D Clock R Op Man 06 03 12 - Amazon S3 · D-Clock-R DMS-6 DUAL REDUNDANT WORD CLOCK DISTRIBUTION...

9
DRAWMER D-Clock-R DMS-6 DUAL REDUNDANT WORD CLOCK DISTRIBUTION AMPLIFIER CONTENTS Warranty Safety Consideration Radio Frequencies Statement Chapter 1 - Introduction Introduction Features Overlay Installation Power Connection Chapter 2 - Control Description Simple Connection Guide Audio Connections Control Description Chapter 3 - DMS-6 General Information If a fault develops Contacting Drawmer Specification Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Transcript of D Clock R Op Man 06 03 12 - Amazon S3 · D-Clock-R DMS-6 DUAL REDUNDANT WORD CLOCK DISTRIBUTION...

Page 1: D Clock R Op Man 06 03 12 - Amazon S3 · D-Clock-R DMS-6 DUAL REDUNDANT WORD CLOCK DISTRIBUTION AMPLIFIER Expanding on the renowned Drawmer D-Clock in providing word clock measurement

DRAWMERD-Clock-R

DMS-6DUAL REDUNDANT

WORD CLOCKDISTRIBUTION AMPLIFIER

CONTENTSWarrantySafety ConsiderationRadio Frequencies Statement

Chapter 1 - IntroductionIntroductionFeatures OverlayInstallationPower Connection

Chapter 2 - Control DescriptionSimple Connection GuideAudio ConnectionsControl Description

Chapter 3 - DMS-6 General InformationIf a fault developsContacting DrawmerSpecificationBlock Diagram

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Page 2: D Clock R Op Man 06 03 12 - Amazon S3 · D-Clock-R DMS-6 DUAL REDUNDANT WORD CLOCK DISTRIBUTION AMPLIFIER Expanding on the renowned Drawmer D-Clock in providing word clock measurement

2

Drawmer Electronics Ltd., warrants the Drawmer DMS-6D-Clock-R Dual Redundant Word-Clock DistributionAmplifier to conform substantially to the specifications ofthis manual for a period of one year from the original dateof purchase when used in accordance with thespecifications detailed in this manual. In the case of a validwarranty claim, your sole and exclusive remedy andDrawmer’s entire liability under any theory of liability willbe to, at Drawmer’s discretion, repair or replace the productwithout charge, or, if not possible, to refund the purchaseprice to you. This warranty is not transferable. It appliesonly to the original purchaser of the product.

For warranty service please call your local Drawmer dealer.Alternatively you can call Drawmer Electronics Ltd. directlyat +44 (0)1709 527574. Then ship the defective product,with transportation and insurance charges pre-paid, toDrawmer Electronics Ltd., Coleman Street, Parkgate,Rotherham, S62 6EL UK. Write the RA number in largeletters in a prominent position on the shipping box. Encloseyour name, address, telephone number, copy of the originalsales invoice and a detailed description of the problem.Drawmer will not accept responsibility for loss or damageduring transit.

This warranty is void if the product has been damaged bymisuse, modification or unauthorised repair.

THIS WARRANTY IS IN LIEU OF ALL WARRANTIES,WHETHER ORAL OR WRITTEN, EXPRESSED, IMPLIEDOR STATUTORY. DRAWMER MAKES NO OTHERWARRANTY EITHER EXPRESS OR IMPLIED,INCLUDING, WITHOUT LIMITATION, ANY IMPLIEDWARRANTIES OF MERCHANTABILITY, FITNESS FORA PARTICULAR PURPOSE, OR NON-INFRINGEMENT.PURCHASER’S SOLE AND EXCLUSIVE REMEDYUNDER THIS WARRANTY SHALL BE REPAIR ORREPLACEMENT AS SPECIFIED HEREIN.

