Cutler-HammerJanuary 2001Vol. 2, Ref. No. 10025]
NEMA Contactors & StartersStarters — 3-Phase, Full VoltageFreedom Line — Non-reversing and Reversing
Product SelectionWhen Ordering Supplym Catalog Number• Heater pack number (see selection
table, Pages 33-36 - 33-37 or full loadcurrent.
SizeONon-reversing Starter
Size 7Reversing Starter
Size 3 VerticalReversing Starter
Table 33-10. Type AN16/AN56 NEMA — Manual or Automatic Reset Overload Relay — Non-reversing and ReversingNEMASize
00012345678®
ContinuousAmpereRating
918274590
135270540810
1215
Service-LimitCurrent Rating ?(Amperes)
11213252
104156311621932
1400
Maximum UL Horsepower 11 -Phase115V
1/3123—————
—
230V1237-1/2—————
—
3-Phase208V
1-1/237-1/2
10254075
150200400
240V1-1/237-1/2
153050
100200300450
480V25
102550
100200400600900
600V25
102550
100200400600900
3-PoleNon-reversingAIM16ANO CAN16BNO_CAN16DNO BAN16GNO B
AN16KNO_AN16NNOAIM16SNO BAN16TNO CAN16UNO_BAN16VNO B
PriceU.S. $
182.228.262.476.775.
1,760.4,300.9,930.
14,160.22,010.
3-PoleReversingAN56ANOJ:AN56BNO_CAN56DNO_BAN56GNO_BAN56KNO_AN56NNOAN56SNO_BAN56TNO_CAN56UNO BAN56VNO B
VerticalReversing
—AN56BNVO_AN56DNVO_AN56GNVO_AN56KNVO_AN56NNVO_———
—
PriceU.S. $
435.515.585.
1,110.1,835.4,475.8,590.
19,990.28,995.42,614.
Note: Starter Catalog Numbers do not include heater packs. Select one carton of three heater packs. Heater pack selection, Pages 33-36 - 33-37.® Maximum horsepower rating of starters for 380V 50 Hz applications:
NEMA Size 00
Horsepower 1-1/2 10 25 50 75 150 300 600 900
® The service-limit current ratings represent the maximum rms current, in amperes, which the controller shall be permitted to carry for protracted periodsin normal service. At service-limit current ratings, temperature rises shall be permitted to exceed those obtained by testing the controller at itscontinuous current rating. The current rating of overload relays or trip current of other motor protective devices used shall not exceed the service-limitcurrent rating of the controller.
® Common control. For separate 120V control, insert letter D in 7th position of listed Catalog Number. EXAMPLE: AN56VNDOCB.
NEMA Size 0Cat. No. AN56BNOAC
Magnet Coils —AC or DCStarter coils listed in this section alsohave a 50 Hz rating as shown in theadjacent table. Select required starterby Catalog Number and replace themagnet coil alpha designation in theCatalog Number (_) with the properCode Suffix from the adjacent table.
For Sizes 00-2 and 5-8, the magnetcoil alpha designation will be the nextto last digit of the listed Catalog Num-ber. EXAMPLE: For a 380V, 50 Hz coil,change AN16BNO_C to AN16BNOLC.For all other sizes, the magnet coilalpha designation will be the last digitof the listed Catalog Number.
For DC Magnet Coils, see Accessories,Pages 33-21 - 33-22.
Table 33-11. AC Suffix CodeCoil Volts and Hertz Code Suffix
120/60 or 110/50240/60 or 220/50480/60 or 440/50600/60 or 550/50208/60277/60208-240/60 4
240/50380-415/50550/5024/60, 24/50 '•!>24/5032/5048/6048/50
ABCDEHJK
LNTUVwY
NEMA Sizes 00 and 0 only.NEMA Sizes 00 and 0 only. Sizes 1 - 8 are24/60 only.
