Cummins C3000D5
-
Upload
nicholas-frye -
Category
Documents
-
view
180 -
download
4
description
Transcript of Cummins C3000D5
![Page 1: Cummins C3000D5](https://reader036.fdocuments.us/reader036/viewer/2022071700/552b855b550346d6478b471f/html5/thumbnails/1.jpg)
C3000 D5
50
Diesel
Our energy working for you.™
1/4 1/2 3/4 Full 1/4 1/2 3/4 Full
39.3 68.3 97.8 128.7 35.6 63.5 90.5 118.9
178.73 310.90 445.07 585.80 162.07 289.10 411.70 541.10
Standby rating
Combustion air, m3/min
Prime
kVA (kW)
2750 (2200)
Standby
kVA (kW)
3000 (2400)
2617
2304
15.5:1
190
1500
Overspeed limit, rpm
BMEP at set rated load, kPa
Regenerative power, kW
Cummins
Prime rating
170
QSK78 - G9
Cast Iron, 60° V18 cylinder
Turbo Charged and Low Temperature After-cooled
2375
2539
Configuration
Aspiration
Bore, mm
Gross engine power output, kWm
Governor type
Starting voltage
Maximum fuel inlet temperature (°C)
Maximum fuel inlet restriction, mm Hg
2225
193.00
Engine model
Piston speed, m/s
Compression ratio
Maximum air cleaner restriction, kPa
Fuel consumption
9.5
Ratings
Stroke, mm
Rated speed, rpm
Load
gph
L/hr
EngineEngine manufacturer
Air
Fuel flow
70
127
413
Electronic
24 Volts DC
1850 ±50
189
Lube oil capacity, L
Maximum fuel flow, L/hr
186.00
©2010 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others.
6.22
Model:Frequency:Fuel Type:
» Generator set data sheet
Transient data sheet: TD50-HHP
DD50-OSHHP/DD50-CSHHP
Spec sheet:
Noise data sheet (Open/enclosed):
Airflow data sheet:
Derate data sheet (Open/enclosed):
SS18-CPGK
ND50-OSHHP/ND50-CSHHP
AF50-HHP
![Page 2: Cummins C3000D5](https://reader036.fdocuments.us/reader036/viewer/2022071700/552b855b550346d6478b471f/html5/thumbnails/2.jpg)
Standby
Prime
Open Enclosed
Dimensions
Enclosed set
Coolant capacity (with radiator), L
6.8
Genset outline
432Exhaust gas flow at set rated load, m3/min
Fan load, KWm
Cooling system air flow, m3/sec @ 12.7mmH2O
RTF
Exhaust
RTF
Note: Standard open genset options running at 400V, 150m above sea level. For enclosed product derates, please refer to datasheet - DD50-CSHHP.
RTF
45°C
Maximum exhaust back pressure, kPa
RTF
RTF2965 (2372)
422Exhaust gas temperature, °C
40°C
Ambient design, °C
Standard set-mounted radiator cooling
Maximum cooling air flow static restriction mmH2O
27°C
--
Width
* Weights represent a set with standard features. See outline drawing for weights of other configurations
Unit wet weight kgs
Unit dry weight kgs
427
HeightLength
19996
3000 (2400) 3000 (2400)
RTF
Open set derating factors kVA (kW)
3000 (2400)
Total heat rejection, BTU/min
For 380V product derates, please consult the factory for details.
50°C 55°C
Prime rating
RTF
415
RTF
RTF
Standby rating
2750 (2200)
--
Weights*
2670 (2136)2750 (2200)2750 (2200)
20616
Open set
Outlines are for illustrative purposes only. Please refer to the genset outline drawing for an exact representation of this model.
©2010 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others.
Enclosed set standard dimensions
Standard open set dimensions 23002313
-- --
5668
--
![Page 3: Cummins C3000D5](https://reader036.fdocuments.us/reader036/viewer/2022071700/552b855b550346d6478b471f/html5/thumbnails/3.jpg)
Feature code
-- -- -- --
Formulas for calculating full load currents:
Single phase outputThree phase output
Alternator data
Web: www.cumminspower.comE-Mail: [email protected]: +44 (0) 1843 255902Telephone: +44 (0) 1843 255000
Manston Park, Columbus AvenueManston, Ramsgate Kent CT12 5BF, UK
See your distributor for more information.
Duty2
Cummins Power Generation
©2010 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others.
Wye, 3 Phase
Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. Emergency Standby Power (ESP) is in accordance with ISO 8528. Fuel Stop power in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514.
Emergency Standby Power (ESP)
Limited-Time running Power (LTP):
Applicable for supplying power to a constant electrical load for limited hours. Limited Time Running Power (LTP) is in accordance with ISO 8528.
HVS1804S,T,W,XS/P/C HVS1804S,T,W,XS/P/C 6600V
Ratings definitions
3300V
VoltageAlternator
80-125C 11000V
Base Load (Continuous) Power (COP)
Applicable for supplying power continuously to a constant electrical load for unlimited hours. Continuous Power (COP) in accordance with ISO 8528, ISO 3046, AS 2789, DIN 6271 and BS 5514.
Prime Power (PRP)
Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528. Ten percent overload capability is available in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514.
S/P/C
Temp rise degrees C
MVS1804R,S,T,W380-440VS/P/C
Connection1
LVS1804S,T,W,XWye, 3 PhaseWye, 3 Phase
80-150CWye, 3 Phase
80-125C80-150C
73x0.8Voltagex1.
kWx1000
Voltage
x1000haseFactorkWxSingleP