetemperaturebeforethesystemstops• Powerfuloperation:activatesthemaximumairvolumefor20minutesbeforereturningtoitsoriginalsetting• Titaniumapatitephotocatalyticairpurifyingfilter:superiorpurificationanddeodorisationoftheairinsidetheroom• Dryprogramme:Daikin’sspecialdryprogrammereduceshumidityintheroomswithoutvariationsininternaltemperature• Suitableformultimodelapplications• Re-useofexistingR22andR407Cpipingpossible

accessory Ref Description Trade PriceKRP413A1S Adaptor PCB for remote on/off control - constant/pulse contact £73.00 KRP928A2S Adaptor PCB for interface to Daikin centralised control systems £129.00 KliC-DD KNX interface for Split type systems £160.00 RTD-RA Adaptor PCB for Modbus connection and/or extended system functions £156.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.CGS Condensing Unit Guard size 20-35 £209.00 UK.CGM Condensing Unit Guard size 42-71 £290.00

Accessories: Notes:i) All fan coil units standard with auto restart

after power failure

ii) All fan coils supplied as standard with infrared remote controller

iii) Wired controller, KliC-Di and RTD-RA options cannot be combined

iv) Minimum ambient operating temperatures:

cooling heatingRXs -10°C -15°C

Page 18: Daikin AC Price List 2013

Integrated Solutions16

Split

, Sky

Air

Hea

t Pum

ps

Floor Mounted – Seasonal Smart InverterFVQ-C / RZQG

Indoor Units single Phase 3 Phase FVQ71c FVQ100c FVQ125c FVQ140c FVQ71c FVQ100c FVQ125c FVQ140c

Capacity UK Total Cooling kW 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90UK Sensible Cooling kW 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) CooliNG

Energy label A++ A+ A+ - A++ A+ A+ -Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -SEER 6.31 5.61 5.61 - 6.31 5.61 5.61 -Annual Energy Consumption kWh 378 593 749 - 378 593 749 -

Seasonal Efficiency (EN14825) HEATiNG

Energy label A+ A+ A - A+ A+ A -Pdesign kW 6.33 11.30 11.30 - 6.33 11.30 11.30 -SCoP 4.05 4.20 3.87 - 4.05 4.20 3.87 -Annual Energy Consumption kWh 2189 3769 4090 - 2189 3769 4090 -

Nominal Efficiency EER / CoP 3.37 / 3.64 3.81 / 4.14 3.21 / 3.7 3.21 / 3.61 3.37 / 3.64 3.81 / 4.14 3.21 / 3.7 3.21 / 3.61Energy label A / A A / A A / A A / A A / A A / A A / A A / AAnnual Energy Consumption kWh 1010 1245 1870 2085 1010 1245 1870 2085

Air Flow Rate High / low m3/min 18 / 14 28 / 25 28 / 26 30 / 28 18 / 14 28 / 25 28 / 26 30 / 28Dimensions Height mm 1850 1850 1850 1850 1850 1850 1850 1850

Width mm 600 600 600 600 600 600 600 600Depth mm 270 350 350 350 270 350 350 350

Weight kg 39 47 47 47 39 47 47 47Sound Pressure High / low dBA 43 / 38 50 / 44 51 / 46 53 / 48 43 / 38 50 / 44 51 / 46 53 / 48Sound Power dBA 55 62 63 65 55 62 63 65

outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1Dimensions Height x Width x Depth mm 990 x 940

x 3201430 x 940

x 3201430 x 940

x 3201430 x 940

x 320990 x 940

x 3201430 x 940

x 3201430 x 940

x 3201430 x 940

x 320Weight kg 78 102 102 102 80 101 101 101Electrical Details Power Supply 1ph 3ph

Running Current A 9.34 11.52 17.30 19.29 3.11 3.83 5.75 6.41Starting Current A 4 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 16 20 20 20

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum length m 50 75 75 75 50 75 75 75

Maximum Vertical Rise m 30 30 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30 30Additional Charge g/m Refer to installation Manual Refer to installation ManualHolding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0

Sound Pressure High dBA 48 50 51 52 48 50 51 52Sound Power dBA 48 50 51 52 48 50 51 52

Trade Fan coil Price £1,047.00 £1,150.00 £1,270.00 £1,366.00 £1,047.00 £1,150.00 £1,270.00 £1,366.00Trade condensing Unit Price £1,168.00 £1,484.00 £1,633.00 £1,864.00 £1,203.00 £1,553.00 £1,709.00 £1,963.00Total system Price £2,215.00 £2,634.00 £2,903.00 £3,230.00 £2,250.00 £2,703.00 £2,979.00 £3,329.00

Features:• SeasonallyEfficientInverterTechnologygivesupto25%betterefficiencythanInverterTechnology• Verticalairflowpatterncanbeadjustedmanuallytomatchrequirementsindifferentsizedinteriorsorirregularlyshapedrooms• AwiredBRC1E52Aremotecontrollerismountedonthefrontoftheunit(standard)• Controllablehorizontalair-blowpatterns,viaremotecontrol• Veryefficientforuseinroomswithhighceilings• Fanspeed:2fanspeedscanbeselected,highorlow• Re-useofexistingR22andR407Cpipingpossible• Comms,computerandserverroomcoolingpossiblewithEDPsetting(SeasonalSmart)• Selectableevaporating&condensingtemperatureforgreateroperatingefficiency(SeasonalSmart)• DIIInetcompatibilityasstandard

accessory Ref Description Trade PriceKRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £89.00 RTD-NET/UK.FB2 Modbus interface PCB for Sky Air and VRV £185.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, lead lag control and heating interlock £229.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV Poa KliC-Di KNX interface for Sky Air and VRV systems £181.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £45.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £57.00 UK.CGM Condensing Unit Guard size 42-71 £290.00 UK.CGl Condensing Unit Guard size 100-140 £347.00

Accessories: Notes:i) All fan coil units standard with auto restart

after power failure

ii) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock

iii) Minimum ambient operating temperatures:

cooling heatingRZQG -15°C -20°CRZQsG -5°C -15°C

Page 19: Daikin AC Price List 2013

Price List 2013 17

Split

, Sky

Air

Hea

t Pum

ps

Floor Mounted – Seasonal Classic InverterFVQ-C / RZQSG

Indoor Units single Phase 3 PhaseFVQ71c FVQ100c FVQ125c FVQ140c FVQ100c FVQ125c FVQ140c

Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) CooliNG

Energy label A A A - A A -Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -SEER 5.50 5.50 5.50 - 5.50 5.50 -Annual Energy Consumption kWh 433 605 764 - 605 764 -

Seasonal Efficiency (EN14825) HEATiNG

Energy label A A+ A+ - A+ A+ -Pdesign kW 6.33 7.60 7.60 - 7.60 7.60 -SCoP 3.86 4.01 4.21 - 4.01 4.21 -Annual Energy Consumption kWh 2297 2553 2527 - 2553 2527 -

Nominal Efficiency EER / CoP 3.21 / 3.61 3.21 / 3.61 2.81 / 3.41 3.01 / 3.41 3.21 / 3.61 2.81 / 3.41 3.01 / 3.41Energy label A / A A / A C / B B / B A / A C / B B / BAnnual Energy Consumption kWh 1059 1480 2135 2225 1480 2135 2225

Air Flow Rate High / low m3/min 18 / 14 28 / 25 28 / 26 30 / 28 28 / 25 28 / 26 30 / 28Dimensions Height mm 1850 1850 1850 1850 1850 1850 1850

Width mm 600 600 600 600 600 600 600Depth mm 270 350 350 350 350 350 350

Weight kg 39 47 47 47 47 47 47Sound Pressure High / low dBA 43 / 38 50 / 44 51 / 46 53 / 48 50 / 44 51 / 46 53 / 48Sound Power dBA 55 62 63 65 62 63 65

outdoor Units RZQsG71L3V1 RZQsG100L8V1 RZQsG125L8V1 RZQsG140LV1 RZQsG100L8Y1 RZQsG125L8Y1 RZQsG140LY1Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 67 81 102 82 101Electrical Details Power Supply 1ph 3ph

Running Current A 9.22 12.87 18.57 19.35 4.52 6.53 6.80Starting Current A 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 20 20 20

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum length m 30 50 50 50 50 50 50

Maximum Vertical Rise m 15 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30Additional Charge g/m Refer to installation Manual Refer to installation ManualHolding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0

Sound Pressure High dBA 49 53 54 53 53 54 53Sound Power dBA 49 53 54 53 53 54 53

Trade Fan coil Price £1,047.00 £1,150.00 £1,270.00 £1,366.00 £1,150.00 £1,270.00 £1,366.00Trade condensing Unit Price £864.00 £1,196.00 £1,312.00 £1,461.00 £1,232.00 £1,351.00 £1,505.00Total system Price £1,911.00 £2,346.00 £2,582.00 £2,827.00 £2,382.00 £2,621.00 £2,871.00

Page 20: Daikin AC Price List 2013

Integrated Solutions18

Split

, Sky

Air

Hea

t Pum

ps

Floor or Ceiling Mounted – Inverter FLXS

Indoor Units FLXs25B FLXs35B FLXs50BCapacity UK Total Cooling kW 2.44 3.34 4.82

UK Sensible Cooling kW 1.65 2.14 3.16Nominal Cooling kW 2.50 3.50 4.90Nominal Heating kW 3.40 4.00 6.10

Seasonal Efficiency (EN14825) CooliNG

Energy label C C BPdesign kW 2.50 3.50 4.90SEER 4.46 4.49 5.09Annual Energy Consumption kWh 196 273 337

Seasonal Efficiency (EN14825) HEATiNG

Energy label A A APdesign kW 2.80 2.90 4.50SCoP 3.63 3.42 3.68Annual Energy Consumption kWh 1080 1186 1708

Nominal Efficiency EER / CoP 3.85 / 3.47 3.1 / 3.25 2.85 / 3.35Energy label A / B B / C C / CAnnual Energy Consumption kWh 325 565 860

Air Flow Rate High / low m3/min 7.6 / 6 8.6 / 6.6 11.4 / 8.5Dimensions Height mm 490 490 490

Width mm 1050 1050 1050Depth mm 200 200 200

Weight kg 16 16 17Sound Pressure High / low dBA 37 / 31 38 / 32 47 / 39Sound Power dBA 53 54 63

outdoor Units RXs25K RXs35K RXs50KDimensions Height x Width x Depth mm 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300Weight kg 34 34 47Electrical Details Power Supply 1ph

Running Current A 3.60 5.10 7.60Starting Current A 3.3 4.3 6.8Max Fuse Size A 10 10 20

interconnection Wiring Core / Cable size 3+E / 1.5Piping Connections liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2Pipework Maximum length m 20 20 30

Maximum Vertical Rise m 15 15 20Precharged to m 10 10 10Additional Charge g/m 20.0Holding Charge kg 1.0 1.2 1.7

Sound Pressure High dBA 46 48 48Sound Power dBA 46 48 48

Trade Fan coil Price £369.00 £415.00 £450.00Trade condensing Unit Price £467.00 £541.00 £680.00Total system Price £836.00 £956.00 £1,130.00

Features:• CanbeinstalledEITHERasceilingmountedORwallunit• Verticalautoswing:flapsautomaticallyswingupanddowntoensureefficientairandtemperaturedistributioninbothfloorlevelandceiling

suspended installation• HomeLeavesettingmaintainspre-settemperatureduringperiodsofextendedabsence• Nightsetmode:preventsanysuddenchangeinroomtemperaturebygentlyraising/loweringthetemperaturebeforethesystemstops• Fanspeed:5fanspeedscanbeselected,hightosuperlow• Suitableformultimodelapplications• Re-useofexistingR22andR407Cpipingpossible

accessory Ref Description Trade PriceKRP413A1S Adaptor PCB for remote on/off control - constant/pulse contact £73.00 KRP928A2S Adaptor PCB for interface to Daikin centralised control systems £129.00 KliC-DD KNX interface for Split type systems £160.00 RTD-RA Adaptor PCB for Modbus connection and/or extended system functions £156.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.CGS Condensing Unit Guard size 20-35 £209.00 UK.CGM Condensing Unit Guard size 42-71 £290.00

Accessories: Notes:i) All fan coil units standard with auto restart

after power failure

ii) All fan coils supplied as standard with infrared remote controller

iii) Wired controller, KliC-Di and RTD-RA options cannot be combined

iv) Minimum ambient operating temperatures:

cooling heatingRXs -10°C -15°C

Page 21: Daikin AC Price List 2013

Price List 2013 19

Split

, Sky

Air

Hea

t Pum

ps

accessory Ref Description Trade PriceBRC7G53 Wireless remote controller £149.00 EKRoRo4 Remote on/off control interface kit £15.00 KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £89.00 RTD-NET/UK.FB2 Modbus interface PCB for Sky Air and VRV £185.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, lead lag control and heating interlock £229.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV Poa KliC-DD KNX interface for Sky Air and VRV systems £160.00 KRCS01-1 Remote room mounted temperature sensor £45.00 K.RSS Wireless room mounted temperature sensor and receiver £91.00 RS-SE Service and Configuration Tool for K.RSS £87.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £45.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £57.00 UK.CGS Condensing Unit Guard size 20-35 £209.00 UK.CGM Condensing Unit Guard size 42-71 £290.00 UK.CGl Condensing Unit Guard size 100-140 including RXYSQ £347.00 KDDQ50A140 Fresh Air intake Kit (Max 10%) TBc

Ceiling Suspended – InverterFHQ-C

Indoor Units FhQ35c FhQ50c FhQ60cCapacity UK Total Cooling kW 3.32 4.89 5.62

UK Sensible Cooling kW 2.58 3.21 4.07Nominal Cooling kW 3.40 5.00 5.70Nominal Heating kW 4.00 6.00 7.20

Seasonal Efficiency (EN14825)CooliNG

Energy label B A APdesign kW 3.40 5.00 5.70SEER 4.89 5.48 5.54Annual Energy Consumption kWh 243 320 360

Seasonal Efficiency (EN14825)HEATiNG

Energy label A A APdesign kW 3.10 4.35 5.07SCoP 3.98 3.74 3.50Annual Energy Consumption kWh 1090 1627 2026

Nominal Efficiency EER / CoP 3.58 / 3.96 3.18 / 3.35 3.26 / 3.32Energy label A / B A / C A / CAnnual Energy Consumption kWh 475 785 875

Air Flow Rate High / low m3/min 14 / 10 15 / 10 19.5 / 15Dimensions Height mm 235 235 235

Width mm 960 960 1270Depth mm 690 690 690

Weight kg 24 25 31Sound Pressure High / low dBA 36 / 32 37 / 33 37 / 33Sound Power dBA 53 54 54

outdoor Units RXs35K RXs50K RXs60FDimensions Height x Width x Depth mm 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300Weight kg 34 47 48Electrical Details Power Supply 1ph

Running Current A 5.12* 8.28* 9.68*Starting Current A 4.3 6.8 9.4Max Fuse Size A 10 20 20

interconnection Wiring Core / Cable size 3+E / 1.5Piping Connections liquid / Gas inches 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2Pipework Maximum length m 20 30 30

Maximum Vertical Rise m 15 20 20Precharged to m 10 10 10Additional Charge g/m 20.0Holding Charge kg 1.2 1.7 1.5

Sound Pressure High dBA 48 48 49Sound Power dBA 48 48 49

Trade Fan coil Price £696.00 £754.00 £828.00Trade condensing Unit Price £541.00 £680.00 £725.00Total system Price £1,237.00 £1,434.00 £1,553.00

Features:• Suitableforceilingheightsofupto3.8mwithoutlossofcapacity• Verticalauto-swingfunctionofflapsensuresefficientairandtemperaturedistribution• Forcedoff:Theoptionalforcedofffeatureenablestheunittoswitchoffautomatically,forexamplewhenawindowisopened• Re-useofexistingR22andR407Cpipingpossible• SuitableforTwin,TripleandDoubleTwinapplications

Accessories: Notes:i) BRC7G53 Trade price will be reduced by

£74.00 if ordered at the same time as the fan coil unit in place of the BRC1E52A

ii) All fan coil units standard with auto restart after power failure

iii) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock

iv) Data marked with * is preliminary

v) Minimum ambient operating temperatures:

cooling heatingRXs -10°C -15°C

Page 22: Daikin AC Price List 2013

Integrated Solutions20

Split

, Sky

Air

Hea

t Pum

ps

Ceiling Suspended – Seasonal Smart InverterFHQ-C Seasonal Smart

Indoor Units single Phase 3 Phase FhQ71c FhQ100c FhQ125c FhQ140c FhQ71c FhQ100c FhQ125c FhQ140c

Capacity UK Total Cooling kW 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90UK Sensible Cooling kW 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) CooliNG

Energy label A++ A+ A+ - A++ A+ A+ -Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -SEER 6.95 6.11 6.01 - 6.95 6.11 6.01 -Annual Energy Consumption kWh 343 545 699 - 343 545 699 -

Seasonal Efficiency (EN14825) HEATiNG

Energy label A+ A++ A+ - A+ A++ A+ -Pdesign kW 7.60 11.30 14.13 - 7.60 11.30 14.13 -SCoP 4.32 4.61 4.23 - 4.32 4.61 4.23 -Annual Energy Consumption kWh 2462 3433 4677 - 2462 3433 4677 -

Nominal Efficiency EER / CoP 3.82 / 4.13 4.13 / 4.42 3.52 / 3.89 3.31 / 3.63 3.82 / 4.13 4.13 / 4.42 3.52 / 3.89 3.31 / 3.63Energy label A / A A / A A / A A / A A / A A / A A / A A / AAnnual Energy Consumption kWh 890 1245 1790 2025 890 1245 1790 2025

Air Flow Rate High / low m3/min 20.5 / 14 28 / 20 31 / 23 34 / 24 20.5 / 14 28 / 20 31 / 23 34 / 24Dimensions Height mm 235 235 235 235 235 235 235 235

Width mm 1270 1590 1590 1590 1270 1590 1590 1590Depth mm 690 690 690 690 690 690 690 690

Weight kg 32 38 38 38 32 38 38 38Sound Pressure High / low dBA 38 / 34 42 / 34 44 / 37 46 / 38 38 / 34 42 / 34 44 / 37 46 / 38Sound Power dBA 55* 60 62 64 55* 60 62 64

outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 78 102 80 101Electrical Details Power Supply 1ph 3ph

Running Current A 8.23 11.52 16.56 18.73 2.74 3.83 5.50 6.23Starting Current A 4 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 16 20 20 20

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum length m 50 75 75 75 50 75 75 75

Maximum Vertical Rise m 30 30 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30 30Additional Charge g/m Refer to installation Manual Refer to installation ManualHolding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0

Sound Pressure High dBA 48 50 51 52 48 50 51 52Sound Power dBA 48 50 51 52 48 50 51 52

Trade Fan coil Price £969.00 £1,030.00 £1,289.00 £1,532.00 £969.00 £1,030.00 £1,289.00 £1,532.00Trade condensing Unit Price £1,168.00 £1,484.00 £1,633.00 £1,864.00 £1,203.00 £1,553.00 £1,709.00 £1,963.00Total system Price £2,137.00 £2,514.00 £2,922.00 £3,396.00 £2,172.00 £2,583.00 £2,998.00 £3,495.00

Features:• Suitableforceilingheightsofupto3.8mwithoutlossofcapacity• SeasonallyEfficientInverterTechnologygivesupto25%betterefficiency

than inverter technology• Forcedoff:Theoptionalforcedoffenablestheunittoswitchoff

automatically, for example when a window is opened• Re-useofexistingR22andR407Cpipingpossible

• SuitableforTwin,TripleandDoubleTwinapplications• Comms,computerandserverroomcoolingpossiblewith

EDP setting (Seasonal Smart)• Selectableevaporating&condensingtemperatureforgreater

operating efficiency (Seasonal Smart)• DIIInetcompatibilityasstandard

accessory Ref Description Trade PriceBRC7G53 Wireless remote controller £149.00EKRoRo4 Remote on/off control interface kit £15.00 KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £89.00 RTD-NET/UK.FB2 Modbus interface PCB for Sky Air and VRV £185.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, lead lag control and heating interlock £229.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV Poa KliC-Di KNX interface for Sky Air and VRV systems £181.00 KRCS01-1 Remote room mounted temperature sensor £45.00 K.RSS Wireless room mounted temperature sensor and receiver £91.00 RS-SE Service and Configuration Tool for K.RSS £87.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £45.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £57.00 UK.CGS Condensing Unit Guard size 20-35 £209.00 UK.CGM Condensing Unit Guard size 42-71 £290.00 UK.CGl Condensing Unit Guard size 100-140 including RXYSQ £347.00 KDDQ50A140 Fresh Air intake Kit (Max 10%) TBc

Accessories: Notes:i) BRC7G53 Trade price will be reduced by

£74.00 if ordered at the same time as the fan coil unit in place of the BRC1E52A

ii) All fan coil units standard with auto restart after power failure

iii) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock

iv) Minimum ambient operating temperatures:

cooling heatingRZQG -15°C -20°CRZQsG -5°C -15°CRXs -10°C -15°C

Page 23: Daikin AC Price List 2013

Price List 2013 21

Split

, Sky

Air

Hea

t Pum

ps

Ceiling Suspended – Seasonal Classic InverterFHQ-C Seasonal Classic

Indoor Units single Phase 3 PhaseFhQ71c FhQ100c FhQ125c FhQ140c FhQ100c FhQ125c FhQ140c

Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) CooliNG

Energy label A+ A+ A+ - A+ A+ -Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -SEER 5.61 5.61 5.61 - 5.61 5.61 -Annual Energy Consumption kWh 425 593 749 - 593 749 -

Seasonal Efficiency (EN14825) HEATiNG

Energy label A A A+ - A A+ -Pdesign kW 7.60 7.60 7.60 - 7.60 7.60 -SCoP 3.90 3.91 4.01 - 3.91 4.01 -Annual Energy Consumption kWh 2727 2720 2653 - 2720 2653 -

Nominal Efficiency EER / CoP 3.46 / 4 3.21 / 3.61 2.89 / 3.62 3.01 / 3.41 3.21 / 3.61 2.89 / 3.62 3.01 / 3.41Energy label A / A A / A C / A B / B A / A C / A B / BAnnual Energy Consumption kWh 983 1480 2075 2225 1480* 2075* 2225*

Air Flow Rate High / low m3/min 20.5 / 14 28 / 20 31 / 23 34 / 24 28 / 20 31 / 23 34 / 24Dimensions Height mm 235 235 235 235 235 235 235

Width mm 1270 1590 1590 1590 1590 1590 1590Depth mm 690 690 690 690 690 690 690

Weight kg 32 38 38 38 38 38 38Sound Pressure High / low dBA 38 / 34 42 / 34 44 / 37 46 / 38 42 / 34 44 / 37 46 / 38Sound Power dBA 55 60 62 64 60 62 64

outdoor Units RZQsG71L3V1 RZQsG100L8V1 RZQsG125L8V1 RZQsG140LV1 RZQsG100L8Y1 RZQsG125L8Y1 RZQsG140LY1Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 67 81 102 82 101Electrical Details Power Supply 1ph 3ph

Running Current A 8.57 12.87 18.04 19.35 4.52 6.34 6.80Starting Current A 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 20 20 20

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum length m 30 50 50 50 50 50 50

Maximum Vertical Rise m 15 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30Additional Charge g/m Refer to installation Manual Refer to installation ManualHolding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0

Sound Pressure High dBA 49 53 54 53 53 54 53Sound Power dBA 49 53 54 53 53 54 53

Trade Fan coil Price £969.00 £1,030.00 £1,289.00 £1,532.00 £1,030.00 £1,289.00 £1,532.00Trade condensing Unit Price £864.00 £1,196.00 £1,312.00 £1,461.00 £1,232.00 £1,351.00 £1,505.00Total system Price £1,833.00 £2,226.00 £2,601.00 £2,993.00 £2,262.00 £2,640.00 £3,037.00

Page 24: Daikin AC Price List 2013

Integrated Solutions22

Split

, Sky

Air

Hea

t Pum

ps

your comfort. our world.

Designed with the installer in mind, the Fully Flat Cassette fits flush within a standard European ceiling panel to reduce installation time. Daikin’s market leading technology with intelligent sensors and the ability to easily reconfigure the air flow makes set up extremely simple, while delivering perfect comfort to your customers.

& Geniusin one

Design

“Leading edge design in tune with time“

FFQ50C+RXS50K=A+/A+

Page 25: Daikin AC Price List 2013

Price List 2013 23

Split

, Sky

Air

Hea

t Pum

ps

600x600 Fully Flat CassetteFFQ (FFQ-C Series coming summer 2013. FFQ-B9V series available until then)

Features:• Installedintosuspendedceilinggridswithoutcuttingsurroundingtiles• HomeLeavesettingmaintainspre-settemperatureduringperiodsofextendedabsence• Dryprogramme:Daikin’sspecialdryprogrammereduceshumidityintheroomswithoutvariationsininternaltemperature• Verticalauto-swingfunction:flapsautomaticallyswingupanddowntoensureefficientairandtemperaturedistributionwhichalsopreventsceilingsoiling• 3fanspeedscanbeselected:high,mediumandlow• SuitableforTwin,TripleandDoubleTwinapplications.Alsosuitableformultimodelapplications• Re-useofexistingR22andR407Cpipingpossible

accessory Ref Description Trade PriceBYCQ60W Fully Flat decoration panel - white £194.00BYCQ60S Fully Flat decoration panel - silver £194.00BYCQ60B2 FFQ-B9V style decoration panel £139.00BRYQ60AW integral PiR sensor for White Fully Flat decoration panel. Enables energy saving functions £97.00BRYQ60AS integral PiR sensor for Silver Fully Flat decoration panel. Enables energy saving functions £97.00BRC7E530 Wireless infrared controller £149.00BRC7F530W Wireless infrared controller - white finish to match white deco-panel £149.00BRC7F530S Wireless infrared controller - silver finish to match silver deco-panel £149.00EKRoRo2 Remote on/off control interface kit £28.00KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £89.00KRP1B57/UK.FB2 Adaptor PCB for interlock to fresh air fan £97.00RTD-NET/UK.FB2 Modbus interface PCB for Sky Air & VRV £185.00RTD-10/UK.FB2 Enhanced function PCB for Sky Air: Duty rotation, lead lag control & heating interlock £229.00RTD-20/UK.FB2 Energy Control for Sky Air PoaKliC-Di KNX interface for Sky Air and VRV systems £181.00KRCSo1-4 Remote room mounted temperature sensor £45.00K.RSS Wireless room mounted temperature sensor and receiver £91.00RS-SE Service and Configuration Tool for K.RSS £87.00UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00UK.CGS Condensing Unit Guard size 20-35 £209.00UK.CGM Condensing Unit Guard size 42-71 £290.00

Accessories: Notes:i) *Data for all FFQ-C pairings is provisional

ii) BRC7E530 Trade price will be reduced by £74.00 if ordered at the same time as the fan coil unit in place of the BRC1E52A

iii) All fan coil units standard with auto restart after power failure

iv) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock

v) All fan coils supplied as standard with BYFQ60Q decoration panel. Silver panels available at no extra cost if ordered at same time as fan coil and in place of BYFQ60W

vi) Fan-coil list price will be reduced by £55.00 if FFQ-B9V style deco-panel ordered at same time as fan-coil and in place of BYFQ60W

vii) Minimum ambient operating temperatures:

cooling heatingRXs -10°C -15°C

Indoor Units FFQ25c* FFQ35c* FFQ50c* FFQ60c*Capacity UK Total Cooling kW 2.44 3.32 4.62 5.72

UK Sensible Cooling kW 1.81 2.28 3.40 4.20Nominal Cooling kW 2.50 3.40 4.70 5.80Nominal Heating kW 3.20 4.00 5.50 7.00

Seasonal Efficiency (EN14825) CooliNG

Energy label A A+ A+ A+Pdesign kW 2.50 3.40 4.70 5.80SEER 5.25 5.60 5.70 5.60Annual Energy Consumption kWh 168 210 302 354

Seasonal Efficiency (EN14825) HEATiNG

Energy label A+ A+ A+ A+Pdesign kW 2.31 3.45 3.84 3.96SCoP 4.12 4.09 4.10 4.17Annual Energy Consumption kWh 728 1151 1316 1317

Nominal Efficiency EER / CoP 4.5 / 3.8 3.7 / 3.41 3.21 / 3.5 3.01 / 3.41Energy label A / A A / A A / B B / BAnnual Energy Consumption kWh 280 460 780 945

Air Flow Rate High / low m3/min 9 / 6.5 10 / 6.5 12 / 7.5 14.5 / 9.5Dimensions(with Decoration Panel)

Height mm 260 (306) 260 (306) 260 (306) 260 (306)Width mm 575 (620) 575 (620) 575 (620) 575 (620)Depth mm 575 (620) 575 (620) 575 (620) 575 (620)

Weight (with Decoration Panel) kg 17.5 (20.2) 17.5 (20.2) 17.5 (20.2) 17.5 (20.2)Sound Pressure High / low dBA 31 / 25 34 / 25 39 / 27 43 / 32Sound Power dBA 48 51 56 60

outdoor Units RXs25K* RXs35K* RXs50K* RXs60F*Dimensions Height x Width x Depth mm 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300Weight kg 34 34 47 48Electrical Details Power Supply 1ph

Running Current A tbc tbc tbc tbcStarting Current A 3.3 4.3 6.8 9.4Max Fuse Size A 10 10 20 20

interconnection Wiring Core / Cable size 3+E / 1.5Piping Connections liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2Pipework Maximum length m 20 20 30 30

Maximum Vertical Rise m 15 15 20 20Precharged to m 10 10 10 10Additional Charge g/m 20.0Holding Charge kg 1.0 1.2 1.7 1.5

Sound Pressure High dBA 46 48 48 49Sound Power dBA 46 48 48 49

Trade Fan coil Price £649.00 £712.00 £786.00 £832.00Trade condensing Unit Price £467.00 £541.00 £680.00 £725.00Total system Price £1,116.00 £1,253.00 £1,466.00 £1,557.00

Page 26: Daikin AC Price List 2013

Integrated Solutions24

Split

, Sky

Air

Hea

t Pum

ps

High COP Roundflow Cassette – Seasonal Smart Inverter FCQHG / RZQG

Indoor Units single Phase 3 Phase FcQhG71F FcQhG100F FcQhG125F FcQhG140F FcQhG71F FcQhG100F FcQhG125F FcQhG140F

Capacity UK Total Cooling kW 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90UK Sensible Cooling kW 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) CooliNG

Energy label A++ A++ A++ - A++ A++ A++ -Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -SEER 7.00 7.00 6.61 - 7.00 7.00 6.61 -Annual Energy Consumption kWh 340 475 636 - 340 475 636 -

Seasonal Efficiency (EN14825) HEATiNG

Energy label A+ A++ A++ - A+ A++ A++ -Pdesign kW 7.60 11.30 12.66 - 7.60 11.30 12.66 -SCoP 4.54 4.80 4.63 - 4.54 4.80 4.63 -Annual Energy Consumption kWh 2343 3298 3829 - 2343 3298 3829 -

Nominal Efficiency EER / CoP 4.09 / 4.8 4.42 / 4.99 4 / 4.4 3.35 / 4.12 4.09 / 4.8 4.42 / 4.99 4 / 4.4 3.35 / 4.14Energy label A / A A / A A / A A / A A / A A / A A / A A / AAnnual Energy Consumption kWh 830 1075 1500 2000 830] 1075 1500 2000

Air Flow Rate High / low m3/min 21.2 / 12.2 32.3 / 19 33.5 / 19.9 33.2 / 21.1 21.2 / 12.2 32.3 / 19 33.5 / 19.9 33.2 / 21.1Dimensions (with Decoration Panel)

Height mm 288(348) 288 (348) 288 (348) 288 (348) 288(348) 288 (348) 288 (348) 288 (348)Width mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)Depth mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)

Weight (with Decoration Panel) kg 25 (30.5) 26 (31.4) 26 (31.4) 26 (31.4) 25 (30.5) 26 (31.4) 26 (31.4) 26 (31.4)Sound Pressure High / low dBA 36 / 29 44 / 33 45 / 35 45 / 37 36 / 29 44 / 33 45 / 35 45 / 37Sound Power dBA 53 61 61 61 53 61 61 61

outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 78 102 80 101Electrical Details Power Supply 1ph 3ph

Running Current A 7.68 9.94 13.88 18.50 2.55 3.31 4.61 6.15Starting Current A 4 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 16 20 20 20

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum length m 50 75 75 75 50 75 75 75

Maximum Vertical Rise m 30 30 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30 30Additional Charge g/m Refer to installation Manual Refer to installation ManualHolding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0

Sound Pressure High dBA 48 50 51 52 48 50 51 52Sound Power dBA 48 50 51 52 48 50 51 52

Trade Fan coil Price £812.00 £921.00 £1,007.00 £1,214.00 £812.00 £921.00 £1,007.00 £1,214.00Trade condensing Unit Price £1,168.00 £1,484.00 £1,633.00 £1,864.00 £1,203.00 £1,553.00 £1,709.00 £1,963.00Total system Price £1,980.00 £2,405.00 £2,640.00 £3,078.00 £2,015.00 £2,474.00 £2,716.00 £3,177.00

Features:• TheFCQHGmodelisdesignedfor2014ErPregulationsandhasoneofthehighestCOPvaluesonthemarket• Theunique360°radialairpatternensuresuniformairflowandtemperaturedistribution• Airflowflexibility:awideselectionof23differentairflowpatternsaccessibleviaremotecontroller• OptionalPresenceSensorsdetectsifroomisunoccupiedandallowstemperaturetodrifttoset-backlevels• OptionalSelfCleaningFilterTheBYCQ140DGdecorationpanelcanofferenergysavings,reducedmaintenancetimeandcost• OptionalFreshAirintake(upto20%)possible• SuitableforTwin,TripleandDoubleTwinapplications• Re-useofexistingR22andR407Cpipingpossible• Comms,computerandserverroomcoolingpossiblewithEDPsetting(SeasonalSmart)• Selectableevaporating&condensingtemperatureforgreateroperatingefficiency(SeasonalSmart)• DIIInetcompatibilityasstandard

accessory Ref Description Trade PriceBRC7FA532F Wireless remote controller £149.00BYCQ140DG Roundflow cassette decoration panel with self cleaning filter £303.00 BYCQ140DW Roundflow cassette decoration panel - white with white louvres £156.00 BRYQ140A integral PiR Sensor for Roundflow decoration panel. Enables Energy Saving functions £97.00 KDBHQ55B140 Sealing member for air discharge outlet £88.00KDDQ55B140 1/2 Fresh air intake kit for up to 20% fresh air (not compatible with self cleaning deco-panel) £440.00KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £89.00 RTD-NET/UK.FB2 Modbus interface PCB for Sky Air and VRV £185.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, lead lag control and heating interlock £229.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV Poa KliC-Di KNX interface for Sky Air and VRV systems £181.00 KRCS01-4 Remote room mounted temperature sensor £46.00 K.RSS Wireless room mounted temperature sensor and receiver £91.00 RS-SE Service and Configuration Tool for K.RSS £87.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £45.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £57.00 UK.CGM Condensing Unit Guard size 42-71 £290.00 UK.CGl Condensing Unit Guard size 100-140 including RXYSQ £347.00

Accessories: Notes:i) BRC7FA532F Trade price will be reduced

by £74.00 if ordered at the same time as the fan coil unit in place of the BRC1E52A

ii) All fan coil units standard with auto restart after power failure

iii) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock

iv) All fan coils supplied as standard with BYCQ140D Decoration panel

v) BYCQ140DW / BYCQ140DG Trade prices will be reduced by £139.00 if ordered at the same time as a fan coil in place of standard decoration panel

vi) Minimum ambient operating temperatures:

cooling heatingRZQG -15°C -20°CRZQsG -5°C -15°CRXs -10°C -15°C

Page 27: Daikin AC Price List 2013

Price List 2013 25

Split

, Sky

Air

Hea

t Pum

ps

High COP Roundflow Cassette – Seasonal Classic Inverter FCQHG / RZQSG

Indoor Units single Phase 3 PhaseFcQhG71F FcQhG100F FcQhG125F FcQhG140F FcQhG100F FcQhG125F FcQhG140F

Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) CooliNG

Energy label A++ A++ A - A++ A -Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -SEER 6.50 6.70 5.40 - 6.70 5.40 -Annual Energy Consumption kWh 367 497 778 - 497 778 -

Seasonal Efficiency (EN14825) HEATiNG

Energy label A+ A+ A+ - A+ A+ -Pdesign kW 7.60 8.03 8.03 - 8.03 8.03 -SCoP 4.15 4.30 4.10 - 4.30 4.10 -Annual Energy Consumption kWh 2563 2614 2741 - 2614 2741 -

Nominal Efficiency EER / CoP 3.5 / 4.1 3.7 / 4.3 3.23 / 3.75 3.21 / 3.61 3.7 / 4.3 3.23 / 3.75 3.21 / 3.61Energy label A / A A / A A / A A / A A / A A / A A / AAnnual Energy Consumption kWh 1059 1285 1855 2085 1285 1855 2085

Air Flow Rate High / low m3/min 21.2 / 12.2 32.3 / 19 33.5 / 19.9 45 / 37 32.3 / 19 33.5 / 19.9 45 / 37Dimensions (with Decoration Panel)

Height mm 288(348) 288 (348) 288 (348) 288 (348) 288 (348) 288 (348) 288 (348)Width mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)Depth mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)

Weight (with Decoration Panel) kg 25 (30.5) 26 (31.4) 26 (31.4) 26 (31.4) 26 (31.4) 26 (31.4) 26 (31.4)Sound Pressure High / low dBA 36 / 29 44 / 33 45 / 35 45 / 37 44 / 33 45 / 35 45 / 37Sound Power dBA 53 61 61 61 61 61 61

outdoor Units RZQsG71L3V1 RZQsG100L8V1 RZQsG125L8V1 RZQsG140LV1 RZQsG100L8Y1 RZQsG125L8Y1 RZQsG140LY1Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 67 81 102 82 101Electrical Details Power Supply 1ph 3ph

Running Current A 8.43 11.17 16.13 18.13 3.93 5.67 6.37Starting Current A 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 20 20 20

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum length m 30 50 50 50 50 50 50

Maximum Vertical Rise m 15 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30Additional Charge g/m Refer to installation Manual Refer to installation ManualHolding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0

Sound Pressure High dBA 49 53 54 53 53 54 53Sound Power dBA 49 53 54 53 53 54 53

Trade Fan coil Price £812.00 £921.00 £1,007.00 £1,214.00 £921.00 £1,007.00 £1,214.00Trade condensing Unit Price £864.00 £1,196.00 £1,312.00 £1,461.00 £1,232.00 £1,351.00 £1,505.00Total system Price £1,676.00 £2,117.00 £2,319.00 £2,675.00 £2,153.00 £2,358.00 £2,719.00

Self Cleaning PanelDaikin’s Roundflow Cassette can be equipped with a special filter that cleans itself once a day, ensuring consistent, optimum performance.

Result? Efficiency gains up to 50% compared to standard panels.*

The dust collected during daily auto-cleaning is stored in a dust box that can hold up to 12 months of dust, with an indicator light showing when to clean the dust box. Under normal circumstances, annual or bi-annual cleaning by in-house maintenance personnel using an ordinary vacuum cleaner is all that is needed: no ladders, no need to touch the cassette panel or come in contact with the dust.

* Reference: Coral, Wolverhampton case study.