Technical D a t a . . . . . . . . . . . . . Pages 33-12-33-14Dimensions . . . . . . . . . . . . . . . Pages 33-28 - 33-30Special Modifications . . . . . . Page 33-23A c c e s s o r i e s . . . . . . . . . . . . . . . Pages 33-15 - 33-23Heater P a c k s . . . . . . . . . . . . . . Pages 33-36 - 33-37Discount Symbo l . . . . . . . . . . . 1CD1
CAT.201.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog F:T-
Cutler-HammerJanuary 2001Vol. 2, Ref. No. 10023]
NEMA Contactors & StartersStarters — 3-Phase, Full VoltageFreedom Line — Non-reversing and Reversing
PageContentsDescription
Product Family OverviewProduct Description . . . . . . 33-2Application Description . . . 33-2Features . . . . . . . . . . . . . . . 33-2Standards and
Certifications . . . . . . . . . . 33-3Starters — 3-Phase Non-reversing
and Reversing, Full VoltageProduct Description . . . . . . 33-7Features . . . . . . . . . . . . . . . 33-7Technical Data . . . . . . . . . . 33-8Wiring Diagrams . . . . . . . . 33-8Product Selection. . . . . . . . 33-9
Starters — 3-Phase MultispeedProduct Select ion.. . . . . . . 33-10
Starters — Single-PhaseNon-reversing, Full Voltage
Product Description...... 33-11Wiring Diagrams . . . . . . . . 33-11Product Selection. . . . . . . . 33-11
Technical D a t a . . . . . . . . . . . . . 33-12Accessories . . . . . . . . . . . . . . . 33-15
Auxiliary Contacts . . . . . . . 33-19DC Magnet Coils . . . . . . . . 33-21Mounting P la tes . . . . . . . . . 33-22
Special Modifications....... 33-23Renewal Parts . . . . . . . . . . . . 33-24Dimensions . . . . . . . . . . . . . . . 33-26
NEMA Size 1 — Cat No. AN16BNOAB
Product DescriptionNon-reversingThree-phase, full voltage magneticstarters are most commonly used toswitch AC motor loads. Starters con-sist of a magnetically actuated switch(contactor) and an overload relayassembled together.
NEMA Size 1 — Cat. No. AN56DNOAB
ReversingThree-phase, full voltage magneticstarters are used primarily for revers-ing of 3-phase squirrel cage motors.They consist of two contactors and asingle overload relay assembledtogether. The contactors are mechani-cally and electrically interlocked toprevent line shorts and energizationof both contactors simultaneously.
Features• Bimetallic Ambient Compensated
Overload relays — available in threebasic sizes covering applications upto 900 hp — reducing number ofdifferent contactor/overload relaycombinations that have to bestocked.These overload relays feature:a Selectable Manual or Automatic
Reset operation.a Interchangeable heater packs
adjustable ±24% to match motorFLA and calibrated for 1.0 and1.15 service factors. Heater packsfor smaller overload relay willmount in larger overload relay —useful in derating applicationssuch as jogging.
a Load lugs built into relay base.a Single-phase protection, Class 20
or Class 10 trip time.a Overload trip indication.a Electrically isolated NO-NC con-
tacts (pull RESET button to test).
• Long life twin break, silver cadmiumoxide contacts — provide excellentconductivity and superior resistanceto welding and arc erosion. Gener-ously sized for low resistance andcool operation.
• Designed to 3,000,000 electricaloperations at maximum hp ratingsup through 25 hp at 600V.
• Steel mounting plate standard on allopen type starters.
• Wired for separate or commoncontrol.
Non-reversing• Holding circuit contact(s) supplied
as standard:U Sizes 00-3 have a NO auxiliary
contact block mounted on right-hand side (on Size 00, contactoccupies 4th power pole position— no increase in width).
a Sizes 4-5 have a NO contactblock mounted on left side.
Q Sizes 6-7 have a 2NO/2NCcontact block on top left.
a Size 8 has a NO/NC contact blockon top left back and a NO on topright back.
Reversing• Each contactor (Size 00 - 8)
supplied with one NO-NC sidemounted contact block as standard.NC contacts are wired as electricalinterlocks.
CAT.201.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog F.T'N
Cutler-HammerJanuary 2001Vol. 2, Ref. No. 10037]
NEMA Contactors & StartersAccessoriesFreedom Line
33-21
DC Magnet CoilsWhen Ordering SpecifyConversion Kit for Field Assembly
• Catalog Number
Factory Installed DC Coil
• For factory installed DC magnetcoil on AC contactors or non-combination starters (open typeonly), substitute the Code Suffixfrom table below for the magnet coilidentifier in the device CatalogNumber.