IN NO EVENT WILL DRAWMER ELECTRONICS LTD. BELIABLE FOR ANY DIRECT, INDIRECT, SPECIAL,INCIDENTAL OR CONSEQUENTIAL DAMAGESRESULTING FROM ANY DEFECT IN THE PRODUCT,INCLUDING LOST PROFITS, DAMAGE TO PROPERTY,AND, TO THE EXTENT PERMITTED BY LAW, DAMAGEFOR PERSONAL INJURY, EVEN IF DRAWMER HASBEEN ADVISED OF THE POSSIBILITY OF SUCHDAMAGES.

Some states and specific countries do not allow theexclusion of implied warranties or limitations on how longan implied warranty may last, so the above limitations maynot apply to you. This warranty gives you specific legalrights. You may have additional rights that vary from stateto state, and country to country.

In the interests of product development, Drawmer reserve the right to modify orimprove specifications of this product at any time, without prior notice.

ONE YEAR LIMITED WARRANTY

COPYRIGHTThis manual is copyrighted 8 2012 by Drawmer Electronics Ltd. With all rights reserved. Under copyrightlaws, no part of this publication may be reproduced, transmitted, stored in a retrieval system or translatedinto any language in any form by any means, mechanical, optical, electronic, recording, or otherwise, with-out the written permission of Drawmer Electronics Ltd.

Page 3: D Clock R Op Man 06 03 12 - Amazon S3 · D-Clock-R DMS-6 DUAL REDUNDANT WORD CLOCK DISTRIBUTION AMPLIFIER Expanding on the renowned Drawmer D-Clock in providing word clock measurement

3

For the USA

FEDERAL COMMUNICATIONS COMMISSION RADIOFREQUENCY INTERFERENCE STATEMENT

This equipment has been tested and found to comply withthe limits for a Class B digital device, pursuant to Part 15of the FCC Rules. These limits are designed to providereasonable protection against harmful interference in a resi-dential installation. This equipment generates, uses andcan radiate radio frequency energy and, if not installed andused in accordance with the instructions, may cause harm-ful interference to radio communications. However, thereis no guarantee that interference will not occur in a particu-lar installation. If this equipment does cause interferenceto radio or television reception, which can be determinedby turning the equipment off and on, then the user is en-couraged to try to correct the interference by one or moreof the following measures:

Re-orient or relocate the receiving antenna.

Increase the separation between the equipment andthe receiver.

Connect the equipment into an outlet on a circuitdifferent from that to which the receiver is connected.

Consult the dealer or an experienced radio/TVtechnician for help.

Unauthorised changes or modification to this system canvoid the users’ authority to operate this equipment.This equipment requires shielded interface cables in orderto meet FCC class B limit.

For Canada

CLASS B NOTICEThis digital apparatus does not exceed the Class B limitsfor radio noise emissions set out in the Radio InterferenceRegulations of the Canadian Department of Communica-tions.

CLASSE B AVISCet appareil numérique ne dépasse pas les limites de laclasse B au niveau des émissions de bruits radioélectriquesfixés dans le Règlement des signaux parasites par leministère Canadien des Communications.

DRAWMERD-Clock-R

DMS-6DUAL REDUNDANT WORD CLOCK

DISTRIBUTION AMPLIFIER

SAFETY CONSIDERATIONS

CAUTION - MAINS FUSE

TO REDUCE THE RISK OF FIREREPLACE THE MAINS FUSES ONLY WITHA FUSE THAT CONFORMS TO IEC127-2.250 VOLT WORKING, TIME DELAY TYPE

AND BODY SIZE OF 20mm x 5mm.THE MAINS INPUT FUSE MUST

BE RATED AT T500mA.

CAUTION - MAINS CABLESDO NOT ATTEMPT TO CHANGE

OR TAMPER WITH THESUPPLIED MAINS CABLES.

CAUTION - SERVICINGDO NOT PERFORM ANY SERVICING.

REFER ALL SERVICING TO QUALIFIEDSERVICE PERSONNEL.

WARNINGTO REDUCE THE RISK OF FIRE OR

ELECTRIC SHOCK DO NOT EXPOSETHIS EQUIPMENT TO RAIN OR MOISTURE.

