CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

16
Catalog 2019 CURRENT TRANSFORMERS ROGOWSKI COIL

Transcript of CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

Page 1: CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

Catalog 2019

CURRENT TRANSFORMERS ROGOWSKI COIL

Page 2: CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

WHO WE ARE and WHAT WE DO

We provide instrumentation and sensors for measurements on plants, machine tools, buildings and wherever there is the need to acquire and monitor processes and energy

consumption.

The best solutions are the simplest ones, just have the right tools ...

PECTECH distributes interfaces for automation, devices and solutions for the measurement, monitoring and analysis of your energy consumption. We have available in stock a wide choice of split core and solid core current transformers, Rogowski probes that can be matched to your network analyzers, or you can get the best solutions from

our experts. PECTECH’s ability to discover new products on the international market, in order to meet

new needs in new markets, allows us to always be one step ahead.

PECTECH also manages in stock :

• MID certified energy meters in single-phase version with direct insertion, three-phase with direct insertion or with external CT, all with RS485 Modbus RTU serial communication. • Ultra compact network analyzers with universal CT input and serial communication.• Network analyzers for OEM market, low cost, with integrated serial communication. • AC/DC Current Transformers.• Modules for monitoring electrical parameters such as: phase loss, wrong sequence or phase failure, phase unbalance, over or under current, over or under load, over or under frequency and over or under voltage, voltage and power monitoring.

Each measure requires an instrument ...

Devices that are easy to install and ready to be connected by serial port are the strengths of our commercial proposal.

Page 3: CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

- Supported by all the Energy meters with 5A secondary input;- Allow a not invasive installation;- Suitable for retrofit and energy monitoring activities;- Hole window 24mm for current up to 300 A;- Hole window 36mm for current from 300 A up to 600 A

We recommend the version with 333mV secondary for installations distant from the analyzer

SPLIT CORE CURRENT TRANSFORMERSHole window 24mm / 36mm

SCT

Primary Current Overload Accuracy on the

range 5-120%Burden VA- Cl.1 Order Code

100 A 160 A ≤1.5% 1,5 SCT-24-100/5

200 A 320 A ≤1% 1,5 SCT-24-200/5

300 A 500 A ≤1% 1,5 SCT-24-300/5

Secondary terminals : 1 mt cable integrated ( 18AWG Red and Black lead wire)Standard : IEC60044-1Rated Voltage : 0,66kVIsolation Voltage: 2kVRated Frequency : 50/60 HzOperating Temperature : -15°C...45°C

Primary Current Overload Accuracy on the

range 5-120%Burden VA-Cl.1 Order Code

300 A 540 A ≤0.5% 1,5 SCT-36-300/5

400 A 720 A ≤0.5% 1,5 SCT-36-400/5

600 A 960 A ≤0.5% 1,5 SCT-36-600/5

24mm Version 36mm Version

SECONDARY @ 5A

SCT-24

SCT-36 Secondary terminals : 1 mt cable integrated ( 18AWG Red and Black lead wire)Standard : IEC60044-1Rated Voltage : 0,66kVIsolation Voltage: 2kVRated Frequency : 50/60 HzOperating Temperature : -15°C...45°C

3

Page 4: CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

- Easy to install and cheap;- Suitable for retrofit and energy monitoring activities;Hole window 10mm for current up to 50 A;Hole window 16mm for current up to 200 A; Hole window 24mm for current up to 300 A;Hole window 36mm for current up to 600 A.