EXAMPLE: For Size 0 AC contactorwith a 24V DC coil, changeAN16BNOAC to AN16BNOT1C.
Application• Connect for separate control• Not for use with cover control
switch operators• Use twin break, heavy-duty pilot
devices.• Designed for +10%, -20% rated volt-
age, continuous duty operation.
Non-reversing Kit Consists of:• 1 Encapsulated DC magnet coil• 1 NCI or NO/NCI side mounted
auxiliary contactNote: These kits are supplied with aNO/NCI side mounted auxiliary contactin place of the NCI contact.
• 2 Blue colored connection wires• 1 Instruction publication
OperationSee next page for operation details.
Table 33-46. Product SelectionContactor orStarter Size
NEMA IEC
Conversion DataVolts Magnet Coil
CoilNumber
AmpsP.U./Seal
WattsP.U./Seal
NCIInterlock
Complete Conversion Kit
CatalogNumber
PriceU.S.S
Ship Wt.Lbs. (kg)
FactoryInstalled
CodeSuffix
AdderU.S.S
Non-reversing — Kit includes NCI Side Mounted Auxiliary contact00 and 0CN35-A, B, DD15 Relays
0")00 and 0CN35 - A, B, DD15 Relays1 and 2CN35 - G
3CN35-K
4 and 5CN35-N.S
A-F
A-F
G-K
L-N
P-S
122448
120
122448
120
122448
120
122448
120
2448
120240
9-2988-119-2988-129-2988-139-2988-149-2988-119-2988-129-2988-139-2988-149-2990-19-2990-29-2990-39-2990-49-3002-19-3002-29-3002-39-3002-49-2026-49-2026-39-2026-29-2026-1
6.4/.2S3.2/.141.6/.07.64/.028
6.4/.2S3.2/.141.6/.07.64/.028
15.4/.427.7/.213.9/.111.5/.041
24/.4012/.206.1/.0972.5/.038
18/.229/.113.3/.051.7/.02
76.8/3.3676.8/3.3676.8/3.3676.8/3.3676.8/3.3676.8/3.3676.8/3.3676.8/3.36
185/4.98185/4.96185/5.04185/4.87293/4.84288/4.75295/4.67298/4.57400/5.3400/5.2450/5.4440/4.9
C320KGD1C320KGD1C320KGD1C320KGD1C320KGD2 'C320KGD2 'C320KGD2 'C320KGD2 • '•C320KGD5C320KGD5C320KGD5C320KGD5C320KGD3C320KGD3C320KGD3C320KGD3C320KGD3C320KGD3C320KGD3C320KGD3
C335KD3R1C335KD3T1C335KD3W1C335KD3A1C335KD3R4C335KD3T4C335KD3W4C335KD3A4C335KD4R4C335KD4T4C335KD4W4C335KD4A4C335KD5R1C335KD5T1C335KD5W1C335KD5A1C335KA3T1C335KA3W1C335KA3A1C335KA3B1
30.5030.5030.5030.5050.5050.5050.5050.5050.5050.5050.5050.50
75.5075.5075.5075.50
258.00258.00258.00258.00
1.01.5)
1.0 (.5)
1.0 (.5)
2.0 (.9)
2.5(1.1)
R1T1W1A1
R4T4W4A4
R4T4W4A4
R1T1W1A1
T1BW1BA1BB1B
34.0034.0034.0034.0054.0054.0054.0054.0058.0058.0058.0058.0092.0092.0092.0092.00
325.00325.00325.00325.00
Reversing00 and 0CN35-A, B, DD15 Relays
1 and 2CN35-G
A - F
G-K
122448
120
122448
120
(2) 9-2988-1(2) 9-2988-2(2) 9-2988-3(2) 9-2988-4(2] 9-2990-1|2) 9-2990-2(2) 9-2990-3(2) 9-2990-4
6.4A283.2/.141.6/.07.64/.028
15.4/.427.7/.213.9/.111.5/.041
76.8/3.3676.8/3.3676.8/3.3676.8/3.36
185/4.98185/4.96185/5.04185/4.87
(2) C320KGD1(2) C320KGD1(2) C320KGD1(2) C320KGD1
(2) C320KGD3(2) C320KGD3(2) C320KGD3(2) C320KGD3
C335RD3R1 ®C335RD3T1 ®C335RD3W1 2
C335RD3A1 ?.4!
