    Configuration Planning Worksheetsfor CX3-40c Storage Systems

    August 8, 2007

    This document provides worksheets for you to use in planning theinstallation and configuration of the storage system. These worksheetsassume that you are familiar with the servers (hosts) that will use thestorage systems and with the operating systems on these servers. For eachstorage system that you will configure, complete a copy of the enclosedworksheets.

    For the most current, detailed, and complete CX3-series configuration

    rules and sample configurations, refer to the E-Lab Interoperability

    Navigator on the Powerlink site (http://Powerlink.EMC.com).

    The configuration planning guide for the storage systems provides more

    information on planning your storage-system configuration, and also includes

    copies of these worksheets. You can create a customized version of this documentfrom the user customized documentation link on the Powerlink CLARiiON tools

    page or by viewing the version for your storage system on the documentation and

    resources CD that shipped with your storage system.

    The worksheets in this document are:

    Hardware planning worksheets...... ...... ..... ...... ...... ..... ...... ...... ...... .. 2

    Storage allocation planning worksheets .......................................... 14 Data replication and mobility planning worksheets .. ... ... ... ... ... ... ... .. 24

    1

    http://powerlink.emc.com/http://powerlink.emc.com/http://powerlink.emc.com/http://powerlink.emc.com/
  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    2/36

    Hardware planning worksheetsThis section contains the following worksheets:

    Hardware Components Worksheet, page 2

    iSCSI Target and Initiator Port Network Information Worksheet, page 4

    iSNS Server Worksheet (Windows environment only), page 6

    iSCSI CHAP Authentication Worksheets, page 7

    Storage-System Management Ports Worksheet, page 10

    CLARalert Worksheet, page 12

    Hardware Components Worksheet

    Use the Hardware Components Worksheet in Table 1 and the cableplanning template in Figure 1 to plan the hardware components youwant. Some installation types do not have switches or multiple servers.

    Table 1 Hardware Components Worksheet

    Server information

    Server name: Server operating system:

    Adapters in server:Server name: Server operating system:

    Adapters in server:

    Server name: Server operating system:

    Adapters in server:

    Server name: Server operating system:

    Adapters in server:

    Storage-system components

    SPEs: DAEs: Cabinets:

    Fibre Channel switch information

    32-port: 24-port: 16-port: 8-port:

    2 Configuration Planning Worksheets for CX3-40c Storage Systems

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    3/36

    Cables between server and Fibre Channel switch ports cable A

    Cable A1 (optical) number: Length (m or ft):

    Cable A2 (optical) number: Length (m or ft):

    Cable A3 (optical) number: Length (m or ft):

    Cable A4 (optical) number: Length (m or ft):

    Cables between Fibre Channel switch ports and storage-system SP Fibre Channel data ports cable B

    Cable B1 (up to 2 per SPE3 SP, optical) number: Length (m or ft):

    Cable B2 (up to 2 per SPE3 SP, optical) number: Length (m or ft):

    Cables between network routers or switches and storage-system SP iSCSI data ports cable B

    Cable B1 (up to 4 per SPE3 SP, Ethernet) number: Length (m or ft):

    Cable B2 (up to 4 per SPE3 SP, Ethernet) number: Length (m or ft):

    Cables between enclosures cable C

    Cable C1 (copper) number (2 per DAE): Length (m or ft): 1.0 m

    Cable C2 (copper) number (2 per DAE): Length (m or ft): 1.0 m

    Configuration Planning Worksheets for CX3-40c Storage Systems 3

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    4/36

    EMC3443

    Switch 1 Switch 2

    Adapter

    Adapter

    Adapter

    Adapter

    Adapter

    Adapter

    B1

    B2

    Cable betweenserver and switch

    Cable betweenswitch and

    storage system

    Cablebetweenenclosures

    LCC LCC

    DAE

    LCC LCC

    DAE

    LCC LCC

    DAE

    LCC LCC

    DAE

    LCC LCC

    DAE

    LCC LCC

    DAE

    SP BSP A

    SPEC1

    C1

    C1

    C1

    C2 C2

    C1

    C1

    C1

    C1

    C1

    C1

    Path 1Path 2

    Path 3 not cabled

    Path 4 not cabled

    A1 AnAmA4

    A2A3

    Figure 1 Cable planning template for a shared storage system with two back-end

    buses (2 front-end cables per SP shown)

    iSCSI Target and Initiator Port Network Information WorksheetEach SP has four iSCSI ports, 0 through 3 (labeled 0 iSCSI through3 iSCSI) for connecting the server NICs or iSCSI HBA ports to thestorage system either directly or through a network. These SP iSCSIdata ports are the iSCSI targets and the ports on the server NICs oriSCSI HBAs are the iSCSI initiators.

    4 Configuration Planning Worksheets for CX3-40c Storage Systems

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    5/36

    Record network information for the iSCSI target ports and iSCSI

    initiator ports in Table 2. Descriptions of the fields follow the worksheet.Your network administrator should provide most of this information.