Page 28: Daikin AC Price List 2013

Integrated Solutions26

Split

, Sky

Air

Hea

t Pum

ps

Compact Roundflow Cassette – Seasonal Smart Inverter FCQG / RZQG

Indoor Units single Phase 3 Phase FcQG71F FcQG100F FcQG125F FcQG140F FcQG71F FcQG100F FcQG125F FcQG140F

Capacity UK Total Cooling kW 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90UK Sensible Cooling kW 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) CooliNG

Energy label A++ A++ A+ - A++ A++ A+ -Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -SEER 6.80 6.80 6.00 - 6.80 6.80 6.00 -Annual Energy Consumption kWh 350 489 700 - 350 489 700 -

Seasonal Efficiency (EN14825) HEATiNG

Energy label A+ A++ A+ - A+ A++ A+ -Pdesign kW 6.33 11.30 12.66 - 6.33 11.30 12.66 -SCoP 4.20 4.61 4.10 - 4.20 4.61 4.10 -Annual Energy Consumption kWh 2111 3433 4324 - 2111 3433 4324 -

Nominal Efficiency EER / CoP 3.39 / 3.97 3.87 / 4.15 3.73 / 3.63 3.21 / 3.61 3.39 / 3.97 3.87 / 4.15 3.73 / 3.63 3.21 / 3.61Energy label A / A A / A A / A A / A A / A A / A A / A A / AAnnual Energy Consumption kWh 1005 1225 1610 2085 1005 1225 1610 2085

Air Flow Rate High / low m3/min 15 / 9.1 22.8 / 12.4 26 / 12.4 26 / 12.4 15 / 9.1 22.8 / 12.4 26 / 12.4 26 / 12.4Dimensions (with Decoration Panel)

Height mm 204 (264) 246 (306) 246 (306) 246 (306) 204 (264) 246 (306) 246 (306) 246 (306)Width mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)Depth mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)

Weight (with Decoration Panel) kg 21 (26.4) 24 (29.4) 24 (29.4) 24 (29.4) 21 (26.4) 24 (29.4) 24 (29.4) 24 (29.4)Sound Pressure High / low dBA 33 / 28 37 / 29 41 / 29 41 / 29 33 / 28 37 / 29 41 / 29 41 / 29Sound Power dBA 51 54 58 58 51 54 58 58

outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 78 102 80 101Electrical Details Power Supply 1ph 3ph

Running Current A 9.30 11.33 14.89 19.29 3.09 3.77 4.95 6.41Starting Current A 4 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 16 20 20 20

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum length m 50 75 75 75 50 75 75 75

Maximum Vertical Rise m 30 30 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30 30Additional Charge g/m Refer to installation Manual Refer to installation ManualHolding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0

Sound Pressure High dBA 48 50 51 52 48 50 51 52Sound Power dBA 48 50 51 52 48 50 51 52

Trade Fan coil Price £812.00 £921.00 £1,007.00 £1,214.00 £812.00 £921.00 £1,007.00 £1,214.00Trade condensing Unit Price £1,168.00 £1,484.00 £1,633.00 £1,864.00 £1,203.00 £1,553.00 £1,709.00 £1,963.00Total system Price £1,980.00 £2,405.00 £2,640.00 £3,078.00 £2,015.00 £2,474.00 £2,716.00 £3,177.00

Features:• FCQGisacompactcassettedesignedtosuitinstallationinnarrowerceilingvoids• Theunique360°radialairpatternensuresuniformairflowandtemperaturedistribution• Airflowflexibility:awideselectionof23differentairflowpatternsaccessibleviaremotecontroller• OptionalPresenceSensorsdetectsifroomisunoccupiedandallowstemperaturetodrifttoset-backlevels• OptionalSelfCleaningFilter:TheBYCQ140DGdecorationpanelcanofferenergysavings,reducedmaintenancetimeandcost• OptionalFreshAirintake(upto20%)possible• Re-useofexistingR22andR407Cpipingpossible• Comms,computerandserverroomcoolingpossiblewithEDPsetting(SeasonalSmart)• Selectableevaporating&condensingtemperatureforgreateroperatingefficiency(SeasonalSmart)• DIIInetcompatibilityasstandard

Accessories: Notes:i) BRC7FA532F Trade price will be reduced

by £74.00 if ordered at the same time as the fan coil unit in place of the BRC1E52A

ii) All fan coil units standard with auto restart after power failure

iii) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock

iv) All fan coils supplied as standard with BYCQ140D Decoration panel

v) BYCQ140DW / BYCQ140DG Trade prices will be reduced by £139.00 if ordered at the same time as a fan coil in place of standard decoration panel

vi) Minimum ambient operating temperatures:

cooling heatingRZQG -15°C -20°CRZQsG -5°C -15°CRXs -10°C -15°C

accessory Ref Description Trade PriceBRC7FA532F Wireless remote controller £149.00 BYCQ140DG Roundflow cassette decoration panel with self cleaning filter £303.00 BYCQ140DW Roundflow cassette decoration panel - white with white louvres £156.00 BRYQ140A integral PiR Sensor for Roundflow decoration panel. Enables Energy Saving functions £97.00 KDBHQ55B140 Sealing member for air discharge outlet £88.00 KDDQ55B140 1/2 Fresh air intake kit for up to 20% fresh air (not compatible with self cleaning deco-panel) £440.00 KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £89.00 RTD-NET/UK.FB2 Modbus interface PCB for Sky Air and VRV £185.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, lead lag control and heating interlock £229.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV Poa KliC-Di KNX interface for Sky Air and VRV systems £181.00 KRCS01-4 Remote room mounted temperature sensor £46.00 K.RSS Wireless room mounted temperature sensor and receiver £91.00 RS-SE Service and Configuration Tool for K.RSS £87.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £45.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £57.00 UK.CGM Condensing Unit Guard size 42-71 £290.00 UK.CGl Condensing Unit Guard size 100-140 including RXYSQ £347.00

Page 29: Daikin AC Price List 2013

Price List 2013 27

Split

, Sky

Air

Hea

t Pum

ps

Compact Roundflow Cassette – Seasonal Classic Inverter FCQG / RZQSG

Indoor Units single Phase 3 PhaseFcQG71F FcQG100F FcQG125F FcQG140F FcQG100F FcQG125F FcQG140F

Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) CooliNG

Energy label A+ A++ A - A++ A -Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -SEER 6.10 6.50 5.30 - 6.50 5.30 -Annual Energy Consumption kWh 391 512 793 - 512 793 -

Seasonal Efficiency (EN14825) HEATiNG

Energy label A+ A+ B - A+ B -Pdesign kW 6.33 7.60 8.03 - 7.60 8.03 -SCoP 4.10 4.10 3.41 - 4.10 3.41 -Annual Energy Consumption kWh 2162 2799 2803 - 2799 2803 -

Nominal Efficiency EER / CoP 3.21 / 3.61 3.3 / 3.54 3.21 / 3.41 3.01 / 3.41 3.21 / 3.54 3.21 / 3.41 3.01 / 3.41Energy label A / A A / A A / B B / B A / A A / B B / BAnnual Energy Consumption kWh 971 1440 1870 1725 1440 1870 1725

Air Flow Rate High / low m3/min 15 / 9.1 22.8 / 12.4 26 / 12.4 26 / 12.4 22.8 / 12.4 26 / 12.4 26 / 12.4Dimensions (with Decoration Panel)

Height mm 204 (264) 246 (306) 246 (306) 246 (306) 246 (306) 246 (306) 246 (306)Width mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)Depth mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)

Weight (with Decoration Panel) kg 21 (26.4) 24 (29.4) 24 (29.4) 24 (29.4) 24 (29.4) 24 (29.4) 24 (29.4)Sound Pressure High / low dBA 33 / 28 37 / 29 41 / 29 41 / 29 37 / 29 41 / 29 41 / 29Sound Power dBA 51 54 58 58 54 58 58

outdoor Units RZQsG71L3V1 RZQsG100L8V1 RZQsG125L8V1 RZQsG140LV1 RZQsG100L8Y1 RZQsG125L8Y1 RZQsG140LY1Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 67 81 102 82 101Electrical Details Power Supply 1ph 3ph

Running Current A 9.22 12.52 16.26 19.35 4.40 5.72 6.80Starting Current A 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 20 20 20

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum length m 30 50 50 50 50 50 50

Maximum Vertical Rise m 15 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30Additional Charge g/m Refer to installation Manual Refer to installation ManualHolding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0

Sound Pressure High dBA 49 53 54 53 53 54 53Sound Power dBA 49 53 54 53 53 54 53

Trade Fan coil Price £812.00 £921.00 £1,007.00 £1,214.00 £921.00 £1,007.00 £1,214.00Trade condensing Unit Price £864.00 £1,196.00 £1,312.00 £1,461.00 £1,232.00 £1,351.00 £1,505.00Total system Price £1,676.00 £2,117.00 £2,319.00 £2,675.00 £2,153.00 £2,358.00 £2,719.00

Page 30: Daikin AC Price List 2013

Integrated Solutions28

Split

, Sky

Air

Hea

t Pum

ps

Compact Roundflow Cassette – Inverter FCQG / RXS

Indoor Units FcQG35F FcQG50F FcQG60FCapacity UK Total Cooling kW 3.32 4.89 5.57

UK Sensible Cooling kW 2.29 3.26 3.67Nominal Cooling kW 3.40 5.00 5.70Nominal Heating kW 4.20 6.00 7.00

Seasonal Efficiency (EN14825) CooliNG

Energy label A A+ A+Pdesign kW 3.40 5.00 5.70SEER 5.34 5.89 5.74Annual Energy Consumption kWh 230 297 347

Seasonal Efficiency (EN14825) HEATiNG

Energy label A++ A+ APdesign kW 3.32 4.36 4.71SCoP 4.74 4.24 3.87Annual Energy Consumption kWh 981 1442 1704

Nominal Efficiency EER / CoP 3.58 / 3.41 3.55 / 3.7 3.48 / 3.52Energy label A / B A / A A / BAnnual Energy Consumption kWh 475 705 820

Air Flow Rate High / low m3/min 12.5 / 8.7 12.6 / 8.7 13.6 / 8.7Dimensions (with Decoration Panel)

Height mm 204 (254) 204 (254) 204 (254)Width mm 840 (950) 840 (950) 840 (950)Depth mm 840 (950) 840 (950) 840 (950)

Weight (with Decoration Panel) kg 18 (23.4) 19 (24.4) 19 (24.4)Sound Pressure High / low dBA 31 / 27 31 / 27 33 / 28Sound Power dBA 49 49 51

outdoor Units RXs35K RXs50K RXs60FDimensions Height x Width x Depth mm 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300Weight kg 34 47 48Electrical Details Power Supply 1ph

Running Current A 4.18* 6.48* 8.62*Starting Current A 4.30 6.80 9.40Max Fuse Size A 10 20 20

interconnection Wiring Core / Cable size 3+E / 1.5Piping Connections liquid / Gas inches 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2Pipework Maximum length m 20 30 30

Maximum Vertical Rise m 15 20 20Precharged to m 10 10 10Additional Charge g/m 20.0 20.0 20.0Holding Charge kg 1.2 1.7 1.5

Sound Pressure High dBA 48 48 49Sound Power dBA 48 48 49

Trade Fan coil Price £703.00 £720.00 £766.00Trade condensing Unit Price £541.00 £680.00 £725.00Total system Price £1,244.00 £1,400.00 £1,491.00

Features:• FCQGisacompactcassettedesignedtosuitinstallationinnarrowerceilingvoids• Theunique360°radialairpatternensuresuniformairflowandtemperaturedistribution• Airflowflexibility:awideselectionof23differentairflowpatternsaccessibleviaremotecontroller• OptionalPresenceSensorsdetectsifroomisunoccupiedandallowstemperaturetodrifttoset-backlevels• OptionalSelfCleaningFilter:TheBYCQ140DGdecorationpanelcanofferenergysavings,reducedmaintenancetimeandcost• SuitableforTwin,TripleandDoubleTwinapplications• Re-useofexistingR22andR407Cpipingpossible• DIIInetcompatibilityasstandard

Accessories: Notes:i) BRC7FA532F Trade price will be reduced

by £74.00 if ordered at the same time as the fan coil unit in place of the BRC1E52A

ii) All fan coil units standard with auto restart after power failure

iii) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock

iv) All fan coils supplied as standard with BYCQ140D Decoration panel

v) BYCQ140DW / BYCQ140DG Trade prices will be reduced by £139.00 if ordered at the same time as a fan coil in place of standard decoration panel

vi) Data marked with * is preliminary

vii) Minimum ambient operating temperatures:

cooling heatingRZQG -15°C -20°CRZQsG -5°C -15°CRXs -10°C -15°C

accessory Ref Description Trade PriceBRC7FA532F Wireless remote controller £149.00 BYCQ140DG Roundflow cassette decoration panel with self cleaning filter £303.00 BYCQ140DW Roundflow cassette decoration panel - white with white louvres £156.00 BRYQ140A integral PiR Sensor for Roundflow decoration panel. Enables Energy Saving functions £97.00 KDBHQ55B140 Sealing member for air discharge outlet £88.00KDDQ55B140 1/2 Fresh air intake kit for up to 20% fresh air (not compatible with self cleaning deco-panel) £440.00 KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £89.00 RTD-NET/UK.FB2 Modbus interface PCB for Sky Air and VRV £185.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, lead lag control and heating interlock £229.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV Poa KliC-Di KNX interface for Sky Air and VRV systems £181.00 KRCS01-4 Remote room mounted temperature sensor £46.00 K.RSS Wireless room mounted temperature sensor and receiver £91.00 RS-SE Service and Configuration Tool for K.RSS £87.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £45.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £57.00 UK.CGM Condensing Unit Guard size 42-71 £290.00 UK.CGl Condensing Unit Guard size 100-140 including RXYSQ £347.00

Page 31: Daikin AC Price List 2013

Price List 2013 29

Split

, Sky

Air

Hea

t Pum

ps

Under Ceiling Cassette – Seasonal Smart Inverter FUQ-C / RZQG

Indoor Units single Phase 3 Phase FUQ71c FUQ100c FUQ125c FUQ71c FUQ100c FUQ125c

Capacity UK Total Cooling kW 7.76 10.80 13.60 7.76 10.80 13.60UK Sensible Cooling kW 5.32 7.44 9.30 5.32 7.44 9.30Nominal Cooling kW 6.80 9.50 12.00 6.80 9.50 12.00Nominal Heating kW 7.50 10.80 13.50 7.50 10.80 13.50

Seasonal Efficiency (EN14825) CooliNG

Energy label A++ A++ A+ A++ A++ A+ Pdesign kW 6.80 9.50 12.00 6.80 9.50 12.00SEER 6.50 6.11 5.61 6.50 6.11 5.61Annual Energy Consumption kWh 367 545 749 367 545 749

Seasonal Efficiency (EN14825) HEATiNG

Energy label A+ A+ A+ A+ A+ A+Pdesign kW 7.60 11.30 14.13 7.60 11.30 14.13SCoP 4.20 4.50 4.44 4.20 4.50 4.44Annual Energy Consumption kWh 2533 3517 4456 2533 3517 4456

Nominal Efficiency EER / CoP 4.07 / 4.47 4.08 / 4.04 3.4 / 4.04 4.07 / 4.47 4.08 / 4.04 3.4 / 4.04Energy label A / A A / A A / A A / A A / A A / AAnnual Energy Consumption kWh 840 1230 1770 840 1230 1770

Air Flow Rate High / low m3/min 23 / 16 31 / 20 32.5 / 20.5 23 / 16 31 / 20 32.5 / 20.5Dimensions Height mm 198 198 198 198 198 198

Width mm 950 950 950 950 950 950Depth mm 950 950 950 950 950 950

Weight kg 25 26 26 25 26 26Sound Pressure High / low dBA 41 / 35 46 / 39 47 / 40 41 / 35 46 / 39 47 / 40Sound Power dBA 59 64 65 59 64 65

outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 78 102 80 101Electrical Details Power Supply 1ph 3ph

Running Current A 7.72 10.78 15.91 2.57 3.58 5.29Starting Current A 4 4 4 4 4 4Max Fuse Size A 20 32 32 16 20 20

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum length m 50 75 75 50 75 75

Maximum Vertical Rise m 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30Additional Charge g/m Refer to installation Manual Refer to installation ManualHolding Charge kg 2.9 4.0 4.0 2.9 4.0 4.0

Sound Pressure High dBA 48 50 51 48 50 51Sound Power dBA 48 50 51 48 50 51

Trade Fan coil Price £897.00 £984.00 £1,087.00 £897.00 £984.00 £1,087.00Trade condensing Unit Price £1,168.00 £1,484.00 £1,633.00 £1,203.00 £1,553.00 £1,709.00Total system Price £2,065.00 £2,468.00 £2,720.00 £2,100.00 £2,537.00 £2,796.00

Features:• The4-wayblowceilingsuspendedcassettesaretheidealsolutionforrooms,shopsorofficeswithoutfalseceilings• SeasonallyEfficientInverterTechnologygivesupto25%betterefficiencythaninvertertechnology• Airflowflexibility:aircanbedischargedinanyof4directions.Possibilitytoshutoff1or2flapsenablingtheunittobeinstalledinacornerorsmallroom• 3stepfan-speed• SuitableforTwin,TripleandDoubleTwinapplications• Re-useofexistingR22andR407Cpipingpossible• Comms,computerandserverroomcoolingpossiblewithEDPsetting• Selectableevaporating&condensingtemperatureforgreateroperatingefficiency

accessory Ref Description Trade PriceBRC7C58 Wireless remote controller £149.00EKRoRo5 Remote on/off control interface kit £28.00 KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £89.00 RTD-NET/UK.FB2 Modbus interface PCB for Sky Air and VRV £185.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, lead lag control and heating interlock £229.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV Poa KliC-Di KNX interface for Sky Air and VRV systems £181.00 KRCS01-1 Remote room mounted temperature sensor £45.00 K.RSS Wireless room mounted temperature sensor and receiver £91.00 RS-SE Service and Configuration Tool for K.RSS £87.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £45.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £57.00 UK.CGM Condensing Unit Guard size 42-71 £290.00 UK.CGl Condensing Unit Guard size 100-140 including RXYSQ £347.00

Accessories: Notes:i) BRC7C58 Trade price will be reduced by

£74.00 if ordered at the same time as the fan coil unit in place of the BRC1E52A

ii) All fan coil units standard with auto restart after power failure

iii) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock

iv) Minimum ambient operating temperatures:

cooling heatingRZQG -15°C -20°C

Page 32: Daikin AC Price List 2013

Integrated Solutions30

Split

, Sky

Air

Hea

t Pum

ps

Built in DC Ducted – Seasonal Smart Inverter FBQ / RZQG

Indoor Units single Phase 3 Phase FBQ71c8 FBQ100c8 FBQ125c8 FBQ140c8 FBQ71c8 FBQ100c8 FBQ125c8 FBQ140c8

Capacity UK Total Cooling kW 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90UK Sensible Cooling kW 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) CooliNG

Energy label A++ A+ A+ - A++ A+ A+ -Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -SEER 6.11 5.80 5.81 - 6.11 5.80 5.81 -Annual Energy Consumption kWh 390 574 723 - 390 574 723 -

Seasonal Efficiency (EN14825) HEATiNG

Energy label A+ A++ A+ - A+ A++ A+ -Pdesign kW 6.00 11.30 12.71 - 6.00 11.30 12.71 -SCoP 4.01 4.61 4.21 - 4.01 4.61 4.21 -Annual Energy Consumption kWh 2096 3433 4226 - 2096 3433 4226 -

Nominal Efficiency EER / CoP 3.5 / 3.65 3.89 / 4.21 3.81 / 3.83 3.33 / 3.61 3.5 / 3.65 3.89 / 4.21 3.81 / 3.83 3.33 / 3.61Energy label A / A A / A A / A A / A A / A A / A A / A A / AAnnual Energy Consumption kWh 970 1220 1575 2010 970 1220 1575 2010

Air Flow Rate High / low m3/min 18 / 15 32 / 23 39 / 28 39 / 28 18 / 15 32 / 23 39 / 28 39 / 28Dimensions Height mm 300 300 300 300 300 300 300 300

Width mm 1000 1400 1400 1400 1000 1400 1400 1400Depth mm 700 700 700 700 700 700 700 700

Weight kg 38 45 45 45 38 45 45 45Sound Pressure High / low dBA 37 / 29 38 / 32 40 / 33 40 / 33 37 / 29 38 / 32 40 / 33 40 / 33Sound Power dBA 57 61 66 66 57 61 66 66

outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 78 102 80 101Electrical Details Power Supply 1ph 3ph

Running Current A 8.97 11.29 14.57 18.59 2.98 3.75 4.84 6.18Starting Current A 4 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 16 20 20 20

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum length m 50 75 75 75 50 75 75 75

Maximum Vertical Rise m 30 30 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30 30Additional Charge g/m Refer to installation Manual Refer to installation ManualHolding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0

Sound Pressure High dBA 48 50 51 52 48 50 51 52Sound Power dBA 48 50 51 52 48 50 51 52

Trade Fan coil Price £899.00 £941.00 £1,114.00 £1,292.00 £899.00 £941.00 £1,114.00 £1,292.00Trade condensing Unit Price £1,168.00 £1,484.00 £1,633.00 £1,864.00 £1,203.00 £1,553.00 £1,709.00 £1,963.00Total system Price £2,067.00 £2,425.00 £2,747.00 £3,156.00 £2,102.00 £2,494.00 £2,823.00 £3,255.00

Features:• The new inverter fan ducted units, provides both drastic energy savings and simplifies installation• AutomaticallyadjustsairvolumeagainstESPatcommissioning• Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology• Comms, computer and server room cooling possible with EDP setting• Selectableevaporating&condensingtemperatureforgreateroperatingefficiency

accessory Ref Description applicable Units Trade PriceBRC4C65 Wireless remote controller £149.00 EKRoRo3 Remote on/off control interface kit £28.00 KRP4A53 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £65.00 RTD-NET/UK.FB2 Modbus interface PCB for Sky Air and VRV £185.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, lead lag control and heating interlock £229.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV Poa KliC-Di KNX interface for Sky Air and VRV systems £181.00 KRCS01-4 Remote room mounted temperature sensor £46.00 K.RSS Wireless room mounted temperature sensor and receiver £91.00 RS-SE Service and Configuration Tool for K.RSS £87.00 BYBS71D Return air suction grille FBQ71 £155.00 BYBS125D Return air suction grille FBQ100~140 £194.00 EKBYBSD Mounting Kit for Decoration Panel (when installed directly onto the unit body) £27.00 UK.RAC3 Return Air Chamber, 2no 200mm dia FBQ71 £84.00 UK.RAC3A Return Air Chamber, 3no 200mm dia FBQ71 £91.00 UK.RAC4 Return Air Chamber, 4no 200mm dia FBQ100~140 £113.00 UK.SAF3 Supply Air Flange 2x 200dia FBQ71 £77.00 UK.SAF3A Supply Air Flange 3x 200dia FBQ71 £82.00 UK.SAF4 Supply Air Flange 4x 200dia FBQ100~140 £101.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £45.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £57.00 UK.CGM Condensing Unit Guard size 42-71 £290.00 UK.CGl Condensing Unit Guard size 100-140 including RXYSQ £347.00

Accessories: Notes:i) BRC4C65 Trade price will be reduced by

£74.00 if ordered at the same time as the fan coil unit in place of the BRC1E52A

ii) All fan coil units standard with auto restart after power failure

iii) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock

iv) All fan coils supplied as standard with air filter

v) Minimum ambient operating temperatures:

cooling heatingRZQG -15°C -20°CRZQsG -5°C -15°C

• Fanspeed:2fanspeedscanbeselected,highorlow• SuitableforTwin,TripleandDoubleTwinapplications• Re-useofexistingR22andR407Cpipingpossible• DIIInetcompatibilityasstandard

Page 33: Daikin AC Price List 2013

Price List 2013 31

Split

, Sky

Air

Hea

t Pum

ps

Built in DC Ducted – Seasonal Classic Inverter FBQ / RZQSG

Indoor Units single Phase 3 PhaseFBQ71c8 FBQ100c8 FBQ125c8 FBQ140c8 FBQ100c8 FBQ125c8 FBQ140c8

Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25Nominal Cooling kW 6.80 9.50 12.00 13.40 9.50 12.00 13.40Nominal Heating kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50

Seasonal Efficiency (EN14825) CooliNG

Energy label A+ A A - A A -Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -SEER 5.81 5.50 5.20 - 5.50 5.20 -Annual Energy Consumption kWh 410 605 808 - 6 5 -

Seasonal Efficiency (EN14825) HEATiNG

Energy label A A+ A - 605.00 808.00 -Pdesign kW 6.00 7.60 7.60 - 4.01 3.90 -SCoP 3.88 4.01 3.90 - A A -Annual Energy Consumption kWh 2156 2553 2727 - A+ A -

Nominal Efficiency EER / CoP 3.28 / 3.61 3.31 / 3.65 3.21 / 3.51 3.02 / 3.41 3.31 / 3.65 3.21 / 3.51 3.02 / 3.41Energy label A / A A / A A / B B / B A / A A / B B / BAnnual Energy Consumption kWh 1037 1435 1870 2220 1435 1870 2220

Air Flow Rate High / low m3/min 18 / 15 32 / 23 39 / 28 39 / 28 32 / 23 39 / 28 39 / 28Dimensions Height mm 300 300 300 300 300 300 300

Width mm 1000 1400 1400 1400 1400 1400 1400Depth mm 700 700 700 700 700 700 700

Weight kg 38 45 45 45 45 45 45Sound Pressure High / low dBA 37 / 29 38 / 32 40 / 33 40 / 33 38 / 32 40 / 33 40 / 33Sound Power dBA 57 61 66 66 61 66 66

outdoor Units RZQsG71L3V1 RZQsG100L8V1 RZQsG125L8V1 RZQsG140LV1 RZQsG100L8Y1 RZQsG125L8Y1 RZQsG140LY1Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320Weight kg 67 81 102 82 101Electrical Details Power Supply 1ph 3ph

Running Current A 9.00 12.48 16.26 19.30 4.39 5.72 6.79Starting Current A 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 20 20 20

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum length m 30 50 50 50 50 50 50

Maximum Vertical Rise m 15 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30 30Additional Charge g/m Refer to installation Manual Refer to installation ManualHolding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0

Sound Pressure High dBA 49 53 54 53 53 54 53Sound Power dBA 49 53 54 53 53 54 53

Trade Fan coil Price £899.00 £941.00 £1,114.00 £1,292.00 £941.00 £1,114.00 £1,292.00Trade condensing Unit Price £864.00 £1,196.00 £1,312.00 £1,461.00 £1,232.00 £1,351.00 £1,505.00Total system Price £1,763.00 £2,137.00 £2,426.00 £2,753.00 £2,173.00 £2,465.00 £2,797.00

Page 34: Daikin AC Price List 2013

Integrated Solutions32

Split

, Sky

Air

Hea

t Pum

ps

Built in DC Ducted & Slim Ducted – Inverter FBQ&FDXS-F/RXS

Indoor Units Dc Ducted slim DuctedFBQ35c8 FBQ50c8 FBQ60c8 FDXs25F FDXs35F FDXs50F FDXs60F

Capacity UK Total Cooling kW 3.32 4.89 5.60 2.35 3.32 4.81 5.86UK Sensible Cooling kW 2.93 3.60 4.50 1.81 2.26 3.08 3.97Nominal Cooling kW 3.40 5.00 5.70 2.40 3.40 5.00 6.00Nominal Heating kW 4.00 6.00 7.00 3.20 4.00 5.80 7.00

Seasonal Efficiency (EN14825) CooliNG

Energy label C B A B B A APdesign kW 3.40 5.00 5.70 2.40 3.40 5.00 6.00SEER 4.33 4.96 5.17 5.08 4.82 5.12 5.50Annual Energy Consumption kWh 283 346 406 165 247 342 382

Seasonal Efficiency (EN14825) HEATiNG

Energy label A A A A+ A A APdesign kW 3.50 4.90 4.80 2.60 2.90 3.50 4.00SCoP 3.56 3.53 3.43 4.19 3.81 3.41 3.51Annual Energy Consumption kWh 1141 1782 1960 869 1066 1438 1596

Nominal Efficiency EER / CoP 3.21 / 3.51 3.03 / 3.42 3.26 / 3.41 3.72 / 3.9 3.21 / 3.39 3.03 / 3.1 2.91 / 3.21Energy label A / B B / B A / B A / A A / B B / D C / CAnnual Energy Consumption kWh 530 825 875 323 530 825 1030

Air Flow Rate High / low m3/min 16 / 11 16 / 11 18 / 15 8.7 / 7.3 8.7 / 7.3 12 / 10 16 / 13.5Dimensions Height mm 300 300 300 200 200 200 200

Width mm 700 700 1000 750 750 950 1150Depth mm 700 700 700 620 620 620 620

Weight kg 27 28 38 21 21 27 30Sound Pressure High / low dBA 32 / 27 37 / 29 37 / 30 35 / 27 35 / 27 37 / 29 38 / 30Sound Power dBA 50 55 55 53 53 55 56

outdoor Units RXs35K RXs50K RXs60F RXs25K RXs35K RXs50K RXs60FDimensions Height x Width x Depth mm 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300Weight kg 34 47 48 34 34 47 48Electrical Details Power Supply 1ph - see notes 1ph 1ph

Running Current A 5.03* 8.38* 10.1* 3.90 4.90 7.10 9.20Starting Current A 4.3 6.8 9.4 3.3 4.3 6.8 9.4Max Fuse Size A 10 20 20 10 10 20 20

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections liquid / Gas inches 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2Pipework Maximum length m 20 30 30 20 20 30 30

Maximum Vertical Rise m 15 20 20 15 15 20 20Precharged to m 10 10 10 10 10 10 10Additional Charge g/m 20.0 20.0Holding Charge kg 1.2 1.7 1.5 1.0 1.2 1.7 1.5

Sound Pressure High dBA 48 48 49 46 48 48 49Sound Power dBA 48 48 49 46 48 48 49

Trade Fan coil Price £536.00 £563.00 £626.00 £386.00 £432.00 £467.00 £513.00Trade condensing Unit Price £541.00 £680.00 £725.00 £467.00 £541.00 £680.00 £725.00Total system Price £1,077.00 £1,243.00 £1,351.00 £853.00 £973.00 £1,147.00 £1,238.00

accessory Ref Description applicable Units Trade PriceBRC4C65 Wireless remote controller FBQ / FDXs £149.00BRC2C51 Simplified remote control FDXsEKRoRo3 Remote on/off control interface kit FBQ £28.00KRP4A53 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting FBQ £65.00RTD-NET/UK.FP Modbus interface PCB for Sky Air & VRV FBQ / FDXs £185.00RTD-10/UK.FP Enhanced function PCB for Sky Air: Duty rotation, lead lag control & heating interlock FBQ / FDXs £229.00RTD-20/UK.FP Energy Control for Sky Air FBQ / FDXs PoaKliC-Di KNX interface for Sky Air and VRV systems FBQ / FDXs £181.00KRCS01-4 Remote room mounted temperature sensor FBQ / FDXs £46.00K.RSS Wireless room mounted temperature sensor and receiver FBQ £91.00RS-SE Service and Configuration Tool for K.RSS FBQ £87.00BYBS45D Return air suction grille FBQ35~50 £118.00BYBS71D Return air suction grille FBQ60 £155.00UK.RAC2 Return Air Chamber, 2 x 200mm dia FBQ35~50 £77.00UK.RAC3 Return Air Chamber, 2 x 200mm dia FBQ60 £84.00UK.RAC3A Return Air Chamber, 3 x 200mm dia FBQ60 £91.00UK.RAC5 Return Air Chamber, 2 x 150mm dia FDXs25~35 PoaUK.RAC6 Return Air Chamber, 3 x 150mm dia FDXs50 PoaUK.RAC7 Return Air Chamber, 4 x 150mm dia FDXs60~71 PoaUK.SAF2 Supply Air Flange 2 x 200mm dia FBQ35~50 £70.00UK.SAF3 Supply Air Flange 2 x 200mm dia FBQ60 £77.00UK.SAF3A Supply Air Flange 3 x 200mm dia FBQ60 £82.00UK.SAF5 Supply Air Flange 2 x 150mm dia FDXs25~35 £65.00UK.SAF6 Supply Air Flange 3 x 150mm dia FDXs50 £71.00UK.SAF7 Supply Air Flange 4 x 150mm dia FDXs60~71 £83.00UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00UK.CGS Condensing Unit Guard size 20-35 £209.00UK.CGM Condensing Unit Guard size 42-71 £290.00

Accessories: Notes:i) Data marked * is provisional

ii) BRC4C65 Trade price will be reduced by £74.00 if ordered at the same time as the fan coil unit in place of the BRC1E52A

iii) All fan coil units standard with auto restart after power failure

iv) FBQ and FDXS fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock

v) All fan coils supplied as standard with air filter

vi) Minimum ambient operating temperatures:

vii) FBQ35C Fan Coil unit requires a separate 1ph 5 amp power supply

cooling heatingRZQG -15°C -20°CRZQsG -5°C -15°CRXs -10°C -15°C

Features:• Fanspeed:5fanspeedscanbeselected,hightosuperlow • Connectiontomultioutdoorpossible • Re-useofexistingR22andR407Cpipingpossible

Page 35: Daikin AC Price List 2013

Price List 2013 33

Split

, Sky

Air

Hea

t Pum

ps

High Static Ducted – Seasonal Smart, Classic & Super Inverter FDQ

Indoor Units single Phase 3 Phase single Phase 3 Phase super Inverter (3 phase)FDQ125c FDQ125c FDQ125c FDQ125c FDQ200B FDQ250B

Capacity UK Total Cooling kW 13.60 13.60 13.60 13.60 19.40 23.50UK Sensible Cooling kW 9.30 9.30 9.30 9.30 16.30 20.70Nominal Cooling kW 12.00 12.00 12.00 12.00 20.00 25.00Nominal Heating kW 13.50 13.50 13.50 13.50 23.00 27.00

Seasonal Efficiency (EN14825) CooliNG

Energy label A A A A - -Pdesign kW 12.00 12.00 12.00 12.00 - -SEER 5.81 5.81 5.20 5.20 - -Annual Energy Consumption kWh 723 723 806 806 - -

Seasonal Efficiency (EN14825) HEATiNG

Energy label A+ A+ A A - -Pdesign kW 12.71 12.71 7.60 7.60 - -SCoP 4.21 4.21 3.90 3.90 - -Annual Energy Consumption kWh 4226 4226 2727 2727 - -

Nominal Efficiency EER / CoP 3.75 / 3.83 3.75 / 3.83 3.21 / 3.51 3.21 / 3.51 3.21 / 3.41 2.81 / 3.21Energy label A / A A / A A / B A / B A / B C / CAnnual Energy Consumption kWh 1600 1600 1870 1870 3115 4290

Air Flow Rate High / low m3/min 39 / 28 39 / 28 39 / 28 39 / 28 69 / 69 89 / 89Dimensions Height mm 300 300 300 300 450 450

Width mm 1400 1400 1400 1400 1400 1400Depth mm 700 700 700 700 900 900

Weight kg 45 45 45 45 93 93Sound Pressure High / low dBA 40 / 33 40 / 33 40 / 33 40 / 33 45 / 45 47 / 47Sound Power dBA 66 66 66 66 81 82

outdoor Units RZQG125L8V1 RZQG125L8Y1 RZQsG125L8V1 RZQsG125L8Y1 RZQ200c RZQ250cDimensions Height x Width x Depth mm 1430 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 990 x 940 x 320 1680 x 930 x 765 1680 x 930 x 765Weight kg 102 101 81 82 183 184Electrical Details Power Supply 1ph - see notes 3ph - see notes 1ph - see notes 3ph - see notes 3ph - see notes

Running Current A 14.80 4.89 17.30 5.72 4.61 6.35Starting Current A 4 4 4 4 4 4Max Fuse Size A 32 20 32 20 25 25

interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5Piping Connections liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 7/8 1/2 / 7/8Pipework Maximum length m 75 75 50 50 100 100

Maximum Vertical Rise m 30 30 30 30 30 30Precharged to m 30 30 30 30 30 30Additional Charge g/m Refer to installation Manual Refer to installation ManualHolding Charge kg 4.0 4.0 2.9 2.9 8.3 9.3

Sound Pressure High dBA 51 51 54 54 57 57Sound Power dBA 51 51 54 54 57 57

Trade Fan coil Price £1,219.00 £1,219.00 £1,219.00 £1,219.00 £1,530.00 £1,874.00Trade condensing Unit Price £1,633.00 £1,709.00 £1,312.00 £1,351.00 £2,862.00 £2,998.00Total system Price £2,852.00 £2,928.00 £2,531.00 £2,570.00 £4,392.00 £4,872.00

Features:• Highstaticunitsforlongerductedruns• Upto200PaExternalStaticPressure• Autobalancingairflow/ESPoncommissioning• Comms,computerandserverroomcoolingpossible(SeasonalSmartonly)• Superinvertertechnology:reducespowerconsumptionbyupto70%comparedtononinverterunits• Selectableevaporating&condensingtemperatureforgreateroperatingefficiency(SeasonalSmartonly)

accessory Ref Description Trade PriceEKRoRo Remote on/off control interface kit £15.00 KRP4A53 Unit/Group adaptor PCB for remote on/off, status indication and temperature setting £65.00 RTD-NET/UK.FB2 Modbus interface PCB for Sky Air and VRV £185.00 RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, lead lag control and heating interlock £229.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV Poa KliC-Di KNX interface for Sky Air and VRV systems £181.00 DTA112B51 Adaptor PCB for interface to Daikin centralised control systems (FDQ250B and FDQ200B only) £87.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £45.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £57.00 UK.CGl Condensing Unit Guard size 100-140 including RXYSQ £347.00

Accessories:

cooling heatingRZQG -15°C -20°CRZQsG -5°C -15°CRZQ -5°C -15°C

Notes: i) Replacement technology not applicable

to RZQ200 and RZQ250

ii) All fan coil units standard with auto restart after power failure

iii) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock

iv) All fan coils supplied as standard with air filter

v) Minimum ambient operating temperatures:

vi) FDQ Fan Coil unit requires a separate 15 amp power supply

Page 36: Daikin AC Price List 2013

Integrated Solutions34

Split

, Sky

Air

Hea

t Pum

ps

Multi Series Inverters offer the ability to connect up to 5 fan coils to one outdoor unit. With the MXS range it is possible to install indoor units throughout a house or small commercial premises and only use 1 outdoor unit. Each indoor unit will have it’s own controller.

Multi Series

Heating & coolingconnectable Indoor Units

wall mounted Floor standing Flexi type Round flow cassette

Fully flat cassette

concealed ceiling ceiling suspended

FTXG-J cTXs-K FTXs-K FTXs-G FTX-JV FVXG-K FVXs-F FLXs-B FcQG-F FFQ-c FDXs-F FBQ-c8 FhQ-c

25 35 50 15 35 20 25 35 42 50 60 71 20 25 35 25 35 50 25 35 50 25 35 50 60 35 50 60 25 35 50 60 25 35 50 60 25 35 50 60 35 50 60

2MXS40H ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

2MXS50H ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

3MXS40K ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

3MXS52E ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

3MXS68G ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

4MXS68F ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

4MXS80E ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

5MXS90E ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Outdoor Unit Indoor Unit Cooling Mode Heating Mode

SEER Energy efficiency

class

Annual energy consumption

kWh/a

Design load PDesign kW

SCOP Energy efficiency

class

Annual electricity

consumption kWh/a

Design load PDesign at -10°C kW

Declared heating capacity at -10°C

Back up heating capacity

2MXS40H3V1B 2 x FTXS20K2V1B 6.61 A++ 212 4.0 4.12 A+ 1029 3.1 2.5 0.62MXS50H3V1B 2 x FTXS25K2V1B 6.61 A++ 265 5.0 4.00 A+ 1466 4.2 3.4 0.83MXS40K3V1B 2 x FTXS20K2V1B 6.9 A++ 203 4.0 4.05 A+ 1641 4.8 3.9 0.93MXS52E4V1B 2 x CTXS15K2V1B,

1 x FTXS20K2V1B7.15 A++ 245 5.0 4.31 A+ 1605 5.0 4.0 1.0

3MXS68G3V1B 1 x CTXS15K2V1B, 2 x FTXS20K2V1B

5.34 A 446 6.8 4.00 A+ 1868 5.4 4.4 1.0

4MXS68F3V1B 2 x CTXS15K2V1B, 2 x FTXS20K2V1B

5.68 A+ 420 6.8 4.15 A+ 1953 5.8 4.7 1.1

4MXS80E3V3B 3 x CTXS15K2V1B, 1 x FTXS35K2V1B

6.16 A++ 416 7.4 4.00 A+ 2194 6.3 5.1 1.2

5MXS90E3V3B 2 x CTXS15K2V1B, 3 x FTXS20K2V1B

6.42 A++ 424 7.8 4.19 A+ 2161 6.5 5.3 1.2

For seasonal data in combination with other indoor units, please consult www.daikineurope.com/energylabel

emura wall Mounted Fan coil Units FTXG25Jw FTXG35Jw FTXG50Jw FTXG25Ja FTXG35Ja FTXG50JaTrade Fan coil Unit Price £271.00 £304.00 £464.00 £323.00 £362.00 £554.00

wall Mounted Fan coil Units cTXs15K FTXs20K FTXs25K FTXs35K FTXs42K FTXs50K FTXs60G FTXs71GTrade Fan coil Unit Price £143.00 £151.00 £162.00 £185.00 £208.00 £288.00 £294.00 £392.00

wall Mounted Low Inverter Fan coil Units FTX20JV FTX25JV FTX35JVTrade Fan coil Unit Price £121.00 £133.00 £151.00

Flexi Fan coil Units FLXs25B FLXs35B FLXs50B FLXs60BTrade Fan coil Unit Price £369.00 £415.00 £450.00 £495.00

Nexura Floor standing Fan coil Units FVXG25K FVXG35K FVXG50KTrade Fan coil Unit Price £619.00 £666.00 £729.00

Floor standing Fan coil Units FVXs25F FVXs35F FVXs50FTrade Fan coil Unit Price £513.00 £553.00 £604.00

compact Roundflow cassette Fan coil Units FcQG35F FcQG50F FcQG60FTrade Fan coil Unit Price £703.00 £720.00 £766.00

600 sq 600 sq 4-way blow cassette Fan coil Units FFQ25c FFQ35c FFQ50c FFQ60cTrade Fan coil Unit Price £649.00 £712.00 £786.00 £832.00

ceiling suspended Fan coil Units FhQ35c FhQ50c FhQ60cTrade Fan coil Unit Price £696.00 £754.00 £828.00

Ducted Fan coil Units FDBQ25B FBQ35c8 FBQ50c8 FBQ60c8Trade Fan coil Unit Price £415.00 £536.00 £563.00 £626.00

slim Ducted Fan coil Units FDXs25F FDXs35F FDXs50F FDXs60FTrade Fan coil Unit Price £386.00 £432.00 £467.00 £513.00

Multi Split & Mini VRV® Fan Coils

Notes: i) Accessories for fan coils - refer to pair

system pages

ii) All fan coil units standard with auto restart after power failure

iii) All fan coil units supplied as standard with remote controller

iv) FDXS fan coil units supplied as standard with air filter

v) 2MXS40-50H can only be used with FTXG, FTXS, FTX, FDXS, FVXG, FVXS, FlXS fan coil units

Page 37: Daikin AC Price List 2013

Price List 2013 35

Split

, Sky

Air

Hea

t Pum

ps

Multi Series InvertersMXS-E/F/G/H/K

outdoor Units 2MXs40h 2MXs50h 3MXs40K 3MXs52e 3MXs68G 4MXs68F 4MXs80e 5MXs90eCapacity Nominal Cooling kW 4.00 5.00 4.00 5.20 6.80 6.80 8.00 9.00

Nominal Heating kW 4.40 5.70 4.60 6.80 8.60 8.60 9.60 10.40Dimensions Height mm 550 550 735 735 735 735 770 770

Width mm 765 765 936 936 936 936 900 900Depth mm 285 285 300 300 300 300 320 320

Weight kg 38 42 49 49 58 58 72 73Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps Refer to Multi Combination TablesStarting Current amps 4 4 4 4 4 4 4 4Fuse Rating amps 16 16 16 20 20 20 20 20

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 1.2 1.6 2.0 2.0 2.6 2.6 3.0 3.0

Sound Pressure High dBA 47 48 46 47 48 49 49 52Piping limits Maximum length m 30 30 50 50 60 60 70 75

Maximum Vertical Rise m 15 15 15 15 15 15 15 15Piping Connections liquid inches 2x 1/4 2x 1/4 3x 1/4 3x 1/4 3x 1/4 4x 1/4 4x 1/4 5x 1/4

Gas inches 2x 3/8 3/8 1/2 2x3/8 1/2 2x3/8 1/2 3/8 2x1/2 2x3/8 2x1/2 3/8 1/2 2x5/8 2x3/8 1/2 2x5/8Number of Connected indoor Units 2 2 3 3 3 4 4 5

Trade condensing Unit Price £978.00 £1,082.00 £1,020.00 £1,133.00 £1,605.00 £1,731.00 £1,950.00 £2,099.00

Notes:i) Minimum ambient operating temperatures:

cooling heating2MXs40, 50 10°C -15°C3MXs40, 52, 68 -10°C -15°C4MXs68, 80 -10°C -15°C5MXs90 -10°C -15°C

accessory Ref Description Trade PriceUK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.CGM Condensing Unit Guard size 42-71 £290.00

Accessories:

Mini VRV® for Residential ApplicationsRXYSQ-P8

outdoor Units RXYsQ4P8V1 RXYsQ5P8V1 RXYsQ6P8V1Capacity Nominal Cooling kW 12.60 14.00 15.50

Nominal Heating kW 14.20 16.00 18.00Dimensions Height mm 1345 1345 1345

Width mm 900 900 900Depth mm 320 320 320

Weight kg 120 120 120Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps Refer to Multi Combination TablesStarting Current amps 4 4 4Fuse Rating amps 32 32 32

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 4.0 4.0 4.0

Sound Pressure High dBA 50 51 53Sound Power High dBA 66 67 69Piping limits Maximum length m 115 135 145

Maximum Vertical Rise m data book data book data bookPiping Connections liquid inches 3/8 3/8 3/8

Gas inches 5/8 5/8 3/4Capacity index limit 50~130 62.5~162.5 70~182Number of Connected indoor Units 8 10 13

Trade condensing Unit Price £2,681.00 £3,014.00 £3,364.00

Notes:i) Minimum ambient operating temperatures:

cooling heatingRXYsQ-P8 -5°C -20°C

Please note: RXYSQunitsaresubjecttoVRV®discountlevel

accessory Ref Description Trade PriceBPMKS967A2 Branch Provider Kit - 2 fan coil units £349.00 BPMKS967A3 Branch Provider Kit - 3 fan coil units £372.00 KHRQ22M20T R410a 2 Pipe Refnet Joint £28.00

Accessories:

Page 38: Daikin AC Price List 2013

Integrated Solutions36

Split

, Sky

Air

Hea

t Pum

ps

wall Mounted Fan coil Units FaQ71c FaQ100cTrade Fan coil Unit Price £783.00 £846.00

ceiling suspended Fan coil Units FhQ35c FhQ50c FhQ60c FhQ71c FhQ100c FhQ125cTrade Fan coil Unit Price £696.00 £754.00 £828.00 £969.00 £1,030.00 £1,289.00

compact Roundflow cassette Fan coil Units FcQG35F FcQG50F FcQG60F FcQG71F FcQG100F FcQG125FTrade Fan coil Unit Price £703.00 £720.00 £766.00 £812.00 £921.00 £1,007.00

high coP Roundflow cassette Fan coil Units FcQhG71F FcQhG100F FcQhG125FTrade Fan coil Unit Price £812.00 £921.00 £1,007.00

600 sq 4-way Blow cassette Fan coil Units FFQ35c FFQ50c FFQ60cTrade Fan coil Unit Price £712.00 £786.00 £832.00

Under ceiling 4-way Blow cassette Fan coil Units FUQ71c FUQ100c FUQ125cTrade Fan coil Unit Price £897.00 £984.00 £1,087.00

Dc Ducted Fan coil Units FBQ35c8 FBQ50c8 FBQ60c8 FBQ71c8 FBQ100c8 FBQ125c8Trade Fan coil Unit Price £536.00 £563.00 £626.00 £899.00 £941.00 £1,114.00

slim Ducted Fan coil Units FDXs35F FDXs50F FDXs60FTrade Fan coil Unit Price £432.00 £467.00 £513.00

high static Ducted Fan coil Units FDQ125cTrade Fan coil Unit Price £1,219.00

Twin, Triple and Double Twin Outdoor UnitsPossible Combinations

outdoor Units Nominal cooling kw Nominal heating kw Possible combinations Model TypesRZQG71l8V1 / Y1 6.80 7.50 35 + 35 FFQ, FCQ, FBQ, FDXS, FHQRZQSG71l8V1 / Y1 6.80 7.50 35 + 35 FFQ, FCQ, FBQ, FDXS, FHQRZQG100l8V1 / Y1 9.50 10.80 50 + 50 FFQ, FCQ, FBQ, FDXS, FHQRZQG100l8V1 / Y1 9.50 10.80 35 + 35 + 35 FFQ, FCQ, FBQ, FDXS, FHQRZQSG100l8V1 / Y1 9.50 10.80 50 + 50 FFQ, FCQ, FBQ, FDXS, FHQRZQSG100l8V1 / Y1 9.50 10.80 35 + 35 + 35 FFQ, FCQ, FBQ, FDXS, FHQRZQG125l8V1 / Y1 12.00 13.50 60 + 60 FFQ, FCQG, FBQ, FDXS, FHQRZQG125l8V1 / Y1 12.00 13.50 50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQRZQG125l8V1 / Y1 12.00 13.50 35 + 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQRZQSG125l8V1 / Y1 12.00 13.50 60 + 60 FFQ, FCQG, FBQ, FDXS, FHQRZQSG125l8V1 / Y1 12.00 13.50 50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQRZQSG125l8V1 / Y1 12.00 13.50 35 + 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQRZQG140l7V1 / lY1 13.40 15.50 71 + 71 FCQG, FCQHG, FBQ, FHQ, FUQ, FAQRZQG140l7V1 / lY1 13.40 15.50 50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQRZQG140l7V1 / lY1 13.40 15.50 35 + 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQRZQSG140lV1 / lY1 13.40 15.50 71 + 71 FCQG, FCQHG, FBQ, FHQ, FAQRZQSG140lV1 / lY1 13.40 15.50 50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQRZQSG140lV1 / lY1 13.40 15.50 35 + 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQRZQ200 19.50 23.40 100 + 100 FCQG, FCQHG, FBQ, FHQ, FUQ, FAQRZQ200 19.50 23.40 60 + 60 + 60 FFQ, FCQG, FBQ, FDXS, FHQRZQ200 19.50 23.40 71 + 71 + 71 FCQG, FCQHG, FBQ, FHQ, FUQ, FAQRZQ200 19.50 23.40 50 + 50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQRZQ250 25.00 27.00 125 + 125 FCQG, FCQHG, FBQ, FHQ, FUQ, FDQRZQ250 25.00 27.00 60 + 60 + 60 + 60 FFQ, FCQG, FBQ, FDXS, FHQ

Notes:These systems allow a mixture of fan coil types and sizes on the same condensing unit. Each system is operated on the Master and Slave principle from one remote controller.