Page 4: D Clock R Op Man 06 03 12 - Amazon S3 · D-Clock-R DMS-6 DUAL REDUNDANT WORD CLOCK DISTRIBUTION AMPLIFIER Expanding on the renowned Drawmer D-Clock in providing word clock measurement

4

DRAWMERD-ClocD-ClocD-ClocD-ClocD-Clockkkkk-R-R-R-R-R

DMS-6DUAL REDUNDANT WORD CLOCK DISTRIBUTION AMPLIFIER

Expanding on the renowned Drawmer D-Clock in providingword clock measurement and distribution to digital audioenvironments the D-Clock-R has been designed with notonly studio recording in mind but also the live and broadcastenvironment, where reliability and stability are absolutelyimperative. Designed for fail-safe operation the D-Clock-Ras been developed with dual redundancy for both thepower supplies and also the word clock inputs, ensuringthat the show will go on regardless of technical difficulties.

The Drawmer D-CLock-R is an auto-sensing dualredundancy input, sixteen output word clock distributorwith a 16 character blue LCD display providing a highaccuracy reference measurement of the incoming samplerate. It uses a high stability TCXO (temperaturecompensated xtal oscillator) along with a microcontrollerto measure the incoming sample rate to an accuracy of2ppm and displays the information in three differentformats, actual frequency (to one decimal place), nominalfrequency +/- ppm error, or nominal frequency pluspercentage of pull up or pull down.

The D-Clock-R has two BNC inputs, a defaultand auxiliary, which is automatically selecteddepending on the strength and quality of thesignal, and capable of locking on to bothword clock (upto 768KHz) and AES-3id (upto192kHz), it has twelve BNC clock outputssituated on the rear panel with a further fourBNC clock outputs on the front panel forquick patching to other digital devices.

CHAPTER 1

INTRODUCTION

Dual Redundancy power supply via 2 xUniversal voltage filtered mains powerinlets for continuous operation & reliability.

Dual Redundant input / 16 output ClockMeasurement and Distribution Amplifier

Inputs: 2 x Auto-Sensing WordClock /AES3id BNC dual redundant inputs (@75Ohms impedance) - should one fail inputis automatically switched to the alternativesource.

Outputs: 16 BNC clock outputs - 33 Ohmsimpedance - 4 on the front panel forconvenience.

3 sample rate measurement LCD modesaccurate to 2ppm.

DUAL REDUNDANT INPUTSAuto-Sensing, auto-switching

inputs provides a fail-safe backupshould one input fail.

TWO INDEPENDENT POWER SUPPLIESPROVIDE DUAL REDUNDANCY

Can fully operate on a single supply or both (with power loadbalancing), providing a fail-safe backup should one fail.

Page 5: D Clock R Op Man 06 03 12 - Amazon S3 · D-Clock-R DMS-6 DUAL REDUNDANT WORD CLOCK DISTRIBUTION AMPLIFIER Expanding on the renowned Drawmer D-Clock in providing word clock measurement

5

7

6

4x Front Panel Outputs:4x BNC output connectors mountedon the front for ease of connectivity.

1 2 3 4 5

8

1 Display:Blue/White liquid crystal displaywith three switchable modes ofoperation.

2 Display Mode:Switch to control the mode ofdisplay 2 between Frequency,PPM and %.

3

Clock Present LED’s:Show the presence of Word Clockand AES3id for both SYNC1 andSYNC2 inputs 7

4 Active Input LED’s:Two led’s showing which of the twoword clock inputs 7 has beenautomatically selected.

5

2x Auto Sensing Word-Clock/AES3id Inputs:2 Dual Redundant BNC Word Clock/ AES3id inputs can be connectedsimultaneously to provide a clockand also a backup, should one fail.The input selection is carried outautomatically by the DMS-6, withSYNC 1 being default and SYNC 2auxiliary.

7 12x BNC Clock Outputs:Buffered BNC wordclock outputs with33 Ohms impedance.