    Table 2 iSCSI Target and Initiator Port Network Information Worksheet

    iSCSI target port network information

    SP A, 0 iSCSI port IP address: Subnet mask: Gateway:

    SP A, 1 iSCSI port IP address: Subnet mask: Gateway:

    SP A, 2 iSCSI port IP address: Subnet mask: Gateway:

    SP A, 3 iSCSI port IP address: Subnet mask: Gateway:

    SP B, 0 iSCSI port IP address: Subnet mask: Gateway:

    SP B, 1 iSCSI port IP address: Subnet mask: Gateway:

    SP B, 2 iSCSI port IP address: Subnet mask: Gateway:

    SP B, 3 iSCSI port IP address: Subnet mask: Gateway:

    iSCSI initiator port network information

    Server name and

    port identifier Port IP address Subnet mask Gateway

    Configuration Planning Worksheets for CX3-40c Storage Systems 5

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    6/36

    iSCSI target port network information

    IP addressThe static network IP (Internet Protocol) address (for example,128.222.78.10) for communication with the iSCSI port on the SP. Donot use IP addresses 128.221.1.248 through 128.221.1.255, 192.168.1.1,or 192.168.1.2. These ports should be on different subnets from themanagement ports.

    Subnet mask

    The subnet mask for the LAN to which the iSCSI port on the SP isconnected.

    GatewayGateway address if the LAN to which the iSCSI port on the SP isconnected has a gateway.

    iSCSI initiator port network information

    Server name and port identifierThe name of the server with the NIC or iSCSI HBA port and anidentifier for that port.

    IP addressThe static network IP (Internet Protocol) address (for example,128.222.78.10) for communication with the NIC or iSCSI HBA port.This IP address cannot be 128.221.1.250, 128.221.1.251, 192.168.1.1, or192.168.1.2.

    Subnet maskThe subnet mask for the LAN to which the NIC or iSCSI HBA port isconnected.

    GatewayGateway address if the LAN to which the NIC or iSCSI HBA port isconnected has a gateway.

    iSNS Server Worksheet (Windows environment only)

    Enter the public IP address and name of your networks primary iSNSserver and secondary (backup) iSNS server, if you have one, in Table 3.

    Note that the public IP address is not related to the servers iSCSI port

    addresses.

    6 Configuration Planning Worksheets for CX3-40c Storage Systems

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    7/36

    Table 3 iSNS Server Worksheet

    iSNS server IP address Server name

    Primary iSNS server:

    Secondary iSNS server:

    iSCSI CHAP Authentication Worksheets

    If the storage system is on a private LAN, you can elect not to configureCHAP authentication. If the storage system is on a public LAN, westrongly recommend that you set CHAP security. If you do not setCHAP security for the storage system, any host connected to the LANcan read from and write to the storage system.

    !CAUTION

    Whenever you record any security information such as the CHAPusernames and secrets (passwords), it is imperative that you store thedata in a secure location.

    Storage-system CHAP levels

    To set up an initiatorCHAP level, you can add one or more usernames

    and corresponding secrets. Any initiator configured with one of theseusernames/secrets can establish a connection.

    HP-UX and Solaris use the term unidirectional CHAP for initiator CHAP.

    To set up a mutual (target) CHAP level, you can create initiator CHAP

    so that all initiators can use each username/secret or you can alsouse the iSCSI node name (IQN) to create usernames/secrets that arerestricted for use by a single initiator.

    AIX and ESX Server 3.X do not support mutual CHAP. HP-UX and Solaris use

    the term bidirectional CHAP for mutual CHAP.

    Configuration Planning Worksheets for CX3-40c Storage Systems 7

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    8/36

    Initiator CHAP Worksheet

    If you want the storage system to authenticate initiators, fill out Table4 for all initiator accounts. Initiator CHAP must be set up and enabledfor iSCSI security to work. The easiest way to configure initiator CHAPis to create a username and secret for all initiators.

    Table 4 Initiator CHAP Worksheet

    Initiator name:

    Use initiator name as system CHAP username (yes or no):

    Allow any initiator to log in with this username and secret (yes or no):

    CHAP username:

    CHAP secret: Specified in hex (yes or no):

    Initiator name:

    Use initiator name as system CHAP username (yes or no):

    Allow any initiator to log in with this username and secret (yes or no):

    CHAP username:

    CHAP secret: Specified in hex (yes or no):

    Initiator name:

    Use initiator name as system CHAP username (yes or no):

    Allow any initiator to log in with this username and secret (yes or no):

    CHAP username:

    CHAP secret: Specified in hex (yes or no):

    Initiator name:

    Use initiator name as system CHAP username (yes or no):

    Allow any initiator to log in with this username and secret (yes or no):

    CHAP username:

    CHAP secret: Specified in hex (yes or no):

    Initiator nameThe initiator name is a predefined name that usually begins with iqn(for iSCSI Qualified Name). You can determine the name by running

    the SANsurfer utility (shipped with QLogic HBAs) or the Microsoft

    8 Configuration Planning Worksheets for CX3-40c Storage Systems

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    9/36

    iSCSI Software Initiator for Ethernet NICs. The Microsoft iSCSI

    Software Initiator is available on the Microsoft website.Use initiator name as system CHAP usernameIf you want to use the initiator name as the CHAP username, select theUse Initiator Name as System CHAP Username checkbox. If you wantto create a new username, leave the checkbox blank.