As the number of possible combinations is so great, we are unable to show each system as separate prices within the price list.

To calculate a system price please refer to the next pages for individual fan coil and condensing unit prices and remember to add the pipework joints listed as accessory items on the following pages.

Each fan coil unit includes within its price for a remote controller. As a complete system requires only one controller, you will need to subtract the controller cost from all but one fan coil on each system.

EXAMPLE: TRADE EACH TRADE TOTALHeat pump triple system using the following: 3 No FCQG71-F Fan coil units £812.00 £2,436.001 No RZQ200C Condensing unit £2,862.00 £2,862.001 No KHRQ250H7 Pipework branch kit £79.00 £79.002 No BRC1E52A Remote controller (Credit) -£74.00 -£148.00 ToTaL £5,229.00

Twin, Triple and Double Twin Outdoor UnitsFan Coils

Notes:i) Each of the fan coil units includes one remote controller BRC1E52A

ii) FBQ50C to 71C fan coil units require a separate 1 ph power supply when connected to RZQ200 and 250C

iii) Self cleaning deco-panel BYCQ140DG is compatible on cassettes used in twin, triple and double twin applications

iv) For seasonal data on Twin, Triple and Double Twin applications please consult www.daikineurope.com/energylabel

v) Accessories for fan coils and condensing units - refer to pair system pages

Page 39: Daikin AC Price List 2013

Price List 2013 37

Split

, Sky

Air

Hea

t Pum

ps

Seasonal Smart InverterRZQG

outdoor Units seasonal smart Inverter seasonal smart Inverter super Invertersingle Phase 3 Phase

RZQG 71L8V1

RZQG 100L8V1

RZQG 125L8V1

RZQG 140L7V1

RZQG-71L8Y1

RZQG-100L8Y1

RZQG-125L8Y1

RZQG-140LY1

RZQ200c RZQ250c

Dimensions Height mm 990 1430 1430 1430 990 1430 1430 1430 1680 1680Width mm 940 940 940 940 940 940 940 940 930 930Depth mm 320 320 320 320 320 320 320 320 765 765

Weight kg 78 102 102 102 80 101 101 101 183 184Electrical Details Power Supply 1ph 3ph 3ph

Running Current A data book data book data bookStarting Current A 4 4 4 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 16 20 20 20 25 25

interconnection Wiring Core / Cable size 3+E / 1.5Piping Connections liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 7/8 1/2 / 7/8Pipework Maximum length m 50 75 75 75 50 75 75 75 100 100

Maximum Vertical Rise m 30Precharged to m 30Additional Charge g/m Refer to installation ManualHolding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0 8.3 9.3

Sound Pressure High dBA 48 50 51 52 48 50 51 52 57 57

Trade condensing Unit Price £1,168.00 £1,484.00 £1,633.00 £1,864.00 £1,203.00 £1,553.00 £1,709.00 £1,963.00 £2,862.00 £2,998.00

accessory Ref Description Trade PriceKHRQ22M20T R410a 2 Pipe Refnet Joint £28.00 KHRQ127H Triple Refnet Joint - RZQS71~140,RZQ100~140 £63.00 KHRQ250H7 Triple Refnet Joint - RZQ200~250 £79.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £45.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £57.00 UK.CGM Condensing Unit Guard size 42-71 £290.00 UK.CGl Condensing Unit Guard size 100-140 including RXYSQ £347.00

Accessories: Notes:i) Accessories for fan coils and condensing

units - refer to pair system pages

Seasonal Classic InverterRZQSG

outdoor Units seasonal classic Inverter seasonal classic Invertersingle Phase 3 Phase

RZQsG71L3V1 RZQsG100L8V1 RZQsG125L8V1 RZQsG140LV1 RZQsG100L8Y1 RZQsG125L8Y1 RZQsG140LY1Dimensions Height mm 770 990 990 1430 990 990 1430

Width mm 900 940 940 940 940 940 940Depth mm 320 320 320 320 320 320 320

Weight kg 67 81 81 102 82 82 101Electrical Details Power Supply 1ph 3ph

Running Current A data book data bookStarting Current A 4 4 4 4 4 4 4Max Fuse Size A 20 32 32 32 20 20 20

interconnection Wiring Core / Cable size 3+E / 1.5Piping Connections liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8Pipework Maximum length m 30 50 50 50 50 50 50

Maximum Vertical Rise m 15Precharged to m 30Additional Charge g/m Refer to installation ManualHolding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0

Sound Pressure High dBA 49 53 54 53 53 54 53

Trade condensing Unit Price £864.00 £1,196.00 £1,312.00 £1,461.00 £1,232.00 £1,351.00 £1,505.00

accessory Ref Description Trade PriceKHRQ22M20T R410a 2 Pipe Refnet Joint £28.00 KHRQ127H Triple Refnet Joint - RZQS71~140,RZQ100~140 £63.00 KHRQ250H7 Triple Refnet Joint - RZQ200~250 £79.00 UK.CWB90-2 Condensing unit bracket - up to size 71 £36.00 UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 £45.00 UK.DT1 Condensate drip tray for use with UK.CWB90-2 £54.00 UK.DT2 Condensate drip tray for use with UK.CWB140-2 £57.00 UK.CGM Condensing Unit Guard size 42-71 £290.00 UK.CGl Condensing Unit Guard size 100-140 including RXYSQ £347.00

Accessories: Notes:i) Accessories for fan coils and condensing

units - refer to pair system pages

Page 40: Daikin AC Price List 2013

Integrated Solutions38

Split

, Sky

Air

Hea

t Pum

ps

energy

savings up to

72%

air

separation

eFFiCienCy

up to

85%paybaCk time

less than

1.5years

Air curtains for light commercial applicationsBiddle Standard air curtains are the ideal solution for retailers and consultants to combat the issue of climate separation across their outlet or office doorway.

Using a combination of rectifier technology, optimised air velocity and temperature control they deliver greater comfort to staff and customers alike, all year round, in all weathers.

In conjunction with Biddle, Daikin now offer the top air curtain to the market, coupling the benefits of the Biddle air curtain technology with the benefits of the Daikin heat pump inverter technology.

Biddle Standard air curtains are connected to selected Daikin ERQ heat pump inverter condensing units offering:

•Wide capacity range for maximum application potential plus flexible control options

•R-410A refrigerant, single and 3 phase

•Wideoperationrange:-5~46°Cincoolingand-20~15.5°Cinheating

Air Curtains

Small Air Curtains: Free Hanging, Cassette and Recessed

F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air outlet

accessory Ref Description Trade PriceBRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock £74.00 KRCS01-1 Remote room mounted temperature sensor £45.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV Poa

Matching air cooled condensing Units

single Phase Three PhaseeRQ100aV1 eRQ125aV1 eRQ140aV1 eRQ125aw1 eRQ200aw1 eRQ250aw1

Trade Unit Price £1,503.00 £1,675.00 £2,009.00 £1,709.00 £3,207.00 £3,341.00CYQS150DK80*BN •CYQS200DK100*BN • •CYQS250DK140*BN • • • •

Accessories: Notes:i) Please refer to page 40 for ERQ features

and specifications

ii) To calculate the price for a complete system, add together the prices of the Air Curtain, ERQ condensing unit and remote controller as below example:

1 No CYQS150DK80FBN £3,564.00

1 No ERQ100AV1 £1,503.00 1 No BRC1E52A £74.00

ToTaL £5,141.00

BIDDLe sTaNDaRD aIR cURTaIN - sMaLL cYQs150DK80*BN cYQs200DK100*BN cYQs250DK140*BN* = F * = c * = R * = F * = c * = R * = F * = c * = R

Heating Capacity speed 3 kW 9.00 11.60 16.20Delta T inlet = room temperature speed 3 k 15 15 16Power input (50Hz) Fan only / Heating kW 0.35 / 0.35 0.46 / 0.46 0.58 / 0.58Maximum Door Width m 1.50 2.00 2.50Mounting Height *2 Max / Min m 2.7/2.0 2.7/2.0 2.7/2.0Dimensions Height mm 270 270 270 270 270 270 270 270 270

Width mm 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548Depth mm 590 821 561 590 821 561 590 821 561

Weight kg 66 83 88 83 102 108 107 129 137Casing Colour white RAl9010 white RAl9010 white RAl9010Minimum requiring ceiling void mm 420 420 420Fan - Air Flow Rate Heating speed 3 m3/sec 0.485 0.647 0.808Sound Pressure Heating speed 3 dBA 49 50 51Refrigerant Type R-410A R-410A R-410APiping Connections liquid (oD) / Gas mm 9.52/16.0 9.52/16.0 9.52/19.0Power Supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50

Trade Unit Price £3,564.00 £3,564.00 £3,756.00 £4,355.00 £4,355.00 £4,701.00 £4,867.00 £4,867.00 £5,268.00

Page 41: Daikin AC Price List 2013

Price List 2013 39

Split

, Sky

Air

Hea

t Pum

ps

Medium Air Curtains: Free Hanging, Cassette and Recessed

F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air outlet

accessory Ref Description Trade PriceBRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock £74.00 KRCS01-1 Remote room mounted temperature sensor £45.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV Poa

single Phase Three PhaseeRQ100aV1 eRQ125aV1 eRQ140aV1 eRQ125aw1 eRQ200aw1 eRQ250aw1

Trade Unit Price £1,503.00 £1,675.00 £2,009.00 £1,709.00 £3,207.00 £3,341.00CYQM100DK80*BN •CYQM150DK80*BN • •CYQM200DK100*BN • • •CYQM250DK140*BN • •

Accessories: Notes:i) Please refer to page 40 for ERQ features

and specifications

ii) To calculate the price for a complete system, add together the prices of the Air Curtain, ERQ condensing unit and remote controller as below example:

1 No CYQM150DK80FBN £4,117.00

1 No ERQ125AV1 £1,675.00 1 No BRC1E52A £74.00

ToTaL £5,866.00

BIDDLe sTaNDaRD aIR cURTaIN - MeDIUM cYQM100DK80*BN cYQM150DK80*BN cYQM200DK100*BN cYQM250DK140*BN* = F * = c * = R * = F * = c * = R * = F * = c * = R * = F * = c * = R

Heating Capacity speed 3 kW 9.20 11.00 13.40 19.90Delta T inlet = room temperature speed 3 k 17 14 13 15Power input (50Hz) Fan only / Heating kW 0.37 / 0.37 0.56 / 0.56 0.75 / 0.75 0.94 / 0.94Maximum Door Width m 1.00 1.50 2.00 2.50Mounting Height *2 Max / Min m 3.2/2.3 3.2/2.3 3.2/2.3 3.2/2.3Dimensions Height mm 270 270 270 270 270 270 270 270 270 270 270 270

Width mm 1,000 1,000 1,048 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548Depth mm 590 821 561 590 821 561 590 821 561 590 821 561

Weight kg 57 68 66 73 88 93 94 111 117 108 136 144Casing Colour white RAl9010 white RAl9010 white RAl9010 white RAl9010Minimum requiring ceiling void mm 420 420 420 420Fan - Air Flow Rate Heating speed 3 m3/sec 0.446 0.669 0.892 1.115Sound Pressure Heating speed 3 dBA 50 51 53 54Refrigerant Type R-410A R-410A R-410A R-410APiping Connections liquid (oD) / Gas mm 9.52/16.0 9.52/16.0 9.52/16.0 9.52/19.0Power Supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50 1~/230/50

Trade Unit Price £3,455.00 £3,455.00 £3,566.00 £4,117.00 £4,117.00 £4,307.00 £5,155.00 £5,155.00 £5,520.00 £5,902.00 £5,902.00 £6,295.00

Large Air Curtains: Free Hanging, Cassette and Recessed

F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air outlet

accessory Ref Description Trade PriceBRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock £74.00 KRCS01-1 Remote room mounted temperature sensor £45.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV. Poa

single Phase Three PhaseeRQ100aV1 eRQ125aV1 eRQ140aV1 eRQ125aw1 eRQ200aw1 eRQ250aw1

Trade Unit Price £1,503.00 £1,675.00 £2,009.00 £1,709.00 £3,207.00 £3,341.00CYQl100DK125*BN • • • •CYQl150DK200*BN • •CYQl200DK250*BN •CYQl250DK250*BN •

Accessories: Notes:i) Please refer to page 40 for ERQ features

and specifications

ii) To calculate the price for a complete system, add together the prices of the Air Curtain, ERQ condensing unit and remote controller as below example:

1 No CYQl100DK125FBN £3,942.00

1 No ERQ125AV1 £1,675.00 1 No BRC1E52A £74.00

ToTaL £5,691.00

BIDDLe sTaNDaRD aIR cURTaIN - LaRGe cYQL100DK125*BN cYQL150DK200*BN cYQL200DK250*BN cYQL250DK250*BN* = F * = c * = R * = F * = c * = R * = F * = c * = R * = F * = c * = R

Heating Capacity speed 3 kW 15.60 23.30 29.40 31.10Delta T inlet = room temperature speed 3 k 15 15 14 12Power input (50Hz) Fan only / Heating kW 0.75 / 0.75 1.13 / 1.13 1.50 / 1.50 1.88 / 1.88Maximum Door Width m 1.00 1.50 2.00 2.50Mounting Height *2 Max / Min m 3.7/2.5 3.7/2.5 3.7/2.5 3.7/2.5Dimensions Height mm 370 370 370 370 370 370 370 370 370 370 370 370

Width mm 1,000 1,000 1,048 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548Depth mm 774 1105 745 774 1105 745 774 1105 745 774 1105 745

Weight kg 76 81 83 100 118 141 126 151 155 157 190 196Casing Colour white RAl9010 white RAl9010 white RAl9010 white RAl9010Minimum requiring ceiling void mm 520 520 520 520Fan - Air Flow Rate Heating speed 3 m3/sec 0.861 1.292 1.722 2.153Sound Pressure Heating speed 3 dBA 53 54 56 57Refrigerant Type R-410A R-410A R-410A R-410APiping Connections liquid (oD) / Gas mm 9.52/16.0 9.52/19.0 9.52/22.0 9.52/22.0Power Supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50 1~/230/50

Trade Unit Price £3,942.00 £3,942.00 £3,953.00 £5,624.00 £5,624.00 £5,805.00 £6,981.00 £6,981.00 £7,344.00 £8,148.00 £8,148.00 £8,597.00

Page 42: Daikin AC Price List 2013

Integrated Solutions40

Split

, Sky

Air

Hea

t Pum

ps

For central ducted distribution systems Daikin have the solution for providing cooling and heating of the air, enabling optimal comfort and efficiency.

Even without the benefit of individual room control, the system can provide a flexible energy saving answer over traditional methods through the incorporation of inverter control and heat pump technology.

The following pages include Packaged Heat Pump Rooftop systems, with optional economisers, to heat pump condensing units and connection kits for use with other manufacturers heating and cooling coils.

Central Ducted Solutions

outdoor unit Trade Unit Price control box expansion Valve Kitcontrol z control y control xl class 63 class 80 class 100 class 125 class 140 class 200 class 250eKeQDcB eKeQFcB eKeQDcB/RTD eKeXV63 eKeXV80 eKeXV100 eKeXV125 eKeXV140 eKeXV200 eKeXV250

Coil Volume dm3 min 1.66 2.09 2.65 3.31 4.13 4.63 6.61 max 2.08 2.64 3.30 4.12 4.62 6.60 8.25

1ph ERQ100AV1 £1,503.00 P P P P P P P - - -ERQ125AV1 £1,675.00 P P P P P P P P - -ERQ140AV1 £2,009.00 P P P - P P P P - -

3ph ERQ125AW1 £1,709.00 P P P P P P P P - -ERQ200AW1 £3,207.00 P P P - - P P P P PERQ250AW1 £3,341.00 P P P - - - P P P P

Trade acc. Price £335.00 £357.00 £556.00 £95.00 £101.00 £76.00 £88.00 £99.00 £117.00 £129.00

Air Cooled Heat Pump InverterCondensing Unit Kit for DX Coil

P: Pair Combination depending on air handling units coils volume X: Possibility to connect Control xl includes UK.RTD-20

a new range of R410a inverter condensing units for pair application with air handling units:• Inverter controlled heat pump units

• Large capacity range (from 63 to 250 class)

• Ventilation and air conditioning in 1 solution

•EKEXV-kit&controlboxesaredesignedforoutdoorinstallation and can be wall mounted

• Per EKEXV-kit/control box, only 1 air handling unit coil can be connected

•Outdoorunitoperationrange:-5°CDB~43°CDB

Flexible control possibilities:control xl:Full external control from 3rd party temperature controller with volt free remote enable contact and linear variable capacity control output

control y:External control from 3rd party temperature controller with volt free remote enable contact. Fixed evaporating temperature selection, range: +3°C to +10°C

control z (BRc1D52 required):Control via Daikin BRC1D52 remote controller and return air or remote sensor (KRCS01-1 optional). A volt free remote enable contact is required to confirm fan operation status. For re-circ applications only

Liquid pipe

Gas pipe

Liquid pipe

Gas pipe

EV kit

Air handling unit

Field supply

Control boxF1,F2 communication

DDC control (control x)

Page 43: Daikin AC Price List 2013

Price List 2013 41

Split

, Sky

Air

Hea

t Pum

ps

Large Condensing Units ERAD-E

Features:

Large condensing Unit (standard Noise Level)eRaD120e-ss eRaD140e-ss eRaD170e-ss eRaD200e-ss eRaD220e-ss eRaD250e-ss eRaD310e-ss eRaD370e-ss eRaD440e-ss eRaD490e-ss

Capacity Nominal Cooling kW 121 144 165 196 219 252 306 370 435 488EER 2.89 2.82 2.87 3.01 2.97 3.29 3.3 3.03 2.96 3.03Refrigerant R134aDimensions length mm 2170 2170 3070 3070 3070 3070 3070 3070 3070 3070

Height mm 2.27 2.27 2.27 2.27 2.27 2.27 2220 2220 2220 2220Width mm 1290 1290 1290 1290 1290 1290 2240 2240 2240 2240

Weight kg 1564 1587 1698 1739 1886 1928 2355 2559 2642 2677Electrical Details Power Supply V 400

Hz 50ph 3

Trade Unit Price Poa Poa Poa Poa Poa Poa Poa Poa Poa Poa

Large condensing Unit (Low Noise Level)eRaD120e-sL eRaD140e-sL eRaD160e-sL eRaD190e-sL eRaD210e-sL eRaD240e-sL eRaD300e-sL eRaD350e-sL eRaD410e-sL eRaD460e-sL

Capacity Nominal Cooling kW 116 137 159 187 209 243 295 352 409 462EER 2.74 2.61 2.76 2.82 2.83 3.11 3.22 2.88 2.72 2.76Refrigerant R134aDimensions length mm 2170 2170 3070 3070 3070 3070 3070 3070 3070 3070

Height mm 2.27 2.27 2.27 2.27 2.27 2.27 2220 2220 2220 2220Width mm 1290 1290 1290 1290 1290 1290 2240 2240 2240 2240

Weight kg 1712 1738 1851 1897 2046 2091 2534 2741 2834 2873Electrical Details Power Supply V 400

Hz 50ph 3

Trade Unit Price Poa Poa Poa Poa Poa Poa Poa Poa Poa Poa

ERAD-E are a range of cooling only R134a condensing units for pair application with air handling units• Largecapacityrange100kWto410kW • SuperiorcontrollogicusingthenewMicroTechIIIcontroller

• Singlecircuitunits • Screwcompressorwithcapacitycontroldownto25% • Availableinbothstandardandlownoiseconfigurations Please contact your sales office for further information on these products

Rooftop Packaged Unit – Heat Pump UATYQ

Notes:i) Minimum Ambient operating conditions ii) Supplied with remote controller as standard

iii) Economiser option is supplied as a kit for site assembly

iv) low ambient kit for models UATYPC available on request

v) Please check stock & delivery period for all model sizes

vi) Standard delivery for all units does not include off-loading to kerbside

vii) UATYQ250/350 can be off-loaded by fork-lift if there is one at site

viii) All other units require crane or HiAB. Prices for HiAB available on request

cooling heatingUaTYQ250~700 0°C -15°CUaTYPc10~12 20°C -15°C

UaTYQ250cY1 UaTYQ350cY1 UaTYQ450cY1 UaTYQ550cY1 UaTYQ600cY1 UaTYQ700cY1 UaTYPc10aY1 UaTYPc12aY1Capacity Nominal Cooling kW 27.34 35.58 44.72 55.69 66.82 72.60 101.10 109.60

Nominal Heating kW 24.91 34.79 41.79 53.93 61.69 69.61 102.30 126.30Dimensions Height mm 1150 1028 1130 1048 1302 1302 1974 1974

Width mm 1638 2209 2209 2209 2209 2209 2252 2252Depth mm 2063 2113 2113 2670 2670 2670 3180 3180

Weight kg 490 660 690 780 830 970 1510 1600Air Flow Rate indoor m3/min 93 122 160 190 205 233 312 354External Static indoor Pa 147 147 147 206 206 206Air Flow Rate outdoor m3/min 0 0 0 0 0 0 0 0Refrigerant R410a R407CSound Power level outdoor dBA 82 83 83 87 90 90 80 80Drain size mm 25.4 (oD)Electrical Details Power Supply V 400

Hz 50Phase 3ph

Running Current A 20.5 26.4 33.1 39.4 41.6 46.5 74.2 82.9Starting Current A 118 93 123 137 144 148 175 , 215 215x2Max Fuse Size A 32 40 40 50 50 50 125 125

Trade Unit Price £4,928.00 £5,131.00 £8,443.00 £9,290.00 £9,990.00 £10,690.00 £14,274.00 £15,506.00

economiser ecoNo250aY1 ecoNo350aY1 ecoNo450aY1 ecoNo550aY1 ecoNo600aY1 ecoNo700aY1Trade Unit Price £868.00 £912.00 £956.00 £1,003.00 £1,054.00 £1,106.00

Page 44: Daikin AC Price List 2013

Integrated Solutions42

Split

, Sky

Air

Hea

t Pum

ps

Page 45: Daikin AC Price List 2013

43

VRV®

scotland Region

0845 641 9330

Northern Region

0845 641 9340

Midlands Region

0845 641 9370

western Region

0845 641 9320

North London

0845 641 9360

south London

0845 641 9355

VRV®Indoor Units 44

VRV®FanCoilUnits 44

Air Curtains 52

Hot Water Connection 54

outdoor condensing Units 57

VRV®CondensingUnits–HeatPumpMini 57

VRV®CondensingUnits–HeatPump 58

VRV®CondensingUnits–HeatRecovery 62

VRV®CondensingUnits–HeatRecoveryHotWater 66

VRV®CondensingUnits–WaterCooled 66

VRV®CondensingUnits–Geothermal 67

VRV®CondensingUnits–ReplacementVRV®-Q 68

accessories 77

VRV®UnitAccessories

Intelligent Controls

Page 46: Daikin AC Price List 2013

Integrated Solutions

VRV®

44

VRV® Fan Coil – Roundflow CassetteFXFQ-A

Notes:i) Cassette prices include standard decoration panel - self cleaning panel available as an accessory itemii) For accessories please refer to pages 77 - 84

Indoor Units FXFQ20a FXFQ25a FXFQ32a FXFQ40a FXFQ50a FXFQ63a FXFQ80a FXFQ100a FXFQ125aCapacity UK Total Cooling kW 1.80 2.30 2.90 3.60 4.50 5.70 7.20 9.00 11.30

UK Sensible Cooling kW 1.60 2.03 2.53 2.90 3.47 4.47 5.83 6.77 8.37UK Heating kW 1.91 2.44 3.05 3.81 4.80 6.10 7.63 9.53 12.20UK Heating VRViii HR only kW 2.05 2.62 3.28 4.10 5.16 6.56 8.20 10.25 13.12Nominal Cooling kW 2.20 2.80 3.60 4.50 5.60 7.10 9.00 11.20 14.00Nominal Heating kW 2.50 3.20 4.00 5.00 6.30 8.00 10.00 12.50 16.00

Air Flow Rate High m3/sec 0.21 0.21 0.21 0.23 0.25 0.28 0.38 0.44 0.55low m3/sec 0.15 0.15 0.15 0.16 0.18 0.18 0.21 0.21 0.33

Dimensions (with Decoration Panel)

Height mm 204 (264) 204 (264) 204 (264) 204 (264) 204 (264) 204 (264) 246 (306) 246 (306) 288 (348)Width mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)Depth mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)

Weight (with Decoration Panel) kg 19 (24.4) 19 (24.4) 19 (24.4) 20 (25.4) 21 (26.4) 21 (26.4) 24 (29.4) 24 (29.4) 26 (31.4)Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps 0.3 0.3 0.3 0.3 0.4 0.4 0.6 0.8 1.3Fuse Rating amps 5

Sound level Sound Pressure High dBA 31.0 31.0 31.0 33.0 33.0 35.0 38.0 43.0 45.0low dBA 28.0 28.0 28.0 29.0 29.0 30.0 30.0 30.0 36.0

Sound Power dBA 49 49 49 51 51 53 55 60 61Piping Connections liquid inches 1/4 1/4 1/4 1/4 1/4 3/8 3/8 3/8 3/8

Gas inches 1/2 1/2 1/2 1/2 1/2 5/8 5/8 5/8 5/8

Trade Unit Price £744.00 £759.00 £776.00 £838.00 £879.00 £927.00 £989.00 £1,073.00 £1,338.00

Indoor Units FXZQ15a FXZQ20a FXZQ25a FXZQ32a FXZQ40a FXZQ50aCapacity UK Total Cooling kW TBC 1.80 2.30 2.90 3.60 4.50

UK Sensible Cooling kW TBC 1.43 1.70 2.03 2.77 3.43UK Heating kW 1.45 1.91 2.44 3.05 3.81 4.80UK Heating VRViii HR only kW 1.56 2.05 2.62 3.28 4.10 5.16Nominal Cooling kW 1.70 2.20 2.80 3.60 4.50 5.60Nominal Heating kW 1.90 2.50 3.20 4.00 5.00 6.30

Air Flow Rate High m3/sec 0.14 0.15 0.15 0.17 0.19 0.24low m3/sec 0.11 0.11 0.11 0.12 0.13 0.17

Dimensions (with Decoration Panel) HxWxD mm 260 (306) x 575 (620) x 575 (620)Weight (with Decoration Panel) kg 17.5 (20.2) 17.5 (20.2) 17.5 (20.2) 18 (20.7) 18 (20.7) 18 (20.7)Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps 0.6 0.6 0.6 0.6 0.6 0.7Fuse Rating amps 5

Sound level Sound Pressure High dBA 31.5 32.0 33.0 33.5 37.0 43.0low dBA 25.5 25.5 25.5 26.0 28.0 33.0

Sound Power dBA 49 49 50 51 54 60Piping Connections liquid inches 1/4 1/4 1/4 1/4 1/4 1/4

Gas inches 1/2 1/2 1/2 1/2 1/2 1/2

Trade Unit Price £707.00 £722.00 £737.00 £754.00 £809.00 £888.00

VRV® Fan Coil – 600 Sq 4 Way Blow CassetteFXZQ-A (FXZQ-A Series coming summer 2013. FXZQ-M9 series available until release)

Notes:i) Cassette prices include Fully Flat decoration panel in fresh white. other colour panels available on request. ii) For accessories please refer to pages 77 - 84

Page 47: Daikin AC Price List 2013

Price List 2013 45

VRV®

Indoor Units FXcQ20a FXcQ25a FXcQ32a FXcQ40a FXcQ50a FXcQ63a FXcQ80a FXcQ125aCapacity UK Total Cooling kW 1.80 2.30 2.90 3.60 4.50 5.70 TBC TBC

UK Sensible Cooling kW 1.47 1.83 2.23 2.70 3.30 4.07 TBC TBCUK Heating kW 1.91 2.44 3.05 3.81 4.80 6.10 7.63 12.20UK Heating VRViii HR only kW 2.05 2.62 3.28 4.10 5.16 6.56 8.20 13.12Nominal Cooling kW 2.20 2.80 3.60 4.50 5.60 7.10 9.00 14.00Nominal Heating kW 2.50 3.20 4.00 5.00 6.30 8.00 10.00 16.00

Air Flow Rate High m3/sec 0.18 0.19 0.19 0.20 0.25 0.27 0.43 0.53low m3/sec 0.13 0.13 0.13 0.14 0.18 0.19 0.31 0.38

Dimensions (with Decoration Panel)

Height mm 305 (360) 305 (360) 305 (360) 305 (360) 305 (360) 305 (360) 305 (360) 305 (360)Width mm 775 (1070) 775 (1070) 775 (1070) 775 (1070) 990 (1285) 990 (1285) 1445 (1740) 1445 (1740)Depth mm 620 (700) 620 (700) 620 (700) 620 (700) 620 (700) 620 (700) 620 (700) 620 (700)

Weight (with Decoration Panel) kg 19 (29) 19 (29) 19 (29) 19 (29) 22 (33) 25 (36) 33 (44) 38 (51)Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps 0.2 0.2 0.2 0.2 0.3 0.4 0.5 0.9Fuse Rating amps 5

Sound level Sound Pressure High dBA 32.0 34.0 34.0 36.0 37.0 39.0 42.0 46.0low dBA 28.0 29.0 30.0 31.0 31.0 32.0 33.0 38.0

Sound Power dBA tbc tbc tbc tbc tbc tbc tbc tbcPiping Connections liquid inches 1/4 1/4 1/4 1/4 1/4 3/8 3/8 3/8

Gas inches 1/2 1/2 1/2 1/2 1/2 5/8 5/8 5/8

Trade Unit Price £837.00 £852.00 £861.00 £951.00 £1,040.00 £1,080.00 £1,239.00 £1,487.00

VRV® Fan Coil – 2 Way Blow CassetteFXCQ-A

Notes:i) Cassette prices include decoration panelii) For accessories please refer to pages 77 - 84

Indoor Units FXKQ25Ma FXKQ32Ma FXKQ40Ma FXKQ63MaCapacity UK Total Cooling kW 2.30 2.90 3.60 5.70

UK Sensible Cooling kW 2.10 2.40 2.73 4.33UK Heating kW 2.44 3.05 3.81 6.10UK Heating VRViii HR only kW 2.62 3.28 4.10 6.56Nominal Cooling kW 2.80 3.60 4.50 7.10Nominal Heating kW 3.20 4.00 5.00 8.00

Air Flow Rate High m3/sec 0.18 0.18 0.22 0.30low m3/sec 0.15 0.15 0.17 0.25

Dimensions (with Decoration Panel)

Height mm 215 (285) 215 (285) 215 (285) 215 (285)Width mm 1110 (1240) 1110 (1240) 1110 (1240) 1310 (1440)Depth mm 710 (800) 710 (800) 710 (800) 710 (800)

Weight (with Decoration Panel) kg 31 (39.5) 31 (39.5) 31 (39.5) 34 (43.5)Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps 0.2 0.2 0.2 0.4Fuse Rating amps 5

Sound level Sound Pressure High dBA 38.0 38.0 40.0 42.0low dBA 33.0 33.0 34.0 37.0

Sound Power dBA - - - -Piping Connections liquid inches 1/4 1/4 1/4 3/8

Gas inches 1/2 1/2 1/2 5/8

Trade Unit Price £927.00 £937.00 £1,024.00 £1,139.00

VRV® Fan Coil – 1 Way Blow Corner CassetteFXKQ-MA

Notes:i) Cassette prices include decoration panelii) For accessories please refer to pages 77 - 84

Page 48: Daikin AC Price List 2013

Integrated Solutions

VRV®

46

Indoor Units FXhQ32a FXhQ63a FXhQ100aCapacity UK Total Cooling kW 2.90 5.70 9.00

UK Sensible Cooling kW 2.50 4.43 6.67UK Heating kW 3.05 6.10 9.53UK Heating VRViii HR only kW 3.28 6.56 10.25Nominal Cooling kW 3.60 7.10 11.20Nominal Heating kW 4.00 8.00 12.50

Air Flow Rate High m3/sec 0.23 0.33 0.49low m3/sec 0.17 0.23 0.32

Dimensions Height x width x Depth mm 235 x 960 x 690 235 x 1270 x 690 235 x 1590 x 690Weight kg 24 33 39Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps 0.6 0.6 1.3Fuse Rating amps 5

Sound level Sound Pressure High dBA 36.0 37.0 44.0low dBA 31.0 34.0 34.0

Sound Power dBA - - -Piping Connections liquid inches 1/4 3/8 3/8

Gas inches 1/2 5/8 5/8

Trade Unit Price £888.00 £984.00 £1,222.00

VRV® Fan Coil – Ceiling SuspendedFXHQ-A

Notes:i) For accessories please refer to pages 77 - 84

Indoor Units FXUQ71a FXUQ100aCapacity UK Total Cooling kW 6.40 9.00

UK Sensible Cooling kW 5.20 7.10UK Heating kW 6.86 9.53UK Heating VRViii HR only kW 7.38 10.25Nominal Cooling kW 8.00 11.20Nominal Heating kW 9.00 12.50

Air Flow Rate High m3/sec 0.38 0.52low m3/sec 0.27 0.35

Dimensions Height mm 198 198Width mm 950 950Depth mm 950 950

Weight kg 26 27Electrical Details Power Supply Phase 1 ph

Hz 50V 230

Running Current amps 0.5 1.1Fuse Rating amps 5.00

Sound level Sound Pressure High dBA 40.0 47.0low dBA 36.0 40.0

Sound Power dBA tbc tbcPiping Connections liquid inches 3/8 3/8

Gas inches 5/8 5/8

Trade Unit Price £1,229.00 £1,311.00

VRV® Fan Coil – Under Ceiling Cassette FXUQ-A

Notes:i) For accessories please refer to pages 77 - 84

Page 49: Daikin AC Price List 2013

Price List 2013 47

VRV®

Indoor Units FXDQ20M9 FXDQ25M9Capacity UK Total Cooling kW 1.80 2.30

UK Sensible Cooling kW 1.60 1.90UK Heating kW 1.91 2.44UK Heating VRViii HR only kW 2.05 2.62Nominal Cooling kW 2.20 2.80Nominal Heating kW 2.50 3.20

Air Flow Rate High m3/sec 0.11 0.12low m3/sec 0.09 0.10

Dimensions Height x Width x Depth mm 230 x 652 x 502Weight kg 17 17Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps 0.1 0.1Fuse Rating amps 5

Sound level Sound Pressure High dBA 37.0 37.0low dBA 32.0 32.0

Sound Power dBA 50 50Piping Connections liquid inches 1/4 1/4

Gas inches 1/2 1/2

Trade Unit Price £568.00 £585.00

VRV® Fan Coil – Small DuctedFXDQ-M9

Notes:i) For accessories please refer to pages 77 - 84ii) Fan coils supplied as standard with factory fitted filter

Indoor Units FXDQ15a FXDQ20a FXDQ25a FXDQ32a FXDQ40a FXDQ50a FXDQ63aCapacity UK Total Cooling kW TBC 1.80 2.30 2.90 3.60 4.50 5.70

UK Sensible Cooling kW TBC 1.60 1.90 2.30 2.80 3.50 4.30UK Heating kW 1.30 1.91 2.44 3.05 3.81 4.80 6.10UK Heating VRViii HR only kW 1.39 2.05 2.62 3.28 4.10 5.16 6.56Nominal Cooling kW 1.70 2.20 2.80 3.60 4.50 5.60 7.10Nominal Heating kW 1.70 2.50 3.20 4.00 5.00 6.30 8.00

Air Flow Rate High m3/sec 0.13 0.13 0.13 0.13 0.18 0.21 0.28Nom m3/sec 0.12 0.12 0.12 0.12 0.16 0.18 0.24low m3/sec 0.11 0.11 0.11 0.11 0.14 0.17 0.22

External Static Pressure High Pa 30.0 30.0 30.0 30.0 44.0 44.0 44.0low Pa 10.0 10.0 10.0 10.0 15.0 15.0 15.0

Dimensions Height x Width x Depth mm 200 x 750 x 620 200 x 950 x 620 200 x 1150 x 620Weight kg 22 22 22 22 26 26 29Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps 0.3 0.3 0.3 0.3 0.4 0.4 0.5Fuse Rating amps 5

Sound level Sound Pressure Hi Hi dBA 32.0 33.0 33.0 33.0 34.0 35.0 36.0High dBA 31.0 31.0 31.0 31.0 32.0 33.0 34.0low dBA 29.0 29.0 29.0 29.0 28.0 29.0 30.0

Sound Power dBA - - - - - - -Piping Connections liquid inches 1/4 1/4 1/4 1/4 1/4 1/4 3/8

Gas inches 1/2 1/2 1/2 1/2 1/2 1/2 5/8

Trade Unit Price £551.00 £568.00 £585.00 £593.00 £631.00 £657.00 £677.00

VRV® Fan Coil – Slim DuctedFXDQ-A

Notes:i) For accessories please refer to pages 77 - 84ii) Fan coils supplied as standard with factory fitted filter

Page 50: Daikin AC Price List 2013

Integrated Solutions

VRV®

48

Indoor Units FXsQ20P FXsQ25P FXsQ32P FXsQ40P FXsQ50P FXsQ63P FXsQ80P FXsQ100P FXsQ125P FXsQ140PCapacity UK Total Cooling kW 1.80 2.30 2.90 3.60 4.50 5.70 7.20 9.00 11.30 12.90

UK Sensible Cooling kW 1.80 2.00 2.50 3.40 3.90 4.90 6.10 7.30 8.90 10.40UK Heating kW 1.91 2.44 3.05 3.81 4.80 6.10 7.63 9.53 12.20 13.73UK Heating VRViii HR only kW 2.05 2.62 3.28 4.10 5.16 6.56 8.20 10.25 13.12 14.75Nominal Cooling kW 2.20 2.80 3.60 4.50 5.60 7.10 9.00 11.20 14.00 16.00Nominal Heating kW 2.50 3.20 4.00 5.00 6.30 8.00 10.00 12.50 16.00 18.00

Air Flow Rate High m3/sec 0.15 0.15 0.16 0.27 0.27 0.33 0.42 0.53 0.65 0.77low m3/sec 0.11 0.11 0.12 0.18 0.18 0.27 0.33 0.38 0.47 0.53

External Static Pressure High Pa 70.0 70.0 70.0 100.0 100.0 100.0 100.0 120.0 120.0 140.0low Pa 30.0 30.0 30.0 30.0 30.0 30.0 40.0 40.0 40.0 50.0

Dimensions Height x Width x Depth mm 300 x 550 x 700 300 x 700 x 700 300 x 1000 x 700 300 x 1400 x 700Weight kg 23 23 23 26 26 35 35 46 46 47Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps 0.4 0.4 0.4 1.2 1.2 1.1 1.3 1.6 2.1 3.1Fuse Rating amps 5

Sound level Sound Pressure High dBA 32.0 32.0 33.0 37.0 37.0 37.0 38.0 38.0 40.0 42.0low dBA 26.0 26.0 27.0 29.0 29.0 30.0 32.0 32.0 33.0 34.0

Sound Power dBA 55 55 56 63 63 59 63 61 66 67Piping Connections liquid inches 1/4 1/4 1/4 1/4 1/4 3/8 3/8 3/8 3/8 3/8

Gas inches 1/2 1/2 1/2 1/2 1/2 5/8 5/8 5/8 5/8 5/8

Trade Unit Price £586.00 £602.00 £610.00 £649.00 £676.00 £698.00 £796.00 £882.00 £1,010.00 £1,111.00

VRV® Fan Coil – Ducted with Inverter FanFXSQ-P

Notes:i) For accessories please refer to pages 77 - 84ii) Fan coils supplied as standard with factory fitted filter

Indoor Units FXMQ20P7 FXMQ25P7 FXMQ32P7 FXMQ40P7 FXMQ50P7 FXMQ63P7 FXMQ80P7 FXMQ100P7 FXMQ125P7Capacity UK Total Cooling kW TBC TBC TBC 3.60 4.50 5.70 7.20 9.00 11.30

UK Sensible Cooling kW TBC TBC TBC 3.40 4.10 4.90 6.10 7.30 9.20UK Heating kW 1.91 2.44 3.05 3.81 4.80 6.10 7.63 9.53 12.20UK Heating VRViii HR only kW 2.05 2.62 3.28 4.10 5.16 6.56 8.20 10.25 13.12Nominal Cooling kW 2.20 2.80 3.60 4.50 5.60 7.10 9.00 11.20 14.00Nominal Heating kW 2.50 3.20 4.00 5.00 6.30 8.00 10.00 12.50 16.00

Air Flow Rate High m3/sec 0.15 0.15 0.15 0.27 0.30 0.33 0.42 0.53 0.65low m3/sec 0.11 0.11 0.12 0.18 0.25 0.27 0.33 0.38 0.47

External Static pressure High Pa 100.0 100.0 100.0 160.0 200.0 200.0 200.0 200.0 200.0low Pa 50.0 50.0 50.0 100.0 100.0 100.0 100.0 100.0 100.0

Dimensions Height x Width x Depth mm 300 x 550 x 700 300 x 700 x 700

300 x 1000 x 700 300 x 1400 x 700

Weight kg 23 23 23 26 35 35 35 46 46Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps 0.6 0.6 0.6 1.6 1.4 1.4 1.7 2.3 2.9Fuse Rating amps 5

Sound level Sound Pressure High dBA 33.0 33.0 34.0 39.0 41.0 42.0 43.0 43.0 44.0low dBA 29.0 29.0 30.0 35.0 37.0 38.0 39.0 39.0 40.0

Sound Power dBA 56/- 56/- 57/- 65/- 61/- 64/- 67/- 65/- 70/-Piping Connections liquid inches 1/4 1/4 1/4 1/4 1/4 3/8 3/8 3/8 3/8

Gas inches 1/2 1/2 1/2 1/2 1/2 5/8 5/8 5/8 5/8

Trade Unit Price £782.00 £800.00 £826.00 £981.00 £1,045.00 £1,095.00 £1,151.00 £1,275.00 £1,460.00

VRV® Fan Coil – High Static Ducted FXMQ-P7

Notes:i) For accessories please refer to pages 77 - 84

Page 51: Daikin AC Price List 2013

Price List 2013 49

VRV®

Indoor Units FXMQ200Ma FXMQ250MaCapacity UK Total Cooling kW 18.00 22.50

UK Sensible Cooling kW 14.40 17.97UK Heating kW 19.06 24.02UK Heating VRViii HR only kW 20.49 25.82Nominal Cooling kW 22.40 28.00Nominal Heating kW 25.00 31.50

Air Flow Rate High m3/sec 0.97 1.20low m3/sec 0.83 1.03

External Static pressure High Pa 221.0 270.0low Pa 132.0 147.0

Dimensions Height x Width x Depth mm 470 x 1380 x 1100Weight kg 137 137Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps 6.5 7.2Fuse Rating amps 13

Sound level Sound Pressure High dBA 48.0 48.0low dBA 45.0 45.0

Sound Power dBA - -Piping Connections liquid inches 3/8 3/8

Gas inches 3/4 7/8

Trade Unit Price £2,550.00 £2,610.00

VRV® Fan Coil – High Static DuctedFXMQ-MA

Notes:i) For accessories please refer to pages 77 - 84

Indoor Units FXMQ125MF FXMQ200MF FXMQ250MFCapacity UK Total Cooling kW TBC TBC TBC

UK Sensible Cooling kW TBC TBC TBCUK Heating kW - - -UK Heating VRViii HR only kW - - -Nominal Cooling kW 14.00 22.40 28.00Nominal Heating kW 8.90 13.90 17.40

Air Flow Rate High m3/sec 0.30 0.47 0.58External Static Pressure High Pa 185.0 225.0 205.0Dimensions Height x Width x Depth mm 470 x 744 x 1100 470 x 1380 x 1100Weight kg 86 123 123Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps 1.52.63.0

Fuse Rating amps 5Sound level Sound Pressure High dBA 43.0 48.0 48.0

low dBA ---

Sound Power dBA - - -Piping Connections liquid inches 3/8 3/8 3/8

Gas inches 5/8 3/4 7/8

Trade Unit Price £1,906.00 £3,149.00 £3,220.00

VRV® Fan Coil – Fresh Air Processing DuctedFXMQ-MF

Notes:i) Please contact your local sales office for guidance on installing this unitii) For accessories please refer to pages 77 - 84