Suggested for installations distant from the analyzer

SCT

Secondary terminals : 1 mt cable integrated Isolated plastic case recognized according to UL94-V0Isolation category: CAT III Protection level : 7.5V0-PRated frequency : 50/60 Hz Operating temperature : -20°C...50°CAccuracy (range 5-120%) : 0,5/1 %

SECONDARY @ 333mV

Primary Current

Max Current

Accuracy class Order Code

5 A 80 A 1 SCT-10-5/333

30 A 80 A 1 SCT-10-30/333

50 A 80 A 1 SCT-10-50/333

Primary Current

Max Current

Accuracy class Order Code

80 A 240 A 0,5 SCT-16-80/333

100 A 240 A 0,5 SCT-16-100/333

200 A 240 A 1 SCT-16-200/333

Primary Current

Max Current

Accuracy class Order Code

100 A 480 A 0,5 SCT-24-100/333

200 A 480 A 0,5 SCT-24-200/333

300 A 480 A 0,5 SCT-24-300/333

Primary Current

Max Current

Accuracy class Order Code

300 A 720 A 0,5 SCT-36-300/333

400 A 720 A 0,5 SCT-36-400/333

600 A 720 A 0,5 SCT-36-600/333

SCT-10

SCT-16

SCT-24

SCT-36

SPLIT CORE CURRENT TRANSFORMERSHole window 10mm / 16mm / 24mm / 36mm

4

Page 5: CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

- Easy to install and cheap;- Suitable for retrofit and energy monitoring activities;- complete opening interlocking- 2mt of integrated cable

Suggested for installations distant from the analyzer

SCT

Primary Current

Max Current

Accuracy class Order Code

100 A 300 A 0,5 SCT-19-100/333

200 A 300 A 0,5 SCT-19-200/333

300 A 400 A 1 SCT-19-300/333

SCT-19

SECONDARY @ 333mV

SPLIT CORE CURRENT TRANSFORMERSSquare Hole window 19x19mm

Secondary terminals : 2 mt cable integrated Isolated plastic case recognized according to UL94-V0Isolation category: CAT III Work Voltage: 660VRated frequency : 50/60 Hz Operating temperature : -20°C...70°CAccuracy (range 5-120%) : 0,5/1 % Linearity: <0,2%Weight: 90 gr.

5

Page 6: CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

BUSBAR SPLIT CORE CURRENT TRANSFORMERS

Primary Current

Cl. 0,5VA

Cl. 1VA

Cl. 3VA

Order code

100 A - - 1,5 DBP23-100/5

200 A - 1,5 2,5 DBP23-200/5

300 A 1,5 4 6 DBP23-300/5

400 A 2,5 6 10 DBP23-400/5

Busbar window 20x30mmSecondary terminals : Dual M4 ScrewsBuilt-in Terminal coversHousing Material Self extinguishing Nylon IEC185 classification VO according to UL-94Weight : 0.75Kg

Busbar window 50x80mmSecondary terminals : Dual M4 ScrewsBuilt-in Terminal coversHousing Material Self extinguishing Nylon IEC185 classification VO according to UL-94Weight : 0.9 Kg

Primary Current

Cl. 0,5VA

Cl. 1VA

Cl. 3VA

Order code

300 A 1,5 3 6 DBP58-300/5

400 A 1,5 3 10 DBP58-400/5

600 A 2,5 5 15 DBP58-600/5

800 A 3 7,5 20 DBP58-800/5

1000 A 5 10 20 DBP58-1000/5

Busbar window 80x80mmSecondary terminals : Dual M4 ScrewsBuilt-in Terminal coversHousing Material Self extinguishing Nylon IEC185 classification VO according to UL-94Weight : 1,05 Kg

Primary Current

Cl. 0,5VA

Cl. 1VA

Cl. 3VA

Order code

300 A 1,5 3 6 DBP88-300/5

400 A 1,5 3 10 DBP88-400/5

500 A 2,5 5 15 DBP88-500/5

600 A 2,5 5 15 DBP88-600/5

800 A 3 7,5 20 DBP88-800/5

DBP

SECONDARY @ 5A

DBP-23

DBP-58

DBP-88

6

Page 7: CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

Busbar window 80x120mmSecondary terminals : Dual M4 ScrewsBuilt-in Terminal coversHousing Material Self extinguishing Nylon IEC185 classification VO according to UL-94Weight : 1,25 Kg