8 Dual Redundant PSU Inputs:2 x identical power supplies can beused either simultaneously orindependently, should power to onefail.

9

9

FEATURES OVERLAY

The DMS-6 D-Clock-R is designed for standard 19" rackmounting and occupies 1U of rack space. Avoid mountingthe unit directly above power amplifiers or power suppliesthat radiate significant amounts of heat.If the unit is to be used in a mobile situation, it is strongly

recommended that the rear of the unit is supported in thecarrying rack to avoid bending the front panel rack mounting‘ears’. Use fibre or plastic washers to prevent the front panelbecoming marked by the mounting bolts.Always connect the mains earth to the unit.

INSTALLATION

The DMS-6 D-Clock-R is fitted with two identical andindependent power supply units, providing DualRedundancy. Either can be used solely to supply powerto the unit, but in situations where it is critical that powermust be maintained mains power should be supplied toboth units. With both power supplies receiving power theunits will share the load, however, should either fail, theother is capable of fully driving the unit.

The unit will be supplied with two power cablessuitable for domestic power outlets in your country.For your own safety it is important that you usethese cables. The unit should always be connectedto the mains supply earth using at least one of thesecables.

Powered by dual universal switch mode power supplies,the DMS-6 D-Clock-R operates from mains voltagesbetween 85 - 250v, eliminating the need to make anychanges when touring and allowing the unit to remain fullyoperational during large fluctuations in the mains powersupply.

POWER CONNECTION

Active PSU LED’s:Two led’s showing which of the twoPSU inputs 9 is operational.

6

Page 6: D Clock R Op Man 06 03 12 - Amazon S3 · D-Clock-R DMS-6 DUAL REDUNDANT WORD CLOCK DISTRIBUTION AMPLIFIER Expanding on the renowned Drawmer D-Clock in providing word clock measurement

6

SIMPLE CONNECTION GUIDE

CHAPTER 2

Word Clock / AES-3idUse only good quality 750 digital or video coax (not aerialdownlead) cable for the word-clock signals, terminated withthe correct type of 75Ω BNC connectors - inferior cableswill introduce jitter and will completely undermine theperformance benefits which might be achieved by using amaster clock in the first place!

AES3id calls for unbalanced 75 ohm connections, whichmake its hardware requirements the same as S/PDIFconnections, though AES3id is implemented with BNCconnections instead of RCA type connections. While AES3& AES3id have different hardware transmission methodsthe data contained within the transmission is identical.

AUDIO CONNECTIONS

Page 7: D Clock R Op Man 06 03 12 - Amazon S3 · D-Clock-R DMS-6 DUAL REDUNDANT WORD CLOCK DISTRIBUTION AMPLIFIER Expanding on the renowned Drawmer D-Clock in providing word clock measurement

7

CONTROL DESCRIPTION

DISPLAY A Blue/White LCD display with three switchable modes of operation: FREQ, ±PPM and ±%.The mode that is displayed during power down is saved for the next session.The display accuracy is 2ppm at all sample rates up to 768kHz, or 0.1Hz increments @48KHz sample rate

MODE A switch controls the mode of display enabling you to read the incoming sample rate in yourpreferred manner. Pressing the switch toggles through the three modes of FREQ, ±PPM and±%, with led indication.

FREQ

Displays the actual frequency to four decimalplaces upto >768kHz.

±PPM

Displays the nominal sample rate with +/- ppm(part per million) error indication for 32, 44.1, 48,96 & 192KHz

± %

Displays the nominal sample rate with percentagepull up/down indication for 32, 44.1, 48, 96 &192KHz

The LED’sindicate thestatus of theinput sourcesfor both Sync1& Sync2 inword clock &A E S - 3 i d .

When a led is lit continuously a strong signalis being received by that input source andthe D-Clock-R is “locked on”. If a led flickers,the signal for that particular input sourceis weak or unstable - in this case thesource of this weak signal should belocated and improved.