115.00115.00115.00115.00
1.01.5) R1 >T1 *W1 3
A1 A
R1®T1®W1 ®A1CJ)
125.00125.00125.00125.00220.00220.00220.00220.00
& These kits are supplied with a NO/NCI side mounted auxiliary contact in place of the NCI contact.® Kit does not include mechanical interlock or crossover wiring. Two NO/NCI top mounted auxiliary contacts are supplied for electrical interlocking.& Factory installed DC coils on NEMA contactors and starters include a NO/NC top mounted auxiliary contact on each contactor for electrical interlocking.
On IEC contactors and starters, a NC top mounted auxiliary contact is supplied on each contactor for electrical interlocking.@ Available factory assembled only.
Discount Symbo l . . . . . . . . . . . . . . . . . . . . . . . 1CD1C
CAT.201.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog E:T-
33-22 NEMA Contactors & StartersAccessoriesFreedom Line
Cutler-HammerJanuary 2001
Vol. 2, Ref. No. [00381
OperationThese DC coil kits have separate pick-up and seal windings. A special (sidemounted) early-break NCI auxiliarycontact is used to either disconnect thepick-up winding or insert the sealwinding in series with the pick-upwinding, depending on the frame sizeof the contactor. DC coil kits come intwo styles, a suffix 1 and a suffix 4. The1 suffix contains only the special (sidemounted) early break NCI auxiliarycontact. The 4 suffix contains a NOcontact in the same package as thespecial (side mounted) early-break NCIauxiliary contact.
Note: For NEMA Sizes 00 and 0 and IECSizes A - F, contactors may utilize either suf-fix 1 or 4 DC coil kits; starters may utilize suf-fix 4 DC coil kits only. For NEMA Sizes 1 and2 and IEC Sizes G - K, both contactors andstarters may utilize a suffix 4 DC coil kit only.
On the above sizes only, when thespecial auxiliary package is mountedon the side of a contactor or starter,no standard auxiliary contact may bemounted on the same side.
Note: For NEMA Sizes 3 - 5 and IEC SizesL - S, special coil NCI clearing contact is anadd-on auxiliary (must mount on a basemount auxiliary contact; normally a 1NO).This arrangement will normally account fortwo of the three contact positions on theside of each contactor or starter.
DC Coil Elementary Diagramfor NEMA Sizes 1 - 3 and IEC Sizes G - N
Contactors and Starters
ImportantIncoming DC must be connectedbetween A1 and Top A2 Terminal.
A1Q
A2Top
Hold
Pick-Up•NOrL
NCI
AuxiliaryContact
A2 BottomDC Coil Elementary Diagramfor NEMA Sizes 00, 0, 4 & 5and IEC Sizes A - F & P - S
Contactors and Starters
Figure 33-9. Elementary DiagramsQ' 1NO available in Suffix 4 kits only.
Metal Mounting Plates Competitive Mounting Plates
' •' 8f W.Metal Mounting Plates
Table 33-47. Metal Mounting Plates —For Use on IEC Style Contactors, Startersand Overload RelaysApplication
ContactorsIEC Sizes A- FIEC Sizes G-KNon-reversing StartersIEC Sizes A- FIEC Sizes G-KOverload Relays '32A75AReversing StartersIEC Sizes A-FIEC Sizes G-KIEC Sizes L-NReversing ContactorsIEC Sizes A-FIEC Sizes G-KIEC Sizes L-N
CatalogNumber
C321MP1C321MP2
C321MP3C321MP4
C321MP5C321MP6
C321MP7C321MP12C321MP11
C321MP8C321MP9C321MP13
PriceU.S. S
10.1016.80
16.8027.00
10.1016.80
27.0040.2562.00
20.1027.0033.50
C321CMP1
The C321 adapter plates permit directreplacement of competitive starters withFreedom Series starters without drillingand tapping new mounting holes.
Table 33-48. Product SelectionDescription
FreedomSizes 00 and 0Freedom Size 1Freedom Size 2Freedom Size 3Freedom Size 4Freedom Size 5
Index Number :1
CatalogNumber
C321CMPO
C321CMP1C321CMP2C321CMP3C321CMP4
C321CMP5
PriceU.S. $
10.10
10.10
10.10
16.80
22.4028.00
Handling Number Only — Does not appearon product. The handling number isstamped on the carton label only.