    CHAP usernameThe CHAP username is a name that you assign for one user or for all

    users that connect to the storage system iSCSI port. Either you can usethe same name as the initiator name or you can create a new name. Ifyou use the same name as the initiator name, you are guaranteed tohave a unique name. If you create a new username, that name mightnot be unique unless you are on a private network and create a uniquename for the network.

    CHAP secret (password)

    For ASCII, the valid range is 12 to 16 printable characters. Forhexadecimal (hex), the valid range is 24 to 32 hexadecimal characters,displayed in pairs. If you want to specify in hex, mark the checkbox.

    Allow any initiator to log in with this username and secretTo allow any initiator to log in to the storage system, select the Allowany Initiator to Login with this Username and Secret checkbox. If allinitiators are trusted (for example, in a department or organization),

    you might want to select this for convenience. You can always grant orrestrict initiator access to this storage system through the virtual disks.

    Mutual CHAP Worksheet

    Mutual CHAP management provides an optional extra level of securitythat lets initiators verify the identity of the target storage system. If youwant the initiators to authenticate targets, fill out the Mutual CHAPWorksheet in Table 5 for all mutual CHAP accounts.

    Table 5 Mutual CHAP Worksheet

    Target CHAP username:

    Target CHAP secret (password): Specified in hex (yes or no):

    Configuration Planning Worksheets for CX3-40c Storage Systems 9

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    10/36

    !CAUTION

    Whenever you record any security information such as the CHAPusernames and secrets (passwords), it is imperative that you store thedata in a secure location.

    Storage-System Management Ports WorksheetRecord network information for the storage-system management portsin Table 6. Your network administrator should provide most of thisinformation, except for the login information.

    Table 6 Storage-System Management Ports Worksheet

    Storage-system information

    Storage-system serial number:

    Network information

    IP address SP A: SP B:

    Subnet

    mask SP A: SP B:

    Gateway SP A: SP B:

    Login information

    Username: Password:Role: Monitor Manager Administrator

    Security Administrator

    Storage-system information

    Storage-system serial numberThe hardware serial number (TLA S/N) is on a blue vertical label thatis located on the far left of the chassis behind the front bezel (Figure 2).

    To remove the front bezel, unlock it, and then press the latches on its front

    sides and pull the bezel toward you.

    10 Configuration Planning Worksheets for CX3-40c Storage Systems

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    11/36

    EMC3420

    Serial number

    TLAS

    /Nxxxxxxxx

    Figure 2 Location of storage-system serial number (front bezel removed)

    Network information

    IP addressThe static network IP (Internet Protocol) address (for example,128.222.78.10) for communication with a 10/100 management port of astorage processor (SP A or SP B). Do not use IP addresses 128.221.1.248through 128.221.1.255, 192.168.1.1, or 192.168.1.2. Each SP has onemanagement port that must connect to the same subnet as the host usedto initialize the storage system.

    Subnet maskThe subnet mask for the LAN to which the storage system is connectedfor management, for example, 255.255.255.0.

    GatewayGateway address if the LAN to which the storage-system managementport is connected has a gateway.

    Login informationUsernameA username for the management interface. It must start with aletter and may contain 1 to 32 letters and numbers. The name maynot contain punctuation, spaces, or special characters. You can useuppercase and lowercase characters. Usernames are case-sensitive.For example, ABrown is a different username from abrown. Yournetwork administrator may provide the username. If not, then youneed to create one.

    PasswordA password to connect to the management interface. It may contain1 to 32 characters, consisting of uppercase and lowercase lettersand numbers. As with the username, passwords are case-sensitive.For example, Azure23 is a different password than azure23. Thepassword is valid only for the username you specified. Your network

    Configuration Planning Worksheets for CX3-40c Storage Systems 11

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    12/36

    administrator may provide the password. If not, then you need tocreate one.

    User rolesFour basic user roles are available - monitor, manager, administrator,and security administrator. All users, except a security administrator,can monitor the status of a storage system. Users with the manager rolecan also configure a storage system. Administrators can maintain useraccounts, as well as configure a storage system. Security administratorscan only manage security and domain settings.

    CLARalert Worksheet

    Record the network information for the CLARalert monitor stationand the portal system in Table 7.

    Table 7 CLARalert Worksheet

    Monitor station network information

    Host identifier: IP address:

    Portal system network information

    Portal identifier: IP address: Username: Password:

    Monitor station network information

    Host identifierThe optional name or description that identifies the Windows hostthat will be the monitor station.

    IP addressThe network IP (Internet Protocol) address (for example, 128.222.78.10)for communication with the monitor station. This address must be astatic or DHCP reserved IP address. The portal system uses this IP

    address to manage the monitor station.

    Since multiple NICs can exist on this station, you must specify an IP address.

    This IP address cannot be 128.221.1.250, 128.221.1.251, 192.168.1.1, or 192.168.1.2.

    12 Configuration Planning Worksheets for CX3-40c Storage Systems

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    13/36

    Portal system network information

    Portal identifierOptional identifier (such as a hostname) for the storage system that isor will be the portal system.

