C:UserskalgillfaciDocuments914285 Ashton Bus Station...
Transcript of C:UserskalgillfaciDocuments914285 Ashton Bus Station...
maintenance walkway
single ply roofingmembrane
photovoltaic solar panelsto proposed canopy roof
ETFE rooflights toentrance lobby
ETFE rooflights tocentral open space
maintenance walkway
white painted polyesterpowder coated fascia
green roof
lowergreen roof
primary canopy roofaccess
safety balustrade setback from roof edge toreduce visual impact
safety balustrade setback from roof edge toreduce visual impact
Roof over secondfloor store room /access to roof level
single ply membraneroof
Secondary roof access
Revision Notes:R04 - Roof over lift and Faith roomextendedR05 - First floor added over block 2R06 - Access hatch added in roof overPlant room.
R04
R05
R06
19 m²faith room
TF.01
19 m²TfGM manager
TF.04
22 m²TfGM comms. room
TF.0539 m²
mixed driver's restTF.06
11 m²Stagecoach paying in
TF.12
11 m²Stagecoach manager
TF.09
41 m²TfGM plant room
TF.13
4 m²male acc. WC
TF.08
49 m²tenant plant room
TF.15
35 m²corridorTF.03
25 m²Stagecoach supervisor
TF.11
4 m²female acc. WC
TF.07
4 m²wc
TF.10
12 m²stair 2TF.16
lift
lowergreen roof
canopy overconcourse
canopy overconcourse
canopy overconcourse
canopy over frontentrance
access to lower rooffrom first floor level
Revision Notes:R01 - External walls enclosing lift andfaith room extended.R02 - Internal layout amended.R03 - First Floor level added.
R02
R01
R03
Drawings and models powered byAustin-Smith:Lord LLP BIM using AutoDesk Revit
Austin-Smith:Lord LLPArchitects Designers PlannersLandscape ArchitectsPort Of Liverpool BuildingPier Head, LiverpoolL3 1BYt +44 (0)151 227 1083.e [email protected]
DO NOT SCALE. Use figured dimensions only.The contractor is requested to check alldimensions before the work is put in hand.©All copyrights Austin-Smith:Lord LLP
This drawing must only be used for the purposefor which it is supplied and its contents must notbe reproduced for any purpose without writtenpermission.No areas indicated, or areas calculated from thisdrawing should be used for valuation purposesor as the basis for development contracts.Austin-Smith:Lord LLP is a limited liabilitypartnership registered in England & Wales.Number OC315362
Project
Description
Job No. Drawing No. Revision
Date
Drawn
Scale @ A1
Status
R
PLANNING C
1 : 200
Transport for Greater Manchester - Tameside Interchange
Proposed First Floor & Canopy Level Plans
914285 L(--)202
LL
10/06/2015
Revision Description By Chkd By Date
* First Floor - General design development with topographicalsurvey
LL KGF 15/07/17
A First Floor - Planning LL KGF 15/10/19B First Floor - Planning Submission LL KGF 15/11/25C Re-issued to Planning following RIBA Stage 4 KGF LL 16/05/26
First Floor Plan
Roof Plan