I For use with DIN rail and base mountingadapters listed on Page 33-34.
Table 33-49. Competitive Starter ReplacementStarter to Be Replaced
Alien-Bradley 509, Cutler-Hammer A10®, Furnas 14,ESP100, General Electric CR206, CR306, Siemens SXL,Square D 8536, Westinghouse A200, B200
NEMASize
012345
Adapter KitCatalogNumber
C321CMPOC321CMP1C321CMP2C321CMP3C321CMP4C321CMP5
PriceU.S. S
10.1010.1010.1016.8022.4028.00
:4 Adapter not required for replacing Sizes 1, 4 and 5 A10 starters.
Table 33-50. Metal Mounting Plates — Approximate Dimensions and Shipping WeightsCatalogNumber
C321MP1C321MP2C321MP3C321MP4C321MP5C321MP6C321MP7C321MP8C321MP9C321MP11C321MP12C321MP13
Dimensions in Inches (mm)Wide
2.00 (50.8)2.56(65.0)1.80(45.7)2.56 (65.0)1.77(45.0)2.52 (64.0)4.20(106.7)4.20(106.7)5.66(143.8)8.70(221.0)5.71 (145.0)8.70(221.0)
High
3.88 (98.6)5.05(128.3)6.60(167.6)8.08 (205.2)4.63(117.6)5.14(130.6)7.38(187.5)4.35(110.5)5.05(128.3)
11.35(288.3)8.08 (205.2)7.17 (182.1)
Mounting
1.50x3.38(38.1x85.9)2.00 x 4.50 (50.8 x 114.3)6.07(154.2)®2.00x7.63(50.8x193.8)4.27(108.5)®2.00x4.59(50.8x116.6)3.50 x 6.87 (88.9 x 174.5)3.50 x 3.86 (88.9 x 98.0)5.25x3.63(133.4x92.2)7.00 x 10.81 (177.8 x 274.6) ''!'5.25x6.75(133.4x171.5)*7.00 x 6.63 (177.8 x 168.4) '»:
Ship Wt.Lbs. (kg)
.2(.1)
.4 (.2)
.7 (.3)
.6 (.3)
.3(.1)
.4 (.2)
.8 (.4)
.5 (.2)
.8 (.4)1.2 (.5)
.9 (.4)
.9 (.4)2-hole mounting.3-hole mounting.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C
F.T'N For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.201.01.T.E
33-28 NEMA Contactors & StartersDimensionsFreedom Line
Cutler-HammerJanuary 2001
Vol. 2, Ref. No. [0044]
Non-reversing StartersTable 33-56. Approximate Dimensions and Shipping Weights — Open TypeNEMASize
00-01-1P234
5678
Dimensions in Inches (mm)WideA
1.80(45.7)2.56 (65.0)2.56 (65.0)4.08(103.6)7.05(179.1)7.00(177.8)9.47 (240.5)
15.13(384.3)15.13(384.3)
HighB
6.60(167.6)7.08(179.8)8.08 (205.2)
11.35(288.3)12.06(306.3)17.77(451.4)21.69(550.9)29.13(739.9)34.50 (876.3)
DeepC
3.52 (89.4)4.44(112.8)4.44(112.8)5.94(150.9)7.25(184.2)7.76(197.1)9.90(251.5)
12.64(321.1)15.00(381.0)
MountingD
2.00 (50.8)2.00 (50.8)3.00 (76.2)6.00(152.4)6.00(152.4)3.10(78.7)
13.25(336.6)13.25 (336.6)
E
6.07(154.2)6.63(168.4)7.63(193.8)
10.81 (274.6)8.50(215.9)
16.00 (406.4)18.00 (457.2)21.25(539.8)16.75(425.5)
F
4.90(124.5)5.80(147.3)5.80(147.3)
—
G
.54(13.7)
.54(13.7)
.54(13.7)
—
Ship. Wt.Lbs. (kg)
2.2 (1.0)4.5 (2.0)4.7(2.1)
11.0(5.0)23.0(10.4)36.0(16.3)75.0(34.1)
120.0 (54.5)210.0 (95.3)
1
- Mtg. Holes for #10-32 Screws
Sizes 00 - 0 ©„ . -Mtg. Holes for
HD*] #10-32 ScrewsSizes 1 - 2
h— G---I I———C
^Aux.