    IP addressThe network IP address for communicating with the portal system.This IP address is the IP address that you assign to one of the storagesystems SPs when you initialize it.

    UsernameThe username for logging into the portal.

    PasswordThe password for the username for logging into the portal.

    Configuration Planning Worksheets for CX3-40c Storage Systems 13

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    14/36

    Storage allocation planning worksheetsThis section contains the following worksheets:

    Application and LUN Worksheet, page 14

    LUN Details Worksheet, page 15

    LUN and Storage Group Worksheet, page 22

    Application and LUN Worksheet

    Use the Application and LUN Worksheet in Table 8 to list theapplications you will run, and the RAID type and size of the LUN tohold them. For each application that will run, write the applicationname, file system (if any), RAID type, LUN ID (ascending integers,starting with 0), disk space required, and finally the name of the servers

    and operating systems that will use the LUN.

    Table 8 Application and LUN Worksheet

    Application File system, partition,

    or drive

    LUN RAIDtype LUN ID

    (hex)

    Disk space

    required

    (GB)

    Server hostname and

    operating system

    ApplicationEnter the application name or type.

    14 Configuration Planning Worksheets for CX3-40c Storage Systems

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    15/36

    File system, partition, or driveWrite the planned file system, partition, or drive name here.

    With a Windows operating system, the drive letter identifies the LUN.The letter does not help you identify the disk configuration (such asRAID 5). We suggest that later, when you use the operating system tocreate a partition on a LUN, you use the disk administrator softwareto assign a volume label that describes the RAID type. For example,for drive T, assign the volume ID RAID5_T. The volume label willthen identify the drive letter.

    LUN RAID typeThis is the RAID group type you want for this file system, partition, ordrive. You can create one or more LUNs on the RAID group.

    LUN IDThe LUN ID is a hexadecimal number assigned when you bind thedisks into a LUN. By default, the ID of the first LUN bound is 0, the

    second 1, and so on. Each LUN ID must be unique within the storagesystem, regardless of its storage group or RAID group.

    The maximum number of LUNs supported on one host bus adapterdepends on the operating system.

    Disk space required (GB)Consider the largest amount of disk space this application will need,and then add a factor for growth.

    If sometime in the future, you find that you need more space for this

    application, you can expand the capacity of the LUN by adding other LUNs to

    it. For information on expanding LUNs, refer to the Navisphere Manager online

    help, which is available on the Powerlink website (http://Powerlink.EMC.com).

    Server hostname and operating system

    Enter the server hostname (or, if you do not know the name, a shortdescription that identifies the server) and the operating system name,if you know it.

    LUN Details Worksheet

    Use the LUN Details Worksheet in Table 9 to plan the individual LUNs.Complete as many blank worksheets as needed for all LUNs in storage

    systems. For unshared storage, skip the storage group entries.

    Configuration Planning Worksheets for CX3-40c Storage Systems 15

    http://powerlink.emc.com/http://powerlink.emc.com/http://powerlink.emc.com/http://powerlink.emc.com/
  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    16/36

    Table 9 LUN Details Worksheet

    Storage-system information

    Storage-system number or name:

    Storage-system installation type: Unshared direct Shared-or-clustered direct Shared switched

    SP A information

    IP address or hostname: Port ALPA ID: Memory (MB):

    SP B information

    IP address or hostname: Port ALPA ID: Memory (MB):

    Cache information

    Read cache size: Write cache size: Cache page size:

    LUN information

    LUN ID:SP owner: SP A SP B

    SP back-end bus (0 or 1):

    RAID group ID: RAID group size (GB): LUN size (GB): Disk IDs:

    RAID type:RAID 6 RAID 5 RAID 3 RAID 1 mirrored pair RAID 0 RAID 1/0 Individual disk

    Hot spare

    Read and write Write only Read only NoneCaching:

    Read cache size: Write cache size: Cache page size:

    Servers that can access this LUNs storage group:

    Operating system information

    Device name: File system, partition, or drive:

    16 Configuration Planning Worksheets for CX3-40c Storage Systems

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    17/36

    LUN information

    LUN ID: SP owner: SP A SP B SP back-end bus (0 or 1):

    RAID group ID: RAID group size (GB): LUN size (GB): Disk IDs:

    RAID type:RAID 6 RAID 5 RAID 3 RAID 1 mirrored pair RAID 0 RAID 1/0 Individual disk

    Hot spare

    Read and write Write only Read only NoneCaching:

    Read cache size: Write cache size: Cache page size:

    Servers that can access this LUNs storage group:

    Operating system information

    Device name: File system, partition, or drive:

    LUN information

    LUN ID:SP owner: SP A SP B

    SP bus (0 or 1)

    RAID group ID: RAID group size (GB): LUN size (GB): Disk IDs:

    RAID type:RAID 6 RAID 5 RAID 3 RAID 1 mirrored pair RAID 0 RAID 1/0 Individual disk

    Hot spare

    Read and write Write only Read only NoneCaching:

    Read cache size: Write cache size: Cache page size:

    Servers that can access this LUNs storage group:

    Storage-system information

    Storage-system name or number

    Enter the number or name that identifies the storage system.Storage-system installation typeSpecify unshared direct, shared-or-clustered direct, or shared switched.