Page 52: Daikin AC Price List 2013

Integrated Solutions

VRV®

50

Indoor Units FXaQ15P FXaQ20P FXaQ25P FXaQ32P FXaQ40P FXaQ50P FXaQ63PCapacity UK Total Cooling kW TBA 1.80 2.30 2.90 3.60 4.50 5.70

UK Sensible Cooling kW TBA 1.70 1.93 2.33 3.17 3.53 4.43UK Heating kW 1.45 1.91 2.44 3.05 3.81 4.80 6.10UK Heating VRViii HR only kW 1.56 2.05 2.62 3.28 4.10 5.16 6.56Nominal Cooling kW 1.70 2.20 2.80 3.60 4.50 5.60 7.10Nominal Heating kW 1.90 2.50 3.20 4.00 5.00 6.30 8.00

Air Flow Rate High m3/sec 0.12 0.13 0.13 0.15 0.20 0.25 0.32low m3/sec 0.08 0.08 0.08 0.09 0.15 0.20 0.23

Dimensions Height x Width x Depth mm 290 x 795 x 238 290 x 1050 x 238Weight kg 11 11 11 11 14 14 14Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps 0 0.2 0.3 0.3 0.3 0.4 0.5Fuse Rating amps 5

Sound level Sound Pressure High dBA 33 35.0 36.0 37.0 39.0 42.0 46.0low dBA 29 29.0 29.0 29.0 34.0 36.0 39.0

Sound Power dBA - - - - - - -Piping Connections liquid inches 1/4 1/4 1/4 1/4 1/4 1/4 3/8

Gas inches 1/2 1/2 1/2 1/2 1/2 1/2 5/8

Trade Unit Price £430.00 £443.00 £455.00 £460.00 £472.00 £497.00 £548.00

VRV® Fan Coil – Wall MountedFXAQ-P

Notes:i) For accessories please refer to pages 77 - 84

Indoor Units FXLQ20P FXLQ25P FXLQ32P FXLQ40P FXLQ50P FXLQ63PCapacity UK Total Cooling kW 1.80 2.30 2.90 3.60 4.50 5.70

UK Sensible Cooling kW 1.43 1.73 2.17 2.63 3.27 4.03UK Heating kW 1.91 2.44 3.05 3.81 4.80 6.10UK Heating VRViii HR only kW 2.05 2.62 3.28 4.10 5.16 6.56Nominal Cooling kW 2.20 2.80 3.60 4.50 5.60 7.10Nominal Heating kW 2.50 3.20 4.00 5.00 6.30 8.00

Air Flow Rate High m3/sec 0.12 0.12 0.13 0.18 0.23 0.27low m3/sec 0.10 0.10 0.10 0.14 0.18 0.20

Dimensions Height x Width x Depth mm 600 x 1000 x 232 600 x 1140 x 232 600 x 1420 x 232Weight kg 27 27 32 32 38 38Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps 0.2 0.2 0.5 0.5 0.5 0.5Fuse Rating amps 5

Sound level Sound Pressure High dBA 35.0 35.0 35.0 38.0 39.0 40.0low dBA 32.0 32.0 32.0 33.0 34.0 35.0

Sound Power dBA - - - - - -Piping Connections liquid inches 1/4 1/4 1/4 1/4 1/4 3/8

Gas inches 1/2 1/2 1/2 1/2 1/2 5/8

Trade Unit Price £681.00 £692.00 £706.00 £731.00 £739.00 £783.00

VRV® Fan Coil – Floor Mounted CasedFXLQ-P

Notes:i) For accessories please refer to pages 77 - 84

Page 53: Daikin AC Price List 2013

Price List 2013 51

VRV®

Indoor Units FXNQ20P FXNQ25P FXNQ32P FXNQ40P FXNQ50P FXNQ63PCapacity UK Total Cooling kW 1.80 2.30 2.90 3.60 4.50 5.70

UK Sensible Cooling kW 1.50 1.80 2.20 2.70 3.40 4.20UK Heating kW 1.91 2.44 3.05 3.81 4.80 6.10UK Heating VRViii HR only kW 2.05 2.62 3.28 4.10 5.16 6.56Nominal Cooling kW 2.20 2.80 3.60 4.50 5.60 7.10Nominal Heating kW 2.50 3.20 4.00 5.00 6.30 8.00

Air Flow Rate High m3/sec 0.12 0.12 0.13 0.18 0.23 0.27low m3/sec 0.10 0.10 0.10 0.14 0.18 0.20

Dimensions Height x Width x Depth mm 610 x 930 x 220 610 x 1070 x 220 610 x 1350 x 220Weight kg 19 19 23 23 27 27Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps 0.2 0.2 0.5 0.5 0.5 0.5Fuse Rating amps 5

Sound level Sound Pressure High dBA 35.0 35.0 35.0 38.0 39.0 40.0low dBA 32.0 32.0 32.0 33.0 34.0 35.0

Sound Power dBA - - - - - -Piping Connections liquid inches 1/4 1/4 1/4 1/4 1/4 3/8

Gas inches 1/2 1/2 1/2 1/2 1/2 5/8

Trade Unit Price £606.00 £616.00 £628.00 £651.00 £657.00 £698.00

VRV® Fan Coil – Floor Mounted ChassisFXNQ-P

VRV® Fan Coil – Low Level Wall Mounted Chassis (Medium Static) UK.FXDQ (Available from Summer 2013)

Notes:i) For accessories please refer to pages 77 - 84

Notes:i) For accessories please refer to pages 77 - 84

Indoor Units UK.FXDQ15a UK.FXDQ20a UK.FXDQ25a UK.FXDQ32a UK.FXDQ40a UK.FXDQ50a UK.FXDQ63aCapacity UK Total Cooling kW 1.40 1.80 2.30 2.90 3.60 4.50 5.70

UK Sensible Cooling kW 1.30 1.60 1.90 2.20 2.80 3.50 4.30UK Heating kW 1.30 1.91 2.44 3.05 3.81 4.80 6.10UK Heating VRViii HR only kW 1.39 2.05 2.62 3.28 4.10 5.16 6.56Nominal Cooling kW 1.70 2.20 2.80 3.60 4.50 5.60 7.10Nominal Heating kW 1.70 2.50 3.20 4.00 5.00 6.30 8.00

Air Flow Rate High m3/sec 0.13 0.13 0.13 0.13 0.18 0.21 0.28Nom m3/sec 0.12 0.12 0.12 0.12 0.16 0.18 0.24low m3/sec 0.11 0.11 0.11 0.11 0.14 0.17 0.22

External Static Pressure High Pa 30.0 30.0 30.0 30.0 44.0 44.0 44.0low Pa 10.0 10.0 10.0 10.0 15.0 15.0 15.0

Dimensions Height mm 620 x 700 x 200 620 x 950 x 200 620 x 1150 x 200Weight kg 22 22 22 22 26 26 29Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps 0.3 0.3 0.3 0.3 0.4 0.4 0.5Fuse Rating amps 5

Sound level Sound Pressure Hi Hi dBA 32.0 33.0 33.0 33.0 34.0 35.0 36.0High dBA 31.0 31.0 31.0 31.0 32.0 33.0 34.0low dBA 29.0 29.0 29.0 29.0 28.0 29.0 30.0

Sound Power dBA - - - - - - -Piping Connections liquid inches 1/4 1/4 1/4 1/4 1/4 1/4 3/8

Gas inches 1/2 1/2 1/2 1/2 1/2 1/2 5/8

Trade Unit Price £777.00 £794.00 £811.00 £819.00 £857.00 £883.00 £903.00

Page 54: Daikin AC Price List 2013

Integrated Solutions

VRV®

52

Small Air Curtains:Free Hanging, Cassette and Recessed

F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air outlet

accessory Ref Description Trade PriceBRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock £74.00 KRCS01-1 Remote room mounted temperature sensor £45.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV Poa

Accessories:i) Biddle Remote Controller and Connection

cable included for Fan Speed Control

ii) if RTD-20 Connected in Air Curtain mode the Biddle Remote Controller is NoT connected as Fan speed is Managed by RTD-20

iii) Code “BC” is for white finish. Aluminium finish “SC”available on request

Notes:

F = Free Hanging model C = Cassette model R = Recessed model

Biddle air curtains are the ideal solution for retailers and consultants to combat the issue of climate separation across their outlet or office doorway. Using a combination of rectifier technology, air velocity and temperature control they deliver greater comfort to staff and customers alike, all year round, in all weathers.

InconjunctionwithBiddle,DaikinVRV®IIIheatrecoveryaircurtain solution combines the benefits of the Biddle air curtain technologywiththebenefitsofDaikinVRV®IIIwithheatrecovery.

• Provides virtually free air curtain heating via recovered heat from indoor units in cooling mode

• Connection to the high COP heat recovery system enables COP’s of up to 4.36

• Short payback times – less than 3 years

• Air curtain rectifier technology – deeply penetrating airstream

• Constant air velocity technology – all year round efficiency

• European patent

• 1.0 to 2.5 metre door widths

• Door heights of 2.2 to 3.8 metres

• Choice of colour RAL9010:White or RAL9006:Grey

Easy and fast installation of these systems not only reduces costs but makes expensive water systems, boilers and gas connections redundant.IntegratingaBiddleaircurtainwithDaikinVRV®alsoeliminates the need to install multiple outdoor units thereby reducing installation time and costs further. This combination enables Daikin to offer its customers the ultimate environmentally conscious TOTAL SOLUTION PACKAGE comprising cooling, heating, outdoor-indoor climate separation and fresh air ventilation.

Air Curtains for VRV®III Heat Recovery

BIDDLe sTaNDaRD aIR cURTaIN - sMaLL cYVs100DK80*Bc cYVs150DK80*Bc cYVs200DK100*Bc cYVs250DK140*Bc* = F * = c * = R * = F * = c * = R * = F * = c * = R * = F * = c * = R

Heating Capacity speed 3 kW 7.40 9.00 11.60 16.20Delta T inlet = room temperature speed 3 k 15 15 15 16Power input (50Hz) Fan only / Heating kW 0.23 / 0.23 0.35 / 0.35 0.46 / 0.46 0.58 / 0.58Maximum Door Width m 1.00 1.50 2.00 2.50Mounting Height *2 Max / Min m 2.7/2.0 2.7/2.0 2.7/2.0 2.7/2.0Dimensions Height mm 270 270 270 270 270 270 270 270 270 270 270 270

Width mm 1,000 1,000 1,048 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548Depth mm 590 821 561 590 821 561 590 821 561 590 821 561

Weight kg 56 59 61 66 83 88 83 102 108 107 129 137Casing Colour white RAl9010 white RAl9010 white RAl9010 white RAl9010Minimum requiring ceiling void mm 420 420 420 420Fan - Air Flow Rate Heating speed 3 m3/sec 0.323 0.485 0.647 0.808Sound Pressure Heating speed 3 dBA 47 49 50 51Refrigerant Type R-410A R-410A R-410A R-410APiping Connections liquid (oD) / Gas mm 9.52/16.0 9.52/16.0 9.52/16.0 9.52/19.0Power Supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50 1~/230/50

Trade Unit Price £3,046.00 £3,009.00 £3,137.00 £3,880.00 £3,843.00 £4,065.00 £4,689.00 £4,653.00 £5,027.00 £5,232.00 £5,195.00 £5,605.00

Page 55: Daikin AC Price List 2013

Price List 2013 53

VRV®

Medium Air Curtains:Free Hanging, Cassette and Recessed

F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air outlet

accessory Ref Description Trade PriceBRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock £74.00 KRCS01-1 Remote room mounted temperature sensor £45.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV Poa

Accessories:i) Biddle Remote Controller and connection

cable included for Fan Speed Control

ii) if RTD-20 Connected in Air Curtain mode the Biddle Remote Controller is NoT connected as Fan speed is managed by RTD-20

iii) Code “BC” is for white finish. Aluminium finish “SC”available on request

Notes:

F = Free Hanging model C = Cassette model R = Recessed model

Large Air Curtains:Free Hanging, Cassette and Recessed

F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air outlet

accessory Ref Description Trade PriceBRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock £74.00 KRCS01-1 Remote room mounted temperature sensor £45.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV Poa

Accessories:i) Biddle Remote Controller and connection

cable included for Fan Speed Control

ii) if RTD-20 Connected in Air Curtain mode the Biddle Remote Controller is NoT connected as Fan speed is managed by RTD-20

iii) Code “BC” is for white finish. Aluminium finish “SC”available on request

Notes:

F = Free Hanging model C = Cassette model R = Recessed model

BIDDLe sTaNDaRD aIR cURTaIN - MeDIUM cYVM100DK80*Bc cYVM150DK80*Bc cYVM200DK100*Bc cYVM250DK140*Bc* = F * = c * = R * = F * = c * = R * = F * = c * = R * = F * = c * = R

Heating Capacity speed 3 kW 9.20 11.00 13.40 19.90Delta T inlet = room temperature speed 3 k 17 14 13 15Power input (50Hz) Fan only / Heating kW 0.37 / 0.37 0.56 / 0.56 0.75 / 0.75 0.94 / 0.94Maximum Door Width m 1.00 1.50 2.00 2.50Mounting Height *2 Max / Min m 3.2/2.3 3.2/2.3 3.2/2.3 3.2/2.3Dimensions Height mm 270 270 270 270 270 270 270 270 270 270 270 270

Width mm 1,000 1,000 1,048 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548Depth mm 590 821 561 590 821 561 590 821 561 590 821 561

Weight kg 57 68 66 73 88 93 94 111 117 108 136 144Casing Colour white RAl9010 white RAl9010 white RAl9010 white RAl9010Minimum requiring ceiling void mm 420 420 420 420Fan - Air Flow Rate Heating speed 3 m3/sec 0.446 0.669 0.892 1.115Sound Pressure Heating speed 3 dBA 50 51 53 54Refrigerant Type R-410A R-410A R-410A R-410APiping Connections liquid (oD) / Gas mm 9.52/16.0 9.52/16.0 9.52/16.0 9.52/19.0Power Supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50 1~/230/50

Trade Unit Price £3,484.00 £3,447.00 £3,576.00 £4,464.00 £4,427.00 £4,623.00 £5,531.00 £5,494.00 £5,867.00 £6,295.00 £6,258.00 £6,661.00

BIDDLe sTaNDaRD aIR cURTaIN - LaRGe cYVL100DK125*Bc cYVL150DK200*Bc cYVL200DK250*Bc cYVL250DK250*Bc* = F * = c * = R * = F * = c * = R * = F * = c * = R * = F * = c * = R

Heating Capacity speed 3 kW 15.60 23.30 29.40 31.10Delta T inlet = room temperature speed 3 k 15 15 14 12Power input (50Hz) Fan only / Heating kW 0.75 / 0.75 1.13 / 1.13 1.50 / 1.50 1.88 / 1.88Maximum Door Width m 1.00 1.50 2.00 2.50Mounting Height *2 Max / Min m 3.7/2.5 3.7/2.5 3.7/2.5 3.7/2.5Dimensions Height mm 370 370 370 370 370 370 370 370 370 370 370 370

Width mm 1,000 1,000 1,048 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548Depth mm 774 1105 745 774 1105 745 774 1105 745 774 1105 745

Weight kg 76 81 83 100 118 141 126 151 155 157 190 196Casing Colour white RAl9010 white RAl9010 white RAl9010 white RAl9010Minimum requiring ceiling void mm 520 520 520 520Fan - Air Flow Rate Heating speed 3 m3/sec 0.861 1.292 1.722 2.153Sound Pressure Heating speed 3 dBA 53 54 56 57Refrigerant Type R-410A R-410A R-410A R-410APiping Connections liquid (oD) / Gas mm 9.52/16.0 9.52/19.0 9.52/22.0 9.52/22.0Power Supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50 1~/230/50

Trade Unit Price £4,439.00 £4,393.00 £4,528.00 £5,906.00 £5,860.00 £6,043.00 £7,272.00 £7,226.00 £7,589.00 £8,446.00 £8,400.00 £8,846.00

Page 56: Daikin AC Price List 2013

Integrated Solutions

VRV®

54

Total solution heat recoveryTodate,theprimaryoperationoftheVRV®heatrecoverysystemhas been to extract heat from areas of a building being cooled and redistribute and recycle this heat for re-use in other parts of the building with a heating requirement, often as a result of building orientation and diversity.

However, if more heat is extracted than can be effectively re-used this surplus heat is generally dissipated to the atmosphereattheVRV®outdoorunitandsubsequentlytherecovered energy is wasted.

Available for either high temperature or low temperature water.

• High temperature cascade Hydrobox suitable for heating and hot water applications with leaving temperatures up between 25and80°C.ForconnectiontoHeatRecoverysystemsREYAQ.For this system the Hydrobox is complete with expansion vessels, circulating pumps and controls built in as standard

• For applications requiring chilled water, other capacity sizes or different installation configurations, please contact your local sales office for advice

• Possibility to integrate high temperature Hydrobox with solar collectorsfordomestichotwaterstorage.(details&pricesavailable on request)

HT Hot Water Module for VRV®III Heat Recovery

Ideally positioned for the commercial sector, Daikin UK now offers a choice of energy efficient domestic hot water and heating solutions for w.c. facilities, kitchens and staff break out areas. TheVRV®IIIhotwatermoduleoperateswiththeVRV®IIIheatrecoverysystemtoprovideanenergyefficient means of producing hot water from recovered or recycled heat.

VRV heat recovery with connection to heating only

hydrobox(REYAQ10-16P)

BS-Box

BS-Box

Heating only hydrobox for VRV

Domestic hot water

Low temp. radiator

Air handling unit

Under floor heating

VRV indoor units

25°C - 35°C

45°C - 75°C

25°C - 75°C

45°C - 75°C

Liquid pipe

F1, F2 communication

Gas pipe

Hot water

Discharge gas pipe

Thermal store *

* Please refer to Daikin heating price list for this unit

Page 57: Daikin AC Price List 2013

Price List 2013 55

VRV®

INDooR UNIT (hYDRo BoX) hXhD125aFunction Heating & Hot waterHeating Capacity kW 14Capacity index 125Dimensions HxWxD mm 705x600x695 Empty Weight kg 92leaving Water Temperature Range heating °C 25~80 Drain valve Yes Water Pump Yes Expansion Vessel Yes Material Precoated sheet metalColour Metalic GreyHydrobox Power Supply 230V Single Phase (20A)Refrigerant Pipe Sizes 12.7mm Gas 9.52mm GasWater Side Pipe Sizes 1”Sound Pressure level dBA 42Refrigerant R134a Cascade

Trade Unit Price hydro Box £2,660.00

accessoRY FoR hYDRo BoX Trade Unit PriceEKRP1HBA Digitai/o PCB £104.00EKRP1AHT Demand PCB £104.00EKRUAHTB Remote user interface ( one included as standard - intregated with Hydrobox) £157.00EKRTWA Wired Room thermostat ( Requires EKRP1AHTA) £99.00EKRTR Wireless Room thermostat ( Requires EKRP1AHTA) £194.00EKRTETS Floor temperature sensor for use with EKRTR ( Requires EKRP1AHTA) £14.00

HT Hot Water ModuleForConnectionOnlytoREYAQOutdoorSeriesVRV®IIIHeatRecovery

Notes:i) Hydroboxes are connectable to the

following outdoor series only: Air Cooled Heat Recovery REYAQ-P (see page 66)

ii) Hydroboxes are inclusive of integral expansion vessel, and pump

DoMesTIc UNVeNTeD hoT waTeR TaNK eKhTsU200ac eKhTsU260acUnvented System (includes EKUHWHT unvented Kit as shown below)

Water Volume l 200 260Max Water Temperature °C 75Height mm 1335 1610Width mm 600 600Depth mm 695 695Empty Weight kg 81 89Colour Metallic greyMaterial inside Tank Stainless SteelMaterial outside Casing Precoated sheet metalPiping Connections (Diameter)

Water inlet H/E inch 3/4 “Water outlet H/E inch 3/4 “Cold Water in inch 3/4 “Hot water out inch 3/4 “

Trade Unit Price £1,113.00 £1,261.00

accessoRIes FoR UNVeNTeD sYsTeMs Trade Unit PriceeKUhwhT includes: Combined Pressure Reducing Valve, Non Return Valve, Strainer, Expansion Relief Valve,

Expansion Vessel, Tundish Included with eKhTsU*ac

eKFMahTB option for stand alone tank (ie not mounted on top of hydrobox) £277.00

HT Water Tank

Notes:i) Hydroboxes are connectable to the

following outdoor series only: Air Cooled Heat Recovery REYAQ-P (see page 66)

ii) Hydroboxes are inclusive of integral expansion vessel and pump

Page 58: Daikin AC Price List 2013

Integrated Solutions

VRV®

56

VRV®

Low Temperature HydroboxHXY-A

Liquid pipe

F1, F2 communication

Gas pipe

Hot/cold water

Low temp. radiator

Air handling unit

Under floor heating

VRV IV heat pump

VRV indoor units

Indoor Units hXY080a hXY125aCooling capacity Nom. kW 8 12.5Heating capacity Nom. kW 9 14Casing Colour White

Material Precoated sheet metalDimensions Unit Height x Width x Depth mm 890 x 480 x 344Weight Unit kg 44Sound pressure level Nom. dBA -operation range Heating Ambient Min.~Max. °C -20~24

Water side Min.~Max. °C 25~45Cooling Ambient Min.~Max. °C ~-

Water side Min.~Max. °C -~-Refrigerant Type -Refrigerant circuit Gas side diameter mm 15.9

liquid side diameter mm 9.5Water circuit Piping connections diameter inch G 1”1/4 (female)Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240Recommended fuses A

Trade Unit Price £1,178.00 £1,432.00

The low temperature Hydrobox offers air-to-water connection to VRV IV Heat Pump and is ideal for applications such as under floor heating, air handling units and low temperature radiators.

Page 59: Daikin AC Price List 2013

Price List 2013 57

VRV®

outdoor Units RXYsQ4P8V1 RXYsQ5P8V1 RXYsQ6P8V1 RXYsQ4P8Y1 RXYsQ5P8Y1 RXYsQ6P8Y1Capacity Nominal Cooling kW 12.60 14.00 15.50 12.60 14.00 15.50

Nominal Heating kW 14.20 16.00 18.00 14.20 16.00 18.00Dimensions Height x Width x Depth mm 1345 x 900 x 320 1345 x 900 x 320 1345 x 900 x 320 1345 x 900 x 320 1345 x 900 x 320 1345 x 900 x 320Weight kg 120 120 120 120 120 120Air Flow Rate m3/sec 1.77 1.77 1.77 1.77 1.77 1.77Electrical Details Power Supply Phase 1ph 3ph

Hz 50 50V 230 400

Running Current amps 15.9 20.2 22.2 5.3 6.8 7.8Starting Current amps 4 4 4 4 4 4Fuse Rating amps 32 32 32 16 16 16

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 4.0Additional Charge kg data book

Sound Pressure dBA 50 51 53 50 51 53Sound Power dBA 66 67 69 66 67 69Piping limits Maximum length m 300

Maximum Vertical Rise m data bookPiping Connections liquid inches 3/8 3/8 3/8 3/8 3/8 3/8

Gas inches 5/8 5/8 3/4 5/8 5/8 3/4Capacity index limit 50~130 62.5~162.5 70~182 50~130 62.5~162.5 70~182Maximum Number of Connected indoor Units 8 10 12 8 10 12

Trade condensing Unit Price £2,681.00 £3,014.00 £3,364.00 £2,681.00 £3,472.00 £3,734.00

VRV®III Condensing Units – Heat Pump Inverter MiniRXYSQ

Notes:The VRV® III-S is highly space saving, featuring a slimmer and more compact outdoor unit compared to conventional models. Supplied in three sizes of 4 HP (11.2 kW), 5HP (14 kW) and 6HP (15.5 kW) with a single or three phase power supply. Compatible with the full range of existing VRV® fan coil units providing a choice of 12 types and 72 models. installation is improved by the completely new casing design of the outdoor unit with a footprint of just 320mm deep by 900mm wide, which reduces installation space requirements by over 40% (14.0kW model) and enables it to fit easily onto balconies and narrow ledges. Maximum piping length is 150m, total piping length is 300m and maximum vertical differential between outdoor and indoor units is 50m (40m when outdoor is below indoor units). The Daikin ‘Super Wiring’ system allows shared use of the wiring between indoor and outdoor units and the centralised remote control, the non polarity of the system obviating incorrect connection and reducing installation time.

Smooth air inlet bell mouth and aero spiral fanThese features assist in significantly reducing noise. Guides are added to the bell mouth intake to reduce turbulence in the air flow generated by fan suction. The aero spiral fan features fan blades with bent blade edges, further reducing turbulence.

Super aero grilleThe spiral shaped ribs are aligned with the direction

of discharge flow in order to minimise turbulence and

reduce noise.

e-Bridge circuitPrevents accumulation of liquid refrigerant in the

condenser. This results in more efficient use of the

condenser surface under all conditions and leads in turn

to better energy efficiency. Increased evaporative capacity

stems from the newly developed refrigeration circuit, the

SCe-bridge circuit, which adds super cooling prior to the

expansion cycle. By adopting this circuit, the COPs in both

cooling and heating have been drastically improved.

Advanced technologies

1

2

3

Conventional New

Escaping edges are sucked in by the bent blade edges, reducing overall turbulence.

Aero spiral fan blade tips

1

2

3

Page 60: Daikin AC Price List 2013

Integrated Solutions

VRV®

58

Heat Pump VRV®IVRYYQ-TReplacesRXYQ-P9/RXYHQ-P9/RXYRQ-P9/RXHQ-P

outdoor Units RYYQ8T RYYQ10T RYYQ12T RYYQ14T RYYQ16T RYYQ18T RYYQ20TCapacity Nominal Cooling kW 22.40 28.00 33.50 40.00 45.00 50.00 56.00

Nominal Heating kW 25.00 31.50 37.50 45.00 50.00 56.00 63.00EER 4.30 3.84 3.73 3.64 3.46 3.40 3.03ESEER 7.53* 7.2* 6.96* 6.83* 6.5* 6.38* 5.67*CoP 4.55 4.27 4.12 4.02 3.91 3.89 3.71Dimensions Height x Width x Depth mm 1685 x 930 x 765 1685 x 930 x 765 1685 x 930 x 765 1685 x 1240 x 765 1685 x 1240 x 765 1685 x 1240 x 765 1685 x 1240 x 765Weight kg 261 268 268 364 364 398 398Air Flow Rate m3/sec 2.70 2.92 3.08 3.72 4.33 4.18 4.35External Static Pressure High Pa 78 78 78 78 78 78 78Electrical Details Power Supply Phase /Hz / V 3ph / 50 Hz / 380~415V

Running Current amps 7.2 11.3 12.7 15.4 18.0 20.8 26.9Starting Current amps databookFuse Rating amps 20 25 32 32 40 40 50

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 5.9 6.0 6.3 10.3 10.4 11.7 11.8Additional Charge kg data book

Sound Pressure dBA 58 58 61 61 64 65 66Sound Power dBA 78 79 81 81 86 86 88Piping limits Maximum length m 165 165 165 165 165 165 165

Maximum Vertical Rise m data bookPiping Connections liquid inches 3/8 3/8 1/2 1/2 1/2 5/8 5/8

Gas inches 3/4 7/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8Capacity index limit 100~260 125~325 150~390 175~455 200~520 225~585 250~650Maximum Number of Connected indoor Units 64 64 64 64 64 64 64

Trade condensing Unit Price £4,453.00 £4,866.00 £5,958.00 £6,951.00 £8,023.00 £8,937.00 £9,830.70

* The AUToMATiC ESEER value corresponds with normal VRV iV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

VRV®IV Heat Pump with Continuous HeatingRYYQ-T(upto20HP)

3 revolutionary features:

Variable refrigerant temperature Customise your VRV® for best Seasonal Efficiency and comfort:

• Revolutionary variable refrigerant temperature control automatically adapts the system to individual building and climate requirements for greater efficiency and comfort

• Continuously adjusts refrigerant temperature to the actual temperature and capacity required

• Default mode optimised by Daikin for UK conditions with maximum efficiency and comfort

• Delivers annual cost savings of up to 25%

continuous heating during defrost The new standard in heating comfort:

•UniquecontinuousheatingtechnologymakesVRV®IVHeatPump the best alternative to traditional heating systems

• Delivers uninterrupted heat, even during the defrost cycle

• Maintains comfortable indoor climate at all times

VRV® configuratorAdvanced software for simplified commissioning, servicing, configuration and customisation:

• Simplified commissioning: graphical interface to configure, commission and upload system settings

• Simplified servicing: additional 7-segment indicator for easy and quick access to basic functions and error read out

• Manage systems over multiple sites

Page 61: Daikin AC Price List 2013

Price List 2013 59

VRV®

outdoor Units RYYQ22T RYYQ24TRYMQ10T RYMQ12T RYMQ8T RYMQ16T

Capacity Nominal Cooling kW 61.50 67.40Nominal Heating kW 69.00 75.00

EER 3.77 3.70ESEER 7.07* 6.81*CoP 4.18 4.10Dimensions Height x Width x Depth mm 1685 x 930 x 765 1685 x 930 x 765 1685 x 930 x 765 1685 x 1240 x 765Weight kg 195 195 188 309Air Flow Rate m3/sec 2.92 3.08 2.70 4.33External Static Pressure High Pa 78 78 78 78Electrical Details Power Supply Phase /Hz / V 3ph / 50 Hz / 380~415V

Running Current amps 10.2 12.7 7.2 18.0Starting Current amps databookFuse Rating amps 25 32 20 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 6.0 6.3 5.9 10.4Additional Charge kg databook

Sound Pressure dBA 58 61 58 64Sound Power dBA 79 81 78 86Piping limits Maximum length m 165 165

Maximum Vertical Rise m databookPiping Connections liquid inches 5/8 5/8

Gas inches 1 1/8 1 3/8Capacity index limit 275~715 300~780Maximum Number of Connected indoor Units 64 64

Trade condensing Unit Price £10,824.00 £12,476.00

* The AUToMATiC ESEER value corresponds with normal VRV iV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

outdoor Units RYYQ26T RYYQ28T RYYQ30T RYYQ32T RYYQ34TRYMQ12T RYMQ14T RYMQ12T RYMQ16T RYMQ12T RYMQ18T RYMQ16T RYMQ16T RYMQ16T RYMQ18T

Capacity Nominal Cooling kW 73.50 78.50 83.50 90.00 95.00Nominal Heating kW 82.50 87.50 93.50 100.00 106.00

EER 3.68 3.57 3.52 3.46 3.43ESEER 6.89* 6.69* 6.6* 6.5* 6.44*CoP 4.06 4.00 3.98 3.91 3.90Dimensions Height mm 1685 1685 1685 1685 1685 1685 1685 1685 1685 1685

Width mm 930 1240 930 1240 930 1240 1240 1240 1240 1240Depth mm 765 765 765 765 765 765 765 765 765 765

Weight kg 195 309 195 309 195 319 309 309 309 319Air Flow Rate m3/sec 3.08 3.72 3.08 4.33 3.08 4.18 4.33 4.33 4.33 4.18External Static Pressure High Pa 78 78 78 78 78 78 78 78 78 78Electrical Details Power Supply Phase /Hz / V 3ph / 50 Hz / 380~415V

Running Current amps 12.7 15.4 12.7 18.0 12.7 20.8 18.0 18.0 18.0 20.8Starting Current amps databookFuse Rating amps 32 32 32 40 32 40 40 40 40 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 6.3 10.3 6.3 10.4 6.3 11.7 10.4 10.4 10.4 11.7Additional Charge kg data book

Sound Pressure dBA 61 61 61 64 61 65 64 64 64 65Sound Power dBA 81 81 81 86 81 86 86 86 86 86Piping limits Maximum length m 165

Maximum Vertical Rise m data bookPiping Connections liquid inches 3/4 3/4 3/4 3/4 3/4

Gas inches 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8Capacity index limit 325~845 350~910 375~975 400~1040 425~1105Maximum Number of Connected indoor Units 64 64 64 64 64

Trade condensing Unit Price £12,909.00 £13,981.00 £14,895.00 £16,046.00 £16,960.00

* The AUToMATiC ESEER value corresponds with normal VRV iV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

VRV®IV Heat Pump with Continuous HeatingRYYQ-T(22to24HP)

VRV®IV Heat Pump with Continuous HeatingRYYQ-T(26to34HP)

Page 62: Daikin AC Price List 2013

Integrated Solutions

VRV®

60

outdoor Units RYYQ36T RYYQ38T RYYQ40T RYYQ42TRYMQ16T RYMQ20T RYMQ8T RYMQ10T RYMQ20T RYMQ10T RYMQ12T RYMQ18T RYMQ10T RYMQ16T RYMQ16T

Capacity Nominal Cooling kW 101.00 106.00 112.00 118.00Nominal Heating kW 113.00 120.00 125.00 132.00

EER 3.21 3.42 3.61 3.54ESEER 6.02* 6.36* 6.74* 6.65*CoP 3.79 4.01 4.05 4.00Dimensions Height mm 1685 1685 1685 1685 1685 1685 1685 1685 1685 1685 1685

Width mm 1240 1240 930 930 1240 930 930 1240 930 1240 1240Depth mm 765 765 765 765 765 765 765 765 765 765 765

Weight kg 309 319 188 195 319 195 195 319 195 309 309Air Flow Rate m3/sec 4.33 4.35 2.70 2.92 4.35 2.92 3.08 4.18 2.92 4.33 4.33External Static Pressure High Pa 78 78 78 78 78 78 78 78 78 78 78Electrical Details Power Supply Phase /Hz / V 3ph / 50 Hz / 380~415V

Running Current amps 18.0 26.9 7.2 10.2 26.9 10.2 12.7 20.8 10.2 18.0 18.0Starting Current amps databook databook databook databookFuse Rating amps 40 50 20 25 50 25 32 40 25 40 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 10.4 11.8 5.9 6.0 11.8 6.0 6.3 11.7 6.0 10.4 10.4Additional Charge kg data book

Sound Pressure dBA 64 66 58 58 66 58 61 65 58 64 64Sound Power dBA 86 88 78 79 88 79 81 86 79 86 86Piping limits Maximum length m 165

Maximum Vertical Rise m data bookPiping Connections liquid inches 3/4 3/4 3/4 3/4

Gas inches 1 5/8 1 5/8 1 5/8 1 5/8Capacity index limit 450~1170 475~1235 500~1300 525~1365Maximum Number of Connected indoor Units 64 64 64 64

Trade condensing Unit Price £17,853.70 £19,149.70 £19,761.00 £20,912.00

* The AUToMATiC ESEER value corresponds with normal VRV iV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

outdoor Units RYYQ44T RYYQ46T RYYQ48TRYMQ12T RYMQ16T RYMQ16T RYMQ14T RYMQ16T RYMQ16T RYMQ16T RYMQ16T RYMQ16T

Capacity Nominal Cooling kW 124.00 130.00 135.00Nominal Heating kW 138.00 145.00 150.00

EER 3.54 3.51 3.46ESEER 6.62* 6.6* 6.5*CoP 3.98 3.94 3.91Dimensions Height mm 1685 1685 1685 1685 1685 1685 1685 1685 1685

Width mm 930 1240 1240 1240 1240 1240 1240 1240 1240Depth mm 765 765 765 765 765 765 765 765 765

Weight kg 195 309 309 309 309 309 309 309 309Air Flow Rate m3/sec 3.08 4.33 4.33 3.72 4.33 4.33 4.33 4.33 4.33External Static Pressure High Pa 78 78 78 78 78 78 78 78 78Electrical Details Power Supply Phase /Hz / V 3ph / 50 Hz / 380~415V

Running Current amps 12.7 18.0 18.0 15.4 18.0 18.0 18.0 18.0 18.0Starting Current amps databook databook databookFuse Rating amps 32 40 40 32 40 40 40 40 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 6.3 10.4 10.4 10.3 10.4 10.4 10.4 10.4 10.4Additional Charge kg data book

Sound Pressure dBA 61 64 64 61 64 64 64 64 64Sound Power dBA 81 86 86 81 86 86 86 86 86Piping limits Maximum length m 165

Maximum Vertical Rise m data bookPiping Connections liquid inches 3/4 3/4 3/4

Gas inches 1 5/8 1 5/8 1 5/8Capacity index limit 550~1430 575~1495 600~1560Maximum Number of Connected indoor Units 64 64 64

Trade condensing Unit Price £22,004.00 £22,997.00 £24,069.00

* The AUToMATiC ESEER value corresponds with normal VRV iV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

VRV®IV Heat Pump with Continuous HeatingRYYQ-T(36to42HP)

VRV®IV Heat Pump with Continuous HeatingRYYQ-T(44to48HP)

Page 63: Daikin AC Price List 2013

Price List 2013 61

VRV®

outdoor Units RYYQ50T RYYQ52T RYYQ54TRYMQ16T RYMQ16T RYMQ18T RYMQ16T RYMQ18T RYMQ18T RYMQ18T RYMQ18T RYMQ18T

Capacity Nominal Cooling kW 140.00 145.00 150.00Nominal Heating kW 156.00 162.00 168.00

EER 3.44 3.42 3.40ESEER 6.46* 6.42* 6.38*CoP 3.90 3.89 3.89Dimensions Height mm 1685 1685 1685 1685 1685 1685 1685 1685 1685

Width mm 1240 1240 1240 1240 1240 1240 1240 1240 1240Depth mm 765 765 765 765 765 765 765 765 765

Weight kg 309 309 319 309 319 319 319 319 319Air Flow Rate m3/sec 4.33 4.33 4.18 4.33 4.18 4.18 4.18 4.18 4.18External Static Pressure High Pa 78 78 78 78 78 78 78 78 78Electrical Details Power Supply Phase 3ph / 50 Hz / 380~415V

Running Current amps 18.0 18.0 20.8 18.0 20.8 20.8 20.8 20.8 20.8Starting Current amps databook databook databookFuse Rating amps 40 40 40 40 40 40 40 40 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 10.4 10.4 11.7 10.4 11.7 11.7 11.7 11.7 11.7Additional Charge kg data book

Sound Pressure dBA 64 64 65 64 65 65 65 65 65Sound Power dBA 86 86 86 86 86 86 86 86 86Piping limits Maximum length m 165

Maximum Vertical Rise m data bookPiping Connections liquid inches 3/4 3/4 3/4

Gas inches 1 5/8 1 5/8 1 5/8Capacity index limit 625~1625 650~1690 675~1755Maximum Number of Connected indoor Units 64 64 64

Trade condensing Unit Price £24,983.00 £25,897.00 £26,811.00

* The AUToMATiC ESEER value corresponds with normal VRV iV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

VRV®IV Heat Pump with Continuous HeatingRYYQ-T(50to54HP)

Page 64: Daikin AC Price List 2013

Integrated Solutions

VRV®

62

outdoor Units ReYQ8P9 ReYQ10P8 ReYQ12P9 ReYQ14P8 ReYQ16P8Capacity Nominal Cooling kW 22.40 28.00 33.50 40.00 45.00

Nominal Heating kW 25.00 31.50 37.50 45.00 50.00Dimensions Height x Width x Depth mm 1680 x 1300 x 765 1680 x 1300 x 765 1680 x 1300 x 765 1680 x 1300 x 765 1680 x 1300 x 765Weight kg 331 331 331 339 339Air Flow Rate m3/sec 3.17 3.17 3.50 3.92 4.00Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 11.7 13.8 16.0 18.4 23.8Starting Current amps 74 74 75 4 4Fuse Rating amps 20 25 25 40 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 10.3 10.6 10.8 11.1 11.1Additional Charge kg data book

Sound Pressure dBA 58 58 60 62 63Piping limits Maximum length m 165

Maximum Vertical Rise m data bookPiping Connections - Systems

liquid inches 3/8 3/8 1/2 1/2 1/2Gas inches 3/4 7/8 1 1/8 1 1/8 1 1/8Discharge inches 5/8 3/4 3/4 7/8 7/8

Capacity index limit 100~260 125~325 150~390 175~455 200~520Maximum Number of Connected indoor Units 13 16 19 22 26

Trade condensing Unit Price £4,886.00 £5,368.00 £6,509.00 £7,674.00 £9,043.00

VRV®III Condensing Units – Heat RecoveryREYQ-P9–Compact(upto16HP)

outdoor Units ReYQ18P9 ReYQ20P9 ReYQ22P8 ReYQ24P8ReMQ8P9 ReMQ10P8 ReMQ8P9 ReMQ12P8 ReMQ10P8 ReMQ12P8 ReMQ12P8 ReMQ12P8

Capacity Nominal Cooling kW 50.40 55.90 61.50 67.00Nominal Heating kW 56.50 62.50 69.00 75.00

Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680Width mm 930 930 930 930 930 930 930 930Depth mm 765 765 765 765 765 765 765 765

Weight kg 204 254 204 254 254 254 254 254Air Flow Rate m3/sec 3.00 3.08 3.00 3.33 3.08 3.33 3.33 3.33Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 8.9 + 12.2 8.9 + 14.9 12.2 + 14.9 14.9 + 14.9Starting Current amps 78 79 88 88Fuse Rating amps 25 25 25 25 25 25 25 25

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 8.2 9.0 8.2 9.1 9.0 9.1 9.1 9.1Additional Charge kg data book

Sound Pressure dBA 58 58 58 60 58 60 60 60Piping limits Maximum length m 165

Maximum Vertical Rise m data bookPiping Connections - Systems

liquid inches 5/8 5/8 5/8 5/8Gas inches 1 1/8 1 1/8 1 1/8 1 3/8Discharge inches 7/8 1 1/8 1 1/8 1 1/8oil Equalising inches 3/4 3/4 3/4 3/4

Capacity index limit 225~585 250~650 275~715 300~780Maximum Number of Connected indoor Units 29 32 35 39

Trade condensing Unit Price £10,254.00 £11,395.00 £11,877.00 £13,018.00

VRV®III Condensing Units – Heat RecoveryREYQ-P9–Compact(18to24HP)

Page 65: Daikin AC Price List 2013

Price List 2013 63

VRV®

outdoor Units ReYQ26P8 ReYQ28P8 ReYQ30P8 ReYQ32P8ReMQ10P8 ReMQ16P8 ReMQ12P8 ReMQ16P8 ReMQ14P8 ReMQ16P8 ReMQ16P8 ReMQ16P8

Capacity Nominal Cooling kW 73.00 78.50 85.00 90.00Nominal Heating kW 81.50 87.50 95.00 100.00

Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680Width mm 930 1240 930 1240 1240 1240 1240 1240Depth mm 765 765 765 765 765 765 765 765

Weight kg 254 334 254 334 334 334 334 334Air Flow Rate m3/sec 3.08 3.83 3.33 3.83 3.83 3.83 3.83 3.83Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 12.2 + 22.5 14.9 + 22.5 19.6 + 22.5 22.5 + 22.5Starting Current amps 98 98 108 109Fuse Rating amps 25 40 25 40 40 40 40 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 9.0 11.7 9.1 11.7 11.7 11.7 11.7 11.7Additional Charge kg data book

Sound Pressure dBA 58 63 60 63 62 63 63 63Piping limits Maximum length m 165

Maximum Vertical Rise m data bookPiping Connections liquid inches 3/4 3/4 3/4 3/4

Gas inches 1 3/8 1 3/8 1 3/8 1 3/8Discharge inches 1 1/8 1 1/8 1 1/8 1 1/8oil Equalising inches 3/4 3/4 3/4 3/4

Capacity index limit 325~845 350~910 375~975 400~1040Maximum Number of Connected indoor Units 42 45 48 52

Trade condensing Unit Price £14,411.00 £15,552.00 £16,717.00 £18,086.00

VRV®III Condensing Units – Heat RecoveryREYQ-P9–Compact(26to32HP)

outdoor Units ReYQ34P9 ReYQ36P9 ReYQ38P8ReMQ8P9 ReMQ10P8 ReMQ16P8 ReMQ8P9 ReMQ12P8 ReMQ16P8 ReMQ10P8 ReMQ12P8 ReMQ16P8

Capacity Nominal Cooling kW 95.40 101.00 107.00Nominal Heating kW 107.00 113.00 119.00

Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680 1680Width mm 930 930 1240 930 930 1240 930 930 1240Depth mm 765 765 765 765 765 765 765 765 765

Weight kg 204 254 334 204 254 334 254 254 334Air Flow Rate m3/sec 3.00 3.08 3.83 3.00 3.33 3.83 3.08 3.33 3.83Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 8.9 + 12.2 + 22.5 8.9 + 14.9 + 22.5 12.2 + 14.9 + 22.5Starting Current amps 101 102 111Fuse Rating amps 25 25 40 25 25 40 25 25 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 8 9 12 8 9 12 9 9 12Additional Charge kg data book