Primary Current

Cl. 0,5VA

Cl. 1VA

Cl. 3VA

Order code

600 A - 5 15 DBP812-600/5

800 A 3 7,5 20 DBP812-800/5

1000 A 5 10 20 DBP812-1000/5

1200 A 6 12,5 25 DBP812-1200/5

1500 A 8 17 30 DBP812-1500/5

2000 A 8 17 30 DBP812-2000/5

Busbar window 80x160mmSecondary terminals : Dual M4 ScrewsBuilt-in Terminal coversHousing Material Self extinguishing Nylon IEC185 classification VO according to UL-94Weight : 3,5 Kg

Primary Current

Cl. 0,5VA

Cl. 1VA

Cl. 3VA

Order code

2000 A 15 20 25 DBP816-2000/5

2500 A 15 20 25 DBP816-2500/5

3000 A 20 25 30 DBP816-3000/5

4000 A 20 25 30 DBP816-4000/5

5000 A 20 25 30 DBP816-5000/5

6000 A 20 25 30 DBP816-6000/5

BUSBAR SPLIT CORE CURRENT TRANSFORMERSSECONDARY @ 5A

DBP

DBP-812

DBP-816

7

Page 8: CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

-3-2-1

TECHNICAL FEATURES TRANSDUCER O.D (coil cross section) 12mm TRANSDUCER LENGHT 300, 400, 500, 600, 700mm (other on request) CAP COUPLING O.D. 17mm (max) MAX DIAMETER OF CONDUCTOR OR BUS BAR RC-12-300 : 84mmRC-12-400 : 115mmRC-12-500 : 147mmRC-12-600 : 179mmRC-12-700 : 211mm MATERIALS Thermoplastic Rubber, flame retardant UL94 V0 rated ENVIROMENTAL CONDITIONS: WORKING TEMPERATURE -20°C...+70°C RELATIVE HUMIDITY 85% max without condensation POLLUTION DEGREE 2 MAXIMUM ALTITUDE 2000 m ELECTRICAL DATA : MAXIMUM MEASURABLE CURRENT 100kA @ 50/60Hz ACCURACY +/- 1% LINEARITY +/- 0,2 % OUTPUT SIGNAL 100mV/ 1000A @ 50Hz FREQUENCY RANGE 20Hz... 5 KHz POSITION SENSITIVITY : MEASURED BUS +/- 2% maximum on closing unit EXT. FIELD INFLUENCE +/-0,5% maximum TEMPERATURE SENSITIVITY +/- 0,07% per °C SAFETY: WORKING VOLTAGE MAX 1000V @ 50/60Hz ( CAT III) HI POT TEST (Transducer & Output Cable) 7400 Vac @ 50/60 Hz for a minute.

RC-12-xxx

• Current measurement up to 100kA;• Calibration @ 1%;• Suitable for critical space installations inside small panels, for retrofit, revamping, all energy monitoring activities;• Easy to install, pratical clamp connector;• Customizable lenght and colors;• Must to be used with an Integrator (within the Power meter or external).

Ø12mm Flexible Rogowski coils

8

Page 9: CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

-3-2-1

What is a Rogowski coil?

Rogowski coils have been used for the detection and measurement of electric currents for decades. They are based on a simple principle: an “air-cored” coil is placed around the conductor in a toroidal fashion, the magnetic field produced by the current induces a voltage in the coil. The voltage output is proportional to the rate of change of current. This voltage is integrated, thus producing an output proportional to the current.

By using precision winding techniques, especially developed for the purpose, the coils are manufactured so that their output is not influenced by the position of the conductor within the toroid, and to reject interference from external magnetic fields caused, for example, from nearby conductors.Basically, a Rogowski coil current measuring system consists of a combination of a coil and conditioning electronics. Rogowski coil current transducers are used for the AC measurement.

They can be used in similar circumstances to current transformers but for many applications they haveconsiderable advantages:•Widedynamicrange.•Highlinearity.•Veryusefulwithlargesizeorawkwardshapedconductorsorinplaceswithlimitedaccess.Thankstothe structure without hard core, the coil can be easily manufactured according to the application or to the available space.•Unliketraditionalcurrenttransducers,thereisnodangerfromopen-circuitedsecondaries.•Theycannotbedamagedbylargeoverloads.•Theyarenon-intrusive.Theydrawnopowerfromthemaincircuitcarryingthecurrenttobemeasured.•Theyarealsolightweightedandinsomeapplicationsarelightenoughtobesuspendedontheconductor being measured.