    MemoryEnter the amount of memory on the SP.

    Configuration Planning Worksheets for CX3-40c Storage Systems 17

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    18/36

    SP A and SP B information

    IP addressEnter the IP address or hostname for the SP. The IP address is requiredfor communication with the SP. You do not need to complete it now,

    but you will need it when the storage system is installed so that youcan set up communication with the SP.

    Port ALPA IDFor shared storage (switches), the SP ALPA ID is ignored for all except

    HP-UX servers. For unshared storage, each SP connected to a servermust have a unique SP Port ALPA ID; for example, for two storagesystems, use IDs 0, 1, 2, and 3. The SP Port ALPA ID, like the IPaddress, is generally set at installation.

    Cache information

    You can use SP memory for read/write caching. You can use differentcache settings for different times of day. For example, for user I/O

    during the day, use more write cache; for sequential batch jobs at night,use more read cache. Generally, write caching improves performancefar more than read caching. Read caching is nonetheless crucial forgood sequential read performance, as seen in backups and table scans.The ability to specify caching on a LUN basis provides additionalflexibility, since you can use caching for only the units that will benefitfrom it. Read and write caching is recommended for any type ofRAID group, particularly RAID 6 or RAID 5. You enable caching forspecific LUNs allowing you to tailor your cache resources accordingto priority.

    The maximum cache size per SP is 3016 MB, and the maximum writecache size is 2500 MB.

    Read cache sizeIf you want a read cache, we recommend for a storage system with themaximum cache memory that the read cache should be about 516 MB,which is the amount available per SP after assigning the maximumallowed amount to the write cache.

    Write cache sizeGenerally, for a storage system with the maximum cache memory, werecommend that the write cache should be the maximum allowed size,which is 2500 MB per SP.

    18 Configuration Planning Worksheets for CX3-40c Storage Systems

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    19/36

    Cache page sizeCache page size applies to both read and write caches. It can be 2, 4, 8,or 16 KB. As a general guideline, we suggest 8 KB. The ideal cache pagesize depends on the operating system and application.

    LUN information

    LUN IDThe LUN ID is a hexadecimal number assigned when you bind thedisks into a LUN. By default, the ID of the first LUN bound is 0, the

    second 1, and so on. Each LUN ID must be unique within the storagesystem, regardless of its storage group or RAID group. The maximumnumber of LUNs supported on one host bus adapter depends on theoperating system.

    SP ownerThe SP owner is the SP that will own the LUN: SP A or SP B. You canlet the management program automatically select the SP to balance the

    workload between SPs; to do so, leave this entry blank.SP back-end buses

    Each SP supports two physical back-end buses that are paired with thecounterpart SP to create two redundant buses (buses 0 and 1). If youhave both 2 Gb/s and 4 Gb/s disks, you should put the 2 Gb/s diskson one bus and the 4 Gb/s disks on the other bus. Ideally, you shouldplace the same amount of load on each bus. This may mean placing

    two or three heavily used LUNs on one bus and six or seven lightlyused LUNs on the other bus.

    The bus designation appears in the disk ID (form b-e-d, where b is theback-end bus number, e is the enclosure number, and d is the diskposition in the enclosure). For example, 0-1-3 indicates the fourth diskon bus 0, in enclosure 1 (numbering 0, 1, 2, 3... from the left) in thestorage system.

    RAID group IDThis ID is a hexadecimal number assigned when you create the RAIDgroup. By default, the number of the first RAID group in a storagesystem is 0, the second 1, and so on, up to the number of disk drives inthe system.

    RAID group sizeEnter the user-available capacity in gigabytes (GB) of the whole RAID

    group. You can determine the capacity as follows:

    Configuration Planning Worksheets for CX3-40c Storage Systems 19

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    20/36

    RAID group Disk capacity (GB)

    RAID 6 group disk-size x (number-of-disks - 2)

    RAID 5 or RAID 3 group disk-size x (number-of-disks - 1)

    RAID 1/0 or RAID 1 group (disk-size x number-of-disks) / 2

    RAID 0 group disk-size x number-of-disks

    Individual unit disk-size

    Usable disk space differs from the drive size reported by themanufacturer. A drive manufacturers definition of a gigabyte is1,000,000,000 bytes and the storage systems "true" definition is 1024x 1024 x 1024, or 1,073,741,824 bytes. Typical conversions are shown

    below.

    Available GB

    Listed Capacity Disk 0-4 (vault disk) Other

    73 GB 33.64 GB 66.61 GB

    146 GB 100.68 GB 133.65 GB

    300 GB 235.40 268.37

    500 GB N/A 458.56

    750 GB N/A 687.86

    Notes: 500-GB and 750-GB are ATA disks and they cannot be used as vault disks (disk 0-4)

    For example:

    A 6-disk RAID 6 group or 5-disk RAID 5 or RAID 3 group of 300-GBdisks holds either 941.62 GB if all disks are vault disks (disks 0-4) or1073.48 GB if it does not include vault disks.

    A 4-disk RAID 1/0 group of 300-GB disks holds either 470.81 GBif all disks are vault disks or 536.74 GB if it does not include vault

    disks.