Sound Pressure dBA 58 58 63 58 60 63 58 60 63Piping limits Maximum length m 165

Maximum Vertical Rise m data bookPiping Connections liquid inches 3/4 3/4 3/4

Gas inches 1 3/8 1 5/8 1 5/8Discharge inches 1 1/8 1 1/8 1 3/8oil Equalising inches 3/4 3/4 3/4

Capacity index limit 425~1105 450~1170 475~1235Maximum Number of Connected indoor Units 55 58 61

Trade condensing Unit Price £19,297.00 £20,438.00 £20,920.00

VRV®III Condensing Units – Heat RecoveryREYQ-P9–Compact(34to38HP)

Page 66: Daikin AC Price List 2013

Integrated Solutions

VRV®

64

outdoor Units ReYQ40P8 ReYQ42P8 ReYQ44P8ReMQ12P8 ReMQ12P8 ReMQ16P8 ReMQ10P8 ReMQ16P8 ReMQ16P8 ReMQ12P8 ReMQ16P8 ReMQ16P8

Capacity Nominal Cooling kW 112.00 118.00 124.00Nominal Heating kW 125.00 132.00 138.00

Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680 1680Width mm 930 930 1240 930 1240 1240 930 1240 1240Depth mm 765 765 765 765 765 765 765 765 765

Weight kg 254 254 334 254 334 334 254 334 334Air Flow Rate m3/sec 3.33 3.33 3.83 3.08 3.83 3.83 3.33 3.83 3.83Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 14.9 + 14.9 + 22.5 12.2 + 22.5 + 22.5 14.9 + 22.5 + 22.5Starting Current amps 111 122 122Fuse Rating amps 25 25 40 25 40 40 25 40 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 9 9 12 9 12 12 9 12 12Additional Charge kg data book

Sound Pressure dBA 60 60 63 58 63 63 60 63 63Piping limits Maximum length m 165

Maximum Vertical Rise m data bookPiping Connections liquid inches 3/4 3/4 3/4

Gas inches 1 5/8 1 5/8 1 5/8Discharge inches 1 3/8 1 3/8 1 3/8oil Equalising inches 3/4 3/4 3/4

Capacity index limit 500~1300 525~1365 550~1430Maximum Number of Connected indoor Units 64 64 64

Trade condensing Unit Price £22,061.00 £23,454.00 £24,595.00

VRV®III Condensing Units – Heat RecoveryREYQ-P9–Compact(40to44HP)

outdoor Units ReYQ46P8 ReYQ48P8ReMQ14P8 ReMQ16P8 ReMQ16P8 ReMQ16P8 ReMQ16P8 ReMQ16P8

Capacity Nominal Cooling kW 130.00 135.00Nominal Heating kW 145.00 150.00

Dimensions Height mm 1680 1680 1680 1680 1680 1680Width mm 1240 1240 1240 1240 1240 1240Depth mm 765 765 765 765 765 765

Weight kg 334 334 334 334 334 334Air Flow Rate m3/sec 3.83 3.83 3.83 3.83 3.83 3.83Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 19.6 + 22.5 + 22.5 22.5 + 22.5 + 22.5Starting Current amps 132 134Fuse Rating amps 40 40 40 40 40 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 12 12 12 12 12 12Additional Charge kg data book

Sound Pressure dBA 62 63 63 63 63 63Piping limits Maximum length m 165

Maximum Vertical Rise m data bookPiping Connections liquid inches 3/4 3/4

Gas inches 1 5/8 1 5/8Discharge inches 1 3/8 1 3/8oil Equalising inches 3/4 3/4

Capacity index limit 575~1495 600~1560Maximum Number of Connected indoor Units 64 64

Trade condensing Unit Price £25,760.00 £27,129.00

VRV®III Condensing Units – Heat RecoveryREYQ-P9–Compact(46to48HP)

Page 67: Daikin AC Price List 2013

Price List 2013 65

VRV®

outdoor Units ReYQ8P9 ReYQ10P8 ReYQ12P9 ReYhQ16PReMQ8P9 ReMQ8P9

Capacity Nominal Cooling kW 22.40 28.00 33.50 45.00Nominal Heating kW 25.00 31.50 37.50 50.00

Dimensions Height mm 1680 1680 1680 1680 1680Width mm 1300 1300 1300 930 930Depth mm 765 765 765 765 765

Weight kg 331 331 331 204 204Air Flow Rate m3/sec 3.17 3.17 3.50 3.00 3.00Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 12 14 16 8.9 + 8.9Starting Current amps 74 74 75 4Fuse Rating amps 20 25 25 25 25

Refrigerant Circuit Refrigerant Type R410a R410aRefrigerant Charge kg 10.3 10.6 10.8 8.2 8.2Additional Charge kg data book data book

Sound Pressure dBA 58 58 60 58 58Piping limits Maximum length m 165 165 165 165

Maximum Vertical Rise m data book data bookPiping Connections - Systems

liquid inches 3/8 3/8 1/2 1/2Gas inches 3/4 7/8 1 1/8 1 1/8Discharge inches 5/8 3/4 3/4 N/A

Capacity index limit 100~260 125~325 150~390 200~520Maximum Number of Connected indoor Units 13 16 19 26

Trade condensing Unit Price £4,886.00 £5,368.00 £6,509.00 £9,772.00

VRV®III Condensing Units – Heat RecoveryREYQ-P9–HighCOP(upto16HP)

outdoor Units ReYQ18P9 ReYhQ20P ReYhQ22P ReYhQ24PReMQ8P9 ReMQ10P8 ReMQ8P9 ReMhQ12P8 ReMQ10P8 ReMhQ12P8 ReMhQ12P8 ReMhQ12P8

Capacity Nominal Cooling kW 50.40 55.90 61.50 67.00Nominal Heating kW 56.50 62.50 69.00 75.00

Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680Width mm 930 930 930 1240 930 1240 1240 1240Depth mm 765 765 765 765 765 765 765 765

Weight kg 204 254 204 334 254 334 334 334Air Flow Rate m3/sec 3.00 3.08 3.00 3.83 3.08 3.83 3.83 3.83Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 8.9 + 12.2 8.9 + 19.6 12.2 + 19.6 19.6 + 19.6Starting Current amps 78 79 88 88Fuse Rating amps 25 25 25 40 25 40 40 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 8.2 9.0 8 12 9 12 12 12Additional Charge kg data book

Sound Pressure dBA 58 58 58 60 58 60 60 60Piping limits Maximum length m 165

Maximum Vertical Rise m data bookPiping Connections - Systems

liquid inches 5/8 5/8 5/8 5/8Gas inches 1 1/8 1 1/8 1 1/8 1 3/8Discharge inches 7/8 1 1/8 1 1/8 1 1/8oil Equalising inches 3/4 3/4 3/4 3/4

Capacity index limit 225~585 250~650 275~715 300~780Maximum Number of Connected indoor Units 29 32 35 39

Trade condensing Unit Price £10,254.00 £12,490.00 £12,972.00 £15,208.00

VRV®III Condensing Units – Heat RecoveryREYQ-P9–HighCOP(18to24HP)

Page 68: Daikin AC Price List 2013

Integrated Solutions

VRV®

66

outdoor Units ReYaQ10P ReYaQ12P ReYaQ14P ReYaQ16PCapacity Nominal Cooling kW 28.00 33.50 40.00 45.00

Nominal Heating kW 31.50 37.50 45.00 50.00Dimensions Height x Width x Depth mm 1680 x 1300 x 765 1680 x 1300 x 765 1680 x 1300 x 765 1680 x 1300 x 765Weight kg 331 331 339 339Air Flow Rate m3/sec 3.17 3.50 3.92 4.00Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 22.1 22.3 32.8 33.0Starting Current amps 74 75 4 4Fuse Rating amps 25 25 40 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 10.6 10.8 11.1 11.1Additional Charge kg data book

Sound Pressure dBA 58 60 62 63Piping limits Maximum length m 100

Maximum Vertical Rise m data bookPiping Connections - Systems

liquid inches 3/8 1/2 1/2 1/2Gas inches 7/8 1 1/8 1 1/8 1 1/8Discharge inches 3/4 3/4 7/8 7/8

Capacity index limit - - - -Maximum Number of Connected indoor Units - - - -

Trade condensing Unit Price £4,467.00 £5,559.00 £6,552.00 £7,624.00

VRV®III Condensing Units – Heat Recovery ConnectiontoHTWaterModuleREYAQ

Notes:i) *The REYAQ Heat Recovery Condensing unit range is designed for connection to systems that incorporate the HXHD125 high temperature hot water module

in conjunction with the standard range of VRV® fan coil units.

outdoor Units RweYQ8P RweYQ10P RweYQ16P RweYQ18P RweYQ20P RweYQ24PRweYQ8P RweYQ10P RweYQ8P RweYQ8P RweYQ8P RweYQ10P RweYQ10P RweYQ10P RweYQ8P RweYQ8P RweYQ8P

Capacity Nominal Cooling kW 22.40 26.70 44.80 49.10 53.40 67.20Nominal Heating kW 25.00 31.50 50.00 56.50 63.00 75.00

Dimensions Height x Width x Depth mm 1000 x 780 x 550Weight kg 150 150 150 150 150 150 150 150 150 150 150Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 7.2 9.5 7.2 | 7.2 7.2 | 9.5 9.5 | 9.5 7.2 | 7.2 | 7.2Starting Current amps 4 4 4 4 4 4Fuse Rating amps 25 25 25 25 25 25 25 25 25 25 25

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 3.5 4.2 3.5 3.5 3.5 4.2 4.2 4.2 3.5 3.5 3.5Additional Charge kg data book data book data book data book data book data book

Sound Pressure dBA 50 51 50 | 50 50 | 51 51 | 51 50 | 50 | 50Piping limits Maximum length m 120 120 120 120 120 120

Maximum Vertical Rise m 50 50 50 50 50 50Piping Connections liquid inches 3/8 3/8 1/2 5/8 5/8 3/4

Gas inches 3/4 7/8 1 1/8 1 1/8 1 1/8 1 3/8Discharge pipe size - Heat Recovery only inches - - - - - -Capacity index limit 100~260 125~325 200~520 225~585 250~650 300~780Maximum Number of Connected indoor Units 13 16 26 29 32 36

Trade condensing Unit Price £5,416.00 £6,674.00 £10,832.00 £12,090.00 £13,348.00 £16,248.00

VRV®III Water Cooled Condensing Units HeatPumpandHeatRecoveryRWEYQ

Notes:Daikin have introduced the new VRV®iii Water Cooled condensing unit to compliment the rest of the VRV® range. The water cooled system has a number of advantages over an air cooled system:• suitablefortallmulti-storiedbuildingsduetonolimitationsofwaterpipinglength• wideoperationrangewithinletwatertemperaturesof10-45°C• suitableforusewithopenandclosedloopgroundsourcesystemsonrequest• thesystemoffersgreaterefficiencyinheatingmodeasthereisnodefrostcyclerequiredforthewaterloop• greaterefficienciesthanaircooledsystems

Page 69: Daikin AC Price List 2013

Price List 2013 67

VRV®

outdoor Units RweYQ26P RweYQ28P RweYQ30PRweYQ8P RweYQ8P RweYQ10P RweYQ8P RweYQ10P RweYQ10P RweYQ10P RweYQ10P RweYQ10P

Capacity Nominal Cooling kW 71.50 75.80 80.10Nominal Heating kW 81.50 88.00 94.50

Dimensions Height x Width x Depth mm 1000 x 780 x 550Weight kg 150 150 150 150 150 150 150 150 150Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 7.2 | 7.2 | 9.5 7.2 | 9.5 | 9.5 9.5 | 9.5 | 9.5Starting Current amps 4.0 4.0 4.0Fuse Rating amps 25 25 25 25 25 25 25 25 25

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 4 4 4 4 4 4 4 4 4Additional Charge kg data book

Sound Pressure dBA 50 | 50 | 51 50 | 51 | 51 51 | 51 | 51Piping limits Maximum length m 120 120 120

Maximum Vertical Rise m 50 50 50Piping Connections liquid inches 3/4 3/4 3/4

Gas inches 1 3/8 1 3/8 1 3/8Discharge pipe size - Heat Recovery only inches - - -Capacity index limit 325~845 350~910 375~975Maximum Number of Connected indoor Units 36 36 36

Trade condensing Unit Price £17,506.00 £18,764.00 £20,022.00

VRV®III Water Cooled Condensing Units HeatPumpandHeatRecoveryRWEYQ

Notes:The new VRV®-Wiii system is supplied as a common unit and can be used in either heat pump and heat recovery modes, from size 10 to size 30 all using a three phase power supply. The 30 hp system can connect to up to 36 indoor units. The system is fully compatible with the full range of existing VRV® fan coils and controls packages.The condensing unit is small with a foot print of 780 x 550 mm and a height of 1000 mm. Running quality with a sound pressure level of 51dB(A), it should be installed in a plant room.

Independent Unit outdoor Unit RweYQ8PR RweYQ10PRCapacity Cooling kW 22.4 26.7

Heating kW 25 31.5Dimensions Unit Height mm 1,000

Width mm 780Depth mm 550

Weight Unit kg 149 150Sound Pressure (Nominal)

Cooling dBA 50 51

inlet Water Temperature

Cooling °C 10~45 Heating °C -10~45

Refrigerant R-410A Power Supply 3~/400V/50Hz Piping connections liquid (oD) HP / HR mm 9.52 / 9.52

Gas HP / HR mm - / 19.1 - / 22.2 Discharge gas HP / HR mm 19.1 / 15.9 22.2 / 19.1 Max total length m 300

Max no. of indoor units to be connected 13 16

Trade condensing Unit Price £5,416.00 £6,674.00

VRV®III Water Cooled Condensing Units GeothermalApplicationRWEYQ-PRheating with ground sourced water as a renewable energy source!• Groundwater remains at a relatively constant temperature during the year• Superior efficiency remains even at extreme outdoor temperatures• Uses renewable energy: closed loop energy transfer with ground,

lake and river

Extension of the operation range down to -10°C in heating:• Add ethylene glycol to the water when the water inlet temperature is

lower than 5°C• No multi combinations possible• Heat Pump and Heat Recovery systems

Page 70: Daikin AC Price List 2013

Integrated Solutions

VRV®

68

VRV®

Benefits:

• Dramatically reduced installed cost – up to 50% saving compared with a complete new system

• Re-use all existing pipework and possibly existing fan coils

• Flexibility to use with existing pipework connected to other non-Daikin systems

• Automatic charging and pipework cleaning function

• Higher energy efficiency of up to 50% and lower CO

2 emissions than retrofitting

refrigerant

• Major potential to increase system capacity

10 HP 16 HP

1.

2.

1. Keep main piping 2. Add indoor units

R22 is a hydrochlorofluorocarbon (HCFC) which was commonly used in air conditioning systems. However, both new and recycled sources of R22 are banned from January 2015. Many systems today are still running on R22, but as supplies of R22 run low, now’s the time to replace R22 systems. The good news is that Daikin’s VRV-Q solution delivers significantly higher energy efficiencies, with the potential of saving up to 50%, compared with installing a completely new system.

Replacement VRV®: VRV®III-Q

The benefits:Increasing efficienciesUpgradinganoldR22systemtoaVRV®-Qsystemwillincreasesystem efficiency by more than 40%, thanks to recent developments in heat pump technology and the more efficient R-410A refrigerant.

Fast installationInstallation is quicker because the existing piping and indoor units (in some cases) can be retained, while Daikin’s unique automatic refrigerant charging and refrigerant pipe cleaning cuts installation time too.

System history doesn’t restrict future usabilityAs a result of the combined refrigerant pipe cleaning and automatic charging function, the piping network is completely clean and suitable for re-use.

Limited and planned downtimeThe installation is less intrusive and time consuming than for a completely new system. Downtime can be carefully planned, whereas if a problem occurs when not enough reclaimed R22 is available, a long and unplanned downtime may occur.

Phased investment costBecause the entire R22 system does not need to be replaced, it is possible to upgrade the system in phases. The R22 replacement programme can therefore be incorporated in the general refurbishment schedule of the building, thus spreading the investment cost.

WarrantyUnlikeusingdrop-inrefrigerants,theVRV®-Qcondensingunitisprovided with a manufacturer’s warranty, providing the existing pipework condition is deemed suitable for re-use (see price list).

Possibility to increase capacityCooling loads often increase subsequent to the initial installation oftheairconditioningsystem.TheReplacementVRV®(VRV®-Q)enables system capacity to be increased without changing the refrigerant piping (depending on system characteristics). For example:Itispossibletoinstalla16HPReplacementVRV®ontherefrigerant piping of an R-22 10 HP system.

Page 71: Daikin AC Price List 2013

Price List 2013 69

VRV®

outdoor Units RQYQ140P RQYQ8P RQYQ10P RQYQ12P RQYQ14P RQYQ16PCapacity Nominal Cooling kW 14.00 22.40 28.00 33.50 40.00 45.00

Nominal Heating kW 16.00 25.00 31.50 37.50 45.00 50.00Dimensions Height mm 1680 1680 1680 1680 1680 1680

Width mm 635 930 930 930 1240 1240Depth mm 765 765 765 765 765 765

Weight kg 175 230 284 284 381 381Air Flow Rate m3/sec 1.58 3.00 3.08 3.33 3.88 3.88External Static Pressure High Pa 78 78 78 78 78 78Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 5.5 8.9 12.2 14.9 19.6 22.5Starting Current amps 4 4 74 75 84 85Fuse Rating amps 15 25 25 25 35 35

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 11.1 10.8 11.7 11.7 11.7 11.7Additional Charge kg data book

Sound Pressure dBA 54 57 58 60 60 60Piping limits Maximum length m 150

Maximum Vertical Rise m 50Piping Connections liquid inches 3/8 3/8 3/8 1/2 1/2 1/2

Gas inches 5/8 3/4 7/8 1 1/8 1 1/8 1 1/8Capacity index limit 62.5~162.5 100~260 125~325 150~390 175~455 200~520Maximum Number of Connected indoor Units 10 17 21 26 30 34

Trade condensing Unit Price £4,254.00 £5,344.00 £5,840.00 £7,150.00 £8,342.00 £9,628.00

VRV®III-Q Condensing Unit – Heat PumpRQYQ-P(upto16HP)

Please see note on page 74 regardingVRV®III-Qwarranty,andcontactyourlocalsalesofficeformoreinformationonVRV®III-Qinstallation.

outdoor Units RQYQ18P RQYQ20P RQYQ22P RQYQ24PRQYQ8P RQYQ10P RQYQ8P RQYQ12P RQYQ10P RQYQ12P RQYQ12P RQYQ12P

Capacity Nominal Cooling kW 50.40 55.90 61.50 67.00Nominal Heating kW 56.50 62.50 69.00 75.00

Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680Width mm 930 930 930 930 930 930 930 930Depth mm 765 765 765 765 765 765 765 765

Weight kg 230 284 230 284 284 284 284 284Air Flow Rate m3/sec 3.00 3.08 3.00 3.33 3.08 3.33 3.33 3.33Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 21.1 23.8 27.1 29.8Starting Current amps 78.0 79.0 88.0 88.0Fuse Rating amps 25 25 25 25 25 25 25 25

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 10.8 11.7 10.8 11.7 11.7 11.7 11.7 11.7Additional Charge kg data book

Sound Pressure dBA 57 58 57 60 58 60 60 60Piping limits Maximum length m 150

Maximum Vertical Rise m 50Piping Connections liquid inches 5/8 5/8 5/8 5/8

Gas inches 1 1/8 1 1/8 1 1/8 1 3/8Discharge inches - -oil Equalising inches - -

Capacity index limit 225~585 250~650 275~715 300~780Maximum Number of Connected indoor Units 39 43 47 52

Trade condensing Unit Price £11,184.00 £12,494.00 £12,990.00 £14,300.00

VRV®III-Q Condensing Unit – Heat PumpRQYQ-P(18to24HP)

Please see note on page 74 regardingVRV®III-Qwarranty,andcontactyourlocalsalesofficeformoreinformationonVRV®III-Qinstallation.

Page 72: Daikin AC Price List 2013

Integrated Solutions

VRV®

70

outdoor Units RQYQ26P RQYQ28P RQYQ30P RQYQ32PRQYQ10P RQYQ16P RQYQ12P RQYQ16P RQYQ14P RQYQ16P RQYQ16P RQYQ16P

Capacity Nominal Cooling kW 73.00 78.50 84.00 90.00Nominal Heating kW 81.50 87.50 94.50 100.00

Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680Width mm 930 1240 930 1240 1240 1240 1240 1240Depth mm 765 765 765 765 765 765 765 765

Weight kg 284 381 284 381 381 381 381 381Air Flow Rate m3/sec 3.08 3.88 3.33 3.88 3.88 3.88 3.88 3.88Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 34.7 37.4 42.1 45.0Starting Current amps 98.0 98.0 108.0 109.0Fuse Rating amps 25 35 25 35 35 35 35 35

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 11.7 11.7 11.7 11.7 11.7 11.7 11.7 11.7Additional Charge kg data book

Sound Pressure dBA 58 60 60 60 60 60 60 60Piping limits Maximum length m 150

Maximum Vertical Rise m 50Piping Connections liquid inches 3/4 3/4 3/4 3/4

Gas inches 1 3/8 1 3/8 1 3/8 1 3/8Discharge inches - -oil Equalising inches - -

Capacity index limit 325~845 350~910 375~975 400~1040Maximum Number of Connected indoor Units 56 60 64 64

Trade condensing Unit Price £15,468.00 £16,778.00 £17,970.00 £19,256.00

VRV®III-Q Condensing Unit – Heat PumpRQYQ-P(26to32HP)

Please see note on page 74 regardingVRV®III-Qwarranty,andcontactyourlocalsalesofficeformoreinformationonVRV®III-Qinstallation.

outdoor Units RQYQ34P RQYQ36P RQYQ38PRQYQ10P RQYQ10P RQYQ14P RQYQ10P RQYQ10P RQYQ16P RQYQ10P RQYQ12P RQYQ16P

Capacity Nominal Cooling kW 96.00 101.00 107.00Nominal Heating kW 108.00 113.00 119.00

Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680 1680Width mm 930 930 1240 930 930 1240 930 930 1240Depth mm 765 765 765 765 765 765 765 765 765

Weight kg 284 284 381 284 284 381 284 284 381Air Flow Rate m3/min 185 185 233 185 185 233 185 200 233External Static Pressure High Pa 78 78 78Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 44.0 49.6 49.6Starting Current amps 110 111 111Fuse Rating amps 25 25 35 25 25 35 25 25 35

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 11.7 11.7 11.7 11.7 11.7 11.7 11.7 11.7 11.7Additional Charge kg data book

Sound Pressure dBA 58 58 60 58 58 60 58 60 60Piping limits Maximum length m 150

Maximum Vertical Rise m 50Piping Connections liquid inches 3/4 3/4 3/4

Gas inches 1 3/8 1 5/8 1 5/8Capacity index limit 425~1105 450~1170 475~1235Maximum Number of Connected indoor Units 64 64 64

Trade condensing Unit Price £20,022.00 £21,308.00 £22,618.00

VRV®III-Q Condensing Unit – Heat PumpRQYQ-P(34to38HP)

Please see note on page 74 regardingVRV®III-Qwarranty,andcontactyourlocalsalesofficeformoreinformationonVRV®III-Qinstallation.

Page 73: Daikin AC Price List 2013

Price List 2013 71

VRV®

outdoor Units RQYQ40P RQYQ42P RQYQ44PRQYQ12P RQYQ12P RQYQ16P RQYQ10P RQYQ16P RQYQ16P RQYQ12P RQYQ16P RQYQ16P

Capacity Nominal Cooling kW 112.00 118.00 124.00Nominal Heating kW 125.00 132.00 138.00

Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680 1680Width mm 930 930 1240 930 1240 1240 930 1240 1240Depth mm 765 765 765 765 765 765 765 765 765

Weight kg 284 284 381 284 381 381 284 381 381Air Flow Rate m3/min 200 200 233 185 233 233 200 233 233External Static Pressure High Pa 78 78 78Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 52.3 57.2 59.9Starting Current amps 111 122 122Fuse Rating amps 25 25 35 25 35 35 25 35 35

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 11.7 11.7 11.7 11.7 11.7 11.7 11.7 11.7 11.7Additional Charge kg data book

Sound Pressure dBA 60 60 60 58 60 60 60 60 60Piping limits Maximum length m 150

Maximum Vertical Rise m 50Piping Connections liquid inches 3/4 3/4 3/4

Gas inches 1 5/8 1 5/8 1 5/8Capacity index limit 500~1300 525~1365 550~1430Maximum Number of Connected indoor Units 64 64 64

Trade condensing Unit Price £23,928.00 £25,096.00 £26,406.00

VRV®III-Q Condensing Unit – Heat PumpRQYQ-P(40to44HP)

Please see note on page 74 regardingVRV®III-Qwarranty,andcontactyourlocalsalesofficeformoreinformationonVRV®III-Qinstallation.

outdoor Units RQYQ46P RQYQ48PRQYQ14P RQYQ16P RQYQ16P RQYQ16P RQYQ16P RQYQ16P

Capacity Nominal Cooling kW 130.00 135.00Nominal Heating kW 145.00 150.00

Dimensions Height mm 1680 1680 1680 1680 1680 1680Width mm 1240 1240 1240 1240 1240 1240Depth mm 765 765 765 765 765 765

Weight kg 381 381 381 381 381 381Air Flow Rate m3/min 233 233 233 233 233 233External Static Pressure High Pa 78 78Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 64.6 67.5Starting Current amps 132 134Fuse Rating amps 35 35 35 35 35 35

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 11.7 11.7 11.7 11.7 11.7 11.7Additional Charge kg data book

Sound Pressure dBA 60 60 60 60 60 60Piping limits Maximum length m 150

Maximum Vertical Rise m 50Piping Connections liquid inches 3/4 3/4

Gas inches 1 5/8 1 5/8Capacity index limit 575~1495 600~1560Maximum Number of Connected indoor Units 64 64

Trade condensing Unit Price £27,598.00 £28,884.00

VRV®III-Q Condensing Unit – Heat PumpRQYQ-P(46to48HP)

Please see note on page 74 regardingVRV®III-Qwarranty,andcontactyourlocalsalesofficeformoreinformationonVRV®III-Qinstallation.

Page 74: Daikin AC Price List 2013

Integrated Solutions

VRV®

72

outdoor Units RQceQ280P RQceQ360P RQceQ460PRQeQ140P RQeQ140P RQeQ180P RQeQ180P RQeQ140P RQeQ140P RQeQ180P

Capacity Nominal Cooling kW 28.00 36.00 45.00Nominal Heating kW 32.00 40.00 52.00

Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680Width mm 635 635 635 635 635 635 635Depth mm 765 765 765 765 765 765 765

Weight kg 175 175 175 175 175 175 175Air Flow Rate m3/sec 1.58 1.58 1.58 1.58 1.58 1.58 1.58External Static Pressure High Pa 78 78 78Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 5.5+5.5 8.0+8.0 5.5+5.5+8.0Starting Current amps 4 4 4Fuse Rating amps 15 15 20 20 15 15 20

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 10.3 10.3 10.6 10.6 10.3 10.3 10.6Additional Charge kg data book

Sound Pressure dBA 54 54 58 58 54 54 58Piping limits Maximum length m 120 120 120

Maximum Vertical Rise m 50Piping Connections liquid inches 3/8 1/2 1/2

Gas inches 7/8 1 1 1/8Capacity index limit 125~325 162.5~422.5 200~520Maximum Number of Connected indoor Units 16 20 26

Trade condensing Unit Price £6,442.00 £8,284.00 £10,584.00

VRV®III-Q Condensing Unit – Heat RecoveryRQCEQ-P (28.0 to 45.0 kW)

Please see note on page 74 regardingVRV®III-Qwarranty,andcontactyourlocalsalesofficeformoreinformationonVRV®III-Qinstallation.

outdoor Units RQceQ500P RQceQ540P RQceQ636PRQeQ140P RQeQ180P RQeQ180P RQeQ180P RQeQ180P RQeQ180P RQeQ212P RQeQ212P RQeQ212P

Capacity Nominal Cooling kW 50.00 54.00 63.60Nominal Heating kW 56.00 60.00 67.20

Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680 1680Width mm 635 635 635 635 635 635 635 635 635Depth mm 765 765 765 765 765 765 765 765 765

Weight kg 175 175 175 175 175 175 179 179 179Air Flow Rate m3/sec 1.58 1.58 1.58 1.58 1.58 1.58 1.83 1.83 1.83Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 5.5+8.0+8.0 8.0+8.0+8.0 11.5+11.5+11.5Starting Current amps 4 4 4Fuse Rating amps 15 20 20 20 20 20 20 20 20

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 10 11 11 11 11 11 11 11 11Additional Charge kg data book

Sound Pressure dBA 54 58 58 58 58 58 60 60 60Piping limits Maximum length m 120

Maximum Vertical Rise m 50Piping Connections liquid inches 5/8 5/8 5/8

Gas inches 1 1/8 1 1/8 1 1/8Discharge inches 7/8 7/8 1oil Equalising inches - - -

Capacity index limit 225~585 250~650 275~715Maximum Number of Connected indoor Units 29 33 36

Trade condensing Unit Price £11,505.00 £12,426.00 £14,643.00

VRV®III-Q Condensing Unit – Heat RecoveryRQCEQ-P (50.0 to 63.6 kW)

Please see note on page 74 regardingVRV®III-Qwarranty,andcontactyourlocalsalesofficeformoreinformationonVRV®III-Qinstallation.

Page 75: Daikin AC Price List 2013

Price List 2013 73

VRV®

outdoor Units RQceQ712P RQceQ744PRQeQ140P RQeQ180P RQeQ180P RQeQ212P RQeQ140P RQeQ180P RQeQ212P RQeQ212P

Capacity Nominal Cooling kW 71.20 74.40Nominal Heating kW 78.40 80.80

Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680Width mm 635 635 635 635 635 635 635 635Depth mm 765 765 765 765 765 765 765 765

Weight kg 175 175 175 179 175 175 179 179Air Flow Rate m3/sec 1.58 1.58 1.58 1.83 1.58 1.58 1.83 1.83Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 5.5+8.0+8.0+11.5 5.5+8.0+11.5+11.5Starting Current amps 4 4Fuse Rating amps 15 20 20 20 15 20 20 20

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 10.3 10.6 10.6 11.2 10.3 10.6 11.2 11.2Additional Charge kg data book

Sound Pressure dBA 54 58 58 60 54 58 60 60Piping limits Maximum length m 120

Maximum Vertical Rise m 50Piping Connections liquid inches 5/8 3/4

Gas inches 1 1/8 1 3/8Discharge inches 1 1oil Equalising inches - -

Capacity index limit 300~780 325~845Maximum Number of Connected indoor Units 40 43

Trade condensing Unit Price £16,386.00 £17,125.00

VRV®III-Q Condensing Unit – Heat RecoveryRQCEQ-P (71.2 to 74.4 kW)

Please see note on page 74 regardingVRV®III-Qwarranty,andcontactyourlocalsalesofficeformoreinformationonVRV®III-Qinstallation.

outdoor Units RQceQ816P RQceQ848PRQeQ180P RQeQ212P RQeQ212P RQeQ212P RQeQ212P RQeQ212P RQeQ212P RQeQ212P

Capacity Nominal Cooling kW 81.60 84.80Nominal Heating kW 87.20 89.60

Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680Width mm 635 635 635 635 635 635 635 635Depth mm 765 765 765 765 765 765 765 765

Weight kg 175 179 179 179 179 179 179 179Air Flow Rate m3/sec 1.58 1.83 1.83 1.83 1.83 1.83 1.83 1.83Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 8.0+11.5+11.5+11.5 11.5+11.5+11.5+11.5Starting Current amps 4 4Fuse Rating amps 20 20 20 20 20 20 20 20

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 10.6 11.2 11.2 11.2 11.2 11.2 11.2 11.2Additional Charge kg data book

Sound Pressure dBA 58 60 60 60 60 60 60 60Piping limits Maximum length m 120

Maximum Vertical Rise m 50Piping Connections liquid inches 3/4 3/4

Gas inches 1 3/8 1 3/8Discharge inches 1 1/8 1 1/8oil Equalising inches - -

Capacity index limit 350~910 375~975Maximum Number of Connected indoor Units 47 50

Trade condensing Unit Price £18,785.00 £19,524.00

VRV®III-Q Condensing Unit – Heat RecoveryRQCEQ-P (81.6 to 84.8 kW)

Please see note on page 74 regardingVRV®III-Qwarranty,andcontactyourlocalsalesofficeformoreinformationonVRV®III-Qinstallation.

Page 76: Daikin AC Price List 2013

Integrated Solutions

VRV®

74

VRV®III-Q WarrantyWarranty and Site ServicesThewarrantyforVRV®III-Qsystemsoperatesunderdifferentconditionstoour standard warranty. To ensure complete suitability of the existing site, a choice of optional warranty and special site services packages are available from Daikin Airconditioning UK Ltd. These choices will ensure the VRV®III-Qsystemisdesignedandcommissionedtoprovidetheclientwithcomplete ‘peace of mind’ operation.

The choices include:

a) Pre-order checks on the existing pipework and fan coils installed on the clientssitetoensuresuitabilityforVRV®III-Qinstallation

b)CommissioningofthenewVRV®III-Qinstallationtoensurecorrectandefficient operation

c) DNSS EcoSave remote diagnostics and preventative monitoring system

Warranty options for 3 or 5 years are available depending on the combination of choices chosen, and the condition that equipment is installedandcommissionedbyanengineertrainedandapprovedforVRV®equipment by Daikin Airconditioning UK Ltd.

Commissioning Log Books will need to be submitted to Daikin Airconditioning UK Ltd to activate the warranty.

The tables below provide an overview of the choices, with a brief description on page 75. For full details please contact your local sales office.

warranty Package Level For site with existing Fan coils standard silver Gold

Condensing Unit Warranty Period 3 Years 3 Years 5 Years Fan Coil Unit Warranty Period 0 Years 1 Year 1 Year

Site Pre-order inspection

By Approved Engineer - - -By Daikin Airconditioning UK ltd 3 3 3

Commissioning By Approved Engineer 3 - -By Daikin Airconditioning UK ltd Additional Cost option 3 3

DNSS Daikin DNSS EcoSave Monitoring - 3 3

Net Price Price per complete System for full warranty period

8-13HP £175 £1,130 £1,50016-22HP £175 £1,280 £1,75024-30HP £175 £1,430 £2,000

order Code 8-13HP UK.FSVQ/E/STAND UK.FSVQ/E/SV/8-13 UK.FSVQ/E/GD/8-13 16-22HP UK.FSVQ/E/STAND UK.FSVQ/E/SV/16-22 UK.FSVQ/E/GD/16-22 24-30HP UK.FSVQ/E/STAND UK.FSVQ/E/SV/24-30 UK.FSVQ/E/GD/24-30

warranty Package Level For site with New Fan coils standard silver Gold

Condensing Unit Warranty Period 3 Years 5 Years 5 Years Fan Coil Unit Warranty Period 3 Years 5 Years 5 Years

Site Pre-order inspection

By Approved Engineer 3 3 3

By Daikin Airconditioning UK ltd Additional Cost option Additional Cost option Additional Cost option Commissioning By Approved Engineer 3 - -

By Daikin Airconditioning UK ltd - 3 3

DNSS Daikin DNSS EcoSave Monitoring - - 3

Net Price Price per complete System for full warranty period

8-13HP £0 £400 £1,32516-22HP £0 £400 £1,57524-30HP £0 £400 £1,825

order Code 8-13HP UK.FSVQ/N/STAND UK.FSVQ/N/SV/8-13 UK.FSVQ/N/GD/8-13 16-22HP UK.FSVQ/N/STAND UK.FSVQ/N/SV/16-22 UK.FSVQ/N/GD/16-22 24-30HP UK.FSVQ/N/STAND UK.FSVQ/N/SV/24-30 UK.FSVQ/N/GD/24-30

VRV®III-Q Warranty Choices

Notes:i) All prices shown are Net. No further discount can be applied.

1. VRV®III-Q combined with existing fan coil units

2. VRV®III-Q combined with new fan coil units

Page 77: Daikin AC Price List 2013

Price List 2013 75

VRV®

Approved engineerAn approved engineer is an engineer who:1. Is suitably registered in accordance with F-gas regulations;2. HassuccessfullycompletedaDaikinAirconditioningUKLtdVRV®IIIAirCooled

installation and commissioning course within the last 3 years.

Net priceNet price, exclusive of VAT and subject to our standard terms and conditions. No other discounts are applicable.Prices shown for site pre-order inspection and commissioning are for work undertaken during normal working hours between 09:00 and 17:30. Any requests for attendance to site out of these hours is subject to additional charges.

WarrantyToactivatethewarrantytheDaikinAirconditioningUKLtdVRV®CommissioningLog Book will need to be fully completed and submitted to Daikin Airconditioning UK Ltd FQS department for checking. Upon receipt and validation that all required details are provided and satisfactory, Daikin Airconditioning UK Ltd will issue a confirmation letter that the warranty is activated. Where Daikin Airconditioning UK Ltd will complete the commissioning we will provide a copy of the Commissioning Log Book to the installation contractor. Except where mentioned above, our standard warranty conditions will apply. If none of the packaged options are chosen, then the warranty will be limited to a standard 12 month parts only cover.

Site pre-order inspectionWhere included in the package, Daikin Airconditioning UK Ltd will attend the site to check the suitability of the existing equipment and pipework for connection toVRV®-IIIQ.Whereitisnotpossibletocheckoperationorequipmentcondition,this will also be highlighted in the final report, and appropriate recommendations made.

If an approved engineer carries out the site inspection, then a Daikin Airconditioning UK Ltd supplied form shall be completed and submitted to our FQS department for checking and approval prior to any order being accepted.

The pre-order site inspection will include for the following items.• Existing system(s) capacity – necessary to estimate required system load for

the new system •Recordallthemodelnumbersandtheserialnumbersfortheindoorandthe

outdoor units and indicate actual installed system combinations

• Check status of the existing indoor units – necessary if the existing units are to be reused

•Checkfiltercondition •Checkcoilcondition •Checkfanmotoroperation–selectfanonlyandcheckforairmovementand

for unusual noise and vibration

• Installed pipework details – necessary to check compliance with the manufacturer’s specification and assess install quality. This would highlight any required rectification prior to the installation of the new system

•Provideasinstalledpipeworkdiagrams.Ifnotavailable,provideasinstalledpipe work schematics from information gathered on site

•Checkthedistancefromtheoutdoortothefarthestindooralongthepipe work route

•CheckthedistancefromthefirstRefnetfittingtothefarthestindoorunit •Checktheheightdifferencebetweentheoutdoorandthelowestindoor

when the outdoor is situated above the indoor units or height difference between the outdoor and the highest indoor if the outdoor is situated below the indoor units

•Checktheheightdifferencebetweenthehighestandthelowestindoorconnected to the same system

•Providethelengthsofallinstalledpipesizes •ChecktheinstallationpositionandangleoftheRefnetJoints •Checktheconditionofthepipeinsulation •Checktheadequacyoftheexistingpipesupports

• Installed communication and control wiring – necessary to check compliance with the manufacturer’s specification, suitability for the new system and suitability for new controls specification

•Checksizesandtypeoftheinterconnectingcommunicationcablesbetweenindoor units, outdoor units and any central control systems

•Checktheseparationbetweenthepowerwiringandtheinstalled controls wiring

• Power wiring to the outdoor units – necessary to check suitability for the new outdoor units

•Checksupplyvoltage •Checknumberofoutletsavailableadjacenttotheoutdoorunitscompound. •Checkfuse/MCBsizesandtypes •Checkstatusoftheisolators

VRV®III-Q Warranty Detail

Page 78: Daikin AC Price List 2013

Integrated Solutions

VRV®

76

• System health check – it is important to know if the existing systems are operating to their optimum. If there are issues which may affect the new installation they need to identified and rectified before installation of the new system. A comprehensive list of the operating data can be collected byconnectingaVRV®Checkertoeachsystemandrecordingaminimumofone hour operation data for analysis. This data should be sent back to Daikin Airconditioning UK Ltd FQS department for analysis

•Operatethewholesystemincoolingfor½hourandinheatingfor½hourtocollect representative data

•SenddatatoDaikinAirconditioningUKLtdFQSdepartmentforanalysis

• System history check –althoughthenewVRV®-IIIQsystemisdesignedto re-use existing pipework and in some cases existing indoor units it is still necessary to know the existing systems operational history to judge its integrity for the new application

•Checkforpresenceofleakprotectiondyeandacidlevel–usetotaltestkit •EnsurethatnoAcidAwaychemicalhaseverbeenaddedtothesystem

refrigerant charge

• Existing system controls – investigate currently installed local controls, centralised controls and connection to the third party systems. This is particularly necessary if any existing controls are planned to be re-used

CommissioningDependant on the warranty package chosen, either an approved engineer or Daikin Airconditioning UK Ltd will provide system commissioning on the completed installation. As mentioned in the warranty section above, a completed log book will need to be submitted to activate the warranty

Commissioning where not provided by Daikin Airconditioning UK Ltd, canonly be completed by an approved engineer

Where Daikin Airconditioning UK Ltd provide commissioning as part of thepackage this shall include:• Checkinstallationofnewunits–ensurenewpipingisinstalledcorrectto

Daikin specification• Checkpowersupplies–localisolators,MCBrating• Fillinmodelnumberdata,serialnumbersetctocommissioninglogbook;• InitialiseVRV®Systemandensureallunitscommunicate• Setupadditionalcontrolsystems–ITC,Bacnetandprovidedemonstration• Chargeadditionalrefrigerant• Perform“Test”operation–including“Automatic”chargingfunction• Connectservicecheckerandmonitoroperation–Cool>Heat>HeatRecovery• CompleteCommissioningLogBook• Provideadditionalcommentsandrecommendationsifnecessary• Leaveoperationsetasrequiredbyclient

Prior to our site attendance the following shall be completed:• Allcommunicationwiringiscompleteandterminatedcorrectly• Allelectricalworkiscompleteandcorrect(supplywiringtypeandsize–

breaker size correct)• Allsystemspipinghasbeenpressuretestedto33Bar• Allsystemspipingisevacuatedto<5Torr• Allsystemspipinghasbeenmeasuredandisavailableforourinformation• Sufficientadditionalrefrigerantisavailableontheday

Any other works other than those detailed above are excluded.

DNSS (Daikin Network Service System)Where Daikin Airconditioning UK Ltd provide DNSS as part of the packagethis shall include the following items:• CommissioningofDNSSsystem(onsiteservice)• GPRSrouterandSIM(thiswillbepropertyofDaikinAirconditioningUKLtd)• Remoteenergysavingservice• 24/7monitoringofVRV®operatingdata• Instantnotificationofsystemmalfunction(email)7daysaweek• Malfunctionpredictionservice(duringofficehours09.00-17.30)• Bi-annualenergysavingreportindicatingelectricitycostsavingandreduction

in CO2 emissions

• Recommendationstoimproveoperatingsettings• IssueofaDNSSuserpack

AlloftheabovewillbeprovidedforthewarrantyperiodoftheVRV®(either3or5years) depending on the package selected.

Prior to our site attendance the following shall be completed:• AdevicecompatiblewithDNSSisinstalledonsite–DaikinIntelligentManager,

Daikin Intelligent Touch Controller or Daikin LC controller. (Not included in the price of the monitoring package)

• Allelectricalworkiscompleteandcorrect(supplywiringtypeandsize– breaker size correct) also F1/F2 communications are installed

• Afullsetofasinstalleddrawingsareavailable–indicatingsystemconfigurations, installation locations and room references

• ApowersourceisinstalledfortheGPRSmodemnearthecontroldevice– this can be powered from a standard socket

• Aconnectiontotheinternetisavailable–forareaswherethereispoorGPRScoverage a LAN or analogue phone connection must be installed near the control device. (Installation and rental costs are not included in the price of the monitoring package)

• FullaccessmustbemadeavailabletotheVRV®equipmentandifanyaccessequipment is required Daikin UK must be informed prior to the site visit

• AlistofcontactsmustbeissuedtoDaikinAirconditioningUKLtd(theseare the contacts that should be e-mailed or telephoned in the event of a malfunction or error with the air conditioning system). If these change in the future, information will be given in the user pack for how to notify Daikin Airconditioning UK Ltd of the changes

ThisisanextractfromtheDaikinpublication“WarrantyandSiteServicesPackage forVRV-IIIQ”.Pleasecontactyourlocalsalesofficetoreceiveacopyandobtain further information.