RC-12-xxx

9

Page 10: CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

-3-2-1

Ø6 Flexible Rogowski coil fixed by cable ties

TECHNICAL FEATURES TRANSDUCER O.D (coil cross section) 6 mm WEIGHT Approx 100 gr COIL RESISTANCE from 100 to 300 Ω or 1.5kΩ 100A MAX CURRENT MEASURABLE 100kA @ 50/60Hz LEAD LENGHT 2 meters OUTPUT (CALIBRATED) 50mV/kA@50Hz±0.5% or 60mV/kA@60Hz±0.5% READ ACCURACY Calibrated <0.5% (central position, 25°C) TEMPERATURE DRIFT 400 ppm/°C POSITION ERROR ±1% maximum OUTPUT on 0 A (zero drift) ≤1mV PHASE ERROR ≤0.5° LINEARITY ±0.2% of reading BANDWIDTH 1Hz to 1MHz (-3dB) OPERATING TEMPERATURE -30°C to 80°C STORAGE TEMPERATURE -40°C to 90°C FREQUENCY RANGE 20Hz... 5 KHz

• Calibrated to 0.5%• 6mm section make more stable• Easy to fixed on bus-bar or cable by cable ties• Very competitive price

MAIN FEATURES :- High linearity up to 1000 A;- Wide dynamic range;- Very useful with large size or awkward shaped conductors or in places with limited access;- No danger from open-circuited secondary;- Not damaged by large overloads;- Non-intrusive, no power drawn from the main;

MATERIALS COIL & CABLE Thermoplastic rubber flame retardant UL 94 V-0 rated COUPLINGS PA6 UL 94 V-O rated SHIELDED 100% coil, 100% output cable SAFETY STANDARDS CE marked - Complies with EMC EN 61326-1 2006 VOLTAGE INSULATION Coil : 1000 V ; Signal cable : 1000 V SAFETY 1000V CATIII , 600V CAT IV

RC-MINI-6-36

10

Page 11: CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

-3-2-1

DIMENSIONS (mm)

A : Window size 36

B : Window size 37

C : Coil O.D. 48

D : Coil section 6

E : Lead cable total 2000

F : Coil lenght 130

POSITION SENSITIVITY

Conductor Position Typical Error (%)

Adjacent to the clip together mechanism <0,5 %

Adjacent to the inside coil edge <0,8 %

Adjacent to the opposite clip <1 %

RC-MINI-6-36 is a MINI flexible current transducer based on Rogowski principle. They can be used in all those applications, in which traditional transducers are not fitting due to its size and/or weight.

Due to its specific features, flexible Rogowski coil is an extremely confortable solution for current measurement and can be used in a number of cases where traditional current transducer is not the adequate solution.RC-MINI-6-36 coil is provided with a shield against the influence of external magnetic fields, therefore it grants a stable measurement from low currents to hundreds of A.

The Rogowski coils must be connected to an electronic integrator for 90° phase shift compensation and frequency equalization.

Rogowski Coil RC - MINI ( version) - 6 (mm) - 36 (hole diameter mm)Available only in Orange

RC-MINI-6-36

11

Page 12: CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

SOLID CORE CURRENT TRANSFORMERS

Primary Current

Cl. 0,5VA

Cl. 1VA

Order code

50 A - - CT-50/5-1

100 A - 1,5 CT-100/5-1

150 A 1,5 4 CT-150/5-1

CT

SECONDARY @ 5A

CT-xxx/5-1

Primary @ 60A and 80A available on request.