    A RAID 1 mirrored pair of 300-GB disks holds either 235.40 GBif the pair includes vault disks or 268.37 GB if it does not includevault disks.

    An individual disk (RAID 1) of a 300-GB disk holds either 235.40GB if it is a vault disk or 268.37 GB if it is not a vault disk.

    20 Configuration Planning Worksheets for CX3-40c Storage Systems

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    21/36

    LUN sizeEnter the user-available capacity in gigabytes (GB) of the LUN. You canmake this the same size or smaller than the RAID group. You mightmake a LUN smaller than the RAID group size if you want a RAID5 group with a large capacity and you want to place many smallercapacity LUNs on it; for example, to specify a LUN for each user.

    Multiple LUNs per disk group share the same total performance capability

    of the disk drives, so plan carefully.

    If you want multiple LUNs per RAID group, then use a RAIDgroup/LUN series of entries for each LUN.

    Disk IDsEnter the IDs of all disks that will make up the LUN or hot spare. Theseare the same disk IDs you specified on the previous worksheet. Forexample, for a RAID 5 group in a DAE on bus 0 (disks 10 through 14),

    enter 0010, 0011 , 0012, 0013 , and 0014.

    RAID typeCopy the RAID type from the previous worksheet; for example, RAID5 or hot spare. For a hot spare (strictly speaking not a LUN at all), skipthe rest of this LUN entry and continue to the next LUN entry (if any).

    CachingIf you want to use caching, you can specify the type of caching youwant read and write, write, read, or none for this LUN.

    Servers that can access this LUNs storage groupFor shared switched storage or shared-or-clustered direct storage, enterthe name of each server (copied from the LUN and storage groupworksheet). For unshared direct storage, this entry does not apply.

    Operating system information

    Device nameEnter the operating system device name, if this is important and if youknow it. Depending on your operating system, you may not be ableto complete this field now.

    File system, partition, or driveWrite the name of the file system, partition, or drive letter you willcreate on this LUN. This is the same name you wrote on the application

    worksheet.

    Configuration Planning Worksheets for CX3-40c Storage Systems 21

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    22/36

    On the following line, write any pertinent notes; for example, the filesystem mount-point or graft-point directory pathname (from the rootdirectory). If any of this storage systems LUNs will be shared withanother server, and the other server is the primary owner of this LUN,write secondary. (As mentioned earlier, if the storage system will beused by two servers, we suggest you complete one of these worksheetsfor each server.)

    LUN and Storage Group Worksheet

    Use the LUN and Storage Group Worksheet in Table 10 to select thedisks that will make up the LUNs and storage groups in each storagesystem. Unshared storage systems do not use storage groups. Forunshared storage, skip the storage group entry.

    Table 10 LUN and Storage Group Worksheet

    Storage-system number or name:

    Storage group ID or name: Server hostname:Dedicated

    Shared

    LUN ID or name: RAID type: Capacity (GB): Disk IDs:

    LUN ID or name: RAID type: Capacity (GB): Disk IDs:

    LUN ID or name: RAID type: Capacity (GB): Disk IDs:

    LUN ID or name: RAID type: Capacity (GB): Disk IDs:

    Storage-system number or name:

    Storage group ID or name: Server hostname:Dedicated

    Shared

    LUN ID or name: RAID type: Capacity (GB): Disk IDs:

    LUN ID or name: RAID type: Capacity (GB): Disk IDs:

    LUN ID or name: RAID type: Capacity (GB): Disk IDs:

    LUN ID or name: RAID type: Capacity (GB): Disk IDs:

    Storage-system number or name:

    22 Configuration Planning Worksheets for CX3-40c Storage Systems

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    23/36

    Storage group ID or name: Server hostname:Dedicated

    Shared

    LUN ID or name: RAID type: Capacity (GB): Disk IDs:

    LUN ID or name: RAID type: Capacity (GB): Disk IDs:

    LUN ID or name: RAID type: Capacity (GB): Disk IDs:

    LUN ID or name: RAID type: Capacity (GB): Disk IDs:

    Complete as many of the storage system sections as needed for allthe storage groups in the SAN (or as needed for all the LUNs withunshared storage). Copy the (blank) worksheet as needed.

    For shared storage, if a storage group will be dedicated (not accessibleby another server in a cluster), mark the Dedicated box at the end of itsline; if the storage group will be accessible to one or more other serversin a cluster, write the hostnames of all servers and mark the Shared box.

    For unshared storage, ignore the Dedicated/Shared boxes.

    Configuration Planning Worksheets for CX3-40c Storage Systems 23

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    24/36

    Data replication and mobility planning worksheetsThis section contains the following worksheets:

    SnapView worksheets, page 24

    MirrorView/A worksheets, page 27

    MirrorView/S worksheets, page 30

    SAN Copy worksheets, page 32

    SnapView worksheets

    The worksheets in Table 11, Table 12, and Table 13 will help you planyour clones and snapshots. The first worksheet is for clone planning;the second is for snapshot planning; the third is for reserved LUN poolplanning for snapshots.