VRV®III-Q Warranty Detail

Page 79: Daikin AC Price List 2013

Price List 2013 77

VRV®

VRV® Accessories

Page 80: Daikin AC Price List 2013

Integrated Solutions

VRV®

78

outdoor Units single Boxes Multi BoxesBsVQ100P8B BsVQ160P8B BsVQ250P8B BsV4Q100PV BsV6Q100PV

Dimensions Height mm 207 209Width mm 388 1050 1577Depth mm 326 635

Weight kg 14 14 15 60 87Total indoor Capacity 20 ~ 100 20 ~ 160 161 ~ 250 (4 no) 20-100 (6 no) 20-100Number of Fan Coil Units 5 8 8 4-20 * 6-30 **Electrical Details Power Supply Phase 1

Hz 50V 230

Running Current amps 0.1 0.1 0.1 TBA TBAFuse Rating amps 5 5 5 TBA TBA

Piping limits level Difference m data bookMaximum length m

Piping Connections indoor

liquid inches 3/8 3/8 3/8 3/8 3/8Gas inches 5/8 5/8 7/8 5/8 5/8

Piping Connections outdoor

liquid inches 3/8 3/8 3/8 1/2 5/8Suction inches 5/8 5/8 7/8 3/4 1 1/8Discharge inches 1/2 1/2 3/4 1 1/8 1 1/8

Trade accessory price £330.00 £364.00 £418.00 £1,317.00 £2,002.00

* BSV4Q100PV MUST have the minimum of one indoor unit connected to at least 3 of the 4 no outlets** BSV6Q100PV MUST have the minimum of one indoor unit connected to at least 5 of the 6 no outlets

VRV®III Heat Recovery Branch Selector Boxes BSVQ

For outdoor Units 2-Pipe system Refrigerant sizing between Refnet Joints and Indoor/outdoor Units RXYsQ / RYYQ / RweYQ / eMRQ Trade PriceTotal capacity of

Indoor UnitsLiquid

Pipesuction

PipeRefnet

selectionRXYQ5P/RXYsQ4-6Pa

Below 62.5 1/4 1/2 KHRQ22M20T £28.0062.5 to 162.5 3/8 5/8 KHRQ22M20T £28.00

RYYQ8-54T/ eMRQ8aa-16aa

Below 150 3/8 5/8 KHRQ22M20T £28.00150 to below 200 3/8 3/4 KHRQ22M20T £28.00200 to below 290 3/8 7/8 KHRQ22M29T9 £35.00290 to below 420 1/2 1 1/8 KHRQ22M64T £37.00

420 to 639 5/8 1 1/8 KHRQ22M64T £37.00640 and above Please contact your local sales office for selection KHRQ22M75T £47.00

Refnet Header KHRQ22M29H £111.00Refnet Header KHRQ22M64H £136.00Refnet Header KHRQ22M75H £178.00

Condensing Unit Branch Kit - 2 Module RYYQ, RWEYQ BHFQ22P1007 £76.00Condensing Unit Branch Kit - 3 Module RYYQ BHFQ22P1517 £150.00Condensing Unit Branch Kit - 2 Module RQYQ BHFP22P36C £94.00Condensing Unit Branch Kit - 3 Module RQYQ BHFP22P54C £187.00

For outdoor Units 3-Pipe system Refrigerant sizing between Refnet Joints and Indoor/outdoor Units ReYQ / RweYQ / eMRQ Trade PriceTotal capacity of

Indoor UnitsLiquid

PipeDischarge

Pipesuction

PipeRefnet

selectionReY(h)Q8-24P/ ReYQ8-48P8/P9/ RweYQ8-30P/ eMRQ8aa-16aa

Below 150 3/8 1/2 5/8 KHRQ23M20T £41.00150 to below 200 3/8 5/8 3/4 KHRQ23M20T £41.00200 to below 290 3/8 3/4 7/8 KHRQ23M29T9 £53.00290 to below 420 1/2 3/4 1 1/8 KHRQ23M64T £56.00

420 to 639 5/8 1 1/8 1 1/8 KHRQ23M64T £56.00640 and above Please contact your local sales office for selection KHRQ23M75T £70.00

Refnet Header KHRQ23M29H £153.00Refnet Header KHRQ23M64H £186.00Refnet Header KHRQ23M75H £261.00

Condensing Unit Branch Kit - 2 Module REYQ, RWEYQ BHFQ23P907 £142.00Condensing Unit Branch Kit - 3 Module REYQ, RWEYQ BHFQ23P1357 £287.00

Condensing Unit Branch Kit - 2 Module RQEQ BHFP26P36C £160.00Condensing Unit Branch Kit - 3 Module RQEQ BHFP26P63C £326.00Condensing Unit Branch Kit - 4 Module RQEQ BHFP26P84C £433.00

VRV® Condensing Unit Refnet Joints

Page 81: Daikin AC Price List 2013

Price List 2013 79

VRV®

VRV® Accessories Remote Controllers (supplied loose)VRV® Remote control options

Model Description Related Fan coil Trade Price

BRc1e52 a / B Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock All £74.00

BRc2c51 Wired Simplified remote controller (without auto swing) All £88.00

KJB111a Recessed Fixing box for BRC2C51 (not required for UK.BRC2C Brass or Chrome Models) All £16.00

UK.BRc2c/chRoMe/PoL BRC2C51 with Polished Chrome Facia without Heat /Cool mode switch All £161.00

UK.BRc2c/chR/PoL/hc BRC2C51 with Polished Chrome Facia with Heat / Cool switch All £167.00

UK.BRc2c/chRoMe/BRU BRC2C51 with Brushed Chrome Facia without Heat / Cool mode switch All £161.00

UK.BRc2c/chR/BRU/hc BRC2C51 with Brushed Chrome Facia with Heat / Cool switch All £167.00

UK.BRc2c/BRass/PoL BRC2C51 with Polished Brass Facia without Heat / Cool mode switch All £161.00

UK.BRc2c/BRa/PoL/hc BRC2C51 with Polished Brass Facia with Heat / Cool switch All £167.00

BRc4c61 Wireless remote controller FXKQ £132.00

BRc4c62 Wireless remote controller FXDQ-M9, FXMQ-MA £132.00

BRc4c65 Wireless remote controller FXDQ-A, FXSQ, FXMQ-P, FXlQ, FXNQ £149.00

BRc7c58 Wireless remote controller FUQ, FXUQ £149.00

BRc7c52 Wireless remote controller FXCQ £149.00

BRc7e618 Wireless remote controller FXAQ £132.00

BRc7F530w Wireless remote controller for White Ceiling Decoration Panel FXZQ-A + BYFQ60CW £149.00

BRc7F530s Wireless remote controller for Silver Ceiling Decoration Panel FXZQ-A + BYFQ60CS £149.00

BRc7Fa532F Wireless remote controller FXFQ-A £149.00

BRc7G53 Wireless remote controller FXHQ £149.00

Page 82: Daikin AC Price List 2013

Integrated Solutions

VRV®

80

VRV® Accessories Control and BMS Interfaces (supplied loose)VRV® control and BMs Interfaces

KRP2a52 KRP4a53 RTD-NeT RTD-10 RTD-ho KLIc-DI DMs504B51 DMs502a51

Interface Method System Unit/Group

Control Protocol - - Modbus Modbus - Modbus KNX loNWorks BACnet

0-10 Volt control 4 4 - - 4 - - - -

Resistance control 4 4 - - 4 - - - -

Control Functions

on/off 4 4 4 4 4 4 4 4 4

SetPoint 4 4 4 4 4 4 4 4 4

operating Mode 4 4 4 4 4 4 4 4 4

Fan Speed 4 4 4 4 4 4 4 4 4

louver Setting - - 4 4 4 4 4 - 4

VAM Damper control - - 4 4 4 - - - -

Control Prohibit / Restrict settings - - 4 4 4 4 - 4 4

Temperature SetPoint limits - - 4 4 - 4 4 - -

Scene Creation - - - - - - 4 - -

Monitoring Functions

on/off 4 4 4 4 - 4 4 4 4

Temperature Set Point - - 4 4 - 4 4 4 4

operating Mode - - 4 4 - 4 4 4 4

Thermostat on - - 4 4 4 4 - - 4

Fan operation - - 4 4 - 4 4 - 4

louvre Position - - 4 4 - 4 4 - 4

Fault 4 4 4 4 4 4 4 4 4

Fault Code - - 4 4 - 4 4 4 4

Remote Controller temperature - - 4 4 - 4 - 4 4

Remote Controller Mode - - 4 4 - 4 - - 4

Number of Units - - 4 4 - 4 - - -

Return Air Temperature (Average/Min/Max) - - 4 4 - 4 - 4 4

Coil in/out temperature - - 4 4 - 4 - - -

Filter Alarm - - 4 4 - 4 4 4 4

Defrost operation - - 4 4 4 4 - - -

Integral Functions (BMS system not req’d)

Temperature Set Back - - - - - 4 - - -

Temperature Setpoint limitation - - - 4 4 4 - - -

Key Card + Window Contact - - - - - 4 - - -

Heating interlock - - - 4 4 - - - -

Run / Standby - - - 4 4 - - - -

Prices

interface KRP2A52 KRP4A53 RTD-NET RTD-10 RTD-Ho KliC-Di DMS504B51 DMS502A51

Trade Price £173.00 £65.00 £161.00 £205.00 Poa £181.00 Poa Poa

associated Items

Mounting Box (FXFQ, FXCQ, FXZQ, FXUQ, FXHQ, FXDQ, FXAQ) UK.FB2 UK.FB2 UK.FB2 UK.FB2 UK.FB2 - - -

Trade Price £24.00 £24.00 £24.00 £24.00 £24.00 - - -

Expansion PCB for additional unit connection - - - - - - - DAM411B51

Trade Price - - - - - - - Poa

Page 83: Daikin AC Price List 2013

Price List 2013 81

VRV®

VRV® Accessories Centralised Control Solutions

Model Description Related Unit Trade Price

Dcs601c51 intelligent touch controller for up to 64 fan coil units All units with F1, F2 wiring connection £1,608.00

KJB411a Recessed Fixing box for i-Touch controller DCS601C51 £67.00

Dcs007a51 HTTP open Protocol Software for i-Touch controller DCS601C51 £917.00

Dcs302a52 Adaptor PCB for external on/off control of i-Touch controller and i-Touch Manager DCS601C51 £101.00

DTa103a51 Adaptor PCB for on/off control of external device from i-Touch controller and i-Touch manager DCS601C51 £299.00

UK.Ic config i-Touch controller - off site configuration charge (please contact your sales office for info/prices) DCS601C51 Poa

Page 84: Daikin AC Price List 2013

Integrated Solutions

VRV®

82

VRV® Accessories Centralised Control Solutions

Model Description Related Unit Trade Price

DcM601a51 i-Touch manager central touch screen controller, with integral web server and email function All units with F1, F2 wiring connection £2,217.00

DcM601a52 i-Touch manager Expansion Module for up to 64 fan coil units and 4 x kWh Meters All units with F1, F2 wiring connection £693.00

DcM601a53 i-Touch manager integrator for single point access for up to 5 individual i-Touch Managers controllers DCM601A51 £2,772.00

DcM002a51 Proportional Power Distribution add-on for i-Touch manager. Provides ability for tenant billing DCM601A51 Poa

DcM008a51 Energy Navigator Software for i-Touch manager. For on screen energy monitoring DCM601A51 Poa

Dcs302a52 Adaptor PCB for external on/off control of i-Touch controller and i-Touch Manager DCS601C51 £101.00

DTa103a51 Adaptor PCB for on/off control of external device from i-Touch controller and i-Touch manager DCS601C51 £299.00

waGo Interface system

Modular interface system for connection to 3rd Party devices such as lights, pumps, PiR sensors, access card readers, etc. Enables the iTM to control external devices and provide customised interlocks for automation and energy saving logic

DCM601A51 Poa

UK.IMaN/coNFIG1 i-Manager off site configuration per FCU DCM601A51 Poa

UK.IMaN/coNFIG2 i-Manager off site configuration & graphical layout per FCU. (Allow 4 weeks from order to delivery) DCM601A51 Poa

UK.Fs1 on site commissioning for PPD or Energy Navigator Software DCM601A51 Poa

UK.IMaN/sITe TRaIN on Site customer training for i Touch Manager System DCM601A51 Poa

Page 85: Daikin AC Price List 2013

Price List 2013 83

VRV®

VRV® Accessories Fan Coil Accessories (supplied loose)

Condensing Unit Accessories (supplied loose)

UK.RAC4

UK.SAF4

Model Description Related Unit Trade Price

BYcQ140cG Roundflow cassette decoration panel with self cleaning filter FXFQ-P £303.00

BYcQ140cw Roundflow cassette decoration panel - white with white louvres FXFQ-P £156.00

BYFQ60cw Fully flat cassette decoration panel in fresh white (N9.5) FXZQ-A £194.00

BYFQ60cs Fully flat cassette decoration panel in silver & white (B471 & N9.5) FXZQ-A £194.00

BYFQ60B2 600 Squ FXZQ-MA style decoration panel in pure white (RAl9010) FXZQ-A £139.00

KDBhQ55B140 Sealing member for air discharge outlet FXFQ-A £88.00

KDDQ55B140 1/2 Fresh air intake kit for up to 20% fresh air (not compatible with self cleaning deco-panel) FXFQ-A, FCQGH, FCQG £440.00

BYBs32D Return air suction grille FXSQ20~32 £109.00

BYBs45D Return air suction grille FXSQ40~50, FBQ35~50 £118.00

BYBs71D Return air suction grille FXSQ63~80, FBQ60~71 £155.00

BYBs125D Return air suction grille FXSQ100~140, FBQ100~140 £194.00

eKBYBsD Mounting Kit for Decoration Panel (when installed directly onto the unit body) FXSQ, FBQ £27.00

UK.Rac1 Return Air Chamber, 1 x 200mm dia FXSQ20-32P £68.00

UK.Rac2 Return Air Chamber, 2 x 200mm dia FXSQ40-50P, FBQ35-50C £77.00

UK.Rac3 Return Air Chamber, 2 x 200mm dia FXSQ63-80P, FBQ60-71C £84.00

UK.Rac3a Return Air Chamber, 3 x 200mm dia FXSQ63-80P, FBQ60-71C £91.00

UK.Rac4 Return Air Chamber, 4 x 200mm dia FXSQ100-125P, FBQ100-140C £113.00

UK.Rac5 Return Air Chamber, 2 x 150mm dia FXDQ20-32A TBc

UK.Rac6 Return Air Chamber, 3 x 150mm dia FXDQ40-50A TBc

UK.Rac7 Return Air Chamber, 4 x 150mm dia FXDQ63A TBc

UK.saF1 Supply Air Flange 1 x 200mm dia FXSQ20-32P £61.00

UK.saF2 Supply Air Flange 2 x 200mm dia FXSQ40-50P, FBQ35-50C £70.00

UK.saF3 Supply Air Flange 2 x 200mm dia FXSQ63-80P, FBQ60-71C £77.00

UK.saF3a Supply Air Flange 3 x 200mm dia FXSQ63-80P, FBQ60-71C £82.00

UK.saF4 Supply Air Flange 4 x 200mm dia FXSQ100-125P, FBQ100-140C £101.00

UK.saF5 Supply Air Flange 2 x 150mm dia FXDQ20-32A £65.00

UK.saF6 Supply Air Flange 3 x 150mm dia FXDQ40-50A £71.00

UK.saF7 Supply Air Flange 4 x 150mm dia FXDQ63A £83.00

UK.FF6P Filter frame and filter FXMQ40 to 80 £98.00

UK.FF7P Filter frame and filter FXMQ100 to 125 £115.00

UK.FF8 Filter frame and filter FXMQ200 to 250 £143.00

KRcs01-4 Remote room mounted temperature sensorFBQ, FCQG, FCQHG, FXFQ-P, FXZQ-A, FXCQ-A, FXUQ-A, FXDQ-A, FXMQ-P, FXSQ-P, FXHQ

£46.00

KRcs01-1 Remote room mounted temperature sensorFAQ, FHQG, FHQ, FFQ, FUQ, FXKQ, FXDQ-M9, FXMQ-MA, FXAQ, FXlQ, FXNQ

£45.00

K.Rss Wireless room mounted temperature sensor and receiver All £91.00

Rs-se Service and Configuration Tool for K.RSS All £87.00

Model Description Related Unit Trade Price

BRP2a81 Adaptor PCB for Heat Cool selection terminals RYYQ £100.00

eKPccaB1 VRV Configurator Software Connection cable. Software available from Daikin Extranet RYYQ £182.00

UK.cGL Condensing Unit Guard Size 100 - 140 - suitable for RXYSQ £437.00

strip & Rebuild of condensing UnitsVRV Condensing Units stripped down for delivery to site where lifting into position is difficult with traditional methods. Units are rebuilt on site by Daikin UK Engineers and fully tested

Poa

Page 86: Daikin AC Price List 2013

Integrated Solutions

VRV®

84

VRV® Refrigerant Leak Detection Systems

Refrigerant leak detection systems can be required for a number of reasons. These tend to fall into two categories.

1) Safety of Building Occupants as required by BS-EN3782) Pollution prevention as detailed under BREEAM recommendations.

These two requirements require different approaches and Daikin UK can provide solutions for both situations.

Refrigerant Leak Detection Alarm 1) The standard BS-EN378 requires that systems containing R410a refrigerant gas such as VRV, meet the requirements regarding maximum system refrigerant volumes that could leak within Hotel Bedroom or other similar Category Class A spaces. If these limitations are exceeded there must be an alarm system installed within each room where this limit is not met. The alarm system must alert the occupier through both audible and visual indication, and must also alert building staff such as supervisors, night porters etc. There is no specific requirement for the alarm system to be linked to the refrigerant system to pump down or stop the operation, although this can be configured if required by the client.

Refrigerant Leak Pump Down System (Heat Recovery Only) 2) To reduce pollution potential through refrigerant leakage in the indoor distribution pipework and fan coil units, a system can be provided for installation on Heat Recovery Systems. The system comprises a set of motorised isolation ball valves controlled through a central control panel that will instigate a refrigerant pump down process, shut the isolation valves on main pipe line, and shut down the system on completion. The control panel will activate this function followinggenerationofafaultcodefromtheVRV®systemindicatingalossofrefrigerant.ThissystemmaybeconsideredassuitableforBREEAMcreditssubjectto evaluation by the individual BREEAM assessor.

It is recommended that guidance on the selection and installation of these systems is obtained from your local Daikin UK sales office.

ExampleofSystemComponentsrequiredforaHeatRecoveryOutdoorUnit–REYQ14P1 x UK.MBVPAN £1,141.00 1 x 826.MBV01 £440.00 1 x 826.MBV06 £396.00 1 x 826.MBV08 £579.00 system Total £2,556.00

Model Description Related Unit Trade Price

UK.MBVPaN Central Control Panel providing automated refrigerant pump down and isolation of condensing unit via motorised ball valves, (price excludes valves, see below)

REYQ, REMQ, REYAQ

£1,141.00

UK.IaMc Alarm buzzer and lamp panel for mounting in a central building supervisor location. For connection to UK.MBVPAN £388.00

826.MBV01 3/8 + 1/2 Motorised Ball Valve c/w Aux Switch - liquid £440.00 826.MBV02 5/8 Motorised Ball Valve c/w Aux Switch - liquid £446.00 826.MBV03 3/4 Motorised Ball Valve c/w Aux Switch - liquid £458.00 826.MBV04 7/8 Motorised Ball Valve c/w Aux Switch - liquid £458.00 826.MBV05 5/8 Motorised Ball Valve - Gas £385.00 826.MBV06 3/4 Motorised Ball Valve - Gas £396.00 826.MBV07 7/8 Motorised Ball Valve - Gas £396.00 826.MBV08 1 1/8 Motorised Ball Valve - Gas £579.00 826.MBV09 1 3/8 Motorised Ball Valve - Gas £772.00 826.MBV10 1 5/8 Motorised Ball Valve - Gas £802.00

Model Description Related Unit Trade Price

UK.IaM1

Room based refrigerant gas detector with remote room mounted stainless steel facia plate. Provides local audible and visual alarm notification. Terminals for connection to alarm network and optional connection to VRV® Fan coil to force system shut down

All £279.00

UK.IaM2Network alarm hub for connection of up to 16 room alarms. Hub can be connected in a pyramid formation of 16 groups back to a single unit for connection to a central alarm indicator panel (UK.iAMC)

All £550.00

UK.IaMc Alarm buzzer and lamp panel for mounting in a central building supervisor location All £388.00

Page 87: Daikin AC Price List 2013

Price List 2013 85

VRV®

Extend product lifetimeThe DNSS is designed to make sure that your equipment is maintained and running as efficiently as possible. This optimisation will extend the lifespan of your equipment.

Malfunction messagesIn the unlikely event of a problem occurring, your regional Daikin UK office will contact you directly. Our engineers, who are dedicated to your installation, will inform you regarding the nature of the problem and will help you towards the next step of solving the problem.

Prevent product malfunctionsThe DNSS will analyse the data from your equipment every minute of the day and will alert us before the equipment actually breaks down. In this way, failures can be prevented and possible down time reduced to an absolute minimum.

Remote diagnosticsThe DNSS continuously checks the cleanliness of the system filters and heat exchanger. Furthermore, the DNSS manages a wide range of data (pressures, temperatures, running hours, etc.) in order to let your equipment run as efficiently and trouble free as possible. This will also prevent your equipment from using too much energy.

energy

savings up to

25%unique

innovation by

daikin

DNSS EcoSave

Your installation under continuous monitoring

• 24/7, 365 days a year remote monitoring

• Predictive maintenance

• Improved reliability

• Improved comfort levels

• Helps increase efficiency

• Helps reduce maintenance costs

• Extends product lifetime

Extra value at low cost

• A strategy of preventing breakdowns and limiting unnecessary maintenance visits

• Efficiently organising site interventions by diagnosing the nature and the extent of the problem before going to site

• Innovative technology that helps to optimise your equipment’s potential

• Ensures the most comfortable environment in your premises

The DNSS is a remote monitoring system, which will allow you to continuously optimise the running of your Daikin equipment; control your energy consumption (so reduce your Carbon Footprint), extend the life span of your equipment and reduce operational costs.

What is the Daikin Network Service System (DNSS)?

Page 88: Daikin AC Price List 2013

VRV®

86

Page 89: Daikin AC Price List 2013

87

Vent

ilatio

n

scotland Region

0845 641 9330

Northern Region

0845 641 9340

Midlands Region

0845 641 9370

western Region

0845 641 9320

North London

0845 641 9360

south London

0845 641 9355

VentilationVAM / VKM 88

Page 90: Daikin AC Price List 2013

Integrated Solutions

Vent

ilatio

n

88

With the advent of new building regulations, greater awareness of increasing energy costs and a responsibility towards environmental issues, modern commercial spaces are insulated better than ever.

Ventilation

Double glazing, thicker insulation and draught exclusion of course, help considerably towards reducing heating/cooling demand and burdens on the environment.

The down-side however, is that these same commercial spaces have now become, in effect, sealed boxes with little or no replenishment of the air.

Daikin offers a variety of solutions for the provision of fresh air ventilation to offices, hotels, stores and other commercial outlets.

Heat Reclaim VentilationProper ventilation is a key component of climate control in buildings, offices and shops. In its basic function, it ensures a flow of incoming fresh air and outgoing stale air. Our HRV (heat reclaim ventilation) solution can do much more. It can recover heat and OPTIMISE THE BALANCE BETWEEN INDOOR AND OUTDOOR TEMPERATURE AND HUMIDITY, thus reducing the load on the system and increasing efficiency.

accessory Ref Description Trade PriceBRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock £74.00 KRP2A52/UK.FB2 System adaptor PCB for remote on/off, status indication and temperature setting £197.00 RTD-Net/UK.FB2 Modbus interface PCB for Sky Air and VRV £185.00 RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV. Poa

Accessories: Notes:i) Please contact your local sales office

for required options when combined operation with an air conditioning system is required

ii) optional silencers, high efficiency filters etc are available. Prices and details on request

iii) VKM models must be connected as the slave indoor unit of a standard VRV indoor unit and share the same BRC1D52 remote controller and BSVQ unit (if connected to Heat Recovery)

Total Heat ExchangerVAM / VKM

VaM150Fa VaM250Fa VaM350FB VaM500FB VaM650FB VaM800FB VaM1000FB VaM1500FB VaM2000FB VKM50G VKM80G VKM100GDimensions Height mm 285 301 364 726 387

Width mm 776 828 1004 1514 1764Depth mm 525 816 868 1156 868 1156 832 1214

Weight kg 24 33 52 64 131 152 96 109 114Duct Connections mm 100Ø 150Ø 150Ø 200Ø 200Ø 250Ø 250Ø 350Ø 350Ø 200Ø 250Ø 250ØAir Flow Rate Ultra-High m3/hr 150 250 350 500 650 800 1000 1500 2000 500 750 950

High m3/hr 150 250 350 500 650 800 1000 1500 2000 500 750 950low m3/hr 110 155 230 350 500 670 870 1200 1400 440 640 820

External Static Pressure

Ultra-High Pa 69 64 98 98 93 137 157 137 137 180 170 150High Pa 39 39 150 120 100low Pa 20 20 110 80 70

Sound Pressure level (Heat Exchange Mode)

Ultra-High dBA 28.5 29.0 32.0 33.0 34.5 36.0 36.0 39.5 40.0 39.0 41.5 41.0High dBA 27.5 27.0 31.5 31.5 33.0 34.5 35.0 38.0 38.0 37.0 39.0 39.0low dBA 21.5 22.0 23.5 24.5 27.0 31.0 31.0 34.0 35.0 35.5 37.0 36.5

Electrical Details Power Supply V 230Hz 50Phase 1

Running Current A 0.9 0.9 0.9 1.3 1.6 2.5 3.0 5.0 5.0 3.8 3.8 3.8Max Fuse Size A 15 15 15 15 15 15 15 15 15 15 15 15

Trade Unit Price £422.00 £504.00 £668.00 £855.00 £1,046.00 £1,232.00 £1,413.00 £2,158.00 £2,815.00 £2,048.00 £2,486.00 £2,957.00

Page 91: Daikin AC Price List 2013

89

Com

mer

cial

Hea

ting

scotland Region

0845 641 9330

Northern Region

0845 641 9340

Midlands Region

0845 641 9370

western Region

0845 641 9320

North London

0845 641 9360

south London

0845 641 9355

Commercial HeatingAltherma Flex Product Overview 90

Altherma Flex De-centralised 91

Altherma Flex Centralised 92

Page 92: Daikin AC Price List 2013

Integrated Solutions

Com

mer

cial

Hea

ting

90

The Daikin Altherma Flex heat pump series is ideal for apartment buildings and community heating, providing efficient air-to water heat pump technology for large residential and commercial buildings.

The Daikin Altherma Flex heat pump series

The product can be configured either as a de-centralised or a centralised system:

De-centralised systemThe hydroboxes can be located in individual dwellings, such as apartments or collective housing, to create a de-centralised system. Each indoor unit can be operated independently, providing each property with individual control of heating, hotwater(coolingoptionalon50&80classunits).

The indoor hydrobox units are fully equipped with all the required hydraulic components, so they can be connected easily to the heat distribution system. Individual dwellings can also be equipped with separate domestic hot water tanks, which are designed to stack on top of the indoor units.

Centralised systemAlternatively, the indoor units can be located together in one central plant area to create a centralised system suitable for a wide range of commercial and large domestic applications.

The centralised indoor units offer modular system scalability and capacity to meet the heating demand of the overall building.

Page 93: Daikin AC Price List 2013

Price List 2013 91

Com

mer

cial

Hea

ting

Indoor Units (hydrobox) eKhVMRD50a eKhVMRD80a eKhVMYD50a eKhVMYD80aFunction Heating & Hot water Heating, hot water & coolingHeating Capacity kW 5.6 9 5.6 9Cooling capacity kW n/a 5 8Capacity index 50 80 50 80Dimensions HxWxD mm 705 x 600 x 695Empty Weight kg 92 120leaving Water Temperature Range heating °C 25~80 leaving Water Temperature Range cooling °C n/a 5~20Drain valve Yes Water Pump Nominal ESP Heating kPa 83.7 58.8Expansion Vessel 7 litres heating 7 litres heating, 2 litres coolingMaterial Precoated sheet metalColour Metalic GreyElectrical Details Power Supply 230V 1ph 50Hz

Starting current amps 4Nominal running Current* amps 6.5 10.9 6.5 10.9Maximum running current amps 16.5Fuse Rating amps 20

Refrigerant Pipe Sizes mm 12.7 Gas, 9.52 liquid 12.7 Gas, 9.52 liquid, 15.9 SuctionWater Side Pipe Sizes 1" FemaleSound Pressure level dBA 40 42 40 42Refrigerant R134a Cascade

Trade Unit Price hydro Box £2,479.00 £2,560.00 £3,045.00 £3,135.00

*Nominalrunningcurrentstatedat-3°Cambientairtemperature&75°Cleavingwatertemperature100%connectionratio

Domestic hot water cylinder eKhTsU200ac eKhTsU260acType Unvented System (includes EKUHWHT unvented Kit) Water Volume l 200 260Max Water Temperature °C 75Height mm 1335 1610Width mm 600Depth mm 695Empty Weight kg 70 78Colour Metallic greyMaterial inside Tank Stainless SteelMaterial outside Casing Precoated sheet metalPiping Connections All inch 3/4 "insulation mm 80Heat loss / 24hour dt 45°C 1.2 1.5Heat exchanger surface area m2 1.56

Trade Unit Price £1,113.00 £1,261.00

Altherma Flex Communal Heat Pump De-centralisedDaikin Altherma Flex type is the first heating system for apartments and collective housing that fully incorporates the use of renewable energy sources, making large residential buildings more environmentally sustainable by reducing primary energy usage – thus delivering lower running costs and CO

2 emissions.

outdoor Units eMRQ8a eMRQ10a eMRQ12a eMRQ14a eMRQ16aCapacity Nominal Heating kW 22.4 28.0 33.6 39.2 44.8Dimensions Height x Width x Depth mm 1680 x 1300 x 765Weight kg 331 339Air Flow Rate m3/min 190 190 210 235 240External Static Pressure High Pa 78.4 78.4 78.4 78.4 78.4Electrical Details Power Supply 400 V 3ph 50 Hz

Starting current amps 74 74 75 4 4Nominal running Current* amps 7.6 9.9 12.6 14.0 16.9Maximum running current amps 17.1 22.1 22.3 32.8 33.0Fuse Rating amps 20 25 25 40 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 10.3 10.6 10.8 11.1 11.1Additional Charge kg Refer to Databook

Sound Pressure dBA 58 58 60 62 63Piping limits Maximum length m 100

Maximum Vertical Rise m 40Piping Connections liquid mm 9.52 9.52 12.7 12.7 12.7

Discharge mm 15.9 19.1 19.1 22.2 22.2Gas mm 19.1 22.2 28.6 28.6 28.6

Capacity index limit 100~260 125~325 150~390 175~455 200~520Maximum Number of Connected indoor Units 5 6 7 9 10

Trade condensing Unit Price £4,765.00 £5,000.00 £5,773.00 £6,806.00 £8,021.00

*Nominalrunningcurrentstatedat-3°Cambientairtemperature&75°Cleavingwatertemperature100%connectionratio

Altherma Flex Outdoor Units EMRQ

Altherma Flex Indoor Units EKHVMRD/EKHVMYD

Hot Water Cylinders EKHTSU Accessories

Notes:i) Refnet joint prices can be found on page 78ii) Commissioning assistance should be included for each hydroboxiii) DHW cylinder required for hot water function

accessories for hydrobox Description Trade priceEKRP1AHT optional PCB for demand control £104.00EKRP1HBA optional PCB for remote alarm monitoring £104.00RTD-W MoDBUS interface for HT hydrobox £205.00UK.FB2 Fixing box for RTD-W £24.00EKCC-W Sequence controller £640.00EKClWS Additional thermistor for sequence controller £73.00EKRUAHTB Remote user interface £157.00EKBUHA6V3 in line back up heater 6kW, 1-phase, 230V £461.00EKBUHA6W1 in line back up heater 6kW, 3-phase, 400V £461.00EKFMAHTB Kit for standalone installation with floor

standing hydrobox£277.00

UK.FSHEAT/CoMMS Commissioning assistance per hydrobox 1 to 10 hydroboxes

£240.00

Commissioning assistance per hydrobox 11 to 20 hydroboxes

£216.00

Commissioning assistance per hydrobox >20 hydroboxes

£192.00

Hydrobox&cylindershown in

combination

Page 94: Daikin AC Price List 2013

Integrated Solutions

Com

mer

cial

Hea

ting

92

Altherma Flex Communal Heat Pump CentralisedDaikin Altherma Flex type is the first centralised heating system for schools, public buildings , hotels,gyms&apartmentsthatfullyincorporatestheuseofrenewableenergysources,makinglarge buildings more environmentally sustainable by reducing primary energy usage – thus delivering lower running costs and CO

2 emissions.

Altherma Flex Indoor Units EKHBRD

Pre Selected Combinations

Indoor unit (hydrobox) eKhBRD 011acV1

eKhBRD 014acV1

eKhBRD 016acV1

eKhBRD 011acY1

eKhBRD 014acY1

eKhBRD 016acY1

Function Heating & Hot waterHeating Capacity kW 11 14 16 11 14 16Cooling capacity kW n/aCapacity index 100 125 140 100 125 140Dimensions HxWxD mm 705 x 600 x 695Empty Weight kg 145 148leaving Water Temperature Range heating °C 25~80Drain valve Yes Water Pump 92 88 85 92 88 85Expansion Vessel 12 litresMaterial Precoated sheet metalColour Metalic GreyElectrical Details Power Supply 230V 1ph 400V 3ph

Starting current amps 4 4Nominal running Current* amps 11.6 15.1 18.1 4.3 5.6 6.7Maximum running current amps 22.5 23.8 23.8 12.5 12.5 12.5Fuse Rating amps 25 16

Refrigerant Pipe Sizes mm 15.9 Gas, 9.52 liquidWater Side Pipe Sizes 1” FemaleSound Pressure level dBA 43 45 46 43 45 46Refrigerant R134a Cascade

Trade Unit Price hydro Box £2,985.00 £3,038.00 £3,130.00 £3,045.00 £3,099.00 £3,192.00

*Nominalrunningcurrentstatedat-3°Cambientairtemperature&75°Cleavingwatertemperature100%connectionratio

heating capacity (1) a7w35 kw 28.0 31.4 42.0 47.0heating capacity (2) a-3w65 kw 23.9 26.7 34.3 38.7outdoor unit 1 x EMRQ8 £4,765 1 x EMRQ10 £5,000 1 x EMRQ12 £5,773 1 x EMRQ14 £6,806Hydroboxes 2 x EKHBRD014ACV1 £6,076 2 x EKHBRD016ACV1 £6,260 3 x EKHBRD014ACV1 £9,114 3 x EKHBRD016ACV1 £9,390Demand PCBs 2 x EKRP1AHT £208 2 x EKRP1AHT £208 3 x EKRP1AHT £312 3 x EKRP1AHT £312Refnets 1 x KHRQM29T9 £35 1 x KHRQM29T9 £35 1 x KHRQM64H £136 1 x KHRQM64H £136

Trade price £11,084.00 £11,503.00 £15,335.00 £16,644.00

(1) Heating ambient air temperature 7°C and leaving water temperature 35°C(2) Heating ambient air temperature -3°C and leaving water temperature 65°C, capacity stated net of 1 defrost cycle per hour

Notes:i) Refnet joints can be found on page 78ii) Commissioning assistance should be included per hydroboxiii) DHW cylinder required for hot water functioniv) See page 91 for accessories

outdoor Units eMRQ8a eMRQ10a eMRQ12a eMRQ14a eMRQ16aCapacity Nominal Heating kW 22.4 28.0 33.6 39.2 44.8Dimensions Height x Width x Depth mm 1680 x 1300 x 765Weight kg 331 339Air Flow Rate m3/min 190 190 210 235 240External Static Pressure High Pa 78.4 78.4 78.4 78.4 78.4Electrical Details Power Supply 400 V 3ph 50 Hz

Starting current amps 74 74 75 4 4Nominal running Current* amps 7.6 9.9 12.6 14.0 16.9Maximum running current amps 17.1 22.1 22.3 32.8 33.0Fuse Rating amps 20 25 25 40 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 10.3 10.6 10.8 11.1 11.1Additional Charge kg Refer to Databook

Sound Pressure dBA 58 58 60 62 63Piping limits Maximum length m 100

Maximum Vertical Rise m 40Piping Connections liquid mm 9.52 9.52 12.7 12.7 12.7

Discharge mm 15.9 19.1 19.1 22.2 22.2Gas mm 19.1 22.2 28.6 28.6 28.6

Capacity index limit 100~260 125~325 150~390 175~455 200~520Maximum Number of Connected indoor Units 5 6 7 9 10

Trade condensing Unit Price £4,765.00 £5,000.00 £5,773.00 £6,806.00 £8,021.00

*Nominalrunningcurrentstatedat-3°Cambientairtemperature&75°Cleavingwatertemperature100%connectionratio

Altherma Flex Outdoor Units EMRQ

Page 95: Daikin AC Price List 2013

93

Refr

iger

atio

n

scotland Region

0845 641 9330

Northern Region

0845 641 9340

Midlands Region

0845 641 9370

western Region

0845 641 9320

North London

0845 641 9360

south London

0845 641 9355

RefrigerationCVP 94

ZEAS 95

Page 96: Daikin AC Price List 2013

Integrated Solutions

Refr

iger

atio

n

94

CVP is a compact, low noise system which integrates high and low temperature refrigeration along with heating and cooling into one system. A total solution helping retailers save energy and the environment.

CVP

Contact your local sales office for more information.

Benefits• Optimum efficiency: inverter driven outdoor units match

system output to the actual demand in order to reach optimum efficiency under all conditions

• Various options: supports a wide range of refrigeration and cooling units

• Save energy: by recovering the heat extracted from the connected refrigeration appliances and using sophisticated controls, energy savings of up to 50% can be reached

• Small footprint: along with reduced piping the small CVP is ideal for densely populated urban areas

• Flexible:VRV®(VariableRefrigerantVolume)technologyforflexibleapplicationrange.FullrangeofVRV®fancoilsavailabletogether with air curtains

• Minimal noise: low operating sound level

Indoor units LRYeQ16aY1Casing Colour ivory white (Munsell code: 5Y7.5/1)Dimensions HeightxWidthx Depth mm 1,680x1,240x765Weight kg 370Heat exchanger Type Cross fin coilFan Type Propeller fan

Quantity 2Air flow rate Cooling Nom. m³/min 230

Fan motor output W 750Drive Direct drive

Compressor N° of compressors 3Type Hermetically sealed scroll compressorPiston displacement m³/h 13.34 / 10.53 / 10.53Speed rpm 6,300 / 2,900 / 2,900output W 2,500 / 3,600 / 4,500Starting method Direct on line (inverter driven)Frequency oN/oFF less than 6 times/hour

operation range Evaporator Cooling Min.~Max. °CDB -20 @ 0~10Refrigerant Type R-410A

Charge kg 11.5Control Electronic expansion valve

Refrigerant oil Type Daphne FVC68DCharged volume l 1.7 (1)

2.1 (2) 2.1 (3) 4.0 (4)

Power supply Phase / Frequency / Voltage Hz / V 3~ / 50 / 380-415Voltage range Min. % -10

Max. % 10

Trade price £13,740.00

CVPLRYEQ-AY1

HEATRECOVERY

-10°C

-35°C

(1) Compressor 1 | (2) Compressor 2 | (3) Compressor 3 | (4) Factory charge of unit

Refer to your local sales office for further details and prices

Page 97: Daikin AC Price List 2013

Price List 2013 95

Refr

iger

atio

n

Compact yet powerful and extremely energy efficient, Daikin ZEAS condensing units offer an industry-leading solution for all kinds of installation projects.

ZEAS is an adaptable and controllable solution for all kinds of environments with fluctuating loads such as supermarkets, hotels, restaurants, hospitals and florists, as well as food production facilities such as cold storage, and blast coolers and freezers.

Delivering all the benefits of inverter controlled VRV technology for commercial refrigeration systems, ZEAS offers a comprehensive product range suitable for low temperature applications of 5.4 to 15.1 kW at -35/+32°C and medium temperature applications of 12.2 to 37.0 kW at -10°C /+32°C.

Its small footprint and low sound levels offer installation flexibility, so you can gain larger capacities even in small spaces. What’s more, the ZEAS solution comes fully packaged and programmed, with minimal pipe work required, so installation time and cost is reduced. Plus you can depend on Daikin’s dedicated after-sales support to help ensure that commissioning and maintenance go without a hitch.

Zeas condensing units: a complete solution for refrigeration applicationsWhen you select a refrigeration condensing unit, you want premium performance with simple installation and maintenance. That’s why you should specify Daikin ZEAS condensing units.

All in all, it’s a quality solution that delivers maximum refrigeration capacity with minimal fuss.