CT-xxx/5-2 Primary Current

Cl. 0,5VA

Cl. 1VA

Order code

200 A 1,5 3 CT-200/5-2

300 A 1,5 3 CT-300/5-2

CT-xxx/5-3 Primary Current

Cl. 0,5VA

Cl. 1VA

Order code

300 A 4 6 CT-300/5-3

500 A 6 10 CT-500/5-3

800 A 8 15 CT-800/5-3

1000 A 10 20 CT-1000/5-3

CT-xxx/5-1 dimensions

CT-xxx/5-3 dimensionsCT-xxx/5-2 dimensions

TECHNICAL FEATURES

ENCLOSURE ABS Self-extinguishing case

CURRENT TO THE SECONDARY 5 A (other on request)

WORKING FREQUENCY 40-60 Hz

DYNAMIC NOMINAL CURRENT OF SHORT CIRCUIT (Idin) 2,5 I ter per 1 sec - Max peak value that the CT can bear having the secondary in short circuit

THERMAL NOMINAL CURRENT OF SHORT CIRCUIT (Iter) 40-80 Ipn per 1 sec - Max effective value with secondary in short circuit

STANDING OVERCURRENT 1,2 In

VOLTAGE INSULATING REFERENCE 0,72kV maximum Voltage value

TESTING VOLTAGE 3kV at 50 Hz per 1 min., max voltage value, between primary and secondary

SAFETY VALUE N <= 5Saturation Factor (Sf ) or ratio between primary current value (that cause the magnetic core saturation), and the nominal current value. The lower is the N value the higher is the instrument protection

WORKING TEMPERATURE -25°...+50°C

STORAGE TEMPERATURE -40°...+80°C

MAX TEMP OF THE PASSING CABLE 70°C

RELATIVE HUMIDITY 90% max, not condensing

INSULATION on air, E class

PROTECTION DEGREE IP 30

CONSTRUCTION Standard CEI 38-1, IEC 185, VDE 0414, EN60044-1, EN60044-1A

12

Page 13: CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

Primary Current

Cl. 0,5VA

Cl. 1VA Order code

50 A - 1,5 CT-50/5-11

100 A 2,5 2,5 CT-100/5-11

150 A 2,5 5 CT-150/5-11

200 A 5 5 CT-200/5-11

300 A 5 5 CT-300/5-11

BUSBAR CURRENT TRANSFORMERSSECONDARY @ 5A

CT

CT-xxx/5-11

TECHNICAL FEATURES

ENCLOSURE ABS Self-extinguishing case

CURRENT TO THE SECONDARY 5 A (other on request)

WORKING FREQUENCY 40-60 Hz

DYNAMIC NOMINAL CURRENT OF SHORT CIRCUIT (Idin) 2,5 I ter per 1 sec - Max peak value that the CT can bear having the secondary in short circuit

THERMAL NOMINAL CURRENT OF SHORT CIRCUIT (Iter) 40-80 Ipn per 1 sec - Max effective value with secondary in short circuit

STANDING OVERCURRENT 1,2 In

VOLTAGE INSULATING REFERENCE 0,72kV maximum Voltage value

TESTING VOLTAGE 3kV at 50 Hz per 1 min., max voltage value, between primary and secondary

SAFETY VALUE N <= 5Saturation Factor (Sf ) or ratio between primary current value (that cause the magnetic core saturation), and the nominal current value. The lower is the N value the higher is the instrument protection