    Clone Worksheet

    The Clone Worksheet in Table 11 will help you plan for clones. Notethat the size of the clone private LUNs (one for each SP) is fixed and itis quite modest, so the worksheet does not include it.

    Note: With SnapView version 6.24 or later, a clones source LUN can be a

    remote mirror LUN (a LUN participating as either a primary or secondary

    image).

    24 Configuration Planning Worksheets for CX3-40c Storage Systems

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    25/36

    Table 11 Clone Worksheet

    LUN

    Production

    hostname Source LUN ID Storage group ID Size (GB)

    Application, file system, or database

    name

    Configuration Planning Worksheets for CX3-40c Storage Systems 25

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    26/36

    Snapshot Worksheet

    For each SnapView session, you must complete a Snapshot Worksheetin Table 12. Note that you must assign the LUN and snapshotto different storage groups. One storage group must include theproduction host and source LUN; another storage group must includethe second host and the snapshot.

    Table 12 Snapshot Worksheet

    LUN

    Reserved LUN

    pool

    Production

    hostname

    Source

    LUN ID

    Storage

    group ID

    Size

    (MB)

    Application,

    file system, or

    database name

    LUN ID or

    name

    Size

    (MB)

    SP (both

    LUN and

    cache)

    Time of

    day to

    copy

    Session

    name

    Reserved LUN Pool Worksheet

    Since snapshots use the reserved LUN pool, you need the followinginformation for system setup so you can bind LUNs for the reservedLUN pool. The number of reserved LUNs should always be twice thenumber of source LUNs. Note that MirrorView/A and incrementalSAN Copy also use the reserved LUN pool. One application can use areserved LUN as long as another application is not using it.

    26 Configuration Planning Worksheets for CX3-40c Storage Systems

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    27/36

    The Reserved LUN Pool Worksheet in Table 13 is also provided in theMirrorView/A and incremental SAN Copy sections.

    Table 13 Reserved LUN Pool Worksheet

    SP (A or B)

    Only for

    Navisphere

    Manager6.22 or

    earlier Source LUN size

    RAID type for

    reserved LUN pool

    RAID group ID of

    parent RAID group

    Reserved LUN size

    (GB)

    Reserved LUN IDor name (complete

    after binding)

    Notes: For Navisphere 6.24 or later you no longer assign LUNs in the reserved LUN pool to an SP, so the first column of the worksheet

    SP (A or B) is not needed. We recommend that the reserved LUN size is 20% of the source LUN size.

    MirrorView/A worksheets

    The worksheets in Table 14 and Table 15 will help you plan your remoteasynchronous mirrors. The first is for mirror planning, and the secondis for reserved LUN pool planning.

    You must assign each primary image LUN to a storage group (as withany normal LUN), but you must not assign a secondary image LUN toa storage group. If primary image LUNs are in a consistency group, allsecondary image LUNs must be on the same remote storage system.

    Configuration Planning Worksheets for CX3-40c Storage Systems 27

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    28/36

    The worksheet in Table 16 will help you plan iSCSI connection setsfor iSCSI replication.

    Table 14 Remote Asynchronous Mirrors Worksheet

    Production

    hostname

    Primary

    LUN ID,

    size, and

    file system

    name

    Storage

    group

    number

    or name

    Use write

    intent log

    (Y/N)

    SP

    (A/B)

    Remote

    mirror

    name

    Secondary

    hostname

    Secondary

    image LUN

    ID

    Group name (if

    applicable)

    Since MirrorView/A uses the reserved LUN pool, you need thefollowing information for system setup so you can bind LUNs for thereserved LUN pool. The number of reserved LUNs should always betwice the number of source LUNs. A MirrorView/A primary imageLUN is a source LUN. Note that SnapView and incremental SAN Copy

    also use the reserved LUN pool. One application can use a reservedLUN as long as another application is not using it.

    The Reserved LUN Pool Worksheet in Table 15 is also provided in theSnapView and incremental SAN Copy sections.

    28 Configuration Planning Worksheets for CX3-40c Storage Systems

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    29/36

    Table 15 Reserved LUN Pool Worksheet

    SP (A or B)Only for

    Navisphere

    Manager

    6.22 or

    earlier Source LUN size

    RAID type for

    reserved LUN pool

    RAID group ID of

    parent RAID group

    Reserved LUN size

    (GB)

    Reserved LUN ID

    or name (complete

    after binding)

    Notes: For Navisphere 6.24 or later you no longer assign LUNs in the reserved LUN pool to an SP, so the first column of the worksheet

    SP (A or B) is not needed. We recommend that the reserved LUN size is 20% of the source LUN size.

    If you are using iSCSI MirrorView/A replication, fill out the informationin Table 16 for the iSCSI connection sets that you want to configure.

    Configuration Planning Worksheets for CX3-40c Storage Systems 29

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    30/36

    Table 16 iSCSI Connection Sets Worksheet

    Connection pathUniqueconnection set

    name

    Optional

    username

    Optionalpassword

    (secret)

    Credential usage(specific, shared,

    none)

    iSCSI

    initiator port

    Target system IP

    address

    Target iSCSI

    port

    MirrorView/S worksheets

    The worksheets in Table 17 and Table 18 help you plan your remotemirrors. The first worksheet is for remote mirror planning, and thesecond is for the optional write intent log planning. You must assigneach primary image LUN to a storage group (as with any normal LUN),

    but you must not assign a secondary image LUN to a storage group.