Jl
it̂ SrU«— A-«-I^Mtg. Holes for (3)
e l § - i
m1/4-20 Screws
SizeS
Mtg. Holes for1/4-20 Screws
Size 4
TOO-1U—D—»J \- Mtg. Holes fo
1/4-20 ScrewsSize5
rc
Mtg. Holes for (4)3/8-16 Screws
Size 6
Mtg. Holes for1/2-13 Screws
Sizes 7-8
Figure 33-13. Approximate Dimensions® Holding circuit contact for Size 00 occupies 4th power pole position — no increase in width.
F.T-IU For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.201.01.T.E
PG.3.02.T.E
14-1
February 1999
Coil Data Notes
P.U. = Pick-up time is the average time taken from closing of the coil circuit to main con-tact touch.
D.O. = Drop-out time is the average time taken from opening of the coil circuit to main con-tact separation.
Cold = Coil data with a cold coil.
Hot = Coil data with a hot coil.
All data is based on a standard con-tactor with no auxiliary devices and a 120V AC or 24V DC magnet coil. Coil data has a ±5% range depend-ing on the application, therefore specific data may vary.
Standards and Certifications (Contactors and Starters)■
Standard: Designed to meet or exceed UL, NEMA, IEC, CSA, VDE and BS.
■
UL listed: UL File #E1491, Guide #NLDX — Open and NEMA 1, 4, 12 Enclosed
■
CSA Certified: CSA File #LR353, Class #321104 Open and NEMA 1 Enclosed
■
IEC: IEC 947-4-1, Sizes 6 – 8; IEC 158; IEC 947 Pending
Electrical Life — AC-3 and AC-4 Utilization Categories
Life Load Curves
Cutler-Hammer’s Freedom Series NEMA contactors have been designed and manufactured for superior life performance in any worldwide application. All testing has been based on requirements as found in NEMA and UL standards and conducted by Cutler-Hammer. Actual application life may vary depending on environmental condi-tions and application duty cycle.
Utilization Categories
AC-1 — Non-inductive or slightly inductive loads, such as resistance furnaces and heating.
AC-2 — Starting of slip-ring motors.
AC-3 — Squirrel cage motors; starting, switching off motors during running.
AC-4 — Squirrel cage motors; start-ing, plugging, inching or jogging.
NOTE: AC-3 tests are conducted at rated device currents and AC-4 tests are conducted at six times rated device currents. All tests have been run at 460V, 60 Hz.
Contactor Choice
■
Decide what utilization category your application is and choose the appropriate curve.
■
Locate the intersection of the life-load curve of the appropriate contactor with the applications operational current (Ie), as found on the horizontal axis.
■
Read the estimated contact life along the vertical axis in number of operational cycles.
Technical DataFreedom NEMA
Table of Contents
Description Page
Freedom NEMA
. . . . . . . . . . . . . 14-1
Freedom Heater
Pack Selection
. . . . . . . . . . . . . . 14-4
Advantage
. . . . . . . . . . . . . . . . . 14-7
Advantage
Overload Settings
. . . . . . . . . . . 14-9
Freedom IEC
. . . . . . . . . . . . . . . 14-12
Control Power
Transformer Selection
. . . . . . . 14-17
AF91
. . . . . . . . . . . . . . . . . . . . . . 14-19
Vacuum Break
. . . . . . . . . . . . . . 14-21
Ampere Rating
of AC Motors
. . . . . . . . . . . . . . . 14-22
100,000,000
10,000,000
1,000,000
100,000
Op
erat
ion
s
810 162054 108 162 270 54010,0001000100
Break Amperes
101
100,000,000
10,000,000
1,000,000
100,000
Op
erat
ion
s
189 27 45 90 135 2701000100
Break Amperes
NEMA AC-4 Load Life — Sizes 00 – 5, 480V 60 Hz
NEMA AC-3 Load Life — Sizes 00 – 5, 480V 60 Hz
101
Size00 Size
0
Size1 Size
2 Size3
Size5
Size4
Size00
Size0
Size2
Size3
Size5
Size4
Size1