WORKING TEMPERATURE -25°...+50°C

STORAGE TEMPERATURE -40°...+80°C

MAX TEMP OF THE PASSING CABLE 70°C

RELATIVE HUMIDITY 90% max, not condensing

INSULATION on air, E class

PROTECTION DEGREE IP 30

CONSTRUCTION Standard CEI 38-1, IEC 185, VDE 0414, EN60044-1, EN60044-1A

CT-xxx/5-12 Primary Current

Cl. 0,5VA

Cl. 1VA Order code

300 A - 1,5 CT-300/5-12

400 A 2,5 2,5 CT-400/5-12

600 A 2,5 5 CT-600/5-12

800 A 5 5 CT-800/5-12

1000 A 5 5 CT-1000/5-12

CT-xxx/5-11CT-xxx/5-12

DIN RAIL MOUNTING TOOLS

13

Page 14: CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

Primary Current

Cl. 0,5VA

Cl. 1VA Order code

500 A 10 10 CT-500/5-13

600 A 10 10 CT-600/5-13

800 A 10 20 CT-800/5-13

1000 A 10 20 CT-1000/5-13

1200 A 10 30 CT-1200/5-13

BUSBAR CURRENT TRANSFORMERSSECONDARY @ 5A

CT

CT-xxx/5-13

CT-xxx/5-14Primary Current

Cl. 0,5VA

Cl. 1VA Order code

800 A 10 20 CT-800/5-14

1000 A 10 20 CT-1000/5-14

1200 A 10 30 CT-1200/5-14

1500 A 10 30 CT-1500/5-14

2000 A 10 30 CT-2000/5-14

Primary Current

Cl. 0,5VA

Cl. 1VA Order code

1000 A 15 20 CT-1000/5-15

1200 A 15 30 CT-1200/5-15

1500 A 30 30 CT-1500/5-15

2000 A 30 45 CT-2000/5-15

2500 A 30 45 CT-2500/5-15

3000 A 45 45 CT-3000/5-15

4000 A 45 45 CT-4000/5-15

CT-xxx/5-15

14

Page 15: CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

AC/DC SPLIT CORE CURRENT TRANSFORMERSHOLE DIAMETER 21mm / 41mm

SCTHSCTHALL’s EFFECT SENSOR

HSCT-21 / HSCT-41NOMINAL CURRENT MEASUREMENT HSCT-21-4V-50 : 50 A AC/DC / HSCT-41-4V-200: 200 A AC/DC

HSCT-21-4V-100: 100 A AC/DC / HSCT-41-4V-500: 500 A AC/DC

AUXILIARY POWER SUPPLY ± 12 … 15 V dcWORKING FREQUENCY From DC up to 20 kHz

LOAD RESISTANCE Min 10 kOhm

ABSORPTION @ 15 V dc 25mA

VOLTAGE OUTPUT @ Nominal current Ip = 0 ± 25 mV

VOLTAGE OUTPUT @ Nominal current Ipn ± 4 V ±1%

ACCURACY +/- 1%

LINEARITY < 1%

THERMAL DRIFT ± 1 mV/°C

RESPONSE TIME 0...90% 10 µs

ISOLATION PRIMARY/SECONDARY 3 kV

WORKING TEMPERATURE -25°C...85°C

STORAGE TEMPERATURE -40°C...100°C

CONNECTION Removable Connector for cable section 0,2 ÷ 2,5 mm2

WEIGHT HSCT-21: 80 gr. / HSCT-41: 300 gr.

The HSCT series sensors allow the measurement of continuous and alternating currents with excellent precision and a wide measuring range.Using the open loop Hall effect measurement technique, they allow the use of an openable core, making the sensors easily installable without disconnecting the conductors. Extractable screw terminals make installation extremely convenient.

HSCT sensors are used in all measuring requirements for continuous and variable frequency currents (up to 20 kHz). For example for battery control systems (energy storage, UPS, safety power supplies), variable speed drives, power supply groups, radio stations, power electronics, etc.The output signals can be connected to specific instruments, PLCs, etc.

Ip: Primary CurrentIpn: Nominal Primary Current0 V: measurement reference and auxiliary power supplyV+: Positive auxiliary power supply +12…15VV-: Negative auxiliary power supply -12…15VVout: Nominal output ±4 V

15

Page 16: CURRENT TRANSFORMERS ROGOWSKI COIL - Pectech

w w w . p e c t e c h . i t info@pec tech. i tSales depar tment. . . . . . . . . . . . . sa les@pec tech. i t

v ia Cà R as i , 9/P - 35142 Padova (PD) , I ta ly

Ph. +39 049 4906494VAT : IT05183250280REA Registro I mprese: PD 449595Capita le socia le € 10.000 i .v.Società Unipersonale

FEBRUARY 2019

Distributed by:

SRL