    The worksheet in Table 19 will help you plan iSCSI connection setsfor iSCSI replication.

    30 Configuration Planning Worksheets for CX3-40c Storage Systems

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    31/36

    Table 17 Remote Synchronous Mirrors Worksheet

    Production

    hostname

    PrimaryLUN ID,

    size, and

    file system

    name

    Storage

    group

    number or

    name

    Use write

    intent log

    (Y/N)

    SP

    (A/B)

    Remote

    mirror name

    Secondary

    hostname

    Secondary

    image LUN

    ID

    Group

    name (if

    applicable)

    Notes: By default, newly created remote mirrors do not use the write intent log, so you do not need to allocate space for the write intent

    log. However, before you use it, you must allocate space for it. If you want to use the write intent log, enter Y, and, after completing the

    worksheet, fill out the Write Intent Log Worksheet on the next page.

    If you decide to use the write intent log feature for even one remotemirror, then you must bind two LUNs of at least 128 MB for the writeintent log.

    Table 18 Optional Write Intent Log Worksheet

    LUN LUN name or ID LUN size (128 MB minimum)

    First LUN

    Second LUN

    Configuration Planning Worksheets for CX3-40c Storage Systems 31

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    32/36

    If you are using iSCSI MirrorView/S replication, fill out the informationin Table 19 for the iSCSI connection sets that you want to configure.

    Table 19 iSCSI Connection Sets Worksheet

    Connection pathUnique

    connection set

    name

    Optional

    username

    Optional

    password

    (secret)

    Credential usage

    (specific, shared,

    none)

    iSCSI

    initiator port

    Target system IP

    address

    Target iSCSI

    port

    SAN Copy worksheets

    The worksheets in Table 20, Table 21, and Table 22 will help you planSAN Copy sessions. The first worksheet is for sessions between storagesystems; the second is for sessions within the same storage system; andthe third is for reserved LUN pool planning.

    The worksheet in Table 23 will help you plan iSCSI connection setsfor iSCSI replication.

    One of the storage systems in the session must be a SAN Copy storage system,

    that is, it must have SAN Copy installed on it.

    32 Configuration Planning Worksheets for CX3-40c Storage Systems

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    33/36

    Table 20 SAN Copy Worksheet for a Session Between Storage Systems

    Session nameSAN Copy storage-system name

    Source storage-system name

    Source logical unit name

    Destination storage-system name

    Destination logical unit names

    For a SAN Copy session between logical units in the same storagesystem, the same SP must own the logical units.

    Table 21 SAN Copy Worksheet for a Session Within a Storage System

    Session name

    Source storage-system name

    Source logical unit name

    Destination logical unit names

    Incremental SAN Copy uses the reserved LUN pool, so if you wantto use this type of SAN Copy, you need the following informationfor system setup so you can bind LUNs for the reserved LUN pool.The number of reserved LUNs should always be twice the number of

    source LUNs. Note that MirrorView/A and SnapView also use thereserved LUN pool. One application can use a reserved LUN as long asanother application is not using it.

    The Reserved LUN Pool Worksheet in Table 22 is also in the SnapViewand MirrorView/A sections.

    Configuration Planning Worksheets for CX3-40c Storage Systems 33

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    34/36

    Table 22 Reserved LUN Pool Worksheet

    SP (A or B)Only for

    Navisphere

    Manager

    6.22 or

    earlier Source LUN size

    RAID type for

    reserved LUN pool

    RAID group ID of

    parent RAID group

    Reserved LUN size

    (GB)

    Reserved LUN ID

    or name (complete

    after binding)

    Notes: For Navisphere 6.24 or later you no longer assign LUNs in the reserved LUN pool to an SP, so the first column of the worksheet

    SP (A or B) is not needed. We recommend that the reserved LUN size is 20% of the source LUN size.

    If you are using iSCSI MirrorView/A replication, fill out the informationin Table 23 for the iSCSI connection sets that you want to configure.

    34 Configuration Planning Worksheets for CX3-40c Storage Systems

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    35/36

    Table 23 iSCSI Connection Sets Worksheet

    Connection pathUniqueconnection set

    name

    Optional

    username

    Optionalpassword

    (secret)

    Credential usage(specific, shared,

    none)

    iSCSI

    initiator port

    Target system IP

    address

    Target iSCSi

    port

    Configuration Planning Worksheets for CX3-40c Storage Systems 35

  • 8/22/2019 Cx3 40c Iscsi Fc Plan Worksheets

    36/36

    Copyright 20062007 EMC Corporation. All Rights Reserved.

    EMC believes the information in this publication is accurate as of its publication date. Theinformation is subject to change without notice.

    THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS." EMC CORPORATIONMAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TOTHE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED

    WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

    Use, copying, and distribution of any EMC software described in this publication requires anapplicable software license.

    For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks onEMC.com.

    All other trademarks used herein are the property of their respective owners.

    36 Configuration Planning Worksheets for CX3-40c Storage Systems