Zeas condensing units offer:

• Compact system with reduced piping lengths

• Higher refrigeration capacity to power consumption ratio compared with standard systems

• COP of up to 3.0

• Energy efficient inverter control minimises CO2 emissions

• Utilises energy efficient R-410A refrigerant

To find out more about ZEAS, please visit www.daikin.co.uk, email [email protected] or contact your local sales branch office.

outdoor unit LReQ5BY1 LReQ6BY1 LReQ8BY1 LReQ10BY1 LReQ12BY1 LReQ15BY1 LReQ20BY1Cooling capacity* Nom. kW 12.5 15.2 19.8 23.8 26.5 33.9 37.9Dimensions Unit H xW xD mm 1,680x635x765 1,680x930x765 1,680x1,240x765Weight Unit kg 166 242 331 337Heat exchanger Type Cross fin coilFan Type Propeller fan

Quantity 1 2Air flow rate Cooling Nom. m³/min 95 102 171 179 191 230 240

Fan motor output kW 0.35 0.75 0.35 + 0.35 0.75+0.75Drive Direct drive

Compressor Type Hermetically sealed scroll compressor Hermetically sealed scroll compressor (x2)Piston displacement m³/h 11.18 13.85 19.68 23.36 25.27 32.24 35.8Speed rpm 5,280 6,540 4,320+2,900 6,060+2,900 6,960+2,900 5,280+2,900+2,900 6,960+2,900+2,900output kW 2.6 3.2 2.1 + 3.6 3.0 + 3.6 3.4 + 3.6 2.6 + 3.6 + 3.6 3.4 + 3.6 + 3.6Starting method Direct on line (inverter driven) Direct on line (inverter driven) (x2)

operation range Evaporator Min.~Max. °CDB -45~10Ambient temp. Min.~Max. °C -20~43

Refrigerant Type R-410ACharge kg 5.2 7.9 11.5Control Electronic expansion valve

Refrigerant oil Type Daphne FVC68DCharged volume l 1.7 / 2.5 1.7 / 2.5 1.7 / 2.1 / 3.0 1.7 / 2.1 / 3.0 1.7 / 2.1 / 3.0 1.7 / 2.1 / 4.0 1.7 / 2.1 / 4.0

Piping connections

liquid 50m or less ø 9.5 C1220T (Brazing connection) ø 12.7 C1220T (Brazing connection)50~130m ø 9.5 C1220T (Brazing connection) ø 12.7 C1220T (Brazing connection)

Gas ø 22.2 C1220T (Brazing connection) ø 28.6 C1220T (Brazing connection) ø 34.9 C1220T (Brazing connection)Power supply Phase/Frequency/Voltage Hz/V 3~/50/380-415Voltage range Min. % -10

Max. % 10Current Nominal running

current (RlA) - 50HzCompressor Cooling A 7.1 9.2 5.3 + 7.5 7.4 + 7.9 9.8 + 8.3 7.0 + 8.2

+ 8.29.5 + 8.4

+ 8.4

Current - 50Hz Starting current (MSC) A - 74 75 84Minimum Ssc value kVa - 655 899 1,097 761 945Minimum circuit amps (MCA) A 12.8 13.7 19.3 22.0 24.0 31.4 35.0Maximum fuse amps (MFA) A 15 25 40Total overcurrent amps (ToCA) A 15.6 31.5 48.3Full load amps (FlA) Fan motor A 0.4 0.9 0.4 + 0.4 0.7 + 0.7

Trade price £6,966.00 £7,872.00 £8,681.00 £9,887.00 £11,343.00 £14,960.00 £16,982.00

*operation conditions of outdoor unit: Te = -10°C, outdoor temperature +32°C, suction SH10°C

Page 98: Daikin AC Price List 2013

Refr

iger

atio

n

96

Page 99: Daikin AC Price List 2013

97

App

lied

scotland Region

0845 641 9330

Northern Region

0845 641 9340

Midlands Region

0845 641 9370

western Region

0845 641 9320

North London

0845 641 9360

south London

0845 641 9355

AppliedWater Chillers 98

Chilled Water Fan Coils 102

Page 100: Daikin AC Price List 2013

Integrated Solutions

App

lied

98

Air Cooled Water Chillers

ModelNo

Nominal coolingkw

Nominalheatingkw

Powersupply

TradePrice

air cooled Inverter Packaged swing / scroll compressor – R410a

ewaQ005aDVP 5.20 - 1-phase £2,020.00ewaQ006aDVP 6.00 - 1-phase £2,214.00ewaQ007aDVP 7.10 - 1-phase £2,453.00ewaQ009acV3P 8.60 - 1-phase £2,800.00ewaQ010acV3P 9.60 - 1-phase £2,963.00ewaQ011acV3P 11.10 - 1-phase £3,185.00ewaQ009acw1P 9.10 - 3-phase £2,921.00ewaQ011acw1P 11.10 - 3-phase £3,211.00ewaQ013acw1P 13.30 - 3-phase £3,402.00

air cooled Inverter Packaged scroll compressor – R410a

ewaQ016BawN 17.4 - 3 - phase £6,137.00ewaQ021BawN 21.7 - 3 - phase £5,441.00ewaQ025BawN 25.8 - 3 - phase £6,137.00ewaQ032BawN 32.3 - 3 - phase £7,081.00ewaQ040BawN 43.4 - 3 - phase £9,364.00ewaQ050BawN 51.8 - 3 - phase £10,434.00ewaQ064BawN 64.5 - 3 - phase £12,049.00

air cooled packaged scroll compressor – R407c

eUwaN5KBZw 11.30 - 3-phase £2,377.00eUwaN8KBZw 17.90 - 3-phase £3,527.00eUwaN10KBZw 22.50 - 3-phase £3,989.00eUwaN12KBZw 26.50 - 3-phase £4,194.00eUwaN16KBZw 34.60 - 3-phase £5,583.00eUwaN20KBZw 46.60 - 3-phase £7,058.00eUwaN24KBZw 55.30 - 3-phase £7,860.00

Cooling Capacity:

Notes:i) Please contact your local sales office for further information on

these products

ii) Nominal cooling capacities are based on 35°C ambient, chilled water @ 12/7°C

iii) EWAQ -A series only operates in cooling down to ambients of +10°C

iv) The EWAQ064BA delivery does not include offloading to kerbside. Additional costs for delivery with a Hi-ab are available on request

air cooled Packaged scroll compressor – R407c c/w hydraulic pump and expansion vessel

eUwaP5KBZw 11.30 - 3-phase £2,740.00eUwaP8KBZw 17.90 - 3-phase £3,980.00eUwaP10KBZw 22.50 - 3-phase £4,473.00eUwaP12KBZw 26.50 - 3-phase £4,683.00eUwaP16KBZw 34.60 - 3-phase £5,992.00eUwaP20KBZw 46.60 - 3-phase £7,540.00eUwaP24KBZw 55.30 - 3-phase £8,364.00

air cooled Packaged scroll compressor – R407c c/w hydraulic pump, expansion vessel and buffer tank

eUwaB5KBZw 11.30 - 3-phase £2,994.00eUwaB8KBZw 17.90 - 3-phase £4,292.00eUwaB10KBZw 22.50 - 3-phase £4,807.00eUwaB12KBZw 26.50 - 3-phase £5,025.00eUwaB16KBZw 34.60 - 3-phase £6,266.00eUwaB20KBZw 46.60 - 3-phase £7,860.00eUwaB24KBZw 55.30 - 3-phase £8,701.00

To Fit Model ewaQ-a ewaQ-aDVP ewaQ-acV3P ewaQ-acw1PPart No Description 005 006 007 009 010 011 009 011 013oP10 Evaporator Heater Tape £270 £270 £270 £298 £298 £298 £298 £298 £298oPHP High Static Pump Na Na Na £149 £149 £149 £149 £149 £149

To Fit Model ewaQ-BaPart No Description 016 021 025 032 040 050 064UK57-BA Evaporator Heater Tape £386 £386 £386 £386 £486 £486 £486UK08B-BA Chilled Water Down to -10 £286 £286 £286 £286 £386 £386 £386UK78-BA low lift Pump £429 £429 £429 £572 £572 £572 £572UK79-BA High lift Pump £629 £629 £629 £629 £857 £857 £857

To Fit Model eUwaN-KBZwPart No Description 5 8 10 12 16 20 24oP10 Evaporator Heater Tape £109 £109 £109 £109 £109 £109 £109oPHF High Static Fan £16 £38 £38 £38 £78 £78 £78oPZH Chilled Water Down to -5 £163 £163 £163 £163 £163 £163 £163oPZl Chilled Water Down to -10 £163 £163 £163 £163 £163 £163 £163

To Fit Model eUwaP-KBZwPart No Description 5 8 10 12 16 20 24oP10 Evaporator Heater Tape £220 £220 £220 £220 £220 £220 £220oPHP High Static Pump £67 £67 £67 £67 £256 £256 £256oPHF High Static Fan £16 £38 £38 £38 £78 £78 £78oPZH Chilled Water Down to -5 £163 £163 £163 £163 £163 £163 £163oPZl Chilled Water Down to -10 £163 £163 £163 £163 £163 £163 £163

To Fit Model eUwaB-KBZwPart No Description 5 8 10 12 16 20 24oP10 Evaporator Heater Tape £270 £270 £270 £270 £270 £270 £270oPHP High Static Pump £67 £67 £67 £67 £256 £256 £256oPHF High Static Fan £16 £38 £38 £38 £78 £78 £78oPZH Chilled Water Down to -5 £163 £163 £163 £163 £163 £163 £163oPZl Chilled Water Down to -10 £163 £163 £163 £163 £163 £163 £163

Fitted Options:

Page 101: Daikin AC Price List 2013

Price List 2013 99

App

lied

Air Cooled Heat Pump Water Chillers

air cooled heat Pump Inverter Packaged swing / scroll compressor – R410a

ewYQ005aDVP 5.20 5.65 1-phase £2,333.00ewYQ006aDVP 6.00 6.35 1-phase £2,520.00ewYQ007aDVP 7.10 7.75 1-phase £2,789.00ewYQ009acV3P 8.60 9.90 1-phase £3,223.00ewYQ010acV3P 9.60 11.40 1-phase £3,348.00ewYQ011acV3P 11.10 12.90 1-phase £3,392.00ewYQ009acw1P 9.10 10.90 3-phase £3,348.00ewYQ011acw1P 11.10 12.40 3-phase £3,633.00ewYQ013acw1P 13.30 13.90 3-phase £3,840.00

air cooled heat Pump Inverter Packaged scroll compressor – R410a

ewYQ016BawN 17.4 16.2 3-phase £5,314.00ewYQ021BawN 21.7 20.3 3-phase £6,259.00ewYQ025BawN 25.8 24.6 3-phase £7,060.00ewYQ032BawN 32.3 30.7 3-phase £8,142.00ewYQ040BawN 43.4 40.6 3-phase £10,769.00ewYQ050BawN 51.8 49.0 3-phase £11,997.00ewYQ064BawN 64.5 61.5 3-phase £13,857.00

air cooled heat Pump Packaged scroll compressor – R407c

eUwYN5KBZw 9.10 11.90 3-phase £2,663.00eUwYN8KBZw 17.10 18.50 3-phase £4,099.00eUwYN10KBZw 21.00 24.00 3-phase £4,494.00eUwYN12KBZw 25.00 27.00 3-phase £4,764.00eUwYN16KBZw 34.20 37.00 3-phase £6,440.00eUwYN20KBZw 40.00 46.00 3-phase £7,809.00eUwYN24KBZw 50.00 54.00 3-phase £8,605.00

Cooling Capacity:ModelNo

Nominal coolingkw

Nominalheatingkw

Powersupply

TradePrice

Notes:i) Please contact your local sales office for further information on

these products

ii) Nominal cooling capacities are based on 35°C ambient, chilled water @ 12/7°C

iii) Nominal heating capacities are based on 7°C db / 6°C wb ambient, water @ 45 / 50°C

iv) EWYQ -A series only operates in cooling down to ambients of +10°C

v) The EWYQ064BA delivery does not include offloading to kerbside. Additional costs for delivery with a Hi-ab are available on request

air cooled heat Pump Packaged scroll compressor – R407c c/w hydraulic pump and expansion vessel

eUwYP5KBZw 9.10 11.90 3-phase £3,033.00eUwYP8KBZw 17.10 18.50 3-phase £4,579.00eUwYP10KBZw 21.00 24.00 3-phase £4,989.00eUwYP12KBZw 25.00 27.00 3-phase £5,273.00eUwYP16KBZw 34.20 37.00 3-phase £6,867.00eUwYP20KBZw 40.00 46.00 3-phase £8,300.00eUwYP24KBZw 50.00 54.00 3-phase £9,108.00

air cooled heat Pump Packaged scroll compressor – R407c c/w hydraulic pump, expansion vessel and buffer tank

eUwYB5KBZw 9.10 11.90 3-phase £3,288.00eUwYB8KBZw 17.10 18.50 3-phase £4,714.00eUwYB10KBZw 21.00 24.00 3-phase £5,276.00eUwYB12KBZw 25.00 27.00 3-phase £5,514.00eUwYB16KBZw 34.20 37.00 3-phase £6,883.00eUwYB20KBZw 40.00 46.00 3-phase £8,629.00eUwYB24KBZw 50.00 54.00 3-phase £9,557.00

To Fit Model ewYQ-a ewYQ-aDVP ewYQ-acV3P ewYQ-acw1PPart No Description 005 006 007 009 010 011 009 011 013oP10 Evaporator Heater Tape £270 £270 £270 £298 £298 £298 £298 £298 £298oPHP High Static Pump Na Na Na £149 £149 £149 £149 £149 £149

To Fit Model ewYQ-BaPart No Description 016 021 025 032 040 050 064UK57-BA Evaporator Heater Tape £386 £386 £386 £386 £486 £486 £486UK08B-BA Chilled Water Down to -10 £286 £286 £286 £286 £386 £386 £386UK78-BA low lift Pump £429 £429 £429 £572 £572 £572 £572UK79-BA High lift Pump £629 £629 £629 £629 £857 £857 £857

To Fit Model eUwYN-KBZwPart No Description 5 8 10 12 16 20 24oP10 Evaporator Heater Tape £109 £109 £109 £109 £109 £109 £109oPHF High Static Fan £16 £38 £38 £38 £78 £78 £78oPZH Chilled Water Down to -5 £163 £163 £163 £163 £163 £163 £163oPZl Chilled Water Down to -10 £163 £163 £163 £163 £163 £163 £163

To Fit Model eUwYP-KBZwPart No Description 5 8 10 12 16 20 24oP10 Evaporator Heater Tape £220 £220 £220 £220 £220 £220 £220oPHP High Static Pump £67 £67 £67 £67 £256 £256 £256oPHF High Static Fan £16 £38 £38 £38 £78 £78 £78oPZH Chilled Water Down to -5 £163 £163 £163 £163 £163 £163 £163oPZl Chilled Water Down to -10 £163 £163 £163 £163 £163 £163 £163

To Fit Model eUwYB-KBZwPart No Description 5 8 10 12 16 20 24oP10 Evaporator Heater Tape £270 £270 £270 £270 £270 £270 £270oPHP High Static Pump £67 £67 £67 £67 £256 £256 £256oPHF High Static Fan £16 £38 £38 £38 £78 £78 £78oPZH Chilled Water Down to -5 £163 £163 £163 £163 £163 £163 £163oPZl Chilled Water Down to -10 £163 £163 £163 £163 £163 £163 £163

Fitted Options:

Page 102: Daikin AC Price List 2013

Integrated Solutions

App

lied

100

Water Cooled Chillers

water cooled Packaged scroll compressor – R407c

ewwP014KBw1N 12.90 - 3-phase £2,557.00ewwP022KBw1N 21.40 - 3-phase £3,371.00ewwP028KBw1N 27.80 - 3-phase £3,873.00ewwP035KBw1N 32.30 - 3-phase £4,507.00ewwP045KBw1N 42.80 - 3-phase £5,552.00ewwP055KBw1N 55.70 - 3-phase £6,201.00ewwP065KBw1N 64.70 - 3-phase £6,926.00

Notes:i) Please contact your local sales office for further information on

these products

ii) Nominal cooling capacities are based on chilled water @ 12/7°C, condenser water @ 30/35°C

To Fit Model ewwP-Kaw1NPart No Description 014 022 028 035 045 055 065oPZH Chilled Water Down to -5 £163 £163 £163 £163 £163 £163 £163oPZl Chilled Water Down to -10 £163 £163 £163 £163 £163 £163 £163

Fitted Options:

Cooling Capacity:ModelNo

Nominal coolingkw

Nominalheatingkw

Powersupply

TradePrice

Condenserless Chillers

condenserless Packaged scroll compressor – R407c

ewLP012KBw1N 12.10 - 3-phase PoaewLP020KBw1N 20.00 - 3-phase PoaewLP026KBw1N 26.80 - 3-phase PoaewLP030KBw1N 31.20 - 3-phase PoaewLP040KBw1N 40.00 - 3-phase PoaewLP055KBw1N 53.70 - 3-phase PoaewLP065KBw1N 62.40 - 3-phase Poa

Notes:i) Please contact your local sales office for further information on

these products

ii) Nominal cooling capacities are based on chilled water @ 12/7°C, condensing temperature @ 45°C, liquid temperature @40°C

To Fit Model ewLP-Kaw1NPart No Description 012 020 026 030 040 055 065oPZH Chilled Water Down to -5 Poa Poa Poa Poa Poa Poa PoaoPZl Chilled Water Down to -10 Poa Poa Poa Poa Poa Poa Poa

Fitted Options:

Cooling Capacity:ModelNo

Nominal coolingkw

Nominalheatingkw

Powersupply

TradePrice

Page 103: Daikin AC Price List 2013

Price List 2013 101

App

lied

Applied Systems Kit Options

Model Description Trade PriceBHGP26A1 Digital Pressure gauges - EWAQ/EWYQ-BA £262.00DTA104A62 External control adaptor low noise & demand limit - EWAQ/EWYQ-BA £216.00EHMC10A10 HYDRAUliC MoDUlE -Normal static + anti-freeze protection - EWWP014~022/EWlP012~020 £1,635.00EHMC10A80 HYDRAUliC MoDUlE-High static + anti-freeze protection - EWWP014~022/EWlP012~020 £1,740.00EHMC15A10 HYDRAUliC MoDUlE-Normal static + anti-freeze protection - EWWP028~035/EWlP026~030 £1,740.00EHMC15A80 HYDRAUliC MoDUlE-High static + anti-freeze protection - EWWP028~035/EWlP026~030 £1,811.00EHMC30A10 HYDRAUliC MoDUlE-Normal static + anti-freeze protection - EWWP045~065/EWlP040~065 £1,951.00EHMC30A80 HYDRAUliC MoDUlE-High static + anti-freeze protection - EWWP045~065/EWlP040~065 £1,951.00EKAC10C Address card for connection to BMS - EUWA/Y(N,P,B)5-24KBZW,EWWP,EWlP (note not available on the modular EWWP) £84.00EKRUMCA Remote Control- EUWA/Y(N,P,B)5-24KBZW,EWWP,EWlP (needs EKAC10C) £159.00EKBT Buffertank 200i - EUWA/Y5-24KBZW £1,075.00EKGAU10/12KA Gauges kit 10/12Hp-units - EUWA/Y10-12KBZW £163.00EKGAU16KA Gauges kit 16Hp-units - EUWA/Y16 KBZW £262.00EKGAU20/24KA Gauges kit 20/24Hp-units - EUWA/Y20-24KBZW £262.00EKGAU5/8KA Gauges kit 5/8Hp-units - EUWA/Y5-8KBZW £163.00EKlS1 low noise operation EWlP012~EWWP14 £151.00EKlS2 low noise operation EWlP02~030, EWWP22-35 £151.00EKlS2 X 2 low noise operation EWlP040~065, EWWP45-65 £302.00EKRP1AHT Demand PCB / outputs - EWAQ/EWYQ-BA (2 x on size 40/50/64) £104.00EKRUAHTB Remote user interface (in parallel) - EWAQ/EWYQ-BA £157.00RTD-W MoDBUS interface - EWAQ/EWYQ-BA £205.00

Loose Accessory Options:

Page 104: Daikin AC Price List 2013

Integrated Solutions

App

lied

102

Capacity conditionsEUROVENT conditionscooling27°C db / 19°C wb - Entering water 7°C - Leaving water 12°C

heating 4 Pipe20°C db - Entering water 70°C - Leaving water 60°C

heating 2 Pipe 20°C db - Entering water 50°C - Flow rate as in cooling mode

TYPICAL UK cooling conditions22°C db / 16.0°C wb - Entering water 7°C - Leaving water 12°C0 Pa External Static Pressure0% Glycol

FWB&FWDDuctedFCU-Abovecapacitiesarebasedon30Pa External Static Pressure

FWMUncased&FWEDuctedFCU-Basedon20paexternalstatic

Fan Coil UnitsDaikin’s fan coil range are manufactured in Europe to the same high standard, high quality and reliability as their DX counterparts.

An extensive range of control and valve options are available to complement these quiet and fashionable units.

Page 105: Daikin AC Price List 2013

Price List 2013 103

App

lied

cased Low wall Mount Type 2-pipe FwV01DTN FwV15DTN FwV02DTN FwV25DTN FwV03DTN FwV35DTN FwV04DTN FwV06DTN FwV08DTN FwV10DTNCapacity UK Total Cooling kW 0.82 0.92 1.09 1.24 1.48 1.75 2.14 2.39 3.29 4.00

Nominal Cooling kW 1.54 1.74 2.09 2.42 2.93 3.51 4.33 4.77 6.71 8.02Nominal Heating kW 2.14 2.2 2.57 3.2 3.81 4.78 5.63 6.36 7.83 10.03

Dimensions Height mm 564 564 564 564 564 564 564 564 564 564Width mm 774 774 774 987 987 1194 1194 1194 1404 1404Depth mm 226 226 226 226 226 226 226 226 251 251

Weight kg 19 20 20 25 25 30 30 31 41 41Sound Power High dBA 45 49 50 48 47 52 52 56 58 64Air Flow Rate m3/min 5.32 5.73 5.73 7.36 7.37 10.66 11.77 13.08 16.85 23.22Water Connections inch 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4Electrical Data Power Supply 1ph

Trade Fan coil Price £148.00 £155.00 £163.00 £174.00 £179.00 £196.00 £206.00 £222.00 £295.00 £335.00

cased Low wall Mount Type 4-pipe FwV01DFN FwV15DFN FwV02DFN FwV25DFN FwV03DFN FwV35DFN FwV04DFN FwV06DFN FwV08DFN FwV10DFNCapacity UK Total Cooling kW 0.77 0.90 0.99 1.22 1.37 1.73 2.11 2.33 3.27 3.92

Nominal Cooling kW 1.46 1.69 1.9 2.38 2.87 3.46 4.33 4.67 6.64 7.88Nominal Heating kW 1.9 2.02 2.1 2.92 3.08 4.8 5.05 5.3 7.91 9.3

Dimensions Height mm 564 564 564 564 564 564 564 564 564 564Width mm 774 774 774 987 984 1194 1194 1194 1404 1404Depth mm 226 226 226 226 226 226 226 226 251 251

Weight kg 20 21 21 26 26 32 32 33 44 44Sound Power High dBA 45 49 50 48 47 51 56 59 60 66Air Flow Rate m3/min 5.12 5.5 5.45 7.2 7.18 10.46 11.5 12.72 16.63 22.7Water Connections inch 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4Electrical Data Power Supply 1ph

Trade Fan coil Price £171.00 £179.00 £187.00 £201.00 £208.00 £224.00 £240.00 £259.00 £338.00 £378.00

Floor Standing Fan Coil Units

cased Flexi Type 2-pipe FwL01DTN FwL15DTN FwL02DTN FwL25DTN FwL03DTN FwL35DTN FwL04DTN FwL06DTN FwL08DTN FwL10DTNCapacity UK Total Cooling kW 0.82 0.92 1.09 1.24 1.48 1.75 2.14 2.39 3.29 4.00

Nominal Cooling kW 1.54 1.74 2.09 2.42 2.93 3.51 4.33 4.77 6.71 8.02Nominal Heating kW 2.14 2.2 2.57 3.2 3.81 4.78 5.63 6.36 7.83 10.03

Dimensions Height mm 564 564 564 564 564 564 564 564 564 564Width mm 774 774 774 987 987 1194 1194 1194 1404 1404Depth mm 226 226 226 226 226 226 226 226 251 251

Weight kg 20 21 21 27 27 32 32 33 44 44Sound Power High dBA 45 49 50 48 48 52 53 56 61 67Air Flow Rate m3/min 5.32 5.73 5.73 7.37 7.37 10.66 11.77 13.08 16.85 23.22Water Connections inch 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4Electrical Data Power Supply 1ph

Trade Fan coil Price £161.00 £171.00 £180.00 £188.00 £201.00 £216.00 £227.00 £245.00 £330.00 £372.00

cased Flexi Type 4-pipe FwL01DFN FwL15DFN FwL02DFN FwL25DFN FwL03DFN FwL35DFN FwL04DFN FwL06DFN FwL08DFN FwL10DFNCapacity UK Total Cooling kW 0.77 0.90 0.99 1.22 1.37 1.73 2.11 2.33 3.27 3.92

Nominal Cooling kW 1.46 1.69 1.9 2.38 2.87 3.46 4.33 4.67 6.64 7.88Nominal Heating kW 1.9 2.02 2.1 2.92 3.08 4.8 5.05 5.3 7.91 9.3

Dimensions Height mm 564 564 564 564 564 564 564 564 564 564Width mm 774 774 774 987 987 1194 1194 1194 1404 1404Depth mm 226 226 226 226 226 226 226 226 251 251

Weight kg 21 22 22 28 28 34 34 35 46 46Sound Power High dBA 45 49 50 48 47 51 56 59 60 66Air Flow Rate m3/min 5.12 5.5 5.45 7.2 7.18 10.46 11.5 12.72 16.63 22.7Water Connections inch 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4Electrical Data Power Supply 1ph

Trade Fan coil Price £188.00 £198.00 £204.00 £219.00 £227.00 £251.00 £266.00 £282.00 £375.00 £417.00

Flexi Fan Coil Units

Page 106: Daikin AC Price List 2013

Integrated Solutions

App

lied

104

concealed Flexi Type 2-pipe FwM01DTN FwM15DTN FwM02DTN FwM25DTN FwM03DTN FwM35DTN FwM04DTN FwM06DTN FwM08DTN FwM10DTNCapacity UK Total Cooling kW 0.66 0.92 0.87 1.24 1.27 1.75 1.97 2.11 3.11 3.71

Nominal Cooling kW 1.54 1.74 2.09 2.42 2.93 3.51 4.33 4.77 6.71 8.02Nominal Heating kW 2.14 2.2 2.57 3.2 3.81 4.78 5.68 6.36 7.83 10.03

Dimensions Height mm 535 535 535 535 535 535 535 535 535 535Width mm 584 584 584 794 794 1004 1004 1004 1214 1214Depth mm 224 224 224 224 224 224 224 224 249 249

Weight kg 14 15 15 19 19 23 23 23 32 32Sound Power High dBA 45 49 50 48 47 52 52 56 58 64Air Flow Rate m3/min 5.32 5.73 5.73 7.37 7.37 10.66 11.77 13.08 16.85 23.22Water Connections inch 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4Electrical Data Power Supply 1ph

Trade Fan coil Price £122.00 £130.00 £135.00 £145.00 £150.00 £161.00 £167.00 £184.00 £242.00 £275.00

concealed Flexi Type 4-pipe FwM01DFN FwM15DFN FwM02DFN FwM25DFN FwM03DFN FwM35DFN FwM04DFN FwM06DFN FwM08DFN FwM10DFNCapacity UK Total Cooling kW 0.64 0.90 0.82 1.22 1.26 1.73 1.94 2.08 3.08 3.63

Nominal Cooling kW 1.46 1.69 1.9 2.38 2.87 3.46 4.33 4.67 6.64 7.88Nominal Heating kW 1.9 2.02 2.1 2.92 3.08 4.8 5.05 5.3 7.91 9.3

Dimensions Height mm 535 535 535 535 535 535 535 535 535 535Width mm 584 584 584 794 794 1004 1004 1004 1214 1214Depth mm 224 224 224 224 224 224 224 224 249 249

Weight kg 15 16 16 20 20 25 25 25 34 34Sound Power High dBA 45 49 50 48 47 51 56 59 60 66Air Flow Rate m3/min 5.12 5.73 5.45 7.37 7.18 10.66 11.5 12.72 16.63 22.7Water Connections inch 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4Electrical Data Power Supply 1ph

Trade Fan coil Price £147.00 £153.00 £158.00 £172.00 £177.00 £192.00 £203.00 £217.00 £285.00 £319.00

Low Static Concealed Flexi Fan Coil Units

FwV, FwL, FwM 1-35 4 -6 8 -102-pipe 3-way valve kits c/w lockshields E2MV03A6 E2MV06A6 E2MV10A6

£118.00 £118.00 £125.004-pipe 3-way valve kits c/w lockshields E4MV03A6 E4MV06A6 E4MV10A6

£212.00 £212.00 £222.00Simplified 2 pipe 3-way valve kit w/o lockshields E2MVD03A6 E2MVD06A6 E2MVD10A6

£68.00 £70.00 £72.00Simplified 4 pipe 3-way valve kit w/o lockshields E4MVD03A6 E4MVD06A6 E4MVD10A6

£128.00 £130.00 £132.002-way simplified valve (primary heat exchanger) E2MV207A6 E2MV210A6

£50.00 £50.002-way simplified valve (auxiliary heat exchanger) E2MV207A6

£50.00Vertical drainpan EDPVB6

£3.00Horizontal drainpan EDPHB6

£3.00Standard Electronic Controller FWEC1A

£63.00Advanced Electronic Controller FWEC2A

£80.00Advanced Plus Electronic Controller FWEC3A

£111.00on board installation kit (FWV & FWl - low Wall Mounted only)

FWECKA£10.00

Master slave option EPiMSA6£82.00

Return Air Sensor FWTSKA£7.00

Loose Accessory Options: Notes: FWEC1A individual controller can operate up to 4 fan coils by adding a EPiMSA6

FWEC2A can operate up to 247 fan coils as master slave control (1 per fan coil required)

FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control and 2 digital outputs (1 per fan coil required)

Please note thati) Each controller version includes the

water probe

ii) The on board installation kit includes a remote air probe (if installed the internal fan coil robe is disabled).

Floor Standing and Flexi Fan Coil Unit Accessories

Page 107: Daikin AC Price List 2013

Price List 2013 105

App

lied

concealed Ducted Type 2-pipe Fwe02cT Fwe03cT Fwe04cT Fwe06cT Fwe07cT Fwe08cT Fwe10cTCapacity UK Total Cooling kW 1.10 1.59 2.37 3.65 3.46 4.16 5.78

Nominal Cooling kW 2.17 3.22 4.34 6.06 6.83 7.84 9.96Nominal Heating kW 2.79 4.28 5.61 7.86 9.26 10.5 13

Dimensions Height mm 253 253 253 253 253 253 253Width mm 705 875 1005 1205 1455 1555 1815Depth mm 605 605 605 605 605 605 605

Weight kg 17 20 24 28 37 39 46Sound Power Super High dBA 51 61 58 62 62 64 65Air Flow Rate m3/min 7.16 10.63 15.16 19.92 25.98 29.22 36.28Water Connections inch 3/4Electrical Data Power Supply 1ph

Trade Fan coil Price £129.00 £147.00 £159.00 £208.00 £224.00 £262.00 £316.00

concealed Ducted Type 4-pipe Fwe02cF Fwe03cF Fwe04cF Fwe06cF Fwe07cF Fwe08cF Fwe10cFCapacity UK Total Cooling kW 1.03 1.52 2.22 3.33 3.05 3.87 5.07

Nominal Cooling kW 2.1 3.16 3.98 6.05 6.78 7.79 9.91Nominal Heating kW 2.3 3.53 4.56 6.17 7.6 8.52 10.4

Dimensions Height mm 253 253 253 253 253 253 253Width mm 720 890 1020 1220 1470 1570 1830Depth mm 605 605 605 605 605 605 605

Weight kg 18 22 25 30 40 41 49Sound Power Super High dBA 51 61 58 62 62 64 65Air Flow Rate m3/min 6.94 10.44 13.91 19.88 25.79 29.03 36.1Water Connections inch 3/4Electrical Data Power Supply 1ph

Trade Fan coil Price £151.00 £172.00 £187.00 £240.00 £256.00 £299.00 £353.00

Low Static Ducted Fan Coil Units

Fwe Fwe2-pipe 2-way 230v on/off valve kit EK2MV2B10CS

£41.002-pipe 3-way 230v on/off valve kit EK2MV3B10CS

£55.004-pipe 2-way 230v on/off valve kit EK4MV2B10CS

£80.004-pipe 3-way 230v on/off valve kit EK4MV3B10CS

£94.00Standard Electronic Controller FWEC1A

£63.00Advanced Electronic Controller FWEC2A

£80.00Advanced Plus Electronic Controller FWEC3A

£111.00Return Air Sensor FWTSKA

£7.00Master slave interface EPiMSA6

£82.00

Loose Accessory Options: Notes: FWEC1A individual controller can operate up to 4 fan coils by adding a EPiMSA6

FWEC2A can operate up to 247 fan coils as master slave control ( 1 per fan coil required)

FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control and 2 digital outputs ( 1 per fan coil required)

Please note thati) Each controller version includes the

water probe

ii) The on board installation kit includes a remote air probe( if installed the internal fan coil robe is disabled).

Page 108: Daikin AC Price List 2013

Integrated Solutions

App

lied

106

concealed Ducted Type 2-pipe FwB02BT*** FwB03BT*** FwB04BT*** FwB05BT*** FwB06BT*** FwB07BT*** FwB08BT*** FwB09BT*** FwB10BT***Capacity UK Total Cooling kW 1.71 2.09 2.26 3 3.24 3.84 4.63 5.34 6.64

Nominal Cooling kW 2.61 3.14 3.49 5.08 5.45 6.47 7.57 8.67 10.34Nominal Heating kW 5.47 6.01 6.47 10.31 11.39 12.28 15.05 16.85 18.78

Dimensions Height mm 239 239 239 239 239 239 239 239 239Width mm 1039 1039 1039 1389 1389 1389 1739 1739 1739Depth mm 609 609 609 609 609 609 609 609 609

Weight kg 23 24 26 31 33 35 43 45 48Sound Power High dBA 56 56 56 59 59 59 69 69 69Air Flow Rate m3/min 6.67 6.67 6.67 13.33 13.33 13.33 20 20 20Water Connections inch 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4Electrical Data Power Supply 1ph

Trade Fan coil Price - no valves FwB02BTN FwB03BTN FwB04BTN FwB05BTN FwB06BTN FwB07BTN FwB08BTN FwB09BTN FwB10BTN£219.00 £233.00 £248.00 £299.00 £309.00 £338.00 £409.00 £431.00 £459.00

Trade Fan coil Price - complete with valves FwB02BTV FwB03BTV FwB04BTV FwB05BTV FwB06BTV FwB07BTV FwB08BTV FwB09BTV FwB10BTV£288.00 £303.00 £317.00 £369.00 £378.00 £409.00 £481.00 £506.00 £535.00

Trade Fan coil Price - complete with electronic heater*, no valves

FwB02BTNe FwB03BTNe FwB04BTNe FwB05BTNe FwB06BTNe FwB07BTNe FwB08BTNe FwB09BTNe FwB10BTNe£353.00 £367.00 £382.00 £448.00 £457.00 £486.00 £567.00 £589.00 £618.00

Trade Fan coil Price - complete with electronic heater* and valves

FwB02BTVe FwB03BTVe FwB04BTVe FwB05BTVe FwB06BTVe FwB07BTVe FwB08BTVe FwB09BTVe FwB10BTVe£423.00 £436.00 £451.00 £517.00 £528.00 £557.00 £641.00 £663.00 £692.00

Medium Static Ducted Fan Coil Units

FwB 2 - 4 5 - 7 8 - 10Additional Heat exchanger EAH04A6 EAH07A6 EAH10A6

£87.00 £101.00 £137.003-way valve add.h/e E2MV307A6 E2MV310A6

£89.00 £89.002-way valve add.h/e E2MV207A6 E2MV210A6

£50.00 £50.00Master slave interface EPiMSA6

£82.00Standard Electronic Controller FWEC1A

£63.00Advanced Electronic Controller FWEC2A

£80.00Advanced Plus Electronic Controller FWEC3A

£111.00Return Air Sensor FWTSKA

£7.00

Loose Accessory Options: Notes: FWEC1A individual controller can operate up to 4 fan coils by adding a EPiMSA6

FWEC2A can operate up to 247 fan coils as master slave control ( 1 per fan coil required)

FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control and 2 digital outputs (1 per fan coil required)

Please note that:i) Each controller version includes the

water probe.

Page 109: Daikin AC Price List 2013

Price List 2013 107

App

lied

concealed Ducted Type 2-pipe FwD04aT FwD06aT FwD08aT FwD10aT FwD12aT FwD16aT FwD18aTCapacity UK Total Cooling kW 2.15 3.48 4.44 4.92 7.21 8.96 9.91

Nominal Cooling kW 3.9 6.2 7.8 8.82 11.9 16.4 18.3Nominal Heating kW 4.05 7.71 9.43 10.79 14.45 19.81 21.92

Dimensions Height mm 280 280 280 280 352 352 352Width mm 754 964 1174 1174 1174 1384 1384Depth mm 559 559 559 559 718 718 718

Weight kg 33 41 47 49 65 77 80Sound Power High dBA 66 69 72 72 74 78 78Air Flow Rate m3/min 13.33 20.83 26.67 26.67 36.67 50 50Water Connections inch 3/4 3/4 3/4 3/4 1 1 1 Electrical Data Power Supply 1ph

Trade Fan coil Price £264.00 £348.00 £406.00 £452.00 £562.00 £721.00 £792.00

concealed Ducted Type 4-pipe FwD04aF FwD06aF FwD08aF FwD10aF FwD12aF FwD16aF FwD18aFCapacity UK Total Cooling kW 2.15 3.48 4.44 4.92 7.21 8.96 9.91

Nominal Cooling kW 3.9 6.2 7.8 8.82 11.9 16.4 18.3Nominal Heating kW 4.05 7.71 9.43 10.79 14.45 19.81 21.92

Dimensions Height mm 280 280 280 280 352 352 352Width mm 754 964 1174 1174 1174 1384 1384Depth mm 559 559 559 559 718 718 718

Weight kg 35 43 50 52 71 83 86Sound Power High dBA 66 69 72 72 74 78 78Air Flow Rate m3/min 13.33 20.83 26.67 26.67 36.67 50 50Water Connections inch 3/4 3/4 3/4 3/4 1 1 1 Electrical Data Power Supply 1ph

Trade Fan coil Price £309.00 £404.00 £472.00 £523.00 £658.00 £836.00 £916.00

High Static Ducted Fan Coil Units

FwD 4 6 8 -10 12 16 -182-pipe 3-way valve ED2MV04A6 ED2MV10A6 ED2MV12A6 ED2MV18A6

£125.00 £125.00 £125.00 £130.004-pipe 3-way valve ED4MV04A6 ED4MV10A6 2x ED2MV12A6 2 x ED2MV18A6

£239.00 £239.00 £250.00 £260.00Vertical Drain pan EDDPV10A6 EDDPV18A6

£10.00 £10.00Horizontal Drain Pan EDDPH10A6 EDDPH18A6

£12.00 £12.00Master slave interface EPiMSA6 -

£82.00 -Power interface (S) EPiB6

£82.00Standard Electronic Controller FWEC1A

£63.00Advanced Electronic Controller FWEC2A

£80.00Advanced Plus Electronic Controller FWEC3A

£111.00Return Air Sensor FWTSKA

£7.00

Loose Accessory Options: Notes: FWEC1A is designed as an individual unit controller. Power interface EPiB6 is required for unit size 16 and 18 can operate up to 4 fan coils by adding a EPiMSA6.

if using this controller to operate up to 4 fan coil units by adding a EPiMSA6 you will require a EPiB6 power interface for unit size 12,16,18.

FWEC2A can operate up to 247 fan coils as master slave control ( 1 per fan coil required). Power interface EPiB6 is required for each unit size 16 and 18.

FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control (by others) and 2 digital outputs ( 1 per fan coil required).

Please note that:i) Each controller version includes the

water probe.

Page 110: Daikin AC Price List 2013

Integrated Solutions

App

lied

108

600sq cassette Type 2-pipe c/w Decoration Panel and Remote controller

FwF02BT FwF03BT FwF04BT FwF05BT

Capacity UK Total Cooling kW 1.20 1.9 2.5 3.1Nominal Cooling kW 2 3.2 4.2 5.2Nominal Heating kW 2.9 4 5.4 6.7

Dimensions Height mm 260 260 260 260Width mm 575 575 575 575Depth mm 575 575 575 575

Weight kg 19 19 19 19Sound Power High dBA 44 44 50 55Air Flow Rate m3/min 7.9 7.9 11.2 14.9Water Connections inch 3/4 “ BSP FemaleElectrical Data Power Supply 1 ph

Trade Fan coil Price £498.00 £524.00 £553.00 £591.00

600sq cassette Type 4-pipe c/w Decoration Panel and Remote controller

FwF02BF FwF03BF FwF04BF FwF05BF

Capacity UK Total Cooling kW 1.10 1.6 2 2.5Nominal Cooling kW 2 2.7 3.5 4.5Nominal Heating kW 3.9 3.8 4.9 6.1

Dimensions Height mm 260 260 260 260Width mm 575 575 575 575Depth mm 575 575 575 575

Weight kg 19 20 20 20Sound Power High dBA 44 46 52 57Air Flow Rate m3/min 7.9 7.2 10.4 13.9Water Connections inch 3/4 “ BSP FemaleElectrical Data Power Supply 1 ph

Trade Fan coil Price £530.00 £553.00 £591.00 £624.00

600 Sq Cassette Fan Coil Units

cassette Type 2-pipe c/w Decoration Panel and Remote controller

Fwc06BT Fwc07BT Fwc08BT Fwc09BT

Capacity UK Total Cooling kW 3.30 4.1 4.3 4.8Nominal Cooling kW 5.8 6.8 7.7 8.7Nominal Heating kW 8 8.9 10.6 12.1

Dimensions Height mm 288 288 288 288Width mm 840 840 840 840Depth mm 840 840 840 840

Weight kg 26 26 26 26Sound Power High dBA 46 49 55 59Air Flow Rate m3/min 17.7 20.6 25.4 30.8Water Connections inch 3/4 “ BSP FemaleElectrical Data Power Supply 1 ph

Trade Fan coil Price £625.00 £641.00 £657.00 £684.00

cassette Type 4-pipe c/w Decoration Panel and Remote controller

Fwc06BF Fwc07BF Fwc08BF Fwc09BF

Capacity UK Total Cooling kW 3.30 4 4.3 4.8Nominal Cooling kW 5.8 6.6 7.6 8.7Nominal Heating kW 7.5 8.4 9.7 11

Dimensions Height mm 288 288 288 288Width mm 840 840 840 840Depth mm 840 840 840 840

Weight kg 29 29 29 29Sound Power High dBA 43 47 53 57Air Flow Rate m3/min 17.1 19.9 24.6 29Water Connections inch 3/4 “ BSP FemaleElectrical Data Power Supply 1 ph

Trade Fan coil Price £653.00 £676.00 £694.00 £711.00

Cassette Fan Coil Units

Page 111: Daikin AC Price List 2013

Price List 2013 109

App

lied

FwF/Fwc FwF/FwcRemote wired controller (requires KJB212A) BRC315D

£65.00Recessed fixing box for BRC315D & DCS301B51 KJB212A

£36.00intelligent touch controller DCS601C51

£1,608.00Recessed fixing box for DCS601C51 KJB411A

£67.00Unit/Group adapter pcb KRP4A53

£65.00Unit/Group adapter pcb complete with installation box

KRP4A53/UK.FB2£89.00

System adaptor pcb KRP2A52£173.00

System adaptor pcb complete with installation box

KRP2A52/UK.FB2£197.00

optional pcb for connection to ModBus EKFCMBCB£53.00

2-Way on / off valve kit EKMV2C09B£56.00

3-Way on / off valve kit EKMV3C09B£62.00

Valve control PCB EKRP1C11£98.00

Fwc only Fwc onlyWireless remote control heat pump BRC7FA532F

£149.00Wireless remote control cooling only BRC7F533F

£149.00Remote air sensor KRCS01-4

£46.00installation box for an EKRP1C11 valve PCB UK.FB2

£36.00

FwF only FwF onlyWireless remote control heat pump BRC7E530

£118.00Wireless remote control cooling only BRC7E531

£118.00System adaptor pcb KRCS01-1

£45.00Remote on/off control interface kit EKRoRo

£15.00installation box for an EKRP1C11 valve PCB UK.FB2

£36.00

Loose Accessory Options: Notes:i) FWF and FWC Cassette Fan Coil prices

include decoration panel

ii) it is not possible to use intelligent Touch control for combination with both VRV and water based fan coils

FwF-Valve control requirements 2 pipe unit: 1 x valve kit + 1 x installation

box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11

4 pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11

Fwc-Valve control requirements 2 pipe unit: 1 x valve kit + 1 x installation

box for PCB KRP1H98 + 1 x valve control PCB EKRP1C11

4 pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control PCB EKRP1C11

Cassette Accessories

cased high wall Mount Type 2-pipe FwT02cT FwT03cT FwT04cT FwT05cT FwT06cTCapacity UK Total Cooling kW 1.59 1.67 2.1 2.9 3.41

Nominal Cooling kW 2.43 2.7 3.31 4.54 5.28Nominal Heating kW 3.22 3.52 4.4 6.01 5.26

Dimensions Height mm 288 288 288 310 310Width mm 800 800 800 1065 1065Depth mm 206 206 206 224 224

Weight kg 10 10 10 15 15Sound Power High dBA 45 48 55 55 59Air Flow Rate m3/min 7.36 7.93 10.48 14.43 17.55Water Connections inch 1/2 1/2 1/2 1/2 1/2Electrical Data Power Supply 1ph

Trade Fan coil Price £192.00 £200.00 £229.00 £277.00 £295.00

Wall Mounted Fan Coil Units

FwT FwTStandard wired remote controller MERCA

£74.00Simplified wired remote controller SRC-HPA

£38.00Wireless controller for heat pump WRC-HPB

£14.00

Loose Accessory Options: Notes:i) FWT fan coils are optimised for valveless

control in cooling. We would recommend that a valve is fitted if being used for heating only and for more precise control in cooling.

ii) We would recommend the field supply of a 240V - 4 port 3 way valve complete with 240V actuator.

Page 112: Daikin AC Price List 2013

App

lied

110

Page 113: Daikin AC Price List 2013

111

Mis

cella

neou

s

scotland Region

0845 641 9330

Northern Region

0845 641 9340

Midlands Region

0845 641 9370

western Region

0845 641 9320

North London

0845 641 9360

south London

0845 641 9355

MiscellaneousSchematics&MalfunctionCodes 112

Delivery Information 114

Goods Returns Procedure 115

Field Quality Service 116

Warranty 117

Training 118

Terms&Conditions 120

Page 114: Daikin AC Price List 2013

Integrated Solutions

Mis

cella

neou

s

112

Wiring DiagramSkyAir&SplitInterconnectingWiring

Wiring Adaptor for External ControlKRP4A51-52-53-54

Page 115: Daikin AC Price List 2013

Price List 2013 113

Mis

cella

neou

s

Wiring Adaptor for External ControlKRP4A51-52-53-54

Overall Malfunction Display on Daikin LCD Controller2nd

1st 0 1 2 3 4 5 6 7 8 9 A C E F H J

Indo

or

AProtection

Device Activated (General)

Faulty Indoor PCB Abnormal Drain H2O Level

Abnormal Heat Exchanger 1 Temperature

Abnormal Heat Exchanger 2 Temperature

Fan Motor Overload & Over

Current Lock

Air Swing Motor Lock

AC Input Over Current

Faulty Electronic Expansion Valve

Backup Heater Thermal Protector

Activated

Booster Heater Thermal Protector

Insufficient Water Supply Faulty Humidifier Faulty Or Dirty

Dust Collector

Faulty Capacity Setting Plug

(Indoor)

C Flow Switch Abnormality

Failure of Transmission

Between Indoor Unit & Sub PCB’s

Faulty Drain H2O Level Sensor

System

Malfunction of Liquid Pipe Thermisor for

Heat Exchanger

Malfunction of Gas Pipe

Thermisor for Heat Exchanger

Fan Motor OL/OC, Lock Sensor Incorrect

combination Fandrive/Set

Air Swing Motor Lock Faulty Sensor

System

Faulty AC Input Current Sensor

System.

Malfunction of Suction Air

Thermisor

Malfunction of Discharge Air

Thermistor

Malfunction of Humidity Sensor

System

Malfunction of Switch Box

Thermistor

Faulty High Pressure Switch

Malfunction of Thermistor

in Remote Controller

out

door

ESafety Device

Activation (General)

Faulty Outdoor PCB

Activation of High Pressure Switch

(HPS)

Activation of Low Pressure Switch

(LPS)

Activation of Inverter Compressor

Motor Overload

Compressor Over Current Lock

Fan Motor OL.OC. Lock

OC of Inverter Compressor

Faulty Electronic Expansion Valve

Malfunction of 4-Way Valve Cool/

Heat Switching

Abnormal Water Temperature

Faulty Drain H2O Level System

Faulty Heat Storage Unit Pump OC. Lock

Activation Of Local Safety

Device

FActivation Safety

Device (Syst.No.1)

Activation Safety Device (Syst.