CLOCK PRESENTThe two LED’sindicate the inputsource beingused - eitherSync1 or Sync2.By default Sync1would be used,however, should

this signal be weak or missingthe D-Clock-R will automaticallyswitch to using Sync2 as theclock input.

ACTIVE INPUTThe two LED’sindicate thepower supplybeing used -either PSU1 orPSU2. With bothLED’s lit thepower is shared

between the two PSU’s. A LEDunlit identifies that the PSU is notin use and the source of thisproblem should be found as soonas it is convenient. The DMS-6can operate via both or either ofthe PSU’s.

ACTIVE PSU

Page 8: D Clock R Op Man 06 03 12 - Amazon S3 · D-Clock-R DMS-6 DUAL REDUNDANT WORD CLOCK DISTRIBUTION AMPLIFIER Expanding on the renowned Drawmer D-Clock in providing word clock measurement

8

IF A FAULT DEVELOPSFor warranty service please call Drawmer Electronics Ltd.or their nearest authorised service facility, giving full detailsof the difficulty.

A list of all main dealers can be found on the Drawmerwebpages.

On receipt of this information, service or shippinginstructions will be forwarded to you.

No equipment should be returned under the warrantywithout prior consent from Drawmer or their authorisedrepresentative.

For service claims under the warranty agreement a serviceReturns Authorisation (RA) number will be issued.Write this RA number in large letters in a prominent positionon the shipping box. Enclose your name, address,telephone number, copy of the original sales invoice and adetailed description of the problem.

Authorised returns should be prepaid and must be insured.

All Drawmer products are packaged in specially designedcontainers for protection. If the unit is to be returned, theoriginal container must be used. If this container is notavailable, then the equipment should be packaged insubstantial shockproof material, capable of withstandingthe handling for the transit.

CONTACTING DRAWMERDrawmer Electronics Ltd., will be pleased to answer allapplication questions to enhance your usage of thisequipment. Please address correspondence to:

Drawmer (Technical Help line)Coleman StreetParkgateRotherhamS62 6ELUK

Alternatively contact us by E-mail on :

[email protected]

Further information on all Drawmer dealers, Authorisedservice departments and other contact information can beobtained from our web pages on:

http://www.drawmer.com

D-Clock-R DMS-6 GENERAL INFORMATION

CHAPTER 3

INPUTSBNC wordclock input Dual 75ohm BNCSensitivity Auto selecting

MAIN OUTPUTSBNC wordclock outputs 16 x simultaneous re-buffered BNC

wordclock outputs with 33 ohmoutput impedance.4 of which are on the front panelfor ease of connectivity.

DISPLAYBlue/white LCD display with three switchable modes ofoperation with mode led indicators for each:

frequency actual frequency up to >768KHz

+/- ppm nominal sample rate with +/- ppmerror indication for 32,44.1,48,96& 192KHz

+/-% Nominal sample rate withpercent pull up/down indicationfor 32,44.1,48,96 & 192KHz

Accuracy 2ppm at all sample rates up to768KHz0.1 Hz increments @ 48KHzsample rate

INDICATORSWordclock/AES-3id clock present led indicatorsActive input led indicatorsPSU active led indicators

GENERALPower Supply: 2 x Internal identical,

Universal Input, 10 Wfor Dual Redundancy

Power Requirement <6W

Fuse Rating T500mA for All voltages.CONFORMING TO:IEC127-2

Fuse Type 20mm x 5mm, Class 3 Slow -Blow. 250Volt working

Dimensions: 1u, 19" Rack Mount, Depth145 mm

Weight 1.7 kg

SPECIFICATION

Page 9: D Clock R Op Man 06 03 12 - Amazon S3 · D-Clock-R DMS-6 DUAL REDUNDANT WORD CLOCK DISTRIBUTION AMPLIFIER Expanding on the renowned Drawmer D-Clock in providing word clock measurement

9

BLOCK DIAGRAM

Ref:1v00 A 06-03-12