No.2)

Faulty Discharge Pipe Temperature

Malfunction of Suction Pipe Thermistor

Abnormal High Pressure or Refrigerant

Overcharge

Expansion Valve faulty In BSVQ-P

Abnormal discharge pressure

Abnormal suction pressure

Abnormal Oil Pressure

Abnormal Oil Surface Level

Abnormal High Oil Temperature

H Voltage & Current Sensor Failure

Faulty Air Temperature

Sensor System Damper Fail

Faulty Power Supply Sensor

System

Faulty High Pressure Switch

(HPS)

Faulty Low Pressure Switch

(LPS)

Compressor Motor Faulty OL. Sensor

System

Compressor Motor OC. Lock Faulty Sensor System

Fan Motor OL OC, Faulty Lock Sensor

System

Faulty AC Input Power Sensor

System

Malfunction of Outdoor Air

Thermistor

Malfunction of Discharge Air

Thermistor

Malfunction of Domestic Hot

Water Tank Thermistor

Faulty drain H2O level Sensor

System

Heat Storage Unit Alarm

Float switch (local supply) Open (if

Mode 2-26)

JFaulty Refrigerant

Temperature Sensor System

Malfunction of Pressure Sensor

Faulty Current Sensor System

Malfunction of Discharge Pipe

Thermistor

Faulty LP Equiv. Sat. Temperature

Sensor System

Malfunction of Suction Pipe Thermistor

Faulty Heat Exchanger 1 Temperature

Sensor System

Faulty Heat Exchanger 2 Temperature

Sensor System

Faulty Liquid Pipe Temperature

Sensor System

Faulty Gas Pipe Temperature

Sensor System

Faulty Discharge Pressure Sensor

System

Faulty Suction Pressure Sensor

System

Faulty Oil Pressure Sensor System

Malfunction of Oil Level Sensor

or Heating HeatX thermistor

Faulty Oil Temperature

Sensor System

l Faulty Inverter System

Malfunction of Inverter PCB

Abnormal Temperature Rise

In Switch Box

Abnormal Temperature Rise

Radiation Fin Thermistor

Inverter Instantaneous OC

(DC output)

Inverter Instantaneous OC

(AC output)

Inverter Compressor OC

Detection

Compressor Stall Prevention

Faulty power transistor

Malfunction of Transmission

Between Control & Inverter PCB

P Gas Short. ice thermal stor. Eqp.

Missing Phase. Unbalanced

Power Supply

Auto charge Stopped At Step 5 BS4 Not Pushed

Malfunction of Thermistor in

Switch Box

Faulty Radiant Fin Temperature Sensor System

Faulty DC Current Sensor System

Faulty AC or DC Output Current Sensor System

Malfunction of Total Input

Current Sensor

Autocharge Should Be Restarted

Autocharge Judgement: Finished OK

Replace Charge Cylinder “Master”

Replace Charge Cylinder “Slave 2”

Auto charge Almost finished

Leak Test not poss w/o input add

charge

Replace Charge Cylinder “Slave 1”

Faulty Capacity Setting Plug

(Outdoor)

syst

em

U Shortage of Refrigerant

Reversed or Open Phase Connected

Faulty Power Supply Voltage

System

Faulty Transmission

or Test Run Not Executed

Faulty Transmission

Indoor ↔ Outdoor Units

Faulty Transmission.

Indoor Unit ↔ Remote Control

Faulty Transmission Indoor Units (Master ↔

Slave)

Malfunction of Transmission

between Outdoor Units

Faulty Transmission

between Remote Controllers

Malfunction of Transmission

between Indoor/Outdoor Unit in Same System

Faulty On Site Setting

Address Duplication or

Incorrect Setting

Faulty Transmission Indoor Unit

↔ Centralised Control

Incorrect Wiring/Piping (Wiring/

Piping Connection Error)

Indoor/Outdoor unit address not

entered

Fault communication

to/from peripheral equipment

MMalfunction

of Centralised Remote Controller

PCB

Malfunction of Transmission ↔

Optional Controller for Centralised

Control

Improper Comb. of Optional

Controllers for Centralised

Control

Address Duplication /

Improper Setting

oth

er

6HRV External

Protection Device Activated

Faulty PCB Abnormal Ozone Concentration Faulty dirt sensor

Malfucntion of Thermistor for Indoor Air HRV

Malfunction of Thermistor for

Outdoor Air HRV

Malfunction of Damper System

HRV

Humidifier Element

Replacement

Replace the Deodorising

Catalyst

Simplified Remote Control

Malfunction HRV

Door Switch Open HRV

Replace High-Efficiency Filter

7System no. 2 Compressor

Overheat

System no. 2 Compressor Over

Current

System no.2 Fan Motor Over

Current

System no. 2 Activation of HP

Switch

System no. 2 Activation of LP

Switch

System no. 2 Malfunction of LP

sensor

System no. 2 Malfunction of HP

sensor

System no. 1 Malfunction of Fan Interlock (defect of

relay contact)

System no. 2 Malfunction of Fan Interlock (defect of

relay contact)

System no. 2 Malfunction

of Compressor Current Sensor

Malfunction of Pump Interlock

Flow Failure Insufficient Water

Flow

8Inlet Water

Temperature Thermistor

Outlet Water Temperature Thermistor

System no. 1 Malfunction

of Refrigerant Thermistor

System no. 2 Malfunction

of Refrigerant Thermistor

System no. 1 Malfunction of Heat Exchange

Thermistor

System no. 2 Malfunction of Heat Exchange

Thermistor

System no. 1 Malfunction of Discharge Pipe

Thermistor

System no. 2 Malfunction of Discharge Pipe

Thermistor

Heat Exchanger Freeze Up

Malfunction of Leaving Water Temperature Thermistor

System no. 1 Malfunction of Suction Pipe Thermistor 1 for

Heating

System no. 1 Malfunction of Suction Pipe Thermistor 2 for

Heating

Outlet Water Temperature Thermistor

9 Low Water Volume Detection

System no. 2 Defect of EEV Coil

System no. 2 Defect of Suction Pipe Thermistor

Malfunction of Transmission

HRV ↔ Indoor Fan Units

System no. 1 Malfunction

of Fan Inverter System

System no. 2 Malfunction

of Fan Inverter System

Defect of Thermal Storage Unit

Thermal Storage Unit Brine Pump O/C

Thermal Storage Brine Tank Low

Water Level

System no. 2 Malfunction of Suction Pipe Thermistor 1 for

Heating

System no. 2 Malfunction of Suction Pipe Thermistor 2 for

Heating

caution: Some displayed malfunction codes may have another meaning. Consult the relevant service manual for details.

Page 116: Daikin AC Price List 2013

Integrated Solutions

Mis

cella

neou

s

114

Delivery InformationNotes:•Weekday=MondaytoFriday

8:00am to 17:00pm

•Standarddeliveryvehicleis17.5ton lorry or smaller with tail lift

•Amendmentorcancellationafter order entry deadline my be subject to additional costs

•Timespecificisarequesteddelivery time plus or minus 30 mins

•Deliveryaddress,sitecontactname and number are provided and any delivery restrictions must be communicated prior to order entry deadline

•95%ofmainlandUKdeliveries=next day

•Postcodeswith2-3daystransportation lead-time attached in appendix 1 (isle of Wight = 2 day transportation lead time)

•Driverisnotpermittedtomakepart delivery against a delivery note. Additional charges may apply for refused deliveries

Material code Description cost order processing deadlinestandard Delivery Mon - Fri 8:00am to 17:00pm (excluding spares)Standard delivery

Standard delivery Included order processed by 14:00 Day 1 Delivery Day 2

standard hours (8:00am - 17:00pm) Timed Deliveries (excluding spares) UK.DlVWiN1 8:00am - 13:00hrs weekdays £50.00 order processed by 14:00 Day 1 Delivery Day 2UK.DlVWiN2 12:30 - 17:00hrs weekdays £45.00 order processed by 14:00 Day 1 Delivery Day 2UK.TDN_30min Time specific 30 min window during standard hours £220.00 order processed by 14:00 Day 1 Delivery Day 2

outside standardUK.TDo_30min Time specific 30 min window outside standard hours £290.00 order processed by 14:00 Day 1 Delivery Day 2UK.RUSH Same day delivery (geographical restrictions apply) £220.00 order processed 11:00

weekend Deliveries excluding sparesUK.TDo_30min Time specific 30 min window outside standard hours £290.00 order processed by 14:00 Day 1 Delivery Day 3 or 4 (as requested)UK.SAT_Courrier less than 15KG £35.00 order processed by 14:00 Day 1 Delivery Day 2UK.SAT_Sub Greater than 15KG £110.00 order processed Day 1 Delivery Day 3 Public holidays - request for deliveries on public holidays are considered on an individual basis

special Vehicles standard Delivery Monday to FridayUK.Special Hiab (includes time slot) £340.00 order processed by 14:00 Day 1 Delivery day 3

Flat bed (includes time slot)UK.Van Transit van (size restrictions) £100.00 order processed by 14:00 Day 1 Delivery Day 2

special Vehicles weekendsUK.Special Hiab (includes time slot) £340.00 order processed by 14:00 Day 1 Delivery Day 3 or 4 (as requested)

Flat bed (includes time slot)UK.Van Transit van (size restrictions) £100.00 order processed by 14:00 Day 1 Delivery Day 2Public holidays - request for deliveries on public holidays are considered on an individual basis

2 DaY TRaNsPoRTaTIoN LeaDTIMe = UKcFU2AB BT HS iM iV KA KW PA PH ZE

3 DaY TRaNsPoRTaTIoN LeaDTIMe = UKcFU3GY HS JE KW ZE

Page 117: Daikin AC Price List 2013

Price List 2013 115

Mis

cella

neou

s

Units & accessories: 10 working days from invoicespare Parts: 1 month from date of invoice

Goods Returns ProcedureDaikin UK policy for acceptable returned goods

Daikin may accept unwanted goods provided they are boxed in the original packaging, in perfect condition and have not been used. To arrange the process of returning goods, please complete a Goods Returns Form available from www.daikin.co.uk/business-partners/trade and send by fax or email to the following:

Units & accessories: Fax: 0845 641 9150 or email: [email protected]

spare Parts: Fax: 0845 641 9299 or email: [email protected]

conditions of Returned GoodsAll returned items are subject to a minimum 20% restocking/administration charge with the following collection charges applied to the final credit:

Collected goods up to 15KG: £15

Collected goods over 16KG: £90

All returned goods will be fully inspected by our technical engineers. If returned goods are a non-satisfactory condition then Daikin reserve the right to decline the return or apply an increase to the restocking charge.

Damaged ItemsWe cannot accept claims for damages unless the goods are signed for as damaged on the delivery note and notification is received within 3 working days. Any damage identified can be refused at point of delivery.

what happens NextOnce the returned goods form is received, an email will be sent to the confirmation email address provided notifying you of the goods for collection and a date for this to be carried out. If you have any queries regarding this date please respond to the email address provided as soon as possible.

Once inspected and confirmation is received that the goods are in perfect condition, a credit will be raised against the original invoice.

*Please note returns for chillers and made to order units will not be accepted*

Goods covered by warrantyOnce a unit has been installed and commissioned, any faults or breakdowns that occur these should be reported to our warranty department on:

Telephone: 0845 641 9275 or email: [email protected]

Daikin UK policy for acceptable returned goods are as follows:

Page 118: Daikin AC Price List 2013

Integrated Solutions

Mis

cella

neou

s

116

aftersales Technical helpdeskThis invaluable service offers technical support and guidance when you are experiencing on-site problems commissioning or diagnosing faults. Final diagnosis is the responsibility of the site engineer.

YourcallswillbeansweredbyDaikintrainedengineers.Tohelpprovide a quick and efficient response please make sure you have the full model number of the unit. It is important to remind you that using the D1/D1+ PIN number gives you priority access to our engineers.

You can access this service Mon – Fri 8.30 -5.30pm

Tel 0845 641 9200

Fax 0845 641 9299

email [email protected]

sMs Fault code service 07797 801908

If you need an explanation and remedy on a fault code and haven’t got your service manual, just send the fault code to our SMS message service and we will advise you by return.

Field serviceWe can provide field engineers to assist you on-site for commissioning or service intervention. All work is documented in a report and sent for your records. Since we are working on your site on your behalf it is essential that you are in attendance at that time.

To book an engineer contact us on:

Tel 0845 641 9229

email [email protected]

workshopIn our workshop on the outskirts of Bristol we modify standard Daikin equipment to current specifications that meet our client’s needs. The modifications include weatherised vams, floor mounted fan coil conversions, strip and rebuild to name a few. Think of the savings in time and money by having your nextVRV®outdoorunitdeliveredtositeinsectionsforplacingin position on the roof, saving at the cost of cranes and road closure applications. Speak to your sales representative for more information on what is available.

sparesWhen a component fails, field expertise is pointless unless you have quick access to spares. Daikin have over 12,000 parts based in the UK, supported by our European parts centre with 600,000 parts. This helps us to achieve our target of providing 95% of critical A parts within a 2 day delivery.

To contact the spares team directly

Tel 0845 641 9230

Fax 0845 641 9299

email [email protected]

If you hold a direct account with Daikin UK, you can send your spare parts order to us directly using our Spares Parts Bank. This is available 24 hours a day 365 days a year, and allows you to view and order your parts online at any time of day. Plus, all orders processed through Spares Parts Bank have no delivery charge, which is equivalent to almost 5% extra discount.

To register for Spares Parts Bank go to www.daikin.co.uk/spares.

The Field Quality Service department (FQS)

The Field Quality Service department (FQS) supply a range of services to support the installer.

Page 119: Daikin AC Price List 2013

Price List 2013 117

Mis

cella

neou

s

Daikin UK commercial warrantyIf you have a component failure and it is within the warranty period then we are here to help. After you have spoken to our helpdesk to confirm diagnosis, you can simply contact the warranty team.

contact the warranty team on:

Tel 0845 641 9275

Fax 0845 641 9298

email [email protected]

Youcanalsoprocessyourclaimonlineatthewarrantysectionofthe Extranet. Here you will find process claim forms and our full warranty terms.

The following sets out the Daikin Airconditioning UK Ltd (Daikin UK) current warranty policies:

•Standardwarrantyis3yearspartsandlabour

•Daikinoffer5yearsplusdoublelabourallowanceto D1 /D1+ approved installers

Within the warranty period, products are guaranteed against manufacturing faults in material and workmanship. Replacement parts will be supplied free of charge, together with a fixed labour allowance, as set out in the table below, provided the correct procedures are complied with.

The warranty policies are subject to the following conditions:

•TheDaikinequipmentisinstalledcommissionedandmaintained throughout by a suitably qualified and certificated refrigeration engineer, and in accordance with the manufacturer’s recommendations

•TheengineerhasattendedaDaikinTrainingcourserelevanttothe equipment being installed

•Repeatwarrantyreplacementswillbesubjecttoinvestigationby the manufacturer

•Daikinproductsthatarerelocatedfromtheiroriginalinstallation are excluded

•Normalwearandtearisexcluded

Procedure:

•DaikinUKreceiveaclaimforwarrantyreplacement:dispatchparts, together with warranty forms, returns documentation and invoice

•ThewarrantyformsmustbereturnedtoDaikinUKwithin14days. Faulty parts must be available for collection by Daikin UK for up to 60 days

•DaikinUKreceivecorrectlycompletedclaimform(andfaultyparts if required) and then issue the appropriate credit or technical rejection

•Anyclaimsubmittedthirty(30)daysafterinvoicedateWILLNOT be considered for credit

•AnyclaimnotsubmittedinaccordancewithourproceduresWILL NOT be considered for credit

•Paymentforwarrantyclaimswillonlybemadebycreditnote

•Anyadditionalcostassociatedwiththereplacementoftheactual warranty part (i.e. any cost not itemised in the list of allowances, travel, refrigerant, waiting time, access equipment) will be disallowed by Daikin UK

•Throughoutthewarrantyperiodmaintenancerecordsmustbekept and available for inspection upon request

General components 3 year allowances 5 year allowances

A1 Replacement of components within refrigeration circuit £52.00 £104.00

A2 Repair of internal pipework (does not include installation pipework) £28.00 £56.00

A3 Replacement of air supply fan motor (evaporator and condenser fan motor) £20.00 £40.00

A4 Replacement of fan blade £16.00 £32.00

A5 Replacement of electrical/electronic components £16.00 £32.00

A6 Replacement of condensate drain lift up mechanism £12.00 £24.00

A7 Replacement of auto swing louvre motor £12.00 £24.00

A8* Dead on arrival of unit (packaged type) £40.00 £80.00

A9* Dead on arrival of unit (split type) £72.00 £144.00

* Note: A8 & A9 will be single payment if unit is returned without any repairs

compressors size 3 year allowances 5 year allowances

B1 < 2.5 HP £84.00 £168.00

B2 2.5 HP < 5 HP £100.00 £200.00

B3 5HP < 10 HP £150.00 £300.00

B4 10 HP < 20 HP £200.00 £400.00

B5 25 HP < 50 HP £260.00 £520.00

B6 50 HP < 100 HP £360.00 £720.00

B7 100 HP > £480.00 £960.00

Daikin UK reserve the right to update this warranty (and its terms and conditions), from time to time, without notice.

Page 120: Daikin AC Price List 2013

Integrated Solutions

Mis

cella

neou

s

118

Latest range of products Courses are available to attend at Bristol, Woking, Birmingham, Manchester and Glasgow. The Daikin UK regional training centres are fully equipped with the latest range of products, installed and fully operational for maximum hands on experience.

All training is given by highly skilled engineers who will be able to provide you with extensive in depth knowledge of our equipment. If you have any specific training requests outside of the scheduled programme, please contact us.

a general overview of the style of course content offered:

1. Installation and commissioning requirements

2. Advanced service and fault finding for field engineers

3. Product selection and application techniques

4. Daikin centralised control systems application and commissioning

Daikin UK training centres

BristolDaikin Airconditioning UK Limited

Maple House, Brotherswood Court,

Great Park Road, Almondsbury,

Bristol BS32 4QW

WokingDaikin Airconditioning UK Limited

1 River Court, Albert Drive, Woking,

Surrey GU21 5RP

BirminghamDaikin Airconditioning UK Limited

Unit 8, Holly Park, Spitfire Road,

Birmingham, West Midlands B24 9PB

ManchesterDaikin Airconditioning UK Limited

17b Cobra Court, Blackmore Road,

ManchesterM320QY

GlasgowDaikin Airconditioning UK Limited

Unit 2, Glasgow Airport Business Park,

Marchburn Drive, Paisley PA3 2SJ

1

3

4

5

2

To book a place on one of the customised product training courses please go to Daikin’s new booking site: www.daikintraining.co.uk

Please note: places can only be booked via the website booking system.

Daikin UK’s customised product training

Designed to raise standards, set industry benchmarks and help you develop both product and service expertise.You’llreceivethehighestqualitytrainingandhandsoninstructionatourindustryleadingtechnology centres.

Page 121: Daikin AC Price List 2013

Price List 2013 119

Mis

cella

neou

s

With Daikin UK’s support, specialist further education colleges around the UK are offering high-class training with state-of-the-art equipment. We are committed to helping raise industry standards, for the highly skilled engineers who are in increasing demand.

Growth together

Daikin UK is committed to ensuring that the next generation of heating, air conditioning and ventilation engineers has the specialist skills and practical experience required to install and maintain the innovative new technologies that can improve the performance of HVAC-R systems while reducing their environmental impact.

In turn, this will help employers who invest in apprenticeships and ongoing training of their engineers to capitalise on the growing business opportunities for companies with proven expertise in delivering highly energy-efficient climate control systems.

why invest in training on the latest systems:

>Therapidlygrowingmarketinheatpumpsandheatreclaimsystems offers major new business opportunities

>Newtechnologiesrequirewiderknowledgeofheating,refrigeration and safe handling techniques

>Tighterregulationsdemandcertifiedskillsandrenewalofexisting certifications

>Specialisttrainingprogrammesprovideinvaluablehands-onexperience in the very latest technologies

>Marketleadingtechnologywithinaspecialisttrainingcourseprovides the best grounding to develop your team’s expertise

college collaborations

So far, this ongoing initiative has created the following collaborations with Daikin UK:

City of Bath College

College of North West London

Dudley College

West Suffolk College

PGL Training, Exeter

Courses now available around the UK

1

2

3

4

5

Each college offers carefully prepared training courses. For more information, please contact your local college directly.

Page 122: Daikin AC Price List 2013

Integrated Solutions

Mis

cella

neou

s

120

Daikin Airconditioning UK Ltd are a supplier of air conditioning equipment. The prices shown within this trade price list are for use by qualified installers who agree that:

1 Any equipment purchased is installed by suitably qualified engineers and to the standards expected by Daikin all in accordance with Daikin installation instructions.

2 The purchasing installer is able to maintain, troubleshoot and carry out warranty repairs in accordance with the Daikin Airconditioning warranty policy.

Terms and Conditions

All prices shown within this price list are £0.00 net exclusive of VAT and are subject to our standard terms and conditions which can be found at the back of this price list, and can also be accessed from our website.

Specifications are subject to change without prior notice.

1. Definitions

“Seller”meansDaikinAirconditioningUKLimited,registeredinEnglandandWaleswithcompany number 04616794 trading as Daikin Airconditioning UK Ltd, and shall be construed where applicable to include all employees, agents and subcontractors of that company;

“Buyer”meanstheperson,partnershiporcompanypurchasingtheGoodsfromtheSeller;

“Goods”meanstheplant,machinery,materials,itemsandlabourtobesuppliedbytheSeller subject to this Conditions; and

“Site”meanssuchplacetowhichtheBuyershallrequesttheSellertomakedelivery.

2. Governing Conditions

2.1 All orders, however made, are accepted only upon these Conditions which shall override any terms or conditions incorporated or referred to by the Buyer in writing, orally or otherwise. No variation of these Conditions shall be incorporated into the contract between the Seller and the Buyer unless expressly accepted in writing by a director of the Seller.

2.2 No failure by the Seller to object to any terms or conditions incorporated or referred to by the Buyer in writing, orally or otherwise shall be deemed a waiver of these Conditions or an acceptance of the Buyer’s terms and conditions.

2.3 The Buyer acknowledges that these Conditions together with the express terms of the contract constitute and form the entire terms of this contract to the exclusion of any antecedent statement or representation whether oral, written or implied or whether contained in any advertisement particulars or other matters issued or in any correspondence entered into by the Seller. The Buyer further acknowledges that it has not entered into this contract in reliance upon any such statement or representation, other than the written specifications given by the Seller.

3. Placing Orders

3.1 Placing an order presumes knowledge and acceptance of these Conditions. Upon placing an order the Buyer shall receive an acknowledgement of the order in writing and/or through the online order system designated by Seller, if any; which does not constitute a binding contract until the Seller accepts the Buyer’s order by written confirmation and/or through such online system, as the case may be.

3.2 The Seller reserves the right to reject cancellation by the Buyer of an accepted order or any portion thereof. Cancellation of an accepted order needs to be approved in writing or through the online system designated by Seller, as the case may be by the Seller and the Buyer may be charged cancellation charges. Goods already delivered cannot be returned or exchanged and will be invoiced.

3.3 Changes to an accepted order shall be treated as a separate order, unless otherwise agreed in writing by the Seller. If any changes are made to an original order, the price, discount on or delivery date of that order are subject to change.

3.4 The Seller has a policy of continuous technical improvement and accordingly reserves the right to make minor modifications to the technical specification and design of the Goods. Catalogues and similar publications are only sent by way of information and any technical information provided is an approximate guide. The Seller has no liability for any deviations from or mistakes in such information or for any errors of interpretation.

4. Price and Payment

4.1 The Seller’s quotation, unless previously withdrawn or revised in writing or through the online system designated by Seller, as the case may be, is valid until the end of the financial year (31st March) (after which time it shall automatically expire) and is subject to the Seller’s acceptance of the Buyer’s order. The Seller reserves the right to amend their prices during the financial year and any such changes will mean previous quotations (prior to the price change) are only valid for 30 days, from the date of the quotation.

4.2 The Seller’s quotation includes only such goods, accessories and work as are specified thereon and (without limitation to the foregoing) does not include the cost of lighting, power, heat and water required and/or used during the installation and testing of the Goods at the Site, or any insurance or overtime working by the Seller.

4.3 The price quoted for the Goods is based on the cost to the Seller at the date of quotation of materials, labour, transport and all other expenses and of conforming to any statutory regulations. The Seller reserves the right to vary the quoted price to take account of any variation (including variations caused by alterations in rates of exchange) in the aforesaid costs between the date of the quotation and the date of actual physical delivery of the Goods.

4.4 All amounts stated in these Conditions to be payable by the Buyer are exclusive of Value Added Tax or any similar tax properly chargeable in respect of supplies under these Conditions and any other tax or duty and Buyer will pay all such Value Added Tax and other applicable taxes together with those amounts.

4.5 Each payment made by the Buyer must be calculated and made without, and free and clear of any deduction for set-off or counterclaim and any withholding for or on account of any tax or any other deduction, unless required by law, in which case the Buyer shall ensure that the withholding or deduction does not exceed the minimum amount required by law and shall increase the amount payable by it so that the net amount received and retained by the Seller will equal the full amount which Seller would have received and retained if no withholding or deduction had been made.

4.6 Unless otherwise agreed in writing, the Buyer shall pay the invoice amount of the Goods and any other costs, charges or expenses provided for by these Conditions including Value Added Tax at the then current rate within 30 days from the date of the Seller’s invoice in immediately available funds, but the Seller reserves the right to require payment before delivery or installation.

4.7 Time for payment shall be of the essence of the contract. Any invoice not paid in accordance with the foregoing shall be liable to interest on the unpaid amount thereof at the rate of 3% per annum above the base rate from time to time of Barclays Bank plc calculated on a day to day basis.

5. Delivery

5.1 Failure by the Seller to make delivery on any particular date shall not entitle the Buyer either to cancel the order or the delivery or to repudiate this contract or to claim for any expenses, loss of profit, or any other consequential loss or damage whatsoever.

5.2 If the contract provides for the Seller to deliver the Goods, delivery shall be deemed to take place when the Goods arrive at the agreed destination or are ready for despatch by the Seller to the order of the Buyer and such despatch shall have been delayed by the Buyer, whichever is the sooner.

5.3 The Buyer undertakes that the Site will at all times be safe for the Seller and its vehicles carrying out delivery. The Buyer is responsible, at its own cost, for the provision of such labour and apparatus as is necessary for the offloading and positioning of the Goods on Site and shall give the Seller every assistance in effecting delivery.

5.4 If the contract provides for the Goods to be collected by or on behalf of the Buyer, the Seller shall give the Buyer reasonable notice in writing and/or orally of when and where Goods will be ready for collection. Delivery shall be deemed to take place upon the date and at the place so notified whether or not the Goods are so collected.

5.5 The Seller may deliver the Goods in instalments and each such instalment shall be deemed to be the subject of a separate contract and no damage, non-delivery or shortage in relation to any such instalment shall entitle the Buyer to any remedies in relation to any other instalment or contract. If payment of any instalment is not made in accordance with clause 4, the Buyer shall be liable to the Seller for any costs incurred in connection with manufactured or partly manufactured Goods acquired by the Seller for the Buyer, in addition to the other rights and remedies available to the Seller.

Page 123: Daikin AC Price List 2013

Price List 2013 121

Mis

cella

neou

s

6. Risk

6.1 Risk shall pass to the Buyer on delivery of the Goods.

6.2 If delivery does not take place as a result of any act or omission of the Buyer or if the Buyer fails to collect the Goods as set out in clause 5, then delivery shall be deemed to have taken place and risk shall pass to the Buyer, who shall indemnify the Seller in full against any expense, cost or loss incurred by the Seller including, without limitation, storage and transport costs.

6.3 The Buyer shall examine any Goods delivered upon delivery. If the Goods or any part thereof are received in a damaged condition or are not received, the Seller will accept no responsibility for such damage and or loss unless the Buyer advises the Seller in writing of the damage or loss within 3 working days from the earlier date of actual physical delivery of the Goods or the date of installation of the Goods (save where the damage is a latent defect in the Goods in which case clause 17 shall apply). The Buyer must then afford the Seller reasonable opportunity to inspect any damage or verify any loss and shall immediately return the damaged Goods to Seller.

6.4 The Seller’s sole responsibility upon any damage or loss is to repair or replace the Goods which prove to be lost or defective (or at the Seller’s option the defective part(s)), as soon as is reasonably practicable, provided that they are returned to the Seller by the Buyer. Whether the remedy is repair or replacement shall be at the option of the Seller and such repair or replacement shall be free of charge. Subject to the provisions of clause 17 the Seller shall have no further liability to the Buyer.

6.5 If the Buyer shall fail to comply with clause 6.3, the Goods shall be deemed to be in accordance with the contract and the Buyer shall be bound to accept delivery and shall make payment without any deduction in accordance with these Conditions.

6.6 The Seller will not be liable for any claims resulting from loss or damage to the Goods occurring after delivery.

7. Force Majeure

7.1 If the Seller is prevented from performing the contract by any cause beyond its reasonable control, however arising, then it may by written notice to the Buyer determine the contract.

7.2 In such event, the Buyer shall pay to the Seller all reasonable costs incurred by the Seller at the date of such notice in relation to its partial and or attempted performance of its obligations hereunder but, subject thereto, neither the Seller nor the Buyer shall be under any liability whatsoever to the other in connection with the contract.

8. Shortages

If the Seller is unable, for any reason, to supply the total demand for Goods of the contract description, the Seller may allocate its available supply of such Goods among any and all Buyers on such basis as the Seller may deem fair and practical without liability for any failure of performance which may result. The Buyer shall not be entitled to reject such Goods for short delivery.

9. Works and Specification

9.1 Where existing equipment is to be used in connection with the Goods, the Buyer shall be fully and solely responsible for it.

9.2 Any adaptation of the standard specification of the Goods shall be made upon the full and sole liability of the Buyer. Where the standard specification of the Goods is adapted, whether by the Seller at the request of the Buyer, or by the Buyer itself, the Buyer agrees to indemnify (and shall keep so indemnified) the Seller in full against any claim resulting from any such variation (whether or not arising out of the negligence of the Seller, its servants, agents or subcontractors). In the event of any adaptation made by the Seller upon request of the Buyer, the Buyer shall make such payment in respect thereof as the Seller may reasonably demand.

9.3 The Buyer shall be responsible for ensuring that the Goods are sufficient and suitable for the Buyer’s purposes (whether such Goods have been adapted from their standard specification or not) and the Seller shall have no liability to the Buyer in the event that the Goods are not sufficient and suitable for the Buyer’s purposes.

9.4 Unless otherwise expressly agreed in writing, the Seller shall not be responsible for any errors, omissions or defects in any goods, equipment, machines, parts, drawings, designs, specifications, test results, reports or other information supplied to the Seller by the Buyer or the Buyer’s employees, agents, sub-contractors or representatives and the Buyer agrees to indemnify and keep indemnified the Seller against all claims and liabilities incurred by the Seller resulting from such errors, omissions or defects.

10. Installation

It is the responsibility of the Buyer to install and commission the Goods and to ensure its employees, agents and subcontractors or any other persons used by the Buyer to install and commission the Goods are fully trained to do so and that the terms of any instructions or manuals provided with the Goods are followed.

11. Health and Safety

The Buyer shall ensure that all Goods shall be used strictly in accordance with any relevant information, instructions or advice which the Seller or the manufacturer of the Goods may make available with or in connection with the Goods.

12. Environmental

12.1 The Buyer shall be responsible for all costs, charges, and expenses arising from or in connection with the decommissioning, recovery, recycling, and disposal of all or part of the Goods and shall not seek to recover such expenses or contribution from the Seller.

12.2 The Buyer is responsible for obtaining and complying with all relevant licenses, permissions, permits and consents from appropriate regulatory bodies and for complying with any other lawful authority in connection with the storage, installation, operation, use, maintenance, repair, transportation, decommissioning, recovery and eventual disposal of the Goods.

12.3 Where the Buyer sells all or part of the Goods to another party, the Buyer shall enter into a similar covenant with that party.

13. Reservation of Title

13.1 Notwithstanding the provisions of clause 6 and the passing of risk in the Goods to the Buyer, the Seller retains ownership of the Goods the property in which shall not pass to the Buyer and the Buyer shall keep any Goods delivered to it as the bailee for and on behalf of the Seller until the Seller has received payment of the price of all of the Goods then agreed to be sold by the Seller to the Buyer pursuant to these Conditions, and until such time the Buyer:

(a) shall keep and retain the Goods free from any charge, lien or other encumbrance, shall insure them for their full replacement value against any loss or damage and shall keep them properly stored and protected; and

(b) shall store the Goods separately or in some other way ensure that they are readily identifiable as the property of the Seller and irrevocably authorises the Seller’s representatives to enter upon the Buyer’s premises where the Goods are or are thought by the Seller to be stored for the purpose of repossessing them and subsequently reselling them.

13.2 Notwithstanding the provisions of clause 13.1, provided that none of the circumstances set out in clause 16 shall apply, the Buyer shall be entitled before the Seller has received full payment of the price of the Goods to offer for sale and sell the Goods in the ordinary course of its business (but not otherwise) and the proceeds of such sale or the Buyer’s claim for such proceeds shall be held by the Buyer as agent for the Seller and the Seller’s property in the Goods shall be transferred to the proceeds of such resale or the claim for such proceeds and shall attach thereto until the Seller has received payment of the price of all of the Goods then agreed to be sold by the Seller to the Buyer pursuant to these Conditions.

13.3 Save as otherwise stated therein, the provisions of clauses 13.1 and 13.2 shall survive the termination of any contract made pursuant to these Conditions for whatever reason and in particular, but without limitation, termination by the Seller by the acceptance of repudiation of this contract by the Buyer.

14. Intellectual Property Rights

14.1 The Buyer shall have no rights to any intellectual property owned by or licensed to the Seller. The Buyer shall not allow any trademark or instruction or warning applied to the Goods to be obliterated or obscured.

14.2 All designs, samples, models, experimental equipment, marketing devices, accessories and other items relating to the Goods or their development or creation shall remain the Seller’s property, shall be treated as confidential and shall not be copied, reproduced or disclosed to any person without the Seller’s prior written consent.

15. Confidentiality

15.1 All information and/or advice, whether written or oral, whether in relation to the Goods or to the business of Seller, given by the Seller to the Buyer, shall not be disclosed to any third party without the prior written consent of the Seller, save to the extent that such information and/or advice is in the public domain otherwise than by virtue of a breach of this condition or that the disclosure is required by law.

15.2 The Buyer shall promptly give notice to the Seller of any disclosure required by law and the Seller may seek an appropriate remedy to prevent such disclosure. The Buyer undertakes to fully co-operate with the Seller (at the Buyer’s expense) if the Seller rejects the validity of such a requirement.

16. Early Termination

16.1 This clause applies if:

(a) the Buyer makes any voluntary arrangement with its creditors or becomes subject to an administration order or (being an individual or firm) becomes bankrupt or (being a company) goes into liquidation (otherwise than bona fide for the purposes of amalgamation or reconstruction); or

(b) an encumbrancer takes possession, or a receiver is appointed, of any of the property or assets of the Buyer; or

(c) the Buyer ceases, or threatens to cease, to carry on business; or

(d) any event analogous to any of the foregoing occurs in any jurisdiction in relation to the Buyer; or

(e) the Buyer commits any default or breach of the terms of this contract or of any of its obligations to the Seller including, without limitation, failure to make payment when due; or

Page 124: Daikin AC Price List 2013

Integrated Solutions

Mis

cella

neou

s

122

(f ) the Seller reasonably apprehends that any of the events mentioned above is about to occur in relation to the Buyer and notifies the Buyer accordingly.

16.2 If this clause applies then, without prejudice to any other right or remedy available to the Seller, the Seller shall be entitled to cancel any contract made pursuant to these Conditions or suspend any further deliveries of the Goods without any liability on its part, and if the Goods have been delivered but not paid for, the price shall become immediately due and payable notwithstanding any previous agreement or arrangement to the contrary.

17. Warranties and Liability

17.1 Subject to clause 17.3 and unless otherwise agreed in writing, the Goods are guaranteed under manufacturers’ warranty for a period of 1 year upon delivery. This warranty is limited to the repair or replacement ex factory of the parts found defective. Unless otherwise agreed in writing, the Seller shall not be liable for repayment of replacement costs nor for any incidental, consequential or special damages.

17.2 To claim under the warranty, the Buyer shall submit to the Seller adequate proof that the Goods are defective, as required by the Seller. Unless otherwise agreed in writing, claims with regard to the Goods will only be accepted if they are notified within 12 months after delivery of the Goods.

17.3 This warranty is given on condition that the maintenance of the Goods has been carried out in accordance with the manufacturers’ instructions by an authorised Daikin dealer/installer/maintenance company.

17.4 The warranty referred to in clause 17.1 does not apply if:

(a) the Goods have been modified by the Buyer;

(b) the Goods have been incorrectly installed by the Buyer;

(c) defects in the Goods have been caused by the act, neglect, omission or default of the Buyer or any third party, fair wear and tear or abnormal working conditions;

(d) any remedial work in respect of the Goods has been carried out by third parties instructed by the Buyer without the prior written approval of the Seller including, but not limited to, servicing, alteration and repair of the Goods;

(e) if the Seller’s installation and operation instructions (if any) and any instructions issued by the manufacturer, are not followed.

17.5 The Seller only acts in its capacity as seller and not as an installer or consultant and the Seller is not responsible for advice given by its representatives concerning the installation of the Goods, save in relation to all or any part of the Goods which the Seller has installed with the written agreement of an authorised representative of the Seller (excluding any agent or subcontractor of the Seller) to the installation and to the terms of such installation for claims.

17.6 Save for liability for death or personal injury due to the negligence of the Seller and liability under the Consumer Protection Act 1987, the Seller shall not be liable to the Buyer:

(a) for any damage to persons or property, however arising;

(b) for defects, in or in any way connected with the Goods, caused by the act, neglect, omission or default of the Buyer or any third party, fair wear and tear or abnormal working conditions;

(c) for any remedial work in respect of the Goods, carried out by third parties instructed by the Buyer without the prior written approval of the Seller including, but not limited to, servicing, alteration and repair of the Goods;

(d) for claims if the Seller’s installation and operation instructions (if any) and any instructions issued by the manufacturer, are not followed. The Seller reserves the right to charge for remedial works in these circumstances;

(e) possible defects in manufacturing the Goods or the conception of the raw materials used;

(f ) for any other defects in the Goods not falling within paragraphs (a) to (e) of this clause, unless notified to the Seller by the earlier of 14 days of delivery of the Goods or installation of the Goods or occurrence of a malfunction by a latent defect; and

(g) for any special, indirect, consequential or economic loss (howsoever arising) including, but not limited to, loss of profit, loss of production, loss of business.

17.7 Save for liability for death or personal injury due to the negligence of the Seller and liability under the Consumer Protection Act 1987, the Seller’s aggregate liability to the Buyer in respect of any occurrence or series of occurrences attributable to the same cause, whether for negligence, breach of contract, misrepresentation or otherwise, shall in no circumstances exceed the price paid by the Buyer to the Seller in respect of the Goods in question.

17.8 The Seller’s prices are determined on the basis of the limits of liability set out in this clause 17. The Buyer may by written notice to the Seller request the Seller to agree a higher limit of liability provided insurance cover can be obtained therefor. The premiums in respect of insurance up to such higher limit will be for the account of the Buyer.

17.9 Subject as expressly provided in these Conditions, all warranties, conditions or other terms implied by statute, common law, custom of the trade, course of dealing or otherwise, including, for the avoidance of doubt, all warranties implied by the Sale of Goods Act 1979, are excluded to the fullest extent permitted by law.

17.10 The Buyer’s remedy in respect of any claim for which the Seller is liable in terms hereof shall be limited to, at the sole option of the Seller, repair or replacement of the item in question or refund of the purchase price (if paid).

17.11 The Buyer shall not be entitled to exercise a right of retention, or withhold payment of any amount payable under the contract to the Seller because of any disputed claim of the Buyer in respect of the Goods or any other alleged breach of the contract, or to set-off any amount payable under the contract to the Seller against any monies not then presently payable by the Seller or for which the Seller disputes liability, or to return Goods to the Seller unless authorised in writing by a director of the Seller.

17.12 The Seller shall not be liable to the Buyer (including, but without limitation, in negligence) or be deemed to be in breach of contract by reason of any delay in performing, or any failure to perform, any of the Seller’s obligations in relation to the Goods, if the delay or failure was due to any cause beyond the Seller’s reasonable control.

17.13 The Buyer shall indemnify the Seller against all claims (including the cost of any legal proceedings) for the death of or injury to any person or for the damage to or loss of any property made by any person against the Seller either under any statute or at common law which may arise out of or be in any way connected with the execution of the contracted works or the installation, operation or use of the Goods except where the same is due to the negligence, omission or default of the Seller.

18. Personal Data

18.1 We will only use any personal data we obtain about you in accordance with the Data Protection Act 1998. We may use your personal data for the purposes of fulfilling your order, providing goods and services to you, managing our relationship with you, for our internal accounting and processes and for legal or regulatory purposes. For some of these purposes we may need to share your data with third parties but we always ensure that your data is kept confidential and protected by third parties. In particular, we may ask credit reference agencies to run credit searches or checks against you and those registered at your address and we may pass on your information to these agencies to assess your financial performance, including sharing our customer ledgerbalances.Youshouldbeawarethattheresultsofthecreditsearchesorchecksmay be added to your credit reference file.

18.2 Sometimes, we may need to transfer your data outside the European Economic Area to countries which do not have as strong data protection laws as the UK. Where we do so, we take steps to ensure that your data is protected to the same standard as in the UK.

18.3Youagreethatweandothermembersofourgroupand/orselectedthirdpartiesmay contact you by phone, e-mail or SMS or other messaging service about other products and services which may be of interest to you. If you do not want to receive such messages at any time, please let us know and you will no longer be contacted.

19. General

19.1 The invalidity or unenforceability for any reason of any terms of these Conditions shall not prejudice or affect the validity or enforceability of the remainder.

19.2 The Buyer shall not be entitled, without the prior consent in writing of the Seller, to assign its rights under the contract.

19.3 Any notice required or permitted to be given under these Conditions shall be in writing and shall be sent by recorded delivery addressed to that other party at its registered office or principal place of business or such other address as may at the relevant time have been notified pursuant to this provision to the party giving notice. In proving service it shall be sufficient to prove that the notice was properly addressed and posted.

19.4 No waiver by the Seller of any of the terms of these Conditions shall release the Buyer from full performance of the remaining terms, and no waiver by the Seller of any breach of the terms of these Conditions shall be a waiver of any subsequent breach of the same or any other term of this Conditions. No failure to exercise, nor delay or omission by the Seller in exercising, any right, power or remedy conferred on it under these Conditions or provided by law shall except with the express written consent of that party affect that right, power or remedy; or operate as a waiver of it.

19.5 If any order is made by two or more Buyers jointly, the obligations of those Buyers under the contract shall be joint and several.

19.6 This Contract shall be governed by and construed in accordance with the laws of England and any dispute shall be referred to the exclusive jurisdiction of the English Courts.

19.7 The Seller and the Buyer do not intend that any provision of these Conditions shall be enforceable by virtue of the Contract (Rights of Third Parties) Act 1999 by any person who is not a party to the contract.

19.8 We reserve the right, at our sole discretion, to change, modify or otherwise alter these terms and conditions at any time. Such modifications shall become effective immediately.

Page 125: Daikin AC Price List 2013

your comfort. our world.

Daikin Airconditioning UK Limited The Heights Brooklands Weybridge Surrey KT13 0NY Tel 0845 6419000 Fax 0845 6419009 www.daikin.co.uk

UKE

PCEN

13-9

11 /

04.

13 /

Des

ignH

Q. C

opyr

ight

201

3 D

aiki

nPr

inte

d in

the

UK

on F

SC c

ertif

ied

pape

r fro

m s

usta

inab

le s

ourc

es.

Visit www.eca.gov.uk/etl and type ‘Daikin’ in the quick search box for details of the latest ECA qualifying Daikin units

Daikin products are distributed by:The present catalogue is drawn up by way of information only and does

not constitute an offer binding upon Daikin UK. Daikin UK has compiled the

content of this catalogue to the best of its knowledge. No express or implied

warranty is given for the completeness, accuracy, reliability or fitness for

particular purpose of its content and the products and services presented

therein. Specifications are subject to change without prior notice. Daikin UK

explicitly rejects any liability for any direct or indirect damage, in the broadest

sense, arising from or related to the use and/or interpretation of this catalogue.

All content is copyrighted by Daikin UK.

Daikin units comply with the European regulations that guarantee the safety of the product.

Scotland Region

0845 641 9330

Northern Region

0845 641 9340

Midlands Region

0845 641 9370

Western Region

0845 641 9320

North London

0845 641 9360

South London

0845 641 9355

FSCCarbon

Balanced Paper